2 to Updated Final Safety Analysis Report, Figure 10.2-3A, Control Diagram Turbine Stop Valve
ML22194A397
Person / Time
Site: Summer 
Issue date: 06/27/2022
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22194A236 List: ... further results
References
22-179
Download: ML22194A397 (1)


Text

CVl*l Tl CV3*LTI XVG-2822D-MS CONTROL VALVE

{CV-I )

XVG*2822A-MS CONTROL VALVE

( CV-3 )

[)ISi< DUMP VALVE 0

STEAM FROM MAIN STOP VALVES BEFORE SEAT DRAIN*

____ REFER TO MOISTURE REMOVAL AN[)

EXTRACTION DIAGRAM XVX*22822D CVl*FA SOLENOIO-OPERATEO,--

FAST

  • ACTING VALVE XVM*2282lilll CVl*SVJ SHUT-OFF VALVE*SET TO OPEN AT 500 P.S.l,G.

XVM-228210 I

I DISK DUMP VALVE 0

STEAM FROM MAIN STOP VALVES BEFORE SEAT DRAIN*

REFER TO MOISTURE REMOVAL ANO XVX*22822A CYJ*FA EXTRACTION DIAGRAM J COIL

.,..._SERVO VALVE IPS-5843 IPS*5843*Hl* TB SOLENOID-OPERATE0,---1..r FAST-ACTING VALVE

!PS*5843*HR* TB XVM*22820A CVJ*SVI XV *22821A SHUT-OFF' VALVE-SET TO OPEN AT 500 P.S.l.G.

5' 10' 15' 20' y.

J COIL SERVO

.,..._1/ALIIE CV2*LTI V

  • CV4*L Tl XVG-2822C-MS CONTROL VALVE

( CV-2)

~

I OISI< DUMP VALVE 0

STEAM FROM MAIN STOP VALVES BEFORE SEAT DRAIN -

REFER TO MOISTURE


REMOVAL ANO EXTRACTION DIAGRAM XVX*22822C CY2*FA

$$$$$DGNSPEC$$$$$$$$$$$$$$$$$$$$$$$$$$$$

$$USERNAME$$ $$$$$SYTJME$$$$$$

CRACKING POINT <CP>

Viii. VE NO, E,"'

E,..,

SL..,

!VOLTS>

(VOLTS)

HNCHESI I

0.000 5.000 0.0aq 2

0.000 5.000 0.089 3

0,00f/J 5.000 0.089 4

3,890 5,000 0.089 E,.,.,

!VOLTS) 3.890 3.890 3.890 CONTROL VALVE DATA TABLE SEQUENTIAL OPENING INTERCEPT POINT UPI E, 111'1 SL.,,

(VOLTS)

UNCHESI 2.527 2.315 WHEN *4 IS UP 0.009 2.559 2.286 WHEN *4 IS UP 0,089 2.572 2.275 WHEN *4 IS UP 0,089 FULL ARC OPERATOR Ee = INPUT TO DIODE FUNCTION GENERATOR BOARD E, = POSITION FEEDBACK TO PRE -AMPLIFIER BOARD CSEE SCHEMATIC DRAWING - VALVE POSITION UNIT)

SL = STEM LIFT FOR VALVE CURVE ADJUSTMENTS,SEE FIELD LINE INSTRUCTIONS.

!PS-5841 OPEN !OEl Viii.VE E,..,

E"'"'

SL.,.,

DIA.

IINCHESI

!VOLTS)

(VOLTS)

!INCHESl 4.344 0.000 4,50q 18 4.345 0.000 4.589 18 4.345 0.000 4,589

!B 5.000 0.000 4.589 18 1 s.000 0.000 1

18

!PS*584l *HI* TB SOLENOIO-OPERATED,-----illol FAST-ACTING VALVE SHUT*OFF VALVE*SET TO OPEN AT 500 P,S,l,G.

~

IPS*584l*HR* TB XVM*22820C CV2*SVI J COIL 14-_SERVO 1/ALIIE LEGEND OIL OR HYDRAULIC FLUID LINE ---

ELECTRICAL CONNECTION XVM*22821C WATER LINE -**-**-**-**-**-**-**-**-**-**-**

COMPONENTS SHOWN IN PHANTOM -

XVG-2822B-MS CONTROL VALVE

( CV-4 )

OISI< DUMP VALVE 0

0 STEAM FROM MAIN STOP VALVES BEFORE SEAT ORAIN.

__,, REFER TO MOISTURE REMOVAL ANO EXTRACTION DIAGRAM XVX-22822B CV4*FA

!PS*5842 IPS*5842*Hl* TB SOLENOIO-OPERATEO,--

FAST-ACTING IIALVE SHUT-OFF VALVE*SET TO OPEN AT 500 P.S.I.G.

IPS-5842-HR* TB XVM-228208 CY*SVI V.

3 COIL

.,..__SERVO VALVE 5

qn111 RHM 4

5/12/U OOJ 3

{/18/118 JMR 2

l/5tal RHM 1

3/31!/'II! DOJ 6

2/25115 JMR NO.

DATE BY BY PURCHASER 1600 P.S.!.G. HYDRAULIC FLUID TO OPERATING DEVICES

.0 - 5 P.S.I.G. HYDRAULIC FLUID DRAIN 1600 P.S.I.G. HYDRAULIC FLUID TRIP SYSTEM 1600 P.S.I.G. HYDRAULIC FLUID TO JET FEEDBACK SIGNAL TO ELECTRO-HYDRAULIC CONTROL CABINET DRAWING LEGIBILITY CLASS I SCE&G CAO ENHANCED REVISED PER ECR-50592 MGR GM REV PER ECR50592B & ECR50592V MGR AME REVISED PER MRF-22553 MGR JMW FSAR Figure 10.2-30 ONTROL DIAGRAM 251R45P2o DESIGN ENGINEERING NUCLEAR STATI CHECKED JENKINSVILL S. C.

L APPROVAL REVISED PER CGSS-00-0005 MGR REVISED PER CGSS-97-0662 MGR JEG LEK

  • A. V.N.

M.G.R.

J.M.W.

6 REVISED PER £CR* 72033 R/111 12*81:l MGR REVISION T~

lMS-27-248 CKO,BY APPROVAL