ML20215N251

From kanterella
Jump to navigation Jump to search

Notice of Denial of Application to Amend License DPR-57, Deleting Specific Dtd Version of App J Re Containment Leak Testing Requirements.Hearing May Be Requested
ML20215N251
Person / Time
Site: Hatch 
Issue date: 10/30/1986
From: Muller D
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20215N226 List:
References
TAC-10710, TAC-64785, NUDOCS 8611050106
Download: ML20215N251 (3)


Text

_ _ _ _ _ _ _ _ _ _ _ _.

4 7590-01 UNITED STATES NUCLEAR REGULATORY COMMISSION GEORGIA POWER COMPANY, ET AL.

DOCKET NO. 50-321 NOTICE OF DENIAL OF AMENDMENT TO FACILITY OPERATING LICENSE AND OPPORTUNITY FOR HEARING The U.S. Nuclear Regulatory Commission (the Commission) has denied in part a request by the licensee for an amendment to Facility Operating License No. OPR-57, issued to the the Georgia Power Company, Oglethorpe Power Corporation, Municipal Electric Authority of Georgia, City of Dalton, Georgia (the licensee), for operation of the Edwin I. Hatch Nuclear Plant, Unit 1 (the facility), located in Appling County, Georgia.

The amendment, as proposed by the licensee, modified the Hatch Unit 1 Technical Specifications, Section 3.7 to delete Tables 3.7-2, 3.7-3 and 3.7-4.

These Tables contain lists of primary containment penetrations and containment isolation valves.

It also deletes the reference to a specific revision of Appendix J.

The licensee's application for the amendment was dated March 5, 1979 and supplemented February 7,1984. Notice of Consideration of Issuance of this amendment was published in the FEDERAL REGISTER on April 25, 1984 (49 FR 17860). All of the requested changes were granted, except the request to delete Tables 3.7-2, 3.7-3 and 3.7-4.

Notice of Issuance of Amendment No.131 will be published in the Connission's Bi-Weekly FEDERAL REGISTER Notice.

The portion of the application which requested deletion of Tables 3.7-2, 3.7-3 and 3.7-4 was denied.

SehinnSt!8)y P

'I g

A The request to delete Tables 3.7-2, 3.7-3 and 3.7-4 was found to be unacceptable because they provide guidance in measuring the compliance of the licensee with the requirements of Appendix J and because deletion would be contrary to current Standard Technical Specifications.

The licensee was notified of the Commission's denial of this request by letter dated By the licensee may demand a hearing with respect to the denial described above and any person whose interest may be affected by this proceeding may file a written petition for leave to intervene.

A request for a hearing or petition for leave to intervene must be filed with the Secretary of the Commission, U.S. Nuclear Regulatory Commission, Washington, D.C.

20555, Attention: Docketing and Service Branch, or may be delivered to the Corcission's Public Document Room,1717 H. Street, N.W.,

Washington, D.C., by the above date.

A copy of any petitions should also be sent to the Office of the General Counsel, U.S. Nuclear Regulatory Commission, Washington, D.C.

20555, and to Bruce W. Churchill, Esquire, Shaw, Pittman, Potts and Trowbridge, 2300 N Street, N.W., Washington, D.C.

20036.

For further details with respect to this action, see (1) the application for amendment dated March 5,1979, as supplemented February 7,1984, and (2) the Commission's letter to Georgia Power Company dated October 30, 1986 which

4 k,, are available for public inspection at the Commission's Public Document Room, 1717 H Street, N.W., Washington, D.C., and at the Appling County Public Library, 301 City Hall Drive, Baxley, Georiga. A copy of Item (2) may be obtained upon request addressed to the U.S. Nuclear Regulatory Commission, Washington, D.C.

20555, Attention: Director, Division of BWR Licensing.

Dated at Bethesda, Maryland, this 30th day of October 1986.

FOR THE NUCLEAR REGULATORY COMMI SION

/w

/d Daniel R. Muller, Director BWR Project Directorate #2 Division of BWR Licensing