ML20203C240

From kanterella
Jump to navigation Jump to search
Amend 8 to License SNM-1227 for Siemens Power Corp
ML20203C240
Person / Time
Site: Framatome ANP Richland
(SNM-1227-A-08, SNM-1227-A-8)
Issue date: 12/09/1997
From: Schwink W
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20203C238 List:
References
NUDOCS 9712150263
Download: ML20203C240 (4)


Text

_a 1

--x 7-

_3sOuuuuuuuuuustwJuOiOiOiFwasOiOuOiOsOuOiOifiOv0iOEFifWWWWK#0iiOuOiggggXiCW_ir gC, FORM 374 U.3 NUCLEAR RE!ULATORY COMMISSION f

g!

M ATERIAl.S LICENSF Q

Igl Pursuant to the Awmic Energy Act of 19$4. as amerided. the Energy ReorFanisation Act l

g{ l ederal llegulatitms. Chapter 1. Parts 30. 31,32. 33,34,35,36,39,40, and 70, and in reliance on statemeets and represmtations heret l

l gl by the hcenwe. a license is hereby inued authorirmg the licenwe m receis c. acquire, ponen. and transfer byprect, source, and special nuclea 1

l material desiFnated below; to uw suct. material for the p 4rpose(s) and at the place (s) designated below; to deber or transfer such material to La Nl persons authorired to receive it in accordance with the regulations of the applicable Par 1(s). This h(enw shall be

$j specihed in Section 18) of the Atomi. Energy Act of 1954. as amended, and is subject to all applicable rules, re Nl Nutlear Regulatory Comminion now or hereafter in effect and to any conditions specined below.

E

$g

I Wl ji-4, Licenwe f

ef1.

Siemens Power Corporation

3. License Number SNM-1227 Amendment 8 W

e i

i d' 2.

2101 Horn Rapids Road M

Richland. WA 99352-0130 9 thritation Date November 30, 2001 I

W g

5. nocte or 70-1257

+

Rcrerence No.

g 6.11) product. Source, arsd/or

7. Chemical and/ot Physical
8. Masimum Amount that Licenwe g

Special Nuclear Matenal Form May Possen at Any one 'nme (4

J Under This License ID iT f

lb

$j A.

Uranium enriched A.

Any A.

350 g U-235 g

in U-235 4

y+,

9 M

B.

Uranium enriched up to B.

Uranium B.

25.000 kg U-235 h

5.00 wt % U-235 compounds g

M C.

Plutonium C.

Sealed sources C.

1mgPuandnotmorel g!

and standards than1.5 millicuries %4 W

M D.

Plutonium D.

Pu0 -00 0,

500 g Pu h

2 2

h stored waste siH g!

gl 9.

Authorized place of use:

The licensee's existing facilities at Richland. Washingtonfj e

e i

10. This license shall be deemed-to contain two sections:

Safety Conditions and W

4 Safeguards Conditions.

These sections are pdrt of the license, and the licensee 9

9 is subject to compliance with all listed conditions in each section, y

T W

k g

I p

l d

FOR THE NllCLEAR REGULATORY COMMISSION V'e l

s m

i M.

n I1!7 7

By: Wglter S. Schwink /d d 4 Date:

_ Division of Fuel Cycle Safety

/v

/>!

and Safeguards f

Washington, DC 20555 f

' M-j i$

w 9712150263 971209 g

Df ADOCK0700g27 g

PDn

%ksmxmwwwwmsxmsw-mmnxamxx2 Pmved m tern nt twyvr a

.EE_MEURUuuRUUULuuuuuLWJWNUNUUUNUILM.m M M N m M.NJEUNC3UNWORUEWEIJ W m m =

FORM T/4A U.S. NUCLE AM REGOLATORY COMMsSSiON PAGE 2

or 4

PAGts g

~

lbenw Numter g

SNM-1227 Amendment 8 a

l SUPPLEMENTARYSHEET MATERIAI,S LICENSE lam Let ce Referenct Numtst l

70-1257 r

AFETY CONDITIONS l

~

LL Ir SAFETY CONDITIONS I

E

'l e

I E

I i

S-1.

Authorized use:

For use in accordance with the statements, representations, and a I

conditions of Part I of the licensee's application dated October 28, 1996: and a

l supplements dated June 14 and November 11. 1996: February 21. March 5. March 7.

t j

March 12. March 18. April 15. April 24. May 1. May 21. May 22. June 6. June 9.

t July 10. July 15. August 4. August 8. August 13. August 28. September 29. and a

November 14, 1997.

r g

S-2 The licensee shall maintain and., nexecute the response measures in the Emergency a

y Plan. Revision 21. dated April 28, 1997: or'as further revised by the licensee g

~

consistent with 10 CFRc70.32(1).

S-3 Notwithstanding,Section 6.5 of Part I of the license dated October 28, 1996. new l uranium hexafluoride (UF ) cylinders purchased by SPC shall conform to ANSI N14.1g g

6 or to the tinning requirements specified in NRC's Certificate of Compliance g

g g

No, 9196 for Model UX-30 packages.

B E

B J

E E

N Gc n

N v.

E g

7 n.

G

's '

g

-i y

k l'

'(

f g

y E

N I

M t

N s

t I

I t

E f

i t

5 R

s 4

kunnrwunsrururucem,ncmormemum,. cur

-= = = m..sacarm--

J

_ m m m u RM RRMJLEUILW_RREJ!LleUELEEREUllLKElll[RRElWLR NR FORM 314A U.S. NUCLEAQ MEGULATORY COMMIS&lON PAGE 3

o 4

PAars a

lxenac Number g

g SNH-1227 Amendment 8 y

3 l

M ATERI Al.S 1,1 CENSE iwei or kefreem Nuroc g

SUPPLEMENTARY SHEET 70-1257 p.

y W EGUARDS CONDITIONS p

I

.9 I

h I

I SAFEGUARDS CONDITIONS I

Section 1.0 - Material Control & Accountina W

W W

d SG-1.1 The licensee shall follow Section; 0.0. 1.0, and 6.0 (with all pages designated 't W

as Revision 28 and dated June 19 %). and Sections 2.0 through 5.0, and 7.0 n

through 8.0 (with all pages designated as Revision 30 and dated February 1997) o e

its fundamental Nuclear Material Control Plan titled " Nuclear Materials

(

Safeguards Procedures Description for thefuels Fabrication Plants. EMF-12(P)."

g Revisions to this Plan shall;be madelin:accordance with, and pursuant to, the a

provisions of either.10 CFR 70.32(c) or 70.34! f y

N' I

SG-1.2 Notwithstanding Chapter 0.0 of the Plan identified by Condition SG 1.1.

n which commits to moeting all Affirmation Statements contained in NUREG-

!g g

1065 (Rev. 1), the licensee is hereby granted a limited exception from

!g the first Affirmation contained in Section 4.3 of NUREG-1065 in that In q!

receipt of returned fuel rods and/or fuel assemblies (that were

!(g originally fabricated at the licensee's facility and whose SNM encapsulation has not been compromised) need not be measured if the l

original fabrication values are booked as receipt values.

ly, j

SG-1.3 A special shutdown, cleanout physical inventory shall be initiated whenever:

4 (1) a loss / theft indication involving an SNM quantity ecual to or greater than the licensee's Detection Quantity (as cefined in

.E Section 8.2.7 of the Plan identified by Condition ~SG-1.1) cannot h

otherwise be resolved within 60 days of the initial recognition of

~

!l#

such indication, and (ii) a Regulatory 10 (as defined in Section 5.13 of the Plan identified in Condition SG-1.1) equals or exceeds:the licensee's Detection l8 Threshold Quantity (as defined in Section 8.2.7 of the Plan lN M.

E M

identified by Condition SG-1;1).

M W

j N

4 Whenever a special inventory is required by either (1) or (ii) above, all R

unsealed and unencapsulated SNM items that are on hand at the time that N

such a situation is determined to exist, shall be measured (even if 8

4 N

previously measured) for SNM content.

E s

E 4

SG-1.4 0)erations involving special nuclear materials which are not described in

{4 E

tie Plan identified in Condition SG-1.1 shall not be initiated until an 1

appropriate safeguards plan has been a) proved by the appropriate W

safeguards licensing authority of the luclear Regulatory Commission.

.N;

'E E

g N

lE' anruna rmrmostrenvmyrsturaracarm n~mourmnscrucermarmrmym_


==_------------w_m,--_---_

yu FOfW M4A U.S.WUoLEAM Mf 0VLATORY COWmSM PAGE 4

0F 4

PAGES, l LkenicNrnder g

SNM-1227 Amendment 8 i

MATERIAL S ! lCENSE tu Let w Heimme Nunder l

SUPPLEMENTARY SHEET 70-1257 g

SAFEGUARDS CONDITIONS s

t I

l l

I l

Section 2.0 - Physical Protection for SNM of Low Strateoic Sionificarce I

e i

SG-2,1 The licensee shall follow the physical protection plan entitled *Siemens Power I

i, Corporation Physical Protection Plan for Special Nuclear Material of Low I

8 j

-Strategic Significance." Revision 13. dated October 1995 (letter dated j

October 16, 1995); and as it may be further revised in accordance with the I

a provisions of 10 CFR 73.32(e).

.n or I

SG 2.2 The licensee shall ensure,thht the 00, Bu{.,1'djng is locked when a

8 unoccupied.

c W

t Section 3.0 - International Safeauards W

SG-3.1 The licensee shall follow, as applicable. Codes 2 through 7 of a

Transitional Facility Attachment No. la dated May 1, 1986, to the US/IAEA e

Safeguards Agreement, e

t N

SG-3.2 Notwithstanding the requirements of 10 CFR 75;11(d) to submit facility a

W data on forms supplied by the commission (including IAEA DI0s), the t

licensee may submit required data in the Advanced Nuclear fuels a

g Corporation license paper format.

t;a 4;

js K

k t

c t

N N

.I Q

R

'3' E

Y l

5 N'

I l

s u'

y I

I I

I E

I I

I I

I I

E I

I L

I E

I ldirrrandnerwrmnerwarmninnvinrrrETenn

'"" " '-~"" -