UNITED STATES g,

NUCLEAR REGULATORY COMMISSION s

j WASHING TON, D. C. 20555

\\...../

l SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION SUPPORTING AMENDMENT NO.140TO FACILITY OPERATING LICENSE DPR-57 GEORGIA POWER COMPANY OGLETEPT7OWNTORMATION MUNICIPAL ELEGIRIC AUTHORITY OF GEORGIA CITY OF DALTON, GEORGIA EDWIN I. HATCH NUCLEAR PLANT, UNIT-1 DOCKET NO. 50-321 i

l INTRODUCTION l

By letter dated March 4,1987, (Reference 1), and supplemented by letter dated April 21,1987 (Reference 2), the licensee requested a revision to portions of the Hatch Unit 1. Technical Specifications relating to primary containment iso-lation valves. Principally, the licensee's proposal utilizes the findings and reconinendations in a staff SER dated October 30, 1986 (Reference 3). This evaluation assesses the Hatch, Unit 1, updated containment leak rate test pro-gram and its confonnance to the staff SER of October 30, 1986, and to 10 CFR 50, Appendix J.

As discussed in the SER dated October 30, 1986, the staff found the. licensee's updated containment leak rate test program and its associated modifications to the Hatch, Unit 1, Technical Specifications to be acceptable, except for the proposal to delete several Technical Specification tables which listed the con-tainment isolation components. The staff also found acceptable the proposed exemption request for Appendix J regarding the MSIV testing pressure.

EVALUATION The staff has reviewed the licensee's submittal dated March 4, 1987. The.

majority of the proposed changes involve modifications to Technical Speci-fications (TS) Table 3.7-4, " Primary Containment Testable Isolation Valves."

In its submittal, the licensee organized the requested changes into five separate items.

Regarding proposed change Items I and 2 the licensee requested deletion of

-selected containment isolation valves from TS Table 3.7-4.

This table specifies valves that are required to be tested pursuant to Appendix J requirements. The licensee cites the staff's SER dated October 30, 1986 as a basis for the proposed deletions. As discussed in the staff's SER, piping systems that penetrate the torus and terTainate below the water line of the torus do not have to satisfy Appendix J requirements since a supply of water in the torus is assured during pos:

cidat conditions. Consequently, the licensee proposed to delete th: ' f-

d i3clation valves (as listed in its j

8706120213 870605 9

PDR ADOCK 05000321 1

P ppg

March 4, 1987 submittal) from TS Table 3.7-4.

Moreover, the licensee indicated that these selected valves will be tested in accordance with ASME code,Section XI, requirements. Thus, the staff finds the proposed changes are appropriate and consistent with our SER.

Tne licensee's letter of April 21, 1987 (P,eference 2) withdrew the request for the changes originally proposed as change 3 in the letter of March 4, 1987 (Reference 1). Therefore, no change to the Technical Specifications is required for this item.

Regarding proposed changes for item 4, the licensee requested a number of changes to Table 3.7-4.

These changes are editorial in nature and would correct several inaccuracies. Also, these changes do not alter testing requirements. The staff finds the proposed changes do clarify the TS and, therefore, are acceptable.

Lastly, regarding item 5, the licensee requested that a value of 28 psig pressure be inserted into TS Section 4.7.A.2.h, replacing the 1/2 Pa term.

This TS section specifies the test pressure and the leakage criteria for leak testing the MSIVs. The licensee has indicated that 1/2 Pa is equal to 29.5 psig. As discussed in the SER dated October 30, 1986, the staff pro-vided an evaluation allowing the MSIVs to be tested at a reduced pressure (anexemptionto10CFR50,AppendixJ)of28psig,buterroneouslyindicated the value is 1/2 Pa. But the evaluation was based on 28 psig.

In addition, the licensee indicates that Hatch Unit I was originally licensed with a requirement that the MSIVs be tested at a test pressure of 28 osig. Moreover, the licensee notes that the inboard MSIV would begin to lift at a pressure of about 28.5 psig, resulting in a meaningless test.

Even though 28 psig is not equal to 1/2 Pa, the technical assessment as documented by the staff remains unchanged. Therefore, the staff concurs with the licensee's proposal to appropriately insert 28 psig in TS Section 4.7.A.2.h.

ENVIRONMENTAL CONSIDERATIONS Pursusant to 10 CFR 51.32, the Comission has determined that the issuance of this amendment will have no significant impact on the environment (52 FR 21398 ).

CONCLUSION Notice of opportunity for a prior hearing was published in the Federal Register on March 27, 1987 (52 FR 9980). No requests for a hearing were received.

We have concluded, based on the considerations discussed above, that:

(1)there is reasonable assurance that the health and safety of the public will not be en-dangered by operation in the proposed manner, and (2) such activities will be conducted in compliance with the Comission's regulations, and the issuance of the amendments will not be inimical to the comon defense and security or to the health and safety of the public.

U 9-f

. REFERENCES J

1.

Letter from J. P. O'Reilly, Georgia Power Company, to V. S. Nuclear Regulatory Commission, dated March 4,1987.

2.

Letter from L. T. Gucwa, Georgia Power Company, to U. S. Nuclear Regulatory j

Commission, dated April 21, 1987.

3.

Letter from G. W. Rivenbark, NRC, to J. T. Beckham, Jr., Georgia Power Company, dated October 30, 1986.

l Principal Contributors:

A. Notafrancesco L. Crocker Dated: June 5, 1987

.