|
---|
Category:LICENSE
MONTHYEARML20210E9621999-07-23023 July 1999 Amend 17 to License SNM-1227 for Siemens Power Corp,Allowing Storage of Moderated Uranium Compounds in sea-land Containers ML20206L5471999-05-11011 May 1999 Amend 16 to License SNM-1227 for Siemens Power Corp ML20198M9011998-12-23023 December 1998 Amend 15 to License SNM-1227 for Siemens Power Corp ML20151W9801998-09-0202 September 1998 Amend 14 to License SNM-1227 for Siemens Power Corp ML20151X0031998-09-0101 September 1998 Amend 13 to License SNM-1227 for Siemens Power Corp ML20248D8501998-05-21021 May 1998 Amend 12 to SNM-1227 for Siemens Power Corp ML20248E0841998-05-18018 May 1998 Amend 11 to License SNM-1227 for Siemens Power Corp ML20217A9291998-03-17017 March 1998 Amend 10 to License SNM-1227 for Siemens Power Corp ML20198Q1401998-01-15015 January 1998 Amend 9 to License SNM-1227 for Siemens Power Corp ML20203C2401997-12-0909 December 1997 Amend 8 to License SNM-1227 for Siemens Power Corp ML20198K1361997-10-0303 October 1997 Amend 7 to License SNM-1227 for Siemens Power Corp, Authorizing Organizational Changes ML20211G9271997-09-23023 September 1997 Amend 6 to License SNM-1227 for Siemens Power Corp ML20216J6521997-08-29029 August 1997 Amend 5 to License SNM-1227,authorizing Organizational Changes to Facilities at Richland,Wa ML20141J6011997-08-18018 August 1997 Amend 4 to License SNM-1257 for Siemens Power Corp ML20149J0281997-07-18018 July 1997 Amend 3 to License SNM-1227 for Siemens Power Corp ML20148N5831997-06-25025 June 1997 Amend 2 to License SNM-1227 for Siemens Power Corp, Incorporating Changes to Fundamental Nuclear Matl Control Plan ML20141E9021997-05-16016 May 1997 Amend 1 to License SNM-1227 for Siemens Power Corp to Use U & Pu at Licensees Existing Facilities at Richland,Wa ML20134L9941996-11-15015 November 1996 Amended License SNM-1227 for Siemens Power Corp ML20059D0041993-10-29029 October 1993 Amend 21 to License SNM-1227,authorizing Rev to Audits & Insps Responsibilities Under Section 2.6.5 of License ML20057F3461993-10-13013 October 1993 Amend 20 to License SNM-1227,removing Specific Ref to Latest Rev of Emergency Plan ML20057F5301993-10-0808 October 1993 Amend 19 to License SNM-1227 for Siemens Power Corporation ML20056H2341993-09-0303 September 1993 Amend 18 to License SNM-1227,authorizing Changes in Environ Monitoring Program ML20245J2541989-08-11011 August 1989 Amend 4 to License SNM-1227 for Advanced Nuclear Fuels Corp, Revising Conditions 6,7 & 8 to Reflect New Possession Limits & Condition 9 to Include Date of 890401 for Revised Radiological Contingency Plan ML20236A9061989-03-0808 March 1989 Amend 3 to License SNM-1227 for Advanced Nuclear Fuels Corp,Revising Condition 9 to Include Date of 881220 Re Contamination Limit for Cloth Protective Clothing ML20151V8801988-04-22022 April 1988 Amend 2 to License SNM-1227 for Advanced Nuclear Fuels Corp, Authorizing Use of U-235 & Plutonium & Revising Condition 9 Re Authorized Use ML20147A8341988-01-0404 January 1988 Amend 1 to License SNM-1227,authorizing Use of Enriched U-235 & Pu Sealed Sources Per Part I of Licensee Application Dtd July 1987 & 871112 Suppl ML20239A1861987-09-10010 September 1987 Renewal of License SNM-1227 for Advanced Nuclear Fuels Corp, Authorizing Use of U-235 & Pu in Sealed Sources & Pu Dioxide or UO2 Stored Waste ML20236D2891987-05-0101 May 1987 Amend SG-2 to License SNM-1257 for Advanced Nuclear Fuels Corp,Adopting Revised Fundamental Nuclear Matl Control Plan 1999-07-23
[Table view] Category:SNM & AMEND TO LICENSE (DKT 70S)
MONTHYEARML20210E9621999-07-23023 July 1999 Amend 17 to License SNM-1227 for Siemens Power Corp,Allowing Storage of Moderated Uranium Compounds in sea-land Containers ML20206L5471999-05-11011 May 1999 Amend 16 to License SNM-1227 for Siemens Power Corp ML20198M9011998-12-23023 December 1998 Amend 15 to License SNM-1227 for Siemens Power Corp ML20151W9801998-09-0202 September 1998 Amend 14 to License SNM-1227 for Siemens Power Corp ML20151X0031998-09-0101 September 1998 Amend 13 to License SNM-1227 for Siemens Power Corp ML20248D8501998-05-21021 May 1998 Amend 12 to SNM-1227 for Siemens Power Corp ML20248E0841998-05-18018 May 1998 Amend 11 to License SNM-1227 for Siemens Power Corp ML20217A9291998-03-17017 March 1998 Amend 10 to License SNM-1227 for Siemens Power Corp ML20198Q1401998-01-15015 January 1998 Amend 9 to License SNM-1227 for Siemens Power Corp ML20203C2401997-12-0909 December 1997 Amend 8 to License SNM-1227 for Siemens Power Corp ML20198K1361997-10-0303 October 1997 Amend 7 to License SNM-1227 for Siemens Power Corp, Authorizing Organizational Changes ML20211G9271997-09-23023 September 1997 Amend 6 to License SNM-1227 for Siemens Power Corp ML20216J6521997-08-29029 August 1997 Amend 5 to License SNM-1227,authorizing Organizational Changes to Facilities at Richland,Wa ML20141J6011997-08-18018 August 1997 Amend 4 to License SNM-1257 for Siemens Power Corp ML20149J0281997-07-18018 July 1997 Amend 3 to License SNM-1227 for Siemens Power Corp ML20148N5831997-06-25025 June 1997 Amend 2 to License SNM-1227 for Siemens Power Corp, Incorporating Changes to Fundamental Nuclear Matl Control Plan ML20141E9021997-05-16016 May 1997 Amend 1 to License SNM-1227 for Siemens Power Corp to Use U & Pu at Licensees Existing Facilities at Richland,Wa ML20134L9941996-11-15015 November 1996 Amended License SNM-1227 for Siemens Power Corp ML20059D0041993-10-29029 October 1993 Amend 21 to License SNM-1227,authorizing Rev to Audits & Insps Responsibilities Under Section 2.6.5 of License ML20057F3461993-10-13013 October 1993 Amend 20 to License SNM-1227,removing Specific Ref to Latest Rev of Emergency Plan ML20057F5301993-10-0808 October 1993 Amend 19 to License SNM-1227 for Siemens Power Corporation ML20056H2341993-09-0303 September 1993 Amend 18 to License SNM-1227,authorizing Changes in Environ Monitoring Program ML20245J2541989-08-11011 August 1989 Amend 4 to License SNM-1227 for Advanced Nuclear Fuels Corp, Revising Conditions 6,7 & 8 to Reflect New Possession Limits & Condition 9 to Include Date of 890401 for Revised Radiological Contingency Plan ML20236A9061989-03-0808 March 1989 Amend 3 to License SNM-1227 for Advanced Nuclear Fuels Corp,Revising Condition 9 to Include Date of 881220 Re Contamination Limit for Cloth Protective Clothing ML20151V8801988-04-22022 April 1988 Amend 2 to License SNM-1227 for Advanced Nuclear Fuels Corp, Authorizing Use of U-235 & Plutonium & Revising Condition 9 Re Authorized Use ML20147A8341988-01-0404 January 1988 Amend 1 to License SNM-1227,authorizing Use of Enriched U-235 & Pu Sealed Sources Per Part I of Licensee Application Dtd July 1987 & 871112 Suppl ML20239A1861987-09-10010 September 1987 Renewal of License SNM-1227 for Advanced Nuclear Fuels Corp, Authorizing Use of U-235 & Pu in Sealed Sources & Pu Dioxide or UO2 Stored Waste ML20236D2891987-05-0101 May 1987 Amend SG-2 to License SNM-1257 for Advanced Nuclear Fuels Corp,Adopting Revised Fundamental Nuclear Matl Control Plan 1999-07-23
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARML20210N9351999-08-0606 August 1999 Application for Amend to License SNM-1227,including Fuel Svcs Bldg as Specific Location for Authorized Activities with Special Nuclear Matl as Described ML20210E9621999-07-23023 July 1999 Amend 17 to License SNM-1227 for Siemens Power Corp,Allowing Storage of Moderated Uranium Compounds in sea-land Containers ML20209H3441999-07-14014 July 1999 Revised License Application Page 1-11 to 990527 License Amend Application Re Storage of U Compounds in sea-land Containers.Authorized Activities for Modular Extraction Recovery Facility,Previously Approved Inadvertently Deleted ML20207E1521999-05-27027 May 1999 Application for Amend to License SNM-1227,changing Authorized Activity for sea-land Containers from U Oxide to U Compounds ML20196L2601999-05-19019 May 1999 Application for Amend to License SNM-1227,requesting as Authorized Activity,Sale of Ammonium Nitrate/Ammonium Hydroxide Solution for Use as Fertilizer ML20206L5471999-05-11011 May 1999 Amend 16 to License SNM-1227 for Siemens Power Corp ML20207G7711999-01-31031 January 1999 Application for Renewal of SNM-1227,comprised of Rev 41 to EMF-2 ML20199H0021999-01-21021 January 1999 Application for Amend to License SNM-1227,including,as Authorized Activity,Storage of Moderated SNM in sea-land Containers with Storage Grids Fastened to Floors ML20198M9011998-12-23023 December 1998 Amend 15 to License SNM-1227 for Siemens Power Corp ML20195F8091998-11-13013 November 1998 Application for Amend to License SNM-1227,allowing Licensee to Process Uranium for DOE Project,Which Contains Up to 50 Bq/Gu of Alpha Activity from Pu & Neptunium (Transuranics) ML20151W9801998-09-0202 September 1998 Amend 14 to License SNM-1227 for Siemens Power Corp ML20151X0031998-09-0101 September 1998 Amend 13 to License SNM-1227 for Siemens Power Corp ML20248K2111998-05-29029 May 1998 Application for Amend to License SNM-1227,Part 1,changing Description of Area Where UF6 Cylinders Are Stored,Adding Filter Presses to Table 1-4.1 Along W/Types of Criticality Controls That May Be Employed & Sale of Ammonium Hydroxide ML20248D8501998-05-21021 May 1998 Amend 12 to SNM-1227 for Siemens Power Corp ML20248E0841998-05-18018 May 1998 Amend 11 to License SNM-1227 for Siemens Power Corp ML20217J1291998-04-23023 April 1998 Application for Amend to License SNM-1227,revising Section 5.1.2 to Account for Change.Encl in Support of Request of Revised Page 5-3 W/Changes Denoted by Vertical Lines in Right Margin ML20217A9291998-03-17017 March 1998 Amend 10 to License SNM-1227 for Siemens Power Corp ML20199L8831998-01-28028 January 1998 Rev 40 to EMF-2, Application for Renewal of License SNM-1227, Which Includes Changes to Part II of License ML20198Q1401998-01-15015 January 1998 Amend 9 to License SNM-1227 for Siemens Power Corp ML20199E8131997-12-23023 December 1997 Application for Amend to License SNM-1227,comprising of Rev 39 to EMF-2 ML20203C2401997-12-0909 December 1997 Amend 8 to License SNM-1227 for Siemens Power Corp ML20198K1361997-10-0303 October 1997 Amend 7 to License SNM-1227 for Siemens Power Corp, Authorizing Organizational Changes ML20211G9271997-09-23023 September 1997 Amend 6 to License SNM-1227 for Siemens Power Corp ML20210U3631997-09-0404 September 1997 Application for Renewal of License SNM-1227,comprising Rev 37 to EMF-2 ML20216J6521997-08-29029 August 1997 Amend 5 to License SNM-1227,authorizing Organizational Changes to Facilities at Richland,Wa ML20141J6011997-08-18018 August 1997 Amend 4 to License SNM-1257 for Siemens Power Corp ML20217M2191997-08-0404 August 1997 Application for Amend to License SNM-1227,adding Cylinder Recertification Facility as Location of Authorized Activity ML20149J0281997-07-18018 July 1997 Amend 3 to License SNM-1227 for Siemens Power Corp ML20141H0611997-07-15015 July 1997 Application for Amend to License SNM-1227,adding Use of Neutron Absorber as Criticality Safety Control in Smaller than Five Gallon Containers ML20149E8861997-07-14014 July 1997 Application for Amend to License SNM-1227,adding Operations Scrap Warehouse to Table I-1.1 as Specific Location of Authorized Activity Being Storage of Scrap & Product Containers Into Shipping Containers.Drawings Encl ML20148N5831997-06-25025 June 1997 Amend 2 to License SNM-1227 for Siemens Power Corp, Incorporating Changes to Fundamental Nuclear Matl Control Plan ML20148M0461997-06-0404 June 1997 Application for Amend to License SNM-1227,revising Pages 3-4 ML20148G5131997-05-22022 May 1997 Application for Amend to License SNM-1227,including Revised Table 1-4.1 of License Application,Descibing Use of Mechanical Neutron Absorbers in Approx Three & one-half Gallon Inner Containers Outside of Shipping Containers ML20141E9021997-05-16016 May 1997 Amend 1 to License SNM-1227 for Siemens Power Corp to Use U & Pu at Licensees Existing Facilities at Richland,Wa ML20138A4861997-04-15015 April 1997 Application for Amend to License SNM-1227,providing Summaries of Criticality SAs for Rod Fabrication,Bundle Assembly,Line 1 Process Offgas Sys & Line 2 Pog ML20135E3851997-02-21021 February 1997 Application for Amend to License SNM-1227,authorizing Max Batch Size for Release of Hydrofluoric Acid Mfg by Dry Conversion Process to Be Increased from 20,000 Liters to 46,000 Liters ML20135E6221996-11-30030 November 1996 Application for Renewal of License SNM-1227,to Possess U-235 & Pu ML20134L9941996-11-15015 November 1996 Amended License SNM-1227 for Siemens Power Corp ML20134F8251996-10-28028 October 1996 Application for Amend to License SNM-1227,changing Various Page Dates to Common One So That Single Application Date Can Be Ref in License ML20058Q3101993-12-10010 December 1993 Application for Amend to License SNM-1227,to Add Organizational Responsibilities of Manager,Waste Mgt Engineering Manager,Analytical Lab in Section 2.1 of Chapter 2 ML20059D0041993-10-29029 October 1993 Amend 21 to License SNM-1227,authorizing Rev to Audits & Insps Responsibilities Under Section 2.6.5 of License ML20057F3461993-10-13013 October 1993 Amend 20 to License SNM-1227,removing Specific Ref to Latest Rev of Emergency Plan ML20057F5301993-10-0808 October 1993 Amend 19 to License SNM-1227 for Siemens Power Corporation ML20058P1771993-10-0505 October 1993 Revised Page 8-1 to License SNM-1227 & 920826 Renewal Application,Reflecting That Emergency Plan Shall Be Submitted to NRC Headquarters (Hq) Region Ofc & That Recipient for Hq Copy to Changed to Director of NMSS 1999-08-06
[Table view] |
Text
..
I fmam M N M* M M m/EE Tmm.mm ashmmma mmgy 4 'l '
j ' HRC FOAM 374 " 1 #
l ~
po.eg u.S. NUCLEAR QEGULAToRY CoMMIS$loN #"j
- s MATERIALS LICENSE . 's 1 :D l j Purwant to the' Atomic Energy Act of 1954, as amended, the Energy Reo;ganization Act of 1974 :Public law 93-438), and Title 10, y 1 Ccde of Rderal Regulatiors, Chapter 1, Parts 30, 31, 32, 33, 34. 35, 39,40 and 70, and in reliance on statements and representations heretofore p-j made by the licensee. a liceme is hereby inued authorizing the licensee to receive, acquire, poness, and transfer byproduct, source, and special N 5 nuclear material designated below; to use such material for the purpose (s) and at the pixc(s) designated below; to deliver or transfer such material N-q to persons authorized to receive it in accordance with the regula' ions of the applicable Pan (s). This license shall be deemed to conuin the conditions :
i.pexified in Section 183 of the Atomic Energy Act of 1954, as amended, and is subject to all applicable rules, reguinions and orders of the Nuclear g
}
j Regulatory Comminion now or hereafter in effect and to any conditions spr:cified below, ig; t !)
ft j beensee
- p j
- 1 g 1 Siemens Power Corporation SNM-1227 I
- 3. Ucense number j 1. Amendment 10 IE j I 2101 Hom Rapids Road 1
] (f.
2-
- Richland, WA 99352-0130 November 30,2001
- 4. Expiration date
- 5. Docket or 70-1257 ,1 Reference No p i
1 E 13yproduct, source, and/or 7. Chemical and/or physical 8. Maximum amount that licensee f I speciai nuclear material form may possess at any one time f,F under this license 1 .B :
.1 it:
L A. Uranium enriched A. Any A. 350 g U-235 A l in U 235 4 lj l
}
g B. Uranium enriched up to 5.00 wt % U-235
- 8. Uranium compounds
- 8. 25,000 kg U-235 k[
,k E
l 1 C. Plutonium C. Sealed sources C. 1 mg Pu and not more >
and standards than 1.5 millicuries {f
't
'I D. Plutonium D. PuO2-UO2 D. 500 g Pu lt f[J stored waste li h
1
- 9. Authorized place of use: The licenree's existing facilities at Richland, Washington.
I
- 10. This license shall be deemed to contain two sections: Safety Conditions and Safeguards Conditions. These sections are part of the license, and the licensee is subject to compliance f'I with all listed conditions in each section. E k
k g
FOR THE NUCLEAR REGULATORY COMMISSION g l F h ,A Date:./Ib,e4 /717R 't i By: Mic1ael F. Weber y Division of Fuel Cycle Safety i:
and Safeguards Washington, DC 20555 ltl
!I -
ti .
I 9003250302 980317 PDR ADOCK O'7001257 I C PDR
...m . -...... ..-. .........- - -...---------
l WOgsdiOiTXJOiniOIO10 tot"JOIOtOIOfDiOIOiOIOIOiOL JOiOiOITE_JOiOiOlasf#JidIJTfffFsifJC]
{NRc FORM 374A
. U.S. NUCLEAR REoVLAToRY CoMMisSloN PAGE 2 or 4 PAGES !
4!
3 . SNM-1227 Amendment 10 %0 d - MATERI ALS LICENSE txxtei or Reference Numter SUPPLEMENTARY SHEET 70-1257
}l 3
d SAFETY CONDITIONS I' l 2
W SAFETY CONDITIONS !Ul Q
h! h
$ \
3! S-1 Authorized use: For use in accordance with the statements, representations, and conditions of Part l l of the licensee's application dated October 28,1996; and supplements dated June 14, August 22, dl 3
and November 11,1996; February 21, March 5, March 12, March 18, April 15, April 24, May 22, June 6, June 9, July 10, July 14, July 15, August 4, August 8, August 13, August 28, September 29, e 5
gl 3
November 14 December 3, and December 30,1997; and January 12, and February 6,1998. jElj A f,l S-2 The licensee shall maintain and execute the response measures in the Emergency Plan, El 3!I 3 Revis!on 21, dated April 28,1997; or as further revised by the licensee consistent with 10 CFR El E
3 70.32(l).
9 I
Notwithstanding Section 6.5 of Part I of tha license dated October 28,1996, new uranium
@l A S-3 gl 3 hexafluoride (UF ) cylinders purchased by SPC shall conform to ANSI N14.1 or to the tinning 3 requirements specified in NRC's Certificate of Compliance No. 9196 for Model UX-30 packages. gll e
g l s S-4 The licensee shall not process alcohol rags through the Modular Extraction / Recovery Facility. hli f* c
- a!
J)l i
!El El 4 n i l 3 !
i 3j M
i
(
I l A I I i
% i !
Yl Y t
% El S i3l t
3 i$!
1 3 itl 9\ l6l a w h h!
Ei !Ell d I
}i l 5 l 8 o M
i I l 3 l l 9 :. t e *
!WI 1g M.Iari C M E M M M M M i=0 m K M M E C K M K M C M M C M M M M l !
'WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWu'
- NRC FORM 374A U.s. NUCLEAR REnULAToRY CoMANssioN PAGE 3 or 4 PaaEs l Ucense Number g i
l.
SNM-1227 Amendment 10 i l
- MATERIALS LICENSE Docket or Reference Number l 1 SUPPLEMENTARY SHEET 70-1257 g I I SAFEGUARDS CONDITIONS i l
l I I
SAFEGUARDS CONDITIONS l
I 1 I
n: *-,1.0 *"% Co,,ue: & A= nung l
I SG-1.1 The licensee shall follow Sections 0.0,1.0, and 6.0 (with all pages designated as Revision 28 and dated June 1996), and Sections 2.0 through 5.0, and 7.0 through 8.0 (with all pages designated as 7 Revision 30 and dated February 1997) of its Fundamental Nuclear Material Control Plan, titled i
" Nuclear Materials Safeguards Procedures Desenption for the Fuels Fabncation Plants, EMF-12(P)." ,
Revisions to this Plan shall be made in agord with, and pursuant to, the provisions of either I
10 CFR 70.32(c) or 70.34. M G I SG-1.2 Notwithstanding Chapter 0.9 Plan identified by Condit Sp-1.1, which commits to l meetmg all Affirmation S%) s contained in NUREG-1065 (Riey>1), I -!
I granted a limited exception from the first Affirmation contained in Gestion 4.3 of NUREG-1065 in
- I that receipt of retumed fuel rods and/or fuel assemblies (that were originally fabricated at the i
licensee's facility andpvhose SNM encapsulation has not been compromised) need not be l i
measured if the ori9inal fabrication values are booked as receipt. values.4 l
SG-1.3 L? M' A special shutdown, cleanout phys {ical m .. .
/Nf n inventory shall be initiated whenever:)
g I
\ T$1 i
C ;[/ r p ,
j (i) a loss / theft indication involving an SNM quantity equal to or greater than the ,
licensee's Detectiori Quantity (as defined in Sectionl8.2.7:of the Plan identified by i I Condition SG-1;1)'cannot otherwise be resolved withm 60 days'of the initiall
' I recognition of such indication,' and **4 ;si 7
C r& d}(({il8Ltl% ,%
I !
(ii) a Regulatory ID (as defined in Section 5:13'of the Plan identified in Condition I l
SG-1.1) equals or exceeds the licensee's Detection Threshold Quantity (as defined in Section 8.2.7 of the Plan identified by Condition SG-1.1).
n .-
L
[
I I
Whenever a special invdrkory is required by either (i) or (ii) above', all unsealed and I
unencapsulated SNM items that are on hand at the time that such a situation is I
determined to exist, shall be measured (even.if previously' measured) for SNM I
i content. '?Y, ,
I SG-1.4 Operations involving special nuclear materials which are not described in the Plan identified in I Condition SG-1.1 shall not be initiated until an appropriate safeguards plan has been approved g I by the appropriate safeguards licensing authonty of the Nuclear Regulatory Commission.
i I I maa*wwi 2.0 - Phwaiemi Pratae*ian For SNM of Low Stre Sionincance I
l I
SG-2,1 The licensee shall follow the physical protection plan entitled "Siemens Power CG'T,oienen Physical l Protection Plan for Special Nuclear Material of Low Strategic Significance," Revision 13, dated I
i I October 1995 (letter deled October 16,1995); and as it may be further revised in accordance with I i
the provisions of 10 CFR 73.32(e).
i I
SG 2.2 The licensee shall onsure that the UO 2Buildin3 is locked when unoccupied l i
I I I I I I I I Iruwwmeeo=eoeooeo,mooooooooouonoTtmaaaWmaaMKmKKKurKM.
I
m m a a m a a m M.KN.X)mr m m_m a a m w w W_.R.mEjpLN gjutW36pugbpLM.N.RNMm_MpLNugtREL idRCfQRM 374A U.s. NUCLEAR RE2ULAToRY CoMMISSloN PAGE 4 OF 4 PAGES g g
g Licenw Number g g SNM-1227 Amendment 10 g l MATERIALS LICENSE twe: or Reference Number g l
SUPPLEMENTARY SHEET 70-1257 g
~
I N g SAFEGUARDS CONDITIONS g i N I N I N I N I N I N l Sechon 3.0 - International Safeauards g 1 N g SG-3.1 The licensee shall follow, as applicable, Codes 2 through 7 of Transitional Facility Attadment g l No.1a dated May 1,1986, to the US/lAEA Safeguards Agreement. g I N g SG-3.2 Notwithstanding the requirements of 10 CFR 7p3 1 j(d) p submit facility data on forms supplied g g by the Commission (including lAFA DIQs)ftheTeen4. ()egy submit required g d g g
- Advanced Nuclear Fuels Corp 6(sttion' license paper
- l l A O N d : -c d W ,). ,;' _.
'/
~
N g q, ;- y- g g t, . '*
, f/;;. p y N -c i % .. N g
'q 1 g
N M
n ." . ::a N
,' ,w N 1 d ,
N 4 <s . .
N N
N N N N N _ N N
N lN N
N N 4 N N N N N N
N.
N N N N N N N N N
N R N W W W W W
N N
N N N N N N N N ,
L m a a m mnanananarn sermonomrurarrrmosomrrimagwwrrn snynu rrnomrdl