ML20236L558

From kanterella
Jump to navigation Jump to search
Discusses Ph Johnson of Region V Ltr Requesting NRR Interpretation of Applicability Footnote Re Several Containment TS for BWRs
ML20236L558
Person / Time
Issue date: 07/26/1994
From: Charemagne Grimes
Office of Nuclear Reactor Regulation
To: Quay T
Office of Nuclear Reactor Regulation
Shared Package
ML20236J990 List: ... further results
References
FOIA-98-155 NUDOCS 9807130070
Download: ML20236L558 (1)


Text

_ - _-_-_ _

1 l

l l

' l, h, l'.1 MEMORANDUM FOR:

Theodore R. Quay, Pro; Director V, PD5 Division of Reactor.'roje ts, NRR FROM:

Christopher I. Gr* mas, Chief Technical Specifications Branch Division of Op<r.,'ing Reactor Support, NRR

SUBJECT:

CONTAINMENT b flh PoiENTIAL FOR DRAINING THE REACTOR VESSEL By note of June 3, 1993. Phillip H. Johnson, Region V, requested NRR's interpretation of an APPL!r ABILITY footnote that applies to several containment Technical Specif44tions far BWRs. The footnote is "when l

irradiated fuel is being handled in ti.e secondary containment and during CORE All[RA110NS and operation? with a potential for draining the reactor vessel."

At issue is the use of the phrase " operations with a potential for draining the reactor vess.

In the 15, the -

i

  • potential" means "something that exists in a state of potency or possib ity for changing or developing into a state of actuality."

It follows from this definition that even thnugh features are provided to prevent draining the reactor vessel, the potential for such draining can continue to exist.

The operation described was the use of the residual heat removal (RHR) sy tem to lower the water level in the reactor cavity. Two independent s.ction valves.rere designed to satomatically isolate at a specified water level. However, since the failure of both is possible, this is an "operatson with a potential for :frain mq the reactor vessel."

If a licensee believes that any conditio-dtscribeu by *noerat tuns

."h a

potenttal for draining the reactor vessel" shou'. not require the establishment of secondary containment, a request for change along with justification (e.g., compensatory action) should be made i the staff.

f. good avenue to propose the change is through the Owners Groups in the implementation of improved Standard Technical Specifications.

s o:n. c :, P m v. o. t" Christopher.1. Grimes, Chief Technical Specifications Branch Division of Operating Reactor Support, NRR DISTRIBUTION:

N entral files 0158 R/f DORS R/F C

BKGrimes SHWeiss AEthaffee i

GHMarcus CIGrimes RJBarrett RCJones RHLo CWMoon Clifford JBradfoote CSSchulten l

l l

See Previous Concurrence DOCUMENT NAME: G: DRAIN.CWM i

t!

l OTSB: DORS:NRR O1SB: DORS:NRR SXRB:NRR SCSR:NRR C:01SB: DORS:pRR

/1 l

CWMoon*

RHLo*

RCJones*

RJBarrett' f)ilGrknet, M r N}'

06/22/93 06/22/93 06/24//93 06/21/93 y07/gf93 8'

.t PDR FOIA b

9807130070 980624 UNNERST98-155 PDR tov n P v'"

./