xvc;-2a0qA-MS MAIN STOP VALVE
( SV-1)
XVT-73001-TB r.l XVT-73002-TB NOTE I XVT-73003-TB IPT-5608-HRI
- TB IPT-5608*HR2-TB STEAM INLET* - -- -- -
q90 PSIA BEFORE SEAT DRAIN.
REFER TO MOISTURE
"'i----**------REMOVAL ANO 542'F XVX*22825A SOLENOIO-OPERATED-.....i TEST VALVE STEM SEAL DISK DUMP VALVE ORIFICE*
0 109" DIA
$HUT-OFF VALVE* SET TO OPEN AT 500 l'.S.I.C.
XVM*22823A L..J EXTRACTION DIAGRAM
__...,_ STEAM OUTLET TO CONTROL VALVES REFER TO DIAGRAM OF
-** STEAM SEAL PIPING XVX*22824A SV!*FA ORIFICE 0.111Jq" DIA.
SOLENOID-OPERATED, FAST ACTING VALVE a._..,. ~
COMPUTER Y20010
~
SSPS-A, B SVl*L Tl XVG-2s0qs-MS MAIN STOP VALVE (SV-2)
$$$$$0GNSPEC$$$$$$$$$$$$$$$$$$$$$$$$$$$$
$$USERNAME$$$$$$$SYTIME$$$$$$
STEAM INLET* - -- -- -
q90 PSIA 11):J,~jli.,J__ FOR PRE-WARMING ONLY 11 ~IIV BEFORE SEAT DRAIN
- REFER TO MOISTURE 542"F 3 COIL SERVO VALVE XVM-22825B SV2-SVI DISK DUMP VALVE SHUT-OFF VALVE*
SET TO OPEN AT isoo P. s.1.0.
XVM-228238 REMOVAL ANO
-M
--EXTRACTION DIAGRAM
___ -.. ___...,_STEAM OUTLET TO CONTROL VALVES REFER TO DIAGRAM OF
--- STEAM SEAL PIPING XVX*22824B SV2-FA SOLENOID-OPERATED, FAST-ACTING VALVE
~
,..==-::, COMPUTER Y2002D
~
SSPS*A, B SV2-L T2 SV2*LT1 LEGEND OIL OR HYDRAULIC FLUID LINE SV2-L T3 xvc;-2s0qc-Ms MAIN STOP VALVE xvc;-2a0qo-Ms MAIN STOP VALVE ELECTRICAL <DUAL OR
--'00' MUL TIPLE LEADl I SV-3)
STEAM INLET- - -- -
II qg0 PSIA
~
542.F XVX-22825C STEM SEAL DISK DUMP VALVE ORIFICE*
0 109" DIA SHUT-OFF VALVE* SET TO OPEN AT 500 P.S.I.G.
XVM-22823C BEFORE SEAT DRAIN.
REFER TO MOISTURE
______ REMOVAL ANO EXTRACTION DIAGRAM
_______...., STEAM OUTLET TO CONTROL VALVES REFER TO DIAGRAM OF
_.,.._ STEAM SEAL PIPING XVX-22824C SV3-FA ORIFICE 0.109" DIA.
SOLENOID-OPERATED, fAST ACTING VALVE 0'
5*
10'
~~ ~COMPUTER Y2003D
~SSPS*A, B V3*L I 15' I SV-4)
STEAM INLET- - -- -
qa0 PSIA 542"F SOLENOID-OPERATED TEST VALVE XVX-228250 SV4*TS STEM SEAL DISK DUMP VALVE ORIFICE*
0 109" DIA SHUT-OFF VALVE* SET TO OPEN AT 500 P.S.I.G.
XVM-228230 BEFORE SEAT DRAIN.
REFER TO MOISTURE
______ REMOVAL AND EXTRACTION DIAGRAM
_______...,_STEAM OUTLET TO CONTROL VALVE$
REFER TO DIAGRAM OF
_ _,.,,..STEAM SEAL PIPING XVX-228240 SV4*FA ORIFICE 0.109" DIA.
SOLENOID-OPERATED, FAST ACTING VALVE
~
r.::=::-::, COMPUTER Y2004O
~
SSPS*A, B SV4*L Tl 5
4 3
2 l
6 NO.
'l/
RHM 5112/11 DOJ 115/811 RHM ll3/31/'l8 JTS lll!W'l6 AVN 2/'!j/J!j JMR TE BY AIR LINE STEAM LINE COMPONENTS SHOWN IN PHANTOM -
BY PURCHASER 1600 P.S.I.G. HYDRAULIC FLUID TO OPERATING DEVICES
.0 - 5 P.S.I.G. HYDRAULIC FLUID DRAIN 1600 P.S.!.G. HYDRAULIC FLUID TRIP SYSTEM 1600 P.S.I.G. HYDRAULIC FLUID TO JET OPERATING SIGNAL FROM ELECTRO-HYDRAULIC
~
CONTROL CABINET
~
vv ----
- NOTES, FEEDBACK SIGNAL TO ELECTRO-HYDRAULIC CONTROL CABINET I, SEE D-302-012 FOR FLOW DRAWING LOCATION.
SElTING INSTRUClfONS FOR CONTROL $YST£M LlkE-UP OIAGRAJi,4 SEE OWG NO f2$D2H6 FOR MAIN $TEAM VALVE SWITCH
&ETTfNG INSTRUC::TlONS SE£ OWG NO 254A9066 FOR SWITCH SOX DRAWINC SEE OWG NO 1,4£52;) ~ND 75:u1z5 REVISED PER ECR-505qz REVISED PER ECR505qze REVISED PER CGSS-00-0005 REVISED PER CGSS-q?-0662 REVISED PER CGSS-96-0571 REVISED PER ECR* 72833 R/N 12*013 REVISION MGR MGR MGR MGR MGR MGR CKD.BY GM AME JEG LEK JMW TMH t.E APPROVAL DRAWING LEGIBILITY CLASS 1 FSAR FIGURE 10.2-2 STOP VALVE 251R45Pl DESIGN ENGINEERING V. C. Sl.ttMER NUCLEAR STATION JENKINSVILLE C,
CHECKED LE APPROVAL A.V.N.
M.G.R.
J.M.W.