ML21209A149

From kanterella
Jump to navigation Jump to search
1 to Updated Final Safety Analysis Report, Chapter 7, Figure 7.2-1 Sheet 15, Functional Diagrams Turbine Tip Runback and Other Signals
ML21209A149
Person / Time
Site: Summer 
Issue date: 04/30/2021
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21209A581 List: ... further results
References
21-167
Download: ML21209A149 (1)


Text

.. TU,M C.'-W*

)IMII U'<(\\. OR 'l,'t "n\\A.Ni..l,_... llf.'1.Tr.,}

,._ 4 TUABINI. POWER

  • ~

TIii!"

(TV_RB'li.lE. IMPULSE CIIAMElt:R [!IP.!>TSTAGl[JPI\\E"6\\ll\\f..)

'TAAII0,(;'-1.1.TZ).,------....;'-------"--------------..:....

t.*H 0.C.POWE.R FAILURE.--+-------~

CO,.OEI\\ISEfl VACC\\IUM 7_-.!:f:"-------,

(TYPICAl.)

TURIOINE. BFIG. OIL "l_--9"------,

TUR&INE. PROTECT10,r TRIPS OVl:RSPEEO (AS RE9UIREO 8Y OTHERS)

OTHER StG-NALS ENe: GIZE MASTEFi' 15Y BY 11EC11ANIC.AL m1P SOLENOID

. S=*C CTl<tl.P.> @ 11.E."'-..

l)VMP

,-0-UM....

P ______

_!:::::::=,=-'

t4.\\ElM 'f\\e:.P.J..'TtOt,J OP..

THRUST e,e"'-R.1'4C:t w£'>,.ft oq l.Ofl -G Cll. t>flE~'i,1:P.t CP.

L0'/1 V"-CUIIM TIIRBIKE TRIP.

(av CTIIERS)

"TO 6ENEFl,'\\'TOFI

'TRIP EME.RGE.,.CT T~IP I HOTREO\\INDANT


,----T----7 I..

I BYL

~-~

- - ---==:.!....:::.<..~-

70 RERCTOR TRIP (Sl<E.ET ZJ RE:CIIINOANT !

I I

I I

I r

_J

[-

I P*l3 I

TO P*7

. Lj ____

-'CSHE.E.T.... _)__,, __

RE.OUNl>ANT /

I I c:;.5 c*s.

Bl.OCH AUTOMATIC ROD WITHDRAWAL (Sl<*ET q)

TURBINE AUNSACK VI/I LOAD.REFERENCE C*3 0Vl.A'TEMPERTUR£ 6T (Z/3)

{SHEET 5)

NOT REDUNDANT

/

TO OEl't.A-r RE.MOTL f:\\£.F *'Z;;><{Jl'-f DISP-'ITCH 11\\JG.

(lJOTE 3)

{SY c:mw:11~)

NOT RCDUNOANl C*4 OVERPOWE.R AT (Z/3)

(SHEET&)

NOT REO\\llllDANl 1111£5:

I. >>e5E SIC>UI..S IHOlc>.TE M C..OSIIIG OF 11<1: STQ>

VAL'IES.

l'QSITICN OETECTICtl IS ACCCM'Lt9'fll BT 2 5"1Ttl'ES PE11 S11lP VALVE; 0£: fCR EAOi TRAIN.

1>£ LOGIC s,c.,. IS FCR 4 SllP VALVES.

tHE ACr<IIL NMlER OF Slllf" VALVES W.Y B( DI-.

2. ~s~~'.c>.TED IN REGMIJS m
3.

$\\C.t-V\\'1. UU:O '"TO &\\.OCM. fa1al,l'!,1\\-',-rOft L0.0-1:> IN.C'f\\'°"!,&.S,

'I.

OP£1C/5HIIT INDICATION IN (OMT~OL ROON.

1.

GlNERATOR MOTORING PROTEtllOM 5~0UI..D HCl O£f£Al THE.:!IO SEC. 0£1..A'T-G. Tl/£ ~EP rRfl" M IS <<.ou,w;:,,,,,n,y DtE//'GIWl W'9 R ~

/lrf!OUfi!:Jl1N1"1.Y A:twe'P-'O 24 V DC SUS. n,r; '24YIX eus NOPMPt.tr ~

r>t~

IF/'$1'£'1? TR1P !JOI.EIOD 50 T>IRr A,as, OF P0"1!.I? °"' r,,,: $15..,,i.._._, lltlW,r,,eCIIIM TUlfl!Jlf'I~ ~

~ ADQ(TlOAA\\. 0ET1'tl..ll':, A~'E. "-Vj,,,l\\..~'6Lt: FOA.

~?'~;zJ:~;<ii"_STl:M *R<>M G.A. X.

Df\\AIIIH(lu.tBILITl CLASS 2 sttaGCIIOEllWICEO AMENDMENT 99-01 JUNE 1999