ML22194A399

From kanterella
Jump to navigation Jump to search
2 to Updated Final Safety Analysis Report, Figure 9.4-35, Rev. 1, Sheet 2, Building Services Flow System Diagram Eb HVAC DG1 Room
ML22194A399
Person / Time
Site: Summer 
Issue date: 06/27/2022
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22194A236 List: ... further results
References
22-179
Download: ML22194A399 (1)


Text

14 I

13 SYSTEM OPERATING DATA NOTE 10

(>

AIR FLOW AIR TEMP.

CFM

  • F A

3

'l""

l'l-120 4 ( 1.

'l5-200 5

(' 3 1'V120 6

14 0 1'l/'l5 B

C D

E r

G H

J K

SYSTEM DESIGN DATA NOTE 10 IT)

AREA AJA FLO AREA AIR TE AREA EMERGENCY*

r" W CFM MP.* F AIR TEMP. *F 3

'l00/21,'l00 1"!/120 l"l/120 L

I 12 I

11 I

10 I

9 EB DIESEL GENERATOR ROOM EL. 436'-6' I

a 7

I 6

r------7------------------------,---------------------------

I 1

$ FIRE SERVICE FAN AND DAMPER NOTE 4 l

I I

FS DISABLE I

I 2 HP DIESEL I

I RPM 1160 L--------fssl P5387 GENERATOR I

I 460V I

~

AH421D XEG0103 I

I L---~~--'

DIESEL I

GENERATOR

[

I 5

I 4

FAN A.

B.

I 3

I 2

I OPERATION NOTES:

VENTILATION FANS XFN0200 ANO XFN0202 OPERATE AT ALL TIMES.IF A LOSS OF FLOW IS DETECTED AN ALARM IS GENERATED AND ADDITIONAL FANS ARE STARTED AUTOMATICALLY.

XFN0204 STARTS AUTOMATICALLY WHEN XEG0103 rs STARTED.XFN0203 AND XFN0205 WILL START AUTOMATICALLY IF DG ROOM TEMPERATURE INCREASES 1

ABOVE 80 DEG F ANO OG IS RUNNING.XFN0203 AND XFN0205 WILL SECURE IF ROOM TEMPERATURE DROPS BELOW 60 DEG F.

C.

HVAC ALARMS ARE INDICATED ON XPN5387.GENERAL 'EB HVAC TROUBLE ALARM" IS INDICATED ON TEMP MONITORING SYSTEM AND ANNUNCIATED IN MAIN CONTROL ROOM.

0.

COMMON LOW DG COOLING FLOW ALARM LIGHT ON XPN5387.

OUTSIDE AIR INTAKE

[~

.._.u.----,

XEG0103 FC RUNNING

-f71-H~4*~---->

FC i----+------i/ t----,--+-:)

XOP5201-AH $w

-j 6.

--- 14000 CFM SIGNAL

'"'\

~

i 1----+--:._;

XDP5200-AH

---9 1100% RADIATOR COOLING EXHAUST)

CFM SUPPLY)

~

DIESEL DRIVEN Q-_

FAN RUNNIN~

r----

L (1001/. RADIATOR COOLING

\ t=TR50793C NOTE B XFN0204-AH

~

~~~1~1f FAN r


XEX0103-SSW-1-AH r- - - - 7 r::::::7 P5387 NOTE B I

I k----~AH421E L

LOW FLOW~

~

I

~s I FIRE SERVICE FAN AND DAMPER

- - 1 NOTE 11 ~

_ DISABLi_ __ _tlOTE4 _______

1 _______ 1 I ~~fR~L~~~

I I

I I

INOTED--v I

1 1

I

!FAN RUNNIN~L I

3/4 HP 1.5 HP I

L----

1 RPM 860 I

RPM 1725 I

I 460V I

460V I

I ab l

LOW FLOW-~

i XFN0204-SSW-1-AH 1 NOTES8°J1~

I I LOW FLOW I

ALARM LIGHT~

I iNOTE_D_-V I


*-__J NOTE 8 OUTSIDE AIR INTAKE

[,

I

,--,~-~--

FC FC

'"'\

-j 5 >- -- 7000 i

/t-----H: 5 >-

t--+-----1 / 1--~-+----:._;

CFM I

t--.----+-:)

--* ~CFM (1001/. ROOM COOLING EXHAUST)

XDP5202-AH +w

<1001/. ROOM COOLING SUPPLY)

II XFN0203-SSW-1-AH $w XDP5203-AH r

FAN ~UNNIN~-

L e

\

I ECR50793C I

I I

Xt-N0205-AH NOTE B I

I L LOW FLOW~

I XFN0205-SSW-1-AH I

rFAN~UNNIN~ NOTE 8 II ECR50793C XFN0203-AH NOTE B iNOTESB,11~

I I

~

I LOW FLOW L

I I

I

-0.

I rr;J P5387 t_;::'.JAH421C I ALAR~ LIGH~L k LOW FLOW I

r I

I INOTESB.11 A

I I

NOTE D I

I LOW FLOW L

I I

I I

IALARM UGH~

I I

rNOTE~--~

I r;;';;i FIRE SERVICE FAN

~

DISABLE NOTE4 OUTSIDE AIR INTAKE

[QJFC

>--+-----</

. 3>

XDP5207-AH

-- 900 C1001/. VENT AIRl CFM I

I.

I FAN IN OPER. 116 HP I

L ----- RPM 1697 (VARIABLE I

SPEED I

tz0v FANMOTORJ I

I I

H3.

i XFN0202-SSW-1-AH SW I

1---$-.--1/1--FC-~

I

\_f.

..,cm~,.9.

-3.1

,: r:_

I I XDP5206-AH XFN0202-AH NOTE A I

I I

i I

I I

I I

I L...---------------i I LOW FLOW I NOTE11-A NOTE 8 L

I LOW FLOW r ALAR~ LIGHT L

I LFA"!_f<UN_l:!!!'l~

---900 CFM (100% VENT AIR)

ALL SYSTEM COMPONENTS ARE NON-NUCLEAR SAFETY REI ATEQ ORAll!NG CLASS LEGIBIUlY 1 GENERAL NOTES (1-11):

SEE SHEET 1 FSAR Figure 9.4-35 SH. 2 SOUIII CAROUIIA ELECTRIC & GAS COMPANY WIQI. C. SUMMER NUCLEAR SIAQ BUILDING SERVICE SYSTEM F'LOW DIAGRAM EB HVAC OGI ROOM DESIGN ENGIWEERING

  • EMERGENCY CONDITION EXISTS WHEN NORMAL POWER IS LOST AND DG IS PROVIDING POWER
v. C. ~

NUa.tAR STATION ~

5. C.

I I I 5'

I I I I 101 t

1 4/28/15.ITS Pl'R c-r-R.

0 2/3/15 IMC

  • ~~"en pc-D FrR-tst>7q'l

"°-

DAT!

BY REVISION

ti

~

DC, ur 0 DC LE Cl<O. 8Y -...

IIAD£ Ott:0<£0 u:-...

~

JMR MGR RS 0-912-192 2

1 Std.___.....

7 A

B C

D E

r G

H J

K