Letter Sequence Other |
|---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance...
- Supplement, Supplement, Supplement
Results
Other: ML21053A071, ML21197A137, ML21197A139, ML22020A389, ML22132A272, ML22144A183, ML22144A196, ML22221A195, ML22221A199, ML22294A190, ML22339A140, ML23026A325, ML23033A672, ML23086C025, ML23101A185
|
MONTHYEARML21053A0712020-11-19019 November 2020 Redacted_Application Cover Letter (ML20325A194) Project stage: Other ML21062A2502021-03-11011 March 2021 GE-Hitachi Nuclear Energy Americas, LLC - Receipt and Supplemental Information Needed for Renewal Review of GE-Hitachi Nuclear Energy Americas, LLC Nuclear Test Reactor Facility Operating License No. R-33 Project stage: Approval ML21197A1392021-07-26026 July 2021 GE-Hitachi Nuclear Energy of Americas LLC - Regulatory Audit the Reactor Description, Radiation Protection, and Accidental Analysis in the Operating License Application Project stage: Other ML21197A1212021-07-26026 July 2021 73-Audit Plan-Rx and Accident Analysis (July 2021) Project stage: Request ML21197A1372021-07-26026 July 2021 Office of Nuclear Reactor Regulation Regulatory Audit Topics Regarding the Reactor Description, Radiation Protection, and Accident Analysis Described in the Application for License Renewal License No. R-33 General Electric Hitachi Nuclear E Project stage: Other ML21265A2472021-09-22022 September 2021 GEH - Supplemental Information Supporting GE Nuclear Test Reactor License Renewal Audit Questions and Responses Project stage: Supplement ML21337A2572021-12-0303 December 2021 GE Hitachi Nuclear Energy, Requalification Program for the General Electric Nuclear Test Reactor - December 2021 Project stage: Request ML22014A4202021-12-16016 December 2021 73-GEH PSP Cover Letter for 12-16-2021 Submittal (U) Project stage: Request ML22020A3892022-02-0808 February 2022 GE Hitachi Nuclear Energy Americas, LLC Approval of the Revised Operator Requalification Program for the Nuclear Test Reactor Project stage: Other ML22055A6222022-02-24024 February 2022 GE-Hitachi Nuclear Energy Americas, LLC, Vallecitos Nuclear Center (Vnc) Radiological Emergency Plan (REP) Revision Project stage: Request ML22132A2722022-04-0404 April 2022 2022-04-04 Mjf 22-002 M220058 Security Plan PSP RAI Cover Project stage: Other ML22112A2362022-04-22022 April 2022 GE-Hitachi Nuclear Energy Americas, LLC, Response to Request for Additional Information for Nuclear Test Reactor License Renewal Application Project stage: Request ML22144A1962022-05-26026 May 2022 GE-Hitachi Nuclear Energy Americas LLC - Approval of the Revised Physical Security Plan for the Vallecitos Nuclear Center Project stage: Other ML22144A1832022-05-26026 May 2022 73-GEH LRA Acceptability for Review (Supplement Provided) Project stage: Other ML22221A1952022-08-10010 August 2022 Djh 22-004 M220XXX GEH Ntr TS (Nedo 32765, Rev 4) Project stage: Other ML22221A1992022-08-10010 August 2022 GEH LRA Audit Ntr (R-33) Technical Specifications - Nedo 32765, Rev 4 Project stage: Other ML22258A1182022-09-15015 September 2022 GE Hitachi Nuclear Energy - Response to Request for Public Docketing of Information Relating to GE Nuclear Test Reactor License Renewal Project stage: Request ML22294A1902022-10-28028 October 2022 GE-Hitachi Nuclear Energy Americas Llc—Request for a Section 106 Review Under the National Historic Preservation Act for the Proposed Renewal of Facility Operating License No. R-33 for the Nuclear Test Reactor Project stage: Other ML22339A1412023-01-0303 January 2023, 4 January 2023 Package-GEH FRN for Acceptability for Docketing Project stage: Request ML22339A1402023-01-0303 January 2023 73 GE License Renewal Application Notice of Acceptability for Docketing Letter Project stage: Other ML23026A3252023-01-27027 January 2023 GE-Hitachi Nuclear Energy Americas, LLC - Report on the Regulatory Audit Nuclear Test Reactor Technical Specifications in Support of the License Renewal Application Review Project stage: Other ML23027A2102023-01-27027 January 2023 GE-Hitachi Nuclear Energy Americas, LLC, Supplemental Information Supporting GE Nuclear Test Reactor License Renewal Audit – Audit Questions and Responses Project stage: Supplement ML23027A2092023-01-27027 January 2023 GE-Hitachi Nuclear Energy Americas, LLC, Supplemental Information Supporting GE Nuclear Test Reactor License Renewal Audit – Audit Questions and Responses Project stage: Request ML23054A3212023-02-23023 February 2023 GEH Supplemental Information for Ntr License Renewal Application Project stage: Supplement ML23067A4082023-03-0808 March 2023 Email from Anthony Chu, CA Radiation Safety 3.8.23 Re_ Draft NRC Environmental Assessment of the GEH Ntr Re_ State of California Review Project stage: Request ML23033A6712023-03-17017 March 2023 Federal Register Notice - GE-Hitachi Nuclear Energy Americas, LLC, Nuclear Test Reactor Project stage: Request ML23033A6702023-03-17017 March 2023 GEH EA and FONSI for License Renewal Project stage: Request ML23033A6722023-03-17017 March 2023 Ge-Hitachi Nuclear Energy Americas LLC - Environmental Assessment and Finding of No Significant Impact Regarding Renewal of Facility Operating License No. R-33 for the GE-Hitachi Nuclear Test Reactor Project stage: Other ML23086C0232023-03-24024 March 2023, 31 March 2023 GE Nuclear Test Reactor Safety Analysis Report and Technical Specifications Project stage: Request ML23086C0252023-03-24024 March 2023 Enclosure 1: NRC Ntr License Renewal Audit Questions Project stage: Other ML23086C0242023-03-24024 March 2023 GE-Hitachi Nuclear Energy Americas, LLC, Nuclear Test Reactor Safety Analysis Report and Technical Specifications Project stage: Request ML23086C0262023-03-31031 March 2023 Enclosure 2: Nedo 32765, Revision 6, Technical Specifications for the Nuclear Test Reactor Facility R-33 Project stage: Request ML23101A1852023-04-13013 April 2023 GE-Hitachi Nuclear Energy Americas, LLC - Report on the Regulatory Audits Regarding the Renewal of Facility Operating License No. R-33 Project stage: Other ML23128A3482023-06-29029 June 2023 GE-Hitachi Nuclear Energy Americas, LLC – Issuance of Renewed Facility Operating License No. R-33 for the Nuclear Test Reactor Project stage: Approval ML23128A3552023-06-29029 June 2023, 30 June 2023, 5 July 2023 GEH Ntr Lr Issuance Package Project stage: Request ML23128A3522023-07-0505 July 2023 FRN for Issuance of GEH Renewed Facility Operating License Project stage: Request 2022-05-26
[Table View] |
Text
February 8, 2022 Mr. Matthew Feyrer, Site Manager GE Hitachi Nuclear Energy Vallecitos Nuclear Center 6705 Vallecitos Road Sunol, CA 94586
SUBJECT:
GE-HITACHI NUCLEAR ENERGY AMERICAS LLC - APPROVAL OF THE REVISED OPERATOR REQUALIFICATION PROGRAM FOR THE NUCLEAR TEST REACTOR (EPID: L-2020-RNW-0038)
Dear Mr. Feyrer:
The U.S. Nuclear Regulatory Commission (NRC) staff completed its review of the updated GE Hitachi Nuclear Energy Americas LLC (GEH) Requalification Program for the General Electric Nuclear Test Reactor, dated December 3, 2021 (Agencywide Documents Access and Management System Accession No. ML21337A257), and finds the revised operator requalification program to be in accordance with the applicable regulations contained in Title 10 of the Code of Federal Regulations (10 CFR) Part 55, Operators Licenses, and consistent with the guidance contained in industry standard American National Standards Institute/American Nuclear Society-15.4-2016, Selection and Training of Personnel for Research Reactors.
During its review, the NRC staff noticed that the revised operator requalification program for the General Electric Nuclear Test Reactor (NTR) does not include the requirements associated with 10 CFR 55.59(c)(6), Alternative training programs. If GEH finds the need to implement an alternative training program for the NTR in the future, GEH should submit a revised operator requalification plan incorporating an alternative training program to the NRC for approval.
We request you implement your approved program immediately.
M. Feyrer If you have any questions, please contact me at (301) 415-5656, or by electronic mail at Paulette.Torres@nrc.gov.
Sincerely, Paulette Torres, Project Manager Non-Power Production and Utilization Facility Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Docket No.50-073 License No. R-33 cc: See next page Signed by Torres, Paulette on 02/08/22
GE-Hitachi Nuclear Energy Americas LLC Docket No.50-073 cc:
Jeffrey Smyly, Manager Regulatory Compliance GE Hitachi Nuclear Energy Vallecitos Nuclear Center 6705 Vallecitos Road Sunol, CA 94586 Thomas McConnell, Manager Nuclear Test Reactor GE Hitachi Nuclear Energy Vallecitos Nuclear Center 6705 Vallecitos Road Sunol, CA 94586 Scott Murray, Manager Facility Licensing GE Hitachi Nuclear Energy 3901 Castle Hayne Road Wilmington, NC 28401 David Heckman, Vallecitos Reg Affairs & Licensing Lead GE Hitachi Nuclear Energy Vallecitos Nuclear Center 6705 Vallecitos Road Sunol, CA 94586 Commissioner California Energy Commission 1516 Ninth Street, MS-34 Sacramento, CA 95814 California Department of Health ATTN: Chief Radiologic Health Branch P.O. Box 997414, MS 7610 Sacramento, CA 95899-7414 Test, Research and Training Reactor Newsletter Attention: Ms. Amber Johnson Dept of Materials Science and Engineering University of Maryland 4418 Stadium Drive College Park, MD 20742-2115
M. Feyrer
SUBJECT:
GE-HITACHI NUCLEAR ENERGY AMERICAS LLC - APPROVAL OF THE REVISED OPERATOR REQUALIFICATION PROGRAM FOR THE NUCLEAR TEST REACTOR (EPID: L-2020-RNW-0038) DATED: FEBRUARY 8, 2022 DISTRIBUTION:
PUBLIC JBorromeo, NRR NParker, NRR DHardesty, NRR LTran, NRR PTorres, NRR KRoche, NRR ADAMS Accession Number: ML22020A389 NRR-106 OFFICE NRR/DANU/UNPL/PM NRR/DANU/UNPL/LA NRR/DANU/UNPL/BC NRR/DANU/UNPL/PM NAME PTorres NParker JBorromeo PTorres DATE 1/21/2022 1/21/2022 2/8/2022 2/8/2022 OFFICIAL RECORD COPY