ML23157A330

From kanterella
Jump to navigation Jump to search
Hermes CP Doc - Hermes CP Audit Questions 82-86 and 92-94 for Preliminary Safety Analysis Report Section 4.5 and Chapter 13
ML23157A330
Person / Time
Site: Hermes File:Kairos Power icon.png
Issue date: 06/06/2023
From:
NRC
To:
NRC/NRR/DANU
References
Download: ML23157A330 (5)


Text

From:

Samuel Cuadrado de Jesus Sent:

Tuesday, June 6, 2023 5:42 PM To:

KairosPower-CPDocsPEm Resource

Subject:

Hermes CP Audit Questions 82-86 and 92-94 for Preliminary Safety Analysis Report Section 4.5 and Chapter 13 Attachments:

Audit Questions 82 to 86 and 92 to 94_Redacted.pdf Samuel Cuadrado de Jesús Project Manager Advanced Reactor Licensing Branch (UARL)

Division of Advanced Reactors and Non-Power Production and Utilization Facilities (DANU)

U.S. Nuclear Regulatory Commission Phone: 301-415-2946 Samuel.CuadradoDeJesus@nrc.gov

Hearing Identifier:

KairosPower_CPDocs_Public Email Number:

41 Mail Envelope Properties (SA1PR09MB73928A6A433E191672B349C58852A)

Subject:

Hermes CP Audit Questions 82-86 and 92-94 for Preliminary Safety Analysis Report Section 4.5 and Chapter 13 Sent Date:

6/6/2023 5:42:09 PM Received Date:

6/6/2023 5:42:13 PM From:

Samuel Cuadrado de Jesus Created By:

Samuel.CuadradoDeJesus@nrc.gov Recipients:

"KairosPower-CPDocsPEm Resource" <KairosPower-CPDocsPEm.Resource@nrc.gov>

Tracking Status: None Post Office:

SA1PR09MB7392.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 333 6/6/2023 5:42:13 PM Audit Questions 82 to 86 and 92 to 94_Redacted.pdf 89226 Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Hermes Construction Permit Application Audit Audit Questions for Preliminary Safety Analysis Report Section 4.5 and Chapter 13 82 (MHA)

MHA tritium release PSAR Section 13.2.1.1 seems to refer to TF while the MST refers to T2. Please clarify.

83 MHA tritium release PSAR Section 13.2.1.1 states "The tritium transport through the graphite pores is assumed to be instantaneous, and all graphite grains are exposed to the same tritium uptake conditions. Is the tritium in the graphite grains diffused out using the diffusivities given on page 47 of 138 of the MHA calc?

84 MHA tritium release What is the reference or basis for these tritium graphite uptake and release model inputs?

85 MHA tritium release Is the graphite perfect absorber true of the pebbles and structural graphite?

86 MHA tritium release Is all the retained tritium of the pebbles released in the ((

))?

92 PHSS Accident For the PHSS accident, the oxidation mass loss rate is given by equation 23 in KP-TR-018. The correlation by Zhou is said to be from Reference 23 but I cant find that

correlation (Zhou) in Reference 23 (MELCOR liftoff model). Is Reference 23 the correct reference?

93 Section 13.1.6 Need an audit call regarding the statement in 13.1.6, Limiting the amount of MAR in subsystems and components obviates the need for a more detailed safety analysis for this category of events.

Does this statement mean for the CP or does it also apply to the OL? The statement sounds like a design commitment as the various MARs are not yet determined. Its the staff opinion this will need to be evaluated at the OL to ensure the MHA continues to bound the releases associated from all non-safety systems due to a single initiating event (e.g., seismic).

This would require some type of evaluation (safety-analysis) that the subsystem MAR amounts are set correctly and a summary of this evaluation described in the OL application. Therefore, the wording obviates the need for a more detailed safety analysis is difficult to understand.

94 MHA I need a clarification from Kairos re. the MHA fuel RN release. Per the MHA calc ((

)), the fully RN inventory of the fuel is retained and hence the fuel source term is independent of pre-transient, in-service failures or manufacturing defects.

1. Does Inservice Failures in Figure 3.1 of the MHA calc mean a TRISO failure (i.e., complete failure of all coating layers)?
2. Does the MHA transient assume a bounding combination of in-service (pre-transient) and manufacturing defects by cohort type?
3. Are the MHA assumed in-service failures (pre-transient) by cohort compared against the steady-state (pre-transient) KP-BISON results to ensure they are conservative?