ML22194A445

From kanterella
Jump to navigation Jump to search
2 to Updated Final Safety Analysis Report, Figure 9.3-14, Rev. 32, Piping System Flow Diagram Non-Nuclear Plant Drains
ML22194A445
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 06/27/2022
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22194A236 List: ... further results
References
22-179
Download: ML22194A445 (1)


Text

14 13 12 11 10 9 8 7 6 5 4 3 2 I SYSTEM DATA GPM FT "F BY REMARKS 50 70 120 JJW 2 50 70 120 JJW 3 75 70 150 JJW A A 4 50 30 150 JJW 5 500 100 120 SCE&G 6 1500 100 120 JJW 153X 7 75 70 150 JJW ROa-38 2" 3" 2" 3" 8 75 70 150 JJW / 2421-MD 9 250 80 150 JJW Hl HI 2" 2" 2" 2" 10 25 50 100 JJW ROo-22 ~--7 ROo-22 ROo-22 ~--7 ROo-22 ROc-23 11 20 50 100 JJW / 2420-MD N356906 2402A-MD \ / 2402B-MD 2404A-M \ LS / 2404B-MD 12 20 50 100 JJW 2449A-MD"'

13 25 50 100 JJW 7 7873 ROc-68 ROc-68 ROc-68 14 30 30 100 JJW 2401A-MD \ / 240IB-MD 2403A-M "-:

I u~

I. ROc-68

,----------.._ F N356906 15 40 50 100 JJW wl~<I:

/ 2403B-MD 2

2448-MD -..._

B 16 30 30 100 JJW IF) B SCE&G EL. 412'-0"

~

ROb-33 /

2" 2 c~ ' 7884 PI

.--~ 2" !PI- 7852-HR-MD LG 7810 ROb-1 IPl-7882-HR-MD 50 GPM MF-2F

/ 2 HP 3600 RPM c-,-- 50 / ROb-1 GPM IPI-7884-HR-MD

/ 2 HP 50 GPM IPI-7874-HR-MD 2 HP 3450 RPM 20 GPM"\

460 V MF-II ROb-1

!Pl - 7862-HR-MO 20 HP 500 GPM /1500 GPM 60 HP

c=~M~F~-2~F~ 3600 RPM '~=-M~F-=2~G~ 1800 RPM N357069 MF-2E 1800 RPM XPP-99A-MD 460 V XPP-99B-MD 3" XPP-98A-MD 460 V XPP-98B-MD XPP-136-MD 460 V XPP-105A-MD XPP-105B-MD 460 V SCE&G XTK166 3" ~ CONDENSATE PUMP PIT SUMP =A=U=X=.--=C=O=N=D=E=N=S=E=R'----C=L=E=A=N=I=N=G=----=P=IT=------=S=U=M=P ~ INTER. BLDG. SUMP D MAIN CONDENSER CLEANING 10" SCE&G RWST PIT / IFT-7897-HR-MD 3" 153X (b'-0" x 5'-0" x 5'-9" Dl DRAIN TANK 2"

(4'-0" X 4'-0" X 6'-0" 0) MRF -22177 /

2440-MD Le-a BATTERY ROOM (9'-0" X 4'-0" X 5'-9" 0)

~ (3'-0" J'-0" 3'-0")

C (FE\

-@ C X X XPS-148-MD 2" MRF-22177 F SCE&G 2" SCE&G 2443-MD ,, XPS-15~7 ,, ROa-38 ~-

2445-MD°'°' 59714

/ 2444-MD ~ -1_5_3_X_ _ _ _ _------< 2" SCE&G 3" 2" 2 2 2426-MD \ 21/2" 21/2" 153X ROa-38 N356274 N359044 1/2446-MD 153X D-911-102 2" 13-7--------i f--------,-7)'~1-----I ' - - - - - - ~ / 2424B-MD

\ SCE&G 244 7-MD ROo-38 2428A-MD \

-,-0 153X HI

/

ROa-38 2428B-MD 2"\ SCE&G I

2" LDC B-10 ROc-23 2425-MD ROb-33 3" 153X 3" 2" ROc-23 Ol----

3/4"

\ SCE&G IFT-7897-LR-MD TANK 2438-MD 2" 153X ~'° 2" 153X AREA I 2437-MD C'l r--. co SCE&G Fl /IPI-7842-HR-MD / 2423B-MD U)

DRAIN ROc-23 2" ROc-23 2427A-MD \ I / 2427B-MD N c, '

2439-MD ~':T 3/4'~ <I:

U)'  !PCS

!al, o u

_!____~

~ ~

a, I

w _J t

~

2" Fl 2"x3/4" EL. 436'-0" I E9 D 3" 153X 3/4" --+~_J D 3/4" 3/4" 2 HP .-~20 GPM 3450 RPM 2 HP '-~25 GPM '-~25 GPM A H l r -ECR50910

==~~

TO YARD /ROb-33 400 V 3450 RPM / RH-4 MF-lH / 2 HP U) 79653-RM

/ MF-lH DRAIN IP!- 7892-HR-MD BY SCE&G 25 GPM 25 GPM BY SCE&G 460 V XPP-131-MD XPP-129A-MD 3450 RPM 460 V XPP-129B-MD

' U)

G XPP-100A-MD XPP-100B-MD CHEMICAL FEED EQUIP. DRAIN SUMP-(IB) BY SCE&G 2419-MD CAUSTIC TANK AREA SUMP-OUTDOORS ECR50910

<I: "'

a, 155X 151X 2"

REFUELING WATER STORAGE TANK AREA SUMP 118" DIA. x 16") 79652-RM (4'-0" X J'-0" X J'-0" D) c-8 T2"

-734 '------;c;;-:-;:;::;------j~t-7 BY SCE&G 2435A-MD'-

BY SCE&G

/ 2435B-MD (J'-0" X J'-0" X J'-0")

ECR50910 XST-178 151X wx ' 2" 155X ---,--x--.- BY SCE & G E TENDON 6" 2" LO 3/4" X 1/2" 3/4" X I/,,

12 6"

2436-MD E

GALLERY DRAINS SCE&G 151X 156X ROo-28 w

3" 2449B-MD / 2422-MD 3" 3"

~--@' 3/~ MRF-22177 HI 6"

,/ A-9 6" I 4 " "\

_)-----M-cH-:-cl-(j, ROa-4 2418B-MD A-9 e ROo-22 2" 59847-RM 2" X 4"

,-- 156X 10 X

ROo-22 2" ~--1 2" ROo-22 ROa-4 2418A-MD '- LI 806-006) rv ~ ~ 006-006 > 2430A-MD \

~- ROa-22 - -TURBINE]

BLDG I (0

Lf1 2410A-MD \

7 LS 7823

/2410B-MD I fLs\ I N

r--.

"' a:

NOTE 4 RDc-68 2429A-MD \ '

LS / 2430B-MD 1 ROc-11 ROc-11 R c-68 2417A-MD I ~l I 2417B-MD PI C)

N <I:

' \ 2" 7875 7 2" ROc-68 I NDERGRDUNDI ROa-22  :": ROa-22 ROc-68 "'I . I .

i5I>--" 7814 "'I .

1 2429B-MD I

~s~

2432B-MD 2409A-M ,

u~ /2409B-MD s u~

WI~

WI_J

,: <I:

R b-1 3" l~ ~I~ ---~

,: <I:

3/4" PI I I F ~8 ~-----~-H[ ___ 2_"-~--------, 2" r--ci_ L ~ ---~ 2"

\IPl-7824-HR-MD 4"x3'~

7878 4" I I F ROc-68 \ _ ROc-68 EL. 388'-0" r+--+--+c=i=- EL. 411'-9" --JC--./EL. 436'-0" ROb-1 I I 2431A-MD LS l LS 2431B-MD \

" 11/2 HP 3" IPI-7876-HR-MD ROb-1 3600 RPM 2" ROb-1 3" \ ROb-1 I COLLECTING I 2" 7835 7837 ROb-1

/Rb-1 460 V i--~ 3/4" IPI-7812-HR-MD IPI-7814-HR-MD IPI-7878-HR-MD I SUMP I IPI-7838-HR-MD IPl-7822-HR-M/D I NORTH OF ) I ii>"

WI_J ~s 50 GPM 50 GP~ MF- 2 C / 250 GPM 10 HP 250 GPM\ MF- 2 C 30 GPM\ 1 HP t30 GPM

( SUBSTATION FENCE L _______ _'J

,: <I: MF-2B MF-2B 1800 RPM MF-2M 1800 RPM MF-2M

-~~ -- 'ccx"'p""p---,_5cc0ccA=--;--;M""°D XPP-104A-MD XPP-104B-MD XPP-60B-MD 460 V XPP-144A-MD 460 V XPP-144B-MD EL. 399'-10" D

,: 2" 2" ACCESS GALLERY SUMP 6" TURBINE ROOM SUMP CIRCULATING WTR PMP HOUSE SMP ECR-72280
r:'

(6'-0 X 3'-0" X J'-6 0) 3"

"' (9'-0" 4'-0" 5'-9" 82500-MD

.D Dr--.

ro 40 GPM 40 GPM 4"

4" X X 0) 3" NOTES (J'-0" X 4'-0" X J'-6" D)

G 0: C-a 2 HP ~--~----17----------------Eli---------------<7 1. ALL PIPING TO BE LINE SPEC 151X EXCEPT AS NOTED ECR-72280 G CL MF-21 )

1800 RPM MF-210) 82501-MD XPP-146A-MD XPP-146B-MD 2. IF) INDICATES SUPPLIED WITH PUMP 460 V ...---THREADED 3" 3. TOTAL COMBINED FLOW IS 2000 GPM WITH XPP105A & B RUNNING PIPE CAP DIESEL GENERATOR BLDG SUMP 2" 2" 2" 2" 4. TYGON TUBING - NOT PART OF LINE SPEC. 151X A-5 (2 PLCSI (J'-0" X 4'-0" X 3'-0" 0)

ROa-22 2412A-MD'-

HI HI ROa-22

/2412B-MD ROa-22 2414A-MD'-

HI HI HI HI


@> I ROa-22 2414B-MD ROa-22 2416A-M '-

HI HI ROa-22

/ 2416B-MD G-2 il:-DSE_ *I -081 1 VALVES *

< TRIP FW I FW

~ ~

ROc-68 ROc-68 ROc-68 ROc-68 ROc-68 ROc-68 -014 I-PUMPS-I 2411A-MD \_ / 2411B-MD 2413A-MD\_ / 2413B-MD 2415A-MD\ / 2415B-MD MS ROb-1 ROb-1 R b-1 ROb-1 IP!- 7807-HR-M \ LS MECH. / IPI-7808-HR-MD / IP!- 7805-HR-MO / !PI- 7802-HR-MO I

7809 ALT. I PI PI PI L_J'-'L__J PI PI f-------1 3/4,, PI 2/3 HI-HI SUMP

_J TO SW PUMP 2" 7807f------J)l'.f----l f--,::-::f-----1 7808 7804 7805 7801 ROb- '\ f--1::-::f------, 7802 LEVEL CLOSE H HOUSE INTAKE 3/4" 3/4" 3/4" 3/4" FEEDWATER VALVES H

EL. 411'-9" EL. 411'-9" !PI- 7801-HR-MD EL. 411'-9" ROa-22 STRUCTURE CHANNEL "B" 2434A-MD ROb-1 2" !PI- 7804-HR-MD 2" 2" 2" 2" 2"

ROa-22 75 GPM 75 GPM

~I v- / 2434B-MD 75 GPM /

MF-2J XPP-103A-MD 3 HP 3600 RPM 460 V

\ MF-2J XPP-103B-MD 75 GPM /

MF-21 XPP-102A-MD 3 HP 3600 RPM 460 V

\ MF-21 XPP-102B-MD 75 GPM /

MF-2H XPP-101A-MD 3 HP 3600 RPM 460 V

\

75 GPM MF-2H XPP-10IB-MD

~- -

2/3 HI-HI SUMP LEVEL CLOSE FEEDWATER VALVES

~- ,-1 VCALLOVSEES C-14

-I -081 >

LS ROc-68 ----------~ FW 7865 7 2433B-MD \ 2 ,, ROb-l SUMP C SUMP "B" SUMP "A 11 CHANNEL "A" B-7 I

2" Fl /~I~P~l-~7~8~6~8~-H~R~-7M~D (5'-0" x 3'-0" x b'-0" 0) (5'-0" X 3'-0" X 5'-0" 0)

(5'-0" 3'-0" 5'-0" DJ

~ - - - 1-0s3

- - ~ 3/4" X X I FW

-7 J EL. 425'-0" I

,---1-083 > ESSENTIAL J

,: 2" INTERMEDIATE BLDG.SUMP PUMPS I G-7 FW 0:
r:

(0 L---1-003 > FSAR FIGURE 9.3-14 (D FW

- co 30 GPM\ 1 HP / 30 GPM

' r--. MF- 1800 RPM MF-

.D '

o - XPP-14 7A-MD 460 V XPP-147B-MD SOUTH CAROLINA ELECTRIC~ GAS COMPANY 0: 9c, SERVICE WATER PUMP HOUSE SUMP DRAWING CLASS LEGIBILITY 1 VIRGIL C. SUMMER NUCLEAR STATION (3'-0" X 4'-0" X 3'-0" 0) PIPING SYSTEM FLOW DIAGRAM NON-NUCLEAR PLANT DRAINS HYDROSTATIC TEST TEMP - 60° 29 0J/09/2016 JMR REVISED PER ECR-72140 RHM DB K Q DESIGN ENGINEERING K r 2=8 +0= 09~12~01~0 l-'J~T~S-+-R=E~V~IS=E=~P=ER~E~C~R--_

2'~ 7= 12=5=0---t-=M=GR'-'--,~RDH= 0 MJ~ A s~E~~P.-INY V. C. SUMMER NUCLEAR STATION JENKINSVILLE s. C.

27 09/21/2003 JTS CAOO ENHANCED PER ECR-50239 DDJ MADE CHECKED LE APPROVAL ALL 75 150 JJW ENTIRE 32 06/01/2019 CMS REVISED PER ECR-72280 chk TCL 1. 2. 3.

r---+----+---+-------------+-------1---

Iii) PSIG. F PSIG. F DURATION HY- BY Y T M 31 04/19/2018 JMR REVISED PER ECR-50910 AME T JB SRF RHM DDS CHK'D REMARKS 30 11/11/2017 JMR REVISED PER ECR-71635 RHM AL u 1 NORMAL UPSET ORO LE NO SCALE D-302-352 32 DESIGN DATA NO. DATE BY REVISION CKD. BY APPROVAL DRAWING NUMBER SHT. NUMBER REV 5' 10' 15' 20'