2 to Updated Final Safety Analysis Report, Figure 9.4-24, Rev. 18, Piping System Flow Diagram Chilled Water - to Cooling Coils B
ML22194A454
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 06/27/2022
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22194A236 List: ... further results
References
22-179
Download: ML22194A454 (1)


Text

14 13 12 11 10 9 8 7 6 5 4 3 2 1 SYSTEM DATA B-7 NORMAL UPSET OF

[$ BY REMARKS -842 GPM PSIG GPM PSIG vu 1 62 96 45 JAH 6" 6" 6" 2 51 96 45 JAH J 73 93 45 JAH A 4 50 103 45 JAH A 5 50 99 45 JAH 6" 6 37 88 45 JAH ROp49

..,. N  ::,

V 7 128 76 45 JAH V ,-,., / 26373-VU ID~>

NOTE5 .6.___ ,-,., '

1 8 59 72 45 JAH NOTE 5

~ TSC TSC ~'

9 31 87 45 JAH 10 29 77 45 JAH XPS-195-VU ESF SWGR 10B ROp49 / 2505X 152 ROp4 \ ROp4 2" ROOM UNIT "B" 26370-VU 6435B*VU 64398-VU 3/4" t1/2" 6 :--,1.:.:,_~'---. . .--IXJ,c]

~ X AH-8-V L ~JD-r\ 1~r{::a:J--_,,.;;,::;_.....:;..---+---I!1/2" I !1/2 3/4" Rop4 I '-------- 2" 13 3/4"/

R0p4 ROp 49 16387-VU \

ROp4 1---..--... ~~-,,~VENT 6431B-YU ROp49 6429B-VU

/63728-VU B

3/4" 76 IPX90688-HR-YU I VENT ~3/4...,, . . ."'3/4"",,,--1 "'"In B

ROp49 / ROp49 / PX N 16372-VU IPX90908-HR-VU 9090B I 152 151X 5 QR 26 - - - - - - - - - - - - - 1 N 3/4"

~

6" 151X m:~~

VENT I CHARGING/SI / ROp49 OVERFLOW' 3 II 2" PUMP ROOM "3 IPX90628-HR-VU 6"

'- 171 ~2" EXP. TANK "B"  !" !1/2"

~  : Ro 49 .

XTK-174B-VU XAH-18-VL l - - - -.... ..._-c.G--,--< 5 V I IL T-9006-HR-VU 118 GAL. I 6,, I I ROp4 /~NOTE 5 ROp4 ./

4" I

I L---7 63818-VU VTSC 3/4" \ IPX90988-HR-VU ROp49 -s~37~9,._B~-~vu.,,

I I___ J ___ T--1 OUTSIDE C.B. 1 I I INSIDE C.B. 4,, RKf16 4" I 21/2" 16382-VU I I I

~ r------ XPS-183B-VU C I

~NOTE 5 C l_ - - - - - - - - - _J Rop49 ___--y;:-:J-'4--1--,3/4".,-'-,

~ 6440B-VU - I NOTE 5 NOTE 5 VTsc 6"

NOTE 5 NOTE 5 (IID XPS-184B-VU ~TSC Tsc (s>Tsc Tsc t 21/2" I

XPS-1898-VUl RHR/SPRAY PUMP ROp4 ROOM UNIT "B' ~2" RELAY ROOM

!1/2" 1 l1/2" 2"

,\I . / 63618-VU !1/2" 2

8 - - - - - - . ; ; ,1/2~"--111----l'l,kl.,OI~

2,, UNIT "B" (STA UNIT 1l 2,,

XAH-138-AH ~ 2,,

v 11-,i,,~-1XH11-- 21/2"

~3-,,---+-,---....;;;..--D~........-l 1 1 XAH-48-VL  :::,,C:a::J---___;T!"---< 4 Rop11 / . . \ ROpll ROp4 / 3/4" \ R0p49 3/4" \ ROp49 VENT 3/4" ' ' ROp49 31,,

6399B-VU

!"  ::, 63638-VU IPX9102B-HR-VU IPX9060B-HR-VU X In 640IB-VU IPX9074B-HR*VU /

14

.,a- >ti;' "

In g

0. N D

ROp49 / / 0 "'

n:: "'N In In N

LO l!l D

NOTE 7

(\J

"'~

VENT 1" N

~

\n t- 3" 171

!1/2" 3"

3/4"~

V 3/4" ROp49 /

2" F

26368-VU 3" 3" 3"

6" E 4" 4" E

' ..,. VENT

"'~

~

0 "'

l" 25051152 LOJ\

ROn?

63958-VU\

NOTE 5 1

TSC CONTROL ROOM XPS*l88B1*VU \ <?-

NOTE 5 TSC ROp12 6393B-VU 6"

2505X 2505 r X;S-186B-VU 4

ROp49V \

26362-VU

~

ROp4 I+

/ROp4 6362A-VU 4

3 7*;,---------.----,...:...--r:.:::'lrCJl1XAH-128-A H ~

\ , 2~[ UNIT 'B' COIL *t 21/2,, \ 3

H>::J---,-----r--..-

4" \ ROp 4 j SW BOOSTER 2" PUMP AREA UNIT 'B" 63608-VU H-4 3" !1/2" 6446A-VU !1/2" ~ 2" l1/2" 3" l" 3/4" ',_ 3/4"  !"

0-13<84it!7-..::....,,.n..,...,..:::~----~:.:.'....,...... 1-,-.![11 XAH - 9 8- VL lfi I.Jlil::.:::1--.......1 - - - ~ 2 3"

ROp49

!PX90708-HR-VU / I" ROp4/1 6417B-VU \

R p49

! 3/4" '\ R0p4 I  !"

3" 3" F F ROp49 //PX IPX91088-HR-VU / '.._ _ !~198-VU IPX90888-HR-VU 90888 I

r _,

~OTE 5 PX 91088 ROp49

!PX9JIJ54B*HR-VU

//px 90548 0,

C NOTE 5 TI 90558 al CONTROL ROOM RKfl6 0:

VTSC TSC I 16383-VU w 2 ,~, UNIT "B" COIL #2 21/2" /XPS*188B2*VU al X 0

'-.....t.::1-.f: X A H-12 8 -AH l£ :H:.::i-.,-' "'"'

l!l VEN.;/ <(

w 0: 12',NOTE 5 N R0n7/' [ *~ w "' I

%"0.0. ~

l!l 0

6375B-VU  : 3/4" \ R0p49 3/4" 1 63768-VU <(

VTsc

~

N IPX90700-HR*VU 1 w N

_J I CL

!9 1

NOTES, NOT_E_5_ ,' ROp49 L _ -0NOTE 5 CL SC IPX9088D-HR-VU 9;:80 TSC z 9

J CJ) 0:
1. ALL EOU!PMENT TO BE SAFETY CLASS  :::J 26 UNLESS NOTED OTHER',i!SE f- 2"  !"
2. ALL SAFETY CLASS PIPING TO BE lN w

G ACCORDAfJCE WITH LINE SPEC 152N 0: G

3. ALL NON SAFETY CLASS PlPlNG TO BE IN ACCORDANCE WITH L!NE SPEC l5!X 6"
4. EXCEPT ',iHERE NOTED OTHERWISE. ALL ALARMS & INO!CA TING LIGHTS ARE LOCATED ON THE HVAC CONTROL BOARD (XCP-6210-AHI IN THE MAIN CONTROL ROOM
5. OPERA TOR !NIT !ATE !NPU T TO THE TSC COMPUTER THE ASSOCIATED 307 DRAWING SHALL
6. THE HYDROSTATIC PRESSURE LISTED ON THIS BE REVISED IN CONJUNCTION WITH REVISION TO THIS 302 IF THE CROSS ORA"ING lN THE OES!GN DATA BOX 1S PER HATCHED AREA IS AFFECTED.

SECTION XI OF THE ASME CODE, THE VALUE IS BASED ON DEAD HEAD PRESSURE AT THE PUMP DISCHARGE. THE VALUE OCES NOT INCLUDE H ELEVATION CORRECTIONS. H

?.CONNECTION CONTAINS PERMANENT SAMPLE CONNECTION. REFER TO !MS-22-1519 FOR 6" CETAILS. NOTE 5 NOTE 5 Tsc XPS-1918-VU Tse

8. ALL PIPING AND COMPONENT

!PX ROOT VALVES ARE NON SEE TYPICAL DEP!CTION AT DOWNSTREAM OF AFETY RELATED.

PX 91108.

1 2" /

f 2" BATTERY ROOM AIR HANDLING UNIT B 2"

...-....a.2'-'-1.....,.._~...,..,.3/4~,,:---~~XAH-248-AH~f-,-f;;(l---:: 1--;;,.----(F 6"

~

I 3/4" \ ROp49

!PX9046B*HR-VU /

3/4" I64438-VU ROpl0 THIS IS A NUCLEAR SAFETY RELATED DOCUMENT. NO DEVIATION SHALL BE 64458-VU PX ROp49 //PX INITIATED OR PERFORMED WITHOUT PRIOR J 90468 !PX9042B*HR-VU 90428 DOCUMENTATION AND WRITTEN APPROVAL J

RN 08-019 FSAR Figure 9.4-24 October 2008 SOUTH CAROLINA B.ECTRIC &GAS COMP/IIIY DRAWING LEGIBILITY CLASS 1 VIRGIL C. SUMMER NUCLEAR STATION SCE&G CAD ENHANCED PIPING SYSTEM FLOW DIAGRAM 6" CHILLED WATER - TO COOLING COILS 2"

5 "Bu 6 ATM 107 15 li.05*95 SRM REVISED PER MRF -22114 MGR DJL K 5 123 54 136 OJL COIL IN ITYP) 6" 14 04-0J.95 SRM REVISED PER MRF-22594 & MGR CHR 6SCE:&G DESIGN ENGINEERING K V. C- SUMMER NUCLEAR STATfON JENKINSVILLE, S. C, 4 123 45 136 DJL COIL IN ITYPl SRM REVISED PER MRF-22114 MGR DJL A SCANA COUP',HY fID PSIG NORMAL "F PSIG "F UPSET DURATION HYDRO BY CKD REMARKS -' .-'

Cl 00 18 17 8/21/08 RHM 06/14/04 JTS REVISED PER ECR-71196 CAOD ENHANCED PER ECR-50239 MGR MGR LF DDJ l.

A.V.N.

MADE CHECKED D.V.W.

3.

LE APRROVAL D.J.C.

16 i0/i9/0I DDJ REVISED PER ECR-70028 MGR DDJ ~

DESIGN DATA LE NO SC/\LE D-302-843 18 NO. DATE BY REVISION CKD. 8Y APPROVAL ORA\/ [NG NUMBER SHT, NUMBER REV