LIMITING CONDITIONS FOR OPERATION SURVEILLANCE REQUIREMENTS Acceptance Criteria for Type B g.

and Type C -rests The combined leakage rate of components subject to Type B and C tests shall be determined under the program established in Appendix J of 10 CFR Part 50 and shall not exceed 0.6 L -

a h.

Main Steam Line Isolation Valves The main steam line isola-tion valves shEll be tested at a pressure of 28 psig for leakage at least once per operating cycle,.

If a total leak rate of 11.5 scf per hour for any one main steam line isolation valve is exceeded, repairs and retest shall be performed to correct this condition.

g l

HATCH - UNIT 1 3.7-6a Proposed TS/0107q/87 0703120310 870304 DR ADOCK 05000321 PDR

r a

Table 3.7-4 (Continued)

Primary Containment Testable Isolation Valves Penetration Number..

Valve Desianstion Notes

. X-18 G11-Fbl9 & F020 (1) (2) (4) (5)'(9)

X-19.

Gil-F003 & F004 (1) (2) (4) (5) (9)

X-20 P41-F049 (1) (2) (4) (5) (9)

X-21 P51-F513 & F514 (1) (2) (4) (5) (9)

X-22 P70-F004, F005 (1) (2) (4) (5) (10)

X-23 P42-F051 (1) (2) (4) (5) (10)

X-24 P42-F052 (1) (2) (4) (5) (10)

X-25 T48-F307, F308, F309, F103 & F324 (1) (2) (4) (5) (9)

X-25 T48-F113 (1) (2) (4) (5) (14)

X-25 T48-F321 (1) (2) (4) (5) (14)

X-25 T48-F104 (1) (2) (4) (5) (14)

X-25 T48-F114, F118A & F322 (1) (2) (4) (5) (10)

X-26 T48-F319 & F320 (1) (2) (4) (5) (9)

X-26 T48-F334A (1) (2) (4) (5) (14) l X-26 T48-F3348 (1) (2) (4) (5) (14)

X-26 T48-F335A & F335B (1) (2) (4) (5) (10) l l

X-26 T48-F340 & F341 (1) (2) (4) (5) (9) l X-26 P33-F002 (1) (2) (4) (5) (10)

'X-26 P33-F010 (1) (2) (4) (5) (14)

X-27A 011-F051 & F053 (1) (2) (4) (5) (10) l X-27F P70-F066 & F067 (1) (2) (4) (5) (10)

HATCH - UNIT 1 3.7-24 Proposed TS/0107q/87

Table 3.7-4 (Continued)

Primary Containment Testable Isolation Valves Penetration Number Valve Desianation Notes X-28F P33-F003 & F011 (1) (2) (4) (5) (9)

X-28A B31-F019 & F020 (1) (2) (4) (5) (9)

X-310 P33-F004 & F012 (1) (2) (4) (5) (9)

X-31F B31-F013A & F017A (1) (2) (4) (5) (10)

X-33C 011-F050 & F052 (1) (2) (4) (5) (10)

X-34E P33-F005 & F013 (1) (2) (4) (5) (9)

X-35A C51-Ball Valve (1) (2) (4) (5) (10)

X-358 C51-Ball Valve (1) (2) (4) (5) (10)

X-35C CSI-Ball Valve (1) (2) (4) (5) (10)

X-350 CSI-Ball Valve (1) (2) (4) (5) (10)

X-35E CSI-Nitrogen Inerting Check Valve (1) (2) (4) (5) (10)

X-39A E11-F016A (1) (2) (4) (5) (9)

X-398 E11-F0168 (1) (2) (4) (5) (9)

X-40C P70-F002 & F003 (1) (2) (4) (5) (9)

X-42 C41-F006 (1) (2) (4) (5) (10)

X-42 C41-F007 (1) (2) (4) (5) (10)

X-44 P41-F050 (1) (2) (4) (5) (9)

X-45F T23-F004 & F005 (1) (2) (4) (5) (9)

X-46 P21-F353 & F420 (1) (2) (4) (5) (9)

X-52B B21-F111 & F112 (1) (2) (4) (5) (10) (11)

X-59A B31-F0138 & F0178 (1) (2) (4) (5) (10)

HATCH - UNIT 1 3.7-25 Proposed TS/0107q/87

Table 3.7-4 (Continued)

Primary Containment Testable Isolation valves Penetration Number-Valve Designation Notes X-205 T48-F310 f. F328A (1) (2) (4) (5) (9)

X-205 T48-F115 & F116 (1) (2) (4) (5) (9)

X-205 T48-F311 & F3288 (1) (2) (4) (5) (9)

X-205 T48-F1188 (1) (2) (4) (5) (10)

X-205 T48-F325 & F327 (1) (2) (4) (5) (9)

X-205 T48-F104 (1) (2) (4) (5) (14)

X-206A E41-F121 & F122 (1) (2) (4) (5) (9)

X-210A E11-F028A (1) (2) (4) (5) (9)

HATCH - UNIT 1 3.7-26 Proposed TS/01074/87

Table 3.7-4 (Continued)

Primary Containment Testable Isolation Valves Penetration Number Valve Desianation Notes X-2108 E11-F0288 (1) (2) (4) (5) (9)

X-2108 E11-F0118 & F026B (1) (2)'(4) (5) (9)

X-212 E51-F001 & F040 (1) (2) (4) (5) (9)

X-213 E51-F002 & F028 (1) (2) (4) (5) (9)

X-214 E41-F021 & F049 (1) (2) (4) (5) (9)

X-215 E41-F022 & F040 (1) (2) (4) (5) (9)

X-217 P33-F007 & F015 (1) (2) (4) (5) (9) 1 i

j HATCH - UNIT 1 3.7-26a Proposed TS/0107q/87

Table 3.7-4 (Continued)

Primary Containment Testable Isolation Valves Penetration Number Valve Designation Notes I

X-220 P33-F006 (1) (2) (4) (5) (14)

X-220 P33-F014 (1) (2) (4) (5) (10)

X-220 T48-F318 & F326 (1) (2) (4) (5) (9)

X-220 T48-F332A (1) (2) (4) (5) (14)

[

X-220 T48-F3328 (1) (2) (4) (5) (14).

X-220 T48-F333A & F3338 (1) (2) (4).(5) (10)

X-220 T48-F338 & F339 (1) (2) (4) (5) (9)

X-221C E51-F104 & F105 (1) (2) (4) (5) (9)

X-222A E41-F111 & F104 (1) (2) (4) (5) (9)

X-223A T48-Air Cylinder (1) (2) (4) (5) (11)

X-223A T48-F342G-L (1) (2) (4) (5) (11)

X-2238 T48-Air Cylinder (1) (2) (4) (5) (11)

X-2238 T489-F342A-F (1) (2) (4) (5) (11) i 4

n l

HATCH - UNIT 1 3.7-26b Proposed TS/0107q/87 4

-=y e i w,

, -...r..,,,,may,c-.w--mww~,..-%,,_.-,-+-,,-+...-,-v--,,,ey,,

._mw.-.m,

-.w~, --,,

.-__,,-,,.,.-.-,.-r~e--4

-