MONTHYEARML20198N2061986-06-0404 June 1986 Forwards Seismic & Dynamic Qualification Program for Safety-Related Equipment, Per SER Issues 12 & 13.Meeting Requested During Wk of 860707 to Discuss Initial NRC Comments & Finalize Plans for NRC Audit Project stage: Meeting ML20206F2601986-06-16016 June 1986 Notification of 860723 Meeting W/Util in Bethesda,Md to Discuss Technical Issues Re Seismic & Dynamic Qualification Program for safety-related Equipment,Per Confirmatory Issues 12 & 13 in Oct 1985 SER Project stage: Meeting ML20205C3281986-08-0404 August 1986 Forwards Addendum 1 to 2BVM-166, Sqrt & Pump & Valve Operability Review Team (Pvort) Audit Program & Updated Master Equipment List,Per Sqrt/Pvort 860723 Premeeting.List Submitted to Support NRC 860930 Audit Project stage: Meeting ML20212J9281986-08-0404 August 1986 Discusses 860723 Meeting W/Util Held in Response to ,To Discuss Preparation for Sqrt & Pump & Valve Operability Review Team Onsite Review.Onsite Review to Take Place During 860930-1003.Personnel to Attend Listed Project stage: Meeting ML20205D2381986-08-0505 August 1986 Summary of 860723 Meeting W/Util,Westinghouse & S&W in Bethesda,Md Re Preparation for Onsite Sqrt & Pvort Review Project stage: Meeting ML20206T9021986-09-23023 September 1986 Forwards Responses to Sqrt/Pump & Valve Operability Review Team (Pvort) 860723 Meeting Re Pvort Audit & FSAR Project stage: Meeting IR 05000412/19860241986-09-23023 September 1986 Insp Rept 50-412/86-24 on 860902-04.No Violation Noted.Major Areas Inspected:Licensee Activities in Areas of Operations, Maint & QA in Preparation for OL Project stage: Request ML20215N2421986-10-27027 October 1986 Forwards Responses to Sqrt & Pump & Valve Operability Review Team 860930-1003 Audit Issues Project stage: Other ML20204H6291987-03-18018 March 1987 Notification of 870325 Meeting W/Util in Bethesda,Md to Discuss Personnel Issues Uncovered by Sqrt & Pvort,Tracked by SER Confirmatory Issues 12 & 13.Interim Safety Evaluation Encl Project stage: Approval ML19306D7901987-03-18018 March 1987 Notification That 870325 Meeting W/Util in Bethesda,Md to Discuss Personnel Issues Uncovered by Seismic Qualification & Pump & Valve Operability Review Teams Rescheduled for 870401 Project stage: Meeting ML20206G3641987-04-0808 April 1987 Summary of 870401 Meeting W/Util Re Personnel Issues to Be Resolved as Result of Sqrt & Pvort Audits.List of Meeting Attendees Encl Project stage: Meeting ML20215H6161987-04-16016 April 1987 Forwards Responses to Seismic Qualifications Review Team & Pvort Audit Issues Re Seismic & Dynamic Qualification of safety-related Mechanical & Electrical Equipment.One Oversize Drawing Encl Project stage: Other ML20213G4471987-04-29029 April 1987 Forwards Supplemental Info in Response to Pvort SER Specific Issue 3.10.2.3(1) Request by a Masciantonio & C Kiddo During 870427 Telcon W/Et Eilmann,C Hill & B Gooden Project stage: Supplement ML20213G7641987-05-11011 May 1987 Forwards Revised Responses to Sqrt & Pvort Audit Issues, Reflecting Info Requested by NRC at 870430 Meeting & 870501 & 05 Telcons.Info Sufficient to Resolve Remaining Concerns in Confirmatory Issues 12 & 13 Project stage: Meeting ML20214E1711987-05-15015 May 1987 Notifies That Seismic & Dynamic Qualification of safety- Related Equipment Completed,W/Exception of Final Equipment Sys Tests on Three MSIVs Project stage: Other ML20214S8511987-06-0505 June 1987 Forwards Revised Responses to Sqrt Audit Issues,Per 870522 & 27 Requests.Util Considers Supplemental Info Sufficient to Resolve All Remaining Concerns Re Audit Issues Project stage: Supplement 1987-03-18
[Table View] |
Text
_
givg
'A@
M 2NRC-7-124 (412)393-7546 Beaver Valley No. 2 Unit Project Organization Telecopy (412) 393-7889
$Ul$",PA15o77 May 15, 1987 B
Shippingport United States Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
SUBJECT:
Beaver Valley Fower Station Unit No. 2 Docket No. 50-412 Completion of Seismic and Dynamic Qualification of Safety-Related Equipment for BVPS-2 Gentlemen:
This letter is provided to the NRC/NRR staff as a notification that the Seismic and Dynamic Qualification of Safety-Related Equipment for BVPS-2 has 1{
been completed with the exception of final equipment and system tests on the three (3) Main Steam Isolation Valves (MSIV's).
These MSIV's have been completely installed and it is anticipated that the equipment and system tests will be in progress by fuel load (May 21,1987) with completion shortly there-after. Criticality will not occur until testing has been completed.
Appropriate preservice tests that are required for fuel load have either been completed or a 10CFR50.59 safety evaluation is being submitted to the NRC for review.
The above information is being provided to assist the staff in completing the Seismic Equipment Qualification section of the BVPS-2 SER.
Should there be any questions in this regard, please contact Mr. E. T. Eilmann at (412) 393-7895.
DUQUESNE LIGHT COMPANY By E E Carey Senior Vice President TJZ/ijr NR/TJZ/SEIS/DYN AR/NAR cc: Mr. P. Tam, Project Manager Mr. J. Beall, NRC Sr. Resident Inspector Mr. L. Prividy, NRC Resident Inspector Mr. William T. Russell, NRC Region I Administrator INP0 Records Center Y $h$
0 PDR h
.O
7_-.
s United States Nuclear Regulatory Commission Completion of Seismic and Dynamic Qualification of Safety Related Equipment for BVPS-2 Page 2 COMMONWEALTH OF PENNSYLVANIA )
)
SS:
COUNTY OF BEAVER
)
On this /h day of '
M
,/
/
, before me, a Notary Public in and for said Commonwedth and County, personally appeared J.
J. Carey, who being duly sworn, deposed and said that (1) he is Senior Vice President of Duquesne-Light, (2) he is duly authorized to execute and file the foregoing Submittal on behalf of said Company, and (3) the statements set forth in the Submittal are true and correct to the best of his knowledge.
V l1Y$
/'
Notafy Public SMRA 3. FAITOBE, NTAsf rumic SelPMcEPet 30s,SEANES C005ff t!T C08515I185 IIPIMS SCT. 23,1W E ea,Pom::sluenlaknantemaf passe
_