MONTHYEARML20104A2851979-03-0505 March 1979 Containment Leak Rate Test Program Incorporating Updated NRC Positions Project stage: Other ML19282B1571979-03-0505 March 1979 Forwards Reevaluation of Containment Leak Rate Test Program & Proposed Changes to Tech Specs Reflecting Provisions of Updated Program Project stage: Request ML20080J0871984-02-0707 February 1984 Informs That NRC Has Agreed to Issue Changed Pages Re Removal of Ref to Tech Spec 4.7.E Concerning 10CFR50,App J, Per 840127 Telcon Project stage: Other ML18031B3151986-05-14014 May 1986 Informs That Engineering Expertise on Shift Provided by Having Shift Technical Advisor on Duty,In Response to Generic Ltr 86-04.Bachelor Degree in Engineering Discipline Is Min Requirement for Shift Technical Advisor Project stage: Request ML20198B4641986-05-14014 May 1986 Submits Addl Info to Support 771116 Request for Changes to Containment Leak Test Program,Per Rivenbark & Kudrick Requests Project stage: Request ML20215N2381986-10-0707 October 1986 Environ Assessment & Finding of No Significant Impact Re Proposed Exemption from App J Containment Leak Test Requirements Project stage: Approval ML20215N2241986-10-30030 October 1986 Amend 131 to License DPR-57,revising Tech Specs to Delete Ref to Specific Dtd Versions of App J Re Containment Leak Testing Requirements Project stage: Other ML20215N2461986-10-30030 October 1986 Exemption from Certain Requirements of 10CFR50,App J Re Containment Leak Testing Project stage: Approval ML20215N2511986-10-30030 October 1986 Notice of Denial of Application to Amend License DPR-57, Deleting Specific Dtd Version of App J Re Containment Leak Testing Requirements.Hearing May Be Requested Project stage: Other ML20215N2911986-10-30030 October 1986 Safety Evaluation Supporting Exemption from 10CFR50,App J & Amend 131 to License DPR-57 Project stage: Approval ML20212N0121987-03-0404 March 1987 Proposed Tech Specs Deleting App J Leak Rate Testing Requirements for Certain Valves from Table 3.7-4 & Providing Administrative Correction to MSIV Test Pressure Requirement Project stage: Other IR 05000321/19870041987-03-0404 March 1987 Insp Rept 50-321/87-04 & 50-366/87-04 on 870223-27.No Violations Noted.Major Areas Inspected:External Exposure Controls,General Employee Training,Facilities & Equipment & Licensee Program to Maintain Low Exposures Project stage: Request ML20212N0011987-03-0404 March 1987 Application for Amend to License DPR-57,deleting App J Leak Rate Testing Requirements for Certain Valves from Table 3.7-4 & Providing Administrative Correction to MSIV Test Pressure Requirements.Fee Paid Project stage: Request ML20209D0861987-04-21021 April 1987 Revised Application for Amend to License DPR-57,revising Tech Spec Page 3.7-26 to Assign Valve X-211A to Penetration X-210A & Withdrawing Request to Delete Valves E11-F027A & B from Table 3.7-4 Project stage: Request ML20209D1181987-04-21021 April 1987 Proposed Tech Spec Table 3.7-4 Assigning Valve E11-F028A to Penetration X-211A,restoring Valves E11-F027A & B & Deleting Valves E11-F011B & F026B Project stage: Other ML20214T6741987-05-29029 May 1987 Environ Assessment & Finding of No Significant Impact Re Licensee 870304 Application for Amend to Tech Specs,Deleting Certain Valves from Table 3.7-4 That Lists Containment Isolation Valves Subj to Leak Rate Testing,Per 10CFR50 Project stage: Other ML20214T6401987-06-0101 June 1987 Forwards Environ Assessment & Finding of No Significant Impact Re 870304 Application to Amend License DPR-57 by Revising Tech Specs to Delete Certain Valves from Table 3.7-4 Project stage: Other ML20214V6631987-06-0505 June 1987 Environ Assessment & Finding of No Significant Impact Re Amend to License DPR-57,revising Tech Specs to Delete Some Valves from Table 3.7-4 That Lists Containment Isolation Valves Subj to Leak Rate Testing Per 10CFR50,App J Project stage: Other ML20214V6421987-06-0505 June 1987 Safety Evaluation Supporting Amend 140 to License DPR-57 Project stage: Approval ML20214V6531987-06-0505 June 1987 Notice of Issuance of Amend 140 to License DPR-57.Amend Modifies Tech Specs to Delete Certain Valves Listed in Table 3.7-4 as Containment Isolation Valves Requiring Leak Tests & Changing Pressure at Which MSIVs Required to Be Tested Project stage: Approval ML20214V6391987-06-0505 June 1987 Amend 140 to License DPR-57,modifying Tech Spec Table 3.7-4 to Delete Certain Valves Listed as Containment Isolation Valves Requiring Leak Tests & Changing Pressure at Which MSIVs Required to Be Tested Project stage: Other 1986-05-14
[Table View] |
Proposed Tech Spec Table 3.7-4 Assigning Valve E11-F028A to Penetration X-211A,restoring Valves E11-F027A & B & Deleting Valves E11-F011B & F026B| ML20209D118 |
| Person / Time |
|---|
| Site: |
Hatch  |
|---|
| Issue date: |
04/21/1987 |
|---|
| From: |
GEORGIA POWER CO. |
|---|
| To: |
|
|---|
| Shared Package |
|---|
| ML20209D092 |
List: |
|---|
| References |
|---|
| TAC-64785, NUDOCS 8704290180 |
| Download: ML20209D118 (2) |
|
Similar Documents at Hatch |
|---|
|
Text
.-
Table 3.7-4 (Continued)
Primary Containment Testable Isolation Valves Penetration Number Valve Designation Notes X-205 T48-F310 & F328A (1) (2) (4) (5) (g)
X-205 T48-F115 & F116 (1) (2) (4) (5) (9)
X-205 T48-F311 & F3288 (1) (2) (4) (5) (9)
X-205 T48-F1188 (1) (2) (4) (5) (10)
X-205 T48-F325 & F327 (1) (2) (4) (5) (9)
X-250 T48-F104 (1) (2) (4) (5) (14)
X-206A E41-F121 & F122 (1) (2) (4) (5) (9)
X-211A E11-F027A & F028A (1) (2) (4) (5) (9) i s
%$4 DO P
i HATCH - UNIT 1 3.7-26 Proposed TS/01070/87 l
Table 3.7-4 (Continued)
Primary Containment Testable Isolation Valves Penetration 4
Number Valve Designation Notes X-211B Ell-F0278 & E11-F028B (1) (2) (4) (5) (9)
X-212 E51-F001 & F040 (1) (2) (4) (5) (9)
X-213 E51-F002 & F028 (1) (2) (4) (5) (9)
X-214 E41-F021 & F049 (1) (2) (4) (5) (9)
X-215 E41-F022 & F040 (1) (2) (4) (5) (9)
X-217 P33-F007 & F015 (1) (2) (4) (5) (9) 1 i
l
)
HATCH - UNIT 1 3.7-26a Proposed TS/01G7q/87 i
-