ML20207Q731

From kanterella
Jump to navigation Jump to search
Recommends That Board Be Notified of Incident Involving Intentional Damage to Reactor Coolant Pipe.Initially Reported on 830421.Util Encl
ML20207Q731
Person / Time
Site: Diablo Canyon 
Issue date: 04/27/1983
From: Crews J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Eisenhut D
Office of Nuclear Reactor Regulation
Shared Package
ML20204G536 List:
References
FOIA-86-151, FOIA-86-197 NUDOCS 8703050191
Download: ML20207Q731 (1)


Text

,f

'g UNITED STATES

f
  • M *,e.bh. ' i NUCLEAR REGULATORY COMMISSION in c

REGION V g

[

1430 MA"!!A LANE, SUIT E 210

?

g

/

WA LNUT CR E E K, C AltFORNI A 94596

'/

s APR 2 7 199 Docket No. 50-275 50-323 MEMORANDUM FOR:

D. G. Eisenhut, Director, Division of Licensing, NRR FROM:

J. L. Crews, Director, Division of Resident, Reactor Projects and Engineering Programs, RV

SUBJECT:

RECOMMENDATION FOR DIABLO CANYON BOARD NOTIFICATION Region V has been informed of an incident involving damage to a reactor.

coolant pipe at Diablo Canyon Unit 1.

The initial written notification of the incident was provided on April 21, 1983 (Attachment 1).

Subsequently, after concluding that the damage was intentional, the licensee made a verbal report to the NRC on April 22, 1983, in accordance with 10 CFR Part 73.

The-j Region is currently examining the licensee's response to this incident.

The Region recommends this topic be brought to the attention of the Diablo Canyon licensing board.

t

/

8 I

y

/,J. L. Crews, Director f

I Division of Resident, Reactor Projects & Engineering Programs cc:

J. B. Martin, RV T. W. Bishop, RV L. Chandler, ELD

('

s T. Novak, ADL, NRR B. Buckley, LPM, NRR l

H. Schierling, LPM, NRR E. L. Jordan, IE R. F. Burnett, NMSS G. W. Knighton, NRR s

87030$0191 870226 PDR FOIA HOLIEf386-151 PDR_

i II

/

-