ML21140A407
ML21140A407 | |
Person / Time | |
---|---|
Issue date: | 05/20/2021 |
From: | NRC |
To: | NRC/NMSS/DREFS |
References | |
Download: ML21140A407 (163) | |
Text
From: Dozier, Tami Sent: Thursday, May 20, 2021 4:19 PM To: AdvancedReactors-GEISDocsPEm Resource
Subject:
Unified Facilities Criteria: Dewatering and Groundwater Control Attachments: DOD 2004 ufc_3_220_05.pdf
Hearing Identifier: AdvancedReactors_GEIS_Public Email Number: 16 Mail Envelope Properties (BY3PR09MB7585859841D603D0C0009B9AF42A9)
Subject:
Unified Facilities Criteria: Dewatering and Groundwater Control Sent Date: 5/20/2021 4:18:39 PM Received Date: 5/20/2021 4:18:45 PM From: Dozier, Tami Created By: Tamsen.Dozier@nrc.gov Recipients:
"AdvancedReactors-GEISDocsPEm Resource"
<AdvancedReactors-GEISDocsNPR.Resource3@nrc.gov>
Tracking Status: None Post Office: BY3PR09MB7585.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 3 5/20/2021 4:18:45 PM DOD 2004 ufc_3_220_05.pdf 2986277 Options Priority: Normal Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
UFC 3-220-05 16 January 2004 UNIFIED FACILITIES CRITERIA (UFC)
DEWATERING AND GROUNDWATER CONTROL APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED
UFC 3-220-05 16 January 2004 UNIFIED FACILITIES CRITERIA (UFC)
DEWATERING AND GROUNDWATER CONTROL Any copyrighted material included in this UFC is identified at its point of use.
Use of the copyrighted material apart from this UFC must have the permission of the copyright holder.
U.S. ARMY CORPS OF ENGINEERS (Preparing Activity)
NAVAL FACILITIES ENGINEERING COMMAND AIR FORCE CIVIL ENGINEER SUPPORT AGENCY Record of Changes (changes are indicated by \1\ ... /1/)
Change No. Date Location This UFC supersedes TM 5-818-5, dated 15 November 1983. The format of this UFC does not conform to UFC 1-300-01; however, the format will be adjusted to conform at the next revision.
The body of this UFC is the previous TM 5-818-5, dated 15 November 1983.
1
UFC 3-220-05 16 January 2004 FOREWORD
\1\
The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD(AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other customers where appropriate. All construction outside of the United States is also governed by Status of forces Agreements (SOFA), Host Nation Funded Construction Agreements (HNFA), and in some instances, Bilateral Infrastructure Agreements (BIA.)
Therefore, the acquisition team must ensure compliance with the more stringent of the UFC, the SOFA, the HNFA, and the BIA, as applicable.
UFC are living documents and will be periodically reviewed, updated, and made available to users as part of the Services responsibility for providing technical criteria for military construction. Headquarters, U.S. Army Corps of Engineers (HQUSACE), Naval Facilities Engineering Command (NAVFAC), and Air Force Civil Engineer Support Agency (AFCESA) are responsible for administration of the UFC system. Defense agencies should contact the preparing service for document interpretation and improvements. Technical content of UFC is the responsibility of the cognizant DoD working group. Recommended changes with supporting rationale should be sent to the respective service proponent office by the following electronic form: Criteria Change Request (CCR). The form is also accessible from the Internet sites listed below.
UFC are effective upon issuance and are distributed only in electronic media from the following source:
x Whole Building Design Guide web site http://dod.wbdg.org/.
Hard copies of UFC printed from electronic media should be checked against the current electronic version prior to use to ensure that they are current.
AUTHORIZED BY:
DONALD L. BASHAM, P.E. DR. JAMES W WRIGHT, P.E.
Chief, Engineering and Construction Chief Engineer U.S. Army Corps of Engineers Naval Facilities Engineering Command KATHLEEN I. FERGUSON, P.E. Dr. GET W. MOY, P.E.
The Deputy Civil Engineer Director, Installations Requirements and DCS/Installations & Logistics Management Department of the Air Force Office of the Deputy Under Secretary of Defense (Installations and Environment) 2
ARMY TM 5-818-5 NAVY NAVFAC P-418 AIR FORCE AFM 88-5, Chap 6 DEWATERING AND GROUNDWATER CONTROL DEPARTMENTS OF THE ARMY, THE NAVY, AND THE AIR FORCE NOVEMBER 1983
REPRODUCTION AUTHORIZATION/RESTRICTIONS This manual has been prepared by or for the Government and, except to the ex-tent indicated below, is public property and not subject to copyright.
Copyrighted material included in the manual has been used with the knowledge and permission of the proprietors and is acknowledged as such at point of use.
Anyone wishing to make further use of any copyrighted material, by itself and apart from this text, should seek necessary permission directly from the proprie-tors.
Reprints or republications of this manual should include a credit substantially as follows: Joint Departments of the Army, the Air Force, and the Navy, USA, Technical Manual TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418, Dewatering and Groundwater Control.
If the reprint or republication includes copyrighted material, the credit should also state: Anyone wishing to make further use of copyrighted material, by itself and apart from this text, should seek necessary permission directly from the pro-prietors.
TM 5-818-5 AFM 88-5, Chap. 6 NAVFAC P-418 C-1 Change HEADQUARTERS DEPARTMENTS OF THE ARMY, AIR FORCE, AND NAVY No. 1 WASHINGTON , DC 27 June 1985 DEWATERING AND GROUNDWATER CONTROL TM 5-818-5/AFM 88-5, Chapter 6/NAVFAC P-418, 15 November 1983 is changed as follows:
- 1. Remove old pages and insert new pages as indicated below. New or changed material is indicated by a verti-cal bar in the margin of the page.
Remove pages Insert pages i and ii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i and iii A-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
- 2. File this change sheet in front of the publication for reference purposes.
By Order of the Secretaries of the Army, the Air Force, and the Marine Corps:
JOHN A. WICKHAM, JR.
General, United States Army Official: Chief of Staff DONALD J. DELANDRO Brigadier General, United States Army The Adjutant General CHARLES A. GABRIEL General, United States Air Force Official: Chief of Staff EARL T. OLOUGHLIN General, United States Air Force, Commander, Air Force Logistics Command H.A. HATCH Lieutenant General, Marine Corps Deputy Chief of Staff, Installation and Logistics Command
- TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 TECHNICAL MANUAL HEADQUARTERS No. 5-818-5 DEPARTMENT OF THE ARMY, AIR FORCE MANUAL THE AIR FORCE, NO. 88-5, Chapter 6 AND THE NAVY NAVY MANU AL No. P-418 WASHINGTON , DC 15 November 1983 DEWATERING AND GROUNDWATER CONTROL Paragraph Page CHAPTER 1. INTRODUCTION Purpose and scope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l-1 l-1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l-2 l-1 Construction dewatering. . . . . . . . . . . . . . . . . . . . . . . . . . l-3 l-1 Permanent groundwater control . . . . . . . . . . . . . . . . . . . . l-4 l-2
- 2. METHODS FOR DEWATERING, PRESSURE RELIEF, AND SEEPAGE CUTOFF General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-1 Types and source of seepage . . . . . . . . . . . . . . . . . . . . . . . 2-2 2-1 Sumps and ditches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2-1 Wellpoint systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 2-2 Deep-well systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 2-4 Vertical sand drains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 2-5 Electroosmosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 2-5 Cutoffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 2-5 Summary of groundwater control methods. . . . . . . . . . . . 2-9 2-8 Selection of dewatering system. . . . . . . . . . . . . . . . . . . . . 2-10 2-8
- 3. GEOLOGIC, SOIL, AND GROUNDWATER INVESTI-GATIONS General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-1 Geologic and soil conditions. . . . . . . . . . . . . . . . . . . . . . . . 3-2 3-1 Groundwater characteristics. . . . . . . . . . . . . . . . . . . . . . . 3-3 3-4 Permeability of pervious strata. . . . . . . . . . . . . . . . . . . . . 3-4 3-4 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 3-8 Surfacewater.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 3-8
- 4. DESIGN OF DEWATERING, PRESSURE RELIEF, AND GROUNDWATER CONTROL SYSTEMS Analysis of groundwater flow . . . . . . . . . . . . . . . . . . . . . . 4-1 4-1 Mathematical and model analyses. . . . . . . . . . . . . . . . . . . 4-2 4-1 Flow-net analyses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 4-29 Electrical analogy seepage models. . . . . . . . . . . . . . . . . . . 4-4 4-29 Numerical analyses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 4-34 Wellpoints, wells, and filters. . . . . . . . . . . . . . . . . . . . . . . 4-6 4-34 Pumps, headers, and discharge pipes. . . . . . . . . . . . . . . . . 4-7 4-36 Factors of safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 4-40 Dewatering open excavations . . . . . . . . . . . . . . . . . . . . . . 4-9 4-42 Dewatering shafts and tunnels . . . . . . . . . . . . . . . . . . . . . 4-10 4-47 Permanent pressure relief systems . . . . . . . . . . . . . . . . . . 4-11 4-48 Freezing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 4-48 Control of surface water . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 4-49
- 5. INSTALLATION OF DEWATERING AND GROUND-WATER CONTROL SYSTEMS General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 5-1 Deep-well systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 5-1 Wellpoint systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 5-2 Vertical sand drains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 5-5 Cutoffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5 5-5 Piezometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6 5-6
- 6. OPERATION AND PERFORMANCE CONTROL General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 6-1 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 6-1 Control and evaluation of performance. . . . . . . . . . . . . . . 6-3 6-2
- 7. CONTRACT SPECIFICATIONS General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 7-1
- This manual supersedes TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418, April 1971.
TM 5-815-5/AFM 88-5, Chap 6/NAVFACP-418 Paragraph Page Types of specifications . . . . . . . . . . 7-2 7-1 Data to be included in specifications . . . . . 7-3 7-2 Dewatering requirements and specifications . . . 7-4 7-2 Measurement and payment . . . . . . . . 7-5 7-3 Examples of dewatering specifications . . . . . . 7-4 7-3 APPENDIX A. REFERENCES AND BIBLIOGRAPHY . . . . . . . . . . A-1 B. NOTATIONS . . . . . . . . . . . . . . . . . . . . . B-1 C. FIELD PUMPING TESTS . . . . . . . . . . . . . . . . . . . C-1 D. EXAMPLES OF DESIGN OF DEWATERING AND PRES-SURE RELIEF SYSTEMS . . . . . . . . . . . . . . . D-1 E. TRANSFORMATION OF ANISOTROPIC SOIL CONDITIONS TO ISOTROPIC SOIL CONDITIONS . . . . . . . . . . . E-1 F. WELL AND TOTAL DISCHARGE MEASUREMENTS . . F-1 G. EXAMPLES OF DETAILED DEWATERING SPECIFICA- G-1 TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LIST OF FIGURES Figure Page 1-1 Installation of piezometers for determining water table and arte-sian hydrostatic pressure . . . . . . . . . . . . . . . l-2 l-2 Permanent groundwater control system . . . . . . . . . . . . l-3 2-1 Dewatering open excavation by ditch and sump 2-2 2-2 Self-jetting wellpoint . . . . . . . . . . . 2-3 2-3 Use of wellpoints where submergence is small . . . 2-4 2-4 Drainage of an open deep cut by means of a multistage wellpoint system . . . . . . . . . . . . . . . . . . . . . . . . 2-4 2-5 Vacuum wellpoint system . . . . . . . . . 2-5 2-6 Jet-eductor wellpoint system for dewatering a shaft . . . . . 2-6 2-7 Deep-well system for dewatering an excavation in sand . . 2-7 2-8 Deep wells with auxiliary vacuum system for dewatering a shaft in stratified materials. . . . . . . . . . . . . 2-8 2-9 Sand drains for dewatering a slope . . . . . . . . . . 2-9 2-10 Electra-osmotic wellpoint system for stabilizing an excavation slope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 2-11 Grout curtain or cutoff trench around an excavation. . 2-10 2-12 Dewatering systems applicable to different soils . . . 2-13 2-13 Recharge of groundwater to prevent settlement of a building as a result of dewatering operations . . . . . . . . . 2-14 3-1 Geologic profile developed from geophysical explorations . . . . . 3-2 3-2 Permeameters: (a) constant head and (b) falling head . . . 3-3 3-3 Specific yield of water-bearing sands versus D10 South Coastal Basin, California . . . . . . . . . . . . . . 3-4 3-4 D 10 versus in situ coefficient of permeability-Mississippi River Valley and Arkansas River Valley . . . . . . . . . . . 3-6 3-5 Formulas for determining permeability from field falling head tests . . . . . . . . . . . . . . . . . . . . . . . 3-7 3-6 Inches of rainfall during 10 and 30-minute and l-hour periods . . 3-8 4-1 Flow and head for fully penetrating line slot; single-line source; artesian, gravity, and combined Flows . . . . . . . 4-2 4-2 Height of free discharge surface h,; gravity flow . . . 4-3 4-3 Flow and head for partially penetrating line slot; single-line source; artesian, gravity, and combined flows . . . . . . . . 4-4 4-4 Flow and head for fully and partially penetrating line slot; two-line source; artesian and gravity flows . . . . . . . 4-5 4-5 Flow and head (midway) for two partially penetrating slots; two-line source; artesian and gravity flows. . . . . . 4-6 4-6 Flow and head for fully and partially penetrating circular slots; circular source; artesian flow . . . . . . . . . . . . . 4-7 4-7 Head at center of fully and partially penetrating circular slots; cir-cular source; artesian flow . . . . . . . 4-8 4-8 Flow and drawdown at slot for fully and partially penetrating rec-tangular slots; circular source; artesian flow . . . . 4-9 4-9 Head within a partially penetrating rectangular slot; circular source; artesian flow . . . . . . . . . . 4-10 4-10 Flow and drawdown for fully and partially penetrating single wells; circular source; artesian flow . . . . . . . . . . 4-11 ii Change 1
TM 5-815-5/AFM 88-5, Chap 6/NAVFACP-418 Figure Page 4-11 Flow and drawdown for fully and partially penetrating single wells; circular source; gravity flow 4-12 4-12 Flow and drawdown for fully penetrating single well; circular source; combined artesian and gravity flows 4-13 iii Change
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 CHAPTER 1 INTRODUCTION 1-1. Purpose and scope. This manual provides (1) Intercepting seepage that would otherwise guidance for the planning, design, supervision, con- emerge from the slopes or bottom of an excavation.
struction, and operation of dewatering and pressure (2) Increasing the stability of excavated slopes relief systems and of seepage cutoffs for deep excava- and preventing the loss of material from the slopes or tions for structures. It presents: description of various bottom of the excavation.
methods of dewatering and pressure relief; techniques (3) Reducing lateral loads on cofferdams.
for determining groundwater conditions, characteris- (4) Eliminating the need for, or reducing, air pres-tics of pervious aquifers, and dewatering require- sure in tunneling.
ments; guidance for specifying requirements for de- (5) Improving the excavation and backfill char-watering and seepage control measures; guidance for acteristics of sandy soils.
determining the adequacy of designs and plans pre- Uncontrolled or improperly controlled groundwater pared by contractors; procedures for designing, install- can, by hydrostatic pressure and seepage, cause piping, ing, operating, and checking the performance of de- heave, or reduce the stability of excavation slopes or watering systems for various types of excavations; and foundation soils so as to make them unsuitable for sup-descriptions and design of various types of cutoffs for porting the structure. For these reasons, subsurface controlling groundwater. construction should not be attempted or permitted without appropriate control of the groundwater and 1-2. General. (subsurface) hydrostatic pressure.
- a. It will generally be the responsibility of the con- b. Influence of excavation characteristics. The loca-tractor to design, install, and operate dewatering and tion of an excavation, its size, depth, and type, such as groundwater control systems. The principal usefulness open cut, shaft, or tunnel, and the type of soil to be of this manual to design personnel will be those por- excavated are important considerations in the selec-tions devoted to selecting and specifying dewatering tion and design of a dewatering system. For most and groundwater control systems. The portions of the granular soils, the groundwater table during construc-manual dealing with design considerations should fa- tion should be maintained at least 2 to 3 feet below the cilitate review of the contractors plans for achieving slopes and bottom of an excavation in order to ensure the desired results. dry working conditions. It may need to be main-
- b. Most of the analytical procedures set forth in this tained at lower depths for silts (5 to 10 feet below sub-manual for groundwater flow are for steady-state grade) to prevent water pumping to the surface and flow and not for unsteady-state flow, which occurs making the bottom of the excavation wet and spongy.
during the initial phase of dewatering. Where such deep dewatering provisions are necessary,
- c. Some subsurface construction may require de- they should be explicitly required by the specifications watering and groundwater control procedures that are as they greatly exceed normal requirements and would not commonly encountered by construction contract- not otherwise be anticipated by contractors.
ors, or the dewatering may be sufficiently critical as to (1) Where the bottom of an excavation is under-affect the competency of the foundation and design of lain by a clay, silt, or shale stratum that is underlain the substructure. In these cases, it may be desirable to by a pervious formation under artesian pressure (fig.
design and specify the equipment and procedures to be 1-1), the upward pressure or seepage may rupture the used and to accept responsibility for results obtained. bottom of the excavation or keep it wet even though This manual should assist design personnel in this the slopes have been dewatered. Factor of safety con-work. siderations with regard to artesian pressure are dis-cussed in paragraph 4-8.
1-3. Construction dewatering. (2) Special measures may be required for excava-
- a. Need for groundwater control. Proper control of tions extending into weathered rock or shale where groundwater can greatly facilitate construction of sub- substantial water inflow can be accommodated with-surface structures founded in, or underlain by, per- out severe erosion. If the groundwater has not been vious soil strata below the water table by: controlled by dewatering and there is appreciable flow 1-1
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from "Foundation Engineering," G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 1-1. Installation of piezometers for determining water table and artesian hydrostatic pressure.
or significant hydrostatic pressures within the rock or 1-4. Permanent groundwater control.
shale deposit, rock anchors, tiebacks, and lagging or Many factors relating to the design of a temporary de-bracing may be required to prevent heave or to support watering or pressure relief system are equally applica-exposed excavation slopes. ble to the design of permanent groundwater control (3) An important facet of dewatering an excava- systems. The principal differences are the require-tion is the relative risk of damage that may occur to ments for permanency and the need for continuous the excavation, cofferdam, or foundation for a struc- operation. The requirements for permanent drainage ture in event of failure of the dewatering system. The systems depend largely on the structural design and method of excavation and reuse of the excavated soil operational requirements of the facility. Since perma-may also have a bearing on the need for dewatering. nent groundwater control systems must operate con-These factors, as well as the construction schedule, tinuously without interruption, they should be con-must be determined and evaluated before proceeding servatively designed and mechanically simple to avoid with the design of a dewatering system. the need for complicated control equipment subject to
- c. Groundwater control methods. Methods for con- failure and the need for operating personnel. Perma-trolling groundwater may be divided into three cate- nent drainage systems should include provisions for gories: inspection, maintenance, and monitoring the behavior (1) Interception and removal of groundwater from of the system in more detail than is usually required the site by pumping from sumps, wells, wellpoints, or for construction dewatering systems. Permanent sys-drains. This type of control must include consideration tems should be conservatively designed so that satis-of a filter to prevent migration of fines and possible factory results are achieved even if there is a rise in development of piping in the soil being drained. the groundwater level in the surrounding area, which (2) Reduction of artesian pressure beneath the may occur if water supply wells are shut down or if the bottom of an excavation. efficiency of the dewatering system decreases, as may (3) Isolation of the excavation from the inflow of happen if bacteria growth develops in the filter sys-groundwater by a sheet-pile cutoff, grout curtain, tem. An example of a permanent groundwater control slurry cutoff wall, or by freezing. system is shown in figure 1-2.
1-2
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Fruco & Associates, Inc.)
U.S. Army Corps of Engineers Figure 1-2. Permanent groundwater control system.
1-3
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 CHAPTER 2 METHODS FOR DEWATERING, PRESSURE RELIEF, AND SEEPAGE CUTOFF 2-1. General. water table and soil formations in the area and the
- a. Temporary dewatering systems. Dewatering and drawdown required to dewater the excavation.
control of groundwater during construction may be ac- b. Source of seepage flow. The source and distance complished by one or a combination of methods de- L* to the source of seepage or radius of influence R scribed in the following paragraphs. The applicability must be estimated or determined prior to designing or of different methods to various types of excavations, evaluating a dewatering or drainage system.
groundwater lowering, and soil conditions is also dis- (1) The source of seepage depends on the geo-cussed in these paragraphs. Analysis and design of de- logical features of the area, the existence of adjacent watering pressure relief and groundwater control sys- streams or bodies of water, the perviousness of the tems are described in chapter 4. sand formation, recharge, amount of drawdown, and duration of pumping. The source of seepage may be a
- b. Permanent drainage systems. The principles and nearby stream or lake, the aquifer being drained, or methods of groundwater control for permanent struc-both an adjacent body of water and storage in the tures are similar to those to be described for construc-aquifer.
tion projects. A method often used for permanent groundwater control consists of relief wells (to be dis- (2) Where the site is not adjacent to a river or lake, the source of seepage will be from storage in the cussed subsequently in detail) installed beneath and formation being drained and recharged from rainfall adjacent to the structure, with drainage blankets be-over the area. Where this condition exists, flow to the neath and surrounding the structure at locations below area being dewatered can be computed on the assump-the water table as shown previously in figure 1-2. The tion that the source of seepage is circular and at a dis-water entering the wells and drainage blanket is carried through collector pipes to sumps, pits, or man- tance R. The radius of influence R is defined as the holes, from which it is pumped or drained. Permanent radius of the circle beyond which pumping of a de-watering system has no significant effect on the origi-groundwater control may include a combination of wells, cutoffs, and vertical sand drains. Additional in- nal groundwater level or piezometric surface (see para 4-2a(3)).
formation on the design of permanent drainage sys-tems for buildings may be found in TM 5-818-1/AFM (3) Where an excavation is located close to a river 88-3, Chapter 7; TM 5-818-4/AFM 88-5, Chapter 5; or shoreline in contact with the aquifer to be de-and TM 5-818-6/AFM 88-32. (See app. A for ref- watered, the distance to the effective source of seepage L, if less than R/2, may be considered as being approxi-erences.)
mately the near bank of the river; if the distance to the 2-2. Types and source of seepage. riverbank or shoreline is equal to about R/2, or greater, the source of seepage can be considered a circle with a
- a. Types of seepage flow. Types of seepage flow are tabulated below: radius somewhat less than R.
(4) Where a line or two parallel lines of *wells are Type of flow Flow characteristics installed in an area not close to a river, the source of Artesian Seepage through the previous aquifer is confined seepage may be considered as a line paralleling the line between two or more impervious strata, and of wells.
the piezometric head within the previous aquifer is above the top of the pervious aqui- 2-3. Sumps and ditches.
fer (fig. 1-2).
Gravity The surface of the water table is below the top of a. Open excavations. An elementary dewatering the pervious aquifer (fig. 1-2). procedure involves installation of ditches, French drains, and sumps within an excavation, from which For some soil configurations and drawdowns, the flow water entering the excavation can be pumped (fig.
may be artesian in some areas and gravity in other 2-1). This method of dewatering generally should not areas, such as near wells or sumps where drawdown occurs. The type of seepage flow to a dewatering sys- *For convenience, symbols and unusual abbreviations are listed tem can be determined from a study of the ground- in the Notation (app B).
2-1
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards. ed.. 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 2-1. Dewatering open excavation by ditch and sump.
be considered where the groundwater head must be cable to a wide range of excavations and groundwater lowered more than a few feet, as seepage into the ex- conditions.
cavation may impair the stability of excavation slopes a. Conventional wellpoint systems. A conventional or have a detrimental effect on the integrity of the wellpoint system consists of one or more stages of foundation soils. Filter blankets or drains may be in- wellpoints having 11/2 or 2-inch-diameter riser pipes, cluded in a sump and ditch system to overcome minor installed in a line or ring at spacings between about 3 raveling and facilitate collection of seepage. Dis- and 10 feet, with the risers connected to a common advantages of a sump dewatering system are slowness header pumped with one or more wellpoint pumps.
in drainage of the slopes; potentially wet conditions Wellpoints are small well screens composed of either during excavation and backfilling, which may impede brass or stainless steel mesh, slotted brass or plastic construction and adversely affect the subgrade soil; pipe, or trapezoidal-shaped wire wrapped on rods to space required in the bottom of the excavation for form a screen. They generally range in size from 2 to 4 drains, ditches, sumps, and pumps; and the frequent inches in diameter and 2 to 5 feet in length and are lack of workmen who are skilled in the proper con- constructed with either closed ends or self-jetting tips struction or operation of sumps. as shown in figure 2-2. They may or may not be sur-
- b. Cofferdams. A common method of excavating rounded with a filter depending upon the type of soil below the groundwater table in confined areas is to drained. Wellpoint screens and riser pipes may be as drive wood or steel sheet piling below subgrade ele- large as 6 inches and as long as 25 feet in certain situa-vation, install bracing, excavate the earth, and pump tions. A wellpoint pump uses a combined vacuum and out any seepage that enters the cofferdammed area. a centrifugal pump connected to the header to produce (1) Dewatering a sheeted excavation with sumps a vacuum in the system and to pump out the water and ditches is subject to the same limitations and seri- that drains to the wellpoints. One or more sup-ous disadvantages as for open excavations. However, plementary vacuum pumps may be added to the main the danger of hydraulic heave in the bottom of an ex- pumps where additional air handling capacity is re-cavation in sand may be reduced where the sheeting quired or desirable. Generally, a stage of wellpoints can be driven into an underlying impermeable stra- (wellpoints connected to a header at a common eleva-tum, thereby reducing the seepage into the bottom of tion) is capable of lowering the groundwater table the excavation. about 15 feet; lowering the groundwater more than 15 (2) Excavations below the water table can some- feet generally requires a multistage installation of times be successfully made using sheeting and sump wellpoints as shown in figures 2-3 and 2-4. A well-pumping. However, the sheeting and bracing must be point system is usually the most practical method for designed for hydrostatic pressures and reduced toe dewatering where the site is accessible and where the support caused by upward seepage forces. Covering excavation and water-bearing strata to be drained are the bottom of the excavation with an inverted sand not too deep. For large or deep excavations where the and gravel filter blanket will facilitate construction depth of excavation is more than 30 or 40 feet, or and pumping out seepage water. where artesian pressure in a deep aquifer must be re-duced, it may be more practical to use eductor-type 2-4. Wellpoint systems. Wellpoint systems are wellpoints or deep wells (discussed subsequently) with a commonly used dewatering method as they are appli- turbine or submersible pumps, using wellpoints as a 2-2
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 Figure 2-2. Self-jetting wellpoint.
2-3
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 (From Foundation Engineering, G. A. Leonards, ed., 1962. McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 2-3. Use of wellpoints where submergence is small.
supplementary method of dewatering if needed. Well- c. Jet-eductor wellpoint systems. Another type of points are more suitable than deep wells where the dewatering system is the jet-eductor wellpoint system submergence available for the well screens is small (fig. 2-6), which consists of an eductor installed in a (fig. 2-3) and close spacing is required to intercept small diameter well or a wellpoint screen attached to a seepage. jet-eductor installed at the end of double riser pipes, a
- b. Vacuum wellpoint systems. Silts and sandy silts pressure pipe to supply the jet-eductor and another (D10 0.05 millimetre) with a low coefficient of per- pipe for the discharge from the eductor pump. Eductor meability (k = 0.1 x 10-4 to 10 x 10-4 centimetres wellpoints may also be pumped with a pressure pipe per second) cannot be drained successfully by gravity within a larger return pipe. This type of system has methods, but such soils can often be stabilized by a the advantage over a conventional wellpoint system of vacuum wellpoint system. A vacuum wellpoint system being able to lower the water table as much as 100 feet is essentially a conventional well system in which a from the top of the excavation. Jet-eductor wellpoints partial vacuum is maintained in the sand filter around are installed in the same manner as conventional well-the wellpoint and riser pipe (fig 2-5). This vacuum will points, generally with a filter as required by the foun-increase the hydraulic gradient producing flow to the dation soils. The two riser pipes are connected to sep-wellpoints and will improve drainage and stabilization arate headers, one to supply water under pressure to of the surrounding soil. For a wellpoint system, the net the eductors and the other for return of flow from the vacuum at the wellpoint and in the filter is the vacuum wellpoints and eductors (fig. 2-6). Jet-eductor well-in the header pipe minus the lift or length of the riser point systems are most advantageously used to dewa-pipe. Therefore, relatively little vacuum effect can be ter deep excavations where the volume of water to be obtained with a wellpoint system if the lift is more pumped is relatively small because of the low permea-than about 15 feet. If there is much air loss, it may be bility of the aquifer.
necessary to provide additional vacuum pumps to en-sure maintaining the maximum vacuum in the filter 2-5. Deep-well systems.
column. The required capacity of the water pump is, of a. Deep wells can be used to dewater pervious sand course, small. or rock formations or to relieve artesian pressure be-(From Soils Mechanics in Engineering Practice, by K. Terzaghi and R. B. Peck, 1948, Wiley & Sons, Inc. Used with permission of Wiley & Sons, Inc.)
Figure 2-4. Drainage of an open deep cut by means of a multistage wellpoint system.
2-4
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 vacuum capacity to ensure efficient operations of the system.
2-6. Vertical sand drains. Where a stratified semipervious stratum with a low vertical permeability overlies a pervious stratum and the groundwater table has to be lowered in both strata, the water table in the upper stratum can be lowered by means of sand drains as shown in figures 2-9. If properly designed and in-stalled, sand drains will intercept seepage in the upper stratum and conduct it into the lower, more permeable stratum being dewatered with wells or wellpoints.
Sand drains consist of a column of pervious sand placed in a cased hole, either driven or drilled through the soil, with the casing subsequently removed. The ca-pacity of sand drains can be significantly increased by installation of a slotted 1% or 2-inch pipe inside the sand drain to conduct the water down to the more per-Note: Vacuum in header = 25 ft; vacuum vious stratum.
in filter and soil in vicinity of well-point = approximately 10 ft. 2-7. Electra-osmosis. Some soils, such as silts, clayey silts, and clayey silty sands, at times cannot be (From Foundation Engineering, G. A. Leonards, ed., dewatered by pumping from wellpoints or wells. How-1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.) ever, such soils can be drained by wells or wellpoints combined with a flow of direct electric current Figure 2-5. Vacuum wellpoint system. through the soil toward the wells. Creation of a hy-draulic gradient by pumping from the wells or well-neath an excavation. They are particularly suited for points with the passage of direct electrical current dewatering large excavations requiring high rates of through the soil causes the water contained in the soil pumping, and for dewatering deep excavations for voids to migrate from the positive electrode (anode) to dams, tunnels, locks, powerhouses, and shafts. Excava- the negative electrode (cathode). By making the cath-tions and shafts as deep as 300 feet can be dewatered ode a wellpoint, the water that migrates to the cathode by pumping from deep wells with turbine or submersi- can be removed by either vacuum or eductor pumping ble pumps. The principal advantages of deep wells are (fig. 2-10).
that they can be installed around the periphery of an 2-8. Cutoffs. Cutoff curtains can be used to stop or excavation and thus leave the construction area unem- minimize seepage into an excavation where the cutoff cumbered by dewatering equipment, as shown in fig- can be installed down to an impervious formation.
ure 2-7, and the excavation can be predrained for its Such cutoffs can be constructed by driving steel sheet full depth. piling, grouting existing soil with cement or chemical
- b. Deep wells for dewatering are similar in type and grout, excavating by means of a slurry trench and construction to commercial water wells. They com- backfilling with a plastic mix of bentonite andsoil, in-monly have a screen with a diameter of 6 to 24 inches stalling a concrete wall, possibly consisting of overlap-with lengths up to 300 feet and are generally installed ping shafts, or freezing. However, groundwater within with a filter around the screen to prevent the infiltra- the area enclosed by a cutoff curtain, or leakage tion of foundation materials into the well and to im- through or under such a curtain, will have to be prove the yield of the well. pumped out with a well or wellpoint system as shown
- c. Deep wells may be used in conjunction with a vac- in figure 2-11.
uum system to dewater small, deep excavations for a. Cement and chemical grout curtains. A cutoff tunnels, shafts, or caissons sunk in relatively fine- around an excavation in coarse sand and gravel or por-grained or stratified pervious soils or rock below the ous rock can be created by injecting cement or chem-groundwater table. The addition of a vacuum to the ical grout into the voids of the soil. For grouting to be well screen and filter will increase the hydraulic grad- effective, the voids in the rock or soil must be large ient to the well and will create a vacuum within the enough to accept the grout, and the holes must be close surrounding soil that will prevent or minimize seepage enough together so that a continuous grout curtain is from perched water into the excavation. Installations obtained. The type of grout that can be used depends of this type, as shown in figure 2-8, require adequate upon the size of voids in the sand and gravel or rock to 2-5
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S Army Corps of Engineers Figure 2-6. Jet-eductor wellpoint system for dewatering a shaft.
2-6
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Army Corps of Engineers Figure 2-7 Deep-well system for dewatering an excavation in sand.
be grouted. Grouts commonly used for this purpose are concreted in sections. These walls can be reinforced portland cement and water; cement, bentonite, an ad- and are sometimes incorporated as a permanent part mixture to reduce surface tension, and water; silica of a structure.
gels; or a commercial product. Generally, grouting of d. Steel sheet piling. The effectiveness of sheet pil-fine or medium sand is not, very effective for blocking ing driven around an excavation to reduce seepage de-seepage. Single lines of grout holes are also generally pends upon the perviousness of the soil, the tightness ineffective as seepage cutoffs; three or more lines are of the interlocks, and the length of the seepage path.
generally required Detailed information on chemical Some seepage through the interlocks should be expect-grouting and grouting methods is contained in TM ed. When constructing small structures in open water, 5-818-6/AFM 88-32 and NAVFAC DM 7.3. it may be desirable to drive steel sheet piling around
- b. Slurry walls. A cutoff to prevent or minimize the structure, excavate the soil underwater, and then seepage into an excavation can also be formed by dig- tremie in a concrete seal. The concrete tremie seal ging a narrow trench around the area to be excavated must withstand uplift pressures, or pressure relief and backfilling it with an impervious soil. Such a measures must be used. In restricted areas, it may be trench can be constructed in almost any soil, either necessary to use a combination of sheeting and bracing above or below the water table, by keeping the trench with wells or wellpoints installed just inside or outside filled with a bentonite mud slurry and backfilling it of the sheeting. Sheet piling is not very effective in with a suitable impervious soil. Generally, the trench blocking seepage where boulders or other hard ob-is backfilled with a well-graded clayey sand gravel structions may be encountered because of driving out mixed with bentonite slurry. Details regarding design of interlock.
and construction of a slurry cutoff wall are given in e. Freezing. Seepage into a excavation or shaft can paragraphs 4-9g(2) and 5-5b. be prevented by freezing the surrounding soil. How-
- c. Concrete walls. Techniques have been developed ever, freezing is expensive and requires expert design, for constructing concrete cutoff walls by overlapping installation, and operation. If the soil around the exca-cylinders and also as continuous walls excavated and vation is not completely frozen, seepage can cause rap-2-7
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Army Corps of Engineers Figure 2-8. Deep wells with auxiliary vacuum system for dewatering a shaft in stratified materials.
id enlargement of a fault (unfrozen zone) with conse- 2-10. Selection of dewatering system.
quent serious trouble, which is difficult to remedy. a. General. The method most suitable for dewater-ing an excavation depends upon the location, type, 2-9. Summary of groundwater control size, and depth of the excavation; thickness, stratifica-methods. A brief summary of groundwater control tion, and permeability of the foundation soils below methods discussed in this section is given in table 2-1. the water table into which the excavation extends or is 2-8
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 Figure 2-9. Sand drains for dewatering a slope.
underlain; potential damage resulting from failure of (3) Labor requirements.
the dewatering system; and the cost of installation and (4) Duration of required pumping.
operation of the system. The cost of a dewatering The rapid development of slurry cutoff walls has made method or system will depend upon: this method of groundwater control, combined with a (1) Type, size, and pumping requirements of proj- certain amount of pumping, a practical and econom-ect. ical alternative for some projects, especially those (2) Type and availability of power. where pumping costs would otherwise be great.
U.S. Army Corps of Engineers Figure 2-10. Electra-osmotic wellpoint system for stabilizing an excavation slope.
2-9
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Army Corps of Engineers Figure 2-11. Grout curtain or cutoff trench around an excavation.
- b. Factors controlling selection. Where foundations vation surrounded by a cofferdam. Excavations for must be constructed on soils below the groundwater deep shafts, caissons, or tunnels that penetrate strati-level, it will generally be necessary to dewater the ex- fied pervious soil or rock can generally best be dewa-cavation by means of a deep-well or wellpoint system tered with either a deep-well system (with or without rather than trenching and sump pumping. Dewatering an auxiliary vacuum) or a jet-eductor wellpoint system is usually essential to prevent damage to foundation depending on the soil formation and required rate of soils caused by equipment operations and sloughing or pumping, but slurry cutoff walls and freezing should sliding in of the side slopes. Conventional deep-well be evaluated as alternative procedures. Other factors and wellpoint systems designed and installed by com- relating to selection of a dewatering system are inter-panies specializing in this work are generally satisfac- ference of the system with construction operations, tory, and detailed designs need not be prepared by the space available for the system, sequence of construc-engineer. However, where unusual pressure relief or tion operations, durations of dewatering, and cost of dewatering requirements must be achieved, the engi- the installation and its operation. Where groundwater neer should make detailed analyses and specify the de- lowering is expensive and where cofferdams are re-watering system or detailed results to be achieved in quired, caisson construction may be more economical.
the contract documents. Where unusual equipment Caissons are being used more frequently, even for and procedures are required to achieve desired results, small structures.
they should be described in detail in the contract docu- (2) Geologic and soil conditions. The geologic and ments. The user of this manual is referred to soil formations at a site may dictate the type of dewa-paragraphs 6b, 14b, and 2f of Appendix III, TM tering or drainage system. If the soil below the water 5-818-4/AFM 88-5, Chapter 5, for additional discus- table is a deep, more or less homogeneous, free-drain-sions of dewatering requirements and contract speci- ing sand, it can be effectively dewatered with either a fications. Major factors affecting selection of dewater- conventional well or wellpoint system. If, on the other ing and groundwater control systems are discussed in hand, the formation is highly stratified, or the saturat-the following paragraphs. ed soil to be dewatered is underlain by an impervious (1) Type of excavation. Small open excavations, or stratum of clay, shale, or rock, wellpoints or wells on excavations where the depth of water table lowering is relatively close centers may be required. Where soil small, can generally be dewatering most economically and groundwater conditions require only the relief of and safely by means of a conventional wellpoint sys- artesian pressure beneath an excavation, this pressure tem. If the excavation requires that the water table or relief can be accomplished by means of relatively few artesian pressure be lowered more than 20 or 30 feet, a deep wells or jet-eductor wellpoints installed around system of jet-eductor type wellpoints or deep wells and at the top of the excavation.
may be more suitable. Either wellpoints, deep wells, or (a) If an aquifer is thick so that the penetration a combination thereof can be used to dewater an exca- of a system of wellpoints is small, the small ratio of 2-10
TM 88-5, Chap 6/NAVFAC P-418 2-11
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 screen length to aquifer thickness may result in rela- ing required to dewater an excavation may vary from tively little drawdown within the excavation, even 5 to 50,000 gallons per minute or more. Thus, flow to a though the water table is lowered 15 to 20 feet at the drainage system will have an important effect on the line of wellpoints. For deep aquifers, a deep-well sys- design and selection of the wells, pumps, and piping tem will generally be more applicable, or the length of system. Turbine or submersible pumps for pumping the wellpoints should be increased and the wellpoints deep wells are available in sizes from 3 to 14 inches set deep and surrounded with a high-capacity filter. with capacities ranging from 5 to 5000 gallons per On the other hand, if the aquifer is relatively thin or minute at heads up to 500 feet. Wellpoint pumps are stratified wellpoints may be best suited to the situa- available in sizes from 6 to 12 inches with capacities tion. ranging from 500 to 5000 gallons per minute depend-(b) The perviousness and drainability of a soil or ing upon vacuum and discharge heads. Jet-eductor rock may dictate the general type of a dewatering sys- pumps are available that will pump from 3 to 20 gal-tem to be used for a project. A guide for the selection lons per minute for lifts up to 100 feet. Where soil con-of a dewatering system related to the grain size of soils ditions dictate the use of vacuum or electroosmotic is presented in figure 2-12. Some gravels and rock for- wellpoint systems, the rate of pumpage will be very mations may be so permeable that a barrier to flow, small. The rate of pumpage will depend largely on the such as a slurry trench, grout curtain, sheet pile cutoff, distance to the effective source of seepage, amount of or freezing, may be necessary to reduce the quantity of drawdown or pressure relief required, and thickness flow to the dewatering system to reasonable propor- and perviousness of the aquifer through which the tions. Clean, free-draining sands can be effectively de- flow is occurring.
watered by wells or wellpoints. Drainage of sandy silts (6) Intermittent pumping. Pumping labor costs can and silts will usually require the application of addi- occasionally be materially reduced by pumping a dewa-tional vacuum to well or wellpoint dewatering sys- tering system only one or two shifts per day. While tems, or possibly the use of the electroosmotic method this operation is not generally possible, nor advan-of dewatering where soils are silty or clayey. However, tageous, it can be economical where the dewatered where thin sand layers are present, special require- area is large; subsoils below subgrade elevation are ments may be unnecessary. Electroosmosis should nev- deep, pervious, and homogeneous; and the pumping er be used until a test of a conventional system of well- plant is oversize. Where these conditions exist, the points, wells with vacuum, or jet-eductor wellpoints pumping system can be operated to produce an abnor-has been attempted. mally large drawdown during one or two shifts. The (3) Depth of groundwater lowering. The magni- recovery during nonpumping shifts raises the ground-tude of the drawdown required is an important con- water level, but not sufficiently to approach subgrade sideration in selecting a dewatering system. If the elevation. This type of pumping plant operation drawdown required is large, deep wells or jet-eductor should be permitted only where adequate piezometers wellpoints may be the best because of their ability to have been installed and are read frequently.
achieve large drawdowns from the top of an excava- (7) Effect of groundwater lowering on adjacent tion, whereas many stages of wellpoints would be re- structures and wells. Lowering the groundwater table quired to accomplish the same drawdown. Deep wells increases the load on foundation soils below the ori-can be used for a wide range of flows by selecting ginal groundwater table. As most soils consolidate pumps of appropriate size, but jet-eductor wellpoints upon application of additional load, structures located are not as flexible. Since jet-eductor pumps are rela- within the radius of influence of a dewatering system tively inefficient, they are most applicable where well may settle. The possibility of such settlement should flows are small as in silty to fine sand formations. be investigated before a dewatering system is de-(4) Reliability requirements. The reliability of signed. Establishing reference hubs on adjacent struc-groundwater control required for a project will have a tures prior to the start of dewatering operations will significant bearing on the design of the dewatering permit measuring any settlement that occurs during pumps, power supply, and standby power and equip- dewatering, and provides a warning of possible dis-ment. If the dewatering problem is one involving the tress or failure of a structure that might be affected.
relief of artesian pressure to prevent a blowup of the Recharge of the groundwater, as illustrated in figure.
bottom of an excavation, the rate of water table re- 2-13, may be necessary to reduce or eliminate distress bound, in event of failure of the system, may be ex- to adjacent structures, or it may be necessary to use tremely rapid. Such a situation may influence the type positive cutoffs to avoid lowering the groundwater of pressure relief system selected and require inclusion level outside of an excavation. Positive cutoffs include of standby equipment with automatic power transfer soil freezing and slurry cutoff techniques. Observa-and starting equipment. tions should be made of the water level in nearby wells (5) Required rate of pumping. The rate of pump before and during dewatering to determine any effect 2-12
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 2-13
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Army Corps of Engineers Figure 2-13. Recharge of groundwater toprevent settlement of a building as a result of dewatering operations of dewatering. This information will provide a basis design elevation without lowering the groundwater for evaluating any claims that may be made. level; use a combination of concrete cutoff walls con-(8) Dewatering versus cutoffs and other proce- structed in slurry-supported trenches, and a tremied dures. While dewatering is generally the most ex- concrete foundation slab, in which case the cutoff peditious and economical procedure for controlling walls may serve also as part of the completed struc-water, it is sometimes possible to excavate more eco- ture; use large rotary drilling machines for excavating nomically in the wet inside of a cofferdam or caisson purposes, without lowering the groundwater level; or and then seal the bottom of the excavation with a use freezing techniques. Cofferdams, caissons, and cut-tremie seal, or use a combination of slurry wall or off walls may have difficulty penetrating formations other type of cutoff and dewatering. Where subsurface containing numerous boulders. Foundation designs re-construction extends to a considerable depth or where quiring compressed air will rarely be needed, although high uplift pressures or large flows are anticipated, it compressed air may be economical or necessary for may occasionally be advantageous to: substitute a some tunnel construction work.
caisson for a conventional foundation and sink it to the 2-14
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 CHAPTER 3 GEOLOGIC, SOIL, AND GROUNDWATER INVESTIGATIONS 3-1. General. Before selecting or designing a sys- 3-2. Geologic and soil conditions. An un-tem for dewatering an excavation, it is necessary to derstanding of the geology of the area is necessary to consider or investigate subsurface soils, groundwater plan any investigation of subsurface soil conditions.
conditions, power availability, and other factors as Information obtained from the geologic and soil in-listed in table 3-1. The extent and detail of these in- vestigations as outlined in TM 5-818-1/AFM 88-3, vestigations will depend on the effect groundwater Chapter 7 or NAVFAC DM7.1, should be used in and hydrostatic pressure will have on the construction evaluating a dewatering or groundwater control prob-of the project and the complexity of the dewatering lem. Depending on the completeness of information problem. available, it may be possible to postulate the general Table 3-1. Preliminary Investigations Item Investigate Reference Geologic and soil Type, stratification, and Para 3-2; TM 5-818-1/
conditions thickness of soil involved AFM 88-3, Chapter 7 in excavation and NAVFAC DM7.1 dewatering Criticality Reliability of power system, damage to excavation or foundation in event of f a i l u r e , rate of rebound, etc.
Groundwater or Groundwater table or hydro- Para 2-3 and 3-3 piezometric static pressure in area and pressure its source. Variation with characteristics river stage, season of year, e t c . Type of seepage (arte-sian, gravity, combined).
Chemical characteristics and temperature of groundwater .
Permeability Determine permeability from Para 3-4; Appendix C visual, field, or labora-tory tests, preferably by field tests.
Power Availability, reliability, Para 3-5 and capacity of power at site.
Degree of possible Rainfall in area. Runoff Para 3-6 flooding characteristics. High-water levels in nearby bodies of water.
3-1
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 characteristics and stratification of the soil and rock (a) Completely penetrate and sample all formations in the area. With this information and the aquifers that may have a bearing on dewatering an ex-size of and depth of the excavation to be dewatered, cavation and controlling artesian pressures.
the remainder of the geologic and soil investigations (b) Identify (and sample) all soils or rocks that can be planned. Seismic or resistivity surveys (as well would affect or be affected by seepage or hydrostatic as logged core and soil borings) may be useful in deline- pressure.
ating the thickness and boundaries of major geologic (c) Delineate the soil stratification.
and soil formations and will often show irregularities (d) Reveal any significant variation in soil and in the geologic profile that might otherwise go unde- rock conditions that would have a bearing on seepage tected (fig. 3-1). flow, location and depth of wells, or depth of cutoff.
- a. Borings. Continuous wash or auger boring samples are not con-(1) A thorough knowledge of the extent, thick- sidered satisfactory for dewatering exploration as the ness, stratification, and seepage characteristics of the fines tend to be washed out, thereby changing the subsurface soil or rock adjacent to and beneath an ex- character of the soil.
cavation is required to analyze and design a dewater- b. Rock coring. Rock samples, to be meaningful for ing system. These factors are generally determined groundwater studies, should be intact samples ob-during the normal field exploration that is required for tained by core drilling. Although identification of most structures. Samples of the soil or rock formation rocks can be made from drill cuttings, the determina-obtained from these borings should be suitable for tion of characteristics of rock formations, such as fre-classifying and testing for grain size and permeability, quency, orientation, and width of joints or fractures, if the complexity of the project warrants. All of the in- that affect groundwater flow requires core samples.
formation gathered in the investigation should be pre- The percent of core recovery and any voids or loss of sented on soil or geologic profiles of the site. For large, drill water encountered while core drilling should be complex dewatering or drainage projects, it may be de- recorded. The approximate permeability of rock strata sirable to construct a three-dimensional model of col- can be measured by making pressure or pumping tests ored pegs or transparent plastic to depict the different of the various strata encountered. Without pressure or geologic or soil formations at the site. pumping tests, important details of a rock formation (2) The depth and spacing of borings (and sam- can remain undetected, even with extensive boring ples) depend on the character of the materials and on and sampling. For instance, open channels or joints in the type and configuration of the formations or depos- a rock formation can have a significant influence on its as discussed in TM 5-818-1/AFM 88-3, Chapter 7. the permeability of the formation, yet core samples Care must be taken that the borings accomplish the may not clearly indicate these features where the core following: recovery is less than 100 percent.
U.S. Army Corps of Engineers Figure 3-1. Geologic profile developed from geophysical explorations.
3-2
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418
- c. Soil testing. samples of sand that have been segregated or con-(1) All soil and rock samples should be carefully taminated with drilling mud during sampling opera-classified, noting particularly those characteristics tions do not give reliable results. In addition, the that have a bearing on the perviousness and stratifica- permeability of remolded samples of sand is usually tion of the formation. Soil samples should be classified considerably less than the horizontal permeability kh in accordance with the Unified Soil Classification Sys- of a formation, which is generally the more significant tem described in MIL-STD-619B. Particular atten- k factor pertaining to seepage flow to a drainage sys-tion should be given to the existence and amount of tem.
fines (material passing the No. 200 sieve) in sand sam- (3) Where a nonequilibrium type of pumping test ples, as such have a pronounced effect on the perme- (described in app C) is to be conducted, it is necessary ability of the sand. Sieve analyses should be made on to estimate the specific yield Sy of the formation, representative samples of the aquifer sands to deter- which is the volume of water that is free to drain out mine their gradation and effective grain size D10. The of a material under natural conditions, in percentage D10 size may be used to estimate the coefficient of of total volume. It can be determined in the laboratory permeabililty k . The gradation is required to design by:
filters for wells, wellpoints, or permanent drainage (a) Saturating the sample and allowing it to systems to be installed in the formation. Correlations drain. Care must be taken to assure that capillary between k and D10 are presented in paragraph 3-4. stresses on the surface of the sample do not cause an (2) Laboratory tests depicted in figure 3-2 can be incorrect conclusion regarding the drainage.
used to determine the approximate coefficient of (b) Estimating Sy from the soil type and D10 size permeability of a soil or rock sample; however, perme- of the soil and empirical correlations based on field abilities obtained from such tests may have little rela- and laboratory tests. The specific yield can be com-tion to field permeability even though conducted puted from a drainage test as follows:
under controlled conditions. When samples of sand are 100V y distributed and repacked, the porosity and orientation Sy = (3-1)
V of the grains are significantly changed, with resulting where modification of the permeability. Also, any air en- V y = volume of water drained from sample trapped in the sand sample during testing will signifi- V = gross volume of sample cantly reduce its permeability. Laboratory tests on The specific yield can be estimated from the soil type (From Ground Water Hydrology by D. K. Todd, 1959, Wiley & Sons, Inc. Used with permission of Wiley & Sons, Inc.)
Figure 3-2. Permeameters: (a) constant head and(b) falling head.
3-3
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (or D10) and the relation given in figure 3-3 or table crustations in the wells or filters and, with time, cause 3-2. clogging and -reduced efficiency of the dewatering or drainage system. Indicators of corrosive and incrust-3-3. Groundwater characteristics. ing waters are given in table 3-3. (Standard methods
- a. An investigation of groundwater at a site should for determining the chemical compositions of ground-include a study of the source of groundwater that water are available from the American Public Health would flow to the dewatering or drainage system (para Association, Washington, DC 2-2) and determination of the elevation of the water d. Changes in the temperature of the groundwater table and its variation with changes in river or tide will result in minor variations of the quantity of water stages, seasonal effects, and pumping from nearby wa- flowing to a dewatering system. The change in viscosi-ter wells. Groundwater and artesian pressure levels at ty associated with temperature changes will result in a a construction site are best determined from piezom- change in flow of about 1.5 percent for each 1° eters installed in the stratum that may require dewa- Fahrenheit of temperature change in the water. Only tering. Piezometers in pervious soils may be commer- large variations in temperature need be considered in cial wellpoints, installed with or without a filter (para design because the accuracy of determining other 4-6c) as the gradation of foundation material requires. parameters does not warrant excessive refinement.
Piezometers in fine-grained soils with a low perme-ability, such as silt, generally consist of porous plastic 3-4. Permeability of pervious strata. The or ceramic tips installed within a filter and attached to rate at which water can be pumped from a dewatering a relatively small diameter riser pipe. system is directly proportional to the coefficient of permeability of the formation being dewatered; thus,
- b. The groundwater regime should be observed for this parameter should be determined reasonably accu-an extended period of time to establish variations in rately prior to the design of any drainage system.
level likely to occur during the construction or opera- Methods that can be used to estimate or determine the tion of a project. General information regarding the permeability of a pervious aquifer are presented in the groundwater table and river or tide stages in the area following paragraphs.
is often available from public agencies and may serve as a basis of establishing general water levels. Specific a. Visual classification. The simplest approximate conditions at a site can then be predicted by correlat- method for estimating the permeability of sand is by ing the long-term recorded observations in the area visual examination and classification, and comparison with more detailed short-term observations at the site. with sands of known permeability. An approximation
- c. The chemical composition of the groundwater is of the permeability of clean sands can be obtained of concern, because some groundwaters are highly cor- from table 3-4.
rosive to metal screens, pipes, and pumps, or may con- b. Empirical relation between D10 and k. The per-tain dissolved metals or carbonates that will form in- meability of a clean sand can be estimated from em-(From Ground Water Hydrology by D. K. Todd, 1959, Wiley & Sons, Inc. Used with permission of Wiley & Sons, Inc.)
Figure 3-3. Specific yield of water-bearing sands versus D10, South Coastal Basin, California.
3-4
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 Table 3-2. Specific Yield of Water-Bearing Deposits in Sacramento Valley, California Specific Yield Material percent Gravel 25 Sand, including sand and gravel, and gravel and sand 20 Fine sand, hard sand, tight sand, sandstone, and related deposits 10 Clay and gravel, gravel and clay, cemented gravel, and related deposits 5 Clay, silt, sandy clay, lava rock, and related fine-grained deposits 3 (From Ground Water Hydrology by D. K. Todd, 1959, Wiley & Sons, Inc. Used with permission of Wiley & Sons, Inc.)
Table 3-3. Indicators of Corrosive and Incrusting Waters Indicators of Indicators of Corrosive Water Incrusting Water
- 1. A pH less than 7 1. A pH greater than 7
- 3. Hydrogen sulfide (H 2 S) in excess of 3. Total manganese (Mn) in excess of 1 ppm in con-1 ppm, detected by a rotten egg junction with a high pH odor and the presence of oxygen
- 4. Total dissolved solids in excess of 4. Total carbonate hardness 1,000 ppm indicates an ability to in excess of 300 ppm conduct electric current great enough to cause serious electro-lytic corrosion
- 5. Carbon dioxide (CO 2 ) in excess of 50 ppm
- 6. Chlorides (Cl) in excess of 500 ppm (Courtesy of UOP Johnson Division) 3-5
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 Table 3-4. Approximate Coefficient of Permeability for Various Sands Coefficient of Permeability k Type of Sand (Unified -4
-4 Soil Classification System) x 10 cm/sec x 10 ft/min Sandy silt 5-20 10-40 Silty sand 20-50 40-100 Very fine sand 50-200 100-400 Fine sand 200-500 400-1,000 Fine to medium sand 500-1,000 l,000-2,000 Medium sand 1,000-1,500 2,000-3,000 Medium to coarse sand 1,500-2,000 3,000-4,000 Coarse sand and gravel 2,000-5,000 4,000-10,000 U. S. Army Corps of Engineers pirical relations between D10 and k (fig. 3-4), which filter surrounding the well screen, and the rate of in-were developed from laboratory and field pumping flow or fall in water level must be accurately meas-tests for sands in the Mississippi and Arkansas River ured. Disturbance of the soil adjacent to a borehole or valleys. An investigation of the permeability of filter filter, leakage up the borehole around the casing, clog-sands revealed that the permeability of clean, rela- ging or removal of the fine-grained particles of the tively uniform, remolded sand could be estimated from aquifer, or the accumulation of gas bubbles in or the empirical relation: around the well screen can make the test completely k = C (D10)2 (3-2) unreliable. Data from such tests must be evaluated where k = coefficient of permeability, centimetres per second C 100 (may vary from 40 to 150)
D 10 = effective grain size, centimetres Empirical relations between D10 and k are only approx-imate and should be used with reservation until a cor-relation based on local experience is available.
- c. Field pumping tests. Field pumping tests are the most reliable procedure for determining the in situ permeability of a water-bearing formation. For large dewatering jobs, a pumping test on a well that fully penetrates the sand stratum to be dewatered is war-ranted; such tests should be made during the design phase so that results can be used for design purposes and will be available for bidders. However, for small dewatering jobs, it may be more economical to select a more conservative value of k based on empirical rela-tions than to make a field pumping test. Pumping tests are discussed in detail in appendix C.
- d. Simple field tests in wells or piezometers. The permeability of a water-bearing formation can be esti-mated from constant or falling head tests made in wells or piezometers in a manner similar to laboratory permeameter tests. Figure 3-5 presents formulas for determining the permeability using various types and installations of well screens. As these tests are sensi-tive to details of the installation and execution of the Figure 3-4. D10 versus in situ coefficient of horizontal permeability-test, exact dimensions of the well screen, casing, and Mississippi River valley and Arkansas River valley.
3-6
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 ASSUMPTIONS SOIL AT INTAKE, INFINITE DEPTH AND DIRECTIONAL ISOTROPY (k, AND k h CONSTANT) - NO DISTURBANCE, SEGREGATION, SWELLING, OR CONSOLIDATION OF SOIL - NO SEDIMENTATION OR L E A K A G E - N O A I R O R G A S I N S O I L , W E L L P O I N T , O R P I P E - HYDRAULIC LOSSES IN PIPES, W E L L -
POINT, OR FILTER NEGLIGIBLE.
U.S. Army Corps of Engineers Figure 3-5. Formulas for determiningpermeability from field failing head tests.
3-7
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 carefully before being used in the design of a major de- lications of the U.S. Weather Bureau or other refer-watering or drainage system. ence data. Maps showing amounts of rainfall that can be expected once every 2, 5, and 10 years in 10-, 30-,
3-5. Power. The availability, reliability, and and 60-minute duration of rainfall are shown in figure capacity of power at a site should be investigated prior 3-6. The coefficient of runoff c within the excavation to selecting or designing the pumping units for a dewa- will depend on the character of soils present or the tering system. Types of power used for dewatering sys- treatment, if any, of the slopes. Except for excavations tems include electric, natural gas, butane, diesel, and in clean sands, the coefficient of runoff c is generally gasoline engines, Electric motors and diesel engines from 0.8 to 1.0. The rate of runoff can be determined are most commonly used to power dewatering equip- as follows:
ment.
Q = ciA (3-3) 3-6. Surface water. Investigations for the con- where trol of surface water at a site should include a study of precipitation data for the locality of the project and de- Q= rate of runoff, cubic feet per second termination of runoff conditions that will exist within c= coefficient of runoff the excavation. Precipitation data for various localities i= intensity of rainfall, inches per hour and the frequency of occurrence are available in pub A= drainage area, acres (U. S. Department of Agriculture Miscellaneous Publication No. 204)
Figure 3-6. Inches of rainfall during 10- and 30-minute and 1-hour periods.
3-8
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 CHAPTER 4 DESIGN OF DEWATERING, PRESSURE RELIEF, AND GROUNDWATER CONTROL SYSTEMS 4-1. Analysis of groundwater flow. design of dewatering systems has been discussed in
- a. Design of a dewatering and pressure relief or chapter 3. Mathematical, graphical, and electroanalo-groundwater control system first requires determina- gous methods of analyzing seepage flow through gen-tion of the type of groundwater flow (artesian, gravity,, eralized soil conditions and boundaries to various or combined) to be expected and of the type of system types of dewatering or pressure relief systems are pre-that will be required. Also, a complete picture of the sented in paragraphs 4-2, 4-3, and 4-4.
groundwater and the subsurface condition is neces- e. Other factors that have a bearing on the actual sary. Then the number, size, spacing, and penetration design of dewatering, permanent drainage, and sur-of wellpoints or wells and the rate at which the water face-water control systems are considered in this chap-must be removed to achieve the required groundwater ter.
lowering or pressure relief must be determined. f. The formulas and flow net procedures presented
- b. In the analysis of any dewatering system, the in paragraphs 4-2, 4-3, and 4-4 and figures 4-1 source of seepage must be determined and the bounda- through 4-23 are for a steady state of groundwater ries and seepage flow characteristics of geologic and flow. During initial stages of dewatering an excava-soil formations at and adjacent to the site must be gen- tion, water is removed from storage and the rate of eralized into a form that can be analyzed. In some flow is larger than required to maintain the specified cases, the dewatering system and soil and groundwa- drawdown. Therefore, initial pumping rates will prob-ter flow conditions can be generalized into rather sim- ably be about 30 percent larger than computed values.
ple configurations. For example, the source of seepage g. Examples of design for dewatering and pressure can be reduced to a line or circle; the aquifer to a homo- relief systems are given in appendix D.
geneous, isotropic formation of uniform thickness; and the dewatering system to one or two parallel lines or 4-2. Mathematical and model analyses.
circle of wells or wellpoints. Analysis of these condi-tions can generally be made by means of mathematical a. General.
formulas for flow of groundwater. Complicated con- (1) Design. Design of a dewatering system re-quires the determination of the number, size, spacing, figurations of wells, sources of seepage, and soil forma-and penetration of wells or wellpoints and the rate at tions can, in most cases, be solved or at least approxi-which water must be removed from the pervious strata mated by means of flow nets, electrical analogy mod-to achieve the required groundwater lowering or pres-els, mathematical formulas, numerical techniques, or a sure relief. The size and capacity of pumps and collec-combination of these methods.
tors also depend on the required discharge and draw-
- c. Any analysis, either mathematical, flow net, or down. The fundamental relations between well and electrical analogy, is not better than the validity of the wellpoint discharge and corresponding drawdown are formation boundaries and characteristics used in the presented in paragraphs 4-2, 4-3, and 4-4. The equa-analysis. The solution obtained, regardless of the rigor tions presented assume that the flow is laminar, the or precision of the analysis, will be representative of pervious stratum is homogeneous and isotropic, the actual behavior only if the problem situation and water draining into the system is pumped out at a con-boundary conditions are adequately represented. An stant rate, and flow conditions have stabilized. Proce-approximate solution to the right problem is far more dures for transferring an anisotropic aquifer, with re-desirable than a precise solution to the wrong problem. spect to permeability, to an isotropic section are pre-The importance of formulating correct groundwater sented in appendix E.
flow and boundary conditions, as presented in chapter (2) Equations for flow and drawdown to drainage 3, cannot be emphasized too strongly. slots and wells. The equations referenced in para-
- d. Methods for dewatering and pressure relief and graphs 4-2, 4-3, and 4-4 are in two groups: flow and their suitability for various types of excavations and drawdown to slots (b below and fig. 4-1 through 4-9) soil conditions were described in chapter 2. The inves- and flow and drawdown to wells (c below and fig. 4-10 tigation of factors relating to groundwater flow and to through 4-22). Equations for slots are applicable to 4-1
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 COMBINED ARTESIAN-GRAVITY FLOW (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company.
Used with permission of McGraw- Hill Book Company.)
Figure 4-1. Flow and head for fully penetrating line slot; single-line source; artesian, gravity, and combined flows.
flow to trenches, French drains, and similar drainage for slots and wells do not consider the effects of hy-systems. They may also be used where the drainage draulic head losses Hw in wells or wellpoints; proce-system consists of closely spaced wells or wellpoints. dures for accounting for these effects are presented Assuming a well system equivalent to a slot usually separately.
simplifies the analysis; however, corrections must be (3) Radius of influence R. Equations for flow to made to consider that the drainage system consists of drainage systems from a circular seepage source are wells or wellpoints rather than the more efficient slot. based on the assumption that the system is centered These corrections are given with the well formulas dis- on an island of radius R. Generally, R is the radius of cussed in c below. When the well system cannot be influence that is defined as the radius of a circle be-simulated with a slot, well equations must be used. yond which pumping of a dewatering system has no The figures in which equations for flow to slots and significant effect on the original groundwater level or wells appear are indexed in table 4-1. The equations piezometric surface. The value of R can be estimated 4-2
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962. McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-2. Height of free discharge surface hs; gravity flow.
4-3
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962. McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-3. Flow and head for partially penetrating line slot; single-line source; artesian, gravity, and combined flows.
4-4
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 FULLY PENETRATING SLOT THE FLOW TO A FULLY PENETRATING SLOT FROM TWO LINE SOURCES, BOTH OF INFINITE LENGTH (AND PARALLEL), IS THE SUM OF THE FLOW FROM EACH SOURCE, WITH REGARD TO THE APPROPRIATE FLOW BOUNDARY CONDITIONS, AS DETERMINED FROM THE FLOW EQUATIONS IN FIG. 4-1. LIKEWISE. THE DRAWDOWN FROM EACH SOURCE CAN BE COMPUTED FROM THE DRAWDOWN EQUATIONS IN FIG. 4-1 AS IF ONLY ONE SOURCE EXISTED.
PARTIALLY PENETRATING SLOT ARTESIAN FLOW (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-4. Flow and head for fully and partially penetrating line slot; two-line source; artesian and gravity flows.
4-5
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 A F R E Q U E N T L Y E N C O U N T E R E D DEWATERING S Y S T E M I S O N E W I T H T W O L I N E S O F P A R T I A L L Y PENETRATING WELLPOINTS ALONG EACH SIDE OF A LONG EXCAVATION, WHERE THE FLOW CAN BE ASSUMED TO ORIGINATE FROM TWO EQUIDISTANT LINE SOURCES.
(Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-5. Flow and head (midway) for twopartially penetrating slots; two-line source; artesian and gravity flows, 4-6
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Army Corps of Engineers Figure 4-6. Flow and head for fully and partially penetrating circular slots; circular source; artesian flow.
from the equation and plots in figure 4-23. Where be selected conservatively from pumping test data or, there is little or no recharge to an aquifer, the radius of if necessary, from figure 4-23.
influence will become greater with pumping time and (4) Wetted screen. There should always be suffi-with increased drawdown in the area being dewatered. cient well and screen length below the required draw-Generally, R is greater for coarse, very pervious sands down in a well in the formation being dewatered so that than for finer soils. If the value of R is large relative to the design or required pumping rate does not produce the size of the excavation, a reasonably good approxi- a gradient at the interface of the formation and the mation of R will serve adequately for design because well filter (or screen) or at the screen and filter that flow and drawdown for such a condition are not espe- starts to cause the flow to become turbulent. There-cially sensitive to the actual value of R. As it is usually fore, the design of a dewatering system should always impossible to determine R accurately, the value should be checked to see that the well or wellpoints have ade-4-7
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Army Corps of Engineers Figure 4-7. Head at center of fully and partially penetrating circular slots; circular source; artesian flow.
4-8
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Army Corps of Engineers Figure 4-8. Flow and drawdown at slot for fully and partially penetrating rectangular slots; circular source; artesian flow.
quate wetted screen length hws or submergence to ures 4-1 through 4-22 do not consider hydraulic head pass the maximum computed flow. The limiting flow losses that occur in the filter, screen, collector pipes, qc into a filter or well screen is approximately equal to etc. These losses cannot be neglected, however, and 7.48 gallons per minute must be accounted for separately. The hydraulic head qc = x per foot of filter (4-1) loss through a filter and screen will depend upon the 1.07 diameter of the screen, slot width, and opening per or screen where foot of screen, permeability and thickness of the filter; rW = radius of filter or screen any clogging of the filter or screen by incrustation, k = coefficient of permeability of filter or aquifer drilling fluid, or bacteria; migration of soil or sand par-sand, feet per minute ticles into the filter; and rate of flow per foot of screen.
Graphs for estimating hydraulic head losses in pipes, (5) Hydraulic head loss Hw. The equations in fig- wells, and screens are shown in figures 4-24 and 4-25.
4-9
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Corps of Engineers Figure 4-9. Head within a partially penetrating rectangular slot; circular source; artesian flow, 4-10
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from "Foundation Engineering," G. A. Leonards, ed., 1962, McGraw-Hill Book Company Used with permission of McGraw-Hill Book Company.)
Figure 4-10. Flow and drawdown for fully and partially penetrating single wells; circular source; artesian flow.
4-11
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from "Foundation Engineering," G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-11. Flow and drawdown for fully and partially penetrating single wells; circular source; gravity flow.
4-12
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from "Foundation Engineering," G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-12. Flow and drawdown for fully penetrating single well; circular source; combined artesian and gravity flows.
4-13
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from "Foundation Engineering," G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-13. Flow and drawdown for fully penetrating multiple wells; circular source; artesian and gravity flows.
4-14
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-14. Drawdown factors for fully penetrating circular, rectangular, and two-line well arrays; circular source; artesian and gravity flows.
4-15
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Army Corps of Engineers Figure 4-15. Flow and drawdown for fully penetrating circular well arrays; circular source; artesian flow.
(6) Well or screen penetration W/D. thickness of the aquifer, distance to the effective (a) Most of the equations and graphs presented source of seepage, well or wellpoint radius, stratifica-in this manual for flow and drawdown to slots or well tion, required wetted screen length, type and size of systems were basically derived for fully penetrating excavation, and whether or not the excavation pene-drainage slots or wells. Equations and graphs for par- trates alternating pervious and impervious strata or tially penetrating slots or wells are generally based on the bottom is underlain at a shallow depth by a less those for fully penetrating drainage systems modified pervious stratum of soil or rock. Where a sizeable open by model studies and, in some instances, mathematical excavation or tunnel is underlain by a fairly deep derivations. The amount or percent of screen penetra- stratum of sand and wells are spaced rather widely, tion required for effective pressure reduction or inter- the well screens should penetrate at least 25 percent of ception of seepage depends upon many factors, such as the thickness of the aquifer to be dewatered below the 4-16
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 SEE FIG. 4-15. a, b, AND c FOR EXPLANATION OF TERMS NOT DEFINED IN THIS FIGURE.
D R A W D O W N . H - h e, PRODUCED BY PUMPING A FLOW OF Q T FROM AN EQUIVALENT SLOT, IS COMPUTED FROM EQ 1 (FIG. 4-6) FOR CIRCULAR SLOT AND EQ 1 (FIG. 4-8) FOR RECTANGULAR SLOT.
HEAD LOSS DUE TO CONVERGING FLOW AT WELL U.S. Army Corps of Engineers Figure 4-16. Flow and drawdown for partially penetrating circular and rectangular well arrays; circular source; artesian flow.
bottom of the excavation and more preferably 50 to able is limited, the drainage trench or well screen 100 percent. Where the aquifer(s) to be dewatered is should penetrate to the top of the underlying less per-stratified, the drainage slots or well screens should vious stratum. The hydraulic head loss through vari-fully penetrate all the strata to be dewatered. If the ous sizes and types of header or discharge pipe, and for bottom of an excavation in a pervious formation is certain well screens and (clean) filters, as determined underlain at a shallow depth by an impervious forma- from laboratory and field tests, are given in figures tion and the amount of wetted screen length avail- 4-24 and 4-25.
4-17
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 E Q U A T I O N S F O R F L O W A N D DRAWDOWN F O R A F U L L Y P E N E T R A T I N G W E L L W I T H A L I N E S O U R C E O F INFINITE LENGTH WERE DEVELOPED UTILIZING THE METHOD OF IMAGE WELLS. THE IMAGE WELL IS CONSTRUCTED AS SHOWN IN (a) BELOW.
IN THE EQUATIONS ABOVE, THE DISTANCE TO THE LINE SOURCE MUST BE COMPARED TO THE CIRCULAR RADIUS OF INFLUENCE, R, FOR THE WELL. IF 2L IS GREATER THAN R, THE WELL WILL PERFORM AS IF SUPPLIED BY A CIRCULAR SOURCE OF SEEPAGE, AND SOLUTIONS FOR A LINE SOURCE OF SEEPAGE ARE NOT APPLICABLE.
SEE FIG. 4-23 FOR DETERMINING THE VALUE OF R.
S E E F I G . 4 - 2 4 F O R D E T E R M I N I N G T H E V A L U E O F H w.
(Modified from Foundation Engineering, G. A, Leonards, ed., 1962. McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-17. Flow and drawdown for fully penetrating single well; line source; artesian and gravity flows.
4-18
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-18. Flow and drawdown for fully penetrating multiple wells; line source; artesian and gravity flows.
4-19
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-19. Drawdown factors for fully penetrating circular, line, two-line, and rectangular well arrays; line source; artesian and gravity flows.
4-20
TM 5-818-5/AFM 88-5, Chap 6/NAVFACP-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-20. Flow and drawdown for fully penetrating infinite line of wells; line source; artesian flow.
4-21
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 S E E D R A W I N G S I N F I G . 4 - 6 A N D F I G U R E S ( a ) A N D ( b ) B E L O W F O R D E F IN I T I O N S O F T E R M S IN EQUATIONS.
DRAWDOWN, H - h e, P R O D U C E D B Y P U M P I N G Qw FROM AN EQUIVALENT CONTINUOUS SLOT IS COMPUTED FROM EQ 1 (FIG. 4-3).
HEAD LOSS DUE TO CONVERGING FLOW AT WELL (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-21. Flow and drawdown for fully and partially penetrating infinite line of wells; line source; artesian flow.
4-22
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-22. Flow and drawdown for fully penetrating infinite line of wells; line source; gravity flow.
4-23
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-23. Approximate radius of influence R.
(b) Head losses in the screened section of a well (1) Line drainage slots. Equations presented in Hs are calculated from figure 4-24b. This head loss is figures 4-1 through 4-5 can be used to compute flow based on equal inflow per unit of screen surface and and head produced by pumping either a single or a turbulent flow inside the well and is equivalent to the double continuous slot of infinite length. These equa-entire well flow passing through one-half the screen tions assume that the source of seepage and the drain-length. Other head losses can be determined directly age slot are infinite in length and parallel and that from figure 4-24. Hydraulic head loss within a well- seepage enters the pervious stratum from a vertical point system can be estimated from figure 4-25. As line source. In actuality, the slot will be of finite stated in a(4) above, flow into a well can be impeded by length, the flow at the ends of the slot for a distance of the lack of wetted screen length, in addition to hy- about L/2 (where L equals distance between slot and draulic head losses in the filter or through the screens source) will be greater, and the drawdown will be less and/or chemical or mechanical clogging of the aquifer than for the central portion of the slot. Flow to the and filter. ends of a fully penetrating slot can be estimated, if necessary, from flow-net analyses subsequently pre-
- b. Flow to a drainage slot. sented.
4-24
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 Table 4-1. Index to Figures for Flow, Head, or drawdown Equations for Given Corrections Assumed Source Type of Penetration Figure Index Drainage System of Seepage Flow Flow to a slot Line Line slot A, G, C F 4-1, 4-2 Line Line slot A, G, C P 4-2, 4-3 Two-line Line slot A, G P, F 4-4 Two-line Two-line slots A, G P 4-5 Circular Circular slots A P, F 4-6, 4-7 Circular Rectangular slots A P, F 4-8, 4-9 Flow to wells Circular Single well A P, F 4-10 Circular Single well G P, F 4-11 Circular Single well C F 4-12 Circular Multiple wells A, G F 4-13 Circular Circular, rec-tangular, and two-line arrays A, G F 4-14 Circular Circular array A F 4-15 Circular Circular and rectangular array A P 4-16 Single line Single well A, G F 4-17 Single line Multiple wells A, G F 4-18 Single line Circular, line, two-line, and rectangular arrays A, G F 4-19 Single line Infinite line A F 4-20 Single line Infinite line A P, F 4-21 Single line Infinite line G F 4-22 Other Approximate radius of influence 4-23 Hydraulic head loss in a well 4-24 Hydraulic head loss in various wellpoints 4-25 Equivalent length of straight pipe for various fittings 4-26 Shape factors for wells of various penetrations centered inside a circular source 4-27 Flow and drawdown for slots from flow-net analyses 4-28 Flow and drawdown for wells from flow-net analyses 4-29 Diagrammatic layout of electrical analogy model 4-30 Note: A = artesian flow; G = gravity flow; C = combined artesian-gravity flow; F = fully penetrating; P = partially penetrating.
U. S. Army Corps of Engineers 4-25
TM 88-5, Chap 6/NAVFAC P-418 4-26
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 4-27
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (2) Circular and rectangular slots. Equations for will not correspond exactly to that determined for the flow and head or drawdown produced by circular and slot due to convergence of flow to the wells. The piezo-rectangular slots supplied by a circular seepage source metric head in the vicinity of the well is a function of are given in figures 4-6 through 4-9. Equations for well flow Qw; well spacing a; well penetration W; effec-flow from a circular seepage source assume that the tive well radius rw ; aquifer thickness D, or gravity head slot is located in the center of an island of radius R. H; and aquifer permeability k. The equations given in For many dewatering projects, R is the radius of influ- figures 4-15 and 4-16 consider these variables.
ence rather than the radius of an island, and proce- (2) Flow to wells from a line source.
dures for determining the value of R are discussed in (a) Equations given in figures 4-17 through a(3) above. Dewatering systems of relatively short 4-19 for flow and drawdown produced by pumping a length are considered to have a circular source where single well or group of fully penetrating wells supplied they are far removed from a line source such as a river from an infinite line source were developed using the or shoreline. method of image wells. The image well (a recharge (3) Use of slots for designing well systems. Wells well) is located as the mirror image of the real well can be substituted for a slot; and the flow Qw, draw- with respect to the line source and supplies the per-down at the well (H-hw) neglecting hydraulic head vious stratum with the same quantity of water as that losses at and in the well, and head midway between being pumped from the real well.
(b) The equations given in figures 4-18 and from the equations given in figures 4-20, 4-21, and 4-19 for multiple-well systems supplied by a line 4-22 for a (single) line source for artesian and gravity source are based on the fact that the drawdown at any flow for both fully and partially penetrating wells point is the summation of drawdowns produced at that where the well spacing a is substituted for the length point by each well in the system. Consequently, the of slot x. drawdown at a point is the sum of the drawdowns pro-(4) Partially penetrating slots. The equations for duced by the real wells and the negative drawdowns gravity flow topartially penetrating slots are only con- produced by the image or recharge wells.
sidered valid for relatively high-percent penetrations. (c) Equations are given in figures 4-20 through
- c. Flow to wells. 4-22 for flow and drawdown produced by pumping an (1) Flow to wells from a circular source. infinite line at wells supplied by a (single) line source.
The equations are based on the equivalent slot assump-(a) Equations for flow and drawdown produced tion. Where twice the distance to a single line source by a single well supplied by a circular source are given or 2L is greater than the radius of influence R, the in figures 4-10 through 4-12. It is apparent from fig-ure 4-11 that considerable computation is required to value of R as determined from a pumping test or from figure 4-23 should be used in lieu of L unless the exca-determine the height of the phreatic surface and re-sulting drawdown in the immediate vicinity of a grav- vation is quite large or the tunnel is long, in which case ity well (r/h less than 0.3). The drawdown in this zone equations for a line source or a flow-net analysis usually is not of special interest in dewatering systems should be used.
and seldom needs to be computed. However, it is al- (d) Equations for computing the head midway ways necessary to compute the water level in the well between wells above that in the wells Ah, are not for the selection and design of the pumping equip- given in this manual for two line sources adjacent to a ment. single line of wells. However, such can be readily de-(b) The general equations for flow and draw- termined from (plan) flow-net analyses.
down produced by pumping a group of wells supplied (3) Limitations on flow to a partially penetrating well. Theoretical boundaries for a partially penetrat-by a circular source are given in figure 4-13. These equations are based on the fact that the drawdown at ing well (for artesian flow) are approximate relations any point is the summation of drawdowns produced at intended to present in a simple form the results of that point by each well in the system. The drawdown more rigorous but tedious computations. The rigorous factors F to be substituted into the general equations computations were made for ratios of R/D = 4.0 and in figure 4-13 appear in the equations for both arte- 6.7 and a ratio R/rw = 1000. As a consequence, any sian and gravity flow conditions. Consequently, the agreement between experimental and computed factors given in figure 4-14 for commonly used well values cannot be expected except for the cases with arrays are applicable for either condition. these particular boundary conditions. In model studies (c) Flow and drawdown for circular well arrays at the U.S. Army Engineer Waterways Experiment can also be computed, in a relatively simple manner, Station (WES), Vicksburg, Mississippi, the flow from a by first considering the well system to be a slot, as partially penetrating well was based on the formula:
shown in figure 4-15 or 4-16. However, the piezo-Q wp = (4-2) metric head in the vicinity of the wells (or wellpoints) 1n(R/r w) 4-28
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 or (4) For gravity flow, equipotential lines intersect (4-2a) the phreatic surface at equal intervals of elevation, with each interval being a constant fraction of the total net head.
=
1n(Rr w) c. Flow nets are limited to analysis in two dimen-where sions; the third dimension in each case is assumed in-G = quantity shown in equation (6), figure 4-10 finite in extent. An example of a sectional flow net showing artesian flow from two line sources to a par-Figure 4-26 shows some of the results obtained at the tially penetrating drainage slot is given in figure 4-27a. An example of a plan flow net showing artesian inside a circular source. Also presented in figure 4-26 flow from a river to a line of relief wells is shown in are boundary curves computed for well-screen penetra- figure 4-27b.
- d. The flow per unit length (for sectional flow nets) or depth (for plan flow nets) can be computed by boundary formulas indicates fairly good agreement for means of equations (1) and (2) and (5) and (6) respec-well penetrations > 25 percent and values of R/D be- tively (fig. 4-27). Drawdowns from either sectional or tween about 5 and 15 where R/rw > 200 to 1000. plan flow nets can be computed from equations (3) and Other empirical formulas for flow from a partially (4) (fig. 4-27). In plan flow nets for artesian flow, the netrating well suffer from the same limitations. equipotential lines correspond to various values of H-(4) Partially penetrating wells. The equations for h, whereas for gravity flow, they correspond to H2-h2.
gravity flow to partially penetrating wells are only Since section equipotential lines for gravity flow con-considered valid for relatively high-percent penetra- ditions are curved rather than vertical, plan flow nets tions. for gravity flow conditions give erroneous results for large drawdowns and should always be used with cau-4-3. Flow-net analyses.
tion.
- a. Flow nets are valuable where irregular configura-tions of the source of seepage or of the dewatering sys- e. Plan flow nets give erroneous results if used to tem make mathematical analyses complex or impossi- analyze partially penetrating drainage systems, the er-ble. However, considerable practice in drawing and ror being inversely proportional to the percentage of studying good flow nets is required before accurate penetration. They give fairly accurate results if the flow nets can be constructed. penetration of the drainage system exceeds 80 percent and if the heads are adjusted as described in the fol-
- b. A flow net is a graphical representation of flow of lowing paragraph.
water through an aquifer and defines paths of seepage (flow lines) and contours of equal piezometric head f. In previous analyses of well systems by means of (equipotential lines). A flow net may be constructed to flow nets, it was assumed that dewatering or drainage represent either a plan or a section view of a seepage wells were spaced sufficiently close to be simulated by a continuous drainage slot and that the drawdown pattern. Before a sectional flow net can be con-structed, boundary conditions affecting the flow pat- (H-hD) required to dewater an area equaled the aver-age drawdown at the drainage slot or in the lines of tern must be delineated and the pervious formation transformed into one where kn = kv (app E). In draw- wells (H-h,). These analyses give the amount of flow ing a flow net, the following general rules must be ob- QT that must be pumped to achieve H-hD but do not served: give the drawdown at the wells. The drawdown at the (1) Flow lines and equipotential lines intersect at wells required to produce H-ho downstream or within right angles and form curvilinear squares or rec- a ring of wells can be computed (approximately) for ar-tangles. tesian flow from plan flow nets by the equations (2) The flow between any two adjacent flow lines shown in figure 4-28 if the wells have been spaced proportional to the flow lines as shown in figure 4-27.
and the head loss between any two adjacent equipoten-tial lines are equal, except where the plan or section The drawdown at fully penetrating gravity wells can cannot be divided conveniently into squares, in which also be computed from equations given in figure 4-28.
case a row of rectangles will remain with the ratio of the lengths to the sides being constant. 4-4. Electrical analogy seepage models.
(3) A drainage surface exposed to air is neither an a. The laws governing flow of fluids through porous equipotential nor flow line, and the squares at this sur- media and flow of electricity through pure resistance face are incomplete; the flow and equipotential lines are mathematically similar. Thus, it is feasible to use need not intersect such a boundary at right angles. electrical models to study seepage flows and pressure 4-29
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 NOTE B O T T O M O F A L L W E L L 5 S E A L E D (I.E. INSULATED IN MODEL).
U.S. Army Corps of Engineers Figure 4-26. Shape factors for wells of various penetrations centered inside a circular source.
4-30
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 4-27. Flow and drawdown to slots computed from flow nets.
distribution for various seepage conditions. Both two- (previously identified as equation (1) in fig. 4-27) and three-dimensional models can be used to solve through soil can be expressed for unit length of soil seepage problems. formations as follows:
(4-3)
- b. Darcys law for two-dimensional flow of water 4-31
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Army Corps of Engineers Figure 4-28. Flow and drawdown to wells computed from flow-net analyses.
4-32
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 Since the permeability in fluid flow is analogous to the flow net constructed using an electrical analogy model reciprocal of the specific resistance for geometrically may be analyzed in the same manner as one con-similar mediums, the shape factors for Darcys law and structed as in paragraph 4-3.
Ohms law are the same.
- d. A two-dimensional flow net can be constructed e. Equipment for conducting three-dimensional using a scale model of the flow and drainage system electrical analogy model studies is available at the made of a conductive material representing the porous WES. The equipment consists basically of a large media (graphite-treated paper or an electrolytic solu- plexiglass tank filled with diluted copper sulfate solu-tion), copper or silver strips for source of seepage and tion and having a calibrated, elevated carrier assembly drainage, and nonconductive material representing for the accurate positioning of a point electrode probe impervious flow boundaries. The electrical circuit con- anywhere in the fluid medium. A prototype is simu-sists of a potential applied across the model and a lated by fabricating appropriately shaped and sealed Wheat&one bridge to control intermediate potentials source and sink configurations and applying an elec-on the model (fig. 4-29). The flow net is constructed by trical potential across them. The model is particularly tracing lines of constant potential on the model, thus useful for analyzing complex boundary conditions that establishing the flow-net equipotential lines after cannot be readily analyzed by two-dimensional tech-which the flow lines are easily added graphically. A niques.
(Fruco & Associates. Inc.)
U.S. Army Corps of Engineers Figure 4-29. Diagrammatic layout of electrical analogy model.
4-33
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 4-5. Numerical analyses. from 4 to 18 inches with a screen 20 to 75 feet long de-pending on the flow and pump size requirements.
- a. Many complex seepage problems, including such (1) Well screens. Screens generally used for de-categories as steady confined, steady unconfined, and watering wells are slotted (or perforated) steel pipe, transient unconfined can be solved using the finite ele-perforated steel pipe wrapped with galvanized wire, ment method. Various computer codes are available at galvanized wire wrapped and welded to longitudinal the WES and the NAVFAC program library to handle rods, and slotted polyvinyl chloride (PVC) pipe. Riser a variety of two- and three-dimensional seepage prob-pipes for most dewatering wells consist of steel or PVC lems. The codes can handle most cases of nonhomoge-pipe. Screens and riser for permanent wells are usually neous and anisotropic media.
made of stainless steel or PVC. Good practice dictates
- b. A general computer code for analyzing partially the use of a filter around dewatering wells, which per-penetrating random well arrays has been developed mits the use of fairly large slots or perforations, usual-based on results of three-dimensional electrical anal- ly 0.025 to 0.100 inch in size. The slots in well screens ogy model tests at the WES. The computer code pro- should be as wide as possible but should meet criteria vides a means for rapidly analyzing trial well systems given in c below.
in which the number of wells and their geometric con- (2) Open screen area. The open area of a well figuration can be varied to determine quantities of screen should be sufficient to keep the entrance veloc-seepage and head distributions. Wells of different ity for the design flow low to reduce head losses and to radii and penetrations can be considered in the analy- minimize incrustation of the well screen in certain sis. types of water. For temporary dewatering wells in-stalled in nonincrusting groundwater, the entrance ve-4-6. Wellpoints, wells, and filters. Wells locity should not exceed about 0.15 to 0.20 foot per and wellpoints should be of a type that will prevent in- second; for incrusting groundwater, the entrance ve-filtration of filter material or foundation sand, offer locity should not exceed 0.10 to 0.20 foot per second.
little resistance to the inflow of water, and resist cor- For permanent drainage wells, the entrance velocity rosion by water and soil. Wellpoints must also have should not exceed about 0.10 foot per second. As the sufficient penetration of the principal water-carrying flow to and length of a well screen is usually dictated strata to intercept seepage without excessive residual by the characteristics of the aquifer and drawdown re-head between the wells or within the dewatered area. quirements, the required open screen area can be ob-
- a. Wellpoints. Where large flows are anticipated, a tained by using a screen of appropriate diameter with high-capacity type of wellpoint should be selected. The a maximum amount of open screen area.
inner suction pipe of self-jetting wellpoints should per- (3) Well hydraulics. Head losses within the well mit inflow of water with a minimum hydraulic head system discussed in paragraph 4-2a(5) can be esti-loss. Self-jetting wellpoints should be designed so that mated from figure 4-24.
most of the jet water will go out the tip of the point, c. Filters. Filters are usually 3 to 5 inches thick for with some backflow to keep the screen flushed clean wellpoints and 6 to 8 inches thick for large-diameter while jetting the wellpoint in place. wells (fig. 4-30). To prevent infiltration of the aquifer (1) Wellpoint screens. Generally, wellpoints are materials into the filter and of filter materials into the covered with 30- to 60-mesh screen or have an equiva- well or wellpoint, without excessive head losses, filters lent slot opening (0.010 to 0.025 inch). The mesh should meet the following criteria:
should meet filter criteria given in c below. Where the Screen-filter criteria soil to be drained is silty or fine sand, the yield of the wellpoint and its efficiency can be greatly improved by placing a relatively uniform, medium sand filter Filter-aquifer criteria around the wellpoint. The filter should be designed in Max filter D15 Max filter D50 accordance with criteria subsequently set forth in c be-low. A filter will permit the use of screens or slots with Min aquifer D85 Min aquifer D50 larger openings and provide a more pervious material around the wellpoint, thereby increasing its effective Min filter D15 radius (d below). Max aquifer D15 (2) Wellpoint hydraulics. The hydraulic head If the filter is to be tremied in around the screen for a losses in a wellpoint system must be considered in de- well or wellpoint, it may be either uniformly or rather signing a dewatering system. These losses can be esti- widely graded; however, if the filter is not tremied mated from figure 4-25. into place, it should be quite uniformly graded (D90/D10
- b. Wells. Wells for temporary dewatering and per-manent drainage systems may have diameters ranging continuous stream to minimize segregation.
4-34
TM 88-5, Chap 6/NAVFAC P-418 TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418
- d. Effective well radius. The effective radius rw of crustation or mechanical wear caused by prolonged a well is that well radius which would have no hy- operation. This equipment should also be designed draulic entrance loss Hw. If well entrance losses are with appropriate valves, crossovers, and standby units considered separately in the design of a well or system so that the system can operate continuously, regard-of wells, rw for a well or wellpoint without a filter may less of interruption for routine maintenance or break-be considered to be one-half the outside diameter of down.
the well screens; where a filter has been placed around a. Centrifugal and wellpoint pumps.
a wellpoint or well screen, rw may generally be con- (1) Centrifugal pumps can be used as sump sidered to be one-half the outside diameter or the pumps, jet pumps, or in combination with an auxiliary radius of the filter. vacuum pump as a wellpoint pump. The selection of a
- e. Well penetration. In a stratified aquifer, the ef- pump and power unit depends on the discharge, suc-fective well penetration usually differs from that com- tion lift, hydraulic head losses, including velocity head puted from the ratio of the length of well screen to to- and discharge head, air-handling requirement, power tal thickness of the aquifer. A method for determining available, fuel economy, and durability of unit. A well-the required length of well screen W to achieve an ef- point pump, consisting of a self-priming centrifugal fective penetration W in a stratified aquifer is given in pump with an attached auxiliary vacuum pump, appendix E. should have adequate air-handling capacity and be
- f. Screen length, penetration, and diameter. The capable of producing a vacuum of at least 22 to 25 feet length and penetration of the screen depends on the of water in the headers. The suction lift of a wellpoint thickness and stratification of the strata to be de- pump is dependent on the vacuum available at the watered (para 4-2a(6)). The length and diameter of the pump bowl, and the required vacuum must be con-screen and the area of perforations should be suffi- sidered in determining the pumping capacity of the cient to permit the inflow of water without exceeding pump. Characteristics of a typical 8-inch wellpoint the entrance velocity given in b(2) above. The wetted pump are shown in figure 4-31. Characteristics of a screen length hws (or hw for each stratum to be de- typical wellpoint pump vacuum unit are shown in fig-watered) is equal to or greater than Qw/qc (para 4-2a(4) ure 4-32. Sump pumps of the centrifugal type should and (6)). The diameter of the well screen should be at be self-priming and capable of developing at least 20 least 3 to 4 inches larger than the pump bowl or motor. feet of vacuum. Jet pumps are high head pumps; typ-ical characteristics of a typical 6-inch jet pump are 4-7. Pumps, headers, and discharge shown in figure 4-33.
pipes. The capacity of pumps and piping should al- (2) Each wellpoint pump should be provided with low for possible reduction in efficiency because of in- one connected standby pump so as to ensure continuity (Courtesy of Griffin Wellpoint Corp. and Foundation Engineering, McGraw Hill Book Company)
Figure 4-31. Characteristics of 8-inch Griffin wellpoint pump.
4-36
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Army Corps of Engineers Figure 4-33. Characteristics of 6-inch jet pump.
4-37
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Courtesy of Layne & Bowler, Inc., Memphis, Tenn.)
Figure 4-34. Deep-well turbine pump.
of operation in event of pump or engine failure, or for b. Deep-well pumps.
repair or maintenance. By overdesigning the header (1) Deep-well turbine or submersible pumps are pipe system and proper placement of valves, it may be generally used to pump large-diameter deep wells and possible to install only one standby pump for every consist of one or more stages of impellers on a vertical two operational pumps. If electric motors are used for shaft (fig. 4-34). Turbine pumps can also be used as powering the normally operating pumps, the standby sump pumps, but adequate stilling basins and trash pumps should be powered with diesel, natural or LP racks are required to assure that the pumps do not be-gas, or gasoline engines. The type of power selected come clogged. Motors of most large-capacity turbine will depend on the power facilities at the site and the pumps used in deep wells are mounted at the ground economics of installation, operation, and maintenance. surface. Submersible pumps are usually used for It is also advisable to have spare power units on site in pumping deep, low-capacity wells, particularly if a addition to the standby pumping units. Automatic vacuum is required in the well.
switches, starters, and valves may be required if fail- (2) In the design of deep-well pumps, consider-ure of the system is critical. ation must be given to required capacity, size of well 4-38
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 Table 4-2. Capacity of Various Size Submersible and Deep- Well Turbine Pumps Approximate Maximum Pump Inside Diameter Maximum Capacity Bowl or Motor Size of Well gallons per minute inches inches Deep Well Submersible 4 5-6 90 70 5 6-8 160 --
6 8-10 450 250 8 10-12 600 400 10 12-14 1,200 700 12 14-16 1,800 1,100 14 16-18 2,400 --
16 18-20 3,000 --
U. S. Army Corps of Engineers screen and riser pipe, total pumping head, and the low-ered elevation of the water in the well. The diameter of the pump bowl must be determined before the wells are installed, as the inside diameter of the well casing should be at least 3 to 4 inches larger in diameter than the pump bowl. Approximate capacities of various tur-bine pumps are presented in table 4-2. The character-istics of a typical three-stage, lo-inch turbine pump are shown in figure 4-35.
(3) Submersible pumps require either electric power from a commercial source or one or more motor generators. If commercial power is used, 75 to 100 per-cent of (connected) motor generator power, with auto-matic starters unless operational personnel are on duty at all times, should be provided as standby for the commercial power. Spare submersible pumps, general- (Courtesy of Fairbanks Morse, Inc., Pump Division) ly 10 to 20 percent of the number of operating pumps, Figure 4-35. Rating curves for a three-stage 10-inch-high capacity as well as spare starters, switches, heaters, and fuses, deep-wellpump.
should also be kept at the site.
(4) Deep-well turbine pumps can be powered with to connect the header pipe to a 30- or 36-inch collec-either electric motors or diesel engines and gear tion tank about 20 or 30 feet deep, sealed at the bot-drives. Where electric motors are used, 50 to 100 per- tom and top, and pump the flow into the tank with a cent of the pumps should be equipped with combina- high-capacity deepwell turbine pump using a separate tion gear drives connected to diesel (standby) engines. vacuum pump connected to the top of the tank to pro-The number of pumps so equipped would depend upon duce the necessary vacuum in the header pipe for the the criticality of the dewatering or pressure relief wells or wellpoints.
needs. Motor generators may also be used as standby d. Header pipe.
for commercial power. For some excavations and sub-(1) Hydraulic head losses caused by flow through surface conditions, automatic starters may be required the header pipe, reducers, tees, fittings, and valves for the diesel engines or motor generators being used should be computed and kept to a minimum (1 to 3 as backup for commercial power. feet) by using large enough pipe. These losses can be
- c. Turbovacuum pumps. For some wellpoint sys- computed from equivalent pipe lengths for various fit-tems requiring high pumping rates, it may be desirable tings and curves.
4-39
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (2) Wellpoint header pipes should be installed as close as practical to the prevailing groundwater eleva-tion and in accessible locations. Wellpoint pumps should be centrally located so that head losses to the ends of the system are balanced and as low as possible.
If suction lift is critical, the pump should be placed low enough so that the pump suction is level with the header, thereby achieving a maximum vacuum in the header and the wellpoints. If construction is to be per-formed in stages, sufficient valves should be provided in the header to permit addition or removal of portions of the system without interrupting operation of the re-mainder of the system. Valves should also be located to permit isolation of a portion of the system in case In stratified subsurface soils, such as a course-grained construction operations should break a swing connec- pervious stratum overlain by a finer grained stratum tion or rupture a header. of relatively low permeability, most of the head loss (3) Discharge lines should be sized so that the through the entire section would probably occur.
head losses do not create excessive back pressure on through the finer grained material. Consequently, a the pump. Ditches may be used to carry the water factor of safety based on the head loss through the top from the construction site, but they should be located stratum would probably indicate a more critical condi-well back of the excavation and should be reasonably tion than if the factor of safety was computed from the watertight. total head loss through the entire section. Also, when gradients in anisotropic soils are determined from 4-8. Factors of safety. flow nets, the distance over which the head is lost
- a. General. The stability of soil in areas of seepage must be obtained from the true section rather than the emergence is critical in the control of seepage. The exit transformed section.
gradient at the toe of a slope or in the bottom of an ex- c. Piping. Piping cannot be analyzed by any rational cavation must not exceed that which will cause surface method. In a study of piping beneath hydraulic struc-raveling or sloughing of the slope, piping, or heave of tures founded on granular soils, it was recommended the bottom of the excavation. that the (weighted) creep ratio Cw should equal or ex-
- b. Uplift. Before attempting to control seepage, an ceed the values shown in table 4-3 for various types of analysisshould be made to ensure that the seepage or granular soils.
uplift gradient is equal to or less than that computed from the following equations:
Table 4-3. Minimum Creep Ratios for Various Granular Soils Soil Creep Ratio Very fine sand or silt 8.5 Fine sand 7 Medium sand 6 Coarse sand 5 Fine gravel 4 Medium gravel 3.5 Coarse gravel including cobbles 3 Boulders with some cobbles and gravel 2.5 From Security from Under-Seepage Masonry Dams, by E. W. Lone, pp. 1235-1272.
Transactions, American Society of Civil Engineers, 1935.
4-40
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 where H - he represents vertical distance from the acteristics of the subsurface soils, stratification, and groundwater table to the bottom of the excavation. groundwater table; the incompleteness of the data and These criteria for piping are probably only applicable accuracy of the formulations on which the design is to dewatering of sheeted, cellular, or earth-dike coffer- based; the reduction in the efficiency of the dewater-dams founded on granular soils. Once piping develops, ing system with time; the frailties of machines and op-erosion of the soil may accelerate rapidly. As the erating personnel; and the criticality of failure of the length of seepage flow is reduced, the hydraulic gradi- system with regard to safety, economics, and damage ent and seepage velocity increase, with a resultant ac- to the project. All of these factors should be considered celeration in piping and erosion. Piping can be con- in selecting the factor of safety. The less information trolled by lowering the groundwater table in the exca- on which the design is based and the more critical the vated slopes or bottom of an excavation, or in either dewatering is to the success of the project, the higher less critical situations or emergencies by placement of the required factor of safety. Suggested factors of filters over the seepage exit surface to prevent erosion safety and design procedures are as follows:
of the soil but still permit free flow of the seepage. The (1) Select or determine the design parameters as gradation of the filter material should be such that the accurately as possible from existing information.
permeability is high compared with the aquifer, yet (2) Use applicable design procedures and equa-fine enough that aquifer materials will not migrate tions set forth in this manual.
into or through the filter. The filter should be designed (3) Consider the above enumerated factors in on the basis of criteria given in paragraph 4-6c. More selecting a factor of safety.
than one layer of filter material may be required to (4) Evaluate the experience of the designer.
stabilize a seeping slope or bottom of an excavation in (5) After having considered steps l-4, the follow-order to meet these criteria. ing factors of safety are considered appropriate for
- d. Dewatering systems. As in the design of any modifying computed design values for flow, draw-works, the design of a dewatering system should in- down, well spacing, and required wetted screen clude a factor of safety to cover the variations in char- length.
Factor of Safety for Design (FS = 1.0 + (a+ b+c))
Factor to be Added to 1.0 (a) Design Data Poor 0.25 Fair 0.20 Good 0.10 Excellent 0.05 (b) Experience of Designer Little 0.25 Some 0.20 Good 0.10 Excellent 0.05 (c) Criticality Great 0.25 Moderate 0.20 Little 0.15 Application of Factor of Safety to Computed Values or System Design Features Computed Value System Design Feature Design Procedure Remarks Pump capacity, header, and dis- Increase Q to FS .....................
charge pipe (Q)
Drawdown (Ah) Adjust either drawdown or well spacing, but not Well spacing (a) Decrease a by 10 percent both Wetted screen length hws) h w s .....................
Note: In initially computing drawdown, well spacing, and wetted screen, use flow and other pa-rameters unadjusted for factor of safety.
4-41
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 In addition to these factors of safety being applied to that they can be pumped in the event pumping of the design features of the system, the system should be bottom stage of wellpoints does not lower the water pump-tested to verify its adequacy for the maximum table below the excavation slope because of stratifica-required groundwater lowering and maximum river or tion, and so that they can be pumped during backfill-groundwater table likely (normally a frequency of oc- ing operations.
currence of once in 5 to 10 years for the period of expo- (a) The design of a conventional wellpoint sys-sure) to occur. tem to dewater an open excavation, as discussed in paragraph 4-2b, is outlined below.
4-9. Dewatering open excavations. An ex- Step 1. Select dimensions and groundwater co-cavation can be dewatered or the artesian pressure re- efficients (H, L, and k) of the formation to be de-lieved by one or a combination of methods described in watered based on investigations outlined in chapter 3.
chapter 2. The design of dewatering and groundwater Step 2. Determine the drawdown required to control systems for open excavations, shafts, and tun- dewater the excavation or to dewater down to the next nels is discussed in the following paragraphs. Ex- stage of wellpoints, based on the maximum ground-amples of design for various types of dewatering and water level expected during the period of operation.
pressure relief systems are given in appendix D. Step 3. Compute the head at the assumed slot
- a. Trenching and sump pumping. (he or ho) to produce the desired residual head hD in the (1) The applicability of trenches and sump pump- excavation.
ing for dewatering an open excavation is discussed in Step 4. Compute the flow per lineal foot of chapter 2. Where soil conditions and the depth of an drainage system to the slot QP.
excavation below the water table permit trenching and Step 5. Assume a wellpoint spacing a and com-sump pumping of seepage (fig. 2-1), the rate of flow pute the flow per wellpoint, QW = aQp.
into the excavation can be estimated from plan and Step 6. Calculate the required head at the well-sectional flow analyses (fig. 4-27) or formulas pre- point hw corresponding to Qw.
sented in paragraphs 4-2 through 4-5. Step 7. Check to see if the suction lift that can (2) Where an excavation extends into rock and be produced by the wellpoint pump V will lower the there is a substantial inflow of seepage, perimeter water level in the wellpoint to h,(p) as follows:
drains can be installed at the foundation level outside (4-8) of the formwork for a structure. The perimeter drain- where age system should be connected to a sump sealed off V = vacuum at pump intake, feet of water from the rest of the area to be concreted, and the seep- M = distance from base of pervious strata to age water pumped out. After construction, the drain- pump intake, feet age system should be grouted. Excessive hydrostatic H C = average head loss in header pipe from well-pressures in the rock mass endangering the stability of point, feet the excavated face can be relieved by drilling 4-inch- HW = head loss in wellpoint, riser pipe, and swing diameter horizontal drain holes into the rock at ap- connection to header pipe, feet proximately lo-foot centers. For large seepage inflow, Step 8. Set the top of the wellpoint screen at supplementary vertical holes for deep-well pumps at least 1 to 2 feet or more below hw-Hw to provide ade-50- to 100-foot intervals may be desirable for tempo- quate submergence of the wellpoint so that air will not rary lowering of the groundwater level to provide suit- be pulled into the system.
able conditions for concrete placement. (b) An example of the design of a two-stage well-
- b. Wellpoint system. The design of a line or ring of point system to dewater an excavation is illustrated in wellpoints pumped with either a conventional well- figure D-1, appendix D.
point pump or jet-eductors is generally based on math- (c) If an excavation extends below an aquifer ematical or flow-net analysis of flow and drawdown to into an underlying impermeable soil or rock forma-a continuous slot (para 4-2 through 4-5). tion, some seepage will pass between the wellpoints at (1) Conventional wellpoint system. The draw- the lower boundary of the aquifer. This seepage may down attainable per stage of wellpoints (about 15 feet) be intercepted with ditches or drains inside the excava-is limited by the vacuum that can be developed by the tion and removed by sump pumps. If the underlying pump, the height of the pump above the header pipe, stratum is a clay, the wellpoints may be installed in and hydraulic head losses in the wellpoint and collec- holes drilled about 1 to 2 feet into the clay and back-tor system. Where two or more stages of wellpoints are filled with filter material. By this procedure, the water required, it is customary to design each stage so that it level at the wellpoints can be maintained near the bot-is capable of producing the total drawdown required tom of the aquifer, and thus seepage passing between by that stage with none of the upper stages function- the wellpoints will be minimized. Sometimes these ing. However, the upper stages are generally left in so procedures are ineffective, and a small dike in the ex-4-42
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 cavation just inside the toe of the excavation may be of the jet nozzle in the pump. Generally, a jet-eductor required to prevent seepage from entering the work pump requires an input flow of about 2 to 21/2 times area. Sump pumping can be used to remove water the flow to be pumped depending on the operating from within the diked area. pressure and design of the nozzle. Consequently, if (2) Jet-eductor (well or) wellpoint systems. Flow flow from the wells or wellpoints is large, a deep-well and drawdown to a jet-eductor (well or) wellpoint sys- system will be more appropriate. The pressure header tem can be computed or analyzed as discussed in para- supplying a system of jet eductors must be of such size graph 4-2b. Jet-eductor dewatering systems can be de- that a fairly uniform pressure is applied to all of the signed as follows: eductors.
Step 1. Assume the line or ring of wells or well- (3) Vacuum wellpoint system. Vacuum wellpoint points to be a drainage slot. systems for dewatering fine-grained soils are similar Step 2. Compute the total flow to the system for to conventional wellpoint systems except the wellpoint the required drawdown and penetration of the well and riser are surrounded with filter sand that is sealed screens. at the top, and additional vacuum pump capacity is Step 3. Assume a well or wellpoint spacing that provided to ensure development of the maximum vac-will result in a reasonable flow for the well or well- uum in the wellpoint and filter regardless of air loss.
point and jet-eductor pump. In order to obtain 8 feet of vacuum in a wellpoint and Step 4. Compute the head at the well or well- filter column, with a pump capable of maintaining a point hw required to achieve the desired drawdown. 25 foot vacuum in the header, the maximum lift is Step 5. Set eductor pump at M = hw-Hw with 25-8 or 17 feet. Where a vacuum type of wellpoint some allowance for future loss of well efficiency. system is required, the pump capacity is small. The ca-The wells or wellpoints and filters should be selected pacity of the vacuum pump will depend on the air per-and designed in accordance with the criteria set forth meability of the soil, the vacuum to be maintained in under paragraph 4-6. the filter, the proximity of the wellpoints to the exca-(a) If the soil formation being drained is strati- vation, the effectiveness of the seal at the top of the fied and an appreciable flow of water must be drained filter, and the number of wellpoints being pumped. In down through the filter around the riser pipe to the very fine-g-rained soils, pumping must be continuous.
wellpoint, the spacing of the wellpoints and the perme- The flow may be so small that water must be added to ability of the filter must be such that the flow from the system to cool the pump properly.
formations above the wellpoints does not exceed Q w = kv A i c. Electroosmosis (4-9) (1) An electroosmotic dewatering system consists where of anodes (positive electrodes, usually a pipe or rod)
Q w = flow from formation above wellpoint K v = vertical permeability of filter and cathodes (negative electrodes, usually wellpoints A = horizontal area of filter or small wells installed with a surrounding filter),
i = gradient produced by gravity = 1.0 across which a d-c voltage is applied. The depth of the Substitution of small diameter well screens for well- electrodes should be at least 5 feet below the bottom of points may be indicated for stratified formations. the slope to be stabilized. The spacing and arrange-Where a formation is stratified or there is little avail- ment of the electrodes may vary, depending on the able submergence for the wellpoints, jet-eductor well- dimensions of the slope to be stabilized and the voltage points and risers should be provided with a pervious available at the site. Cathode spacings of 25 to 40 feet filter, and the wellpoints set at least 10 feet back from have been used, with the anodes installed midway be-the edge of a vertical excavation. tween the cathodes. Electrical gradients of 1.5- to 4-(b) Jet-eductor pumps may be powered with volts-per-foot distance between electrodes have been individual small high-pressure centrifugal pumps or successful in electroosmotic stabilization. The electri-with one or two large pumps pumping into a single cal gradient should be less than about 15 volts per foot pressure pipe furnishing water to each eductor with a of distance between electrodes for long-term installa-single return header. With a single-pump setup, the tions to prevent loss in efficiency due to heating the water is usually circulated through a stilling tank with ground. Applied voltages of 30 to 100 volts are usually an overflow for the flow from wells or wellpoints (fig. satisfactory; a low voltage is usually sufficient if the 2-6). Design of jet eductors must consider the static groundwater has a high mineral content.
lift from the wells or wellpoints to the water level in (2) The discharge of a cathode wellpoint may be the recirculation tank; head loss in the return riser estimated from the equation pipe; head loss in the return header; and flow from the Qe = keieaz (4-10) wellpoint. The (net) capacity of a jet-eductor pump de- where pends on the pressure head, input flow, and diameter k e = coefficient of electroosmotic permeability 4-43
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (assume 0.98 x 10-4 feet per second per volt groundwater completely to the bottom of the aquifer, per foot) A combination of deep wells and a single stage of well-l e = electrical gradient between electrodes, volts points may permit lowering to the desired level. The per foot advantages of a combined system, in which wells are a = effective spacing of wellpoints, feet essentially used in place of the upper stages of well-z = depth of soil being stabilized, feet points, are as follows:
Current requirements commonly range between 15 (a) The excavation quantity is reduced by the and 30 amperes per well, and power requirements are elimination of berms for installation and operation of generally high. However, regardless of the expense of the upper stages of wellpoints.
installation and operation of an electroosmotic de- (b) The excavation can be started without a de-watering system, it may be the only effective means of lay to install the upper stages of wellpoints.
dewatering and stabilizing certain silts, clayey silts, (c) The deep wells installed at the top of the and clayey silty sands. Electroosmosis may not be excavation will serve not only to lower the groundwa-applicable to saline soils because of high current re- ter to permit installation of the wellpoint system but quirements, nor to organic soils because of environ- also to intercept a significant amount of seepage and mentally objectionable effluents, which may be un- thus reduce the flow to the single stage of wellpoints.
sightly and have exceptionally high pH values. A design example of a combined deep-well and well-
- d. Deep-well systems point system is shown in figure D-4.
(1) The design and analysis of a deep-well system (2) Sand drains with deep wells and wellpoints.
to dewater an excavation depends upon the configura- Sand drains can be used to intercept horizontal seep-tion of the site dewatered, source of seepage, type of age from stratified deposits and conduct the water flow (artesian and gravity), penetration of the wells, vertically downward into a pervious stratum that can and the submergence available for the well screens be dewatered by means of wells or wellpoints. The lim-with the required drawdown at the wells. Flow and iting feature of dewatering by sand drains is usually drawdown to wells can be computed or analyzed as dis- the vertical permeability of the sand drains itself, cussed in paragraph 4-2b. which restricts this method of drainage to soils of low (2) Methods are presented in paragraphs 4-2b and permeability that yield only a small flow of water.
4-3 whereby the flow and drawdown to a well system Sand drains must be designed so that they will inter-can be computed either by analysis or by a flow net as- cept the seepage flow and have adequate capacity to suming a continuous slot to represent the array of allow the seepage to drain downward without any back wells, and the drawdown at and between wells com- pressure. To accomplish this, the drains must be puted for the actual well spacing and location. Exam- spaced, have a diameter, and be filled with filter sand ples of the design of a deep-well system using these so that methods and formulas are presented in figures D-2 (4-11) and D-3. where (3) The submerged length and size of a well screen QD = flow per drain should be checked to ensure that the design flow per k D = vertical permeability of sand filter well can be achieved without excessive screen entrance i = gradient produced by gravity = 1.0 losses or velocities. The pump intake should be set so A D = area of drain that adequate submergence (a minimum of 2 to 5 feet) Generally, sand drains are spaced on 5- to 15-foot cen-is provided when all wells are being pumped. Where ters and have a diameter of 10 to 18 inches. The maxi-the type of seepage (artesian and gravity) is not well mum permeability kv of a filter that may be used to established during the design phase, the pump intake drain soils for which sand drains are applicable is should be set 5 to 10 feet below the design elevation to about 1000 to 3000 x 10-4 centimetres per second or ensure adequate submergence. Setting the pump bowl 0.20 to 0.60 feet per minute, Thus, the maximum ca-below the expected drawdown level will also facilitate pacity QD of a sand drain is about 1 to 3 gallons per drawdown measurements. minute. An example of a dewatering design, including
- e. Combined systems. sand drains, is presented in figure D-5. The capacity (1) Well and wellpoint systems. A dewatering sys- of sand drains can be significantly increased by install-tem composed of both deep wells and wellpoints may ing a small (1- or 11/2-inch) slotted PVC pipe in the be appropriate where the groundwater table has to be drain to conduct seepage into the drain downward into lowered appreciably and near to the top of an im- underlying more pervious strata being dewatered.
permeable stratum. A wellpoint system alone would f. Pressure relief systems.
require several stages of wellpoints to do the job, and a (1) Temporary relief of artesian pressure beneath well system alone would not be capable of lowering the an open excavation is required during construction 4-44
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 where the stability of the bottom of the excavation is 1 pound per square inch per foot of depth of the injec-endangered by artesian pressures in an underlying tion.
aquifer. Complete relief of the artesian pressures to a (a) Portland cement is best adapted to filling level below the bottom of the excavation is not always voids and fractures in rock and has the advantage of required depending on the thickness, uniformity, and appreciably strengthening the formation, but it is inef-permeability of the materials. For uniform tight shales fective in penetrating the voids of sand with an effec-or clays, an upward seepage gradient i as high as 0.5 to tive grain size of 1 millimetre or less. To overcome this 0.6 may be safe, but clay silts or silts generally require deficiency, chemical grouts have been developed that lowering the groundwater 5 to 10 feet below the bot- have nearly the viscosity of water, when mixed and in-tom of the excavation to provide a dry, stable work jected, and later react to form a gel which seals the for-area. mation Chemical grouts can be injected effectively in-(2) The flow to a pressure relief system is artesian; to soils with an effective grain size D10 that is less than therefore, such a system may be designed or evaluated 0.1 millimetre. Cement grout normally requires a day on the basis of the methods presented in paragraphs or two to hydrate and set, whereas chemical grout can 4-2 and 4-3 for artesian flow. The penetration of the be mixed to gel in a few minutes.
wells or wellpoints need be no more than that required (b) Cement grouts are commonly mixed at wa-to achieve the required drawdown to keep the flow to ter-cement ratios of from 5:1 to 10:1 depending on the the system a minimum. If the aquifer is stratified and grain size of the soils. However, the use of a high wa-anisotropic, the penetration required should be deter- ter-cement ratio will result in greater shrinkage of the mined by computing the effective penetration into the cement, so it is desirable to use as little water as practi-transformed aquifer as described in appendix E. Ex- cal. Bentonite and screened fly ash may be added to a amples of the design of a wellpoint system and a deep- cement grout to both improve the workability and re-well system for relieving pressure beneath an open ex- duce the shrinkage of the cement. The setting time of a cavation are presented in figures D-6 and D-7. cement grout can be accelerated by using a 1:1 mixture of gypsum-base plaster and cement or by adding not
- g. Cutoffs. Seepage cutoffs are used as barriers to more than 3 percent calcium chloride. High-early-flow in highly permeable aquifers in which the quanti- strength cement can be used when a short set time is ty of seepage would be too great to handle with deep- required.
well or wellpoint dewatering systems alone, or when (c) Chemical grouts, both liquid and powder-pumping costs would be large and a cutoff is more eco- based, are diluted with water for injection, with the nomical. The cutoff should be located far enough back proportions of the chemicals and admixtures varied to of the excavation slope to ensure that the hydrostatic control the gel time.
pressure behind the cutoff does not endanger the sta- (d) Injection patterns and techniques vary with bility of the slope. If possible, a cutoff should pene- grout materials, character of the formation, and geom-trate several feet into an underlying impermeable stra- etry of the grout curtains. (Grout holes are generally tum. However, the depth of the aquifer or other condi- spaced on 2- to 5-foot centers.) Grout curtains may be tions may preclude full penetration of the cutoff, in formed by successively regrouting an area at reduced which case seepage beneath the cutoff must be consid- spacings until the curtain becomes tight. Grouting is ered. Figure 4-36 illustrates the effectiveness of a par- usually done from the top of the formation downward.
tial cutoff for various penetrations into an aquifer. (e) The most perplexing problem connected with The figure also shows the soils to be homogeneous and grouting is the uncertainty about continuity and effec-isotropic with respect to permeability. If, however, the tiveness of the seal. Grout injected under pressure will soils are stratified or anisotropic with respect to per- move in the direction of least resistance. If, for exam-meability, they must be transformed into an isotropic ple, a sand deposit contains a layer of gravel, the grav-section and the equivalent penetration computed by el may take all the grout injected while the sand re-the method given in appendix E before the curves mains untreated. Injection until the grout take dimin-shown in the figure are applicable. ishes is not an entirely satisfactory measure of the suc-(1) Cement and chemical grout curtain. Pressure cess of a grouting operation. The grout may block the injection of grout into a soil or rock may be used to re- injection hole or penetrate the formation only a short duce the permeability of the formation in a zone and distance, resulting in a discontinuous and ineffective seal off the flow of water. The purpose of the injection grout curtain. The success of a grouting operation is of grout is to fill the void spaces with cement or chemi- difficult to evaluate before the curtain is complete and cals and thus form a solid mass through which no wa- in operation, and a considerable construction delay can ter can flow. Portland cement, fly ash, bentonite, and result if the grout curtain is not effective. A single row sodium silicate are commonly used as grout materials. of grout holes is relatively ineffective for cutoff pur-Generally, grouting pressures should not exceed about poses compared with an effectiveness of 2 or 3 times 4-45
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 that of overlapping grout holes. Detailed information above the groundwater table must be high enough to on grouting methods and equipment is contained in ensure that the hydrostatic pressure exerted by the TM 5-818-6. slurry will prevent caving of the sides of the trench (2) Slurry walls. The principal features of design and yet not limit operation of the excavating equip-of a slurry cutoff wall include: viscosity of slurry used ment. Neither shall the slurry be so viscous that the for excavation; specific gravity or density of slurry; backfill Will not move down through the slurry mix.
and height of slurry in trench above the groundwater Typical values of specific gravity of slurries used range table. The specific gravity of the slurry and its level from about 1.1 to 1.3 (70 to 80 pounds per cubic foot)
U.S. Army Corps of Engineers Figure 4-36. Flow beneath a partially penetrating cutoff wall.
4-46
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC p-418 with sand or weighting material added: The viscosity tem can be designed to lower the water table below the of the slurry for excavating slurry wall trenches usual- tunnel or bottom of the shaft using methods and for-ly ranges from a Marsh funnel reading of 65 to 90 sec- mulas presented in paragraphs 4-1 through 4-4. If the onds, as required to hold any weighting material add- soil or rock formation is stratified, the wells must be ed and to prevent any significant loss of slurry into the screened and filtered through each pervious stratum, walls of the trench. The slurry should create a pressure as well as spaced sufficiently close so that the residual in the trench approximately equal to 1.2 times the ac- head in each stratum being drained is not more than 1 tive earth pressure of the surrounding soil. Where the or 2 feet. Dewatering stratified soils penetrated by a soil at the surface is loose or friable, the upper part of shaft or tunnel by means of deep wells may be facili-the trench is sometimes supported with sand bags or a tated by sealing the wells and upper part of the riser concrete wall. The backfill usually consists of a mix- pipe and applying a vacuum to the top of the well and ture of soil (or a graded mix of sand-gravel-clay) and correspondingly to the filter. Maintenance of a vac-bentonite slurry with a slump of 4 to 6 inches. uum in the wells and surrounding earth tends to stabil-(3) Steel sheet piling. Seepage cutoffs may be cre- ize the earth and prevent the emergence of seepage in-ated by driving a sheet pile wall or cells to isolate an to the tunnel or shaft.
excavation in a river or below the water table. Sheet c. In combined well-vacuum systems, it is necessary piles have the advantage of being commonly available to use pumps with a capacity in excess of the maxi-and readily installed. However, if the soil contains cob- mum design flow so that the vacuum will be effective bles or boulders, a situation in which a cutoff wall is for the full length of the well screen. Submersible applicable to dewatering, the driving may be very dif- pumps installed in sealed wells must be designed for ficult and full penetration may not be attained. Also, the static lift plus friction losses in the discharge pipe obstructions may cause the interlocks of the piling to plus the vacuum to be maintained in the well. The split, resulting in only a partial cutoff. pumps must also be designed so that they will pump (a) Seepage through the sheet pile interlocks water and a certain amount of air without cavitation.
should be expected but is difficult to estimate. As an The required capacity of the vacuum pump can be esti-approximation, the seepage through a steel sheet pile mated from formulas for the flow of air through por-wall should be assumed equal to at least 0.01 gallon ous media considering the maximum exposure of the per square foot of wall per foot of net head acting on tunnel facing or shaft wall at any one time to be the the wall. The efficiency of a sheet pile cutoff is sub- most pervious formation encountered, assuming the stantial for short paths of seepage but is small or negli- porous stratum to be fully drained. The flow of air gible for long paths. through a porous medium, assuming an ideal gas flow-(b) Sheet pile cutoffs that are installed for long- ing under isothermal conditions, is given in the follow-term operation will usually tighten up with time as the ing formula:
interlocks become clogged with rust and possible in- (4-12) crustation by the groundwater.
(4) Freezing. Freezing the water in saturated por- where ous soils or rock to form an ice cutoff to the flow of Qa = flow of air at mean pressure of air in flow groundwater may be applicable to control of ground-water for shafts or tunnels where the excavation is P = pressure differential p1-p2) in feet of water small but deep. (See para 4-12 for information on de- p1 = absolute atmospheric pressure sign and operation of freezing systems.) p2 = absolute air pressure at line of vacuum wells D = thickness of aquifer, feet 4-10. Dewatering shafts and tunnels. hW = head at well, feet
- a. The requirements and design of systems for de- k= coefficient of permeability for water, feet per watering shafts and tunnels in cohesionless, porous minute soil or rock are similar to those previously described w = absolute viscosity of water for open excavations. As an excavation for a shaft or a = absolute viscosity of air tunnel is generally deep, and access is limited, deep- = geometric seepage shape factor (para 4-3) wells or jet-eductor wellpoints are considered the best method for dewatering excavations for such structures The approximate required capacity of vacuum pump is where dewatering techniques can be used. Grout cur- expressed as tains, slurry cutoff walls, and freezing may also be used to control groundwater adjacent to shafts or tun-nels.
- b. Where the soil or rock formation is reasonably homogeneous and isotropic, a well or jet-eductor sys-4-47
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 orable site for artificial freezing is where the water ta-ble is high, the soil is, e.g., a running sand, and the wa-ter table cannot be drawn down because of possible damage to existing structures of water (in a coarser 15- to 20-foot centers have been used to dewater cais- granular material). The freezing technique may be the sons and mine shafts 75 to 250 feet deep. An example best way to control water in some excavations, e.g.,
of the design of a deep-well system supplemented with deep shafts.
vacuum in the well filter and screen to dewater a (2) Frozen soil not only is an effective water bar-stratified excavation for a shaft is shown in figure rier but also can serve as an excellent cofferdam. An D-8, and an example to dewater a tunnel is shown in example is the frozen cofferdam for an open excava-figure D-9. tion 220 feet in diameter and 100 feet deep in rub
- d. In designing a well system to dewater a tunnel or bishy fill, sands, silts, and decomposed rock. A frozen shaft, it should be assumed that any one well or pump- curtain wall 4000 feet long and 65 feet deep has been ing unit may go out of operation. Thus, any combina- successfully made but only after some difficult prob-tion of the other wells and pumping units must have lems had been solved. Mine shafts 18 feet in diameter sufficient capacity to provide the required water table and 2000 feet deep have been excavated in artificially lowering or pressure relief. Where electrical power is frozen soils and rocks where no other method could be used to power the pumps being used to dewater a shaft used. Any soil or fractured rock can be frozen below or tunnel, a standby generator should be connected to the water table to form a watertight curtain provided the system with automatic starting and transfer equip- the freeze-pipes can be installed, but accurate site data ment or switches. are essential for satisfactory design and operation.
- b. Design. As with the design of any system for sub 4-11. Permanent pressure relief sys- surface water control, a thorough site study must first tems. Permanent drainage or pressure relief systems be made. Moving water is the factor most likely to can be designed using equations and considerations cause failure; a simple sounding-well or piezometer previously described for various groundwater and flow layout (or other means) must be used to check this. If conditions. The well screen, collector pipes, and filters the water moves across the excavation at more than should be designed for long service and with access about 4 feet per day, the designer must include extra provided for inspection and reconditioning during the provisions to reduce the velocity, or a curtain wall may life of the project. Design of permanent relief or drain-never close. If windows show up in the frozen curtain age systems should also take into consideration poten-wall, flooding the excavation and refreezing with add-tial encrustation and screen loss. The system should ed freeze-pipes are nearly always necessary. A knowl-preferably be designed to function as a gravity system edge of the creep properties of the frozen soils may be without mechanical or electrical pumping and control needed; if the frozen soil is used as a cofferdam or equipment. Any mechanical equipment for the system earth retaining structure, such can be determined should be selected for its simplicity and dependability from laboratory tests. Thermal properties of the soils of operation. If pumping equipment and controls are can usually be reliably estimated from published data, required, auxiliary pump and power units should be using dry unit weight and water content.
provided. Piezometers and flow measuring devices should be included in the design to provide a means for c. Operation. The ground is frozen by closed-end, controlling the operation and evaluating its efficiency. steel freeze-pipes (usually vertical, but they can be driven, placed, or jacked at any angle) from 4 to 6 4-12. Freezing. inches in diameter, spaced from 3 to 5 feet in one or
- a. General. more rows to an impervious stratum. If there is no im-(1) The construction of a temporary waterstop by pervious stratum within reach, the soil may be com-artificially freezing the soil surrounding an excavation pletely frozen as a block in which the excavation is site is a process that has been used for over a century, made, or an impervious stratum may be made artifi-not always with success and usually as a last resort cially. In one project, a horizontal disk about 200 feet when more conventional methods had failed. The across and 24 feet thick was frozen at a minimum method may be costly and is time-consuming. Until re- depth of 150 feet. Then, a cylindrical cofferdam 140 cent years far too little engineering design has been feet in diameter was frozen down to the disk, and the used, but nowadays a specialist in frozen-soil engineer- enclosed soil was excavated without any water prob-ing, given the site information he needs, can design a lem.
freezing system with confidence. However, every job (1) Coaxial with each freeze-pipe is a 11/2 to 2-inch needs care in installation and operation and cannot be steel, or plastic, supply pipe delivering a chilled liquid left to a general contractor without expert help. A fav- (coolant) to the bottom of the closed freeze pipe. The 4-48
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 coolant flows slowly up the annulus between the pipes, are often wasted in construction; they are sometimes pulls heat from the ground, and progressively freezes used for thawing the soil back to normal, in which case the soil. (A typical freeze-pipe is shown in fig. 4-37.) they could be pulled afterward.
After a week or two, the separate cylinders of frozen d. Important considerations. The following items soil join to form the barrier, which gradually thickens must be considered when the freezing technique is to to the designed amount, generally at least 4 feet (walls be used:
of 24-foot thickness with two rows of freeze-pipes have (1) Water movement in soil.
been frozen in large and deep excavations in soft or- (2) Location of freeze-pipes. (The spacing of ganic silts). The total freeze-time varies from 3 to 4 freeze-pipes should not exceed the designed amount by weeks to 6 months or more but is predictable with high more than 1 foot anywhere along the freeze wall.)
accuracy, and by instrumentation and observation the (3) Wall closure. (Freeze-pipes must be accurately engineer has good control. Sands of low water content located, and the temperature of the soil to be frozen freeze fastest; fine-grained soils of high water content carefully monitored with thermocouples to ensure 100 take more time and total energy, although the refriger- percent closure of the wall. Relief wells located at the ation horsepower required may be greater than for center of a shaft may also be used to check the prog-sands. ress of freezing. By periodically pumping these wells, (2) The coolant is commonly a chloride brine at the effectiveness of the ice wall in sealing off seepage zero to -20 degrees Fahrenheit, but lower tempera- flow can be determined.)
tures are preferable for saving time, reducing the (4) Frost-heave effects-deformations and pres-amount of heat to be extracted, and minimizing frost- sures. (Relief wells may be used to relieve pressures heave effects (which must be studied beforehand). In caused by expansion of frozen soil.)
recent years, liquid propane at -45°F has been used (5) Temperature effects on buried utilities.
in large projects, and for small volumes of soil, liquid (6) Insulation of aboveground piping.
nitrogen that was allowed to waste has been used. (7) Control of surface water to prevent flow to the (These cryogenic liquids demand special care-they are freezing region.
dangerous.) Coolant circulation is by headers, com- (8) Coolant and ground temperatures. (By moni-monly 8-inch pipes, connected to a heat-exchanger at toring coolant and soil temperatures, the efficiency of the refrigeration plant using freon (in a modern plant) the freezing process can be improved.)
as the refrigerant. The refrigeration equipment is us- (9) Scheduling of operations to minimize lost time ually rented for the job. A typical plant requires from when freezing has been completed.
50 horsepower and up; 1000 horsepower or more has (10) Standby plant. (Interruption of coolant circu-sometimes been used. Headers should be insulated and lation may be serious. A standby plant with its own are recoverable. Freeze-pipes may be withdrawn but prime movers is desirable so as to prevent any thaw. A continuous advance of the freezing front is not neces-sary so that standby plant capacity is much less than that normally used.)
4-13. Control of surface water.
- a. Runoff of surface water from areas surrounding the excavation should be prevented from entering the excavation by sloping the ground away from the exca-vation or by the construction of dikes around the top of the excavation. Ditches and dikes can be construct-ed on the slopes of an excavation to control the runoff of water and reduce surface erosion. Runoff into slope ditches can be removed by pumping from sumps in-stalled in these ditches, or it can be carried in a pipe or lined ditch to a central sump in the bottom of the exca-vation where it can be pumped out. Dikes at the top of an excavation and on slopes should have at least 1 foot of freeboard above the maximum elevation of water to be impounded and a crown width of 3 to 5 feet with (From Tunnel Driven Using Subsurface Freezing. by C. P. Gail, pp. 37-40. side slopes of 1V on 2-2.5H.
Civil Engineering. American Society of Civil Engineers. May 1972.)
- b. In designing a dewatering system, provision must Figure 4-37. Typical freeze-pipe. be made for collecting and pumping out surface water 4-49
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 so that the dewatering wells and pumps cannot be into the excavation or from the drainage area into the flooded. Control of surface water within the diked area excavation from the equation will not only prevent interruption of the dewatering operation, which might seriously impair the stability of the excavation, but also prevent damage to the con-struction operations and minimize interruption of where work. Surface water may be controlled by dikes, c = coefficient of runoff ditches, sumps, and pumps; the excavation slope can R = rainfall for assumed rainstorm, inches be protected by seeding or covering with fabric or as- A = area of excavation plus area of drainage into phalt. Items to be considered in the selection and de- excavation, acres sign of a surface water control system include the dur- (The value of c depends on relative porosity, character, ation and season of construction, rainfall frequency and slope of the surface of the drainage area. For im-and intensity, size of the area, and character of surface pervious or saturated steep excavations, c values may soils. be assumed to range from 0.8 to 1.0.)
Step 4. Plot values of VR versus assumed dura-
- c. The magnitude of the rainstorm that should be tion of rainstorm.
used for design depends on the geographical location, Step 5. Plot pumpage rate of pump to be in-risk associated with damage to construction or the de-stalled assuming pump is started at onset of rain.
watering system, and probability of occurrence during This method is illustrated by figure D-10.
construction. The common frequency of occurrence used to design surface water control sumps and pumps g. The required ditch and sump storage volume is is a once in 2-to 5-year rainfall. For critical projects, a the (maximum) difference between the accumulated frequency of occurrence of once in 10 years may be ad- runoff for the various assumed rainstorms and the visable . amount of water that the sump pump (or pumps) will remove during the same elapsed period of rainfall. The
- d. Impounding runoff on excavation slopes is some- capacity and layout of the ditches and sumps can be what risky because any overtopping of the dike could adjusted to produce the optimum design with respect result in overtopping of all dikes at lower elevations to the number, capacity, and location of the sumps and with resultant flooding of the excavation. pumps.
- e. Ample allowance for silting of ditches should be h. Conversely, the required capacity of the pumps made to ensure that adequate capacities are available for pumping surface runoff depends upon the volume throughout the duration of construction. The grades of of storage available in sumps, as well as the rate of ditches should be fairly flat to prevent erosion. Sumps runoff (see equation (3-3)). For example, if no storage should be designed that will minimize siltation and is available, it would be necessary to pump the runoff that can be readily cleaned. Water from sumps should at the rate it enters the excavation to prevent flooding.
not be pumped into the main dewatering system. This method usually is not practicable. In large excava-tions, sumps should be provided where practicable to
- f. The pump and storage requirements for control of reduce the required pumping capacity. The volume of surface water within an excavation can be estimated in sumps and their effect on pump size can be determined the following manner: graphically (fig. D-10) or can be estimated approxi-Step 1. Select frequency of rainstorm for which mately from the following equation:
pumps, ditches, and sumps are to be designed.
Step 2. For selected frequency (e.g., once in 5 years), determine rainfall for 10-, 30-, and 60-minute rainstorms at project site from figure 3-6.
Step 3. Assuming instantaneous runoff, com-pute volume of runoff VR (for each assumed rainstorm) 4-50
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 CHAPTER 5 INSTALLATION OF DEWATERING AND GROUNDWATER CONTROL SYSTEMS 5-1. General. The successful performance of any mied in. The tremie pipe should be 4 to 5 inches in dia-dewatering system requires that it be properly in- meter, be perforated with slots ¹/16 to ³/32 inch wide and stalled. Principal installation features of various types about 6 inches long, and have flush screw joints. The of dewatering or groundwater control systems are pre- slots will allow the filter material to become saturated, sented in the following paragraphs. thereby breaking the surface tension and bulking of the filter in the tremie. One or two slots per linear foot 5-2. Deep-well systems. of tremie is generally sufficient. After the tremie pipe
- a. Deep wells may be installed by the reverse-rotary has been lowered to the bottom of the hole, it should be drilling method, by driving and jetting a casing into filled with filter material, and then slowly raised, the ground and cleaning it with a bailer or jet, or with keeping it full of filter material at all times, until the a bucket auger. filter material is 5 to 10 feet above the top of the
- b. In the reverse-rotary method, the hole for the screen, The filter material initially poured in the tre-well is made by rotary drilling, using a bit of a size re- mie should be wasted in the bottom of the hole. The quired by the screen diameter and thickness of filter. level of drilling fluid or water in a reverse-rotary Soil from the drilling is removed from the hole by the drilled hole must be maintained at least 7 feet above flow of water circulating from the ground surface the natural groundwater level until all the filter ma-down the hole and back up the (hollow) drill stem from terial is placed. If a casing is used, it should be pulled the bit. The drill water is circulated by a centrifugal or as the filter material is placed, keeping the bottom of jet-eductor pump that pumps the flow from the drill the casing 2 to 10 feet below the top of the filter ma-stem into a sump pit. As the hole is advanced, the soil terial as the filter is placed. A properly designed, uni-particles settle out in the sump pit, and the muddy water flows back into the drill hole through a ditch cut out tremieing if it is poured in around the screen in a from the sump to the hole. The sides of the drill hole heavy continuous stream to minimize segregation.
are stabilized by seepage forces acting against a thin d. After the filter is placed, the well should be devel-film of fine-grained soil that forms on the wall of the oped to obtain the maximum yield and efficiency of hole. A sufficient seepage force to stabilize the hole is the well. The purpose of the development is to remove produced by maintaining the water level in the hole at any film of silt from the walls of the drilled hole and to least 7 feet above the natural water table. No bento- develop the filter immediately adjacent to the screen nite drilling mud should be used because of gelling in to permit an easy flow of water into the well. Develop-the filter and aquifer adjacent to the well. If the hole is ment of a well should be accomplished as soon after drilled in clean sands, some silt soil may need to be the hole has been drilled as practicable. Delay in doing added to the drilling water to attain the desired degree this may prevent a well being developed to the effi-of muddiness (approximately 3000 parts per million). ciency assumed in design. A well may be developed by (Organic drilling material, e.g., Johnsons Revert or surge pumping or surging it with a loosely fitting equivalent, may also be added to the drilling water to surge block that is raised and lowered through the well reduce water loss.) The sump pit should be large screen at a speed of about 2 feet per second. The surge enough to allow the sand to settle out but small enough block should be slightly flexible and have a diameter 1 so that the silt is kept in suspension. to 2 inches smaller than the inside diameter of the well
- c. Holes for deep wells should be vertical so that the screen. The amount of material deposited in the bot-screen and riser may be installed straight and plumb; tom of the well should be determined after each cycle appropriate guides should be used to center and keep (about 15 trips per cycle). Surging should continue un-the screen plumb and straight in the hole. The hole til the accumulation of material pulled through the should be some deeper than the well screen and riser. well screen in any one cycle becomes less than about (The additional depth of the hole is to provide space 0.2 foot deep. The well screen should be bailed clean if for wasting filter material first put in the tremie pipe the accumulation of material in the bottom of the if used.) After the screen is in place. the filter is tre- screen becomes more than 1 to 2 feet at any time dur-5-1
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 ing surging, and recleaned after surging is completed. g. After the wells are developed and satisfactorily Material bailed from a well should be inspected to see tested by pumping, the pumps, power unite, and dis-if any foundation sand is being removed. It is possible charge piping may be installed.
to oversurge a well, which may breach the filter with
- h. Where drawdown or vacuum requirements in resulting infiltration of foundation sand when the well deep wells demand that the water level be lowered and is pumped. maintained near the bottom of the wells, the pumps
- e. After a well has been developed, it should be will have to handle a mixture of water and air. If such pumped to clear it of muddy water and sand and to a requirement exists, the pump bowls should be de-check it for yield and infiltration. The well should be signed to allow increasing amounts of air to enter the pumped at approximately the design discharge from bowl, which will reduce the efficiency of the pump un-30 minutes to several hours, with periodic measure- til the pump capacity just equals the inflow of water, ment of the well flow, drawdown in the well, depth of without cavitation of the impellers. The impellers of sand in the bottom of the well, and amount of sand in deep-well turbine pumps should be set according to the the discharge. Measurements of well discharge and manufacturers recommendations. Improper impeller drawdown may be used to determine the efficiency settings can significantly reduce the performance of a and degree of development of the well. The perfor- deep-well pump.
mance of the well filter may be evaluated by measur-ing the accumulation of sand in the bottom of the well 5-3. Wellpoint systems.
and in the discharge. A well should be developed and a. Wellpoint systems are installed by first laying pumped until the amount of sand infiltration is less the header at the location and elevation called for by than 5 to 10 parts per million. the plans as illustrated in figure 5-1. After the header
- f. Deep wells, in which a vacuum is to be main- pipe is laid, the stopcock portion of the swing connec-tained, require an airtight seal around the well riser tion should be connected to the header on the spacing pipe from the ground surface down for a distance of 10 called for by the design, and all fittings and plugs in to 50 feet. The seal may be made with compacted clay, the header made airtight using a pipe joint compound nonshrinking grout or concrete, bentonitic mud, or a to prevent leakage. Installation of the wellpoints gen-short length of surface casing capped at the top. Im- erally follows layout of the header pipe.
proper or careless placement of this seal will make it b. Self-jetting wellpoints are installed by jetting impossible to attain a sufficient vacuum in the system them into the ground by forcing water out the tip of to cause the dewatering system to operate as designed. the wellpoint under high pressure. The jetting action The top of the well must also be sealed airtight. of a typical self-jetting wellpoint is illustrated in fig-Plan of a typical wellpoint system.
(From Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure 5-1. Plan of a typical wellpoint system.
5-2
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 ure 5-2. Self-jetting wellpoints can be installed in me- using a hole puncher and a jet casing to form the hole dium and fine sand with water pressures of about 50 for the wellpoint and filter. When the wellpoint reach-pounds per square inch. Wellpoints jetted into coarse es grade and before the water is turned off, the two sand and gravel require considerably more water and halves of a swing connection, if used, should be lined higher water pressures (about 125 pounds per square up for easy connection when the jet water is turned off inch) to carry out the heavier particles; either a hy- and the jetting hose disconnected.
drant or a jetting pump of appropriate size for the pressures and quantities of jetting water required can c. Where a wellpoint is to be installed with a filter be used. The jetting hose, usually 2 to 3 inches in diam- (i.e. sanded), generally the wellpoint should be in-eter, is attached to the wellpoint riser, which is picked stalled in a hole formed by jetting down a 10- to 12-up either by a crane or by hand and held in a vertical inch heavy steel casing. The casing may be fitted with position as the jet water is turned on. The wellpoint is a removable cap at the top through which air and wat-allowed to sink slowly into the ground and is slowly er may be introduced. The casing is jetted into the raised and lowered during sinking to ensure that all ground with a return of air and water along the out-fine sand and dirt are washed out of the hole. Care side of the casing. Jetting pressures of 125 pounds per should be taken to ensure that a return of jet water to square inch are commonly used; where resistant strata the surface is maintained; otherwise, the point may are encountered, the casing may have to be raised and freeze before it reaches grade. If the return of jet wa- dropped with a crane to chop through and penetrate to ter disappears, the point should be quickly raised until the required depth. A casing may also be installed us-circulation is restored and then slowly relowered. In ing a combination jetting and driving tool, equipped gravelly soils, it may be necessary to supplement the with both water and air lines, which fits inside the cas-jet water with a separate air supply at about 125 ing and extends to the bottom of the casing. Most of pounds per square inch to lift the gravel to the surface. the return water from a hole puncher rises inside the If filter sand is required around the wellpoint to in- casing, causing considerably less disturbance of the ad-crease its efficiency or prevent infiltration of founda- jacent foundation soils. After the casing is installed to tion soils, the wellpoints generally should be installed a depth of 1 to 3 feet greater than the length of the as-(Courtesy of Griffin Wellpoint Corp.)
Figure 5-2. Self-jetting wellpoint.
5-3
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 sembled wellpoint, the jet is allowed to run until the possible vacuum, the suction intake of the pump casing is flushed clean with clear water. should be set level with the header pipe. Wellpoint
- d. The wellpoint is placed in the casing, the sand fil- pumps should be protected from the weather by a shel-ter tremied or poured in, and the casing pulled. Care ter and from surface water or sloughing slopes by should be taken to center the wellpoint in the casing so ditches and dikes. The discharge pipe should be water-that it is completely surrounded with filter material. tight and supported independently of the pump.
Before the wellpoint is connected to the header, it f. Vacuum wellpoint systems are installed in the should be pumped to flush it and the filter and to same manner as ordinary wellpoint systems using a jet check it for sanding. All joints connecting wellpoints casing and filter, except the upper 5 feet of the riser is to the header should be made airtight to obtain the sealed airtight to maintain the vacuum in the filter.
maximum needed vacuum. g. Jet-eductor wellpoints are usually installed using
- e. Wellpoint pumps, similar to that shown in figure a hole puncher and surrounding the wellpoint and ris-5-3, are used to provide the vacuum and to remove er pipe with filter sand. Jet eductors are connected to water flowing to the system. To obtain the maximum two headers-one for pressure to the eductors and (Courtesy of Moretrench American Corp.)
Figure 5-3. Characteristic parts of a wellpoint pump.
5-4
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 another for return flow from the eductors and the velop in the pressure supply line from the pump to the wellpoints back to the recirculation tank and pressure grout injection pipe, the line must occasionally be pump. flushed to ensure that the grout being pumped into the formation is homogeneous and has the correct viscos-5-4. Vertical sand drains. Vertical sand drains ity. The grout in a single-line system is flushed can be installed by jetting a 12- to 18-inch casing into through a blowoff valve onto the ground surface and the soil to be drained; thoroughly flushing the casing wasted. A recirculating system has a return line to the with clear water; filling it with clean, properly graded grout storage tank so that the grout is constantly be-filter sand; and pulling the casing similar to installing ing circulated through the supply line, with a tap off to sanded wellpoints. It is preferable to place the filter the injection pipe where desired.
sand through a tremie to prevent segregation, which (4) Additional information on grouting is con-may result in portions of the filter being too coarse to tained in TM 5-818-6.
filter fine-grained soils and too fine to permit vertical drainage. Sand drains should penetrate into the under- b. Slurry walls.
lying pervious aquifer to be drained by means of wells (1) Slurry cutoff trenches can be dug with a or wellpoints. trenching machine, backhoe, dragline, or a clam buck-et, typically 2 to 5 feet wide, The walls of the trench 5-5. Cutoffs. are stabilized with a thick bentonitic slurry until the
- a. Cement and chemical grout curtains. trench can be backfilled. The bentonitic slurry is best (1) Cement or chemical grouts are injected mixed at a central plant and delivered to the trench in through pipes installed in the soil or rock. Generally, trucks or pumped from slurry ponds. The trench is car-pervious soil or rock formations are grouted from the ried to full depth by excavation through the slurry, top of the formation downward. When this procedure with the trench being maintained full of slurry by the is followed, the hole for the grout pipe is first cored or addition of slurry as the trench is deepened and ex-drilled down to the first depth to be grouted, the grout tended.
pipe and packer set, and the first zone grouted. After (2) With the trench open over a limited length and the grout is allowed to set, the hole is redrilled and ad- to full depth, cleaning of the slurry is commenced in vanced for the second stage of grouting, and the above order to remove gravelly or sandy soil particles that procedure repeated. This process is repeated until the have collected in the slurry, especially near the bottom entire depth of the formation has been grouted. No of the trench. Fair cleanup can be obtained using a drilling mud should be used in drilling holes for grout clamshell bucket; more thorough cleaning can be ob-pipes because the sides of the hole will be plastered tained by airlifting the slurry to the surface for circu-with the mud and little, if any, penetration of grout lation through desanding units. Cleaning of the slurry will be achieved. makes it less viscous and ensures that the slurry will (2) Mixing tanks and pump equipment for pres- be displaced by the soil-bentonite backfill. After clean-sure injection of cement or chemical grouts vary de- ing the in-trench slurry, the trench is generally back-pending upon the materials being handled. Ingredients filled with a well-graded mix of sand-clay-gravel and for a grout mix are loaded into a mixing tank equipped bentonite slurry with a slump of about 4 to 6 inches.
with an agitator and, from there, are pumped to a stor- The backfill material and slurry may be mixed either age tank also equipped with an agitator. Pumps for along and adjacent to the trench or in a central mixing grouting with cement are generally duplex, positive plant and delivered to the trench in trucks.
displacement, reciprocating pumps similar to slush (3) The backfill is introduced at the beginning of pumps used in oil fields. Cement grouts are highly the trench so as to displace the slurry toward the ad-abrasive, so the cylinder liners and valves should be of vancing end of the trench. In the initial stages of back-case-hardened steel. Chemical grouts, because of their fill, special precautions should be taken to ensure that low viscosity and nonabrasive nature, can be pumped the backfill reaches the bottom of the trench and that with any type of pump that produces a satisfactory it assumes a proper slope (generally 1V on 5H to 1V on pressure. Grout pump capacities commonly range 10H). In order to achieve this slope, the first backfill from 20 to 100 gallons per minute at pressures rang- should be placed by clamshell or allowed to flow down ing from 0 to 500 pounds per square inch. The maxi- an inclined ramp, dug at the beginning end of the mum grout pressure used should not exceed about 1 trench. As the surface of the backfill is built up to the pound per square inch times the depth at which the top of the trench, digging the trench resumes as shown grout is being injected. in figure 5-4. As the backfill is bulldozed into the back (3) The distribution system for grouting may be of the trench, it flows down the sloped face of the al-either of two types: a single-line system or a recircu- ready placed backfill, displacing slurry as it advances.
lating system. Because of segregation that may de- Proper control of the properties of the slurry and back-5-5
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 fill is required to ensure that the slurry is not trapped c. Steel sheet piling. Steel sheet pile cutoffs are con-within the backfill. structed employing the same general techniques as (4) The backfill should be placed continuously as those used for driving steel sheet piles. However, pre-the trench is advanced. By so doing, sloughing of the cautions should be taken in handling and driving sheet trench walls will be minimized, and the amount of ben- piling to ensure that the interlocks are tight for the tonitic slurry required kept to a minimum. The level of full depth of the piling and that all of the sheets are the slurry in the trench should be maintained at least 5 driven into the underlying impermeable stratum at all feet above the groundwater table. Care should be tak- locations along the sheet pile cutoff. Methods and en to control the density and viscosity of the bentoni- techniques for driving steel sheet piling are described tic slurry as required by the design. To minimize wast- in numerous references on this subject.
age of bentonitic slurry, it may be necessary to screen d. Freezing. Freezing the soil around a shaft or tun-out sand and gravel in order to reuse the slurry. (Con- nel requires the installation of pipes into the soil and struction techniques are still being developed.) circulating chilled brine through them. These pipes (5) The toe of the backfill slope should be kept generally consist of a 2-inch inflow pipe placed in a within 50 to 150 feet of the leading edge of the trench 6-inch closed-end freezing pipe installed in the to minimize the open length of the slurry-supported ground by any convenient drilling means. Two headers trench. During placement operations, excavation and are required for a freezing installation: one to carry cleaning operations proceed simultaneously ahead of chilled brine from the refrigeration plant and the oth-the advancing backfill. (It should be noted that be- er to carry the return flow of refrigerant. The refriger-cause of the geometric constraints set by the backfill ation plant should be of adequate capacity and should slope, the amount of open trench length supported by include standby or auxiliary equipment to maintain a slurry is a function of the depth of the trench. For ex- continuous operation.
ample, if the trench is 100 feet deep and the backfill slope is 1V on 8H, the open length will be about 900 to 950 feet-800 feet along the slope of the backfill face 5-6. Piezometers.
plus 100 to 150 feet from the backfill toe to the lead- a. Installation. Piezometers are installed to deter-ing edge of the trench.) mine the elevation of the groundwater table (gravity (6) When the trench is complete and the backfill or artesian) for designing and evaluating the perfor-occupies the entire trench, a compacted clay cap is nor- mance of a dewatering system. For most dewatering mally placed over the trench. Key steps in this con- applications, commercial wellpoints or small screens struction sequence involve the mixing of the bento- are satisfactory as piezometers. The selection of well-nite-water slurry, excavation and stabilization of the point or screen, slot size, need for filter, and method of trench, cleaning of the slurry, mixing of the soil-bento- installation is the same for piezometers as for dewater-nite backfill, displacement of the slurry by the back- ing wellpoints. Holes for the installation of piezomet-fill, and treatment of the top of the trench. Each of ers can be advanced using continuous flight auger with these items must be covered in the specifications. a hollow stem plugged at the bottom with a removable U.S. Army Corps of Engineers Figure 5-4. Installation of a slurry cutoff trench.
5-6
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 plug, augering with more or less simultaneous installa- center the piezometer screen in the hole in which it is tion of a casing, or using rotary wash-boring methods. to be placed.
The hole for a piezometer should be kept filled with (b) The filter sand should be poured down the water or approved drilling fluid at all times. Bentoni- hollow stem around the riser at a rate (to be deter-tic drilling mud should not be used; however, an organ- mined in the field) which will ensure a continuous flow ic type of drilling fluid, such as Johnsons Revert or of filter sand that will keep the hole below the auger equivalent, may be used if necessary to keep the filled as the auger is withdrawn. Withdrawal of the au-drilled hole open. Any auger used in advancing the ger and filling the space around the piezometer tip and hole should be withdrawn slowly from the hole so as to riser with filter sand should continue until the hole is minimize any suction effect caused by its removal. filled to a point 2 to 5 feet above the top of the piezom-When assembling piezometers, all fittings should be eter screen. Above this elevation, the space around the tight and sealed with joint compound so that water riser pipe may be filled with any clean uniform sand levels measured are those actually existing at the loca- up to the top of the particular sand stratum in which tion of the wellpoint screen. Where the water table in the piezometer is being installed but not closer than 10 different pervious formations is to be measured, the feet of the ground surface. An impervious grout seal riser pipe from the piezometer tip must be sealed from should then be placed from the top of the sand backfill the top of the screen to the ground surface to preserve to the ground surface.
the isolation of one stratum from another and to ob- (2) Casing method. The hole for a piezometer may tain the true water level in the stratum in which the be formed by setting the casing to an elevation 1 to 2 piezometer is set. Such piezometers may be sealed by feet deeper than the elevation of the piezometer tip.
grouting the hole around the riser with a nonshrinking The casing may be set by a combination of rotary drill-grout of bentonite, cement, and fly ash or other suita- ing and driving the casing. The casing should be kept ble admixture. Proportions of 1 sack of cement and 1 filled with water, or organic drilling fluid, if neces-gallon of bentonite to 10 gallons of water have been sary, to keep the bottom of the hole from blowing.
found to be a suitable grout mix for this purpose. Fly After the casing has been set to grade, it should be ash can be used to replace part of the cement to reduce flushed with water or fresh drilling fluid until clear of heat of hydration, but it does reduce the strength of any sand. The piezometer tip and riser pipe should the grout. The tops of piezometer riser pipes should be then be installed and a filter sand, conforming to that threaded and fitted with a vented cap to keep dirt and specified previously, poured in around the riser at a debris from entering the piezometer and to permit the rate (to be determined in the field) which will ensure a water level in the piezometer to adjust to any changes continuous flow of filter sand that will keep the space in the natural water table. around the riser pipe and below the casing filled as the (1) Hollow-stem auger method. casing is withdrawn without sand-locking the casing (a) After the hole for the piezometer is advanced and the riser pipe. Placement of the filter sand and to grade, 1 to 2 feet below the piezometer tip, or after withdrawal of the casing may be accomplished in steps the last sample is taken in a hole to receive a piezomet- as long as the top of the filter sand is maintained above er, the hollow-stem auger should be flushed clean with the bottom of the casing but not so much as to sand-water and the plug reinserted at the bottom of the au- lock the riser pipe and casing. Filling the space ger. The auger should then be slowly raised to the ele- around the piezometer tip and riser with filter and vation that the piezometer tip is to be installed. At this should continue until the hole is filled to a point 2 to 5 elevation, the hollow stem should be filled with clean feet above the top of the piezometer screen. An imper-water and the plug removed. Water should be added to vious grout seal should then be placed from the top of keep the stem full of water during withdrawal of the the sand backfill to the ground surface.
plug. The hole should then be sounded to determine (3) Rotary method. The hole for a piezometer may whether or not the hollow stem is open to the bottom be advanced by the hydraulic rotary method using of the auger. If material has entered the hollow stem water or an organic drilling fluid. After the hole has of the auger, the hollow stem should be cleaned by been advanced to a depth of 1 or 2 feet below the pie-flushing with clear water, or fresh Johnsons Revert or zometer tip elevation, it should be flushed with clear equivalent drilling fluid if necessary to stabilize the water or clean drilling fluid, and the piezometer, filter bottom of the hole, through a bit designed to deflect sand, sand backfill, and grout placed as specified above the flow of water upward, until the discharge is free of for the casing method, except there will be no casing to soil particles. The piezometer screen and riser should pull.
then be lowered to the proper depth inside the hollow b. Development and testing. The piezometer should stem and the filter sand placed. A wire spider should be flushed with clear water and pumped after installa-be attached to the bottom of the piezometer screen to tion and then checked to determine if it is functioning 5-7
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 properly by filling with water and observing the rate types of soil:
Approximate of fall. A lo-foot minimum positive head should be Period of Time of Type of Soil in maintained in the piezometer following breakdown of Which Piezometer Observation 50 Percent Fall the drilling fluid. After at least 30 minutes have Screen Is Set minutes minutes elapsed, the piezometer should be flushed with clear Sandy silt (>50% silt) 30 30 water and pumped. For the piezometer to be consid- Silty sand (<50% silt, ered acceptable, it should pump at a rate of at least 2 >12% silt) 10 5 gallons per minute, or when the piezometer is filled Fine sand 5 1 with water, the water level should fall approximately If the piezometer does not function properly, it will be half the distance to the groundwater table in a time developed by air surging or pumping with air if neces-slightly less than the time given below for various sary to make it perform properly.
5-8
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 CHAPTER 6 OPERATION AND PERFORMANCE CONTROL 6-1. General. The success of a dewatering opera- the system; the pump operator should do this daily.
tion finally hinges on the proper operation, mainte- (2) A wellpoint leaking air will frequently cause nance, and control of the system. If the system is not an audible throbbing or bumping in the swing-joint operated and maintained properly, its effectiveness connection, which may be felt by placing the hand on may soon be lost. After a dewatering or pressure relief the swing joint. The throbbing or bumping is caused by system has been installed, a full-scale pumping test intermittent charges of water hitting the elbow at the should be made and its performance evaluated for ade- top of the riser pipe, In warm weather, wellpoints that quacy or need for any modification of the system. This are functioning properly feel cool and will sweat due to test and analysis should include measurement of the condensation in a humid atmosphere. A wellpoint that initial water table, pump discharge, water table in ex- is not sweating or that feels warm may be drawing air cavation, water table in wells or vacuum in header sys- through the ground, or it may be clogged and not func-tem, and a comparison of the data with the original de- tioning. Likewise, in very cold weather, properly func-sign. tioning wellpoints will feel warm to the touch of the hand compared with the temperature of the atmos-6-2. Operation. phere, Vacuum wellpoints disconnected from the
- a. Wellpoint systems. header pipe can admit air to the aquifer and may af-(1) The proper performance of a wellpoint system fect adjacent wellpoints. Disconnected vacuum well-requires continuous maintenance of a steady, high vac- points with riser pipes shorter than 25 feet should be uum. After the system is installed, the header line and capped.
all joints should be tested for leaks by closing all (3) Wellpoint headers, swing connections, and swing-joint and pump suction valves, filling the header riser pipes should be protected from damage by con-with water under a pressure of 10 to 15 pounds per struction equipment. Access roads should cross header square inch, and checking the line for leaks. The next lines with bridges over the header to prevent damage step is to start the wellpoint pump with the pump suc- to the headers or riser connections and to provide ac-tion valve closed. The vacuum should rise to a steady cess for tuning and operating the system.
25 to 27 inches of mercury. If the vacuum on the pump b. Deep wells. Optimum performance of a deep-well is less than this height, there must be air leaks or worn system requires continuous uninterrupted operation of parts in the pump itself. If the vacuum at the pump is all wells. If the pumps produce excessive drawdowns satisfactory, the gate valve on the suction side of the in the wells, it is preferable to regulate the flow from pump may be opened and the vacuum applied to the all of the wells to match the flow to the system, rather header, with the wellpoint swing-joint valves still than reduce the number of unite operating and thus closed. If the pump creates a steady vacuum of 25 create an uneven drawdown in the dewatered area.
inches or more in the line, the header line may be con-The discharge of the wells may be regulated by vary-sidered tight. The swing-joint valves are then opened ing the pump speed (if other than electric power is and the vacuum is applied to the wellpoints. If a low, used) or by varying the discharge pressure head by unsteady vacuum develops, leaks may be present in means of a gate valve installed in the discharge lines.
the wellpoint riser pipes, or the water table has been Uncontrolled discharge of the wells may also produce lowered to the screen in some wellpoints so that air is excessive drawdowns within the well causing undesira-entering the system through one or more wellpoint ble surging and uneven performance of the pumps.
screens. One method of eliminating air entering the system through the wellpoints is to use a riser pipe 25 c. Pumps. Pumps, motors, and engines should al-feet or more in length. If the soil formation requires ways be operated and maintained in accordance with the use of a shorter riser pipe, entry of air into the sys- the manufacturers directions. All equipment should tem can be prevented by partially closing the main be maintained in first-class operating condition at all valve between the pump and the header or by adjust- times. Standby pumps and power units in operating ing the valves in the swing connections until air enter- conditions should be provided for the system, as dis-ing the system is stopped. This method is commonly cussed in chapter 4. Standby equipment may be re-used for controlling air entry and is known as tuning quired to operate during breakdown of a pumping unit 6-1
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 or during periods of routine maintenance and oil for measuring the flow from the system or wells. Pres-change of the regular dewatering equipment. All sure and vacuum gages should also be installed at the standby equipment should be periodically operated to pumps and in the header lines. For multistage well-ensure that it is ready to function in event of a break- point systems, the installation and operation of the down of the regular equipment. Automatic starters, first stage of wellpoints may offer an opportunity to clutches, and valves may be included in the standby check the permeability of the pervious strata, radius of system if the dewatering requirements so dictate. Sig- influence or distance to the source of seepage, and the nal lights or warning buzzers may be desirable to indi- head losses in the wellpoint system. Thus, from obser-cate, respectively, the operation or breakdown of a vations of the drawdown and discharge of the first pumping unit. If control of the groundwater is critical stage of wellpoints, the adequacy of the design for low-to safety of the excavation or foundation, appropriate er stages may be checked to a degree.
operating personnel should be on duty at all times. a. Piezometers. The location of piezometers should Where gravity flow conditions exist that allow the wa- be selected to produce a complete and reliable picture ter table to be lowered an appreciable amount below of the drawdown produced by the dewatering system.
the bottom of the excavation and the recovery of the Examples of types of piezometers and methods of in-water table is slow, the system may be pumped only stallation are given in paragraphs G-546) and part time, but this procedure is rarely possible or de- G-6h(2) of Appendix G. Piezometers should be located sirable. Such an operating procedure should not be at- so they will clearly indicate whether water levels re-tempted without first carefully observing the rate of quired by specifications are attained at significant lo-rise of the groundwater table at critical locations in cations. The number of piezometers depends on the the excavations and analyzing the data with regard to size and configuration of the excavation and the dewa-existing soil formations and the status of the excava- tering system. Normally, three to eight piezometers tion. are installed in large excavations and two or three in
- d. Surface water control. Ditches, dikes, sumps, and smaller excavations. If the pervious strata are strati-pumps for the control of surface water and the protec- fied and artesian pressure exists beneath the excava-tion of dewatering pumps should be maintained tion, piezometers should be located in each significant throughout construction of the project. Maintenance stratum. Piezometers should be installed at the edge of of ditches and sumps is of particular importance. Silt- and outside the excavation area to determine the ing of ditches may cause overtopping of dikes and seri- shape of the drawdown curve to the dewatering sys-ous erosion of slopes that may clog the sumps and tem and the effective source of seepage to be used in sump pumps. Failure of sump pumps may result in evaluating the adequacy of the system. If recharge of flooding of the dewatering equipment and complete the aquifer near the dewatering system is required to breakdown of the system. Dikes around the top of an prevent settlement of adjacent structures, control excavation to prevent the entry of surface water piezometers should be installed in these areas. Where should be maintained to their design section and grade the groundwater is likely to cause incrustation of well at all times. Any breaks in slope protection should be screens, piezometers may be installed at the outer edge promptly repaired. of the filter and inside the well screen to monitor the head loss through the screen as time progresses. In 6-3. Control and evaluation of perform- this way, if a significant increase in head loss is noted, ance. After a dewatering or groundwater control cleaning and reconditioning of the screens should be system is installed, it should be pump-tested to check undertaken to improve the efficiency of the system.
its performance and adequacy. This test should include Provisions for measuring the drawdown in the wells or measurement of initial groundwater or artesian water at the line of wellpoints are desirable from both an op-table, drawdown at critical locations in the excavation, eration and evaluation standpoint.
flow from the system, elevation of the water level in the wells or vacuum at various points in the header, b. Flow measurements. Measurement of flow from a and distance to the effective source of seepage, if dewatering system is desirable to evaluate the per-possible. These data should be analyzed, and if condi- formance of the system relative to design predictions.
tions at the time of test are different than those for Flow measurements are also useful in recognizing any which the system was designed, the data should be ex- loss in efficiency of the system due to incrustation or trapolated to water levels and source of seepage as- clogging of the wellpoints or well screens. Appendix F sumed in design. It is important to evaluate the system describes the methods by which flow measurements as early as possible to determine its adequacy to meet can be made.
full design requirements. Testing a dewatering system c. Operational records. Piezometers located within and monitoring its performance require the *installa- the excavated area should be observed at least once a tion of piezometers and the setting up of some means day, or more frequently, if the situation demands, to 6-2
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 ensure that the required drawdown is being main- the surrounding groundwater, and the number of wells tained. Vacuum and gages (revolutions per minute) on or wellpoints operating should be recorded and plotted pumps and engines should be checked at least every throughout the operation of the dewatering system.
few hours by the operator as he makes his rounds. The data on the performance of the dewatering system Piezometers located outside the excavated area, and should be continually evaluated to detect any irregular discharge of the system, may be observed less fre- functioning or loss of efficiency of the dewatering sys-quently after the initial pumping test of the completed tem before the construction operations are impeded, or system is concluded. Piezometer readings, flow meas- the excavation or foundation is damaged.
urements, stages of nearby streams or the elevation of 6-3
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 CHAPTER 7 CONTRACT SPECIFICATIONS 7-1. General. Good specifications are essential to tor fully responsible for obtaining the required dewa-ensure adequate dewatering and groundwater control. tering and pressure relief as proven by a full-scale Specifications must be clear, concise, and complete pumping test(s) on the system prior to start of excava-with respect to the desired results, special conditions, tion, and for all maintenance, repairs, and operations.
inspection and control, payment, and responsibility. (2) Type B-2. A specification that sets forth in The extent to which specifications should specify pro- detail the design and installation of a system that has cedures and methods is largely dependent upon the been designed to achieve the desired control of ground-complexity and magnitude of the dewatering problem, water wherein the Government or Owner assumes full criticality of the dewatering with respect to schedule responsibility for its initial performance, based on a and damage to the work, and the experience of the full-scale pumping test(s), but makes the Contractor probable bidders. Regardless of the type of specifica- responsible for maintenance and operation except for tion selected, the dewatering system(s) should be de- major repairs required over and beyond those appro-signed, installed, operated, and monitored in accord- priate to normal maintenance. (This type of specifica-ance with the principles and criteria set forth in this tion eliminates claims and contingencies commonly manual. added to bid prices for dewatering and also ensures that the Government gets a dewatering system that it 7-2. Types of specifications. has paid for and a properly dewatered excavation if
- a. Type A. Where dewatering of an excavation does the system has been designed and its installation su-not involve unusual or complex features and failure or pervised by qualified and experienced personnel.)
inadequacy of the system would not adversely affect (3) Type B-3. A specification that sets forth the the safety of personnel, the schedule, performance of desired results making the Contractor solely responsi-the work, foundation for the structure, or the com- ble for design, equipment, installation procedures, pleted work, the specifications should be one of the fol- maintenance, and performance, but requires that the lowing types: Contractor employ or subcontract the dewatering and (1) Type A-1. .A brief specification that requires groundwater control to a recognized company with at the Contractor to assume full responsibility for design, least 5 years, and preferably 10 years, of experience in installation, operation, and maintenance of an ade- the management, design, installation, and operation of quate system. (This type should not be used unless the dewatering systems of equal complexity. The specifi-issuing agency has considerable confidence in the Con- cation should also state that the system(s) must be de-tractors dewatering qualifications and has the time signed by a registered professional engineer recog-and capability to check the Contractors proposal and nized as an expert in dewatering with a minimum of 5 work.) to 10 years of responsible experience in the design and (2) Type A-2. A specification that is more de- installation of dewatering systems. This type of speci-tailed than type A-1 but still requires the Contractor fication should further require submittal of a brief but to assume the responsibility for design, installation, comprehensive report for review and approval includ-operation, and maintenance. (This type conveys more ing:
information regarding requirements of design and (a) A description and profile of the geology, soil, construction than type A- 1 while retaining the limita- and groundwater conditions and characteristics at the tions described in (1) above.) site.
- b. Type B. Where dewatering or relief of artesian (b) Design values, analyses, and calculations.
pressure is complex and of a considerable magnitude (c) Drawings of the complete dewatering sys-and is critical with respect to schedule and damage to tem(s) including a plan drawing, appropriate sections, the work, the specifications should be of one of the fol- pump and pipe capacities and sizes, power system(s),
lowing types: standby power and pumps, grades, filter gradation, (1) Type B-1. A specification that sets forth in surface water control, valving, and disposal of water.
detail the design and installation of a minimum sys- (d) A description of installation and operational tern that will ensure a basically adequate degree of wa- procedures.
tering and pressure relief but still makes the Contrac- (e) A layout of piezometers and flow measuring 7-1
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 devices for monitoring performance of the system(s). (1) If the specification is to be of Types A-1 and (f) A plan and schedule for monitoring perform- A-2 described in paragraph 7-2a(1) and (2), the de-ance of the system(s). sired results should explicitly specify the level to (g) A statement that the dewatering system(s) which the groundwater and/or piezometric surface has been designed in accordance with the principles should be lowered; give recommended factors of safety and criteria set forth in this manual. as set forth in paragraph 4-8; require that all perma-(h) The seal of the designer. nent work be accomplished in the dry and on a stable (This type of specification should not be used unless subgrade; and advise the Contractor that he is respon-the Government or Owner has or employs someone sible for designing, providing, installing, operating, competent to evaluate the report and design submit- monitoring, and removing the dewatering system by a ted, and is prepared to insist on compliance with the plan approved by the Contracting Officer or the Engi-above .) neer. This type of specification should note the limita-tions of groundwater information furnished since 7-3. Data to be included in specifica- seepage conditions may exist that were not discovered tions. All data obtained from field investigations re- during the field exploration program. It should be lating to dewatering or control of groundwater made made clear that the Contractor is not relieved of re-at the site of the project should be included with the sponsibility of controlling and disposing of all water, specifications and drawings or appended thereto. even though the discharge of the dewatering system These data should include logs of borings; soil profiles; required to maintain satisfactory conditions in the ex-results of laboratory tests including mechanical analy- cavation may be in excess of that indicated by tests or ses, water content of silts and clays, and any chemical analyses performed by the Government. This type of analyses of the groundwater; pumping tests; ground- specification should not only specify the desired re-water levels in each aquifer, if more than one, as meas- sults but also require that the Contractor provide ade-ured by properly installed and tested piezometers, and quate methods for obtaining them by means of pump-its variation with the season or with river stages; and ing from wells, wellpoint systems, cutoffs, grouting, river stages and tides for previous years if available. freezing, or any other measures necessary for particu-Borings should not only be made in the immediate vi- lar site conditions. The method of payment should also cinity of the excavation, but some borings should be be clearly specified.
made on lines out to the source of groundwater flow or (2) Prior to the start of excavation the Contractor to the estimated effective radius of influence. Suffi- should be required to submit for review a proposed cient borings should be made to a depth that will de- method for dewatering the excavation, disposing of lineate the full thickness of any substrata that would the water, and removing the system, as well as a list of have a bearing on the control of groundwater or unbal- the equipment to be used, including standby equip-anced uplift pressures. (Additional information on ment for emergency use. (This plan should be detailed field investigations and the scope of such are given in and adapted to site conditions and should provide for chap 3.) It is essential that all field or laboratory test around-the-clock dewatering operation.)
data be included with the specifications, or referenced, (3) Perimeter and diversion ditches and dikes and that the data be accurate. The availability, ade- should be required and maintained as necessary to pre-quacy, and reliability of electric power, if known, vent surface water from entering any excavation. The should be included in the contract documents. The specifications should also provide for controlling the same is true for the disposal of water to be pumped surface water that falls or flows into the excavation by from the dewatering systems. The location and owner- adequate pumps and sumps. Seepage of any water ship of water wells off the project site that might be ef- from excavated slopes should be controlled to prevent fected by lowering the groundwater level should be sloughing, and ponding of water in the excavation shown on one of the contract drawings. should be prevented during construction operations.
Any water encountered in an excavation for a shaft or 7-4. Dewatering requirements and spec- tunnel shall be controlled, before advancing the exca-ifications. The section of the specifications relating vation, to prevent sloughing of the walls or boils in to dewatering and the control of groundwater should the bottom of the excavation or blow-in of the tunnel be prepared by a geotechnical engineer experienced in face. If the flow of water into an excavation becomes dewatering and in the writing of specifications, in co- excessive and cannot be controlled by the dewatering operation with the civil designer for the project. The system that the Contractor has installed, excavation dewatering specifications may be rather general or should be halted until satisfactory remedial measures quite detailed depending upon the type of specification have been taken. Dewatering of excavations for shafts, to be issued as described in paragraph 7-2.
tunnels, and lagged open excavations should continue
- a. Type A specifications. for the duration of the work to be performed in the ex-7-2
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 cavations unless the tunnel or shaft has been securely quirements set forth for type B-3 specifications in lined and is safe from hydrostatic pressure and seep- paragraph 7-2.
age.
7-5. Measurement and payment.
(3) The specifications should also require that the Contractors plan provide for testing the adequacy of a. Payment when using types A-1 and A-2 specifi-the system prior to start of excavation and for moni- cations is generally best handled by a lump sum pay-toring the performance of the system by installing pi- ment.
ezometers and means for measuring the discharge b. Payment when using type B- 1 specifications may from the system. be based on a lump sum type, or unit prices may be set up for specific items that have been predesigned and
- b. Type B specifications. specified with lump sum payment for operational and maintenance costs.
(1) Types B-1 and B-2 specifications (para 7-2b(1) and (2)) should set forth not only the required c. Payment when using type B-2 specifications is results for dewatering, pressure relief, and surface wa- generally on the basis of various unit prices of such ter control, but also a detailed list of the materials, items as wells, pumps, and piping, in keeping with nor-equipment, and procedures that are to be used in mal payment practices for specified work. Operation achieving the desired system(s). The degree of respon- for maintenance and repairs generally should be set up sibility of the Contractor for dewatering should be as a lump sum payment with partial payment in ac-clearly set forth for specification types B-1 and B-2 as cordance with commonly accepted percentages of previously stated in paragraph 7-2. With either type work completed.
of specification, the Contractor should be advised that d. Payment when using type B-3 specifications he or she is responsible for operating and maintaining would generally be based on a lump sum type of pay-the system(s) in accordance with the manufacturers ment.
recommendation relating to equipment and in accord-
- e. Payment for monitoring piezometers and flow ance with good construction practice. The Contractor measuring devices is generally made in keeping with should also be advised that he or she is responsible for the method of payment for the various types of dewa-correcting any unanticipated seepage or pressure con-tering specifications described above.
ditions and taking appropriate measures to control such, payment for which would depend upon the type 7-6. Examples of dewatering specifica-of specification and terms of payment. tions. Examples of various types of specifications de-(2) Type B-3 specifications (para 7-2b) should in- scribed in paragraph -72, based on specifications ac-clude the basic requirements set forth above for types tually issued and accomplished in practice, are includ-A-1 and A-2 specifications plus the additional re- ed in appendix G .
7-3
TM 5-818-5/AFM 88-5, Chap 6/NAVFACP-418 APPENDIX A REFERENCES Government Publications Department of Defense Military Standard MIL-STD-619B Unified Soil Classification System for Roads, Airfield Embankments, and Foundations Departments of the Army and the Air Force TM 5-818-1/AFM 88-3, Chap. 7 Soils and Geology: Procedures for Foundation Design of Buildings and Other Structures (Except Hydraulic Structures)
TM 5-818-4/AFM 88-5, Chap. 5 Soils and Geology: Backfill for Subsurface Structures TM 5-818-6/AFM 88-32 Grouting Methods and Equipment Department of the Navy NAVFAC DM7.1 Soil Mechanics NAVFAC DM7.3 Deep Stabilization and Grouting Nongovernment Publications American Society for Testing and Materials (ASTM), 1916 Race Street, Philadelphia, PA 19103 A 108-81 Steel Bars, Carbon, Cold-Finished, Standard Quality A 743-83 Castings, Iron-Chromium, Iron-Chromium-Nickel, Nickel-Base, Corrosion Resistant for General Application BIBLIOGRAPHY NAVAC DM7.2 Foundations and Earth Structures
- U.S. GOVERNMENT PRINTING OFFICE: 1985-461-028-10160/401-M Change 1 A-1
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 APPENDIX B NOTATIONS Area of filter through which seepage is passing, drainage area, radius of a circular group of wells; area of permeability test sample, area of entrance section of pipe in measuring flow through a venturi meter or with a Pitot tube, or area of stream of water at end of pipe in jet-flow measurement Cross-section area of sand drain
-Equivalent radius of a group of wells Area of orifice Spacing of wells or wellpoints Distance between two lines of wells, length of weir crest, or circumference of a vertical pipe in fountain flow calculations Width of drainage slot, or end dimension of a rectangular drainage slot Half width of rectangular array of wells Half length of rectangular array of wells Coefficient for friction loss in pipes; coefficient for empirical relation of D10 versus k; coefficient for empirical relation of k versus R; calibrated coefficient of discharge in measuring flow through a ven-turi meter or orifice; coefficient for measuring flow with a Pitot tube; or center of a circular group of wells Coefficients for gravity flow to two slots from two-line sources Weighted creep ratio for piping Factors for drawdown in the vicinity of a gravity well Coefficient of runoff Thickness of homogeneous isotropic aquifer, or inside diameter of a discharge pipe Thickness of equivalent homogeneous isotropic aquifer Effective grain size Thickness of a pervious stratum, or pressure tap diameter Pipe diameter Orifice diameter Transformed thickness of homogeneous, isotropic pervious stratum Electrical potential difference or voltage Extra-length factor Effective area factor Factor for computing drawdown at any point due to a group of wells with circular source of seepage, or freeboard Factor for computing drawdown at any point due to a group of wells with line source of seepage Factor for computing drawdown midway between end wells of a line of wells with a circular source of seepage Factor for computing drawdown midway between end wells of a line of wells with a line source of seep-age Factor of safety Factor for computing drawdown at center of a group of wells with circular source of seepage Factor for computing drawdown at center of a group of wells with line source of seepage Factor for computing drawdown at a well m in a two-line well array with a circular source of seepage Factor for computing drawdown at a well in a group of wells with circular source of seepage Factor for computing drawdown at a well in a group of wells with line source of seepage Correction factor for a partially penetrating well from Kozenys formula or Muskats formula Groundwater table or level Acceleration of gravity, 32.2 feet per second squared Height of water table (initial) or piezometric surface, or crest height in fountain flow measurement; gravity head B-1
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 Drawdown or head differential, or residual drawdown after a pump test Drawdown expressed as Hz-H2o Head dimension in the measurement of flow with a Parshall flume Average head loss in header pipe to pump intake Friction head loss in screen entrance or filter and screen entrance Friction head loss in riser pipe and connections Friction head loss in well screen Velocity head loss in well Total hydraulic head loss in well or wellpoint Distance from bottom of sheet pile or cutoff wall to impervious boundary Head at a specific point P, head on permeability test sample in constant head permeability test; final head on permeability test sample in falling head permeability test; pressure drop across an orifice; ob-served head on crest in weir flow measurement; or head at a specific time during a pump test Height of free discharge above water level in a gravity well Head at center of a group of wells Maximum head landward from a drainage slot or line of wells, or maximum head between two slots or lines of wells Head in an artesian drainage slot, average head at a line of wells, or height of bottom of excavation in computing the creep ratio Head midway between wells, or height of mercury for pipe orifice flow measurement Head in a gravity drainage slot or at equivalent drainage slot simulating a line of wellpoints or sand drains, or initial head on permeability test sample in the falling heat permeability test Head at point P Height of free discharge above water level in drainage slot Velocity head in measuring flow with a Pitot tube Head at well, wellpoint, or sand drain Wetted screen length Head in a wellpoint that can be produced by the vacuum of a wellpoint pump Electric current or rate of flow Hydraulic gradient of seepage, well number, intensity of rainfall Electrical gradient between electrodes Drawdown at any well Constant used in jet-flow calculations Coefficient of permeability of homogeneous isotropic aquifer Transformed coefficient of permeability Coefficient of permeability for the flow of air Vertical coefficient of permeability of a sand drain Coefficient of electroosmotic permeability Effective permeability of transformed aquifer Horizontal coefficient of permeability Vertical coefficient of permeability Distance from drainage slot, well, or line of wells or wellpoints to the effective source of seepage, length of permeability test sample, or seepage length through which Ah acts in determining a seepage gradi-ent Distance from drainage slot to change from artesian to gravity flow Distance from well j to source of seepage Half the distance between two parallel drainage slots or lines of wells; long dimension of a rectangular drainage slot, or number of strata penetrated by a well in calculating effective well screen penetration Height of pump intake above base of aquifer Mean sea level Number of equipotential drops in a flow net Number of flow channels in a flow net Number of wells in system or group, or porosity, number of strata in an aquifer for transformed section calculations, or number of concentric rings in measuring flow with a Pitot tube Number of equipotential drops from seepage exit to point P B-2
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 Point at which head is computed, or factor for drawdown in the vicinity of a gravity well Mean absolute pressure inflow system Absolute atmospheric pressure Absolute air pressure at line of vacuum wells Rate of flow to a fully penetrating drainage slot per unit length of slot, capacity, or rate of pumping, or rate of surface water runoff Rate of flow of air Rated capacity of vacuum pump at atmospheric pressure Rate of flow to a sand drain Flow to well in an electroosmotic drainage system Total surface water pump capacity Rate of flow to a partially penetrating drainage slot per unit length of slot Total flow to a wellpoint system Total flow to a dewatering system Flow to a well or wellpoint Flow to an observation well Flow to well i Flow to well j Flow to a partially penetrating artesian well Rate of flow, or flow per unit length of section flow net Limiting flow into a filter or well screen Radius of influence of well, rainfall for assumed storm, or ratio of entrance to throat diameter in meas-uring flow through a venturi meter Distance from well to change from artesian to gravity flow Radius of influence of well i Radius of influence of well j Distance from well to point P, or distance from a test well to an observation piezometer Distance from image well to point P Distance from well i to point P Distance from well i to well j Radius (effective) of a well Radius (effective) of well j Coefficient of storage, the volume of water an aquifer will release from (or take into) storage per unit of surface area per unit change in head. (For artesian aquifers, S is equal to the water forced from stor-age by compression of a column of the aquifer by the additional load created by lowering the artesian pressure in the aquifer by pumping or drainage. For gravity flow aquifers, S is equal to the specific yield of the material being dewatered plus the water forced from the saturated portion of the aquifer by the increased surcharge caused by lowering the groundwater table.)
Extrapolated S value used in computations for nonequilibrium gravity flow Distance from point P to image well i Distance from image well i to well j Specific yield of aquifer (volume of water that can be drained by gravity from a saturated unit volume of material)
Height of bottom of well above bottom of aquifer Duration of rainfall, coefficient of transmissibility in square feet per minute (the coefficient of perme-ability k multiplied by the aquifer thickness D), or thickness of less pervious strata overlying a more pervious stratum Coefficient of transmissibility in gallons per day per foot width Depth of water in well, or elapsed pumping time Time for cone of drawdown to reach an impermeable boundary or a source of seepage Elapsed pumping time since pump started Elapsed time since pump stopped Time at zero drawdown or at start of pump test Argument of W(u), a well function Volume of water in permeability test, volume of sample in specific yield test, velocity, or vacuum at pump intake B-3
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 Volume of sump storage Volume of surface water runoff Velocity at center of concentric rings of equal area in measuring flow with a Pitot tube Volume of water drained in specific yield test Penetration of a drainage well, slot, or cutoff wall in a homogeneous isotropic aquifer, penetration of a between water table in a cofferdammed area and base of the sheet piling or cutoff wall, or size of flume in the measurement of flow with a Parshall flume Effective depth of penetration of a drainage slot or well into aquifer Exponential integral termed a well function Length of a drainage slot, distance from center line of excavation to sheet pile or cutoff wall, or distance along axis of a discharge pipe to a point in the stream in jet-flow measurement Distance from drainage slot to a specific line, actual vertical dimension in an anisotropic stratum, or dis-tance perpendicular to the axis of a discharge pipe to a point in the stream in jet-flow measurement Transformed vertical dimension in an anisotropic stratum Depth of soil stabilized by electroosmosis, or height of crest above bottom of approach channel in weir-flow measurement Gamma function for determining G Unit weight of water Change in piezometric head for a particular seepage length; drawdown; artesian head above bottom of slope or excavation Maximum head landward from a line of wells above head at wells Head midway between wells above that at a well Drawdown at well in a line of wells below head he at an equivalent drainage slot Change in drawdown during pump test between two different pumping rates Pressure differential Drawdown in feet per cycle of (log) time-drawdown curve in pump test Residual drawdown in feet per cycle of (log) t/t Submerged unit weight of soil Uplift factor for artesian wells or wellpoints Midpoint uplift factor for artesian wells or wellpoints Extra-length coefficient for flow to a partially penetrating drainage slot Absolute viscosity of air Absolute viscosity of water Specific resistance to electrolyte Geometric shape factor (dimensionless)
B-4
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 APPENDIX C FIELD PUMPING TESTS C-1. General. There are two basic types of pump- (2) Nonequilibrium equations are directly applica-ing tests: equilibrium (steady-state flow) and nonequi- ble to confined (artesian) aquifers and may also be used librium (transient flow). with limitations to unconfined aquifers (gravity flow
- a. Equilibrium-type test. When a well is pumped, conditions). These limitations are related to the per-the water discharged initially comes from aquifer stor- centage of drawdown in observation wells related to age adjacent to the well. As pumping continues, water the total aquifer thickness. Nonequilibrium equations is drawn from an expanding zone until a state of equi- should not be used if the drawdown exceeds 25 percent librium has been established between well discharge of the aquifer thickness at the wall. Little error is and aquifer recharge. A state of equilibrium is reached introduced if the percentage is less than 10.
when the zone of influence has become sufficiently en- c. Basic assumptions.
larged so that: natural flow into the aquifer equals the (1) Both equilibrium and nonequilibrium methods pumping rate; a stream or lake is intercepted that will for analyzing aquifer performance are generally based supply the well (fig. C-1); or vertical recharge from on the assumptions that:
precipitation on the area above the zone of influence (a) The aquifer is homogeneous and isotropic.
equals the pumping rate. If a well is pumped at a con- (b) The aquifer is infinite in extent in the hori-stant rate until the zone of drawdown has become sta- zontal direction from the well and has a constant bilized, the coefficient of permeability of the aquifer thickness.
can be computed from equilibrium formulas subse- (c) The well screen fully penetrates the pervious quently presented. formation.
- b. Nonequilibrium-type test. (d) The flow is laminar.
(1) In this type of test, the value of k is computed (e) The initial static water level is horizontal, from a relation between the rate of pumping Q, draw- (2) Although the assumptions listed above would down H at a point P near the well, distance from the seem to limit the analysis of pumping test data, in well to the point of drawdown measurement r, coeffi- reality they do not. For example, most pervious forma-cient of storage of the aquifer S, and elapsed pumping tions do not have a constant k or transmissibility time t. This relation permits determination of k from T(T = k x aquifer thickness), but the average T can aquifer performance, while water is being drawn from readily be obtained from a pumping test. Where the storage and before stabilization occurs. flow is artesian, stratification has relatively little im-(Courtesy of UOP Johnson Division)
Figure C-1. Seepage into an aquifer from an adjacent river.
C-1
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 portance if the well screen fully penetrates the aqui- and adjacent piezometers, and (e) some means for accu-fer; of course, the derived permeability for this case is rately measuring the flow from the well.
actually kh. If the formation is stratified and kh > kv, and the flow to the well is gravity in nature, the com- a. Test and observation wells. The test well should puted permeability k would be <kh and >kv. fully penetrate the aquifer to avoid uncertainties in-(3) Marked changes of well or aquifer perfor- volved in the analysis of partially penetrating wells, mance during a nonequilibrium test indicate that the and the piezometers should be installed at depths physical conditions of the aquifer do not conform to below any anticipated drawdown during the pumping the assumptions made in the development of the test. The number, spacing, and arrangement of the ob-formula for nonsteady flow to a well. However, such a servation wells or piezometers will depend on the char-departure does not necessarily invalidate the test data; acteristics of the aquifer and the geology of the area in fact, analysis of the change can be used as a tool to (figs. C-2 and C-3). Where the test well is located ad-better determine the flow characteristics of the aqui- jacent to a river or open water, one line of piezometers fer. should be installed on a line perpendicular to the river, one line parallel to the river, and, if possible, one line C-2. pumping test equipment and proce- away from the river. At least one line of piezometers dures. Determination of k from a pumping test re- should extend 500 feet or more out from the test well.
quires: (a) installation of a test well, (b) two, and pref- The holes made for installing piezometers should be erably more, observation wells or piezometers, (c) a logged for use in the analysis of the test. The distance suitable pump, (d) equipment for sounding the well from the test well to each piezometer should be meas-U.S. Army Corps of Engineers Figure C-2. Layout of piezometers for a pumping test.
C-2
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 ured, and the elevation of the top of each accurately pressure on the pump can be varied as the test pro-gresses to keep the rate of flow constant.
determined. Each piezometer should be capped with a (2) During a pumping test, it is imperative that vented cap to keep out dirt or trash and to permit the rate of pumping be maintained constant. Lowering change in water level in the piezometer without cre-ating a partial vacuum or pressure. The test well and of the water level in the well will usually cause the pumping rate to decrease unless the valve in the dis-piezometers should be carefully installed and devel-charge line is opened to compensate for the additional oped, and their performance checked by individual head or lift created on the pump. If the pump is pow-pumping or falling head tests in accordance with the ered with a gas or diesel engine, changes in tempera-procedures discussed in chapter 5 of the main text.
ture and humidity of the air may affect appreciably
- b. Pumps. the operation of the engine and thus cause variations (1) The test pump should be a centrifugal, or more in the pumping rate. Variations in line voltage may preferably, a turbine or submersible pump. It should similarly affect the speed of electric motors and thus be capable of lowering the water level in the well at the pumping rate. Any appreciable variation in pump-least 10 feet or more depending upon the characteris- ing rate should be recorded, and the cause of the varia-tics of the formation being tested. The pump should tion noted.
preferably be powered with an electric motor, or with (3) The flow from the test well must be conveyed an engine capable of operating continuously for the from the test site so that recharge of the aquifer from duration of the test. The pump discharge line should water being pumped does not occur within the zone of be equipped with a valve so that the rate of discharge influence of the test well.
can be accurately controlled. At the beginning of the
- c. Flow and drawdown measurements.
test, the valve should be partially closed so that back U.S. Army Corps of Engineers Figure C-3. Section of well and piezometers for a pumping test with gravity flow near well.
C-3
TM 5-818-5/AFM 88-5, Chap 6/NAVFA P-418 (1) The discharge from the well can be measured termine the permeability of the various strata of the by means of an orifice, pitometer, venturi, or flow- formations in order to better determine the required meter installed in the discharge pipe, or an orifice in- length and depth or well screens of wellpoints for the stalled at the end of the discharge pipe, as described in design of a dewatering or drainage system. This appendix G. The flow can also be estimated from the permeability can be determined by measuring the jet issuing from a smooth discharge pipe, or measured vertical flow within the well screen at various levels by means of a weir or flume installed in the discharge with a flowmeter. The flow from the various strata can channel. For such flow measurements, appropriate be obtained by taking the difference in flow at adja-consideration must be given to the pipe or channel hy- cent measuring levels; the flow-meter, equipped with a draulics in the vicinity of the flow-measuring device. centering device, is placed in the well before the pump Formulas, graphs, and tables for measuring flow from is installed. Typical data obtained from such well-flow a test well are given in appendix G. measurements in a test well are shown in figure C-4.
(2) In thick aquifers, or in deposits where the These data can be used to compute the coefficient of material varies with depth, it may be desirable to de- permeability of the various strata tested as shown. The U.S. Army Corps of Engineers Figure C-4. Coefficient of permeability kh of various strata determined from a pumping test and flow measurements in the well screen.
C-4
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 correlation between D10 and kh shown in figure C-4 charge should include the exact time that the observa-was based on laboratory sieve analyses and on such tion was made.
well-flow tests. (3) As changes in barometric pressure may cause
- d. General test procedures. the water level in test wells to fluctuate, the baromet-(1) Before a pump test is started, the test well ric pressure should be recorded during the test.
should be pumped for a brief period to ensure that the (4) When a pumping test is started, changes in pumping equipment and measuring devices are func- water levels occur rapidly, and readings should be tioning properly and to determine the approximate taken as often as practicable for certain selected pie-valve and power settings for the test. The water level zometers (e.g., t = 2, 5, 8, 10, 15, 20, 30, 45, and 60 in the well and all observation piezometers should be minutes) after which the period between observations observed for at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to the test to deter- may be increased. Sufficient readings should be taken mine the initial groundwater table. If the groundwater to define accurately a curve of water level or draw-prior to the test is not stable, observations should be down versus (log) elapsed pumping time. After pump-continued until the rate of change is clearly estab- ing has stopped, the rate of groundwater-level recov-lished; these data should be used to adjust the actual ery should be observed. Frequently, such data are im-test drawdown data to an approximate equilibrium portant in evaluating the performance and charac-condition for analysis. Pumping of any wells in the teristics of an aquifer.
vicinity of the test well, which may influence the test C-3. Equilibrium pumping test.
results, should be regulated to discharge at a constant, uninterrupted rate prior to and during the complete a. In an equilibrium type of pumping test, the well test. is pumped at a constant rate until the drawdown in the (2) Drawdown observations in the test well itself well and piezometers becomes stable.
are generally less reliable than those in the piezom- b. A typical time-drawdown curve for a piezometer eters because of pump vibrations and momentary near a test well is plotted to an arithmetical scale in variations in the pumping rate that cause fluctuations figure C-5 and to a semilog scale in figure C-6. (The in the water surface within the well. A sounding tube computations in fig C-6 are discussed subsequently.)
with small perforations installed inside the well screen Generally, a time-drawdown curve plotted to a semilog can be used to dampen the fluctuation in the water scale becomes straight after the first few minutes of level and improve the accuracy of well soundings. All pumping. If true equilibrium conditions are estab-observations of the groundwater level and pump dis- lished, the drawdown curve will become horizontal.
(Courtesy of UOP Johnson Division)
Figure C-5. Drawdown in an observation well versus pumping time (arithmetical scale).
C-5
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Courtesy of UOP Johnson Division)
Figure C-6. Drawdown in an observation well versus pumping time (semilog scale).
The drawdown measured in the test well and adjacent d. For flow from a circular source of seepage, the observation wells or piezometers should always be coefficient of permeability k can be computed from the plotted versus (log) time during the test to check the formulas for fully penetrating wells.
performance of the well and aquifer. Although the Artesian Flow.
example presented in figure C-6 shows stabilization to have essentially occurred after 500 minutes, it is con- Qw = (C-1) sidered good practice to pump artesian wells for 12 to ln(R/r) 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and to pump test wells where gravity flow Gravity Flow.
conditions exist for 2 or 3 days.
- c. The drawdown in an artesian aquifer as measured Qw = (C-2) ln(R/r) by piezometers on a radial line from a test well is plot- where ted versus (log) distance from the test well in figure Qw = flow from the well C-7. In a homogeneous, isotropic aquifer with artesian D = aquifer thickness flow, the drawdown (H-h) versus (log) distance from H = initial height of groundwa-the test well will plot as a straight line when the flow ter table (GWT) in the aquifer has stabilized. The drawdown H2-h2 h = height of GWT at r versus (log) distance will also plot as a straight line for (H-h) or (H2-h2) = drawdown at distance r gravity flow. However, the drawdown in the well may from well be somewhat greater than would be indicated by a pro- R = radius of influence jection of this straight line to the well because of well entrance losses and the effect of a free flow surface An example of the determination of R and k from an at gravity wells. Extension of the drawdown versus equilibrium pumping test is shown in figure C-7.
(log) distance line to zero drawdown indicates the e. For combined artesian-gravity flow, seepage from effective source of seepage or radius of influence R, be- a line source and a partially penetrating well, the coef-yond which no drawdown would be produced by pump- ficient of permeability can be computed from well-flow ing the test well (fig. C-7). formulas presented in chapter 4.
C-6
TM 5-818-5/AFM 88-5. Chap 6/NAVFAC P-418 (Courtesy of UOP Johnson Division)
Figure C-7. Drawdown versus distance from test well.
C-4. Nonequilibrium pumping test. flow can be expressed as
- a. Constant discharge tests. The coefficients of H-h = (C-3)
T transmissibility T, permeability k, and storage S of a where homogeneous, isotropic aquifier of infinite extent with H - h = drawdown at observation peizometer, feet no recharge can be determined from a nonequilibrium well discharge, gallons per minute type of pumping test. Average values of S and T in the W(u) = exponential integral termed a well func-vicinity of a well can be obtained by measuring the tion (see table C- 1) drawdown with time in one or more piezometers while T = coefficient of transmissibility, gallons per pumping the well at a known constant rate and analyz- day per foot width ing the data according to methods described in (1), (2),
and and (3) below. 1.87r 2S u= (C-4)
(1) Method 1. The formula for nonequilibrium Tt C-7
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 C-8
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 where segment, and record coordinates of matching point r = distance from test well to observation (fig. C-8).
piezometer, feet Step 5. With value of W(u), u, H-h, and r2/t S = coefficient of storage thus determined, compute S and T from equations t = elapsed pumping time in days (C-3) and (C-4).
The formation constants can be obtained approximate- Step 6. T and k from the following equations:
ly from the pumping test data using a graphical meth-od of superposition, which is outlined below. (square feet per minute) (C-5)
Step 1. Plot W(u) versus u on log graph paper, T
known as a type-curve, using table C-1 as in figure k= (feet per minute) (C-6)
C-8. 10,770D Step 2. Plot drawdown (H-h) versus r2/t on log (2) Method 2. This method can be used as an ap-graph paper of same size as the type-curve in figure proximate solution for nonequilibrium flow to a well to C-8. avoid the curve-fitting techniques of method 1 by Step 3. Superimpose observed data curve on using the techniques outlined below, type-curve, keeping coordinates axes of the two curves Step 1. Plot time versus drawdown on semilog parallel, and adjust until a position is found by trial graph as in figure C-9.
whereby most of the plotted data fall on a segment of Step 2. Choose an arbitrary point on time-draw-the type-curve as in figure C-8. down curve, and note coordinates t and H-h.
Step 4. Select an arbitrary point on coincident Step 3. Draw a tangent to the time-drawdown (From Ground Water Hydrology by D. K. Todd, 1959, Wiley & Sons, Inc.
Used with permission of Wiley & Sons, Inc.)
Figure C-8. Method 1 (Superposition) for solution of the nonequilibrium equation.
C-9
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Ground Water Hydrology by D. K. Todd, 1959, Wiley & Sons, Inc. Used with permission of Wiley & Sons, Inc.)
Figure C-9. Method 2 for solution of the nonequilibrium equation.
drawdown in feet per log cycle of time.
mine corresponding W(u) and u from figure C-10.
Step 5. Determine the formation constants by equations (C-3) and (C-4).
(3) Method 3. This method can be used as an ap-proximate solution for nonequilibrium flow to a well if the time-drawdown curve plotted to a semilog scale be-comes a straight line (fig. C-6). The formation con-stants (T and S) can be computed from (C-7) and (From Ground Water Hydrology by D. K. Todd, 1959, Wiley & Sons. Inc.
Used with permission of Wiley & Sons, Inc.)
(C-8)
Figure C-10. Relation among F(u), W(u), and u.
C-10
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 where Step 2. Compute S from equation (C-4) for vari-As= drawdown in feet per cycle of (log) time- ous elapsed pumping times during the test period, and drawdown curve plot S versus (log) t.
to = time at zero drawdown in days Step 3. Extrapolate the S versus (log) t curve to An example of the use of this method of analysis in de- an ultimate value for S.
termining values of T, S, and k is given in figure C-6, Step 4. Compute u from equation (C-4), using using the nonequilibrium portion of the time-draw- the extrapolated S, the originally computed T, and down curve. the original value of r2/t.
(4) Gravity flow. Although the equations for non- Step 5. Recompute T from equation (C-3) using equilibrium pumping tests are derived for artesian a W(u) corresponding to the computed value of u.
flow; they may be applied to gravity flow if the draw- (5) Recharge: Time-drawdown curves of a test down is small with respect to the saturated thickness well are significantly affected by recharge or depletion of the aquifer and is equal to the specific yield of the of the aquifer, as shown in figure C-11. Where re-dewatered portion of the aquifer plus the yield caused charge does not occur, and all water is pumped from by compression of the saturated portion of the aquifer storage, the H versus (log) t curve would resemble as a result of lowering the groundwater. The procedure curve a. Where the zone of influence intercepts a for computing T and S for nonequilibrium gravity source of seepage, the H versus (log) t curve would re-flow conditions is outlined below. semble curve b. There may be geological and recharge Step 1. Compute T from equation (C-3). conditions where there is some recharge but not U.S. Army Corps of Engineers Figure C-11. Time-drawdown curves for various conditions of recharge.
C-11
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 enough to equal the rate of well flow (e.g., curve c). In creased and the above-described procedure repeated many areas, formation boundary conditions exist that until the well has been pumped at three or four rates.
limit the area1 extent of aquifers. The effect of such a The drawdown from each step should be plotted as a boundary on an H versus (log) t graph is in reverse to continuous time-drawdown curve as illustrated in fig-the effect of recharge. Thus, when an impermeable ure C-12. The straight-line portion of the time-draw-boundary is encountered, the slope of the H versus down curves is extended as shown by the dashed lines (log) t curve steepens as illustrated by curve d. It in figure C-12, and the incremental drawdown AH should be noted that a nonequilibrium analysis of a for each step is determined as the difference between pumping test is valid only for the first segment of a the plotted and extended curves at an equal time after time-drawdown curve. each step in pumping. The drawdown H for each step is the sum of the preceding incremental drawdowns
- b. Step-drawdown pump test. and can be plotted versus the pumping rate as shown in (1) The efficiency of a well with respect to en- figure C-13. If the flow is entirely laminar, the draw-trance losses and friction losses can be determined down (H-h for artesian flow and H2-h2 for gravity from a step-drawdown pumping test, in which the well flow) versus pumping rate will plot as a straight line; if is pumped at a constant rate of flow until either the any of the flow is turbulent, the plot will be curved.
drawdown becomes stabilized or a straight-line rela- (2) The well-entrance loss He, consisting of fric-tion of the time-drawdown curve plotted to a semilog tion losses at the aquifer and filter interface through scale is established. Then, the rate of pumping is in- the filter and through the well screen, can be deter-U.S. Army Corps of Engineers Figure C-12. Drawdown versus elapsed pumping time for a step-drawdown test.
C-12
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U.S. Army Corps of Engineers Figure C-13. Drawdown versus pumping rate for a step-drawdown test.
mined from the drawdown versus distance plots for a c. Recovery test.
step-drawdown pump test as illustrated in figure (1) A recovery test may be made at the conclusion C-14. The difference in drawdown between the ex- of a pumping test to provide a check of the pumping tended drawdown-distance curve and the water eleva- test results and to verify recharge and aquifer boun-tion measured in the well represents the well-entrance dary conditions assumed in the analysis of the pump-loss and can be plotted versus the pumping rate as ing test data. A recovery test is valid only if the pump-shown in figure C-15. Curvature of the Hw versus QW ing test has been conducted at a constant rate of dis-line indicates that some of the entrance head loss is the charge. A recovery test made after a step-drawdown result of turbulent flow into or in the well. test cannot be analyzed.
U. S. Army Corps of Engineers Figure C-14. Drawdown versus distance for a step-drawdown test for determining well-entrance loss.
C-13
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 U. S. Army Corps of Engineers Figure C-15. Well-entrance loss versus pumping rate for a step-drawdown test.
(2) When the pump is turned off, the recovery of ratio of log t'/t", where t is the total elapsed time the groundwater levels is observed in the same manner since the start of pumping, and t" is the elapsed time as when the pump was turned on, as shown in figure since the pump was stopped (fig. C-17). This plot C-16. The residual drawdown H is plotted versus the should be a straight line and should intersect the zero (Courtesy of UOP Johnson Division)
Figure C-16. Typical drawdown and recovery curves for a well pumped and then allowed to rebound.
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Courtesy of UOP Johnson Division)
Figure C-17. Residual drawdown versus t/t (time during recovery period increased toward the left).
residual drawdown at a ratio of t'/t" = 1 if there is (C-9) normal recovery, as well as no recharge and no discon-tinuities in the aquifer within the zone of drawdown. where As = residual drawdown in feet per cycle of The ratio t'/t" approaches one as the length of the re- (log) t'/t" versus residual drawdown curve. Displace-covery period is extended. ment of the residual drawdown versus (log) ratio t'/t" (3) The transmissibility of the aquifer can be cal- curve, as shown in figure C-18, indicates a variance culated from the equation with the assumed conditions.
(Courtesy of UOP Johnson Division)
Figure C-18. Displacement of residual drawdown curve when aquifer conditions vary from theoretical conditions.
C-15
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 APPENDIX D EXAMPLES OF DESIGN OF DEWATERING AND PRESSURE RELIEF SYSTEMS This appendix consists of figures D- 1 through D-10, which follow.
D-1
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure D-1. Open excavation; two-stage wellpoint system; gravity flow.
D-2
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw- Hill Book Company.)
Figure D-2. Open excavation; deep wells; gravity flow.
D-3
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure D-3. Open excavation; artesian flow; pressure relief design by flow net.
D-4
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U. S. Army Corps of Engineers Figure D-4. Open excavation; combined deep-well and wellpoint system; gravity flow.
D-5
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure D-5. Open excavation; pressure relief combined with sand drains; artesian and gravity flows.
D-6
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure D-6. Trench excavation; pressure relief by wellpoints; artesian flow.
D-7
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (Modified from Foundation Engineering, G. A. Leonards, ed., 1962, McGraw-Hill Book Company. Used with permission of McGraw-Hill Book Company.)
Figure D-7. Rectangular excavation; pressure relief by deep wells; artesian flow, D-8
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 U. S. Army Corps of Engineers Figure D-8. Shaft excavation; artesian and gravity flows through stratified foundation; deep-well vacuum system.
D-9
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U. S. Army Corps of Engineers Figure D-9. Tunnel dewatering; gravity flows; deep-well system.
D-10
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 PROBLEM: Determine sump and pump capacity to control surface water in an excava-tion, 4 acres in area, located in Little Rock, Ark., for a rainstorm frequency of 1 in 5 years and assuming c = 0.9. Assume all runoff to one sump in bottom of excava-tion.
SOLUTION:
V R = cRA FROM FIGURE:
Rainstorm, min R, in. 3 V R - (x 10 g a l )
10 0.85 83 30 1.70 166 60 2.10 205 Assume sump pump capacity = 4000 gpm. From plot, required storage = 50,000 gal.
U. S. Army Corps of Engineers Figure D-10. Sump and pump capacity for surface runoff to an excavation.
D-11
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 APPENDIX E TRANSFORMATION OF ANISOTROPIC SOIL CONDITIONS TO ISOTROPIC SOIL CONDITIONS E-1. General. All of the analytical methods for mine the required length of well screen W to achieve computing seepage through a permeable deposit are based on the assumption that the permeability of the following procedure can be used. This method is used deposit is isotropic. However, natural soil deposits are in analyses to determine penetration depths needed to stratified to some degree, and the average permeabil- obtain required discharge from partially penetrating ity parallel to the planes of stratification is greater wells or wellpoints. Each stratum of the previous foun-than the permeability perpendicular to these planes. dation or aquifer with thickness d and horizontal and Thus, the soil deposit actually possesses anisotropic vertical permeability coefficients kh and kv, respective-permeability, with the permeability in the horizontal ly, is first transformed using equation (E-1) into an direction usually the greatest. To construct a flow net or make a mathematical analysis of the seepage through an anisotropic deposit, the dimensions of the deposit and the problem must be transformed so that the permeability is isotropic. Each permeable stratum The transformed coefficient of permeability of each of the deposit must be separately transformed into iso- stratum from equation (E-2) is tropic conditions. If the seepage flows through more than one stratum (isotropically transformed), the The thickness of the equivalent homogeneous isotropic analysis can be made by a flow net constructed to ac- aquifer is count for permeability of the various strata.
E-2. Anisotropic stratum. A homogeneous, (E-3) anisotropic stratum can be transformed into an iso- m=1 tropic stratum in accordance with the following equa- where n equals the number of strata in the aquifer.
tion: The effective permeability of the transformed aquifer is (E-1) m-n where E-4 y = actual vertical dimension where n equals the number of strata in the aquifer.
kh = permeability in the horizontal direction The effective well-screen penetration into the trans-k v = permeability in the vertical direction formed aquifer is The horizontal dimensions of the problem would re-main unchanged in this transformation. The permea-bility of the transformed stratum, to be used in all equations for flow or drawdown, is as follows:
(E-2) bility.
E-3. Effective well penetration. In a strati-fied aquifer, the effective well penetration usually dif-fers from that computed from the ratio of the length of well screen to total thickness of aquifer. To deter-E-1
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 APPENDIX F WELL AND TOTAL DISCHARGE MEASUREMENTS F-1. General. The simplest method for determin- b. Orifices.
ing the flow from a pump is to measure the volume of (1) The flow from a pipe under pressure can be the discharge during a known period of time by collect- conveniently measured by installation of an orifice on ing the water in a container of known size. However, the end of the pipe (fig. F-2), or by insertion of an ori-this method is practical only for pumps of small capac- fice plate between two flanges in the pipe (fig. F-3).
ity; other techniques must be used to measure larger The pressure tap back of the orifice should be drilled at flows. right angles to the inside of the pipe and should be per-fectly smooth as illustrated in figure F-4. A rubber F-2. Pipe-flow measurements. tube and glass or plastic pipe may be used to measure
- a. Venturi meter. The flow from a dewatering sys- the pressure head. The diameter of the orifice plate tem can be accurately measured by means of a venturi should be accurate to 0.01 inch; the edge of the plate meter installed in the discharge line. In order to obtain should be square and sharp, should have a thickness of accurate measurements, the meter should be located 1
/8 inch, and should be chamfered at 45 degrees as about 10 pipe diameters from any elbow or fitting, and shown in figure F-2. The approach pipe must be the pipe must be flowing full of water. The flow smooth, straight, and horizontal; it must flow full, and through a venturi meter can be computed from the orifice should be located at least eight pipe diam-eters from any valves or fittings. The flow for various sized cap orifice-pipe combinations can be obtained from figure F-5.
(2) The flow through an orifice in a pipe can be computed from The pressures h1 and h2 may be taken as illustrated in figure F-1 for low pressures, or by a differential mer-cury manometer for high pressures. Gages may be used but will be less accurate.
(Courtesy of Fairbanks Morse. Inc., Pump Division) (Courtesy of Fairbanks Morse. Inc., Pump Division)
Figure F-1. Venturi meter. Figure F-2. Pipe cap orifice.
F-1
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 1
d 2/ d1 C 0.25 0.604 1.002 0.30 0.605 1.004 0.35 0.606 1.006 0.40 0.606 1.013 0.50 0.607 1.033 0.60 0.608 1.072 0.70 0.611 1.146 0.80 0.643 1.301 0.90 0.710 1.706 (Courtesy of Fairbanks Morse, Inc., Pump Division)
Note: The diameter of the orifice should never be larger than 80 percent of the pipe diameter in order to obtain a satisfactory pres-Figure F-3. Orifice in pipe. sure reading.
- c. Pitot tube. The flow in a pipe flowing full can also be determined by measuring the velocity at different locations in the pipe with a pitot tube and differential manometer, and computing the flow. The velocity at any given point can be computed from (F-3) where V = velocity C = meter coefficient g = acceleration of gravity h = velocity head The flow is equal to the area of the pipe A times the (Courtesy of Fairbanks Morse, Inc., Pump Division) average velocity V, or Q = AV (F-3a)
Figure F-4. Approvedpressure taps.
(Courtesy of Fairbanks Morse, Inc., Pump Division)
Figure F-5. Pipe cap orifice chart.
F-2
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 thickness and freeboard must be subtracted from the measured y to obtain the correct value of y.
- b. Fountain flow. The flow from a vertical pipe can be approximated by measuring the height of the use of and the stream of water above the top of the pipe (fig.
v = velocity at center of concentric rings of equal F-8). Two types of flow must be recognized when deal-area ing with fountain flow. At low crest heights, the dis-n = number of concentric rings charge has the character of weir flow, while at high F-3. Approximate measurement meth- crest heights the discharge has the character of jet ods. flow. Intermediate values result in erratic flow with respect to the height of the crest H.
- a. Jet flow. Flow from a pipe can be determined ap- (1) Where the flow exhibits jet character, it can be proximately by measuring a point on the arc of the computed from stream of water emerging from the pipe (fig. F-6),
using the following equation: (F-5) where (F-4) Q = flow, gallons, per minute where K = constant varying from 0.87 to 0.97 for pipes 2 to 6 inches in diameter and h = 6 to 24 inches Q = flow, gallons per minute D = inside pipe diameter, inches A = area of stream of water at end of pipe in H = vertical height of water jet, inches square inches. If the pipe is not flowing full, Where the flow exhibits weir character, it can be ap-the value of A is the cross-sectional area of the proximated by using the Francis Formula, Q = 3.33 water jet where it emerges from the pipe, The Bh3/2, with B being the circumference of the pipe.
area of the stream can be obtained by multi- (2) Some values of fountain flow for various nom-plying the area of the pipe times the Effective inal pipe sizes and heights of crest are given in table Area Factor (EAF) in figure F-7 using the F-1.
ratio of the freeboard to the inside diameter of the pipe. F-4. Open channel flows.
x = distance along axis of the discharge pipe a. Weirs. Flow in open channels can be measured by through which the stream of water moves weirs constructed in the channel. Certain dimensional from the end of the pipe to a point(s), inches relations should be recognized in constructing a weir y = distance perpendicular to the axis of the dis- to obtain the most accurate flow measurements as charge pipe through which the stream of shown in figure F-9. The weir plate should be a non-water drops, measured from the top or surface corrosive metal about 1/4 inch thick with the crest 1/8 of the stream of water to point(s), inches inch wide, and the downstream portion of the plate It should be noted that the x and y distances are meas- beveled at 45 degrees. The crest should be smooth, and ured from the top of the stream of water; if y is meas- the plate should be mounted in a vertical plane perpen-ured in the field from the top of the pipe, the pipe dicular to the flow. The channel walls should be U. S. Army Corps of Engineers Figure F-6. Flow from pipe.
F-3
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC p-418 U. S. Army Corps of Engineers Figure F-7. Effective area factor for partially filled pipe.
Table F-1. Flow (gallons per minute) from Vertical Pipes Height of Crest H Nominal Diameter of Pipe, inches inches 2 3 4 5 6 8 l-1/2 22 43 68 85 110 160 2 26 55 93 120 160 230 3 33 74 130 185 250 385 4 38 88 155 230 320 520 5 44 99 175 270 380 630 6 48 110 190 300 430 730 8 56 125 225 360 510 900 10 62 140 255 400 580 1050 12 69 160 280 440 640 1150 15 78 175 315 500 700 1300 18 85 195 350 540 780 1400 21 93 210 380 595 850 1550 24 100 230 400 640 920 1650 U. S. Army Corps of Engineers F-4
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 U. S. Army Corps of Engineers Figure F-8. Fountain flow measurement.
Courtesy of Fairbanks Morse, Inc., Pump Division Figure F-11. Plan and elevation of the Parshall measuring flume.
smooth and parallel, and extend throughout the region of flow associated with the weir. Complete aeration of the nappe is required for rectangular suppressed weirs. The approach channel should be of uniform sec-tion and of a length at least 15 times the maximum head on the weir. Smooth flow to and over the weir is essential to determination of accurate rates of flow.
The head on the weir should be measured with a hook gage located in a stilling box at the side of the ap-(Courtesy of Fairbanks Morse. Inc., Pump Division) proach channel. The communication pipe to the still-ing box should be about 11/2 inches in diameter and Figure F-9. Rectangular suppressed weir. should be flush with the side of the channel. Formulas for calculating the flow over various types of weirs are shown in figure F-10.
- b. Parshall flume. Flow in an open channel may also be measured with a Parshall flume (fig. F-11). The head drop through the flume is measured by two gates (fig. F-11); but if the depth of water at the lower gage is less than 70 percent of the depth at the upper gage, the flow is termed free and the discharge can be de-termined by reading the upstream hook gage alone.
The construction and dimensions of a Parshall flume are shown in figure F-11 and table F-2. The free flow discharge of a Parshall flume is given in table F-3.
(Courtesy of Fairbanks Morse, Inc., Pump Division)
Figure F-10. Formulas for computing flow over various types of weirs.
F-5
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 F-6
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 APPENDIX G EXAMPLES OF DETAILED DEWATERING SPECIFICATIONS G-1. General. This appendix provides examples ample time and knowledge to check the Contractors based on actual specifications for installation of de- submittals; and a willingness to reject the Contractors watering or pressure relief systems, extracted from proposals and accept any associated delays in starting Government and private industry contract documents. the project until an acceptable design is submitted.
They have been selected and presented to illustrate the d. For large and complex dewatering projects where various types of specifications described in the test dewatering is critical to the safety of the work, type (para 7-2). B-l specifications are recommended; types A-2 and B-3 may be suitable if the Owner or Engineer can or G-2. Types of specifications. will enforce the provisions relating to approval of de-
- a. Type A specifications are projects where the de- sign, installation, and operation.
watering is not too critical with respect to damage to the permanent work or safety to personnel, and only G-3. Example of type A-1 specifications the desired results are to be specified. This type of (dewatering).
specifications makes the Contractor completely re- a. General. The Contractor shall provide all de-sponsible for design, installation, and operation of the watering necessary to keep the construction and work system(s). Specifications may be brief (type A-1) or areas dry. The Contractor shall design, install, oper-more detailed (type A-2), depending upon complexity ate, and maintain an adequate system. The system and criticality of the dewatering or pressure relief sys- shall be of sufficient size and capacity to maintain a tem. The examples of these two types are from Corps dry condition without delays to construction opera-of Engineers projects. tions.
- b. Type B specifications are recommended for large, b. Submittals. The Contractor shall submit a pro-complex systems, or where the dewatering or pressure posed dewatering plan for approval of the Contracting relief is critical with regard to construction of the proj- Officer prior to initiation of any construction or exca-ect, damage to permanent work, and safety. vation operations. The plan shall show all facilities (1) Type B-1. A specification that gives a detailed proposed for complying with this section.
design and requirements for installation of a mini- c. Payments. Payment for all work covered in this mum system but makes the Contractor responsible specification will be made at the contract lump sum for operating and maintaining the system, supple- price for dewatering, which price shall constitute menting it as necessary to obtain the required results. full compensation for furnishing all plant, equipment, The installation is then checked with a full-scale labor, and materials to install, operate, maintain, and pumping test to verify its adequacy. remove the dewatering system.
(2) Type B-2. A specification that gives a detailed design and installation procedure but makes the Con- G-4. Example of type A-2 specifications tractor responsible only for normal repairs and opera- (dewatering).
tions. The Government or Owner thus assumes the re- a. Scope. This section covers the design, furnishing, sponsibility for the adequacy of the system and its installation, operation, maintenance, and removal of a components, major repairs, and replacement of equip- dewatering system, complete.
ment if necessary. b. Dewatering.
(3) Type B-3. A specification that is similar to (1) General. The dewatering system shall be of a type A, wherein only the desired results are specified, sufficient size and capacity as required to control except the degree of difficulty or criticality of the sys- hydrostatic pressure on all clay strata below elevation tem requires that the Contractor retain an Expert in - 13.0 feet to depths indicated by the logs of borings, the field of dewatering or pressure relief systems to de- to permit dewatering of the area specified in para-sign, supervise installation, and monitor the system. graph d below, and to allow all material to be exca-
- c. Types A-1 and B-3 specifications should not be vated, piles driven, and concrete placed, all in a dry used unless the issuing agency has considerable confi- condition. The system shall include a deep-well sys-dence in the (dewatering) qualification of the bidders; tem, a wellpoint system, other equipment, appurte-G-1
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 nances, and related earthwork necessary for the re- operation, maintenance, and any failure of any compo-quired control of water. The sequence of installation of nent of the system.
components of the dewatering system shall be in ac-
- d. Dewatering system.
cordance with the specifications and drawings. The system shall remain in continuous operation, as speci- (1) Deep-well system. The clay and sand strata be-fied, until a written directive to cease dewatering oper- low elevation - 13.0 feet are continuous over a large area. Removal of soils above elevation - 25.0 feet. A ations has been received from the Contracting Officer.
(2) Control of water. The Contractor shall control, deep-well system shall be provided to relieve this pres-by acceptable means, all water regardless of source. sure. The pressure shall be relieved in the sand strata Water shall be controlled and its disposal provided for such as those indicated on boring S-II-SS-1-62(A) at each berm. The entire periphery of the excavation from 67.5 to 72.0 feet and from 85.5 to 142.5 feet.
area shall be ditched and diked to prevent water from These strata will vary in elevation and thickness over entering the excavation. The Contractor shall be fully the area. The deep-well system shall be of sufficient responsible for disposal of the water and shall provide capacity to lower the hydrostatic head to elevation all necessary means at no additional cost to the Gov- -40.0 feet as measured in observation wells at nine ernment. points in the excavation. One installed spare deep well, complete and ready for immediate operation, shall be
- c. Design. The dewatering system shall be designed provided for each two operating wells. The use of gaso-using accepted and professional methods of design and line prime movers will not be permitted in the opera-engineering consistent with the best modern practice. tion of deep wells. At each of the nine points two ob-The dewatering system shall include the deep wells, servation wells shall be installed. One observation well wellpoints, and other equipment, appurtenances, and shall be installed with the screen in the upper sands, related earthwork necessary to perform the function. and one observation well shall be installed with the A representative of the Contractor shall visit the site screen in the lower sands. The riser pipe for the obser-to determine the conditions thereof. The Contractor vation wells will be 2-inch pipe in 5-foot sections. One shall be responsible for the accuracy of the drawings of the observation points shall be constructed at co-and design data required hereinafter. ordinate N254 460, E260 065. The remainder of the (1) Drawings and design data. The Contractor observation points will be located by the Contracting shall submit for the approval of the Contracting Of- Officer after the dewatering plan is submitted. The ex-ficer, within 30 calendar days after receipt of Notice to act tip elevation of all observation wells will be estab-Proceed, drawings and complete design data showing lished after the dewatering plan is submitted; how-methods and equipment he or she proposes to utilize in ever, the tip elevation in the lower sand will be at least dewatering, including relief of hydrostatic head, and 100 feet below original ground surface, and the tip ele-in maintaining the excavation in a dewatered and in a vation of the observation wells in the upper sands will hydrostatically relieved condition. The material to be be approximately 70 feet below original ground sur-submitted shall include, but not necessarily be limited face. The Contractor shall maintain the observation to, the following: wells and keep daily records of readings until other-(a) Drawings indicating the location and size of wise directed by the Contracting Officer.
berms, dikes, ditches, all deep wells, observation wells, (2) Wellpoint system. A wellpoint system shall be wellpoints, sumps, and discharge lines, including their used above the top of clay shown on the borings at ap-relation to water disposal ditches. proximate elevation - 14.0 feet but to dewater the (b) Capacities of pumps, prime movers, and area from original ground surface to the top of the standby equipment. clay. This system shall have sufficient capacity to low-(b) Design calculations proving adequacy of sys- er the head within the excavation to the top of the tem and selected equipment. clay.
(d) Detailed description of dewatering proce-dure and maintenance method. e. Available soil test data and pumping test data.
(2) Responsibility. Approval by the Contracting The soil test data obtained by the Government are Officer of the plans and data submitted by the Con- shown on the boring logs. Additional laboratory data tractor shall not in any way be considered to relieve and samples of the soils from borings shown in the the Contractor from full responsibility for errors plans are available in the District office for inspection therein or from the entire responsibility for complete by bidders. Typical permeability data from laboratory and adequate design and performance of the system in tests at this site are tabulated. Pumping tests have not controlling the water level in the excavated area and been made at the site; however, the soil profile at the for control of the hydrostatic pressures to the depths B-1 and B-2 test stand excavation is similar to this hereinbefore specified. The Contractor shall be solely site and this excavation is now being dewatered by a responsible for proper design, installation, proper deep-well system. Data on this system can be inspected G-2
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 at the office of the Area Engineer or in the District of- Officer, the Contractor shall remove all dewatering fice. equipment from the site, including related temporary
- f. Standby equipment. The Contractor shall furnish electrical secondary as approved by the Contracting standby pumping equipment power as follows: Officer. All wells shall be plugged and/or filled. Re-(1) Diesel, liquid petroleum gas, and gasoline moval work required under this paragraph does not in-fueled prime movers for pumps shall have 50 percent clude any of site cleanup work as required elsewhere in standby equipment. these specifications.
(2) Portable electric generators shall have 100 j. Method of measurement. Dewatering, as specified percent standby generating equipment. in K(2) below, to be paid for will be determined by the (3) Commercial electric power, which is available number of calendar days (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />), counted on a day-at the site, shall have 100 percent standby electric gen- to-day basis, the excavation is maintained in a de-erating equipment. watered condition, measured to the nearest hour, from (4) The Contractor shall provide not less than one completion and final acceptance of the concrete foun-complete spare pumping unit for every five pumping dation for the A- 1 test stand area to the date on which units other than deep-well pumps in the system. In no a written directive to cease pumping operations is re-case shall less than one standby pumping unit be pro- ceived from the Contracting Officer.
vided. The sizes of the standby pumping units shall be k. Payment.
subject to the approval of the Contracting Officer. (1) Dewatering during excavation and construc-
- g. Damages. The Contractor shall be responsible tion. Payment for furnishing all designs and engineer-for, and shall repair without cost to the Government, ing data, plant, labor, equipment, material, and appur-any damage to work in place, the other Contractors tenances and for performing all operations in connec-equipment, and the excavation, including damage to tion with designing, furnishing, installing, operating, the bottom due to heave and including removal of ma- and maintaining the dewatering system until the work terial and pumping out of the excavated area that may in the area is completed and accepted will be made at result from his or her negligence, inadequate or im- the applicable contract lump sum price for Dewater-proper design and operation of the dewatering system, ing A-1 Test Stand Area, Deep Wells, and Dewater-and any mechanical or electrical failure of the de- ing A-1 Test Stand Area, Except for Deep Wells.
watering system. Twenty-five percent of the contract price for each item will be paid upon completion of the installation of the
- h. Maintaining excavation in dewatered condition. dewatering system for the excavation. A second 25 (1) General. Subsequent to completion and accept- percent of the contract price for each item will be paid ance of all work, including piling and concrete work, in upon satisfactory completion of 80 percent of the esti-the excavated area, the Contractor shall maintain the mated excavation quantity. A third 25 percent of the excavation in a dewatered condition and the water contract price for each item will be paid upon satisfac-level in the observation wells at the specified and ap- tory completion of 100 percent of the required excava-proved elevation until such time as the succeeding tion. Fifteen percent of the contract price for each Contractor commences dewatering operations, and a item will be paid when final acceptance of all work in written directive to cease pumping operations has the excavation is made. The remaining 10 percent of been received from the Contracting Officer. System the contract price for each item will be paid after writ-maintenance shall include but not be limited to 24- ten notice to cease dewatering operations has been is-hour supervision by personnel skilled in the operation, sued and final cleanup and final acceptance of all work maintenance, and replacement of system components; has been made.
standby and spare equipment of the same capacity and (2) Maintaining area in dewatered condition. Pay-quantity as specified in f above; and any other work re- ment for furnishing all plant, labor, equipment, and quired by the Contracting Officer to maintain the ex- material and for performing all operations in connec-cavation in a dewatered condition. Dewatering shall be tion with maintaining the accepted excavations in a a continuous operation and interruptions due to out- dewatered condition will be made at the applicable ages, or any other reason, shall not be permitted. contract unit price per calendar day for Maintaining (2) Responsibility. The Contractor shall be respon- A-1 Test Stand Excavation in Dewatered Condition.
sible for all damages to accepted work in the excava- No payment will be made for this item for periods, tion area and for damages to any other area caused by measured to nearest hour, during which the dewater-his or her failure to maintain and operate the system ing system is not operated and maintained as specified as specified above or from water overflowing his or her hereinbefore.
ditch. (3) Removal of systems. Payment for furnishing
- i. System removal. Upon receipt of written directive all plant, labor, equipment, and material and for per-to cease dewatering operations from the Contracting forming all operations in connection with removal of G-3
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 the dewatering system will be made at the applicable daily supervision by someone skilled in the operation, contract lump sum price for Removal of A-l Test maintenance, and replacement of system components; Stand Dewatering System. However, if the Contrac- at least one spare submersible pump and controls and tor so elects to sell the installed and operating system one pressure pump of the same capacity as specified; to the succeeding Contractor or to dispose of the sys- and any other work required by the Contracting Offi-tem in place by other means, as approved by the Con- cer to maintain the excavation in a dewatered and tracting Officer, the Contractor shall be relieved from hydrostatically relieved condition. Dewatering and the requirements of the specified removal work and no pressure relief shall be a continuous operation and in-payment will be made for this item. terruptions due to power outages, or any other reason, shall not be permitted. Some responsible person shall G-5. Example of type B-1 specifications also monitor the dewatering sump pumping, and (dewatering and pressure relief). pumping the relief wells continuously until the suc-
- a. Scope. This section covers furnishing, installa- ceeding contractor assumes the responsibility for such, tion, operation, maintenance, and removal of the jet- and the Contractor has received a written instructive eductor wellpoint and pressure relief well systems, as that he or she is no longer responsible for this oper-subsequently specified in this section; control of any ation.
seepage from the soils above the bottom of the excava- (2) The Contractor shall also be fully responsible tion not intercepted by the jet-eductor wellpoint sys- for any failure of any component of the systems. The tem deemed necessary by the Contractor to permit in- Contractor shall be responsible for all damages to stallation of the sheeting shown to grade as specified; work in the excavation area and for damages to any pumping of surface water or seepage through the other area caused by failure to maintain and operate sheeting during excavation or after the jet-eductor de- the dewatering and pressure relief systems as speci-watering system is turned off or removed; and install- fied.
ing any additional pressure relief wells, pumps, and c. Wellpoint and pressure relief systems.
appurtenances, if necessary, to maintain the hydro- (1) General. The jet-eductor wellpoint system static water level in the clayey silty sand and sandy silt specified is to lower the groundwater table adjacent to (semipervious) stratum (about el 235 +/- 1 foot) beneath the excavation and intercept seepage from the sandy the excavation at all times. and gravelly soil above the Cockfield formation (at
- b. Responsibility. The Contractor shall be fully re- about el 253.0 feet) so that excavation and placement sponsible for furnishing, installing, operating, main- of the wood sheeting and pea gravel backpack can be taining, and removing all wellpoint, pressure relief, accomplished with minimum difficulty, and with little and seepage or surface water control systems. How- if any sloughing of the soil from the cut slope. The ever, any pressure relief wells, pumps, piping, and wellpoint system combined with a sump ditch between electrical wiring and controls required to lower and the sheeting and edge of structural mat when properly maintain the hydrostatic water level in the semiper- installed, maintained, and pumped should permit plac-vious stratum below the bottom of the excavation, oth- ing the mud mat on foundation soils free of any sur-er than the pressure relief system specified, will be face water. If the Contractor considers the spacing of paid for as an extra. the wellpoints inadequate to accomplish the excava-(1) The Contractor shall be responsible for: tion and placement of the wood sheeting, as specified, (a) Installing and testing the wellpoint and pres- he or she should space the wellpoints closer. The well-sure relief systems as specified. point system shall remain in continuous operation un-(b) Dewatering or controlling any seepage from til the excavation has been dug to grade and the mud the soils above the bottom of the excavation so that mat poured. After the mud mat has been placed, the the sheeting may be installed without any significant wellpoint system may be turned off and any seepage sloughing of earth during excavation and placement of through the wood sheeting removed by sump pump-sheeting and pea gravel backpack. ing. After the A piezometers for monitoring the (c) Maintaining the hydrostatic water level in groundwater table above the Cockfield formation and the semipervious stratum below elevation 250.0 feet the wellpoint system have been installed, the system at all times. shall be tested for flow and groundwater lowering pri-(d) Maintaining the bottom of the excavation or to starting any excavation. The well system is to re-free of all seepage or surface water until the structural lieve excess hydrostatic pressure in the semipervious mat has been placed and the waterproofing installed stratum below the excavation to insure no heave of the up to the top of the mat. soil strata above this stratum. It is imperative that no (e) Operating, maintaining, and monitoring the heave of the soil strata above the semipervious stra-wellpoint and pressure relief well systems. System tum occur inasmuch as the building will be founded di-maintenance shall include but not be limited to at least rectly on the foundation soils above this stratum.
G-4
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 (2) Control of water. The Contractor shall control Cockfield formation as encountered during installa-all surface water, any seepage into the excavation, and tion of the system.
hydrostatic pressure in the semipervious stratum be- (b) The wellpoints shall have a minimum screen neath the excavation, regardless of source. Any open- or slotted length of 30 inches and shall be of the bot-ing in the wood lagging, through which seepage is car- tom suction type. The wellpoint screens shall be of 30-rying any soil, shall be promptly caulked. Any water mesh cloth or have #25 slots. The wellpoints shall be of seeping, falling, or running into the excavation as it is a high-capacity type with a diameter of approximately dug shall be promptly pumped out. The entire periph- 21/2 inches. The jet-eductor pumps and pressure and re-ery of the excavation area shall be suitably diked, and turn riser pipes shall have a capacity and be operated the dike maintained, to prevent any surface water at a pressure which will produce a minimum flow of 2 from running into the excavation. The Contractor gallons per minute with a static lift of 25 feet. If the shall be fully responsible for disposal of all water from Contractor uses jet-eductor pumps with a yield capac-the excavation and from the wellpoint and relief well ity greater than 3 gallons per minute, it will be neces-systems in an approved manner at no additional cost sary for him to redesign the pressure and return head-to the Government. er lines. The pressure pumps and recirculation tank (3) Wellpoint and pressure relief system data. The shall be designed by the Contractor. The pumps shall Contractor shall submit for approval by the Contract- have adequate head and pumping characteristics to ing Officer, within 10 calendar days after receipt of match the number and capacity of the jet-eductors be-Notice to Proceed, complete information regarding ing used. Both the pressure and return header lines motor generator, pumps, wellpoints, jet-eductors, well shall be provided with pressure gages at the pumps screens, and any other equipment that he or she pro- and across the excavation from the pumps. Overflow poses to utilize in dewatering and relieving hydrostatic from the recirculation tank shall be arranged so that pressure, and in maintaining the excavation in a dewa- the flow from the wellpoint system can ye readily tered and hydrostatically relieved condition. The data measured.
to be submitted shall include, but not necessarily be (c) The filter sand to be placed around the well-limited to, the following: points and up to within 10 feet of the ground surface shall be a clean, washed sand (A) having a gradation (a) Characteristics of pumps and motor gener-falling within the following range:
ator, and types and pertinent features of well screens, U.S. Standard Filter Sand A wellpoints, and jet-eductor pumps. Sieve Size Percent Passing (b) Plans for operating, maintaining, and moni- 10 78-100 toring the wellpoint and relief well systems. 16 35-82 20 15-58 (4) Jet-eductor wellpoint system. 30 3-32 (a) The soils at the site consist essentially of fill, 40 0-13 clays and silts, and some silty sand and clay sands with 50 0-3 occasionally pea gravel above the Cockfield formation. (d) The wellpoints shall be installed by a combi-The jet-eductor wellpoint system has been designed to nation of driving and jetting (with a hole puncher) a lower the groundwater table and intercept most of the 12-inch sanding casing to approximately 1 foot be-seepage that will flow toward the excavation. Because low the top of the Cockfield formation, rinsing the of the impervious Cockfield formation at about the sanding casing until there is no more sediment in the bottom of the excavation, it is not possible to lower the casing, centering the wellpoint and lowering it to the groundwater table and intercept most of the seepage bottom of the hole, placing Filter Sand A in the casing that will flow toward the excavation as it is dug. Be- around the wellpoint in a heavy continuous stream up cause of the impervious Cockfield formation at about to within 10 feet of the ground surface, and then fill-the bottom of the excavation, it is not possible to lower ing the remainder of the hole with a thick bentonitic the groundwater table completely down to the top of grout or by pouring in a mixture of dry sand contain-this stratum or to intercept all seepage above it. By ing 10 percent granular bentonite, up to the ground proper installation, the jet-eductor wellpoint system surface. Before the working day is over, all wellpoints should intercept most of the seepage and stabilize the installed that day shall be pumped with a small centri-soil sufficiently to install the wood sheeting subse- fugal pump, capable of producing a 25-foot vacuum, quently specified without any significant sloughing of until the effluent becomes clear. Jet water used for in-the soil behind the sheeting prior to placement of the stalling the wellpoints shall be clear polished so that pea gravel backpack. The fact that some minor seepage return of jet water up through the sanding casing is may bypass the wellpoints should be anticipated by achieved before the casing has been driven to a depth the Contractor. The tips for the wellpoints shall be in- of more than about 10 feet from the surface. It may be stalled approximately 12 inches below the top of the necessary or expeditious to prebore the holes for the G-5
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 wellpoints with a 10-inch auger prior to driving and minute at a total dynamic head (TDH) equal to 50 feet.
jetting the 12-inch sanding casing to grade. Any such The Contractor shall be responsible for designing and predrilling should be accomplished in a manner which installing the electrical system for powering the sub-will not cause any caving of the hole as it is drilled. In mersible pumps in the relief wells. The electrical sys-jetting the sanding casing for the wellpoints, provision tem shall meet the local electrical code and be ap-shall be made to prevent jet water from spraying over proved by the Contracting Officer. Each pump shall be sidewalks and streets being used for pedestrians provided with a starter and fuse disconnect with a and/or vehicular traffic, and from running over or into clearly visible red light mounted on the control panel streets being used by such. The Contractor will be re- that shows red when the pump is running. A motor sponsible for disposal of jet water in a manner satisfac- generator with a capacity capable of starting all of the tory to the City and the Construction Manager. submersible pumps in the relief wells at one time shall (e) Each jet-eductor wellpoint shall be provided be provided and hooked into the electrical system at all with a suitable strainer at the top of the pressure riser times. This generator shall be operated to keep the pipe to prevent the entrance of any particles, which pumps in the relief wells running in event of power might clog the jet-eductor nozzle, and a stopcock or failure. It shall be maintained in first class condition, valves, which will permit isolating the wellpoint to protected from the weather, and started at least twice permit pressure testing and pumping the wellpoint a week to check its operating condition.
separately if desired. (c) The bottom of the screens for the relief wells (5) Pressure relief wells and pumps. The pressure shall be installed at or slightly below the bottom of the relief wells shall be installed at the locations specified. semipervious stratum as encountered during installa-These wells are to reduce the hydrostatic head in the tion. They shall be installed using the same procedure semipervious stratum below the excavation to eleva- as specified for the wellpoints except that in all proba-tion 250.0 feet or lower as measured by the B piezome- bility it will be necessary to predrill the holes to grade ters installed in this same stratum at the locations, as with a lo-inch auger because of the difficulty in jetting subsequently specified. through some of the clay strata to be penetrated. After (a) The screens for the relief wells shall be 10 the (12-inch) sanding casing has been driven and jetted feet long and shall be installed in the semipervious to grade, the well screen and riser pipe shall be cen-stratum at about elevation 235 +/- 1 foot. The screens tered accurately and lowered to within 1 foot of the shall have a nominal diameter of 4 inches. They may bottom of the casing. Filter Sand B poured into the be manufactured of slotted Schedule 40 PVC pipe, sanding casing around the well riser pipe in a heavy Johnson wire-wrapped screen, or other approved steady stream until the filter sand is at least 5 feet screen. The screens shall be covered with 30-mesh above the top of the screen; the remainder of the hole brass or stainless steel gauze or slotted with #20 slots may be filled with clean medium sand. The sanding with a minimum open area of 5 percent. The riser pipe casing shall then be immediately pulled. After the well shall also have a 4-inch nominal diameter; it may be has been installed, it shall be promptly pumped with a either PVC plastic pipe or steel. The screen portion of centrifugal pump capable of producing a 25-foot va-the wells and up for a distance of 5 feet above the top cuum until the effluent is clear. The submersible pump of screen shall be surrounded with a clean, washed uni- then shall be lowered and suspended in the well with form filter sand (B) with the following gradation: the intake of the pump at about the top of the well U.S. Standard Filter Sand B screen. The pump or discharge pipe shall be provided Sieve Size Percent Passing with a check valve, and the connection between the 10 95-100 discharge pipe from the pump to header pipe shall be 20 58-90 30 30-73 provided with a gate valve which will permit removal 40 5-50 of the pump if necessary. The top of the well shall be 50 0-25 sealed with a suitable well cap or plate provided with a 70 0-8 hole through which a sounding line may be lowered to Suppliers who can furnish Filter Sands A and B are as determine the water level in the well when testing and follows: monitoring the system. A full-scale pumping test shall Filter Sand Filter Sand be run on the completed system to determine its ade-Supplier A B quacy and pumping rate. This test shall be run for a
- 1. - - - minimum of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. The water level in the B piezome-
- 2. - - - ters and in the wells and flow from the system shall be
- 3. - - -
measured at the following intervals after the start of (b) Pumps for the relief wells shall be submersi- pumping: 10 minutes, 30 minutes, 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, 3 ble pumps suitable for installation in 4-inch nominal hours, 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, and 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
diameter wells with a capacity of 3 to 10 gallons per (d) All of the submersible pumps shall be new, G-6
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 and one new spare pump and controls shall be at the PVC pipe cement. The top of the riser shall be cut off job site at all times. The electrical system and controls 30 inches above the ground surface and provided with shall be designed so that failure of any one pump, or a threaded cap with a /,-inch hole in the side. The up-the need to disconnect and replace a pump, does not per part of the piezometer shall be protected by install-adversely affect operation of any other pump. ing a 6-inch I.D. cardboard casing around the riser em-(e) The Contractor shall be responsible for re- bedded 2 feet below the ground surface and filling the cording the results of the pumping tests on the well casing with concrete. After removal of the cardboard system and furnishing them to the Construction Man- casing, the top 30 inches of each piezometer shall be ager. He shall also advise the Construction Manager at painted day-glo orange, and the piezometer number least three days in advance of making this test so that marked in 3-inch-high black characters.
a representative of the Government can observe the (b) Each piezometer shall be pumped after in-test. stallation and then checked to determine if it is func-(f) Because of the importance of preventing any tioning properly by filling with water and observing significant artesian head in the semipervious stratum the rate of fall. For the piezometer to be considered ac-above the bottom of the excavation, tees shall be in- ceptable it shall pump at a rate of at least 0.5 gallon stalled in the riser pipe for the deep wells to provide per minute, or when the piezometer is filled with wa-relief of this artesian pressure in event of any pump or ter, the water level shall fall approximately half the electrical failure. These tees shall be provided with distance to the groundwater table in a time less than plugs during installation of the wells; as the excava- the time given below for various types of soil:
tion is carried down to each tee, the plug in that tee Type of Soil Period of Approximate time shall be removed and a 2-inch pipe with brass check in which piezometer observation of 50 percent valve inserted in the tee so that water can flow into the screen is wet minutes fall, minutes excavation. As each tee is connected into the excava- Sandy silt (>50% silt) 30 30 tion, the tee above shall be sealed. Silty sand (<50% silt, (g) Installation of the wellpoint and the relief >12% silt) 10 5 Fine sand (<12%silt) 5 1 well systems shall be supervised by someone with at least 5 years actual experience in installing such sys- If the piezometer does not function properly, it shall be tems. A log of each relief well shall be maintained by developed by air surging or pumping with air if neces-the Contractor; forms for logging installation of the sary to make it perform properly.
wells will be furnished by the Contracting Officer. d. Available soil data. Generalized soil profiles and (6) Piezometers. Piezometers shall be installed at logs of boring were made for Government. Samples of the locations specified to measure the groundwater ta- the soils from the borings made by are ble in the line of wellpoints and in the excavation (A available for inspection by bidders at piezometers), and to measure the hydrostatic water e. Damages. The Contractor shall be responsible and level in the semipervious stratum beneath the excava- shall repair any damage to the excavation, including tion (B piezometers). The tips of the A piezometers damage to the bottom due to heave, that may result shall be set at the top of the Cockfield formation; the from his or her negligence, improper operation of the tips of the B piezometers shall be set in the middle of dewatering and pressure relief systems, and any me-the semipervious stratum. The A piezometers shall be chanical or electrical failure of the systems.
surrounded with Filter Sand A; the tips of the B pie-zometers shall be surrounded with Filter Sand B. The f. Maintaining excavation unwatered and pressure A piezometers shall be installed using the same equip- relieved. Subsequent to completion and acceptance of ment and procedure specified for installing the well- all work in the excavated area, the Contractor shall points; the B piezometers shall be sealed with an ex- maintain the excavation unwatered and the water lev-panding cement bentonite grout up to at least eleva- el in the B piezometers at or below elevation 250.0 feet tion 252.0 feet. After sealing around a B piezometer, until placement of the structural mat is complete and the sanding casing shall be checked to see if there is the backfill has been placed to elevation 256.0 feet, any bentonite or cement in the casing; and if such ex- and a written directive to cease pumping has been re-ists, the casing shall be thoroughly washed prior to in- ceived from the Contracting Officer. The Contractor stallation of the next piezometer. shall be responsible for maintaining the excavation un-(a) The piezometers shall consist of a 1.50-inch watered and pressure relieved during this period as set inside diameter (I.D.) (Sch 40 or 80) PVC screen with for above except for operation of the wellpoint system.
0.025- to 0.030-inch slots connected to 1.50-inch I.D. g. Removal of wellpoint system. After excavation to (Sch 40 or 80) PVC riser pipe. Screens shall be 5 feet grade, installation of drainage ditch, sump pump, and long. The joints of the screen and riser shall be flush placement of the mud mat, the wellpoint system may (inside and outside) and shall be glued together with be removed. Removal of the wellpoint dewatering sys-G-7
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 tern shall include pulling all of the wellpoints and re- The contractor shall designate a representative or lated header pipes, pumps, recirculation tank, and engineer experienced in dewatering large excavations temporary electrical secondary, as approved by the whose responsibility will be to assure that the dewater-Contracting Officer. Any holes remaining after pulling ing systems comply with the contract plans and speci-the wellpoints shall be filled with sand. Sump pump- fications with respect to materials, installation, main-ing of seepage and surface water thereafter shall con- tenance, and operation of the dewatering systems so as tinue as required to keep the excavation in an unwa- to control subsurface pressures, groundwater and seep-tered condition until all structural concrete work and age, and surface water, and maintain records as speci-backfill are complete, and the succeeding Contractor fied herein. The dewatering engineers duties shall has assumed responsibility for maintaining the exca- include the following:
vation in an unwatered condition. (1) Materials and equipment. The Contractors
- h. Method of measurement. Dewatering, as speci- dewatering engineer shall obtain all specified data fied in f above, to be paid for will be determined by the and supervise making all tests and/or measurements to number of calendar days (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />), counted on a day- determine that all materials incorporated in the work to-day basis, the excavation is maintained in an unwa- are in accordance with the plans and specifications.
tered condition and pressure relieved, from completion Materials and equipment to be checked shall include, and final acceptance of the concrete mat to the date on but not be limited to, well screens, riser pipes, filter which a written directive to cease pumping operations sand, pumps, column pipe, gear drives, couplings, die-is received from the Contracting Officer. sel engines, well discharge pipe and fittings, header pipe, valves, discharge system outlet structures, pie-
- i. Unit price. Any pressure relief wells and related zometers, and related appurtenances.
apurtenances required in addition to the specified (2) Installation. The Contractors dewatering pressure relief system shall be paid for at the unit engineer shall check to be sure that specified proce-price for additional pressure relief wells. dures and methods for installing wells, pumps, jet-G-6. Example of type B-2 specifications eductor wells, piezometers, and any other supplemen-(dewatering and pressure relief). tal dewatering or groundwater control system re-quired are installed in accordance with the specifica-
- a. Scope. This section covers: furnishing, install- tions and drawings.
ing, operating, and maintaining the dewatering sys- (3) Operation and maintenance. The Contractors tems shown on the drawings and specified herein; un- dewatering engineer shall supervise the operation watering the Phase I excavation; installing any addi- and maintenance of the dewatering systems, supple-tional dewatering wells, pumps, and appurtenances, if mental groundwater control facilities if any, surface necessary, to lower and maintain the hydrostatic wa- water control systems, and shall assist with obtaining ter level in the sand formation beneath the excavation all required piezometric, well performance, and flow to a level at least 5 feet beneath any Phase II excavated data. The Contractor shall inspect the test starting of surfaces, and have the capacity to lower the water lev- each nonoperating dewatering pump and engine in-el to elevations -29.0 and -35.0 feet beneath the stalled in a well or on the system on a weekly basis and chamber and gate bay sections, respectively, of the include in a daily report reference to the conduct of the lock for a Red River stage of elevation 60.0 feet; and test, the number of pumps and engines tested, and any controlling seepage from the soils above and below the unsatisfactory performance data and remedial action bottom of the excavation, not intercepted by the speci- taken. The Contractors dewatering engineer shall fied well and jet-eductor systems, by installing addi- notify the Contractor and the Contracting Officers tional jet-eductor wells, wellpoints, pumps, and appur- Representative (C.O.R.) immediately of any event or tenances if necessary, so as to assure a stable bottom at information not in accordance with the specifications.
grade for the Phase II excavation and prevent any sig- Thirty days prior to completion of the work under this nificant seepage or raveling of excavated slopes. The contract, the Contractor shall furnish to the Govern-dewatering systems shall include deep wells; jet-educ- ment a complete set of as-built drawings of the de-tor wells; wellpoints and/or sand drains if required; watering facilities installed, and all significant opera-pumps, engines, and piping; and related appurte- tional, maintenance, and performance data and rec-nances; and dikes, ditches, sumps, and pumps neces- ords.
sary for control of surface water. The dewatering sys- (4) Records. A copy of all inspection and test data tems shall remain in continuous operation, as speci- relating to materials, installation, operation and main-fied, until completion of this (Phase II) Contract and tenance, and performance of the dewatering systems, the systems are transferred to the Phase III Contractor and supplemental groundwater control facilities if or to the Government. any, as required, shall be promptly furnished to the
- b. Compliance with specifications and drawings. Contracting Officer.
G-8
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418
- c. General. The dewatering systems shall be in- ditional jet-eductor wells may be required to control stalled, operated, and maintained so as to reduce the seepage from other sections of the slopes around the artesian pressure in the sand formation below the ex- excavation. As shown by the boring logs and subse-cavation, and control seepage from any excavated quently referenced reports, the stratification of the slopes or into the bottom of the excavation as specified top stratum soils above the deep sands is erratic (more below, so that the work covered under this contract so in some areas than others). The deep wells and jet-can be accomplished in stable areas free of water and eductor wells, subsequently installed around the top or without heaving of soil strata overlying the sand aqui- upper berm for the excavation, may or may not com-fer within the cofferdammed area. pletely dewater or stabilize all slopes or areas in the (1) Dewatering requirements. Construction de- bottom of the excavation. Dewatering facilities for watering to be performed by the Contractor shall con- control of groundwater in the lower part or bottom of sist of: the excavation, if required, shall be designed by the (a) Dewatering lock and dam excavation by Contractor subject to approval of the Contracting Of-pumping from deep wells; jet-eductor wells; and any ficer. Facilities for unwatering the Phase II excava-other supplemental groundwater control facilities if tion, and controlling and sump pumping surface wa-required. ter, shall be designed by the Contractor.
(b) Unwatering the Phase I excavation. (b) The Contractor shall submit for approval by (c) Testing adequacy of deep-well system prior the C.O. within 15 calendar days after receipt of No-to and after unwatering the Phase I excavation. Eval- tice to Proceed complete information regarding meth-uation of the adequacy of the jet-eductor system after ods and equipment he or she proposes to utilize for in-unwatering the excavation. stalling the jet-eductor wells and pumping the dewa-(d) Controlling and removing of surface water tering wells required by these specifications. The Con-falling into the excavation. tractor shall at the same time submit detailed design The dewatering systems for Phase II excavation for data and drawings for the system he or she plans for the lock and dam shall be constructed in accordance controlling surface water and unwatering the excava-with the details shown on the drawings and the re- tion for the Phase I work. The material to be submitted quirements herein specified. The dewatering systems shall include, but not necessarily be limited to, the fol-shall be installed and operated by the Contractor to lowing: capacities and characteristics of all well and control seepage from any excavated slopes or the bot- jet-eductor pumps, engines, gear heads, flexible cou-tom of the excavation so as to assure a stable work plings, and standby equipment; description of equip-area at grade and prevent raveling or sloughing of ex- ment and procedures he or she proposes to use for in-cavated slopes, and to lower the hydrostatic water lev- stalling the dewatering wells, jet-eductor wells, and el in the deep underlying sand formation so that as the any supplemental dewatering facilities, if required, in excavation progresses the piezometric heads and the bottom or lower part of the excavation; calcula-groundwater table are maintained at least 5 feet below tions and drawings of dikes, ditches, sumps, pumps, the bottom of the excavation and 3 feet below the and discharge piping for unwatering the Phase I exca-slopes at all times, as measured by construction pie- vation and for controlling surface water; and a de-zometers. After the hydrostatic water level in the deep tailed description of his or her procedures and plans sand formation has been lowered to the required levels for supervising the installation, operation, and mainte-beneath the excavation, it shall be maintained at the nance of the dewatering systems to insure that the sys-required elevations so that all testing and construction tems are installed as specified herein and that they are operations can be performed in the dry without inter- operated and maintained so as to preserve the systems ruption. in first class working conditions subject to normal (2) Design of dewatering systems. The (dewater- wear, throughout the life of this contract.
ing) well system has been designed to lower the hydro- (c) Approval by the Contracting Officer of the static water level to elevation -26.0 feet in the deep plans and data submitted by the Contractor shall not sand formation beneath the excavation for the dam relieve the Contractor from the responsibility for con-and to elevation - 35.0 feet beneath the lock (or below) trolling surface water, seepage, and artesian head and with a river stage at elevation 60.0 feet, with as many groundwater levels in the excavated areas as, and to as two to five well pumps off depending on their loca- the extent, specified herein.
tion. (3) Responsibility. The Contractor shall be fully (a) The jet-eductor wells (indicated by borings responsible for furnishing, installing, operating, and made in and around the excavation) have been de- maintaining the dewatering and jet-eductor well sys-signed to drain semipervious soils in the top stratum tems, as specified, and any other seepage and surface to prevent or minimize any detrimental seepage from water control systems required for control of ground-the (main) excavated slopes around the excavation. Ad- water as herein specified. However, any jet-eductor or G-9
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 dewatering wells, pumps, piping, etc., required to con- the deep and jet-eductors dewatering wells, the Con-trol groundwater in the main excavated slopes around tractor shall submit a plan of his or her procedures and the excavation and in the deep sand stratum below the equipment for accomplishing the work within fifteen bottom of the excavation will be paid for as an extra. (15) days of his or her Notice to Proceed. After receiv-Any supplemental measures for control of seepage, ing approval of such procedures and equipment, he or whether perched or otherwise, in the bottom of the she shall install and test the above dewatering system, Phase II excavation or from excavated slopes in the including unwatering the Phase I excavation, within bottom of the excavation, will not be paid for as an ex- 120 calendar days. Any apparent deficiencies in the tra. deep or jet-eductor well systems for whatever cause (a) The Contractor shall be responsible for: in- shall be corrected within 15 calendar days after evalu-stalling and testing the dewatering well and jet-educ- ation of the pumping tests made on the systems and tor system as specified prior to and after unwatering notification by the Contracting Officer. There shall be the Phase I excavation; unwatering the Phase I excava- no unwatering of the Phase I excavation until the tion; dewatering and/or controlling any seepage from deep-well system has been installed and tested, and no specified excavated slopes or in the bottom of the exca- unwatering of the excavation more than 3 to 5 feet be-vation so as to prevent any raveling or other instabili- low any reach of the uppermost berm, where jet-educ-ty of the slopes while unwatering of the Phase I exca- tor wells are to be installed, until all of the jet-eductor vation and driving the test and foundation piling un- wells specified are installed.
der this contract; maintaining the hydrostatic water (5) Testing dewatering system. After the deep-level in the deep sand formation at least 5 feet below well dewatering system has been completely installed, the bottom of the excavation and any excavated its adequacy shall be checked by the Contractor mak-slopes, and controlling any detrimental seepage ing a pumping test on the entire system, as directed by emerging from pervious soils in the top stratum; low- the C.O.R., prior to unwatering the Phase I excavation ering the groundwater table in pervious or semiper- and at the completion of unwatering the Phase I exca-vious strata in the top stratum at least 3 feet below vation. The jet-eductor systems shall be continuously any excavated slopes except at the contact with an un- operated while unwatering the Phase I excavation and derlying impervious stratum; maintaining the bottom the adequacy of its performance evaluated after com-of the excavation free of all seepage or surface water pletion of unwatering and as the excavation for Phase until the end of this contract; and operating and main- II is carried to grade. The performance of the dewater-taining the dewatering systems. ing systems will be evaluated by the Government. If (b) The Contractor shall be responsible for in- the dewatering well system and jet-eductor wells are stalling and operating continuously the dewatering found to be inadequate to control the groundwater and well systems specified herein, and any other supple- artesian head below the excavation, they shall be sup-mental wells, pumps, and engines, necessary to lower plemented as provided for subsequently in these speci-and maintain the hydrostatic head in the deep under- fications.
lying sand formation 5 feet or more below any Phase II (6) Operation during contract. The Contractor excavation, and with the capacity of lowering the shall operate and maintain the specified dewatering groundwater table below elevation -29.0 feet in the well and jet-eductor systems and any supplementary chamber and elevation -35.0 feet in the gate bay wells or seepage control measures that may have been areas for the lock, for a projected Red River stage of installed, as needed to comply with these specifica-elevation 60.0 feet. The Contractor shall also be re- tions during the complete period of this contract.
sponsible for maintaining the groundwater table in (7) Transfer of dewatering system to Phase III silt, silty sand, and sand strata, penetrated by the Contractor. Upon completion of this contract, the Con-Phase I or Phase II excavation at least 3 feet below the tractor shall turn over the complete deep-well, jet-surface of the slope, and shall control any seepage at eductor, and surface water control systems and all the contact between seeping soil strata and impervious standby equipment to the Phase III Contractor or the strata occurring at any time which might otherwise Government who will at that time assume ownership cause raveling or instability of the slope at that level. and operation of the dewatering and surface water Any noncompliance with the above specified ground- control systems. The Phase III Contractor will be re-water control requirements shall be promptly rectified sponsible for removal of the systems in accordance in accordance with these specifications. with his Phase III contract.
(c) The Contractor shall be responsible for all (8) Unwatering excavation for Phase I contract. It damage to work in excavated areas caused by failure to will be the responsibility of the contractor to unwater maintain and operate the dewatering systems as speci- the excavation made during the Phase I contract for fied. this project. No unwatering of the excavation shall be (4) Installation sequence. Prior to installation of started until after the deep-well and jet-eductor dewa-G-10
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 tering systems have been completely installed and ini- ined at the New Orleans District Office or at the office tially tested. When, and if, the first full-scale pumping of _ _ _ _ _ . The Government guar-test conducted on the dewatering system shows the antees the accuracy of the basic river stage and pump-system adequate to lower and maintain the hydrostat- ing test data as obtained for the particular wells in-ic water level in the deep underlying foundation 3 to 5 stalled at the locations tested; however, as the logs of feet below the water level in the excavation as it is un- borings indicate, the characteristics of the subsurface watered, the Contracting Officer will advise in writing soils at the site vary considerably, and therefore the that the Contractor may proceed with unwatering the Contractor should not assume that the data obtained excavation. The water level in the Phase I excavation from the pumping tests made at the locations specified shall be lowered at a rate not to exceed 1 foot per day are representative of all conditions that exist at the or slower if there is any sign of raveling or instability site. Therefore, it shall be the responsibility of the of the excavated slopes. Contractor to make his or her own evaluation of the re-(9) Surface water control. The Contractor shall in- lation of the pumping test data to subsurface condi-stall, operate, and maintain dikes, ditches, sumps, tions at other locations at the site.
pumps, and discharge piping for controlling surface (c) The subsurface soils at the site consist of a water so as to prevent flooding of the work area for top stratum of clays, silts, and fine sands, with widely driving the test and foundation piles for the dam. varying degrees of arrangement and stratification, (10) Available soil and pumping test data. with a depth of about 80 to 120 feet. A stratum of (a) Some of the soil test data obtained by the rather pervious sand underlies the entire site with a Government are shown on the boring logs. Additional thickness of approximately 220 feet. The top of this logs of borings made for the project are plotted in _ _ deep thick sand stratum varies from about elevation
- - - - - - - - - - - - - - - - - - - - 20.0 to - 70.0 feet. Logs of three borings (M-1, M-2,
- - - - - - - - - - - - - dated and M-3) made 500 feet deep indicate that this sand
. The above report and additional labora- stratum is underlain by a clay stratum about 120 feet tory data and samples of soils from the borings shown thick at a depth of about 290 to 380 feet. This clay on the plans are available in the _ _ _ _ _ _ _ _ stratum may or may not be continuous. It is underlain
_ _ office of _ _ _ _ _ _ _ _ . by more sand to a depth of about 400 feet.
(b) Pumping tests have been performed on three (d) The Red River flows along and around a por-wells installed at the site. One of these test wells (Well tion of the site for the excavation, the deeper parts of A) was installed with 190 feet of l6-inch nominal di- the river in the vicinity of the excavation range from ameter well screen that more or less fully penetrated approximately elevation 10.0 to -20.0 feet. To what the deep sand aquifer beneath the excavation site; two extent the channel of the river provides an open source of the test wells (Wells B and C) were installed to a of seepage into the underlying deep sand formation is depth of approximately 80 feet for the purpose of test- not known; the logs of a few borings made in the bed ing the upper top strata of silty sands and sandy silts. and along the bank of the river are shown in the pre-The locations of the test wells and some of the piez- viously referenced report by . It will be ometers installed in connection with making the the responsibility of the Contractor to make his or her pumping tests are shown on the drawings. The eleva- own evaluation of the effect of the Red River on dewa-tion of the well screens for the test wells and piezome- tering and control of seepage into the excavation, not ters and logs of borings made along the piezometer otherwise covered by these specifications.
lines radiating out from the test wells were plotted. A (e) Chemical analyses of sample of groundwater hydrograph of the Red River and Piezometers PA9 and taken from Test Wells A, B, and C on 28 April 1978 PA9A installed 2970 and 3970 feet from Test Well A, gave the following results:
observed during the test on Well A, are shown on a Well A drawing of these specifications. Plots were made of 137-ft 260-ft drawdown observed while pumping Test Well A, cor- Total depth depth Well B Well C rected for an estimated (natural) change in the ground- pH 6.8 7.0 7.0 6.9 water table during these tests as a result of a rise on Chloride (Cl) 115 30 60 110 Suspended Solids (ppm) 52 34 62 37 the Red River. Results of the pumping tests made on Volatile Solids (ppm) 8 5.5 7 5 Test Wells B and C were also plotted. No correction Total Solids (ppm) 520 762 977 1620 was made for any natural change in the groundwater Total Dissolved Solids table during the pumping test on Wells B and C inas- (ppm) 468 728 915 1583 much as there was very little change in the river stage Total Volatile Solids (ppm) 50 65 88 227 during the pumping test on these wells. A report on Sulfate (ppm) 7 9 539 202 the pumping test made at the site by Hardness (CaCO3) (ppm) 390 423 694 1066 and design of the dewatering systems may be exam- Magnesium 26 28 54 94 G-11
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 Well A strata (with or without gravel and cobbles) may be en-137-ft 260-ft countered in drilling the holes for the specified wells.
Total depth depth Well B Well C Logs and wood debris have also been encountered in Manganese 2 2 1 1 making borings and drilling wells at some locations at Calcium (ppm) 105 95 165 244 the site.
Iron (total) (ppm) 8 19 13 9 Hydrogen Sulfide (ppm) <0.1 <0.1 <0.1 <0.1 (b) Depth of wells. The wells shall be installed to Total Alkalinity a depth so that the top of the specified length of screen (CaCO 3) (ppm) 405 479 567 480 (100 feet) is set approximately 5 feet below the top of Carbon Dioxide fine (or coarser) sand as determined at the time of (CO2) (ppm) 120 95 120 110 drilling by the C.O.R. The elevation at which the top of
- d. Deep-well dewatering system. the screen shall be set is shown on certain logs of bor-(1) Scope. The work provided for herein consists ings along the line of the dewatering wells. The top of of furnishing all labor, material, equipment, and tools to construct, develop, test pump, and disinfect the fil- to be set will probably vary from what is shown on the ter sand, well, and pump for the dewatering wells to be boring logs. The hole drilled for the wells will be installed around the perimeter of the excavation at the logged by the C.O.R. If buried logs or boulders are en-locations shown on the drawings and as specified here- countered which, in the opinion of the C.O.R., render in. The work also includes installation of the pumps, it impractical to advance the drill hole to the design diesel engines, gear drives, couplings, discharge pipes, depth, the C.O.R. may adjust the depth in order to uti-valves, fittings, flow measurement devices, and dis- lize the well in the system at the depth actually ob-charge pipe. tained, or he or she may request the Contractor to (2) Design. The deep-well system specified has abandon the well, plug the hole by backfilling, and been designed to lower the groundwater table in the construct another well at an adjacent location.
deep sand stratum beneath the excavation to elevation
- 26.0 feet beneath the dam, elevation - 29.0 feet be- (c) Drilling. The dewatering wells shall be neath the lock chamber, and elevation - 35.0 feet be- drilled by the reverse rotary method to a depth which neath the gate bays for a design Red River stage of ele- will permit setting the top of the screen in fine (or vation of 60.0 feet (estimated maximum river stage for coarser) sand as determined at the time of drilling by a frequency of 1 in 20 years). The purpose of the deep- the C.O.R. The water level in the sump pit and the well well system is to lower the hydrostatic head in this shall be maintained a minimum of 8 feet above the sand stratum so as to prevent seepage into the bottom groundwater table at all times until the well screen, of the excavation and to prevent any heave of imper- riser pipe, filter, and backfill have been placed. Drill-vious soil strata that overlie the deep sand formation ing of the well shall be carried out so as to prevent any in certain areas of the excavation. It is imperative that appreciable displacement of materials adjacent to the there be no heave of the bottom of the excavation dur- hole or cause any reduction in the yield of the well. (A ing either Phase II or Phase III construction of the lock temporary surface casing with a minimum length of and dam. If evaluation of the pumping test made at 20 feet shall be set prior to the start of drilling.) The the completion of unwatering the Phase I excavation diameter of the hole drilled for the well shall be 28 to indicates the need for additional dewatering wells, 30 inches. The hole shall be advanced using a reverse-pumps, engines, discharge piping, and appurtenances, rotary drill rig with a (minimum) 5-inch I.D. drill stem.
the Government will design the supplemental system While drilling and installing the well, the drill hole and furnish the design to the Contractor for installa- shall be kept full of (natural) drilling fluid up to the tion. The Contractor will be reimbursed for the cost of ground surface with turbidity of about 3000 parts per installing any supplemental wells, pumps, engines, million. No bentonite drilling mud shall be used while discharge piping, and appurtenances, when completely drilling or installing the well. Silt may be added to the installed and ready for operation. The Contractor shall drilling water to attain the desired degree of muddi-be responsible for designing any features of the well ness (approximately 3000 parts per million) if nec-system not specifically covered by these specifications esary. If natural turbid water, or with silt added, or drawings. proves insufficient to keep the hole stable, an ap-(3) Installation of wells. proved organic drilling compound such as Johnsons (a) Location of wells. The dewatering wells shall Revert, or equivalent, may be added to the drilling be installed at the designated locations. Soil conditions fluid. The Contractor shall dig a sump pit large enough in the areas where the wells are to be installed are de- to allow the sand to settle out but small enough so that picted in a general way by the boring logs made around some silt is kept in suspension. The drilled hole shall the excavation. Subsurface conditions and stratifica- be 3 feet deeper than the well screen and riser to be in-tion are erratic at this site, and clay, silt, and sand stalled in the hole. All drilling fluid shall be removed G-12
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 from the well filter and the natural pervious informa- with the manufacturers recommendations prior to tion after the well is installed. surging.) Development of the well shall be started (d) Installation of well screen and riser. within 4 to 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after the well has been installed.
Step 1. Assembly. The joints between the Surging of the well shall be accomplished with a surge screen sections and between the screen and riser pipe block raised and lowered through the well screen at a shall be welded with stainless steel rod. Particular care speed of 2 to 3 feet per second. The gaskets on the should be exercised to avoid damaging the screen and surge block shall be slightly flexible and have a diame-riser. It shall be centered in the well hole or casing and ter about 1 inch smaller than the inside diameter of held securely in place during placement of the filter by the well screen. The amount of material deposited in means of spiders and approved centering guide, tremie the bottom of the well shall be determined after each holder, or other approved method. Prior to installation cycle (about 10 to 20 trips per cycle). Surging shall con-of any screen and riser the Contractor shall submit to tinue until the accumulation of material pulled the Contracting Officer for approval full details of the through the well screen in any one cycle becomes less method, equipment, and devices he proposes to use for than 0.2 foot. The well screen shall be bailed clean centering and holding the screen and riser pipe in the with a piston-type bailer when the accumulation of well hole. material in the bottom of the screen becomes more Step 2. Installation. The assembled screen and than 2 to 3 feet at any time during surging; the well riser pipe shall be placed in the well hole in such a shall also be cleaned after surging is completed. After manner as to avoid jarring impacts and to insure that completion of surging, the well shall be pumped with the assembly is not damaged or misaligned. the pump section about 1 foot off the bottom of the Step 3. Alignment. Each completed well shall well until the discharge is clear and is reasonably free be sufficiently straight and plumb that a cylinder 10 of sand (less than 10 to 20 parts per million sand).
feet in length and 2 inches smaller in diameter than Such pumping shall begin within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after surging the inside diameter of the well may be lowered for the and shall continue for not less than 30 minutes. The full depth of the well and withdrawn without binding well shall be pumped so as to achieve a drawdown of against the sides of the screen or riser pipe. A varia- not less than 20 feet, or a flow of approximately 1000 tion of 6 to 12 inches will be permitted in the align- gallons per minute, whichever is first. If, at the com-ment of the screen and riser pipe from a plumb line at pletion of pumping, the well is producing sand at a the top of the well; however, this will not relieve the rate in excess of 10 to 20 parts per million, it shall be Contractor of the responsibility of maintaining ade- resurged and pumped again. Alternate surging and quate clearance for bailing, surging, and pumping re- pumping shall be continued until material entering the quired for pumping the wells. well during either surging or pumping is less than the (e) Placement of sand filter (A). After the screen amount specified above, but not for a period longer and riser pipe have been placed, the filter sand shall be than 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. Wells which continue to produce an ex-tremied into the annular space between the well screen cessive amount of sand or filter material during devel-or riser pipe and the drilled hole using a 4- or 5-inch-di- opment shall be abandoned as requested by the C.O.R.
ameter tremie pipe with flush screw joints and at least except that, if he or she so elects, he or she may re-two slots 1/16 inch wide and about 6 inches long per lin- quest the Contractor to continue to develop the well by ear foot of tremie. The tremie pipe shall be lowered to an approved method. If, after such further develop-the bottom of the hole and then filled with filter sand. ment, a well meets the above stated requirements, it (If the filter sand has a tendency to segregate, the fil- shall be completed, and after successful completion of ter sand shall be kept moist following delivery to the the required pumping test, the well will be accepted.
work site in order to minimize segregation.) After the If, after completion of all surging and pumping, there tremie has been filled with filter sand, it shall be slow- is more than 0.5 foot of material in the bottom of the ly raised, keeping the tremie full of filter sand at all well, such material shall be carefully removed with times until the filter sand has filled the hole up to either a piston-type bailer or by pumping. The water within 15+/- feet of the ground surface. The bottom of resulting from pumping the well shall be discharged the tremie pipe shall be kept slightly below the surface outside the work area at locations approved by the of the filter sand in the hole as the tremie is raised. C.O.R. Pertinent data regarding installation of the (f) Development of well. After installation of wells will be recorded by the C.O.R. After completion the well, it shall be developed by surging with a surge of satisfactory development of a well, the grout seal block and pumping, as described below, for not less shall be placed.
than 30 minutes. (If Revert or equivalent approved or- (g) Disinfection of drill hole and filter sand.
ganic drilling additive has been used in drilling the During the drilling operation, a minimum of 1 pound hole, a breakdown agent such as Johnsons Fast-Break of calcium hypochlorite shall be added to the drilling or equivalent shall be added to the well in accordance fluid every 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. As the filter sand is placed in the G-13
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 well, calcium hypochlorite shall be added to evenly dis- (b) The pump shall be capable of pumping at the tribute a minimum of 2 pounds per ton of filter. Upon rate of 1500 gallons per minute, over a period of time completion of development of the well and prior to in- sufficient to satisfactorily perform the pumping test stalling the well cover, a minimum of 5 pounds of specified. An approved means for accurately determin-granular 70 percent calcium hypochlorite shall be ing the water level in the well and a calibrated flow dropped in the well and allowed to settle to the bot- meter or orifice of standard design for the purpose of tom. measuring the discharge from the well during the (h) Covers. The top of a well shall be sealed im- pumping test shall be provided. The Contractor shall mediately after completion of installation with a wa- furnish and install the necessary discharge line so that tertight seal which shall be kept in place at all times, the flow from the well can be pumped into an adjacent except during cleaning and pumping operations, until area approved by the C.O.R. The pumping and sand in-the pump and gear drive are installed. filtration test shall be conducted in the presence of the (i) Abandoned wells. Holes for wells abandoned C.O.R., who will record the following test data: well prior to placement of well screen and riser pipe shall number, location, top of riser (mean sea level), date be filled with sand and cement grout. Wells abandoned and time test started and stopped, depth to water in after placement of well screen and riser pipe may be well before and at end of pumping, elevation of water pulled and the remaining hole filled with sand to with- in well immediately before and at the end of pumping, in 25 feet of the surface. The remaining 25 feet should rate of sanding at end of pumping period, and depth of then be backfilled with an approved cement grout. sand in well after cleaning.
Bentonite may be added to the grout to improve its (c) The Contractor shall test each well by pump-pumpability. If the Contractor elects to leave an aban- ing continuously for a minimum of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. Pumping doned well screen and riser in place, it shall be plugged shall be at a constant rate sufficient to produce either as described above. Wells which are abandoned as a re- a drawdown of 20 feet, or a constant rate of flow of sult of alignment or plumbness being outside of these 1500 gallons per minute, whichever occurs first. The specifications, or wells which produce sand in excess of computed rate of sanding shall take into consideration 5 parts per million after development and pump test- the pumping rate, the rate of sand emerging from the ing, shall be replaced by the Contractor at no cost to pump, and the amount of emptying or buildup of sand the Government. in the bottom of the well during the (sand) testing peri-(j) Well records. The following information re- od as determined accurately with a flat-bottom sand-garding the installation of each well will be recorded ing device. No test pumping of a well will be permitted by the C.O.R. The Contractor shall cooperate and as- concurrently with drilling, surging, or pumping of any sist the C.O.R. in obtaining the following informa- other well within 300 feet thereof.
tion: well number, location, top of riser (mean sea lev- (d) In the event that sand or other materials in-el), date and time test started and stopped, depth to filtrate into the well during the pumping test, the fol-water in well before and at end of pumping, elevation lowing procedure will be followed: If the rate of sand of water in well immediately before and at end of infiltration during the last 15 minutes of the pumping pumping, flow in gallons per minute, depth of sand in test is more than 5 parts per million, the well shall be well before and after completion of pumping, rate of resurged by manipulation of the test pump for 15 min-sanding at end of pumping period, depth of sand in utes after which the test pumping shall be resumed well after cleaning, screen length, depth of hole, inside and continued at the rate specified above until the depth of well, depth to sand in well after cleaning, top sand infiltration rate is reduced to less than 5 parts of well screen (mean sea level), top of filter (mean sea per million. If at the end of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> of pumping the level), bottom of well (mean sea level), top of well, rate of infiltration of sand is more than 5 parts per method of surging, material surged into well (last cy- million, the well shall be abandoned unless the C.O.R.
cle) in feet, total material surged into well in feet, rate requests the Contractor to continue to test pump and of pumping and drawdown, total pumping time, and perform such other approved remedial work as he con-rage of sand infiltration at end of pumping in parts per siders desirable. If, after such additional test pumping million. and other remedial measures, the sand infiltration (4) Pumping test on each well. rate of the well is reduced to less than 5 parts per mil-(a) Upon completion of installation, surging, lion, the well will be accepted. Upon completion of the and developing pumping, each well shall be subjected pumping test, any sand or filter material in the bottom to a pumping test. Prior to commencement of the of the well shall be removed by pumping or with a pis-pumping test, and again after completion of the pump- ton-type bailer.
ing test, the depth of the well shall be measured when (5) Installation of pump and chlorination. Each the C.O.R. is present by means of an approved flat-bot- dewatering well shall be chemically treated with cal-tom sounding device. cium hypochlorite (chlorine) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after the G-14
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 test pump is removed. A solution of calcium hypochlo- tractor shall have at the jobsite five new complete die-rate (HTH) shall be mixed with water in a tank (mini- sel power units. During the pumping period, the mum capacity of 3000 gallons to obtain a 1000-parts- Contractor shall have a minimum of five (new or re-per-million chlorine solution). (Fifteen pounds of (dry) manufactured) diesel power units, complete with all 70 percent calcium hypochlorite will make 1000 gal- components, available as standby. The Contractor lons of 1000-parts-per-million chlorine solution.) A shall also keep in stock on the jobsite other miscellane-minimum of 30 gallons per foot of screen shall be ous spare parts essential to routine maintenance of the pumped into the well through a hose extended to the engines, pumps, gear heads, flexible couplings, valves, bottom of the well. As the chlorine solution is pumped etc., as considered appropriate and approved by the into the well, the hose shall be withdrawn at a rate C.O.R.
which will insure that the chlorine solution is added (c) Pumps. Deep-well turbine pumps, similar or uniformly from the bottom of the well to a point 10 equivalent to such pumps manufactured by Layne-feet above the top of the well screen. The chlorine solu- Bowler, Fairbanks-Morse, Johnston, Jacuzzi, or other tion in the well shall then be surged with a loose fitting qualified pump manufacturer, shall be designed for surge block for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. The permanent dewatering pumping clear water at a rated capacity of 1500 gal-pump shall then be immediately installed, and the well lons per minute at a total dynamic head of 200 feet pumped until the chlorine is essentially removed. (If it and pump speed of 1800 revolutions per minute with a is not possible to promptly install, the permanent bowl efficiency of about 80 percent. The pump bowl as-pump, the chlorine should be allowed to set 3 or 4 sembly shall be of close-grained cast iron porcelain hours, and the well pumped by some means to remove enamel-coated inside and fitted with replaceable the chlorine.) If the permanent pump is subsequently bronze wear rings and sleeve-type shaft bushings. Im-installed, the well and pump shall be rechlorinated as pellers shall be cast iron or bronze and designed for described above except the surging shall be omitted. nonoverloading. The bowl shaft shall be high-chrome (6) Equipment and materials. stainless steel of sufficient diameter to transmit the (a) Quality. All installed equipment and mate- pump horsepower with a liberal safety factor and rig-rials shall be new except the discharge header system idly support the impellers between the bowl or case which may be either new or like new used pipe. bearings. The pump column assembly shall consist of (b) Power units. Each of the 64 deep wells shall thirteen lo-foot sections of lo-inch steel threaded pipe be equipped with a direct drive diesel power unit. The with line pipe couplings. Bronze spiders with rubber engines shall be certified to produce a minimum of 115 bearings shall align the shaft bearings in each section.
continuous net horsepower at 1800 revolutions per Line shafts shall be of Grade 1045 (ASTM A 108) steel minute to the gear drive and shall be a Caterpillar ground and polished with Type 304 (ASTM A 743)
Model 3304 T, Detroit Diesel Model 4-71N, or equiva- stainless steel sleeves to act as a journal for each rub-lent as approved by the Contracting Officer. The unit ber line shaft bearing. A lo-foot section of lo-inch shall be skid mounted with clutch power takeoff, have threaded suction pipe shall be screwed into the bottom hood and side panels, fan shroud, muffler, high tem- of the pump bowl, The discharge head shall be provid-perature and low oil pressure shutdown, battery, and ed for mounting the gear drive and supporting the fuel supply. Any additional item to make the unit pump columns, bowls, and suction pipe. The design function on a continuous 24-hour-per-day operation shall permit the drive shaft to be coupled about the shall also be included. Engines shall be operated with- stuffing box to facilitate easy removal and replace-in the revolution-per-minute limits of the manufactur- ment of the driver. The stuffing box shall be of the ers recommendations. The unit shall be leveled and deep bore type with a minimum of six rings of packing mounted on a 6-inch-thick concrete base. Prior to oper- and a steel case. The packing gland shall be the bronze ation, each unit shall be started and serviced by a split-type and secured with stainless steel studs and manufacturers factory trained representative, or silicone bronze nuts.
equally qualified mechanic. The power units shall be (d) Gear drive and flexible coupling. A right operated and maintained in accordance with the angle gear drive with a gear ratio of 1:l shall be in-manufacturers recommendations. Each power unit stalled on each pump. Horsepower rating shall be shall have an independent fuel tank with a capacity of based on American Gear Manufacturers Association at least 500 gallons. Fuel lines shall be provided with standards for spiral bevel gears. Ball and roller bear-an approved screen or filter and shall be attached to ings shall have a capacity to carry the horsepower and the tank so that rain or contaminants may not enter thrust loads for a minimum of 20,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />. The hous-the tank. The tank shall be properly vented and ing shall be a rigid semisteel casting properly propor-equipped with a drain plus and filler port. All fuel tioned to insure correct alignment of the gears under tanks shall be new and cleaned prior to being placed in full load. Case-hardened spiral bevel gears shall be service. At the commencement of pumping, the Con- held in position by antifriction bearings selected to G-15
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 convey the loads over a 4-year period of operation. A wrapped and welded on 0.177-inch round rod. The well large stream of oil shall be pumped to the gears and screen shall be furnished in lengths of 10 or 20 feet.
bearings by a pump located in the base of the housing. One section of screen for each well will be provided The vertical shaft shall be hollow to allow for easy ad- with a stainless steel bottom plate.
justment of the pump shaft. Provision shall be made (j) Filter sand. The filter around the well screen for circulating water through a copper coil installed in- and riser pipe shall be an approved washed (clean) sand side the case. A flexible drive shaft, Watson-Spicer or crushed stone composed of hard, durable, uniformly WL-48, or equal, shall be provided with each gear graded particles free from any inherent coating. The drive. The shaft shall be a minimum of 36 inches long filter sand shall contain no detrimental quantities of and provided with drive flanges to fit the engine and vegetable matter, nor soft friable, thin, or elongated gear drive. A protective cover made of galvanized particles, and shall meet the following gradation re-sheet metal or expanded metal shall be permanently quirements:
attached between the engine and gear drive to shield Filter Sand A the drive shaft. U.S. Standard Percent by weight (e) Standby equipment. At the commencement Sieve No. passing of pumping, the Contractor shall provide and have in 1/4 100 stock at the jobsite three new complete standby tur- 4 95-100 6 85-100 bine pumps. During the pumping period, the Contrac- 10 55-85 tor shall continue to have a minimum of three (new of 14 28-65 rebuilt) pumps available as standby units, which shall 16 20-55 be complete with column, shafting, pump head, gear 20 10-32 drive, and flexible coupling. 30 0-18 40 0-10 (f) A minimum of 20 feet of each size of header pipe and two of each size of Dresser couplings (or If blending of two or more sands is required to obtain equivalent) shall be on site for emergency repair if nec- the specified gradation, the blending shall be accom-essary. Twelve S-inch flanged nipples shall also be kept plished so as to achieve a uniform mix approved by the on site for adding S-inch rubber or plastic cloth dis- C.O.R.
charge hose for emergency pumping of the deep wells (k) Discharge system. The discharge piping is in event of discharge pipe failure. Sixty-five hundred for the purpose of conveying the water from the dewa-feet of S-inch rubber or plastic cloth hose shall be kept tering wells to the flotation channel on the south side on site for pumping of individual wells. of the cofferdam area. Under no conditions shall the (g) Operation and repair or replacement. The Contractor discharge water from the dewatering sys-pumps shall be operated so that the water level in the tems outside of the cofferdam dike other than at the wells is not lowered below the pump bowl. The pumps specified location. The header pipe installed at the and engines shall remain in operable condition at all specified locations shall be standard structural grade times with no more than two wells or pumps being in- pipe with the following minimum wall thicknesses:
operative at any one time. No two adjacent wells or Pipe diameter, inches Minimum wall thickness, inches pumps shall be inoperative at the same time. The Con- 12 0.22 18 0.25 tractor shall take immediate steps to repair or replace 24 0.25 any well, pump, gear drive, or engine which is inopera- 30 0.25 tive. Should the efficiency of a dewatering well show 36 0.28 any significant reduction from its initial efficiency, 42 0.28 the Contractor may, at the direction of the C.O.R., be The diameter of the pipe will vary from 12 to 42 required to redevelop and/or chemically treat the well inches. Connections may be made either by welding or as directed by the Contracting Officer, the cost of by Dresser couplings with tie rods. The pipe shall be which will be paid for under paragraph 3 (Changes) of laid straight, on approved blocking, in a workmanlike the General Provisions of the Contract. manner. Where crossing a road or ramp, the pipe shall (h) Riser pipe. The riser pipe for the wells shall be laid in an open separate culvert. The discharge pipe be 16-inch diameter, 0.250-inch or thicker wall, steel through the cofferdam dike shall have welded joints pipe. and be provided with seepage fins. A 42-inch Calco, (i) Well screen. The well screen shall be John- or equivalent, flap gate shall be installed on the end of son, Houston, or equal, wire-wrap type 304 stainless each discharge pipe. The discharge line from the well steel screen with a minimum inner diameter of 15 to the header shall be 8 inches in diameter and include inches (16-inch pipe size) with a nominal length of 100 a gate valve that can be locked or will remain in a fixed feet. The width of the slots will be 0.040 inch. The position while partially closed, a positive check valve (keystone or trapezoidally shaped) screen wire shall be and a pitometer cock for insertion of a pitot tube to G-16
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 measure well flow. Certain wells shall be provided quacy of the deep-well system will be evaluated on the with a tee and blind flange for connection of an 8-inch basis of the pumping test made upon completion of discharge hose in event of damage or failure of the unwatering of the excavation, for a Red River stage of main discharge header pipe. The Contractor shall con- elevation 60 feet. If at the end of the pumping test, an struct splash facilities for discharge water at the analysis of the data by the Contracting Officer or his dredge channel. The Contractor shall maintain the dis- C.O.R. indicates the system to be adequate, it will be charge splash facilities so as to prevent erosion or dam- approved; if the dewatering well system appears to be age to the channel slopes and to modify such if found inadequate, for a design Red River stage of elevation necessary. 60 feet, the Contracting Officer will direct the Con-(7) Pumping test on the dewatering systems. tractor to install additional dewatering wells, pumps, (a) After the deep-well dewatering system is engines, and necessary pertinent piping and fittings completely installed, a pumping test shall be made on for which he will be compensated as an extra.
the entire system by pumping all the wells at the same (e) If it appears, while unwatering the Phase I time at a constant pump speed or flow rate for each excavation and the second pumping tests on the deep-well, the pumping rate to be determined by the C.O.R. well system, that the groundwater table in the top prior to the test. If the selected pumping rate lowers stratum has not been adequately lowered by the speci-the water level in any well below the pump bowl, the fied jet-eductors wells and pumping the deep-well sys-engine speed shall be reduced or the discharge valve tem, the Contractor shall install whatever additional partially closed so that the water level in that well is jet-eductor wells, pumps, and piping considered neces-not lowered below the pump bowl. sary by the C.O.R. for which he will be compensated as (b) This test, the first, shall be made prior to an extra.
starting to unwater the Phase I excavation. The wells e. Jet-eductor well system.
shall be pumped continuously for at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and (1) Scope. The work provided for herein consists for not more than 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> as required by the C.O.R. of furnishing all labor, material, equipment, and tools The Contractor shall have previously installed the M to install, develop, and test pump the jet-eductor wells piezometers around the perimeter of the excavation, to be installed around the perimeter of the excavation the R, S, and T piezometers on lines out from the exca- at the locations shown on the drawings and as speci-vation, and provision has been made to measure the fied herein.
flow as shown on the drawings and specified herein. (2) Design. The jet-eductor wells to be installed on The C.O.R. will keep a systematic record of discharge the upper berm around the excavation at elevation 28 throughout the test period and will record the water to 34 feet are to intercept the seepage from silt, sandy level in the piezometers and wells immediately prior to silt, silty sand, and sand strata which are penetrated in commencing the test and at certain intervals thereaf- some areas by the outer excavation slopes. The pur-ter. The pumping test shall be conducted under the pose of the jet-eductor wells is to lower the groundwa-general direction of the C.O.R. with the Contractor be- ter table below the slopes of the main excavation and ing responsible for actual operation of the system. to prevent any detrimental raveling or instability of (c) If an analysis of the pumping data by the the slopes caused by seepage. The jet-eductor wells Government indicates probable adequacy of the sys- shown on the contract drawings and as specified here-tem, the Contractor may start unwatering the Phase I in have been designed to lower the groundwater table excavation while continuing to operate the dewatering in the upper silts and sands to within about 2 or 3 feet well system so as to maintain the groundwater table in of the contact with any underlying impervious the deep sand formation, as indicated by the M piez- stratum where shown on the drawing. However, other ometers installed around the top of the excavation, 3 reaches of the outer excavated slopes than shown on to 5 feet or more below the water level in the excava- the drawings may require dewatering or drainage. If tion. observations indicate the need for dewatering other (d) After the Phase I excavation is unwatered, reaches of the outer slopes, the Government will all wells shall be pumped at a constant rate to be pre- design the supplemental jet-eductor wells and system scribed by the C.O.R. for at least 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> and not and furnish the design to the Contractor for installa-more than 120 hours0.00139 days <br />0.0333 hours <br />1.984127e-4 weeks <br />4.566e-5 months <br />, as determined by the C.O.R., as tion. The Contractor will be reimbursed for the cost of a further check on the adequacy of the dewatering well any supplemental wells, jet-eductor pumps, and piping system with the excavation unwatered. As during the when completely installed and ready for operation, as first test, the rate of flow from each well and the en- an extra. The Contractor shall be fully responsible for tire system shall be measured throughout the test pe- controlling the groundwater table and seepage from riod, and the water level in the M, R, S, and T piezom- and below the main excavated slopes as specified eters and in the dewatering wells will be measured and herein, and for proper installation, operation, mainte-recorded at certain intervals during the test. The ade- nance of the specified jet-eductor wells, and any sup-G-17
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 plemental dewatering measures installed for control- bridging of the sand in the sanding casing. As the fil-ling the groundwater within the excavation. ter material is placed in the well screen, 70 percent (3) Installation of jet-eductor wells. granular calcium hypochlorite shall be added to evenly (a) Location and depth of wells. The jet-eductor distribute a minimum of 2 pounds per ton of filter. The wells shall be installed at the designated locations. Soil method of placement shall be approved by the C.O.R.
conditions where the jet-eductor wells are to be in- (d) Development of jet-eductor wells. Within 12 stalled are depicted in a general way by the logs of bor- hours after installation of each well, it shall be devel-ings made around the excavation. The wells should oped by means of air-lifting. A 2-inch inner diameter extend about 2 feet below the bottom of the pervious air line shall be lowered in the well to within 1 foot of strata being drained. The required depth of the wells the bottom of the well and sufficient air be pumped may vary considerably from those indicated on the through the air line to cause the well to flow. For low-drawings. yielding wells, it may be necessary to add clear water (b) Drilling and jetting. The jet-eductor wells to help develop the well and remove any sand that may shall be installed in the following manner: have entered the screen. Air-lifting shall continue un-Step 1. Predrill a 10- or 11-inch hole 2 feet til all sand or filter material is removed from inside below the silt or silty sand stratum to be drained. Hy- the screen and water from the well flows clear. Each draulic rotary, or auger, methods of drilling may be well shall be developed for a minimum of 20 minutes.
used. No drilling muds or additives, other than clear (e) Chlorination of well. Upon completion of in-water, shall be used in drilling the hole for the well. stallation of the well and prior to installing a cap on The hole shall be kept full of water during the predrill- the top of the riser, a minimum of 3 pounds of 70 per-ing, and withdrawal of the auger, so as to minimize cent granular calcium hypochlorite shall be dropped caving. into the well.
Step 2. After predrilling the hole to grade, it (f) Well top. The 4-inch riser shall extend 6 shall be washed out by driving and jetting (with clear inches above the ground surface and shall be sealed water) a 12-inch sanding casing with a hole puncher around the riser pipe for the jet-eductor pump. The to the bottom of the predrilled hole. well number shall be painted on the top of the riser Step 3. After the sanding casing is driven and pipe.
jetted to the required depth, it shall be washed clean (g) Riser pipe. The 4-inch riser pipe for the wells by jetting with clear water. The jet pump, pipe, and shall be 15 feet in length. The filter sand shall extend hose shall be of sufficient capacity to produce an up- to within 8 to 10 feet of the berm surface; the space ward velocity inside the casing to efficiently remove around the riser pipe from the filter to the berm sur-all material in the casing, so that the well screen and face shall be grouted with an approved bentonite-ce-riser can be set to grade. The sanding casing shall be ment grout.
kept filled with water until the well screen and filter (h) Well records. A report showing depth, eleva-sand have been placed so as to prevent any blow in of tions, date of installation, approximate rate of flow the bottom of the hole. during development, and any other data concerning in-(c) Installation of well screen and filter sand. stallation of each well will be completed by the C.O.R.
After the sanding casing has been cleaned by jetting The water level in the well shall be recorded at the and the clear depth in the casing checked by sounding time of installation. The Contractor shall assist in ob-with an approved device, the well screen shall be low- taining the installation data. If the jet-eductors or ered to the bottom of the casing. Particular care shall pumps appear to be losing their efficiency with the be exercised in handling and placing the screen so as passage of time, the Contractor may be required to re-not to damage it. Complete assembly of the screen and develop and/or chemically treat the wells as directed riser pipe on the ground surface will not be permitted. by the Contracting Officer, the cost of which will be Two or three connections shall be made to the assem- paid for under paragraph 3 (Changes) of the General bly as it is placed in the casing. Approved centralizers Provisions of the Contract.
shall be furnished and attached to the screen at inter- (4) Materials .
vals not greater than 20 feet. The design and attach- (a) Riser pipe. The riser pipe and the 2-foot ment of the centralizers to the well screen shall be sub- blank pipe on the bottom of the screen shall be 4-inch mitted to the C.O.R. for approval. The top of the riser diameter, flush-joint Schedule 80, type 2110 PVC pipe shall be securely covered or capped to prevent the pipe.
filter sand from falling into the well. The method of (b) Screen. The screen shall be 4-inch, Schedule placement shall assure a fairly rapid, continuous, uni- 80, type 2110 PVC screen. The screen shall be slotted form rate of placement of filter sand, which will with .025-inch slots in sufficient numbers to give a evenly distribute the filter sand around the screen. minimum area of opening of 5 percent. The screen sec-The rate of placing the filter sand shall not cause tion of the well shall extend from the top of any semi-G-18
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 pervious strata as shown by the boring logs, or as en- and drawings to be submitted shall include, but not countered, to the depth specified. necessarily be limited to:
(c) Filter sand. Filter sand around the well (a) Location and size of sumps, pumps, and screen shall be washed (clean) uniform sand or crushed dikes.
stone composed of hard, tough, and durable particles (b) Height and elevation of dike around free from any adherent coating. The filter sand shall excavation.
contain no detrimental quantities of vegetable matter, (c) Characteristics of sump pumps and nor soft, friable, thin, or elongated particles, and shall horsepower of engines.
meet the following gradation requirements: (d) Location and size of discharge piping. (Sur-Filter Sand B face water shall not be pumped into the discharge header for the dewatering (well) system).
U.S. Standard Percent by weight Sieve No. passing g. Dewatering perched groundwater in lower 8 95-100 part or bottom of excavation. The Contractor shall be 10 92-100 fully responsible for design and installation of any sup-14 75-100 plemental dewatering facilities that may be required 16 65-95 to control any seepage or groundwater in the bottom 20 30-77 30 10-30 or lower part of the excavation in order to assure a sta-40 1-13 ble subbase and permit work to be conducted in the 50 0-5 dry. These supplemental measures may include well-(5) Jet-eductor pumps and header pipe. The jet- points, sand drains, French drains, and appropriate eductor pumps shall have the specified pumping ca- pumps, piping, and appurtenances as necessary and pacities. The pressure pumps for operating the jet- approved by the C.O.R. subject to satisfactory perfor-eductor pumps shall have a diesel engine with a horse- mance of the facility installed. Pay for any such sup-power of at least 110 and a capacity of 1800 gallons plemental dewatering, if required, for the lower or bot-per minute at a total dynamic head of at least 150 feet tom part of the excavation should be included in the on a continuous basis. The standby pumps shall have price for excavation. There will be no charges or claims the same horsepower and capacity. The pressure for extra compensation or time extension for any sup-header pipe shall be Schedule 40; the return header plemental dewatering performed in the bottom or pipe shall have a minimum wall thickness of 0.20 inch. lower part of the excavation.
The sump pumps for the jet-eductor systems shall be h. Monitoring dewatering systems.
an electric, automatic priming type, with a capacity of (1) General. Continuous control of seepage into pumping 600 gallons per minute at TDH = 50 feet. and artesian pressure beneath the excavation is essen-
- f. Surface water control tial for driving the test and foundation piles for the (1) The Contractor shall be fully responsible for dam, and subsequent construction of the lock and designing all features of the system for unwatering the dam. It is therefore imperative that the dewatering excavation and controlling surface water that may fall systems have adequate capacity to control the ground-into the excavation. The sump pumping system shall water beneath the slopes and the excavation as speci-be designed with sufficient storage and pumping ca- fied at all times. In order to check the adequacy and pacity to prevent flooding the bottom of the excava- performance of the dewatering systems, the Govern-tion for the dam for at least a 1 in lo-year rainfall in- ment will make the following measurements and eval-tensity, assuming 100 percent runoff, for the follow- uate the data:
ing periods: (a) Measure the groundwater table beneath the Rainfall bottom of the excavation by means of M, R, S, and T Period Intensity, inch/hour Amount, inches piezometers installed in the deep sand aquifer that 30 minutes 4.5 2.25 underlies the site at specified locations.
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> 3.0 3.00 (b) Measure the groundwater table at selected 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2.0 4.00 locations where the excavation penetrates silts and In any event, the Contractor shall be responsible for silty sands in the top stratum overlying the deep sand controlling whatever surface runoff occurs, regardless formation by means of N piezometers installed at the of rainfall intensity, so as to protect the area for pile locations.
driving and testing from flooding. (c) Measure the flow from individual wells and (2) The Contractor shall submit for approval with- from the complete dewatering system.
in 15 calendar days, after he or she has received a No- (d) Measure the water level in the dewatering tice to Proceed, drawings, design data, and charac- wells.
teristics of the equipment he proposes to utilize in (e) Measure sand in the flow from dewatering unwatering and controlling surface water. The data wells.
G-19
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 (f) Measure the head loss through the filter and to keep the drilled hole open. The tip of the piezom-well screen for selected wells. eters shall be installed at approximate depths or eleva-(g) Read river stages. tions as approved by the C.O.R.; piezometers shall also The piezometers for monitoring the groundwater table be installed as instructed. The hole for a piezometer beneath the slopes and bottom of the excavation shall shall be kept filled with water or an approved organic be installed by the Contractor. The pitometers for drilling fluid at all times. Bentonitic drilling mud shall measuring the flow from individual wells and from the not be used. Any auger used in advancing the hole complete system will be furnished by the Government. shall be withdrawn slowly from the hole so as to mini-Copies of the data obtained by the Government will be mize any suction effect caused by withdrawing the promptly furnished to the Contractor. The Contractor auger. (Hollow-stem augers shall be filled with drilling will furnish and install the pitometer inserts. Opera- fluid before pulling the plug in the bottom of the tion and maintenance of the dewatering systems, any auger.) Drilling and installation procedures shall be as supplemental groundwater control facilities if re- specified below and shall be in accordance with ac-quired, and surface water control facilities shall be su- cepted practice and to the satisfaction of the C.O.R.
pervised by someone trained and with at least 5 years Method 1. Hollow-stem auger. After advancing of actual experience in managing large dewatering sys- the hole for the piezometer to grade (1 to 2 feet below tems and operating pumps and engines. the piezometer tip), or after taking the last sample in a (2) Piezometers. hole to receive a piezometer, the hollow-stem auger (a) Locations. The M, R, S, and T piezometers shall be flushed clean with water and the plug rein-shall be installed to measure the groundwater table in serted at the bottom of the auger. The auger shall then the deep sand formation beneath the excavation, be- be slowly raised to the elevation that the piezometer tween the dewatering wells, and on three lines out tip is to be installed. At this elevation the hollow stem from the excavation at the approximate locations shall be filled with clean water and the plug removed.
shown on the drawings. The N piezometers shall be in- Water shall be added to keep the stem full of water stalled to measure the groundwater table in semiper- during withdrawal of the plug. The hole shall then be vious strata in the bottom of the excavation and mid- sounded to determine whether or not the hollow stem way between jet-eductor wells at the approximate loca- is open to the bottom of the auger. If material has en-tions. The Contractor shall stake the piezometers at tered the hollow stem of the auger, the hollow stem designated locations. The tips of M, R, S, and T pie- shall be cleaned by flushing with clear water, or clean zometers for measuring the groundwater table in the Revert drilling fluid, if necessary, to stabilize the bot-deep sand formation shall be set in clean sand at eleva- tom of the hole, through a bit designed to deflect the tion -80.0 feet or below as necessary; the tips of the N flow of water upward, until the discharge is free of soil piezometers for measuring the groundwater table in particles. The piezometer screen and riser shall then be semipervious strata in the top stratum shall be set at lowered to the proper depth inside the hollow stem the bottom of the semipervious strata. and the filter sand placed. (A wire spider of design ap-(b) Piezometer materials. The N piezometers proved by the C.O.R. shall be attached to the bottom of shall consist of a 1.50-inch I.D. (Schedule 80) PVC the piezometer screen so as to center the piezometer screen with 0.025-inch slots connected to a 1.50-inch screen in the hole in which it is to be placed. Use two I.D. (Schedule 80) PVC riser pipe. The screens shall be crossed wires just above the plug in the tip.) Filter 10 feet long. The joints of the screen and riser shall be sand shall be poured down the hollow stem around the flush (inside and outside) and shall be glued together riser at a rate (determined in the field) that will ensure with PVC pipe cement. The filter sand (B) shall meet continuous filter sand flow down the hollow stem the specifications set forth for jet-eductor wells. De- around the riser and piezometer, and will keep the 8-pending upon the method of installation, the riser and inch hole below the auger filled with filter sand as the screens for the M, R, S, and T piezometers shall be as auger is withdrawn. Withdrawal of the auger and fill-specified above, or 1.5-inch galvanized iron riser pipe ing the space around the piezometer tip and riser with connected to a 1.5- by 30-inch self-jetting wellpoint filter sand shall continue until the hole is filled to a with a 30- to 40-mesh stainless steel screen. point about 5 feet above the top of the piezometer (c) Installation of piezometers. Holes for pie- screen. Above this elevation, the space around the zometers may be advanced by either: using an 8-inch riser pipe may be filled with any clean, uniform sand O.D. continuous flight auger with a 33/8-inch I.D. hol- with less than 5 percent passing a No. 100 U.S. Stand-low stem with the hollow stem plugged at the bottom ard sieve up to within 20 feet of the ground or exca-with a removable plug; augering and more or less vated surface. An impervious grout seal shall be placed simultaneous installation of a 6-inch casing; or using a around the top 20 feet of the ground or excavated sur-rotary wash drilling procedure (6-inch diameter) and face. An impervious grout seal shall be placed around an organic drilling fluid, such as Revert, if necessary, the top 20 feet of the hole for the M, R, S, and T pie-G-20
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 zometers, and 5 feet for the N piezometers. for the N piezometers. Samples shall be obtained using Method 2. Casing. The hole for a piezometer may a 13/8-inch (minimum) I.D. split-barrel or 3-inch Shelby be formed by setting a 6-inch casing to an elevation 1 tube sampler by driving or pushing. The length of to 2 feet deeper than the elevation of the piezometer drive or push shall not be less than 3 inches. If there is tip. The casing may be set by a combination of rotary insufficient sample recovery to identify the soil prop-drilling and driving the casing. The casing shall be erly, another sample shall be obtained immediately be-kept filled with water, or organic drilling fluid if low the missed sample. If desired, the sampler may be necessary, to keep the bottom of the hole from blow- advanced using driving jars on a wireline.
ing. After the casing has been set to grade, it shall be (d) Development and testing. After each pie-flushed with water or (clean) drilling fluid until clear zometer is installed, it shall be promptly flushed with of any sand. The piezometer tip and riser pipe shall clean water, developed, and pumped to determine if it then be installed and the filter sand poured in around is functioning properly. (If an organic drilling fluid has the riser at a rate (to be determined in the field) which been used, Johnsons Fast Break, or equivalent, shall will insure a continuous flow of filter sand down the be added in accordance with the manufacturers rec-casing that will keep the hole around the riser pipe and ommendations to break down the drilling fluid.) A 10-below the casing filled with filter sand as the casing is foot minimum positive head shall be maintained in the withdrawn without sand-locking the casing and riser piezometer following addition of the Fast Break. After pipe. (Placement of the filter sand and withdrawal of at least 30 minutes has elapsed, the piezometer shall the casing may be accomplished in steps as long as the be flushed with clear water and pumped. The piezom-top of the filter sand is maintained above the bottom eter may be pumped with either a suction pump or by of the casing but not so much as to sand-lock the means of compressed air. The approximate rate of riser pipe and casing.) Filling the space around the pie- pumping during development shall be measured. Pie-zometer tip and riser with filter sand shall continue zometers installed in the deep sand formation will be until the hole is filled to a point about 5 feet above the considered acceptable if they will pump at a rate of 2 top of the piezometer screen. Above this elevation, the to 5 gallons per minute or more. Piezometers installed space around the riser pipe may be filled with any in the semipervious strata within the top strata will be clean, uniform sand and the hole grouted as specified considered acceptable if they will pump at a rate of at in Method 1 above. least 0.5 gallon per minute, or when the piezometer is Method 3. Rotary. The hole for a piezometer may filled with water, the water level falls approximately be advanced by the hydraulic rotary method using half the distance of the groundwater table in a time water or an organic drilling fluid. The hole shall have a less than the time given below for various types of soil:
minimum diameter of 6 inches. After the hole has Approximate been advanced to a depth of 1 or 2 feet below the pie- Type of soil in Period of time of zometer tip elevation, it shall be flushed with clear which piezometer observation 50 percent fall water or clean drilling fluid, and the piezometer, filter screen is set minutes minutes sand, sand backfill, and grout placed as specified in Sandy silt (> 50% silt) 30 30 Method 2 above, except there will be no casing to pull. Silty sand (< 50% silt, > 12%
Method 4. Self-jetting. The M, R, S, and T piezom- silt) 10 5 Fine sand (< 12% silt) 5 1 eters may be drilled to within 4 feet of planned total depth, then clean water used to advance the self-jet- If the piezometer does not function properly, it shall be ting wellpoint to the design grade without the use of developed by a combination of air surging and pump-filter sand around the wellpoint. The seal and backfill ing with air as necessary to make it perform properly.
for the piezometers shall consist of a pumpable If the piezometer still will not perform properly, it cement-bentonite grout, with a ratio of 1 gallon of ben- shall be reinstalled at a nearby location selected by the tonite per bag of cement, or equivalent cement grout C.O.R.
approved by the C.O.R. (Only enough water shall be (e) Monitoring groundwater table. The Contrac-added to make the grout pumpable.) The tops of the tor shall read all M and N piezometers at least once a risers shall be cut off 36 inches above the ground sur- week, selected piezometers at least twice a week, some face. The upper part of the piezometer shall be pro- of the piezometers in the deep sand formation daily, tected by installing a 6-inch I.D. PVC or corrugated and the water level in the dewatering and the jet-educ-metal pipe around the riser cemented in to a depth of 3 tor wells at least once a week for his or her informa-feet below the ground surface. The number of the pie- tion and use in operation of the dewatering systems zometer shall be marked with 3-inch-high black letters and control of groundwater as specified. The Contrac-on the pipe guard around the riser pipe. tor shall record what deep well and jet-eductor wells Method 5. Sampling. Split-barrel samples shall be are being pumped when he takes his piezometer or obtained at 5-foot intervals and at every strata change water level readings. The C.O.R. will also read the M G-21
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC p-418 and N piezometers on a schedule similar to the above bowl. With approval of the C.O.R., the pump bowl may for his own check and evaluation purposes. be lowered. In order to maintain maximum well effi-(f) Records. The Contractor shall furnish copies ciency, the deep-well system shall be operated by of all piezometer and water level readings to the pumping whatever number of wells are required to C.O.R. within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of being taken. Copies of pie- achieve the specified water level lowering in the deep zometer, water level, and flow measurements made by sand formation without pumping any well more than the C.O.R. will be furnished to the Contractor within 1200 gallons per minute except in an emergency or if 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. required to achieve the specified water level lowering.
(3) Dewatering system flow. (4) Responsibility. Dewatering the excavation in-(a) Flow measurements. The flow from individ- cludes the control of seepage and artesian pressure in ual dewatering wells will be measured by means of a the deep sand stratum underlying the site and the con-pitometer installed in the discharge pipe from the trol of seepage from the upper silts and silty sand for well. As a check on the pitometer measurements and the duration of this contract. Included are the opera-on the performance of the well pump, the rate of flow tion and maintenance of the deep-well, jet-eductor being pumped will also be estimated from the pump well, and surface water control systems.
characteristic curve, engine speed, static lift of the (5) Repair and replacement. The specified number water, and the pressure in the discharge pipe at the of wells and pumps shall be available for use at all top of the well. Flow from the entire dewatering sys- times. All damaged or malfunctioning wells or well tem will also be measured by means of a pitometer. All components shall be repaired or renewed as expedi-flow measurements will be made by the C.O.R. as- tiously as possible while continuing to maintain the re-sisted by the Contractors dewatering engineer. quired water levels. The Contractor shall be responsi-(b) Frequency of measurement. The total flow ble for all replacement equipment and the repair and from the dewatering system shall be measured once or maintenance of all system components so as to main-twice a week and the flow from individual wells week- tain the system fully operational. Replacement equip-ly or biweekly, as appears appropriate. ment and materials shall conform to the requirements (c) Records. All flow measurements will be re- of these specifications.
corded by the C.O.R. and a copy of the data furnished (6) Maintenance criteria. The Contractor shall to the Contractor within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The C.O.R. will be maintain a regularly scheduled maintenance program responsible for reading the river gage and recording which shall conform with the equipment manufac-the data; a copy of the river gage reading will be fur- turers recommendations and include all other work nished to the Contractor each day. necessary to maintain all components fully operation-(4) Sanding. The flow from each dewatering well al. The maintenance program shall include, but not be will be monitored for sanding. The rate of sanding will limited to, checking the flow rate and water elevation be determined by taking a measured amount of water in each well. All data and records shall be submitted to being pumped from each well and the sand content de- the C.O.R. at the completion of this contract. The Con-termined. The maximum rate of sanding acceptable tractor shall also maintain any nonoperating pumps will be 5 parts per million. The rate of sanding will be and engines. Maintenance shall include, but not be checked once a week by the C.O.R. and the data re- limited to, starting each nonoperating pump and en-corded. A copy of the data will be furnished to the Con- gine on a weekly basis and operating the pump for a tractor within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. minimum of 15 minutes. All pumps, both operating
- i. Operation and maintenance of dewatering and and nonoperating, shall be tested for wear, independ-surface water control systems. ently, on a monthly basis. The Contractor shall con-(1) Supervision. Supervisory personnel shall be duct a shutoff head test and a test to verify that the present onsite during normal working hours and shall pump is capable of operating at its rated head capac-be available on call 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day, 7 days per week, in- ity. The Contractor shall renew all pumps having a cluding holidays. test result less than 75 percent of the manufacturers (2) Operating personnel. Sufficient personnel rated shutoff head or rated capacity. The maintenance skilled in the operation, maintenance, and replace- tests shall be conducted under the supervision of the ment of the dewatering and surface water control sys- Contractor Quality Control representative and under tems, components, and equipment shall be onsite 24 the observation of the C.O.R.
hours a day, 7 days per week, including holidays, at all j. Damages. The Contractor shall be responsible and times when the systems are in operation. shall repair without cost to the Government, any work (3) Well pumping restriction. The pumping rate of in place, another contractors equipment, and any any dewatering (deep) well shall be adjusted, if neces- damage to the excavation, including damage to the sary, by adjustment of engine speed or valving so that bottom due to heave that may result from his negli-the water level in no well is lowered below the pump gence, improper operation and/or maintenance of the G-22
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 dewatering system, and any mechanical failure of the for payment on the basis of each pump properly in-system. stalled and fully operational.
- k. Transfer of system. The succeeding Contractor (b) Payment at the contract unit price for instal-lation of dewatering turbine pumps, engines, and ac-for Phase III construction, or the Government, shall cessories shall constitute full compensation for fur-take title to the complete surface and dewatering sys-nishing all plant, labor, materials, and equipment for tems when the Contractor for Phase II completes his furnishing and installing the pumps and engines.
or her work. The facilities to be transferred include all (5) Standby turbine pumps.
dewatering wells, jet-eductor wells, pumps, engines, gear drives, piezometers, header pipe, valves, and all (a) Standby turbine pumps will be measured for payment on the basis of each complete pump placed on spare parts and standby equipment pertinent to the the jobsite.
surface and groundwater control systems. The de-(b) Payment at the contract unit price for fur-watering systems shall be continuously operated dur-nishing standby turbine pumps shall constitute full ing the transfer of the system to either the Phase III compensation for furnishing the pumps and placing in Contractor or to the Government. The (succeeding) appropriate storage. Each standby turbine pump shall Contractor for Phase III work, or the Government, include all components shown on the drawings includ-shall take title to the complete dewatering well, jet-ing, but not limited to, 130 feet of column pipe and eductor, and surface water control systems as installed shafting, pump bowls, suction pipe, pump head, gear when either assumes responsibility for maintaining drive, and flexible coupling.
the excavation dewatered. The Contractor (Phase II)
(6) Standby diesel power units.
shall not be responsible for removing any of the de-(a) Standby diesel power units will be measured watering systems or grouting of wells or supplemental for payment on the basis of each complete power unit dewatering facilities, if any, installed by him or her, at placed on the jobsite.
the end of his or her contract or subsequently there-(b) Payment at the contract unit price for fur-after.
nishing standby diesel power units shall constitute full
- l. Measurement and payment. compensation for furnishing all plant, labor, mate-(1) Unwatering Phase I excavation. rials, and equipment for furnishing the diesel engines (a) No measurement will be made for unwater- and placing in appropriate storage. Each standby die-ing Phase I excavation. sel power unit shall include all components shown on (b) Payment for unwatering Phase I excavation the drawings including the 110-horsepower diesel en-will be made at the lump sum price and shall consti- gine with clutch power takeoff and fuel tank.
tute full compensation for furnishing all plant, labor, (7) Well discharge header system.
materials, and equipment necessary to unwater Phase (a) No measurement will be made for the well I excavation. discharge header system.
(2) Surface water control and sump pumping. (b) Payment for the well discharge header sys-(a) No measurement will be made for surface tem will be made at the lump sum price and shall con-water control and sump pumping. stitute full compensation for furnishing all plant, (b) Payment for surface water control and sump labor, materials, and equipment necessary to install pumping will be made at the lump sum price and shall the system. The system includes, but is not limited to, constitute full compensation for furnishing all plant, header pipe, valves, fittings, outfall structures, and ac-labor, materials, and equipment for surface water con- cessories.
trol and sump pumping, regardless of the source of (8) Jet-eductor wells.
water. (a) Jet-eductor wells will be measured for pay-(3) Deep dewatering wells. ment by the linear foot to the nearest foot from the (a) Dewatering wells will be measured for pay- (berm) ground surface to the bottom of the PVC pipe ment on the basis of each well successfully completed as installed.
and accepted by the Government, (b) Payment at the contract unit price for instal-(b) Payment at the contract unit price for instal- lation of jet-eductor wells shall constitute full compen-lation of dewatering wells shall constitute full compen- sation for all plant, labor, header pipe, pumps, engines, sation for furnishing all plant, labor, materials, and tanks, valves, connections, materials, and equipment equipment for performing all operations necessary to for performing all operations necessary to install the install, develop, and test pump each well. jet eductors and pumping system as shown on the (4) Dewatering turbine pumps, engines, and acces- drawings.
sories. (9) Piezometers.
(a) Dewatering turbine pumps, engines, and ac- (a) M, R, S, T, and N piezometers will be meas-cessories as specified on the drawings will be measured ured for payment on the basis of each piezometer suc-G-23
TM 5-815-5/AFM 88-5, Chap 6/NAVFAC P-418 cessfully installed and tested. system required).
(b) Payment at the contract unit price for instal- (b) Drawings showing the soil conditions, strati-lation of M, R, S, and T piezometers shall constitute fication, and characteristics; location and size of full compensation for furnishing all plant, labor, mate- berms, ditches, and deep wells; piezometers, well-rials, and equipment for performing all operations points; and sumps and discharge lines or ditches.
necessary to install, develop, and test the M, R, S, and (c) Capacities of pumps, prime movers, and T piezometers. standby equipment.
(c) Payment at the contract unit price for instal- (d) Design calculations including design param-lation of N piezometers shall constitute full compensa- eters and basis of such parameters, factors of safety, tion for furnishing all plant, labor, materials, and characteristics of pumping equipment, piping, etc.
equipment for performing all operations necessary to (e) Detailed description of procedures for in-install, develop, and test N piezometers. stalling, maintaining, and monitoring performance of (10) Testing, operation, and maintenance of de- the system.
watering systems. (2) Notice to Proceed issued by Engineer or re-(a) No measurements will be made for testing, ceipt of the dewatering plans and data submitted by operation, and maintenance of the deep-well and jet- Contractor shall not in any way be considered to re-eductor well systems. lieve the Contractor from full responsibility for errors (b) Payment for testing, operations, and mainte- therein or from the entire responsibility for complete nance of the dewatering systems as specified will be and adequate design and performance of the system in made at the lump sum price and shall constitute full controlling the groundwater in the excavated areas.
compensation for the duration of this contract and un- The Contractor shall be solely responsible for proper til the systems are transferred to the Phase III Con- design, installation, operation, maintenance, and any tractor or the Government. failures of any component of the system.
(3) The Contractor shall be responsible for the ac-G-7. Example of type B-3 specifications curacy of the drawings, design data, and operational (dewatering). records required.
- a. General.
(1) The dewatering system shall be designed by c. Damages. The Contractor shall be responsible for the Contractor using accepted and professional and shall repair without cost to the Owner any damage methods of design and engineering consistent with the to work in place, other Contractors equipment, util-best modern practice. ities, residences, highways, roads, railroads, private (2) The dewatering system shall be of sufficient and municipal well systems, and the excavation, that size and capacity as required to control ground and may result from his or her negligence, inadequate or surface water flow into the excavation and to allow all improper design and operation of the dewatering sys-work to be accomplished in the dry. tem, and any mechanical or electrical failure of the de-(3) The Contractor shall control, by acceptable watering system.
means, all water regardless of source and shall be fully d. Maintaining excavation in dewatered condition.
responsible for disposal of the water. The Contractor Subsequent to completion of excavation and during shall confine all discharge piping and/or ditches to the the installation of all work in the excavated area, the available easement or to additional easement obtained Contractor shall maintain the excavations to a de-by the Contractor. All necessary means for disposal of watered condition. System maintenance shall include the water, including obtaining additional easement, but not be limited to 24-hour supervision by personnel shall be provided by the Contractor at no additional skilled in the operation, maintenance, and replace-cost to the owner. ment of system components, and any other work re-
- b. Design. quired to maintain the excavation in a dewatered con-(1) Contractor shall obtain the services of a qual- dition. Dewatering shall be a continuous operation and ified dewatering Expert or a firm to provide a de- interruptions due to outages, or any other reason, shall tailed plan for dewatering the excavation. Contractor not be permitted.
shall submit his or her dewatering plan to the Engi- e. System removal. The Contractor shall remove all neer for review and approval. The material to be sub- dewatering equipment from the site, including related mitted shall include, but not be limited to, the follow- temporary electrical service. All wells shall be re-ing: moved or cut off a minimum of 3 feet below the final (a) The qualifications and experience of the se- ground surface and capped. Holes left from pulling lected dewatering Expert or the firm (minimum of 5 wells or wells that are capped shall be grouted in a years of proven experience in the design of equivalent manner approved by the Engineer.
G-24
TM 5-818-5/AFM 88-5, Chap 6/NAVFAC P-418 The proponent agency of this publication is the Office of the Chief of Engineers, United States Army. Users are invited to send com-ments and suggested improvements on DA Form 2028 (Recom-mended Changes to Publications and Blank Forms) direct to HQDA (DAEN-ECE-G), WASH DC 20314.
By Order of the Secretaries of the Army, the Air Force, and the Navy:
JOHN A. WICKHAM, JR.
General, United States Army Official: Chief of Staff ROBERT M. JOYCE Major General, United States Army The Adjutant General CHARLES A. GABRIEL, General, USAF Official: Chief of Staff JAMES H. DELANEY, Colonel, USAF Director of Administration W. M. ZOBEL Rear Admiral, CEC, U.S. Navy Commander, Naval Facilities Engineering Command Distribution: