1 to Updated Final Safety Analysis Report, Chapter 10, Figure 10.3-3, Piping System Flow Diagram Main & Reheat Steam (Non-Nuclear)
ML21209A432
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 04/30/2021
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21209A581 List: ... further results
References
21-167
Download: ML21209A432 (1)


Text

14 13 I 12 I 11 I 10 i 9 I 8

7 6 5 4 3 2 1 1

I SYSTEM DATA '

~-:

A-2 1 -012 E-7

>-,' it! SET a 115 PSIG TO PC SET

~

a 105 PSIG LB/HR 1 64,800 PSIG 196

.F 523 REMARKS 100% LOAD FW

  • MS f;!l © T NOTE 7 3361 XPP-22A-FW =~~-,,

RNc2

-........,,,-r 6

~I ATMOS 151X 2058

, ~,0c L

  • r=--

S§_ ____ S

~

, - C14

' ~C RMa-148 IPY-2058-MS A 1 66,141 185 504 RUNOUT IEMERGI FEEDPUMP TURBINE SPEED CONTROL SIGNALS (WJ OWG 1080932 SH 17.22 GAI DWGS 1M§'-51-027, 017: 022 A

~

-__/YE\ __ jvr\_ __~ 8 12

..__-70 5 : - l ~ f - - - - - ~ ~ /

2821-MS 1"

_; " ~ - ~

':r' 3/4"' 7 C

ZS p /

RObll 2810-MS 2

RU,\JO J @owG 1080837 SH. 13 (GA! DWG IMS-41-011: 013)  ; FWP * ,.., .A , .J,. -4'~ .,) 2'1.. ,. > A A

~ ~

40,989 895 538 A$

(EMERGI G-4 NOTE, ~E i,\ ' ~F,C: 3/4" 3 22,400 100 335 REQ'O FE GA! GE M? :,

V 3361 L---.----~ NOTE 5 CTTI GE pGAI , ROb9 IPC-2058-HRZ-MS 2" 1

-121

, . - DRAIN 2134 ROo35

' 02\

~

Ycrz C-8 I

\ ROb9

!PC-2058-HRl-MS I 1452A-RS RC-9 1451A-RS ,;:>--*---1 '

I

/4,*

RC-9 <.

"----~

-051 }- ---'31---

4*~

~

j - 151X('~i-,--..902X 2"

8" AS 3 1)

RObl

'L-----

YE 2805A-MS 2817-MS ...i.

2

.. ,. 6"

'\: 7 ...:;..J IFT-2134-LR-RS FEEDWATER 3365 ROo5 / 0 3/41* ~~:,.

\'----.-iR-ieO~o:"55iSc_

' ,. 2816A-HS RDbl RObl 1453A-RS PUMP TURBINE RObl B J.-- -==~~=IFT-2134-HR-RS !PT-2l38-HR RS\ / IPI-2136:-HR-RS "A'

  • RC-9 3/4" '---., RO69 B 8

S /

, ,. !PX-2046 HRl-MS TPP-22A-FW 1 ,. '---., R0b9 PT PI I I ..,IP'-'x~2"'0-:C4sC-:_:UHR"'2=Ms 0 2138 2136 I.____. YE 3364 --@--.lD NOTE 7 PX 2046

'v GE MECH-HYDRAULIC ----------------------:


-----~-----(2\

SE SE SE TURBINE SPEED .'~

13239 13240 13241 CONTROL SYSTEM --- . A-7 C

GE DWG 509E550 FA GAi DWG IMS-17-042

L_______________ ~------1 -081 >

______________ f~-------- ----~

0-9 (6 PLACES),.-_ _\_ _ _~\_ _ _ _ \_-, C

,'__ FW PUMP 'A' .@YM E] 1F::21------ FW PP A cs


, LYDT I BOX r-- 01697 NOTE 6

ZS c12 8"

SEC XPN6036 FD E-9 D-2

' , * ... l" -123 _,,>

. - "' ... 301X -0a1 1

~

\ START-UP DRAIN FW 0 RNo-33 ' NOTE 3 1465-RS 1464-RS

~---~ 0 X

oi '

FE GA! GE 2144 ROa35 RC-9

/14528-RS RC-9 1451B-RS E l----,-M"'S-----,---,,,22;::-;8,;--;3;::2;----,,-2;;-;2:;-;8;::3:;;3-7 A 8" Q / 2805B-MS- 'L._

YE *~ 6" 6" E

,---.. RDbl V' 4" --- 2 RS 1451 1465 ' , 7 ~ -J lFT-2144-LR-RS 3367 HP FEEDWATER MS 2801 2899 3/4 ~~.:. RObl RObl RObl PUMP TURBINE SYSTEM SUFFIX FIRST NO. LAST NO. ,.....-..._ IFT-2144-HR-RS "B'

!PT:2148-HR-RS \ /lPI-2146-HR-AS RC-9 VALVE NUMBERING FT 2144 w

I N

N

"- - ~

z

~

7

  • 7 TPP-228-FW

' 0

' * '---., R069

' PT PI I I 1PX-2056-HR2-MS 0 2148 2146 2" PX 2056 F '

0 SE 13242 SE 13243 SE 13244 GE MECH-HYDRAULIC TURBINE SPEED CONTROL SYSTEM F

8" GE DWG 509E550 FA i'  :'_______ , -081 > F-9 (6 PLACES) ~ - -__\_ _ _

1__

~t____l_-, GAi OWG IMS-17-042 L---------------------------~~-----------~ H-3 FW

-352 IF=~7 I ------ FW PPB DCS MD C12 XPN6037 G

G

~

F-9 6"

\ -a12 M.S.

R069 NOTES:

l. DOUBLE ROOT VALVES SHALL BE VENT [ .. . 7 22632=~

p ....

USED ON MAIN STEAM SYSTEM.

2. NO BACKL'\G '1INGS SHALL be_ R069 /

22833-MS H USED 0\ STEAM PIPII\G. FE GAi GE

3. c_OW DEAERATOR LEVEL TRIP. 2154 H
4. INTMJ. BLDG. SU'-IP T~IP. ROa35 RC-9
5. TRIP /?EGET fCOR STOP VALVES.
6. PILCT VALVE ASSEMBLY.
7. LOCATED IN ENCLOSURE MOUNTED L----~-~=--~-==----'""'.:r:------t>~A/_1__!_45_2_C_-R_s"1_ __.;:30:;;t;,x_ _ _ _ _ _ _ _ _ _ _s_,,_ _ _ _Q,....,\___"c-l,.' ;,-;::.-1-'"-";;.q'rl__1*_s_,c_-_R_s_ _ _7 6"

...L V ~ ' \\ - L. P. YE ON PL:MP S<!D: ' 7

_RO~l-~==

, {IFT-2l54-LR-RS V 3/4" ROc55 3369 FEEOWATER TPP22A XPN5305 3/4!,,:. ~,:. RObl 1453C-RS PUMP TURBII\E TPP228 - XPN5306 i.--::-,; !FT-2154:He'ss RObl RObl "C'

- IPT-2158-HR-:RS \ / IPI-il5S-HR-RS TPP22C - XPN5307 TW 1" FT

' 7 ' 7 RC-9 * "" R0b9 l

2166 2154 N N z

~ ' .,. TPP-ZZC-FW

,/ IPX-20BB-HR2-MS 0------ J_ ~ c2

© J 'I

  • TW 1" ' 0 2164 l - - - - 1 ' <J:!(3 PLACE'"Sl 0 Pl I

~-@/ __ jYT\_ __ ~ ~ J 2156 301X B-4 GE OWG 1348550FA

~~ r 2;~G i "' 'iS LL N

  • B

<I

-012 GAI DWG IMS-17-036-2

-=--,-,=:c-,-c,,= -:-,,~,:---, NOTE 7  : r;'I __________________________ J I FSAR FIGURE 10.3-3 1""

M.S. SE SE SE r GE MECH-HYDRAULIC ------------- -------'----V  : --------------

13245 13246 13247 TURBINE SPEED -  :  :

CONTROL SYSTEM SOUTH CAROL[NA ELECTR[C &GAS COMPANY

~

--,

  • A-7 ,

I I ~  !

DRAWING LEGIBILITY GE DWG 509E550 FA ' H-9 i \

1- - ~ ,

(6 PLACES! ,

i

~------~---~-,

GA] DWG lMS-17-042 L___________________ FW________ f:\--------< -081 I CLASS 1 VIRGIL C. SUMMER NUCLEAR STATlON

--c--:-::-:-,-;-----j SCE&G CAD ENHANCED PIPING SYSTEM FLOW DIAGRAM HYDROSTATIC TEST TEMP - G0'F l--*

FW pp C cs PUMP 'C' _ --_@VM \ FW MAIN & REHEAT STEAM CNON-NUCLEARl I l------


LVDT ' 01699 t 3 100 390 115 375 < 1% 150 EJA INI BOX i K F::0 XPN6038 NOTE 6


[SCY\ ______________ _____________________________________ J 1 12 3124103 JTS R[VIS[D PER ECR 50239 MGR DDJ 6 DESIGN ENGINEERING 2 270 600° GE c12 1-_!1'!_,-J-.-5ec*';c3*c:'2+R'c-H"'M"-f-~R~c=;V";;l;:S"'E;;D_f-';;'.l=;H:;--;E_';;C;;'R'-:-:;t,~0:';:0:;:9::;1_ 7 ~o;::;DMJl-:G;;;,Ji,Rv"7 ,~.,

K L---,-------.--~ \~

1 '.185 600' 1284 5021' < 11/. 1780 EJA 10 9112101 RHM REVls::o PER MRF -22553 R~"

11~'. JMW ,-scN.AcOMPNfi' MAE V. C, SUMMER NUCU',AR S'ATiON JE:NK'NSVILL'::, S. C.

CHECKED LE APPRCVAL

' g 7115127 RHM REV!SED PE~ CGSS-97-0381 LEK MGR 1.

' 1----e--µ=~~ ---='~~~~"';  ;;::;;;-;;'~~.; ;::-t7i7.:,7 RCS 2

PJM 3.

PJS DcSIGN DATA N HYO BY CHK RC:MARKS

@ C TPP22C 8

7 5112/96 DDJ 5/Q/52 RCS BY REVISED PER MRF -90102 R~VISED PER CGSG-10059 REVISION JMC PJM GVM PJS LE NO. DATE CKD. BY APPROVAL 5' )0' 221*