1 Paga 1

of 32 NPPD Cooper Nuclear Station Unit il Coseercial Service Date July 1974 National Board 820762

)

NIS-1 FORM

.(

OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. OWNER:

Nebraska Public Power District, PO Box 499, Columbus, Ne 68601

2. PLANT:

Cooper Nuclear Station #1, PO Box 98, Brownville, NE 68321 3.

PLANT UNIT:

  1. 1 4.

OWNER CERTIFICATE OF AUTHORIZATION (if required): N/A J

5. COMMERCIAL SERVICE DATE:

07/74 6.

NATIONAL BOARD NUMBER FOR UNIT: #20762

7. COMPONENTS INSPECTED:

See Attached Exam Component ID Index

8. EXAMINATION DATES: 03-21-89 TO 06-17-89 9.

INSPECTION INTERVAL: From 1985

~~ To 1FFT f

10. ABSTRACT OF EXAMINATIONS:

For a list of examinations see attached Exam Component ID Index.

Current status of work required for current interval is 45% complete this date.

11. &BSTRACf OF CONDITIONS NOTED:

See Attached Report Summary

12. ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN:

See attached Report Bummary We certify that the statements made in this report are correct and the examinations and corrective m Asures taken conform to the rules of the ASME Code,Section XI.

/

/

( ato 2

1989 Signed en nm.-

'D{v3sionManager Certificate of Authorization No. (if applicable)

MS Expiration Date Md CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holdin a valid commission issued by the National E ard of Boiler and Pressu a g u Inspectors and/or @e State or Province of a

O.

of L7*

have inspectec1 A M and employed by H501 copponepts described in this owner's Data Report during the period 3-2l-oY to b-O-M1, and state that to the best of my knowledge and belief, the Owner has parformed examinations and taken corrective measures desribed in this Owner's Data Report in accordance with the requirements of the ASME Code,Section XI.

By the signing of this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Data Report.

Furthermore, naither the Inspector nor his employer shall be liable in any manner for any psrsonal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 9 1989 b)~

Commisions k%&33 Base 433 i

l Inspector's Signature National Board, State, Province and No.

k 8909260043 890913 PDR ADOCK 0S000298 G

PNV

7

/'

M l

s' Page 2

of 32 NPPD Cooper Nuclear Station Unit 1

(

Commercial Service Date: July 1974 National Board Number: 20762 REPORT

SUMMARY

1.0 Introduction l

Nondestructive Examinations were performed by GE Inspection Services of GE Nuclear Energy at Cooper Nuclear Station Unit 1 under contract No. 86A-MS2 Tasks 161 and 176 by Nebraska Public Power District.

The examinations were performed during the periods of March 21, 1989 through June 17, 1989.

A total of 616 components were examined during this period.

The total includes ASME Section XI Components, Erosion / Corrosion Thickness Measurements, Augmented Inservice Inspections, and Support Modifications.

2.0 Summary of Components Inspected The following table lists the components examined and describes indications and/or deficiencies which were recorded.

ASME Number of Category Components Description Conditions Noted

(

B-A 4

RPV Velds No Recordable Indications (MRI)

HHE-BB-4 EDS 8242 for Scan Limitations HME-BB-6 DS 8227 for Scan Limitations -

3 B-D 11 Nozz to Vessel Veld NVE-BD-N2E. EDS 1215 - Laminar, Acceptable HE-BD-N2J DS #140 - for Scan Limitations, NRI NE-BD-N2K DS 1140 - for Scan Limitations, NRI N E-BD-lMA DS 1130 - Laminar, Acceptable H IR-BD-N4A EDS 8168 - for Scan Limitations, NRI W IR-BD-N4B EDS 1180 - for Scan Limitations, NRI W IR-BD-N40 EDS #170 - for Scan Limitations, NRI W IR-BD-N4D EDS #182 - for Scan Limitations, NRI

' All Other Items = NRI B-F 3

Class I Dissimilar See Automated Ultrasonic Inspections on Page 5 Metal Velds of Report Suasary B-G-2 1

Class I Pressure NRI Retaining Bolting Less Than 2' Dia.

B-H 4

Integral Attachments EPV-BH-1 EDS 6053 for Limitations, NRI for Vessels EPV-BH-4 ' DS 6054 for Limitations, NRI

\\

+

B-J 13 Class I Pressure TVB-BJ-111 EDS 1102 & 100 for Scan Limitations, El k

Retaining Piping TVD-BJ-111 EDS #109 & 111 for Scan Limitations, NRI All Other items NRI

,v p

m s;

o

-Page 3

of 32 ll Q.

NPPD Cooper Nuclear Station Unit 1 Coseercial Service Date: July 1974 l

National Board Number: 20762 1

REPORT

SUMMARY

(cont'd) i :.-

AS?E Number of l

Category Cosponents Description Conditions Noted B K-1 14 Class ! Integral MSC-BK1-12 EDS 8367 for Limitations, NRI Attachments MSC-BK1-20 EDS 8369 for Limitations, NRI MSD-BK1-11 EDS 4323 for Limitations, NRI All Other itees

  • NRI B-N-1; 11-Interior of RPV See List of VT Inspections on Page 5 & 6 of Report Suasary B-P

-2

. Pressure Retaining Performed to CNS Procedure 2.1.14 Acceptable Components C-A

-1 Heat Exchanger Velds RHR-CA-2A EDS 8287 for Scan Limitations, NRI C-C.

42 Class 11 Integral RHB-CEl-4' EDS 8197 Linear Indication Removed by

(

Attachments Additional Veld Prep. Ref. EDS 8412 i

PSA-CEl-4 DS 4081 & 276 RejectableIndication, Repaired Per VI 89-2658 Note: This Ites Determined to be Non Section XI RHB-CC-51 EDS 9069 Linear Indication Removed by Additional Veld Prep. Ref. EDS 1282 All Other Itees : NRI C-F 29 Class 11 Pressure RBV-CT-79 DS 4261 for Scan Limitation, NRI Retaining Piping RHD-CF-9 EDS 1156 for Limitation, NRI PSA-CF-12 EDS 8049 Linear Indications Removed by Additional Veld Prep. Ref. EDS #281 PSA-CF-9 EDS 1162 Geometry RAS-CF-28 EDS 1220 for Scan Limitation, NRI RHE-CF-19 EDS #187 Geometry RCT-CF-9 EDS 8096 Linear Indications Removed by Additional Weld Prep. Ref. EDS #283 All Other Itees : NRI T-A 7

Plate & Shell Supports NRI T-B 23 Linear Type Supports NRI F-C 69 Component Standard Supports MSS-16 EDS #316 6 317 Modified Dr. der DC 88-302 Aand 2 EDS 8432 & (33 Reexamined

l e

.J Page 4

of 32 NPPD Cooper Nuclear Station Unit 1 1

!' (-

Coseercial Service Date: July 1974 National Board Number: 20762 j

REPORT

SUMMARY

(cont'd)

AUGMENTED INSERVICE INSPECTIONS Number of Description Components Conditions Noted UT OF RING GIRDER BOLTING 19 NR1 UT OF RING GIRDER ARCHOR BOLTING 36 NRI NRC BULLEf!N 88-01 EKANINATIONS 71 RVCU-B - DS 8193 For Scan Limitation RWCU-10 DS #166 Root Geometry RVCD-13 EDS 4119 Rejected DS 8294 Accepted RUCU-14 DS #119 Root Geometry RWCU-V7 EDS #292 New Weld RWCU-V8 DS 8292 Nes Veld RWCD-26 DS 8086 Rejected EDS 4302 Accepted RWCU-29 EDS 8037 Root Geometry RWCD-29A DS 6037 ID & OD Geometry EVCU-31 EDS 6035 Root Geometry RVCU-35 DS 4035 Root Geometry RWCU-36 DS 4033 Root Geometry RFCU-37 DS 6033 Root Geometry RWCU-40 DS 6031 Root Geometry RfCU-41 DS 8031 Root Geometry RWCD-42 EDS 6031 Root Geometry RWCU-44 EDS 8027 Root Geometry RWCU-45 DS 9027 Root Geometry RUCU-46 EDS 8027 Root Geometry RWCU-47 EDS 4027 For Scan Lieltation RWCU-48 EDS 8021 Root Geometry RVCD-49 DS 8021 Root Geometry RfCU-52 EDS 8117 Root Geometry CVB-BF-8 G S 8021 For Sean Limitation CVA-CF-30A EDS 4058 Counter Bore Ind.

CVA-CF-40 EDS 8113 Rejected EDS 8207 New Weld CVA-CF-42 Veld Cut Out EDS 8207 New Veld CVA-CF-43 EDS 9098 Rejected EDS #207 New Veld CWA-CF-44 EDS #113 Rejected EDS 8207 New Veld CVA-CF-39A EDS 8292 New Veld All Others = NEI

(

NRC BULLETIN 88-08 EXAMINATIONS 6

FWA-BJ-1 EDS 4029 Honplanar, Acceptable FFA-BJ-2 EDS 4025 Root Geometry All Others = NRI UT OF SHROUD EEAD BOLTING 36 fra cracted bolts (110 6 11) EDS 6093 m_______________._.____________

(Rajlaced with new bolts)

Page 5

of 32 NPPD Cooper Nuclear Station Unit 1 l

Commercial Service Date July 1974 National Board Number 10762 i

REPORT

SUMMARY

(cont'd)

AUCMEInw INjERVICE INSPECTIONS Number of Description Components Conditions Noted UT FOR EVIDENCE OF EROSION / CORROSION 39 RHR Valve M027B Valve Has Been Derated (69 EXAMS)

EDS #EC-026 Below Minimum Wall Thickness Service Water Valve M089A Valve Has Been Derated EDS #EC-079 Below Minimum Wall Thickness EDS #EC-107 Repaired Area RHR Valve M034A Valve Has Been Derated EDS #EC-103 Below Minimar. Wall Thickness RHR Valve M027A Valve Has Been Derated EDS #EC-105 Below Minimum Wall Thickness EDS #EC-105A Rescan of Area After Excavation Core Spray Valve M026B Valve Has Been Derated EDS #EC-115 Below Minimum Wall Thickness All Others Above Minimum Wall Thickness Requirements AU10 MATED ULTRASONIC INSPECTIONS 3

CSA-BF-1 EDS #AD-002 Non-Relevant Indications, Acceptable RRJ-BF-1 EDS #AD-003 Non-Relevant Indicar. ions, Acceptable RRK-BF-1 EDS #AD-001 Non-Relevant Indications, Acceptable VI OF CORE SFRAY SPARGERS AND 8

Inspection Also Included "11' Boxes, Acceptable INTEPJIAL PIPINC VT OF FEEDWATER SPARCERS AND 12 Acceptable FEEDWATER SPARCER BRACKETS End Bracket at 17h*, Tack Weld on End Bracket Pin is Inaccessible, Pin Appeared Normal End Bracket at. 265', Tack Weld on End Bracket Pin is Inaccessible, Pin Appeared Normal End Bracket at 275', Tack Weld on End Bracket Pin is Inaccessible, Pin Appeared Normal VI 0F FEEDWATER N0ZZLE INNER RADIUS 4

Acceptable VT OF JET PUMPS 6

Pumps 1, 2, 3, 4, 9, and 10 Inspected Pumps 1, 2, 9, and 10 Have Additional k'adges Pumps 1, 2, 3, and 4 Seating of Rams Head and Set Screw Tack Welds Were Not Inspected VI C1 DRYER 1

Acceptable VI 0F PLATE BOLTS 1

Acceptable l

1

i-Page 6

of 32

~

NPPD Cooper Nuclear Station Unit 1

(

Coseercial Service Date: July 1974 National Board Number: 20762 REPORT

SUMMARY

(cont'd)

AUGMENTED INSERVICE INSPECTIONS Number of Description Components Conditions Noted' VT OF STEAM SEPARATOR 1

Peripheral Tie Bars Only, Acceptable VT OF SHROUD HEAD ASSEMBLY 1

Acceptable VT OF SURVEY SAM KES 2

Acceptable VT OF TOP CUIDE HOLD D0VN 4

Acceptable VT OF BELTLINE VELD AREAS 1

Acceptable UT OF SHROUD MANWAY ACCESS 2

DS #R-001 Non-Relevant Indications, COVERS Acceptable VT OF SUPPORT MODIFICATI0E 169 RH-H132 DS 8120 Loose Nut DS #448 Accepted

(

SV-H84 EDS 8137 Loose Hut DS #448 Accepted HP-H31 DS #236 Modified by DC 88-302 EDS #448 Accepted E-H101A EDS #317 Nonrelevant Discontinuities DS 6448 Accepted CS-H19A DS #258 Modified by DC 88-302 DS 6417 Accepted CRD-BBS ES #250 Modified by DC 88-302 DS #448 Accepted E-517 DS 8424 No Movement in Strut 25 0453 Accepted E-H113 DS 8275 Replaced Vith Rigid Strut SV-H50 DS 4410 Loose Nut DS #417 Accepted SV-S23 DS #421 Modified by DC 88-302 DS 4455 Accepted E-S75 DS 4435 No Movement in Strut DS I453 Accepted HP-E23 DS #439 No Movement in Strut EDS #453 Accepted All Others = NRI EXTRA EXAMS 5

EH-97 DS 8372 Incorrect Setting Repaired Per VI 89-2798 (Non-Scheduled Component)

RHH-136 DS 8390 & 391 Loose Nut and Incorrect

(

Setting Repaired Per VI 89-2727 (Non-ScheduledComponent)

SSB-3 DS 6388 DS 4389 Acceptable RHH-15 DS 4124 Acceptable j

j PMC-CG-5 DS 6075 NRI

__A

l ISI BM C090EMT IIDEI C00NRNUCLEARSTATID SPRIK 1999 Page 1 of 32 Revision No. 1 I

EDS8 CDS4 LDSt RENARIS ASNE EXAE C00 0NENT DRAVIBG/

SIZE CORF.

CE CAL, PROCEDURE REV.

EXAM CAT.

1.D. NUMBER ISOMETRIC STD. 90.

NMBER TYPE B-A ME-BB-3 26 218' TD-R CNS. CAL.STD. MIUV-V812 2

UT-0 242 241 240 N0.15 UT-45 245 244 253 l

UT-60 248 047 246 ME-BB-4 26 21B' THD-N CRS. CAL.STD. MIUV-VB12 2

Uf-0 242 241 240 NO.15 i

0T-45 245 244 243 Uf-60 248 247 246 HE-BB-5.

26 218' TED-R CNS. CAL.STD. HIUV-V812 2

UT-0 227 226 225 N0.15 U7-45 230 229 228.

Uf-60 233 232 231 ME-BB-6 I 26 218' TED-N CNS. CAL.STD. MIUV-VB12 2

UT-0 227 226 225 B0.15 UT-45 230 229 228

. ('

UT-60 233 222 231 t

l p

s ic

ISI EIM f.2POREET INDEI COOPER M CLEAR STATI C L

+

SPRI N 1989 Page 1 of 32 Revision No. 1 C.

1; ASME EXAM COMP 0 E NT DRAVING/

SIZE CONF.

CNS CE.

PROCEDURE EV.

EKAM EDSI CDSI LDSt REMARKS CAT.

I.D. NUMBER ISOETRIC STD.110.

NUMBER TYPE l

l B-D RVE-BD-N2E 27 12' N-VE CBS.CE.STD.

MIUV-V812 2

UT-0 215 214 213 l

N0.16 l

UT-45 218 217 216 UT-60 212 211 210 NVE-BD-N2J 27 12' N-VE CNS.CE.STD.

MIUV-V812 2

UT-0 140 139 138 N0.16 07-45 143 142 141 UT-60 146 145 144 NVE-BD-N2K 27 12' N-VE CNS.CE.STD.

MIUV-V812 2

UT-0 140 139 138 NO.16 UT-45 143 142 141 UT-60 146 145 144 NVE-BD-N4A 27 12' R-VE CRS.CE.STD.

EIUV-W812 2

UT-0 130 129 128 NO.16 UT-45 133 132 131 i

UT-60 136 135 134 WID-BD-E2J 27 12' EIR CNS. CAL.STD.

NIRZ1-W812 1

ZOE 1 349 347 347 110.22 NIRZ2-V812 2

ZOE 2 345 343 343 CNSCESTD.25 NIRZ3-VB12 1

ZONE 3 341 339 338 NVlR-BD-N2K 27 12' RIE CNS. CAL.STD. !'IRZ1-V812 1

ZONE 1 350 347 347 NO.22 NIRZ2-VB12 2

ZOE 2 346 343 343 CRSCALSTD.25 NIRZ3-W812 1

ZONE 3 342 339 338 WIR-BD-54A 27 14' RIR CNS.CE.STD. NIRZ1-VB12 1

ZOE 1 168 167 167 NO.22 NIRZ2-V812 2

ZOE 2 173 172 172 CNSCESTD.27 NIRZ3-V812 1

ZOE 3 179 178 177 NVIR-BD-N4B 27 14' RIE CNS.CE.STD. NIk21-V812 1

ZOE 1 if9 167 167 N0.22 NIRZ2-V812 2

ZOE 2 174 172 172 CRSCALSTD.27 N1RZ3-V812 1

20E 3 180 178 177 '

("

WIR-BD-N4C 27 14' III CRS.CE.STD. NIRZ1-V812 1

ZOE 1 170 167 167 N0.22 NIRZ2-V812 2

ZOE 2 175 172 172

{

CISCALSTD.27 NIRZ3-V812 1

ZOE 3 181 178 177 3 -i

l e-ISI IIAN CORPORBRf IEEI 1 -

4 C00NRBOCLEARSTATIID 1

SPRIN 1989 Page 1 of 32 Revision No. 1

('

ASME EXAH COMPONENT DRAVIM/

SIZE CONF.

CNS CAL.

PROCEDUPI ;, REV.EXAM EDSt CDSt LDSt REMARKS CAT.

1.D. NUMBER ISOMETRIC STD. N0.

MMBER TYPE L

B-D NVIR-BD-MD 27 14' NIR CNS. CAL.SID. NIRZ1-V812 1

ZONE 1 171 167 167 N0.22 NIRZ2-V812 2

ZONE 2 176 172 172 l'

CkSCALSTD.27 NIRZ3-V812 1

ZONE 3 182 176 177 NVIR BD-N2E 27 12' NIR CNS. CAL.STD. NIRZ1-V812 1

ZONE 1 348 347 347 N0.22 NIRZ2-V812 2

ZONE 2 344 343 343 CNSCALSTD.25 NIRZ3-W812 1

ZONE 3 340 339 338

(

1

e ISI RM CORPORBf IDH Coont WCIBR 85712 SPRI J 1909 Page 10 of 32 Revision Bo. 1

~

ASME

'EIAM CORPONENT DRAVIM /

SIZE CONF.

CNS CAL.

PROCEDURE REV.

HAM EDSI CDS4 LDS4 RERARKS' if-

' CAT..

1.D. HMBER IS0 METRIC STD. N0.

NUSER TYPE Pa B-F CSA-BF-1 CNS-CS-4 13.4' SE-N N/A IP-V812 1

PT 048 CNS-51-13 HIUP-VB12 1.

UT 0 E-410 E-409 N-330 FALL 1984 1.125-SS OUTAGE CNS-61-13 UT-51 FRR 2 3

UT

.884-C5 45 RL AD-002 AC-010 A-001 4-22-89 CNS-51-13 UT-51 FRR 2 3

UT 1.125-SS 45 RL AD-002 AC-011 A-001 4-24-89 CNS-61-13 UT-51 FRR 2 3

UT

.844-CS 60 RL AD-002 AC-012 A-001 4-25-89 CNS-51 13 UT-51 FRR 2 3

Uf 1.125-SS 60 RL AD-002 ACt013 A-001 4-25-89 CNS-61-13 UT-43 FRR 1 10 UT

.844-CS 45 S AD-002 AC-014 A-001 4-26-89 CNS-51-13 Uf-43 FRR 1 10 UT 1.125-55 45 S AD-002 AC-015 A-001 4-26-89 AC-16A 4-27-89

L' 151545 COMP 0EM IEDE

  • l C00PR 50 CLEAR ST&f!']

SPRI N 1989 Page 11 of 32 Revision No. 1 ASME EXAM COMP 0ENT DRAVI E /

SIZE CONF.

CNS CAL.

PROCEDURE REV.

EXAM EDSt CDSt LDSt REMARS CAT.

I.D. NUMBER ISOETRIC STD. NO.

NUMBER TYPE B-F RRJ-BF-1 CNS-RE-37 14' SE-N N/A IP-V812 1

Pt 183 CNS-52-14 EIUP-V812 1

UT 0 E-410 N-409 N-330 FALL OUTAGE l,

140-SS 1984 CNS-60-14 UT-51 FLR 2 3

Uf

.972-CS 45 S AD-003 AC-016 A-001 4-28-89 CNS-52-14 UT 43 FRR 1 10 UT 140-SS 45 S AD-LJ3 AC-017 A-001 4-28-89 CNS-52-14 UT-51 FRR 2 3

UT 140-55 45 RL AD-003 AC-018 A-001 4-29-89 CNS-60-14 UT-51 FRR 2 3

UT

.972-C5 45 RL AD-003 AC-019 A-001 5-2-89 CNS-52-14 Uf-51-FRR 2 3

UT 140-55 60 RL AD-003 AC-020 A-001 5-2-89 CNS-52-14 UT-51 FRR 2 3

UT 140-SS 60 RL AD-003 AC-021 A-001 5-3-89 CNS-60-14 UI-51 FRR 2 3

UT

.972-CS 60 RL AD-003 AC-022 A-001 5-3-89

-+

ISI EIAH COEPORE! IEEI

=*-

COOPER WCLEAR STAT 1 ] -

SPRI N 1989 Page 12 of 3_2_

2 Revisionllo. 1

.(

'ASME EIAM COMPONENT' DRANING/

SIZE CONF.

CNS CAL.

PROCEDURE REV.

EXAR EDSt CDSt LDSt RENARKS CAT. -

I.D. NUMBER ISOMETRIC STD. NO.

NUMBER ffPE B-F F1K-BF-1 CNS-RR-37 14' SE-N N/A IP-VB12 1

PT 125 1

CNS-52-14 MIUP-V812 1

UT 0 N-410 N-409 N-330 FALL OUTAGE 140-S5 1984 CNS-60-14 UI-51 RR 2 3

UT

.972-CS 45 RL AD-001 AC-001 A-001 4-15-89 CNS-60-14 UT-51 RR 2 3

UT

.972-CS 45 RL AD-001 AC-002 A-001 4-17-89 CNS-52-14 UT-51 RR 2 3

UT 140-SS 45 RL AD-001 AC-003 A-001 4-17-89

(.

CNS-60-14 Uf-51 RR 2 3

UT

.972-CS 60 RL AD-001 AC-004 A-001 4-18-89 CNS-52-14 UT-51 FRR 2 3

UT 140-SS 60 RL AD-001 AC-005 A-001 4-18-89 i

CNS-52-14 UT-51 FRR 2 3

UT 140-S5 60 RL AD-001 AC-006 A-001 4-19-89 i

l CNS-60-14 UT-51 RR 2 3

UT

.972-CS 60 RL AD-001 AC-007 A-001 4-19-89 l

i I

l 1

CNS-52-14 UT-43 FRR 1 10 UT j

140-SS 45 S AD-001 AC-008 A-001

,4-19-89

)

(~

CNS-60-14 UT-43 RR 1 10 UT

.972-CS 45 S AD-001 AC-009 A-001 4-20-89

u;

. !$1 5 5 CCE N B E! IE EX C00NR WCLut STATID SNIJ 1989 Page 13 of 32 Revisionlio,,,I__

~(

ASME^

EXAE C0pONEllf M AVI N/

SIZE CONF.

CBS CAL.

PROCDURE REV.

EXAM EDSI CDS4 LDSt REllhRKS CAT.

I.D.IMIBER ISOMETRIC STD. 50.

MilBER TYPE B+2.

RHD-BG2-2 2510-5 E/A BLY.

N/A '

IV1-#812 3

V7 381 6>

j L(i l

t 1

l l

l 1

.l I

e

{'

i

i ISI IIM CONMEBf IEEI i

COOPER WCLEAR STAf!".]

SPRIN 1989 Page 14 of 32 Revision No. 1

~ -

ASME' EXAM COD ONENT DRAVIN/

SIZE CONF.

CE CAL.

PROCEDURE REV.

EIM EDSI CDS4 LDSt REMAKS CAT.

I.D. HMBER IS0 METRIC STD. NO.

HMBER f!PE B-H RPV-BH-1 27 218' VE-SS IP-UB12 1

PT 053 EPV-BH-4 27 218' VE-SS IP-W812 1

PT 054 RPV-BH-THD4 THD-LL MIEN-V812 1

MT 253 238 RPV-BB-THD2 THD-LL MIMSN-W812 1

MT 254 238

, {;

4D k6 f

l L.

18! BAM CORPOM E INDU C00P R BOCLEAR STATII]

SPRING 1989 Page 15 of 31 RevisionNo._l,

)

'(.

ASME EIAM COMPONENT DRAVING/

SIZE CONF.

CBS CAL.

PROCEDURE REV.

EKAN EDSI CDSI LDSt REMARKS CAT.

I.D. NUMBER ISOMETRIC afD. NO.

HUMBER TIPE l

i(

B-J FWA-BJ-111 2509 1 12' H-SE MIMSN-VB12 1

MT 083 082 CNS-GE-14-160-C MIUP-V812 1

UT 0 102 101 004 UT 45 100 099 003 FVB-BJ-111 2509 12' N-SE MIEN-V812 1

RT 084 082 CBS-GE-14-160-C MIUP-V812 1

UT C 102 101 004 Ut 45 100 099 003 FVC-BJ-111 2509-2 12' H-SE MINSN-V812 1

MT 104 103 CNS-CE-14-160-C MIUP-V812 1

UT 0 109 108 004 UT 45 111 110 003 FVD-BJ-111 2509-2 12' N-SE HIMSN-V812 1

MT 105 103 CNS-GE-14-160-C MIUP-VB12 1

UT 0 109 108 004 UT 45 111 U

,903 b,

HSA-BJ-2 GE731E611 24' P-E MINSN-V812 1

MT 008 007 "

CNS-106-24 MIUP-V812 1

VT 0 062 061 004 UT 45 045 044 001 MSA-BJ-2A GE731E611 24' IA MIMSN-V812 1

MT 009 007 CNS-106-24 MIUP-V812 1

UT 0 062 061 004 UT 45 045 044 001 MSA-BJ-2B GE731E611 24' OA MIMSN-V812 1

MT 010 007 CNS-106-24 MIUP-WB12 1

UT 0 062 061 004 UT 45 045 044 001 MSA-BJ-3 GE731E611 24' E-P MIMSN-V812 1

MT 011 007 CNS-106-24 HIUP-V812 1

UT 0 062 061 004 UT 45 060 059 003 MSA-BJ-3A GE731E611 24' LS MIMSN-V812 1

MT 012 007 CNS-106-24 MIUP-W812 1

UT 0 062 061 004 UT 45 060 059 003

- - _ - _ _ _ _ _ _ _ _ _ _ = _ _ _ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - - _ _ _ _ _ - _ - - - _ _ _ _ _ _ _ _. - _ -

!$1 EAR CORP 0ME! IEEI COOPER IUCLut ST&f!]

SPRI D 1909 Page 16 of 32 Revision No.,,1_

((

ASME EIAN COMPONENT DRAVING/

SIZE CONF.

CNS CAL.

PROCEDURE REV.

EIAM EDSt CDS4 LDSI REMARKS CAT.

I.D. NUMBER ISOMETRIC STD. NO.

NUMBER TYPE p.

BJ MSA-BJ-4 CE731E611 24' P-P CNS-106-24 MIMSN-W812 1

HT 013 007 MIUP-V812 1

UT 0 062 061 004 UT 45 115 114 003 MSA-BJ-4A Gi.731E611 24' LS CNS-106-24 MIMSN-V812 1

MT 014 007 MIUP-V812 1

UT 0 374 373 004 UT 45 115 114 003 MSA-BJ-5 GE731E611 24' P-P CNS-106-24 FIMSN-VB12 1

MT 015 007 MIUP-V812 1

UT 0 062 061 004 UT 45 115 114 003 ESA-BJ-5A GE731E611 24' LS CNS-106-24 MINSN-VB12 1

MT 016 007 MIUP-V812 1

UT 0 062 061 004 UT 45 115 114 003 l

ISI HAM C0HP0ER IIDE

)

C00PR BUCLEAR STATI D SPRING 1989 Page 17 of 1 l

Revision No. 1 J (.

ASME EXAM COMPONENT DRAVING/

SIZE CONF.

PROCEDURE REV.

EXAM EDSt CALI REMARKS CAT.

I.D. NUMBER ISOMETRIC NUMBER TTPE B-K-1 PSA-BK1-23 2506-1 N/A N/A MIMSN-V812 1

MT 312A 307 FVA-BK1-28 2509-1 N/A N/A MIMSN-V812 1

MT 413 411'

]

i

)

TVA-K1-7 2509-1 N/A N/A MIEN-VB12 1

MT 386 385

]

f.

1' FVC-BK1-8 2509-2 N/A N/A MIEN-V812 1

MT 376 375 RHA-BK1-20 2510-3 N/A N/A MIEN-V812 1

MT 380 379 RHC-BK1-24 2510-3 N/A N/A MIMSN-V812 1

MT 387 385 MSA-BK1-18 GE731E611 N/A N/A MIEN-NB12 1

MT 322 321 EA-BK1-28 GE731E611 N/A N/A MIEN-V812 1

MT 366 362 MSA-BK1-6 GE731E611 N/A N/A MIMSN-V812 1

MT 158 157 MSB-BK1-32 GE731E611 N/A N/A MIMSN-V812 1

MT 365 362 EC-K1-12 GE731E611 N/A N/A MIEN-EB12 1

MT 367 362

. {.

EC-BK1-20 GE731E611 N/A N/A MIEN-V812 1

MT 369 362 MSD-K1-11 GE731E611 N/A N/A MIMSN-V812 1

MT 323 321 MSD-BK1-32 GE731E611 N/A N/A MIEN-V812 1

MT 368 362 1

"O >

ISI EIAR COMP 0EEE! IREI i

COOPERNUCLEARST&flO SPRIN 1989 Page _1B_ of 32 Revision No.,,1_

~

ASME EXAM C0KPONENT DRAWING SIZE CONF.

CNS CAL.

PROCEDURE REV.

EKAN EDSI CDSt LDSI REMARKS CAT.

I.D. E MBER FS. NO.

EMBER f!PE B-N-1 CORE SPRAY LINES N/A N/A N/A N/A VT-06 0

IVI V-001 N/A N/A DRTER N/A N/A N/A N/A VT-06 0

IVI V-001 N/A N/A

+

FEEDWATER N/A N/A N/A N/A VI-06 0

IV!

V-001 N/A N/A SPARGERS JET PUMPS N/A N/A N/A N/A VT-06 0

IVI V-001 N/A N/A PLATE BOLTS N/A N/A N/A N/A VT-06 0

IVI V-001 N/A N/A SEPARATOR N/A N/A N/A N/A VT-06 0

IVI V-001 N/A N/A SHROUD HEAD N/A N/A N/A N/A VT-06 0

IVI V-001 N/A N/A ASSEMBLY SURVEY SAMPLE N/A N/A N/A N/A VT-06 0

IVI V-001 N/A N/A

~

SURVEY SAMPLES N/A N/A N/A N/A VT-06 0

IVI V-001 N/A N/A TOP C'JIDE N/A N/A N/A N/A VT-06 0

IVI V-001 N/A F/A BELTLINE WELD N/A N/A N/A N/A VT-06 0

IVI V-001 N/a N/A AREAS em. '

m

_.____________m

_m

U ISI RAE C0 00E Bf 1 9 5 C00NR NBCIAAt STAf!0R SMI N 1989 Page 19. of 32 L

Revision No. I v.

n Q( '

t ASNE EXAH COMPONENT DRAVING/

SIZE C0hF.

CNS CA!..

PROCEDURE REV.

EIAM EDSI CDSB LDSt REMARKS CAT.

1.D.EUMBER ISOMETRIC STD. N0.

BUEER ffPE

'CA' RHE-CA-2A-

$UECO.M-82454 R/A VE-DR CNS-GE 16-75 BIUP-V812-1 UT-0 287 286 003

-CS UT-45 289 288 002 er i

\\

L t

t 1

..-(

i i

(a

,=

4 ISI IIAR CORPORER IEEE COOPER WCIRAR STITID SPRI N 1989 Page 20 of 32 Revision Ro. 1 ASE EIAE COMPOERT DRAVIE/

SIZE CORF.

PROCEDRE REV.

EIAE DS4 CA!,4 REMKS CAT.

1.D. RUMBER IS0HETRIC RUEER TYPE C<

CSB-CC-4 2603-2 R/A N/A HIER-V812 1

Ef 309 307 HPIS-CC-6 2611-6 R/A R/A BIER-V812 1

ET 308 307 RAS-CEl-1 2614-2 R/A R/A EIBSR-V812 1

Ef 279 255 Eva-CC-36 2621-1 R/A R/A IP-V812 1

PT 121 R/A HPID-CC-38 2623-2 R/A R/A HIBSR-V812 1

ET 329 327 RB-CEl-3 2624-1 R/A R/A E1555-V812 1

Ef 1%

194 RB-CEl-4 2624-1 R/A R/A EIER-V812 1

Ef 197 194 s

(12 til RPC-CC-24A 2624-1 R/A R/A HIER-V812 1

HT 312 307 RB-CC-44 2624-2 N/A R/A HIER-V811 1

ET 070 065 RB-CC-59 2624-2 N/A R/A HIER-V812 1

ET 312B 307 RAN-CEl-14 2624-3A R/A R/A EIER-V812 1

Ef 257 255

(

RAN-CEl-15 2624-3A R/A R/A EIER-9612 1

Ef 256 255 I

RBV-CEl-9 2624-3B R/A N/A IP-W812 1

P!

295 RCT-CEl-4 2624-3B R/A -

N/A IP-V812 1

PT 2%

EC-CC-36 2624-3B R/A R/A HIESR-V812 1

ET 304 303 HC-CEl-1 2624-3B R/A R/A IP-v812 1

PT 150 EC-CEl-3 2624-38 R/A R/A IP-V812 1

PT 150 RFB-CC-28 2624-3C R/A R/A HIER-V812 1

E!

225 284 PSA-CEl-7 2629-1 R/A R/A EIESN-V812 1

EI 401 399 RAV-CEl-1 2625-2 R/A R/A RIESR-V812 1

ET 402 399 HD-CEl-4 2624-6 R/A F./A IP-F812 1

PT 198 ED-CEl-5 2624-6 R/A R/l.

IP-V812 1

PT 150 RE-CC-3 2624-7 R/1 N/A EIER-V812 1

ET 305 302 1

h RAV-CEl-5 2625-1 R/A R/A BIER-V812 1

ET 066 065 BW-CEl-4 2625-2 R/A R/A HIER-V812 1

Ef 200 199 i

i

ISI EIAR CORPOR E ! IEDEI i*

C00PII 3DCl2At STATI ]

SPt! N 190f l

Page 2Lof 32 Redsira Ro. 1

(

ASME' I2AR COMPOREIT DRAVIRG/

fi!ZE CORF.

PROCEDURE EV.

IIAM dst CAI,6 RERARES l

Cif.

I.D. RUMBER IS0EftIC RUMBER TTPE 1

C-C EPD-CC-14 2625-2 V/A R/A IP-V812 1

PT 409 HPEX-CC 17 2614-3 R/A R/A E!EN-V812 1

NT 430 (29 EV-CEl-2 2625-4 R/A R/A HIBSI-V812 1

NT 306 303 EPB-CC-15 2625-4 R/A R/A 1P-V812 1

PT 409 CSB-CC-51 2602-1 R/A R/A E!EE-V812 1

- MT 400 399 l

1 RPB-CC-6 2626-2 R/A R/A HIER-V812 1

E 310 307 CSA-CC-73 2603-4 R/A R/A IP-V812 1

P'.'

4'M

~

PSA-CEl-1 2629-1 R/A R/A EIBSR-V812 1

HT 364 362 311 307 PSA-CEl-4 2629-1 R/A I/A HIBSR-V812 1

ET 981 080

+505-SECTIOR II CORPORERTe 276 255 RepairedPerVI 89-2658 RAS-CEl-4 2629 1 R/A I/A HI55R-V812 1

ET 328 327

('

RBS-CEl-3 1629-1 R/A I/A HIESI-V812 1

HT f/7 071 RHE-CC-26' C8&I-73 R/A R/A HIEl-V812 1

ET 378 375 EE-CC-27 CB&I-73 I/A li/A MIESFV012 1

tf 377 375 PNC-CEl-4 20D-755-2 I/A N/A EIFER-V812 1

HT 078 071 PRC-CEl-5 RCD-755-2 R/A N/A EIEFV812 1

HT 079 071 RSA <El-1 2601-4 R/A I/A 51ESEV812 1

ET 072 071 2HP E -51 262F2 R/A N/A HIESF-V812 1

ET 069 065

!$2 255 sw-S35-C[1-21 13 gS.10+-

N/A N/A I P-W812 1

PT 409 L

ISI EIAN Cour0EE E IEEI C M ER pgCLEIR STATI O SPRIN 1989 Page.22__ of 32 j

E Revision Ro. 1

(

ASRE EME C000REllt htAVIN/

SIZE Colff +

CBS CAL.

PROCDURE REV.

EIAE DS4 CDSB LDS8 inARR I

CAT.

I.D.RUMBER ISOMETRIC STD. 30.

ROMBER ffPE I

j C-f RSa-CF-18 2601-4 8'

P-E ELISR-9812 1

ET 067 065 RSA-CF-3 2614-1 8'

P-E IP-v812 1

PT 121 R/A R/A RAS-CF-4 2614-2 18' P-E HI}SR-V812 1

Ef 280 255 CNS-101-18-40-CS EIUP-v812 1

UT 0 265 264 002 UT 45 267 266 002 RAV-CF-78 2624-2 2(*

P-P

. HIER-V812 1

Ef 278 255 CKS-104-2(-30-CS, EIUP-9812 1

UT 0 269 26P 001 UT 45 271 270 001 A

SV-CF-5 2624-3A 14' P-V HIRSR-V812 1

ET 018 017 Bl{F-79 2624-3B 24' P-f MIESR-V812 1

Ef 239 238 CRS-104-24-30-CS HIUP-V812 1

UT 0 261 260 003 UT 45 263 262 003 RCT-CF-20 2624-3B 20' P-E E1555-5812 1

Ef 073 071 RHC-CF-2 2624-3B 16' P-E IP-VB12 1

PT 151 EV-CT-52 2624-5 6'

P-Y

- EIER-VB12 1

Ef 201 199 RED-CF-9 2624-6 6'

P-P IP-V812 1

PT 156 RAV-CF-25 2625-1 20' P-E HIER-V812 1

ET 068 065 RAV-CF-4 2625-2 20' P-E HIEE-E612 1

HT 331 327 BA-CF-2 2625-3 20' P-E Eli3R-VB12 1

ET 052 0486 DV-CF-18 2625-4 20' P-f EIEE-V812 1

ET 202 199 l

l DV-CF-6 2625-4 20' P-E HIMSR-VB12 1

Ef 123 122 R/A l

l EAV-CF-65 2626-3B 18' E-PC KIEE-8812 1

Ef 277 255 PSA-CF-12 2629-1 10' P-E EIEE-V812 1

ET 049 04BA 281 255 CRS-78-?0-100-CS HIUP-V812 1

UT C 160 159 001 UI 45 162 161 002 l

ISI RAM COEPO W ! IIDE C00PIRNOCIX.ARSTAflu

-j 4

y SPRI N 1999 l

('

Page 23 of 32 Revision No. 1 l

(;"'

i l<"

ASME EXAM COMPONENT DRAV!NG/

SIZE CONF.

CNSCAL.

PROCEDURE REV.

EIAM EDSI CDSt LDSI REMARKS CAT.

1.D. NUMBER ISOMETRIC STD. N0.

NUMBER

'rYPE C-F PSA-CF 3 2629-1 10' P-P MIEN-W812 1

MT 324 321 CRS-78-10-100-CS MIUP-VB12 1

Uf-0 335 334 333 i

l l

UT-45 337 336 003 PSA-CF-9 2629-1 10' P-E MIMSN-V812 1

MT 050 048A CNS-78-10-100-CS HIUP-V812 1

Uf-0 160 159 001 Uf-45 162 161 002 RAS-CF-12 2629-1 8'

P-E IP-V812 1

PT 295 CNS-73-8-100-CS HIUP-V812 1

UT-0 298 297 002 UT-45 300 299 002 RAS-CF-28 2629-1 8'

P-T M1MSN-V812 1

MT 051 04BA CNS-73-8-100-CS MIUP-VB12 1

UT-0 220 219 002 Uf-45 222 221 003 RBS-CF-13 2629-1 8'

P-E MIMSN-V812 1

MT 330 327 CNS-73-8-100-CS MIUP-V812 1

Uf-0 352 351 002 Uf-45 354 353 002 EllE-CF-19 CB&l-73 12' E-P HIMSN-V812 1

MT 164 163 CNS-83-12-120-CS MIUP-W812 1

Uf-0 185 184 001 UT-45 1B7 186 002 EliE-CF-10 CB&l-73 12' P-E MIMSN-V812 1

MT 363 362 CNS-83-12-120-CS MIUP-V812 1

Uf-0 356 355 002 UT-45 350 357 002 FNC-CG-3 RCO-755-1 24' E-R HIMSN-V812 1

MT 332 327 PNC-CG-11A RCO-755-1 20' P-PC MIEN-VB12 1

HT 074 071 N/A i

SC2G-20 F00-755-1 20' P-F HIMSN-V812 1

MT 076 071 N/A Rl!B-CF-2 2624-1 16' F-E MIMSN-V812 1

MT 195 194

(

RCT-CF-9 2624-3A 20' P-E MIMSN-VB12 1

MT 096 082 283 255 PNC-CG-5 MIEN-V812 1

MI 075 071

ISI BAE Coup 0ERT INDEI C

C00PER W CIB R STATID SPRI M 1989 Page 24 of 32 Revistor, No. 1 ASME HAM 3 DRAVING/

BLDG ELEV.

PROCEDURE REV.

EIAM EDS4 REMARKS CAT.

ID. NUMBER ISORETRIC 30.

NUMBER ffPE,

F-A RHS-50 2624-1 CONT.

943 IV3-V812 3

VT-3 234 IV4-V812 2

VT-4 N/A RHH-61 2624-3A CONT.

927 IV3-V812 3

VT-3 190 IV4-V812 2

VT-4 N/A RHH-44A 2624-3B CONT.

943 IV3-V812 3

VT-3 149 IV4-V812 2

VT-4 R/A RHH-46A 2624-3B CONT.

912 IV3-VB12 3

Vf-3 313 IV4-VB12 2

VT-4 R/A RHH-135 2624-6 CONT.

958 IV3-V812 3

VT-3 149 IV4-V812 2

VT-4 N/A MSH-101A 2629-1 CONT.

897 IV3-V812 3

VT-3 317 IV4-V812 2

VT-4 R/A RHS-63 2625-2 CONT.

183 IV3-V812 3

VT-3 415 IV4-V812 2

VT-4 R/A RHH-15 2626-2 CONT.

861 IV3-V612 3~

VT-3 124 IV4-V812 2

VT-4 R/A

. +

J

ISI RM C090ERT IEEI COOPER BBCLEAR STATI D SPRIN 1989 Page.25,_ of 32 Revision No. l_

l f.

ASNE HANGER DRAVING/

BLDG ELEV.

PROCEDURE REV.

EXAM EDSI REMARKS CAT.

ID. H MBER ISOETRIC NO.

NHBER f!PE i

F-B RM-56A 2624-3A CONT.

894 IV3-V812 3

VT-3 359 IV4-V812 2

VT-4

-N/A RH-56B

'2624-3A CONT.

894 IV3-V812 3

VT-3 317 IV4-li812 2

VT-4 N/A RM-52A 2624-3B CONT.

895 IV3-V812 3

VT-3 371 IV4-V812 2

VT-4 N/A RH-52B 2624-3E CONT.

895 IV3-V812 3

VT-3 371 IV4-V812 2

VT-4 N/A RM-64A 2624-5 CONT.

883 IV3-9812 3

Vf-3 203 IV4-V812 2

VT-4 N/A

'RM-9A 2625-1 CONT.

893 IV3-V812 3

VT-3 317 I

IV4-V812 2

VT-4 N/A RHS-74 2625-1 CONT.

867 IV3-V812 3

VT-3 234 IV3-V812 3

VT-4 382 RH-17A 2625-4 CONT.

873 IV3-V812 3

VT-3 124 IV4-V812 2

VT-4 N/A RHH-112 2626-3 CONT.

884 IV3-V812 3

VT-3 360 IV4-VB12 2

VT-4 N/A MSH-101 2629-1 C0KT.

894 IV3-VB12 3

VT-3 217 IV4-V812 2

VT-4 N/A l

PVH-108 RCO-755-2 CONT.

897 IV3-VB12 3

VT-3 315 IV4-V812 2

VT-4 N/A PVH-109 E00-755-2 CONT.

897 IV3-V812 3

VT-3 315 IV4-V812 2

VT-4 N/A C~

PVH-110 RCO-755-2 CONT.

897 IV3-VB12 3

VT-3 315 IV4-V812 2

VT-4 N/A i

?r a

1

t 181 HM C090ERT IEE C00 pit 38C158 sfATI']

SPRI N 1909 l

Page 26 of 1 a

nevision no. 1

(

ASRE RAEG DRAVIE/

BDG IIIV.

PROCEDURE REV.

EIAH D64 RERARIS CAT.

ID. W EBER IS0BEftIC E.

BUSEE f!PE F-B PVS-lut 900-755-2 CORT.

897 If3-V812 3

?!-3 371 If4-9812 2

?!-4 R/A PVS-2MR RC0-755-2 C0ET.

897 If3-V812 3

?!-3 315 If4-V812 2

ff-4 IIA RB-S61 2625-2 C0t!.

If3-V812 3

ff-3 203 s.

IT4-VB12 2

ff-4 R/A BSS-70 2601-4 COE!.

877 IT3-V812 3

ff-3 360 IV4-VC12 2

?!-4 R/A HP-H9 26116 COET.

861 173-V612 3

ff-3 397 If4-V812 2

ff-4 R/A RHH-19 2626-2 COR.

861 If3-V812 3

ff-3 397 If4-V812 2

?!-4 X/A RfH-68 2509-1 M

921 IT3-VB12 3

ff-3 272 427 IV4-V812 2

fr-4 R/A CSS-17 2603-4 COM.

897 IV3-V812 3

ff-3 415 IV4-V812 2

TI-4 R/A RCH-5 2621-1 Coff.

860 IV3-V812 3

TI-3 124 IV4-V812 2

ff-4 R/A PSA-1 EP-1A-2-1-1-2 COM.

906 IV3-VB12 3

ff-3 403 IV4-VB12 2

ff-4 R/A

~

1 3,

ISI HAM C000E Bf INDEX C00PR NCLEAR STATIC SPRING 1989 Page 27 of 32 -

RevisionNo._L l(-

ASME HANGER DRAVING/

BLDG ELEV.

PROCEDURE REV.

EIAM EDSt REMARKS CAT.

ID. BU SER ISOMETRIC 90.

EMBER TIPE l'-C EH-134A 2506-1 CONT.

906 IV3-V812 3

VT-3 427 IV4-V812 2

VT-4 428 BSH-109 2601-4 CONT.

877 IV3-V812 3

VT-3 371 IV4-W812 2

VT-4 372 MSH-120 2614-1 CONT.

873 IV3-V812 3

Vf-3 149 IV4-V812 2

VT-4 449 MSH-123 2614-1 CONT.

877 IV3-V812 3

VT-3 149 IV4-V812 2

VT-4 449 MSH-141 2614-2 CONT.

946 IV3-V812 3

Vf-3 234 IV4-V812 2

VT-4 235 RM-30 2624-1 CONT.

951 IV3-V812 3

VT-3 234 IV4-WB12 2

Vf-4 235 RM-94 2624-2 CONT.

925 IV3-V812 3

VT-3 190 IV4-VB12 2

VT-4 191 RM-56 2624-3A CONT.

892 IV3-V812 3

VT-3 317 IV4-W812 2

VT-4 316 RE-60 2624-3A CONT.

919 IV3-V812 3

VT-3 190 IV4-V812 2

VT-4 191 HS-56 2624-3A CONT.

927 IV3-V812 3

VT-3 190 IV4-V812 2

VT-4 191 RS-57 2624-3A CONT.

927 IV3-V812 3

VT-3 190 IV4-V812 2

VT-4 191 RE-59 2624-3A CONT.

892 IV3-WB12 3

VT-3 317

~

IV4-W812 2

VT-4 316 RM-50 2624-38 CONT.

909 IV3-V812 3

VT-3 313 IV4-W812 2

VT-4 314 i

4 -

ISI EI M COMPOR ET I E EK COOP E NUCLEAR STATI!J SPRIN 1989 Patp 28 of.32,

Revision No. _L

(~

ASME HANGER DRAVIM/

BLDG ELEV.

PROCEDURE REV.

EIAM EDSI REE KS CAT.

ID. NUMBER ISOMETRIC N0.

NUMBER T!PE F-C-RHS-40 2624-3B CONT.

915 IV3-WB12 3

VT-3 313 IV4-W812 2

VT-4 314 RH-134 2624-6 CONT.

959 IV3-V812 3

VT-3 149 IV4-VB12 2

VT-4 449 RH-10 2625-1 CONT.

890 IV3-VB12 3

VT-3 317 IV4-V812 2

VT-4 316 HH-20 2625-1 CONT.

897 IV3-U812 3

VT-3 360 IV4-V812 2

VT-4 361 RM-62 2625-1 CONT.

898 IV3-U812 3

VT-3 371 IV4-W812 2

VT-4 372 RHS-76 2625-1 CONT.

894 IV3-V812 3

VT-3 317 IV4-V812 2

VT-4 316 RHS-78 2625-1 CONT.

894 IV3-UB12 3

VT-3 317 IV4-V812 2

VT-4 316 RH-12 2625-4 CONT.

884 IV3-V812 3

VT-3 203 IV4-V812 2

VT-4 204 RM-17 2625-4 CONT.

861 IV3-V812 3

VT-3 124 IV4-W812 2

VT-4 449 RHS-65 2625-4 CONT.

889 IV3-W812 3

VT-3 R/L-203

  • TWO DIFFERENT S WBBERS IV4-V812 2

VT-4 R/L-204

  • TWO DIFFERENT SNUBBERS RHS-44 2626-4 CONT.

883 IV3-V812 3

VT-3 U/D-203

VT-4 U/D-204

  • TWO DIFFERENT SSUBBERS RH-86A 2626-4 CONT.

883 IV3-V812 3

VT-3 203 MSS-16 2629-1 CONT.

879 IV3-V812 3

VT-3 317 MODIFIED AND

-(

432 REEKAMINED 1

IV4-V812 2

VT-4 316 MODIFIED HD 433 EEEXAMINED

l.

-ISI ZIAH COEP0 E R INDE t*

C00PR ROC 2AR STATI"!

8 PRIM 1*;9 l

Page 29 of 32 l

RevisionNo.,J__

ASME RAMER DRAVIM/

BLDG ELEV.

PROCEDURE REV.

EXAM EDSt REMARS CAT.

ID. NUMBER ISOMETRIC N0.

NUMBR f!PE l

F-C -

MSS-75 2629-1 CONT.

932 IV3-VB12 3

VT-3 415 IV4-V812 2

VT-4 416 MSS-76 2629-1 CONT.

932 IV3-V812 3

VT-3 403 IV4-V812 2

VT-4 404 MSH-102 2629-1 CONT.

923 IV3-VB12 3

VT-3 313 IV4-V812 2

VT-4 314 MSH-109 2629-1 CORT.

906 IV3-V812 3

VT-3 427 IV4-V812 2

VT-4 428 MSH-114 2629-1 CONT.

894 IV3-V812 3

VT-3 317 IV4-V812 2

VT-4 316 RHEH-1 CMI-73 CORT.

IV3-V812 3

VT-3 392 IV4-VB12 2

VT-4 R/A RHEH-2 CMI-73 CORT.

IV3-V812 3

VT-3 392 IV4-V812 2

VT-4 N/A HA-1 GE731E611 DV BB4 IV3-V812 3

VT-3 427 IV4-V812 2

Vf-4 428 PVH-104 RCO-755-1 CONT.

895 IV3-VB12 3

VT-3 315 IV4-V812 2

VT-4 E/A PVH-104A RCO-755-1 CONT.

IV3-VB12 3

VT-3 315 IV4-V812 2

VT-4 R/A PVH-104B 200-755-1 CONT.

IV3-VB12 3

Vf-3 315 IV4-V812 2

VT-4 R/A PVH-106 R00-755-1-2 CONT.

897 IV3-VB12 3

VT-3 315

~

IV4-VB12 2

VT-4 449 k'

PVS-11 R00-755-2 CONT.

173-5812 3

VT-3 315 IV4-V812 2

VT-4 E/A ll

.m_

ISI BAE C090ERf IDEI 3=

COOPERBUCLERSTATID SPRING 1909 Page 30 of 32

[;

[

Revision No. 1 L(l ASBE RANGER DRAVING/

BIAG ELEV.

PROCEDURE REV.

EIAM EDS4 REMAR[S CAT.

'ID. BUMBER ISOMETRIC 50.

N'JHBER ffPE F-C RHH-47 2624-3B CON!.

905 IV3-V812 3

VT-3 313 IV4-V812 2

VT-4 314 RH-140 2624-7 CONT.

906 IV3-VB12 3

VT-3 313 IV4-V812 2

VT-4 449 RHH-14 2625-2 COET.

861 IV3-VB12 3

VT-3 313 i

IV4-VB12 2

VT-4 314 MSS-10 2629-1 COET.

894 IV3-V812 3

VT-3 317 E

IV4-V812 2

VT-4 316 MSH-106 2629-1 CORT.

817 IV3-VB12 3

VT-3 371 IV4-VB12 2

VT-4 372 RSH-97 2629-1 Coff.

885 IV3-VB12 3

97-3 371 IV4-V812 2

VT-4 372 RHH-89 2624-2 COEf.

898 IV3-V812 3

VT-3 371 IV4-V812 2

VT-4 372 RHS-22 2624-2 CONT.

895 IV3-V812 3

VT-3 371 IV4-V812 2

V!-4 372 HA 2 GU31L611 M

IV3-V812 3

VT-3 388 IV4-V812 2

VT-4 389 E-3 GE731E611 N

IV3-VB12 3

VT-3 388 IV4-VB12 2

VT-4 389 HB-3 GE731E611 N

IV3-V812 3

VT-3 388 IVFV812 2

VT-4 389 SSB-3 GE731E671 N

IV3-V812 3

VT-3 3BB 923 IV4-V812 2

VT-4 389 r

(-

'RM-136 St5163 CORT.

926 IV3-VB12 3

VT-3 390 IV4-V812 2

VT-4 391 j

y; I6I Eng C0 00EEE IIDEX.

C00pIR BOCLRAR STATI~J SPRIM 1989 Page 31 of 32 Revision No. 1 ASE RANGER DRAVIE/

BLDG ELEV.

PROCEDURE REV.

EIAR EDSI REMARKS

.CAf.

ID. NUMBER IS0ETRIC NO.

NUMBER ffPE F-C CS-H1 2603-2 COM.

861 IV3-V812 3

VT-3 397 IV4-U812 2

Vf-4 398 RFS-13 2509-2 DV 929 IV3-U812 3

Vf-3 272 IV4-V812 2

VT-4 273 RHH-34 2510-1 DV 923 IV3-V812 3

TI 3 272 IV4-VB12 2

VT-4 273 RHH-70 2510-3 DV 912 IV3-VB12 3

VT-3 272 IV4-V812 2

Vf-4 273 RFS-17 2509-1 DV 928 IV3-VB12 3

VT-3 403 IV4-V812 2

VT-4 404 RSH-155L 2614-3 CORT.

880 IV3-V812 3

VT-3 415 IV4-U812' 2

Vf-4 R/A RHS-55 2624-1 CORT.

873 IV3-V812 3

VT-3 (19 IV4-V812 2

VT-4 (20 RHS-21 2624-2 CORT.

906 IV3-V812 3

VT-3 403 IV4-V812 2

VT-4 404 ERS42 2624-3C CONT.

878 IV3-V812 3

VT-3 415 IV4-V812 2

VT-4 416 MSH-112 2629-1 CONT.

674 IV34812 3

VT-3 415 IV4-VB12 2

VT-4 416 BC-3 GE731E611 DV IV3-V812 3

VT-3 427 IV4-V812 2

VT-4 428 e

HD-3 GE731E611 DV IV3-V812 3

VT-3 427 1

IV4-VB12 2

VT-4 428

ISI BAE C09 0 E Rf IEDEI 1, -

o-COOPER HUCLEAR ST&f1 D SPRIN 1989 q

Page 32 of 32' Revision No. 1 I

(!

ASE HARGER DRAVING/

BLDG ELEV.

PROCEDURE REV.

EEAM EDS4 RERARKS CAT.

ID. BUMBER IS3ETRIC B0.

NUSER ff?E F-C SSC-3 GE731E611 DV 923 IV3-V812 3

Vf-3 427 IV4-VB12 2

VT-4 428 SSD-3 GE731E611 DE 923 IV3-V812 3

Vf-3 427 IV4-VIil2

-2 VT-4 428 EH-115 2623-1 COM.

IV3-V812 3

VT-3 440 IV4-V812 2

VT-4 441 L

RH-42 2624-3B CORT.

933 IV3-W812 3

Vf-3 149 IV4-V812 2

VT-4 449 CS-B10 2602-1 CONT.

920 IV3-VB12 3

VT-3 425 IV4-VB12 2

VT-4 426 ES-9A 2629-1 CONT.

894 7.2.34.2 R/A Vf 3/4 460 ES-9B 2629-1 CONT.

894 7.2.34.1 N/A Vf-3/4 461 ES-21 2506-1 DI 919 7.2.34.2 K/A Vf-3/4 462 ES-22 2506-1 DV 919 7.2.34.1 N/A VT-3/4 463 d

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska Public Power District Date August 30, 1989

~

(Name).

P.O. Box 49, Columbus, NE 68601 Sheet 1

of 39 (Address)

2. Plant Cooper Nuclear Station.

Unit

- One (Name)

P.O. Box 98, Brovnville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Main Steam (MS)

~

5. (a) Applicable Construction Code USAS B31.7 19 69
Edition,

-No

Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 ) uwter ITSlAAAmdn.
6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

MS'-A0V-A086A Rockwell 1

89-0660- - Replacement No MS-A0V-A086B Rockwell 1

89-1675 Replacement No.

MS-A0V-A086C Rockwell 1

89-1675 Replacement No MS-A0V-A086D Rockwell 1

89-1675 Replacement No MS-A0V-A086A Rockwell 1

89-0574 Replacement No

7. Description of Work: Replace valve stem, stem disc, main disc, piston, and junk ring.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X

Other Pressure 1000 psi Test Temp.

$200 *F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided -(1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l

'9.

Remarks This NIS-2 Report provides the required information on repairs and'repl'acements performed at Cooper Nuclear St'ation from January, 1989

_through June, 1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked'through

_the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to_be Attached; CERTIFICATE OF COMPLIANCE We certify that the. statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorizat' ion No.

N/A Expiration Date N/A Signed C

- f.& *w.n.

Date 6 6Ci (Owr.er or Owner's Designee, Title)

CERTIFI' ATE OF INSERVICE INSPECTION C

-I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nehrnnkn and employed by Hnrtford 9tonm En11 er T&T Co.

of.

unrtfnra rT have inspected the components described in this Owner's Report during the period annnnvy iggg-to Jun e 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

-By signing-this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature

)h) h_ s (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State. Province, and Endorsements)

()-fh-h)}

Date

(_

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska Public Power District Date August 30, 1989 (Name)

P.O. Box 49 Columbus, NE 68601 Sheet 2

of.

39 l

(Address) l

2. Plant Cooper Nuclear Station Unit One

~

(Name)

P.O. Box 98, Brownville, NE 68321 N/A l

(Adcress)

(Repair Organization, P.O. No.

l Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Main Steam (MS)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or y nnter 19 81 A d de~d a.

Replacements 19 80 w

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Ccde Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

MS-A0V-A080A Rockwell 1

89-0608 Replacement No MS-A0V-A080B Rockwell 1

89-1675 Replacement No MS-A0V-A080C Rockwell 1

89-1675 Replacement No MS-A0V-A080D Rockwell 1

89-1675 Replacement No l

1 i

7. Description of Work:

Replace valve stem, stem disc, main disc, piston, and junk ring.

8. Tests Conducted: Hydrostatic

_ Pneumatic j

Nominal Operating Pressure X

j Other Pressure 1000 psi Test Temp.

s200 *F NOTE:

Supplemental sheats in form of lists, sketches, or drawings may be used, provided (1) size is 8S" x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this form.

l

9. Remarks This NIS-2 Report provides the required information on repairs and replacements' performed at Cooper Nuclear Station from January, 1989-through June, 1989. Also' Code Case N-308, " Documentation of Repairs'and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made 1n the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A ru. m a. Date 9fD Ul Signed frM ham _

(Owner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National board, State. Province, and Endorsements)

Date Q~ @~ &

1 l

a

O-FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As_ Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska'Public Power District Date August 30, 1989 (Name)

P.O. Box 49. Columbus, NE 68601 Sheet 3

of 39 (Address)

2. Plant Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A-(Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Nuclear Boiler (NB)
5. (a) Applicable Construction Code ASME Section III 19 77
Edition, Winter 78
Addenda, N/A Code Case (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 19 80 y wrob [q gi /tModg.
6. Identification of Components Repaired or Replaced and Replacement Ccaipunents W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RPV Top Head West Jersey Nozzle N6A Mfg.

1 89-0633 Replacement No Blind Flange RPV Top Head West Jersey Nozzle N6B Mfg.

I 89-2595 Replacement No Blind Flange

7. Description of Work: Replace blind flange with new blind flange.
8. Tests Conducted: Hydrostatic l'neumatic Nominal Operating Pressure X

Other Pressure 1000 psi Test Temp.

s200 *F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 l

through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

1

N

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989 throagh June, 1989. Also Code Case N-308. " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date F/A Signed h11 c-

-fd,. e.

Date D M (Owner or Owner's Designee. Title)

CERTIFICATE OF INSERVICE' INSPECTION I,:the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature

01. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State Province, and Endorsements) h-h - N Date l

l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska ~Public Power District Date,

August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 4

of 39 (Address)

2. Plant Cooper Nuclear Station Unit. One (Name)

P~.O. Box 98, Brownville, NE 68321 N/A

~

(Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Reactor Water Cleanup (RWCU)
5. (a) Applicable Construction Code ASME Section III 19 68
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 W;.M 14 %) /htel d.

y l

6. Identification of Components Repaired or Replaced and Replacement Components l'

W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

Ingersoll RWCU-P-B Rand 2

89-1145 Replacement No

-Ingersoll RWCU-P-A Rand 2

89-1742 Replacement No

7. Description of Work: Replace pump with new pump.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X

Other Pressure psi Test Temp.

  • F NOTE:

Supplemental sheets in form of lists, sketchen, or drawings may be used, provided- (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also' Code Case N-308, " Documentation of Repa' irs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

~~

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement) 1 Type Code Symbol Stamp

-N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed (d

Es va.

Date 9lSl tfi (Owner or Owner's Designee, Title) 1 CERTIFICATE OF INSERVICE INSPECTION I, the under:1gned, holding e. valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by "srtford Steam Boiler I&I Co.

l of Hartford, CT have inspected the components

)

described in this Owner's Report during the period January 1989 l

to June 1989

, and state that to the best of my knowledge and belief, the-Owner has performed examinations and taken corrective measures i

described in this Owner's Report in accordance with the requirements of l

the-ASME Code Section XI.

l

-By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and i

-corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements)

Date _

Q~h-f

]

q FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

)

1. Owner Nebraska Public Power Distrlet Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 5

of 39 j

(Address)

I

2. Plant'

. Cooper Nuclear Station Unit One (Name)

P.O.' Box 98, Brownville, NE 68321 N/A

~

(Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Main Steam (MS)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 w; der itEl Ahfed.

y

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear cument Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

MS-A0V-A086A Rockwell 1

89-1635 Repaired No

)

7. Description of ifork: Lap main disc, main disc seat, stem disc, and stem disc seat.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X

Other Pressure 1000 psi Test Temp. 4200 'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l

9. Remarks This NIS-2 Report provides the required information on r pairs j

and replacements performed at Cooper Nuclear Station from January, 1989 through-June, 1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through l

the use of Form NIS-2 for reporting.

l Applicable Manufacturer's Data Reports to be Attached l

l-CERTIFICATE OF COMPLIANCE 1'

o We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A l

Certificate of Authorization No.

N/A Expiration Date N/A Df6C

(/M N Signed tm. W,L Date l

(Owner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION

-I, the undersigned, holding a valid commission issued by the National-Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components l

described in this Owner's Report during the period-January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code Section XI.

l By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore.

-neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements)

Date h-h-N L-_-_--

I '

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

[

1. Owner Nebraska Public Power Dis'trict Date August 30, 1989'

^

(Name)

P.O. Box 49, Columbus, NE 68601 Sheet 6

of 39 (Address)-

2. Plant Cooper Nuclear Station Unit One (Name)

P.O.' Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Residual Heat Removal (RHR)
5. (a) Applicable Construction Code Contract E69-4 19 N/A Edition, N/A
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80, v der M11 A&/a.
6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

Dragon Valve RHR-V-147 Company 2

88-4099 Replacement No

7. Description of Work: Replace va,1ve with new valve.
8. Tests Conducted: Hydrostatic X

Pneumatic Nominal Operating Pressure Other Pressure 564 psi Test Temp. Ambient *F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I t

9. Renarks This NIS-2 Report provides the required information o"__;epairs l

and replacements performed at Cooper Nuclear Station from January, 1989 I

through June, 1989. Also Code Case H-308, " Documentation of Repairs and l

1 Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached

{

l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

i (repair or replacement)

]

)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A j

F

- fX6 m(A -

i> ate 4 6 69 Signed (Owner or Owner's Designee. Title)

I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

)

of Hartford, CT have inspected the components i

described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and teken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising 1 rom or connected with this inpsection.

Inspector's Signature

[Nbk (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements) i Date Q-h-b

J l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner ~ Nebraska Public Pow'er District Da'te

' August' 30, 1989 (Name).

P.O. Box 49, Columbus, NE 68601 Sheet 7

of 39 (Address) 2.-Plant Cooper Nuclear Station Unit ' One (Name)

~

P.O. Box 98, Brownville, NE.68321 N/Ar (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Residual Heat Removal (RHR)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or-Replacements 19 80

,Wk b 1491Addmde.

6. Identification of Components Repaired or Replaced and Replacement Components rk Fepaired ASHE Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RAW-CF-65 N/A 2

89-1486 Rep' aired No I

7. Description of Work: Flap weld. RAW-CF-65 for surface examination.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I i

[

9. Remarks This NIS-2 Report provides the required information on repairs

~ and replacements' performed at Cooper Nuclear Station from January, 1989 l

Also Code Case-N-308, " Documentation of Repairs and l

f

.through June, 1989.

l Replacements of Components in Nuclear Power Plants".is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached I

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms'to the rules of the ASME Code Section XI.

L (repair or replacement) j Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A i

I Signed b~

fq.. mit. Date 0l l

(Ownsi or Owner's Designee, Title) l 4

' CERTIFICATE OF INSERVICE INSPECTION 4

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesdel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

)

of Hartford, CT have inspected the components I

described in this-Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has-performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, I

neither the Inspector nor his employer shall be liable in any manner for j

any personal injury or property damage or a loss of cny kind arising from 1

or connected with this inpsection.

)

Inspector's Signature W. B. Erb)

Commissions NB 8033 Nebr. 8033 l

(National Board, State, Province, and Endorsements)

Date 9hM 1

lu-_____-_--__-_--

i s

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS i

As Required by the Provisions of the ASME Code Section XI i

1. Owner Nebraska Public Power District

-Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 8

of 39

-(Address)

2. Planc Cooper Nuclear Station Unit One (Name)

P.O.-Box 98, Brownville, NE. 68321 N/A I

(Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Residual Heat Removal (RHR)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 y wkb I491 AJdf*J A.
6. Identiff. cation of Components Repaired or Replaced and Replacement Components "E"

^

Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RHR-RO-251 N/A 2

89-2020 Replacement No

7. Description of Work: Replace restricting orifice with new restricting orifice.

l

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X

Other Pressure psi Test Temp.

  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

E _ _ __ _

9. Remarks This NIS-2 Report provides the required information on repairs I

and replac'ements' performed at Cooper Nuclear Station frcm January, 1989 through June 1989. Also' Code Case N-308, " Documentation of Repairs'and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

I Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE i

We. certify that the statements made in the report are correct and this

]

(repair or replacement)

I j

replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A l

Certificate of Authorization No.

N/A Expiration Date N/A I

Signed ff')h W M n% L Date 4 b 68 (Owner or Owner's Designee Title)

CERTIFICATE OF INSERVICE' INSPECTION I, the undersigned, holding a' valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components i

l described in this Owner's Report during the period January 1989 to _ June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of 1

-the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore,

-neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature l

(H. B. Erb) h

' Commissions NB 8033 Nebr. 8033 (National Board, State. Province, and Endorsements) l Date h-k -h

i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS j

As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska Public Power District Date August' 30, 1989 (Name)

P.O. Box 49 Columbus, NE 68601 Sheet 9

of 39 j

(Address)

[

l

2. Plant Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Residual Heat Removal (RHR)
5. (a) Applicable Construction Code USAS B16.5 19 68
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 Wiwitr 1451 Actdew/a.

y

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

Anchor Valve RHR-MOV-M027A Company 1

89-1643 Repaired No

7. Description of Work: Grind / flapped valve body areas (inside) and lapped valve seat and disc.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X

Other Pressure psi Test Temp.

'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs

~

and replacements performed at Cooper Nuclear Station from January, 1989 l

through June, 1989. Also Code Case N-308, " Documentation of Repairs'and l

l b

Replacements of Components in Nuclear Power Plants", is invoked through i

the use of Form NIS-2 for reporting.

j Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code,Section XI.

l' (repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed C

MDW Date 9D 69 (Owne'r or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&1 Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief,-the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature l

(H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements) h-h-h Date

y____,--

~

4.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Neisa'ka Public Power District

'Date August 30, 1989 1.50wner s

(Name)

P.O. Box 49, Columbus, NE 68601 Sheet 10 of.

39 (Address) 1 J

2. Plant Cooper Nuclear Station Unit One (Name)

P.O.' Box 98,.Brownville, NE 68321 N/A (Address)

(Repair. Organization, P.O. No.

Job No. Etc.)

3. Work Performed By' Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Main Steam (MS)

~

5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b)-Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 wadc< l(t) Mala.

y

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear cument Replace,t, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

MS-H134A N/A 1

89-2657 Repaired No

7. Description of Work: Ground out indication in plate weld and rewelded.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs and repideements performed at Cooper Nuclear Station from January, 1989 through June. 1989. Also Code Case N-308, " Documentation of Repairs'and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We. certify that the statements made in the report are correct and this repair-conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed

[4 n A Mto.Date' 9Fl (Ow~ner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the' undersigned, holding a valid commission issued by the-National Board of Boiler.and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes-any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature

[

t (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State. Province, and Endorsements) h h-h Date

FORM NIS-2 OWNER'S REPORT.FOR REPAIRS OR REPLACEMENTS As Required by.the' Provisions of the ASME Code Section XI

1. Owner Nebraska Public Power District Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 11 of 39 (Address)

2. Plant Cooper Nuclear ~ Station Unit One (Name)

P.O. Box 98,'Brownville,'NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Main Steam (MS)
5. (a)~ Applicable Construction Code

'USAS B31.7 19 69

Edition, No
Addenda, N/A Code Case (b) Applicable. Edition of Section XI Utilized for Repairs or Replacements 19 80 y umtv 14%) A & /a.
6. Identification of Compcaents Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number - Replacement (Yes or No)

MS-H97 N/A 1

89-2658 Repaired No

7. Description of Work: Repaired tack weld on pipe support sadd10.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be I

used, provided (1) size is 8 " x 11", (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs l

and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-298, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed F/

4 NGL Date O 6Cl (Owner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

Ey signing this certificate neither the Inspector nor his employer makes any warranty, expressed or imp 31ed, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature f

f-q U. B. trb) 1 Commissions NB 6033 Nebr. 8033 (National Board, State Province, and Endorsements)

Date h-h-h)

?.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI A' gust 30,"1989

1. Owner _ Nebraska Public Power District Date

~

~

u (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 12 of 39 (Address)

2. Plant Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, Ni 68321 N/A

(Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration'Date N/A

4. Identification of System Main Steam (MS)
5. (a) Applicable ' Construction Code _

USAS B31.7 19 69

Edition, No
Addenda, N/A

,_ Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 ) Vi &r 1471 Auedot.

6. Identification of Components Repaired or Replaced and Replacement Components "P*'#*

^"

Name of Name of Nuclear Document Eeplaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

MS-A0V-A086C Rockwell 1

89-2694 Replacement No i

4

7. Description of Work: Replaced three sets of threads on valve body used for limit switch support.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided- (1) size is 8 " x 11", (2) information in items '

through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

]

9. Remarks This NIS-2 Report provides the required information on repairs

'and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs'and Replacements of Components in Nuclear Power Plants", is invoked through i

the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed b& MM - Date O 69 (Osner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION

- I the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures i

described in this Owner's Report in accordance with the requirements of l

the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Dwner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

1 Inspector's Signature f

(H. B. Erb)

Commissions NB 8033 Nebr. 8033 i

(National Board State Province, and Endorsements)

Date h,h-h)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska Public Power District Date August 30, 1989 (Name).

P.O. Box 49, Columbus, NE 68601 Sheet 13 of 39 (Address)

2. Plant

' Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Dwner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System

, Reactor Water Cleanup (RWCU)

5. (a) Applicable Construction Code ASME Section III 19 74 Edition.

Winter 75

Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 woier ii$l Addas/a.

y

o. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear cument Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

Anchor RWCU-CV-15CV Darling 1

89-2091 Replacement No

7. Description of Work: Replaced pressure seal and hinge pin gaskets.

l l

8. Tests Conducted: Hydrostatic Pneumatic l

Nominal Operating Pressure X

Other Pressure psi Test Temp,

  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

L_____-_____.

l

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989 l

through June, 1989. Also Code Case N-308, " Documentation of Repairs and 1

Replacements of Components in Nuclear Power Plants", is invoked through l

l the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF CCMPLIANCE We certify that the. statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

- Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed

.%_f_gG. vwt. Date 6 MI (Obner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid-commission issued by the National i

Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT _

have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, l

neither the Inspector nor his employer shall be liable in any manner for i

any personal injury or property damage or a loss of any kind arising from I

or connected with this inpsection.

Inspector's Signature h

(H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements)

Date 9 - h-@

l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI l

1. Owner Nebraska Public Power District Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 14 of 39 (Address)

2. Plant Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Standby Liquid Control (SLC)
5. (a) Applicable Construction Code ASME Section III 19 77
Edition, Summer 1977
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 Wiwk 14%l AModa.

7

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

SLC-SQBV-14A Conax Corp.

I 89-2313 Replacement No SLC-SQBV-14B Conax Corp.

I 89-2313 Replacement No

7. Description of Work:

Replaced valves with new valves.

8. Tests Cop /,cted: Hydrostatic Pneumatic Nominal Operating Pressure X

Other Pressure psi Test Temp.

'F NOTE:

Supplemental sheets in form of lists; sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

4

j

~9. Remarks This NIS-2 Report provides the required information on repairs

~ and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case-N-308. " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through

]

the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached 1

CERTIFICATE OF COMPLIANCE We certify that the statemcats made in the report are correct and this

-replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp _

Jg _,_

Certificate of Authorization No.

n/A Expiration Date N/A 3

(T9 Signed t

(fM. v%L Date (Owner or Owner's Designee Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the. State or Province of Nebraska-and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,-Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be-liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements)

Date 9-h-hf

l i.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI l

1. Owner Nebraska Public Power District Date August 30, 1989 l-(

.. Name)

P.O. Box 49. Columbus, NE 68601 Sheet 15 of 39 (Address)

2. Plant Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Residual Heat Removal (RHR)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 wider IT9f AMMA.

y

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document - Replaced, or Stamped Component Manufacturer Class Number Replacement.

(Yes or No) kH-S54 N/A 2

89-1548 Replacement No RH-H28 N/A 2

89-1548 Replacement No RH-H27A N/A 2

89-1548 Replacement No RH-H27 N/A 2

89-1548 Replacement No RH-H45 N/A 2

89-1548 Replacement No

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l L,

l

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January,1989

.through June, 1989. Also Code Case-N-308, " Documentation of Repairsiand Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports.to be Attached CERTIFICATE OF COMPLIANCE We certify.that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement) l Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed

/7 Et% N% A Date 9

(Owner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

= Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature

[h(3d[,ff-(H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements)

Date h '- h - b l

FORM EIS-2 OWMER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section X1

1. Owner Nebraska Public Power District Date August 30, 1989 (Name) l P.O. Box 49 Columbus, NE.68601 Sheet 16 of 39 (Address)
2. Plant Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A-(Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

-4.

Identification of System Residual Heat Removal (RHR)

5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 Winice f6l A//mdA.

j

6. Identification of Components Repaired or Replaced and Replacement Components rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RHR-H132 N/A 2

89-1548 Replacement No RH-H89 N/A 2

89-1548 Replacement No RH-H63 N/A 2

89-1548 Replacement No RH-H90 N/A 2

89-1548 Replacement No RH-H56B N/A 2

89-1968 Replacement No

7. Description of Work: Modify support to reduce member stress.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs and

~

Replacements of Components in Nuclear Power Plants", is invoked through the use'of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed CV

%%.*WO Date 69 (Ownsr or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION 1

I, the undersigned, holding a valid commission issued by the National j

Board of Boiler and Pressure Vessel Inspectors and the State or Province j

of Nebraska and employed by Hartford Steam Boiler I&I Co.

j of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of j

the ASME Code,Section XI.

l By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, I

neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from I

or connected with this inpsection.

Inspector's Signature (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, ar.d Endorsements)

Date Cg ~ 8 - M

FORM HIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS i

As Required by the Provisions of the ASME Code Section XI l

1. Owner Nebraska Public Power District Date August 30, 1989 (Name) l P.O. Box 49, Columbus, NE 68601 Sheet 17 of 39 (Address)
2. Plant Cooper Nuclear Staticn Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Main Steam (MS)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 w;#ee (UI A//M A.

y

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

MS-H117 N/A 2

89-1548 Replacement No MS-H107 N/A 2

89-1548 Replacement No MS-H157 N/A 2

89-1548 Replacement No MS-H96 N/A 2

89-1548 Replacement No N/A 2

89-1968 Replacement No MS-H126 1

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this ferm.

0'

9. Remarks This NIS-2 Report provides the required information on rept. irs

~

and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed

(~)

r % mut Date 63 (Owner or Owner's Designee Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT

___ have inspected the components described in this Owner's Report during-the period-January 1989 to June 1989

, and state that to the best of my knowledge and

-belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, l

neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature

[

(H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements)

Date k-h-h

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

~

1. Owner Nebraska Public Power District Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE.68601 Sheet 18 of 39 (Address) 2.' Plant Cooper Nuclear Station-Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A

. Address)

(Repair Organization, P.O. No.

(

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Core Spray (CS)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 Wuter t4gt Akbh.

y

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

CS-H21 N/A 2

89-1548 Replacement No CS-E26 N/A 2

89-1548 Replacement No CS-VE2 N/A 2

89-1958 Replacement No CS-H19A N/A 2

89-1968 Replacement No

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided-(1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

e

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, Documentation of/ Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A' Certificate of Authorization No.

N/A Expiration Date N/A Signed r-O h = -

% W -A.-

Date 8fl (0wher or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebra ska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief,-the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, i

neither the Inspector nor his employer shall be liable in any manner for l

any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature kJ r

j (H. B. Erb) j Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements) k-h- h Date

FORM NIS-2 OUNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska Public Power District Date August 30, 1989 i

,..(Name)

P.O. Box 49. Columbus, NE 68601 Sheet 19 of 39 (Address)

2. Plant.

Cooper Nuclear Station Unit' One (Name)

~

P.O. Box98, Brownville, NE:'68321~

N/A

~

(Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A' Same (Address)

Expiration Date N/A'

4. Identification of System Control Rod Drive (CRD)
5. (al Applicable'Constructi~on' Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b). Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 w;,h MO A/dda.
6. Identification of Components Repaired or Replaced and Replacement Components U rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stauped Component Manufacturer Class Number Replacement (Yes or No)

PSR-5 N/A 2

89-1548 Replacement No CRD-HHS N/A 2

89-1968 Replacement.

No CRD-BBS N/A 2

89-1968 Replacement No

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided -(1) size is 81" x 11", (2) information in items 1 5

through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

h

9. Remarks This NIS-2 Report provides the required information on repairs and' replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thie replacement conforms to the rules of the ASIfE Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A-Certificate of Authorization No.

N/A Expiration Date N/A F6% v\\Grt. Date 9

Signed

(_

~

(Owner or Owner's Designee, Title)

' CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province-of Nebrnskn and employed by Hartford Steam Boiler'I&I Co.

of unrtford_ CT have inspected the components described in this Owner's Report.during the period January 1989-to

. Tune 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,-Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning.the examinations and corrective measures described in this owner's Report. Furthermore, j

neither the Inspector nor his employer shall be liable in any manner for i

any personal injury or property damage or a. loss of any kind arising.from or connected with this inpsection.

1 Inspector's Signature M(

~

(H. B. Erb)

Commissions,

NB 8033 Nebr. 8033 (National Board, State Province, and Endorsements)

Date h-h-h

7

)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner' Nebraska Public Power District ~

Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 20 of 39 (Address)

2. Plant Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A ^

(Address)

(Repair Organization, P.O. No.

~

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A' Same (Address)

Expiration Date N/A

4. Identification of System Residual Heat Removal (RHR)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80

,vi, der riff Addadet.

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RH-H135 N/A 2

89-1968 Replacement No RH-H44A N/A 2

89-1968 Replacement No RH-H94A N/A 2

89-1968 Replacement No RH-H47A N/A 2

89-1968 Replacement No RH-H46 N/A 2

89-1968 Replacement No

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper N'u'c' lear Station f'om January, 1989 r

through June, 1989. Also Code Case N-308. " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports.to-be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the rep' ort are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A 0%. ML _Date fd Signed

(~)'

(Owner or Owner's Designee, Title) 1 CERTIFICATE OF INSERVICE INSPECTION 1

I I, the undersigned, holding a valid commission issued by the National-Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska

___ and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this owner's Report in accordance with the requirements of the ASNI Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, i

'neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature lN (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements) h-h-h Date

FORM HIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4

As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska Public Power District Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 21 of 39 (Address)

2. Plant

' Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A l

4. Identification of System Residual Heat Removal (RHR)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80

, RA te,,- (121 Addesla.

6. Identification of Components Repaired or Replaced and Replacement Components E"'

^"

Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RH-H25A N/A 2

89-1968 Repaired No RH-H41 N/A 2

89-2247 Repaired No RH-H54 N/A 2

89-2699 Repaired No

7. Description of Work: Added weld to reduce member stresses.
8. Tests Conducted: Hydrostatic

. Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I

2. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs'and Replacements of Components in Nuclear Power Plants", is invoked through i

the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached-CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A 9

63 Signed

()Oh - ~

GA %L Date (Owner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford. CT have inspected the components

' described in this owner's Report during the period -January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of

-the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and 4

corrective mea'sures described in this Owner's Report.

Furthermore, neither the Inspector nor his ecployer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature f[3$_f, l

(H. B. Erb) l' Commissions NB 8033 Nebr. 8033 (National Board, State Province, and Endorsements)

Date k-h b l

1 L__ _ _ __ _______

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska Public Power District Date August 30, 1989

-(Name)

P.O. Box 49, Columbus, NE 68601 Sheet 22 of 39 (Address)

2. Plant Cooper Nuclear Station Unit One (Name) l P.O. Box 98,'Brownville, NE 68321 N/A,

l (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System High Pressure Coolant Injection (HPCI)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 u; der I4f f Adhde.
6. Identification of Components Repaired or Replaced and Replacement Components Work Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

BS-H92 N/A' 2

89-1968 Replacement No HP-H26 N/A 2

89-1968 Replacement ik) l HP-H31 N/A 2

89-1968 Replacement No HP-S11 N/A 2

89-1968 Replacement No l

HP-H34 N/A 2

89-1968 Replacement No

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs

~

and replacements performed at Cooper Nuclear Sta' tion'from January, 1989-through June, 1989. Also Code Case N-308, " Documentation of' Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data > Reports;to be Attached CERTIFICATE OF COMPLIANCE We, certify that the statements made in the report are correct and this replacement

' conforms to the rules of the ASME Code, Section X1.

(repair or replacement)

Type' Code Symbol Stamp N/A' Certificate of Authorhation'No.

'.N/A Expiration Date N/A Signed

(~)

"

  • Dste M

(Owtier or Owner's Designee, Title) i I

CERTIFICATE OF INSERVICE INSPECTION I, the' undersigned, holding a valid commission issued by the National j

Board of Boiler and Pressure Vessel Inspectors and the State or Province l

ofi Nebraska- ~

and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that tolthe best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in.this Owner's Report in accordance with the requirements of the ASME Code Section XI.

-By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and l

conective measures described in this Owner's Report. Furthermore.

l neither the Inspector nor his-en loyer shall be liable in any manner for 1

any personal injury or property damage or a loss of any kind arising from

]

or connected with this inpsection.

Inspector's Signature N

j (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements)

J Date 9-hkN

[

i

.\\

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

[

As Required by the Provisions of the ASME Code Section XI

1. Owner Nebrask'a Public Power District Date August 30, 1989 (Name) 3 P.O. Box 49, Columbus, NE 68601 Sheet 23 of 39 (Aadress) l l
2. Plant Cooper Nuclear Station Unit One j

(Name) l-P.O. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

-3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System High Pressure Coolant Injection (HPCI)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Codd Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80, WMer t T 7f Addal8t.
6. Identification of Components Repaired or Replaced and Replacement Components Work Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

HP-S4 N/A 2

89-1968 Replacement No HP-H33A N/A 2

89-1968 Replacement No HP-H32A' N/A 2

89-1968 Replacement No HP-H41 N/A 2

89-2247 Replacement No l

HP-H23 N/A 2

89-2247 Replacement No

7. Description of Work: Added supports and modified support to reduce member stresses.
8. Te'sts Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81" x 11", (2) information in items 1 5

through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

[

t l.

9.' Remarks This NIS-2 Report provides the required information on repairs

{

l and replacements performed at Cooper Nuclear Station from January, 1989 I

through June, 1989. Also Code Case-N-308, " Documentation of Repairs and l

t 1

Replacements of Components in Nuclear Power Plants", is invoked through "the use of Form NIS-2 for reporting.

I l1 Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this

-replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certifica'te of Authorization No.

N/A Expiration Date N/A Signed as mA Date

,D1 (Ownsr or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and I

belief, the Owner has performed. examinations and taken corrective measures

]

described in this Owner's Report in accordance with the requirements of

{

the ASME Code,Section XI.

t By signing this certificate neither the Inspector nor his employer makes

)

any warranty, expressed or implied, concerning the examinations and I

corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature M

(H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements) k-b- h Date

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska Public Power District Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 24 of 39 (Address)-

2. Plant Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE ~ 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Main Steam (MS)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code' Case (b). Applicable Edition of Section XI Utilizpd for Repairs or Replacements 19 80, 9;Jer (f7/4//44f.
6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

MS-H113 N/A 2

89-1968 Replacement No MS-S75 N/A 2

89-1968 Replacement No MS-S20A N/A 2

89-1968, Replacement No MS-S20 N/A 2

89-1968 Replacement No MS-S18 N/A 2

89-1968 Replacement No l

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8h" x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from'J'anuary, 1989 through June, 1989. Also Code Case N-308, " Documentation of' Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached

' CERTIFICATE OF COMPLIANCE q

We certify that the statements made in the report are correct and this replacement

' conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A-Certificate of Authorization No.

N/A _ Expiration Date N/A 1

ffi Signed

% N L Date (0wher or Owner's Designee, Title)

)

i l

l l

CERTIFICATE OF INSERVICE INSPECTION l

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

-Nebraska-and employed by Hartford Steam Boiler I&I Co.

of Hartford. CT

_ have inspected the components described in this Owner's Report during-the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature

(

(H. B. Erb)

Commissions NB 8033 Nebr. 8033 i

(National Board, State, Province, and Endorsements)

Date h-h- N L_-__________________

FORM NZS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner' Nebraska Public Power District" Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 25 of 39 (Address)

2. Plant' Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Main Steam (MS)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 ts; der (4 91 AJ/A/s.

y

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear l

eP aced, or Stamped Cumen Component Manufacturer Class Number Replacement (Yes or No)

MS-S17 N/A 2

89-1968 Replacement No MS-SillA N/A 2

89-1968 Replacement No MS-S16A N/A 2

89-1968 Replacement No MS-H103 N/A 2

89-2247 Replacement No MS-H184 N/A 2

89-2247 Replacement No

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

\\

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989

.through June, 1989. Also Code Case N-308, " Documentation of Repairs'and Replacements of Components in Nuclear Power Plants", is invoked through

-the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached-i CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed

()

M M&v Date ffl 1

(Owder or Owner's Designee, Title) f CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

- Nebraska and employed by Hartford Steam Boiler 1&I Co.

)

of Hartford, CT have inspected the components described in this owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and l

belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of

~

the'ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

l Inspector's Signature I

(H. B. Erb) f Commissions NB 8033 Nebr. 8033 (National Board, State Province, and Endorsements) k-h-hh l

Date t

L__

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS l

As Required by the Provisions of the ASME Code Section XI 1

1. Owner Nebraska Public Power District Date August 30, 1989 (Name)-

P.O. Box 49, Columbus NE 68601 Sheet 26 of 39 (Address)

2. Plant Cooper Nuclear Station Unit One (Name)

P,0. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Main Steam (MS)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, S/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 Mder f($1 AMesda,
6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

MS-H101A N/A 2

89-1968 Repaired No

7. Description of Work: Removed lugs to reduce support member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

__'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A 9

63 Signed DM- %

cAG.m6L Date (OVner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore.

neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements)

Date h

  • h-

l FORM NIS-2 OWNER'S REPORT,FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1.' Ow' er Nebraska Public Power District Date AugustJO,1989 n

(Name)

P.O. Box 49, Columbus, NE 68601 Sheet 27 of 39 (Address)-

2. Plant Cooper Nuclear Station Unit

-One (Name)

P.O. Box 98, Brovnville, NE-68321 N/A (Address)

(Repair Organization, P.O. No.

Job lio. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Reactor Feedwater (RF)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No Addenda.

N/A Code Case (b) Applicable-Edition of Section XI Utilized for Repairs or Replacements 19 80, t.r,her 0%1 A a la h.

f

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RF-H42A N/A 2

89-1968 Replacement No RF-H55 N/A 2

89-1968 Replacement No RF-E46A N/A 2

89-1968 Replacement No RF-H48 N/A 2

89-2247 Replacement No RF-H53 N/A 2

89-2247 Replacement No

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs 1

i and replacements performed at Cooper Nuclear Stat' ion from January, 1989 1

through June, 1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached y

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this-

- replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A' Certificate of Authorizat' ion'No.

N/A Expiration Date N/A Signed M MUL Date SO 6I (Owner or Owner's Designee, Titic)

CERTIFICATE OF INSERVICE INSPE' TION C

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler'I&I Co.

of un,,rnva cm have inspected the components described in this Owner's Report during the period-January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and t

corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements) l Date

'h-@-@

a i

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska Public Power District Date August.30, 1989 (Name)

P.O. Box 49. Columbus, NE 68601 Sheet 28 of 39 (Address)

2. Plant Cooper Nuclear Station Unit 10ne (Name)

~P.0J Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Reactor Feedwater (RF)
5. (a) Applicable Construction Code ~

USAS B31.7 19 69

Edition, No
Addenda, N/A Code Case (b)ApplicableEditionofSectionXIUtilizpd.d for Repairs or Replacements 19 80 M d er 149f,4JdfA y
6. Identification of Components Repaired or Replaced and Replacement Components l

W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RF-S6 N/A 2

89-1968 Repaired No l

7. Description of Work:

Remove support.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

E________________

l

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manuf acturer s Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair _

conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed d

6M MW Date D

(Owner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to-the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature b

(H. b. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State. Province, and Endorsements)

Date k-h-h

FORM NIS-2 OWNER'S REPORT FOR REFAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Scction XI

1. Owner Nebraska Public Power District Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 29 of 39 (Address)

2. Plant' Cooper Nuclear Station Unit One (Name)

P.O.. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Reactor Feedwater (RF)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 Whter (47( Ad4*/8 7
6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name'of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RF-H41 N/A 2

89-2247 Replacement No RF-HS9 N/A 2

89-2247 Replacement No RF-H59A N/A 2

89-2699 Replacement No I

i

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l

l l

9. Remarks This NIS-2 Report provides the required information on repairs l.

and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Secticn XI.

(r epair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A M. M Signed M.fML, Date (Owner or Owner's Designee. Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of,_ Hartford, CT have inspected the components described in this Owner's Report during the period-January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore,

.neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature d

(H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State. Province, and Endorsements) h

  • h-h Date l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska Public' Power District' Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 30 of 39 (Address)

2. Plant Cooper Nuclear Station Unit One (Name) l

'P.O.' Box 98, Brownville, NE 68321' N/A l

(Address)

(Repair Organization, P.O. No.

Job'No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

'N/A Same (Address)

Expiration Date N/A

4. Identification of System Residual Heat Removal (RHR)
5. (a) ~ Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b). Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 ) wider (iSI /hMdd.
6. Identification of Componsats Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RH-S58 N/A 2

89-2247 Replacement No RH-H61 N/A 2

89-2247 Replacement No RH-S10 N/A 1

89-2247 Replacement No RH-S9 N/A 1

89-2247 Replacement No RH-H27B N/A 2

89-2247 Replacement No

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supp3/ mental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11",- (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9

9. Remarks-This NIS-2 Report provides the required information on' repairs and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A l

Certificate of Authorization No.

N/A Expiration Date N/A Signed

(

V~

O h MGL Date 9C (Owner or Owner's Designee. Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&_I__Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to _ June 1989

. and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature lM (H. B. Erb) l-Commissions NB 8033 Nebr. 8033

(

(National Board, State, Province, and Endorsements)

Date h-b -

4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS l

As Required by the Provisions of the ASME Code Section XI j

1.'Ovner Nebraska Public Power' District Date August 30, 1989

~

(Name)

P.O. Box 49, Columbus, NE 68601 Sheet 31 of 39 (Address) i i

2. Plant Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville.-NE 68321 N/A

~

(Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Residual Heat Removal (RHR)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Coda Case (b) Applicable Edition of Section XI Utilized for Repairs or uger tett tythwAa, Replacements 19 80 y
6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RH-H22A N/A 2

89-2247 Replacement No RH-S32 N/A 2

89-1968 Replacement No RH-H41A N/A 2

89-1968 Replacement No

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 1e 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs and r'eple' cements performed at Cooper N' clear Station.from January,1989 u

through June,~1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this

-replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A

~

Certificate of' Authorization No.

N/A Expiration Date N/A Signed ((O JK6 mt Date 0 6*l (Owner or Dener's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of' Nebrnekn and employed by Unrtfnra 9tonm Rn11nr T&T Co.

of unternra, cr have inspected the components described in this Owner's Report during the period annunty 1989 l

to June 1989

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective meaq.ures l

described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures-described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature

.fIhb(__r (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State. Province, and Endorsements)

Date 9-h- h

b e

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner-Nebraska Public Power District Date-August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 32 of, 39 (Address)

2. Plant Cooper Nuclear Station Unit-One l

(Name)

'P.O. Box 9".f 3rownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration'Date N/A

4. Identification of System Reactor Core Isolation Cooling (RCIC)
5. (a) Applicable Construction Code USAS B31.7 19 69 Edition.

-No

Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 Mder IT9f Admda.

y

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RC-H10 N/A 2

89-2247 Replacement No

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi. Test Temp.
  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

[

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs'and l

Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to.be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A -

N/A Certificate of Authorization No.

N/A Expiration Date __

Signed h

.J, et. Date D 63 (Owner or Owner's Designee, Title) l l

l CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler.and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during tfie period January 1989 to June 1989

, and state that to the besc of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes l

any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's' Signature kk (H. B. Erb)

Commissions' NB 8033 Nebr. 8033 (National Board, State Province, and Endorsements)

Date k-h-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska Public Power District Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 33 of __

39 (Address)

2. Plant Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A 4.' Identification of System Main Steam (MS)

5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilize 4 for Repairs or Replacements 19 80 ) ragtev I457 A//rtde.
6. Identification of Components Repaired or Replaced and Replacement Components "E#

^

Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

MS-S16 N/A 2

89-2247 Replacement No MS-HIC 7A N/A 2

89-2699 Replacement No l

7. Description of Work: Modify support to reduce member stresses.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F 3

l NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on'this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

t

e l

9. Remarks This NIS-2 Report provides the required information on repairs

^and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Cod'e Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this, replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed h

W 4 MUL. Date 0 6cg l

(Owner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors end the State or Province j

of' Nebraska and employed by Hartford Steam ~ Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belie 1, the owner has performed examinations and taken corrective measures described in this Owner's Report in acccrdance with the requirements of the ASME Code,Section XI.

-By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature k[

(H. B. Erb) i Commissions NB 8033 Nebr. 8033 (National Board, State Province, and Endorsements)

Date Q-O-hi 1

d FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebraska'Public Power District

~'Date August'30, 1989

~

(Name)

P.O. Box 49, Columbus, NE 68601 Sheet 34 of 3

(Address) 2.. Plant!

Cooper Nuclear. Station Unit-One (Name)

P.O. Box 98, Brownirille,'NE 68321' N/A~

(Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By ownen Type Code Symbol Stamp N/A (N'ad Authorization No.

N/A' Same (Address)

~

Expiration Date N/A

4. Identification of System High Pressure Coolant Injection.(HPCI)
5. (a) Applicable Construction Code' USAS B31.7' 19 69
Edition, No

' Addenda, N/A Code Case (b)-Applicable Edition of Section XI Utilized.for Repairs-or

) u; der Iqp( AMds.

Replacements 19 80

6. Identification of Components Repaired or Replaced and Replacement Components rk Repaired ASME Code Name of Name of Nuclear

. Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

HP-H7A N/A 2

89-2247 Repaired No

7. Description of Work: Support removed.
8. Tests Conducted:

Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be l

used, provided (1) size is 8 " x 11", (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

lL__-_

4 t

a

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989 i

~

through June, 1989. Also Code Case N-308, " Documentation of Repairs'and j

Replacements of Components in Nuclear Power Plants", is invoked through the use of Fonn NIS-2 for reporting.

Applicable Manufacturer's Data Reports to..be Attached; CERTIFICATE OF COMPLIANCE l

We. certify that the statements made in the report are correct and this repair-conforms to the rules of the ASME Code Section XI.

(repair or replacement)

]

Type Code Symbol Stamp N/A' Certificate of' Authorization No.

N/A Expiration Date N/A Signed HON Nps. t%t. Date (Owner or Owner's Designee, Title)

CERTIFICATE 0F INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of.

Nebra sk a -

and employed by Hartford Steam Boiler I&I Co.

of Hartford. CT have inspected the components

-described in this owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and I

corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for

]

any personal injury or property damage or a loss of any kind arising from l

or connected with this inpsection.

1 Inspector's Signature (H. B. Erb)

Commissions NB 8033 Nebr. 8033 p

(National Board, State. Province, and Endorsements)

Date k -h-h r

L_ _-.- - - _ - - - - - - - _ - - - - - - - - - _ - - - - - - - - - - _ _ _ _ _ _ - - - - - - - - _ _ - - _ _ _ _ _ - - - - - - - - _ - - _ _ - - - _ - - - _ - _ _ _ - - _ _ - _ _ _ _ - - _ _ - _ _ _ _

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

'As Required by the Provisions of the ASME Code Section XI l'. Owner Nebrasia Pu'blic Power District Date August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 35 of 39 (Address)

2. Plant-Cooper Nuclear Station Unit One (Name)

P.O. Box 98, Brownville, NE 68321-N/A (Address)

(Repair Organization, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A l

4. Identification of System Reactor Recirculation (RR)
5. (a) Applicable Construction Code USAS B31.7 19 69
Editiors, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or y hiter 1431 A /deuds.

Replacements 19_80 L

+

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component

~ Manufacturer Class Number Replacement (Yes or No)

RR-H20A N/A 1

89-2699 Replacement No t

7. Description of. Work: Added new support.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2). information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

_amm- - - - _ _ _-___

y_____,_--.

i p

l c

i:

(

9. Remarks This NIS-2 Report provides the required information on repairs 1

and replacements pe'rformed at Cooper Nuclear' Station'from January, 1989

~

through June, 1989. Also Code Case-N-308, " Documentation of Repairs'end Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp -

N/A Certificate of Authorization No.

N/A Expiration Date N/A f

kOM Signed [O

% wR - Date (Owner or Owner's Designee. Title)

"~

CERTIFICATE OF ItSERVICE INSPECTION EI, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraskn and employed by Mnrrfnrd 9tonm Rnfinr T&T Co.

of unvernra. cr have inspected the components described in this Owner's Report during the period ynrnnry igng

~

to J1ing 1999

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be-liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature N

(H. B. Erb)

Commissions NB N'03 Nebr. 8033 (National Board, State, Province, and Endorsements)

Date Q-8-87

o FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Nebr~ska Public~ Power District Date August 30, 1989 a

(N ame) 4 P.O. Box 49, Columbus, NE 68601 Sheet 36 of 39

- (Address)

2. Plant Cooper Nuclear' Station Unit.

One.

(Name)

P.O. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization. P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A (Name)

Authorization No.

N/A

~

Same (Address)

Expiration Date N/A

4. Identification of System Control Rod Drive (CRD)
5. (a) Applicable Construction Code USAS B31.7 19 69
Edition, No
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement 19 80 wtd<r /T7fA/tk'/#.
6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

CRD-EES N/A 2

89-2699 Repaired No CRD-EEN N/A 2

89-2699 Repaired No

7. Description of Work: Added welds to reduce support member stresses.

l l

8. Tests Conducted: Hydrostatic Pneumatic l

Nominal Operating Pressure Other Pressure psi Test Temp.

  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items I through 6 on this report is included on each sheet, anj (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs l

l and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs and

, Replacements of Components in Nuclear Power Plants", 1s. invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached-l l

CERTIFICATE OF COMPLIANCE l

We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code,Section XI.

(repair or replacement) l Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed f

W*%L-Date 6 69 (Owner or Owner's Designee, Title)

)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

I of Hartford, CT have inspected the components described'in this Owner's Report during the period January 1989 to June 1989

. and state that to the best of my knowledge and

- belief, the Owner has per. uned examinations and taken corrective measures described in this Owner's Report in accordance with the requirert.ents of l-the ASME Code,Section XI.

j By signing this certificate neither the Inspector nor his employer makes j

any warranty, expressed or implied, concerning the examinations and 1

corrective measures described in this Owner's Report. Furthermore, i

neither the Inspector nor his employer shall be liable in any manner for l

any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature

(

)

(H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State. Province, and Endorsements)

Date 9-b-

O.

p FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS l

As Required by the Provisions of the ASME Code Section XI 1.lDvner' Nebiaska'Public Power District

'Date ~

August' 30, 1989 (Name)

P.O. Box 49. Columbus, NE 68601 Sheet 37 of 39 (Address)-

2. Plant- -

Cooper-Nuclear Station Unit One (Name)

~P.O. Box 98, hrownville, NE 68321' N/A

~

' (Address)

(Repair Organization, P.O. No.

Jcb No. Etc.)

3. Work Performed By Dwner Type Code Symbol Stamp N/A (Name)

Authorizat' ion No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Reactor Water Cleanup (RWCU)
5. (a) Applicable Construction' Code USAS B31.7 19 69
Edition,

-No-

Addenda, N/A Code Case (b) Applicable Edition of Section-XI Utiliged for Repairs or Replacements 19 80

,Wei,e M9f A//eus.

6. Identification of Components Repaired or Replaced and Replacement Components W rk Eepaired ASME Code Name of Nace of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

CWA-CF-40 N/A 2

89-1965 Replacement No CWA-CF-43 N/A 2

89-1965 Replacement No CWA-CF-44 N/A 2

89-1965 Replacement No

'7. Description of Work: Replaced section of pipe and fittings that included these welds.

8. Tests Conducted: Hydrostatic X

Pneumatic Nominal Operating Pressure Other Pressure 1570 psi Test Temp. Ambient *F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs

~

~

and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. -Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed f

- Er 1 M6 L Date D 63 (Owner or Owner's Designee. Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned,-holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

. and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective-measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be-liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State Province, and Endorsements)

)

k-h-h Date

.l

o FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

.l 8

As Required by the Provisions of the ASME Code Section XI l'.' Owner Nebr'aska Public Power' District Date August 30', 1989

~

(Name)-

P.O. Box 49, Columbus, NE 68601 Sheet 38 of 39 (Address)-

2. Plant -

Cooper Nuclear Stat! ion Unit-One (Name)

P.O.' Box 98', Brownvil'le, NE 68321 N/A

(

(Address)

. Repair Organization _, P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A

.(Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System Reactor Water Cleanup (RWCU)

~

5. (a)~ Applicable Cons'ruction Code USAS B31.7 19 69 Edition.

t No

Addenda, N/A Code Case (b) Applicable Edition of Section XI Ut ed for Repairs or -

Replacements 19 80 6J.dce fiff M y

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code' Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

RWCU-13 N/A 2

89-2182 Repaired No RWCU-26 N/A 89-2183 Repaired No

7. Description -of Work: Repair IGSCC indications in RWCU welds.
8. Tests Conducted: Hydrostatic X

Pneumatic Nominal Operating Pressure Other Pressure 1565 psi Test Temp. Ambient *F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This NIS-2 Report provides the required information on repairs and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", ic invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports.to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp-N/A Certificate of Authorization No.

N/A Expiration Date N/A Of69 Signed il M N%L-Date (Owner or Owner's Designee,'litle)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by Hartford Steam Boiler I&I Co of Hartford, CT have inspected the components described in this Owner's Report during the period January 1989 to June 1989

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and j

corrective measures described in this Owner's Report. Furthermore, i

neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

l Inspector's Signature r--

(H. B. Erb) l Commissions NB 8033 Nebr. 8033 l

(National Board, State, Province, and Endorsements) 1 Date h-h- N

L r

2 l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS f.

As Required by the Provisions of the ASME Code Section XI

^

1.' Owner Nebraska Public Power D'istrict Date

~ August 30, 1989 (Name)

P.O. Box 49, Columbus, NE 68601 Sheet 39 of 39 (Address).

2. Plant Cooper Nuclear Station <

Unit One (Name)

P.O. Box 98, Brownville, NE 68321 N/A (Address)

(Repair Organization P.O. No.

Job No. Etc.)

3. Work Performed By Owner Type Code Symbol Stamp N/A

,(Name)

Authorization No.

N/A Same (Address)

Expiration Date N/A

4. Identification of System High Pressure Coolant Injection (HPCI)

~

5. (a) Applicable Construction Code ANSI B31.7 19 69
Edition,

-No

Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized.for Repairs or Replacements 19 80 U;4rr liff /t/ ALM.

7

6. Identification of Components Repaired or Replaced and Replacement Components W rk Repaired ASME Code Name of Name of Nuclear Document Replaced, or Stamped Component Manufacturer Class Number Replacement (Yes or No)

HPCI-RO-132 N/A 2

89-1688 Replacement No HPCI-RO-133 N/A 2

89-1688 Replacement No HPCI-RO-134 N/A 2

89-1688 Replacement No

7. Description of Work: Replace orifice.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure _ X Other Pressure 150 psi Test Temp. Ambient *F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 " x 11", (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l l _

__________-___-___________-________________________Q

4 s

9. Remarks This NIS-2 Report provides the required information on repairs

~

and replacements performed at Cooper Nuclear Station from January, 1989 through June, 1989. Also Code Case N-308, " Documentation of Repairs and Replacements of Components in Nuclear Power Plants", is invoked through the use of Form NIS-2 for reporting.

Applicable Manufacturer's Data Reports to be Attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

(repair or replacement)

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A

.igned hh-SM v4GL Date O l (Owner or Owner's Designee, Title)

CERTIFICATE OF INSERVICE INSPECTION

- I, the undersigned, holding a valid commission issued by the National Board of Boiler and I ssure Vessel Inspectors and the State or Province of Nebraska

,and employed by Hartford Steam Boiler I&I Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period ____ January 1989 to June 1989

, and state that to the best of my knowledge and belief the Owner has performed examinations and taken corrective measures described in this owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inpsection.

Inspector's Signature h

y (H. B. Erb)

Commissions NB 8033 Nebr. 8033 (National Board, State, Province, and Endorsements) k-h- b Date

_ _ _ _ _. _ _ _ _ _ _ _ _ _ _