EN-97-106:on 971118,notice of Exercise of Enforcement Discretion & NOV & Proposed Imposition of Civil Penalty in Amount of $100,000 Issued to Licensee.Action Based on Two Severity Level III ViolationsML20203A813 |
Person / Time |
---|
Site: |
Perry ![FirstEnergy icon.png](/w/images/a/ad/FirstEnergy_icon.png) |
---|
Issue date: |
11/13/1997 |
---|
From: |
Beverly Clayton, Satorius M NRC OFFICE OF ENFORCEMENT (OE), NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
---|
To: |
|
---|
References |
---|
EA-96-482, EA-96-542, EA-97-047, EA-97-430, EA-97-47, EN-97-106, NUDOCS 9712120214 |
Download: ML20203A813 (2) |
|
Similar Documents at Perry |
---|
Category:ENFORCEMENT ACTION NOTIFICATIONS
MONTHYEARML20209B8891999-05-17017 May 1999 EN-99-019:on 990520,notice of Proposed Imposition of Civil Penalty in Amount of $110,000 Issued to Licensee.Action Based Upon Severity Level II Violation Involving Radiation Protection Manager Discrimination Against Supervisor ML20212H3331998-04-0909 April 1998 EN-97-106A:on 971218,licensee Responded to NOV & Proposed Imposition of Civil Penalty in Amount $100,000.Licensee Denied Violation Re 10CFR50.59 & Requested Remission.Request Denied & Order Imposing Civil Monetary Penalty Issued ML20203A8131997-11-13013 November 1997 EN-97-106:on 971118,notice of Exercise of Enforcement Discretion & NOV & Proposed Imposition of Civil Penalty in Amount of $100,000 Issued to Licensee.Action Based on Two Severity Level III Violations ML20129C5061996-10-0404 October 1996 EN-96-076:on 961009,notice of Proposed Imposition of Civil Penalty in Amount of $160,000 Issued to Licensee.Action Based on Severity Level II Problem Involving Two Violations of 10CFR50.7, Employee Protection ML20057A8071993-08-26026 August 1993 EN-93-083:on 930831,notice of Proposed Imposition of Civil Penalty in Amount of $200,000 Issued to Licensee.Action Based on Licensee Failure to Correct Cleanliness Problems in Suppression Pool & Drywell ML20246M0991989-07-0606 July 1989 EN-89-067:on or About 890711,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $37,000 Will Be Issued Based on Violation Re Failure to Take Proper Corrective Actions in Response to Previous Violations ML20196C4071988-02-0808 February 1988 EN-88-012:on 880211,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $25,000 Will Be Issued to Licensee Based on Failure to Ensure Electrical Equipment Important to Safety Environmentally Qualified 1999-05-17
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARML20212A8531999-09-13013 September 1999 Notice of Violation from Insp on 990712-30.Violation Noted: from 980324-990730,TS SR 3.5.1.4 & 3.5.2.5 Failed to Require Each ECCS Pump to Develop Pump Differential Pressure Greater than or Equal to ECCS Total Flow Resistance IR 05000440/19990131999-09-13013 September 1999 Insp Rept 50-440/99-13 on 990712-30.Violations Noted. Major Areas Inspected:Effectiveness of Pnpp Program for Identification,Resolution & Prevention of Technical Issues & Problems That Could Degrade Quality of Plant Operations IR 05000440/19990091999-09-0909 September 1999 Insp Rept 50-440/99-09 on 990709-0825.One Violation Occurred & Being Treated as Ncv.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20211M6521999-08-31031 August 1999 Revised Page Number 4, P2 Status of EP Facilities,Equipment & Resources IR 05000440/19990121999-08-12012 August 1999 Insp Rept 50-440/99-12 on 990712-16.No Violations Noted. Major Areas Inspected:Emergency Preparedness Program IR 05000440/19990081999-07-22022 July 1999 Insp Rept 50-440/99-08 on 990518-0708.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000440/19990031999-06-10010 June 1999 Insp Rept 50-440/99-03 on 990407-0517.Two Violations Noted & Being Treated as non-cited Violations.Major Areas Inspected: Aspects of Licensee Operations,Maint,Engineering & Plant Support ML20207B1291999-05-20020 May 1999 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $110,000.Violation Noted:Centerior Energy Corp Through Actions of RPM Discriminated Againt Rps,On 970716,as Result of RPS Engaging in Protected Activities ML20209B8891999-05-17017 May 1999 EN-99-019:on 990520,notice of Proposed Imposition of Civil Penalty in Amount of $110,000 Issued to Licensee.Action Based Upon Severity Level II Violation Involving Radiation Protection Manager Discrimination Against Supervisor IR 05000440/19990071999-05-12012 May 1999 Insp Rept 50-440/99-07 on 990412-16.No Violations Noted. Major Areas Inspected:Rp Performance & Oversight of Refueling Outage Activities ML20196A3131999-05-10010 May 1999 Notice of Violation from Investigation on 990129.Violation Noted:On 970114,K Wierman Employed as Training Instructor at Plant & Deliberately Submitted Info to Util That Wierman Knew to Be Incomplete or Inaccurate ML20206Q2301999-05-10010 May 1999 Notice of Violation from Investigation Completed on 990129. Violation Noted:On 970114,info Required by Commission Regulations Not Maintained Complete & Accurate in All Matl Respects IR 05000440/19990061999-05-0606 May 1999 Insp Rept 50-440/99-06 on 990303-04 & 0412-16.No Violations Noted.Major Areas Inspected:Inservice Insp Efforts & Overlay Repairs of N4C Feedwater Nozzle IR 05000440/19990021999-05-0303 May 1999 Insp Rept 50-440/99-02 on 990225-0406.Non-cited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000440/19990051999-04-0202 April 1999 Insp Rept 50-440/99-05 on 990301-05.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Npps ML20204E7901999-03-17017 March 1999 Insp Rept 50-440/99-01 on 990113-0224.Non-cited Violation Identified.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000440/19990041999-03-17017 March 1999 Insp Rept 50-440/99-04 on 990222-26.No Violations Noted. Major Areas Inspected:Radiation Protection Program & Radiological Planning for Upcoming Refueling Outage,Which Included Review of Rwps,Alara Reviews & Dose Goals IR 05000440/19980191998-12-23023 December 1998 Insp Rept 50-440/98-19 on 981021-1202.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering ML20210Q9291998-12-10010 December 1998 Investigation Rept 3-1998-007.No Noncompliance Noted.Major Areas Investigated:Alleged Discrimination Against Radiation Protection Supervisor for Testifying as Witness in Dept of Labor Proceedings IR 05000440/19980221998-11-25025 November 1998 Chemistry & RP Insp Rept 50-440/98-22 on 981102-06.No Violations Noted:Major Areas Inspected:Implementation of Chemistry Program,Meteorological Monitoring Program & Control & Monitoring of Personnel Radiation Dose IR 05000440/19980211998-11-18018 November 1998 Insp Rept 50-440/98-21 on 981019-22.No Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program ML20195C7361998-11-10010 November 1998 Insp Rept 50-440/98-18 on 980909-1020.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20195C7231998-11-10010 November 1998 Notice of Violation from Insp on 980909-1020.Violation Noted:On 980902,inspectors Identified That Fire Watch Did Not Verify That Special Instructions of Burn Permit B98-DG-83,used for Welding Conducted on DG Were Met IR 05000440/19980171998-10-0707 October 1998 Insp Rept 50-440/98-17 on 980831-0914.Violations Noted. Major Areas Inspected:Review of Implementation of Solid Radwaste Mgt & Shipping Program.Insp Also Reviewed Conduct of Radiological Environ Monitoring Program ML20154H1681998-10-0707 October 1998 Notice of Violation from Insp on 980831-0914.Violation Noted:As of 980415,licensee Had Not Made Adequate Surveys to Assure Compliance with 10CFR20.2006 IR 05000440/19980161998-09-25025 September 1998 Insp Rept 50-440/98-16 on 980723-0908.No Violations Noted. Major Areas Inspected:Resident Inspectors Evaluation of Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20151V3521998-09-0808 September 1998 Notice of Violation from Insp on 980727-31.Violation Noted: on 971219,licensee Conducted Breath Analysis as Part of for Cause Test Based on Odor of Alcohol,However Drug Portion of for Cause Test Not Conducted in Timely Manner IR 05000440/19980151998-09-0808 September 1998 Insp Rept 50-440/98-15 on 980727-31.Violations Noted. Major Areas Inspected:Effectiveness of Selected Elements of Security Program IR 05000440/19980131998-08-21021 August 1998 Insp Rept 50-440/98-13 on 980605-0722.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19980141998-08-19019 August 1998 Insp Rept 50-440/98-14 on 980620-24 & 0720-22.No Violations Noted.Major Areas Inspected:Licensee C/A for Issues Identified by NRC Inspections & Licensee Event Repts Submitted to NRC ML20236R8251998-07-16016 July 1998 Insp Rept 50-440/98-11 on 980518-22.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures, Training,Equipment & Supporting Documentation for Maint of medium-voltage & low-voltage Power Circuit Breakers ML20236R8111998-07-16016 July 1998 Notice of Violation from Insp on 980518-22.Violations Noted: as of 980520,as-tested Instantaneous Trip Function of Circuit Breaker EF1B04 Used for Emergency Closed Cooling Pump Motor 1P42C001A,inadequate ML20236N0231998-07-0909 July 1998 Notice of Violation from Insp on 980421-0604.Violation Noted:Inspectors Identified That on 980504,operations Personnel Failed to Verify 1 Restoration Items Specified in Surveillance Instruction Sys Restoration Checklist ML20236N0281998-07-0909 July 1998 Insp Rept 50-440/98-10 on 980421-0604.Violations Noted.Major Areas Inspected:Operations,Maint & Surveillance,Engineering & Plant Support ML20236L8941998-07-0808 July 1998 Errata to Notice of Violation from Insp Rept 50-440/97-21 on 971202-980127.Violation Noted:On 980106,combustible Matl W/No Transient Combustible Permit in Fire Area Containing Redundant Trains of safety-related Equipment,Identified ML20249C5641998-06-25025 June 1998 Notice of Violation from Insp on 980601-05.Violation Noted: on 980504-21,an Individual,Conducting Radiologically Restricted Area Entries Under Radiation Work Permits 980003, 980047 & 980051 Did Not Wear Thermoluminescent Dosimeter IR 05000440/19980121998-06-25025 June 1998 Insp Rept 50-440/98-12 on 980601-05.Violations Noted.Major Areas Inspected:Plant Support ML20217M1311998-04-29029 April 1998 Insp Rept 50-440/98-07 on 980223-0305.Violations Noted. Major Areas Inspected:Operations,Engineering & Maintenance ML20217M1141998-04-29029 April 1998 Notice of Violation from Insp on 980223-0305.Violation Noted:On 980227,licensed Operator Incorrectly Removed Red Tag & Installed Fuse for Annulus Exhaust Gas Treatment Sys Instead of Installing Fuse for ESW Ventilation Sys IR 05000440/19980051998-04-27027 April 1998 Insp Rept 50-440/98-05 on 980209-0408.No Violations Noted. Major Areas Inspected:Portions of Licensee Fire Protection Program ML20212H3331998-04-0909 April 1998 EN-97-106A:on 971218,licensee Responded to NOV & Proposed Imposition of Civil Penalty in Amount $100,000.Licensee Denied Violation Re 10CFR50.59 & Requested Remission.Request Denied & Order Imposing Civil Monetary Penalty Issued IR 05000440/19980011998-04-0707 April 1998 SALP 15 Rept 50-440/98-01 for Plant Covering Period from 960915-980228 IR 05000440/19980061998-04-0101 April 1998 Insp Rept 50-440/98-06 on 980128-0310.Violations Noted.Major Areas Inspected:Licensee Operations,Maint & Engineering IR 05000440/19980031998-03-26026 March 1998 Insp Rept 50-440/98-03 on 980223-27.No Violations Noted. Major Areas Inspected:Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000440/19980021998-03-12012 March 1998 Insp Rept 50-440/98-02 on 980112-16 & 26-30.No Violations Noted.Major Areas Inspected:Operations,Engineering & Review of Effectiveness of CA Program ML20203D8211998-02-20020 February 1998 Notice of Violation from Insp on 971202-980127.Violation Noted:On 971208,an Inspector Observed Fire Door Between Div 2 & 3 Emergency Diesel Generator Rooms Stuck in Fully Open Position ML20203D8241998-02-20020 February 1998 Insp Rept 50-440/97-21 on 971202-980127.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support PNO-III-98-009, on 980123,licensee Declared Unusual Event Under Emergency Plan Because of Spill of Up to 275 Gallons of Refrigerant Called Trichlorethylene.No Plant Personnel Were in Bldg at Time of Spill1998-01-23023 January 1998 PNO-III-98-009:on 980123,licensee Declared Unusual Event Under Emergency Plan Because of Spill of Up to 275 Gallons of Refrigerant Called Trichlorethylene.No Plant Personnel Were in Bldg at Time of Spill IR 05000440/19970171998-01-21021 January 1998 Insp Rept 50-440/97-17 on 971103-07 & 971215-18.No Violations Noted.Major Areas Inspected:Ep Program IR 05000440/19980041998-01-16016 January 1998 Insp Rept 50-440/98-04 on 980105-09.No Violations Noted. Major Areas Inspected:Radiolological,Environ & Chemistry Sections Programs 1999-09-09
[Table view] |
Text
- . . - - - - .--. . _ . .- - - =
Nov;mber 13,1997 EN 97-106 OFFICE OF ENFORCEMENT
, LLQTIFICATION OF SIGNIFICANT ENFORCEMENT ACTION Mqenat:; Centerior Service Company (EAs96-482, 96 542,97-047, 97-430)
Perry Nuclear Power Plant Docket No. 50 440 Eubject: EXERCISE OF ENFORCEMENT DISCRETION AND PROPOSED IMPOSITION OF civil PENALTIES - $100,000 This is to inform the Commission that an Exercise of Enforcement Discretion and Notice of Violation and Proposed imposition of Civil Penalties in the amount of $100,000 will be issued on or about November 18, 1997, to Centerior Service Company, Perry Nuclear Power Plant. The Civil Penalties action is based on two Severity Level 111 violations. The first violation involves an inadvertent reactivity addition that was not prsvented by conective actions for a similar prior event associated with flow control valves for the reactor r& circulating water system. The second violation involves a violation of 10 CFR 50 59 for changes to procedures involving the Emergency Closed Cooling System (component cooling) that resulted in an Unreviewed Safety Question.
In accordance with the Enforcement Policy, a base civil penalty in the amount of $50,000 is considered for a Severity Level lli violation occurring prior to November 12,1996. Because an escalated enforcement action was issued to the Perry Plant within the Itt two years, the NRC considered whether credit was warranted for identification and Corn 9ct/ve Action. For the two violations, credit for Identification was not warranted because the issues were identified by the NRC. Credit for Corrective Action was warranted for the first violation because the licensee held remedial training for the operators involved in the event, provided training to other operators about the event, and modified the system to improve its reliability.
Credit for Corrective Action was alsu warranted for the second violation because the licensee's corrective actions were comprehensive including: current and future refresher training to provide emphasis on the importance of safety reviews and reviewing past safety evaluations to determine if other USQs have not been recognized. This resulted in base civil penalties of $100,000.
A tW Severity Level ill violation was cited for a miswired circuit breaker causing control room emergency venation components to be inoperable on several occasions. A civil penalty was not proposed for this violation becausa credit was warranted for Identification and Conectivo Actions. Lastly, due to the licensee's performance in identifying and correcting an old design issue, Enforcement Discretion was exercised to issue neither a Notice of Violation nor a civil penalty, in accordance with Vll.B.3 of the Enforcemert Policy, for failure to protect necessary cables and equipment from a postulated fire in the control room.
It should be noted that the licensee has not been specifically informed of the enforcement action. The schedule of issuance anti notification is:
Mailing of Notice November 18,1997 Telephone Notification of Licensee November 18,1997 The State of Ohio will be notified.
The licensee has thirty days from the date of the Notice in which to respond. Following NRC evaluation of tha response, the civil penalty may be remitted, mitigated, or imposed by Order.
9712120214 971113 PDR 18E EN-97-106 PDR n PRELIMINARY INFORMATION - NOT FOR PUBLIC DISCLOSURE UNTIL VERIFICATION THAT IIGNWG mc 9ECEIVED ACTION
/)3 g
>gi mm lll ll I.lllli l.li.lL l.l
4- 4 e -4+- 4 --4w . _b 4 A w d-4 :I-4*s 4+_e-,-AA .M.,aM.., me 4M* 9 .+ M A AM.a 4
e 1 EN 97106 Contad ._ Brent Clayton, Region lil, (630) 810-4373.. Mark Satorius, OE, 301-415-2747 Distribution = ,
- OWFN :
OWFN - 'TWFN Regional C4fices
- Chairman Jacksoni EDO OC RI RiV Comm; Dicus -DEDR AEOD Rll __WCFO C::mm. Diaz . DEDO. :
OP CTR - Rlli Comm. McGaffigan- lOE' ~NMSS ,
- SECY- OGC - IRM MA_lk OCA NRR OlG NUDOCS, PUBLIC PA Ol RES 1 IP SP- ~ ACRS J
5 t,
r
- PRELIMINARY lNFORMATION - NOT FOR PUBLIC DISCLOSURE UNTil' VERIFICATION THAT LICENSEE HAS RECEIVED ACTION
_ -..o,_.