Rev 11 to Welding Procedure Spec WPS-11032, Shielded Metal Arc
ML20195F518
Person / Time
Site: Comanche Peak  
Issue date: 09/29/1983
From: Hite J
BROWN & ROOT, INC. (SUBS. OF HALLIBURTON CO.)
To:
Shared Package
ML20195F283 List: ... further results
References
FOIA-85-59 WPS-11032, NUDOCS 8606120162
Download: ML20195F518 (24)


Text

_-

_ = _.. _

l WEL. DING PROCEDURE NO.

nousTow.TuxAS EV56CN 11 Paar 1 op 2

WELDING CODE SUPPORTING POR;S)

  • 0101AB138 Rev.4 ASME 3 & PV SECTION lx WELDING PROCEDURE SPECIFICATION
  • 0101AB212 Rev.3

)

  • 01128B101 Rev.4 I

0112BB112 Rev.0 l

i LP011288301 Rev.0 j

WELDING PROCESS (ES) 1.

Shielded Metal Arc TYPE Manual i

2.

N/A TYPE N/A BASE METALS (QW-403)

POSTWELD HEAT TREATMENT (QW-407)

P No.1** Gr. No.1).Z to P No 1 nr.No.la2 Type N/A l

T'nicknas Rang,.0625" thru 2.00" (1)

IN. Temperature N/A ep Pipe Dia. Rang, Unlimited IN. ' T'ene Range N/A Range for Fillet. Thk (1)

Die Unlimited IN.

)

i

    • A588 Gr. A or B to P1 M70 Gr. D or A120 to Pl-Fillets onlV GAS (QW408)

FILLER METALS (QW404)

Shielding Gas 1.

N/A 4

2. _ _

N/A Pawnt Comp.

N/A F No.1.

N/A CFH (min.)

A No.1.

I 2.

N/A Shidding Gas Flow Rae N/A Flow Rae N/A CFH (min.)

SFA Spec. No.1.

61

2. N/A Pury Gm N/A AWS Class. No.1.

E7018

2. N/ A Trailing Shielding Gm n.

r 2

Size of Electrode 1. 3/32 - 5/32

2. N/ A IN.*

Size of Filter 1.

N/A 2.

N/A IN.

ELECTRICAL CHARACTE RISTICS (QW4001 N/A ht 1.

DCRP 2

N/A Electrode - Flux Class Conau N/A A mps mang, 1. 70 - 195 2

N/A

- M F # t M R R T v A it I e

1. 18 - 27 2~.

N/A EHR N HN..NEdIIIIN. I oc. Sizefrype N/A i

. POSITION (QW406)

TECHNIQUE (QW410)

Welding Position AII Stringer or Weeve Bead 1 Strinoer 2.

N/A Weiding Progression UDWard Seed Width:

See Page 2 Q *fies or Gas Cup Size N/A IN.

1 PREHEAT (QW-406) initial and interpass cleaning: Weiding surfaces shall be wire brushed 60 (2)

,F (Mina a ground a wired a renove slag, scale w ma contaminants.

Prehest Temp.

Interpess Temp. Rang, 60 - 500 (2)(3)(8)F Method of back gouging Air carbon arc and/or Prehest Maint.

N/A

  • F arinder Oscillation 1.

N/A 2.

N/A IN.

JOINT DESIGN (QW402)

Contact Tube to work distanes N/A IN.

Groove Daign Sinole V or U. Flare Bevel Multiple or Single Layw 1.

Mul tiole JointType og Yes Cl N/A BS Ye5 (Pw Side) 2.

N/A Simi1ar to base material Sinole Backing Matt Type Multiple w single Woctrodes i

Trevel Speed (Range) 1. 2.6 A N/A gpy Peening-

..n Not AM66erf oc t e A REMARKS 3519 TCN /

CPSES

  • This PQR includes S lemggajgggtRe its NT L

i c

9308hn o

q l

=

c2 coey 4

=>b L,

23 ASME'Sec

)

831.1 r[

i e

Project:

CPSES 9/29/83 Job No.

CR-0172 d

1 l

Qu W h surance 8606120162 860512 PDR FQIA l

CARDE85-59 PDR_

~ hhsim %wr s WELD NG TECHNIQUE SHEET

  1. ~

P NO.1,(.31 Gnogy 1A2 TopNo. 1 gnopp 1&2 _

~

,"a72

~

THK. R ANGE

.0625" thru 2.00" (1) gy, or 2 yAL.cmT cmou PERurrTes

,f gy,

nooT occu me o s 1/16-3/16 iu' a.s 1/8-1/4

.,y

[.,

/

l, y

0-3/15"

' ' ~

LNN%%N%NWWM y..

l fyyg g Q yh

  • '\\%*N Typical

.f ice g.,-

g CELDING PARAMETERS

'5 INGLE VALUES ARE WINtWUW N-PILLER MET AL GA.s ELECTRICAL DATA y.g,ygg

',j, C[,"t,7o

",,',Tg '

, T,, E G

$5 a

m eLAss mt oc n,

11 SMA or 3/32 E7018 N/A N/A N/A DCRP 70-120 18-27 2.6-7.2 3/8 SMA or 1/8 E7018 N/A N/A N/A DCRP 90-160 18-27 2.6-7.2 1/2 )

SMA or 5/32 E7018 N/A N/A N/A DCRP 110-195 18-27 2.6-7.2 5/8 Maximum thickness of any single depc sited layer shall not exceed 1/2".

PEENING Not Allcwod 60 (2)

., u mAcx couctNcutTNoo Air carbon are: arindina

  • E MEAT TEue.

NTERPAss TEWp.60-500 (2) (3) (8) contact TusE TO WCRK DtST. N/A N/A N/A

.REME AT w AJNT, CRIFICE DA CUP SIZg y

ruNosTEN ELECT.812E & TYPE N/A M ^**

====-

3

" N / A MEbf g WI J f

Ig3gRE 3gRgg y a wem sans u nar!rLgEURE Ulyk l

%tRucTcNs

1. Qualified thickness range:

ASME III

.0625" thru 1.50" - Full penetration buttwelds.

.0625" thru 2.00" - Partial penetration with depth of preparation 3/4" or less All thickness - Fillet welds with maximum throat of 3/4".

ANSI B31.1.0625" thru.750" - Full oenetration buttwelds.

.0625" thru 2.00" - Partial penetration attachments with depth of oreparation i

1/2" or less.

All thickness - Fillet welds with throat thickness 1/2" or less,

2. Preheat Temperatures:

200*F min. - P1 material over 1.250" thickness.

150*F min. - A588 material.

250*F min. - 588 material over 1 1/2" thickness.

175*F min. - For B31.1 when attaching non-pressure parts to pressure parts over 3/4" in thickness.

3. Preheat ar.d interpass temperature (above 150*F) shall be che,cked using temperature indicating crayons or an approved equal.
4. Tack welds shall emplny the parameters for the root pass.
5. Tack welds shall be complete fusion; the starts and stops shall be tapered by grinding so that the initial pass can properly consume the tack.
5. Full penetration welds not utilizing a backing strip shall be back gouged and/or ground to sound metal before welding the second side using the welding parameters shown, i
7. Variation in joint geometrics shown above is permitted provided the specified root opening is maintained.

'l Maximum interpass temperature for concrete embeded base plates shall be 250 F when under 3/4" thickness and 350 F for thickness 3/4" and over.

s.' A588 Gr. A or B or A570 Gr. D or A120 to P1 also qualified. A570 Gr. D and A120 to be welded using only fillet welds.

-... :^ ~.T 1

HOUSTON. TEXAS MD A

11032 l

P. age 1 of 2 WELDING PROCEDURE SPECIFICATION CHANGE NOTICE CURRENT REVISIONS ARE INDICATED BY CHANGE BARS.

REV.

DATE ORIGINATOR OV

  • 1 6-8-77 E. J. Hetko

[

a 2

8-26-77 E. J. Hotko 2 V (/u ifa r ~

3 9-27-78 J. F. Brenicki

// F(hd %

4 12-12-78 J. F. Bronicki F / (62_ LLC _

5 3-30-79 J. F. Bronicki R # dollahn _

6 8-22-79 J. F. Bronicki 12 # #o A M 7

3-20-80

/s/ c. Winwrf ehe T Vbt44h 8

2-23-82 W.E. Baker

/1/A->*--e w le 9

5-19-82 W.E. Baker

/444-*M ' M4f.

g 10 2-23-83 Jimmy Hite WC f4,fful L& REVISION NO.

DESCRIBE THE CHANGE 1

Added PQR 0101BB113 REV.2 to increase minimum thickness range qualified. Added additional joint details.

2 Deleted PQR 0101BB113 and revised minimum thickness qualified.

3 Deleted PQR 0101AB119 and added PQRs 0101AB137, 0101AB138 and 0101AB140 to allow impact velding on Group 2 materials.

Revised preheat requirements. Increased voltage range.

Added joint details.

4 Deleted re.ference to travel speed and double bevel joint detail. Revised voltage range.

5 Retyped on new form. Added the following information:

fillet veld thickness and diameter, electrode - flux classification, preheat maintenance, joint description, trailing shielding gas, tungsten size and type, bead type, initial and interpass cleaning, back gouging method, I

escillation and root spacing. Noted PQR revision and l

deleted PQRs 0101AB137 and 0101AB140 and added PQR 0101AB212, Rev. 1.

Revised amparage and voltage ranges.

6 Noted PQR revisions. Added preheat maintenance, peening, i

root spacing, notes 7, 8 and9 'and layer thickness limitation.

Added joint details. Revised fillet range thicknesses.

J 7

This document has been reviewed for typographical and technical errors and corrected where necessary. The document meets all requirements of the code of record at the date of qualification. Revisions of technical nature listed below are highlighted by change bar(s).

  • REVISIONS MUST BE AMROVED BY THE MANAGER OF MATERIALS ENGINEERING OR H18 DESIGNEE
.- - =

z -

..--- - = -

.r___...

WPS/PQR NO.

HOUSTON, TEXAS 11032 l

Page 2 of 2 WPS/POR. REVISION NO.

DESCRIBE THE CHANGE 8.

Add travel speed. Add partial penetration Flare bevel configuration. Delete preheat maintainence requirement.

Reduced thickness qualified for ASME Section III. Add embeded plate interpass restrictions.

9.

Add PQR 0112BB101 to allow use of additional base metals.

10.

Added PQR 0112BB112 to allow use of ASTM A570 Gr. D material.

Lowered thickness range.

Incorporated ICN's. Revised notes to clarify thickness range and preheat temperature. Add note 9.

11.

Added PQR CP-0112BB301 Rev.0 to allow use of ASTM A120 material.

Added notation that A570 Gr. D. and A120 to be welded using only fillet welds.

l l

  • REVISIONS MUST BE APPROVED BY THE MANAGER OF MATERIALS ENGINEERING OR His DESIGNEE

=

= =

. =

=-- :-. :: =:. l

~

=

HOUSTON, TEXAS 0101A3138 CHANGE NOTICE PROCEDURE OUALIFICATION RECORD OUALIFYING WELDING PROCEDURE SPECIFICATION ESSENTIAL VARIABLES CANNOT BE CHANGED.

CURRENT REVISIONS ARE INDICATED BY CHANGE BARS.

i

[

WPS/POR REV.

DATE ORIGINATOR A/P OV L' l

PQR 1

2-9-79 J. Yen

_ b V._

l

.'.( C~

POR 2

4-3-79 J. Broniekt

_ id. V O _ W._ ws WPS&PQR 3

6-20-79 J. Bronicki f F Qt.fl.(~w venoco 4

3-20-80 C. Wainwricht L.' /# (/%f r.4 ticD WPS/POR. REV151ON NO.

DESCRIBE THE CH ANGE QR 1

Changed " dashes" to "N/A".

Adced WPS number.

PQR 2 -

Retyped on new form. Added the following infor=ation:

VPS number, joint sketch & dimensions, O.D. range qualified, thickness range qualified per process, electrode size, electrode-flux class., consumable insert, velding progression, PWHT type & time range, purge flow rate, bead vidth, orifice or gas cup size.

Changed " passes / side" to " multi or single N

layer", "nu=ber of ares" to "cultiple or single electrode".

Deleted reference to " atmosphere trade name", " backing",

I and "who by virtue of these tests meets velder perfor=ance requirements." Changed coupon diameter fro = 8" (N.P.S.) to

8. 625" (0.D. ).

Changed filler trade na=e to "N/A".

Infor=a-tion previously indicated under " oscillation" is entered under " bead width" and added "N/A" under oscillation.

Changed shielding gas & purge flow rate from 15Cnl ein & SCni min to 15-20 & 5-50.

Corrected SMA travel speed from 2.3-4.8 to 2.1-7.2.

gass o

as WPS 3

Deleted reference to supporting PQR and added peening, preheat maintenance and cup size range.

PQR 3

Changed " thickness range qualified" to " deposited veld metal thickness." Added joint dimension information, tungsten size and type, peening and back gouging.

WPS/PQR 4

This document has been reviewed for typographical and technical errers and corrected where necessary. 2he document meets all requirements of the code of record at the date of qualification. Revisions of technical nature listed below are highlighted by change bar(s).

  • REVislONS MUST BE APPROVED BY THE MANAGER OF MATERIALS ENGINEERING OR His DESIGNEE i

2 m... _.

3

~

b HOUSTON, TEXAS w

~

0101A3138 i

SUPPLEMENTAL TEST RESULT CHANGE NOTICE CURRENT REVISIONS ARE INDICATED BY CHANGE BARS, REV.

DATE ORIGINATOR beP OV L.

1 2-9-79 J. Yen 2I/

2 4-3-79 J. Bronicks jd M QQ 3

6-20-79 J. Bronicki E p. L Q- --

4 3-20-80

&d C. Wainvricht

/- I % tA g2 C _

REVISION NO-DESCRIBE THE CHANGE 1

Noted PQR revi ion.

2 Typed on new form.

3 Added testing laboratory, lab test no. and testing date.

This document has been reviewed for typographical and 4

technical errors and corrected where necessary.

The document meets all requirements of the code of record at the date of qualification.

Revisions of technical nature listed below are highlighted by change bar(s).

l l

l

  • REVISIONS MUST BE APPROVED BY THE MANAGER OF MATERIALS ENGINEERING OR HIS DESIGNEE

_n_-----.

~ ~ _ ~ _ _ _ _ _ _ _. ~

I I

4 HOUSTON.TE X As 0101A3138 4

~

Jaa No.

SUPPLEMENTAL TEST RESULTS TOUCENESS TEST Type: Charpy "V" Fer: ASTM A370 Size: 10m= x 10m=

Specimen Test Notch Identffication Temp Location Energy Ft-Lbs Mils La t. Exp.

Shear 1

0*F Base 82

.054 30 2

0*F Base 59

.037 30 3

0*F Base 98

.064 40 1

0*F Weld 119

.064 40 2

0*F Weld 117

.062 40 3

0*F Weld 47

.032 20 1

0*F HAZ 155

.065 50 2

0*F HAZ 137

.060 70 3

0*F HAZ 121

.070 99 Radiographic Report of Procedure Qualification: Radiography was accomplished in accordance with ASME Section V, Article 2.

The acceptance criteria of ASME Section III, Division I, Subsection NB was saet.

Test conducted by B&R Materials Engineering Lab.

Lab No.78-162 Address: 3100 Cinton Drive, Houston. Texas GeorRe E. Dawson Date

.fulv '41.

197R per We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance with the above listed POR and per requirements of the listed code / standard (s).

S,gned Brown & Root, Inc.

Date

- By N

3

)

!OC.

HOUSTON. TEXAS 0101A3212 CHANGE NOTICE '

PROCEDURE QUALIFICATION RECORD QUALIFYING WELDING PROCEDURE SPECIFICATION ESSENTIAL VARIABLES CANNOT BE CHANGED.

CURRENT REVISIONS ARE INDICATED BY CHANGE BARS.

WPS/POR REV.

DATE ORIGINATOR F0 L*,

POR 1

3-30-79 J. Bronicki ky a

vost,ono

?

6-20-79 J. Bronicki e' F(I f ff dm__

VPS&POR 3

3-20-80

  1. v C. Vainwricht

/Z # UztEfMm 1

mammI 2

C3 E

WPS/POR. REVISION NO.

DESCRIBE THE CHANGE c3 mmme.

PQR 1

Retyped on new form. Added the following information:

[mmmes WPS number, joint sketch & dimensions, 0.D. range qualified, g

thickness range qualified per process, electrode size, electrode-flux class., consumable insert, welding progression.

PWHT type & time range, purge flow rate, orifice or gas cup g

size. Changed " passes / side" to " multi or single layer",

g

" number of arcs" to " multiple or single electrode". Deleted reference to " atmosphere trade name", " backing", and "who by virtue of these tests meets welder perfor=ance requirements".

Changed filler trade name to "N/A".

Corrected purge flow rate from SCFH min to 5-10.

Corrected GTA bead width from 3/8" g

to 5/16" max..

Q WPS 2

Deleted reference to supporting PQR and added peening, preheat Q

maintenance and cup size range.

PQR 2

Changed " thickness range qualified" to " deposited weld metal thickness." Added joint dimension information, tungsten size and type, peening and back gouging.

WPS/PQR 3

This document has been reviewed for typographical and technical errors and corrected where necessary. The document meets all requirements of the code of record at the date of qualification. Revisions of technical nature listed below are highlighted by change bar(s).

  • REVislONS MUST BE APPROVED BY THE MANAGER OF MATERIALS ENGINEERING OR His DESIGNEE l

l

,t

= HoVSTON. TEX AS 1 :;g;f SME SEC. lx Welding Procedure Specification No 0101AB212 Date 9-29-78 3

3-20-80 Revisions WELDING PROCESS (ES) 1.

Cas Tungsten Arc TYPE Manual 2.

Shielded Metal Arc TYPE Manual BASE METALS (OW-403)

POSTWELD HEAT TRE ATMENT (OW-407)

P N o.

I Gr. No.

2 to P No.__1_ Gr. No.

2 Type N/A Thickness Range

.187 thru 2. 00 IN. Temperature N/A op Pepe Dia. Range Unli-ited Time Range N/A l

G AS (OW-408)

FILLE R METALS (OW-404)

Shielding Gas 1.

Arten F No.1 6

2, 4

Percent Comp.

100 A No.1 I

2.

1 Shielding Gas Flow Rate 15 M4n.

CFH SF A Spec No.1.

5.18 2.

5.1 Purge Gas Arcon Flow Rate 5 Mi" _CFH l AWS Class. No.1 E70s-2 2.

E7018 Trailing Shielding Gas Composition N/A Sire of Electrode 1._ N/ A 21/ 37 : 1/ 8. 3 /161N.

Size of Filler 1.

3/32 2.

N/A IN. E LECTRICAL CH AR ACTE RISTICS (OW-409)

" Electrode - Flux Class N/A Current 1.

MEP 2.

MRP Consumable insert Type K. 1/8"x.5 / 32". E705-2 Amps Range 1 100-110 2.70-230 Volts Range 1 10-14 2,

20-28 Tungsten Elec. Size / Type 1/16"-1/ 8"/EWh-lor 2 POSITION (OW-405)

TECHNIQUE (OW-4101 Wolding Position 30 Stringer or Weave Bead 1.

Strincer 2.

Strincer W

Upward Bead Width 1.

I/8 2.

3/4 IN. (Max.)

f elding Progression Orifice or Gas Cup Site 1._.1/4-1/2 2,

N/A IN.

j PQ EHE AT (OW--406)

Initial and interpass cleaning: Welding surfaces shall be wire brushed

' Preheat Temp.

150

  • p (M;n.)

e, ground as required to remove slag. scale or other contaminants.

Inte rpass. Temp. Range 150-500 eF Method of back gouging N/A lPrenest Maint.

150

  • p i

Oscillation 1.

N/A 2.

N/A IN.

5 JOINT DESIGN (OW 402)

Contact Tube to work distance N/A IN.

jGroove Des;gn Si"'le V Multiple or Single Layer 1 Mulciple

! Joint Type OB N/A Cl Yes BS N/A (p,, $; del 2.

Multiple

'Dacking Matt Type N/A Multiple or single electrodes SiDRle Travel Speed (R angel 1.

1-2 2.

2-4 ipM Peening Not Allowed

' Shetch/ Comments FORINFORMATION ONIJ i

. j.

Bevel:

37-1/2*+2-1/2*

Land:

3/32"+0-1/32" k repared oy P

Approved by h_~~

0

  • 2 d/A WELDING ENGINEEMING DATE MATERIALS ENGINEERING OATE
  • 1>-

l ran No.

n e,

~

e 2

HOUSTO N. TE X A3 0101AB212 3

m YC#

WPSNo.

PROCEDURE QUALIFICATION RECORD 0101A3212 3

WELDING PROCESS (ES) 1, Gas Tungsten Arc TYPE Manual 2.

Shielded Metal Arc TYPE Manual B ASE METALS (OW-.403)

JOINTS (OW-402)

Matt. Spec.SA-5 37 ToSA 537 g,,,,,

Type or Grade _ Class 1 Class 1 Angle:

75*

P No. l Gr. No. 2 To P No.

1 Gr No.

2 Land:

_1/16" CouponOD-N/A Thickness 1.00 Plate IN. Root

/

O. D. Range Qualified Unlitr.it e d Opening: N/A Deposited Weld Metal Thk.1.

.125 2,

.875 IN. B. S.

Total Thk. Range Qualified

.187 thru 2.00 IN.

Matt.:

N/A (Joint Design Used)

FILLER METALS (OW--404)

G AS (OW-408)

F. N o.1.

6 2.

4 Shielding Gas Argen A No.1.

1 2.

1 Flow Rate 15 CFH SF A Spec. No.1._

5.18 2,

5.1 Purge Gas Arnon AWS Class. No.1.

E705-2 2,

E7018 Flow Rate 5-10 CFH Size of Electrode 1.Not Recorded 2y32.1/8 Y14n, Size of Filter 1.

3/32 2

N/A IN. ELECTRICAL CHARACTERISTICS (OW-409)

Electrode - Flum Class.

N/A Current 1.

DCSP 2._ DCRP Consumable Insert 1. Tvoe K. 1/8"x5/32.E70S-2 Amps Rangel. 100-120 2.80-225 Trade Name NfA Volts Rangel-17-14 2-71-7R Tungsten Elect. Sere / Type Not Recorded POSITION (OW-405)

TECHNIQUE (OW-410)

Welding Position 30 Stringer or Weave Bead 1.

Strincer 2,

Strincer Weld ng Progression Upward Bead Width 1.

5/16 Max.

2.

3/4 Max.

IN Orifice or Gas Cup Sire 1.

3/8 & 7/16 2.

N/A IN.

PR EHE AT (OW-406)

Osciliation 1.

N/A 2.

N/A IN.

Preheat Temp.

150 eF Multi or Single Layer J.

Multiole Interpass Temp.

150-500 F (Per Sidel 2.

Muleiole POSTWELD HE AT TRE ATMENT (OW--407)

Multiple or Single Electrodes Sincie Type N/A Travel Speed Range 1.

1.'4-1.6 2,2.1-3.7 tpy Temperatu,,

N/A

'p Peening Not Used Time Range N/A Backpou,.:.g method N/A TEN $lLE TEST 5pecirnen Dunensions (IN.)

Ultknete Total Ultknote Unh Charact,r of Fsilure

^** IIN *2I No.

F eg. No.

Wed T4 Th.ch ness Load Lb.

Stres pel And Loc.stion 1 QW-462.1(a) 1.081

.911

.985 81,300 82,538 Weld Metal 2 QW-462.1(a) 1.108

.918 _ 1.017 84,600 83,185 Weld Metal GUIDED BEND TESTS Specirnen S pecirnen No.

F'g. N o.

Type No.

p,g. N o.

Type 1

OW-462.2(a)

SB Satisfactory

_3__ QW-462.2(a)

SB Satisfactory 1

OV-46L2 (a)

SB Satisfactory 4_

OW-46 2. 2 (a)

SB Sa t is f act ory Welder's Name Don 1..

Riza, Martin.Sepchak S.S. No.

450-04-7704, 456-40-9922 Laboratory Test No.78-177 Test Conducted by B&R Materials Engineering Lab.

Address: 3100 Clinton Drive. Houston, Texas per _ George E. Dawson Date ' August 15. 1978 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance with the trouirements of Section IX of the ASME Code.

i ed BROWN & ROOT. INC.

(

~

- * ~~ - --- -~---

  • {*
  • ~ ~ ~

g 2

HOUSTON, TEXAS 0101A3212 SUPPLEMENTAL TEST RESULT CHANGE NOTICE CURRENT REVISIONS ARE INDICATED BY CHANGE BARS.

REV.

DATE ORIGINATOR AM VA

  • 1 3-30-79 J. Bronicki k f 2

6-20-79

. J. Bronicki E K @_C 3

3-20-80

/ju C. Wainwright l'/'(!b fLf y l

REVISION NO.

DESCRIBE THE CHANGE 1

Typed on new form.

2 Added testing laboratory, lab test no. and testing date.

3 This document has been reviewed for typographical and technical errors and corrected where necessary. The document meets all requirements of the code of record at the date of qualification. Revisions of technical nature listed below are highlighted by change bar(s).

FOR INFORMAT10H DM

  • REVISIONS MUST BE APPROVED BY THE MANAGER OF MATERIALS ENGINEERING OR HIS DESIGNEE

.~

==s b HOUSTON TEX 0101Mm Joa h SUPPLEMENTAL TEST RESULTS TOUCENESS TEST Type: Charpy "V" Per: ASTM A370 Size: 10mm x 10mm Specimen Test Notch Identification Temp location Energy Ft-Lbs Mils Lat.Exp.

Shear 1

0*F Weld 177

.071 90 2

0*F Weld 158

.084 90 3

0*F Weld 123

.075 80 1

0*F Base 39

.029 20 2

0*F Base 35

.027 20 3

0*F Base 36

.027 20 1

0*F HAZ 39

.028 20 2

0*F HAZ 45

.031 30 3

0*F HAZ 60

.042 30 Radiographic Report of Procedure Qualification: Radiography was accomplished in accordance with ASME Section V, Article 2.

The acceptance criteria of ASME Section III, Division 1, Subsection NB was met.

Test conducted by B&R Materials Engineering Lab.

Lab No.78-177 Address: 3100 Cinton Drive. Houston. Texas George E. Dawson Date August 15. 1978 p.,

We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance with the above listed POR and per requirements of the listed code / standard (s).

Signed Brown & Root, Inc.

'I O

  • Date By

1 HOUSTON, TEXAS b5

~

Oll2BB101 CHANGE NOTICE PROCEDURE QUALIFICATION RECORD OUALIFYING WELDING PROCEDURE SPECIFICATION ESSENTIAL VARIABLES CANNOT BE CHANGED.

CURRENT REVISIONS ARE INDICATED BY CHANGE BARS.

WPS/POR REV.

DATE ORIGINATOR ROVpL' PQR 1

5-10-77 E. Hotko

[

_jt[ M C, PQR 2

6-8-77 E. Hotko F # (f. f ig m m POR 3

4-3-79 J. Bronicki M () Ldf,gd VPS 6 PQR 4

6-29-79 J. Bronicki W. V (uug h.g.

WPS/POR. REVISION NO.

DESCRIBE THE CHANGE PQR 1

Corrected typographical error on tensile #2 ultimate stress from 74,497 to 71,497.

PQR 2

Corrected travel speed from 10-18 IPM to 2.5-5.5 IPM.

PQR 3

Retyped on new form. Added the following information:

VPS number, joint sketch & dimensions, 0.D. range qualified, thickness range qualified per process, electrode size, electrode-flux class., consumable insert, welding progression, PVHT type & time range, purge flow rate, bead width, orifice or gas cup size. Changed " passes / side" to

"=ulti or single layer", " number of arcs" to " multiple or single electrode". Deleted reference to " atmosphere trade name", " backing", and "who by virtue of these tests meets welr'er performance requirements".

Changed filler trade name to "N/A".

Information previously indicated under " oscillation" is entered under " bead width" and added "N/A" under oscilla tion.

WP::

4 Deleted reference to supporting PQR and added peening and preheat maintenance. Added material specifications to joint detail.

PQR 4

Changed " thickness range qualified" to " deposited weld metal thickness". Added joint dimension information, tungsten size and type, peening and backgouging. Added material specifications to joint detail.

FOR INFORMATION ONLY

  • REVISIONS MUST BE APPROVED BY THE MANAGER OF MATERIALS ENGINEERING OR HIS DESIGNEE

CODE BrownffRoot,Inc.

_.1m,

sege

^s~esec =

0112BB101 Welding Procedure Spe'cification No Date 4/28/77 4

6/29/79 Revisions WELDING PROCESS (ES) 1.

Shielded Metal Arc TYPE Manual 2.

N/A TYPE N/A BASE METALS (OW 403)

POSTWELD HEAT TREATMENT (OW-407)

P N o.

1 Gr. No.

I to P No.

  • G r. N o.

Type N/A Thickness Range

.187 thru 2.00 IN. Temperature N/A

  • F Pipe Dia. Range Unlimited Time Range N/A
  • ASDi A588 Grade B G AS (OW-408)

FILLER METALS (QW-404)

Shielding Gas 1 F No.1.

4 2.

N/A Percent Comp.

b/A N/A A No.1.

I 2.

N/A Shielding Gas Flow Rate CFH SFA Spec. No.1.

5.1 2.

N/A Purge Gas N/A Flow Rate N/A CFH AWS Class. No.1.

E7018 2.

N/A Trailing Shielding Gas Composition N/A S.re of Electrode 1.3/32-5/32 2._

N/A IN.

Size of Filler 1.

N/A 2.

N/A IN. E LECTRICA L CH ARg RISTICS (OW-4091 Electrode - Flux Class N/A Current 1.

2, N/A Consumab'e insert N/A

  1. ~#

Amps Range 1.

2.

N/A Volts Range 1.

18-28 2.

N/A Tungsten Elec. Site / Type N/A POSITIO N (QW-405)

TECHNIQUE (OW-410) 1G Welding Position Stringer or Weave Bead 1.

StrinRer 2.

N/A N/A Welding Progression Bead Width 1.

5/8 2

N/A IN. (Max.)

Orifice or Gas Cup Size 1._N/A 2,

N/A IN.

PR E H E AT (OW-40jl Initial and Interpass cleaning. Wetoing surf aces shall be wire brushed 0

.p g n3 Preheat Temp. _

' 8'*""d '3"id * * * *i'r'bo n A rc a n d / o r 500

'F Interpass. Temp. R ange Method of back gouging Air Ca 70 Preheat Maint.

oF grindine Oscillation 1.

N/A 2.

N/A IN.

JOINT DESIGN (OW-402)

Contact Tube to work distance N/A IN.

Groove Design Double V Multiple or Single Layer 1.

MultiM a Joint Type 08 Yes Cl N/A SS N/A (Per Side) 2.

N/A Backing Matt Type N/A Multiple or single electrodes Sinele Travel Speed (R ange) 1 2-7 2.

N/A IPM 2"

i A588 SA36 in 4

v Bevel:

37 1/2' + 2 1/2* Land: 3/32" + 0 - 1/32" Gap:

1/8" + 0 - 1/32" Prepared oy Approved by

(

6/29/79

[p 6/29/79 WELOI4G ENGINEERING DATT MATERIALS ENGINEERING DATE

---~ ~^

~ ~ '

l Brownf5Rooteinc.

NeUSTeN.T..S

~Lm01 i WPSNo.

PROC'EDURE QUALIFICATION RECORD Oll2BB101 4

WELDING PROCESS (ES) 1.

Shielded Metal Arc TYPE Manual 2.

N/A TYPE N/A BASE METALS tQW-403)

JOINTS (QW-402)

Ma tt. Spec. SA-36 Te ASTM A588 g,,,,,

Type or Grade N/A B

Angle: 75' P No. I Gr. No.

1To P No. N/A GrNo.

N/A Land:

1/16" A588 CouponOD N/A Thickness 1.06 2.O IN. Root SA36

0. D. Range Qualified Unlimited nate Opening: N/A

(

Deposited Weld Metal Thk. I 1.00 2, N/A IN. B. S.

/

Total Thk Range Qualif;ed

.187 thru 2.00 IN.

Matl.:

N/A (Joint Design Used)

FILLER METALS (QW-404)

G AS (OW-408)

F. No. l.

4 2.

N/A Shielding Gas N/A A No.1.

1 2.

N/A Flow Rate N/A CFH SFA Spec. No.1, 5.1 2.

N/A Purge Gas N/A AWS Class. No.l.

F7018 2,

N/A Flow Rate N/A CFH Size of Electrode 1.1/12-5 /12 2,

N/A IN.

Size of Filler 1, M/A 2

N/A IN.

E LECTRICAL CH A R ACTE RISTICS (QW-.409)

Electrode - Flux Class.

N/A Current 1.

DCRP 2,

N/A Consumable Insert 1.

N/A Amps Rangel, 105-190 2.

N/A Trade Name N/A Volts Rangel. 71-?7 2

N/A Tungsten Elect. Size / Type M/A POSITION (OW-405)

TECHNIOUE (OW-410)

Welding Position IC Stringer or Weave Bead 1. Stringer 2.

Stringer Welding Progression N/A Bead Width 1. 5/8 max.

2 N/A IN.

Orifice or Gas Cup Size 1.

N/A 2

N/A IN.

PR EH E AT (QW-406)

Oscillation N/A in.

Preheat Temp.

70

  • F Multi or Single Layer 1 Multiole Interpass Te'mo.70-500
  • F (Per Side) 2.

N/A POSTWELD HEAT TREATMENT (OW-407)

Multiple or Single Electrodes Single Type N/A Travel Speed Range 1. 3-5. 5 2.

N/A lpy Temperature N/A

'F Peening Not used Time Range N/A Backgouging method Coutint and Erindine TENSILE TEST Specimen Demonsions (IN.)

2 Ultimeta Total Ultimate Unit Character of Fa lwre

  • I F eg. No.

Wide Theck ness No.

I Loed Lb.

Stress pil And Location 1

QW-462.1(a)

.990

.956

.9464 67,800 71,639 Base Metal

_2_ QW-462.1(a)

.991

.947

.9385 67.100 71.497 Base Metal GUIDEO B END TESTS Soecimen Specimen No.

F eg. N o.

Type No.

F eg. N o.

Type 1

QW-462.2(a)

SB Sa tis f ac toraf 3

QW-462.2(a)

SB Satisfactory 2

QW-462.2(a)

SB Satisfactory 4

OW-46 2. 2 (a)

SB Satisfactory Welder's Name Don Riza S.S. No.

450-04-7704 Laboratory Test No.

77-96 Test Conducted by B&R Materials Engineering Lab.

Address: 3100 Clinton Drive. Houston, Texas per J.M. Hale cat.

April 28, 1977 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in I

( an fa tu e )

Date By-i i

[

~ _

Brown &RooMnc.

_~.-

Ou2m01 t

SUPPLEMENTAL' TEST RESULTS This Supplemental Test coupon was welded in the 3G, position, progression upward, using the amperage and voltage parac:eters delineated in the original Procedure Qualification Test using a minimum travel speed of 2.6 IPM.

CHARPY "V" NOTCH TESTS (PER ASTM A370)

SPECIMEN SIZE: 10cs x 10=s TEST TEMPERATURE AND MEDIUM: +32 F: drv ice and alcohol THERMOMETER NO.044 SPECIMEN ENERGY LATERAL EXPANSION PERCENT NO.

(FTI"T.B S'. )

(IN MILS)

SHEAR Veld Metal W-1 106 60 70 W-2 103 57 70 W-3 110 58 80

.gJ Base Metal Grade 60 BM-1 44 40 90 BM-2 25.5 42 90 BM-3 60 48 90 O.

Heat Affected seassa Zone-Grade 60 RAZ-1 115 70 90 Eu-2 118 78 90 HAZ-3 121 71 90 Base Metal Grade B 3M-1 135 W

55 80 M"

3M-2 116 55 90

'8"'

62 90 BM-3 145 Heat Affected Zone-Grade B HAZ-1 101.5 W

62 70 RAZ-2 90 56 40 EC-3 35 28 30 82-30 Test conducted by B&R Materiats Engineering Lab.

Lab No.

Address: 3100 Clinton Drive. Houston, Texas Josef Brenicki Date 5-14-82 p,,

We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance with the above listed POR and per requirements of the listed code / standard (s).

Signed Brown & Root, Inc.

'D a t e SY d

1

.m..

CODE Brownf5 Root,Inc.

_.T...,

enks ^ s" ' s ' "

Welding Procedure Soecification No 0112BB112 cat. 12-22-80 Revisions-WE LDINC PROCESS (ES) 1.

SN

____ T Y P E.

W. ii a 2.

N/A TYPE. N/A B ASE METALS (OW-403 POSTWELD HE AT TRE ATMENT (OW 4071 P No.. I Gr. No.

I to P No..A.12.CGr. No. M / A

Typ, N/A Th,ckne,s Raag,

.062

.250 IN.

Tempe r ature N/A og Pipe Dia Range Unlimited Time Range N/A G AS (OW-408)

FIL'.C R ME T ALS (OW 404)

Shielding Gas 1.

M/A F Nc 1.

2.

N/A Percent Comp N/A A No.1 I

2.

N/A Sh, tiding Gas Floa Rate N/A CFM SF A Spec No 1.

5.1 2.

N/A Purge Gas N/A Flow Rate af / a CFH AWS Clan No.1 E7018 2.

N/A Trailing Shield.ng Gas Compootion N/A S.re of E'ectrode 1.

3/32 2.

N/A IN, Sise et ~. lier 1 N/A g,

N/A I N. E LECTRICAL CH AR ACTE RISTICS (OW-409, Elect M: - Flum Class N/A Current 1, DCRP 2

N/A Cc,nsumat.:e insert N/A Amos Range 1 70-120 2.

N/A Volts Range 1.

1R-77 2.

N/A Tungsten Elec. Sire / Type N/A POSIT ONLOW 405)

TECHNIQUE (OW-4101 We'c.ng Ses. tion 1C Stringer or Weave Dead 1 St

  • t*"

2-M/A We:o.ng Prog'ession N/A 8ead Width 1 5/10 2.

N/A IN. (Man.)

Orifice or Gas Cwo Site t N/A 2.

,V / A IN.

P A EME AT LOW-406)

Initial and interpan cleaning: Welding surf aces shall be wire bruine d Pseaset Yer p 70

  • F (Min.1 or ground as required to remove slag scale or ether contaminants, interpass. Te no. Range 70-500
  • p

, Method of back gouging Grind Prenett Ma et 70

  • p Oscillation 1.

N/A 2.

N/A IN.

JOINT DESIGN (CW-402)

Contact Tube to werk distance N/A IN.

Groove Ceogn Scuate Butt Multic't or Single Layer 1. _.bultISI*

Jomt Type Og Yes Ct_

N/A 35' N/A per Side) 2.

U/A Secting P?at. Typ, N/A Multip'e or singte efectrodes SINP19 Trevel Speed (R ange) 1.

3/A

_ 2.

N/A IPM Peening Not Allowed rUK IInUmMTl0N 0Nvi

.. e,c~c.-en t s 6 AbTA ASL m

/

1st

&^ U. s

\\

t v

t 4

  • t l

i Piepared oy Approved by

.f kd c'2l ll

./$ b U

/ ~J/ ~elY _

A'

/

spfg{'0INL, ENGIN'EERING D

M ATERIALS ENME E RING DATE

.w...,

m....

...==-e

...,.s..

...u..

J Brown & Root,Inc.

eu..

.,E...

L~;,n 2 wes No.

PROCEDURE QUALIFICATION RECORD h

0112BF112 0

WELDING PROCESS (ES) 1.

SMAW TYPE Manual 2.

N/A TYPE N/A B ASE ME T ALS (QW-403)

JOINT S (QW-402)

Matt. Spec. SA - 36 ToSA-570 c,,,y, Type or Grad, _ ___ N/ A CR. D Angte:

N/A

'h

,[

P No. I Gr. No.

1 To P No. N/A GrNo.N/A Land:

N/A Coupon OD N/A Thickness

.125 IN. Root O. D. Range Qualified Unlimited Opening: 1/16 Deposited Weld Metal Thk.1.

. 125 2,

Nl i IN. B. S.

Total Thk. Range Owalified

.0625.250

_ IN.

Matl.:

N/A (Joint Design Used)

FILLER METALS (OW--404)

G AS (OW-408)

F No. l.

4 2.

N/A Shield;ng Gas N/A A No.1.

1 2.

N/A Flow Rate N/A CFH SF A Spec. No.1.

5.1 2.

N/A Purge Gas N/A AWS Class. No.l.

E7018 2

N/A Flow Rate N/A CFH Si e of Electrode 1.

3/32 2,

N/A IN.

t Site of Filter 1.

N/A 2,

N/A IN, E LE CTRICAL CH AR ACTE RISTICS (OW-409)

Electroce - Flus Class.

N/A Current 1.

D RP 2.

N/A Consumable insert 1.

M/A Amos Rangel; O

2.

N/A Volts Rangel.

2 2

N/A Trade Name N/A Tungsten Elect. Size / Type N/A POSITION (OW-.405)

TECHNIQUE (OW-410)

IC Stringer or Weave Bead 1. Strinter 2,

N/A Welding Position N/A Bead Width 1.

5/16 2_

N/A IN Welding Progression Orifice or Gas Cup Site 1.

N/A 2

N/A IN.

PR EHE AT (OW-406)

Oscillation 1.

N/A 2,

N/A IN.

Preheat Temp.

70

  • F Multi or Single t.ayer 1.

Multiple interoass Temo 70-500

  • F (Per Sidel 2.

N/A POSTWELD ME AT T RE ATMENT (OW-407)

Multiple or Single Electrodes Single Type N/A Travel Speed Range 1.

N/A 2,

N/A IPM Temperature N/A

'F Peening Not alleved Time Range N/A Backgougir'.g method N/A TENSILE TEST 5poomen Demoneions itN J Uttimeur Total Ulsknete Unis Character of Failuri me UN.2I N o.

F eg. No.

Wecth Thech ne es Load Lb.

Strem pal And Location 1

OV462.1(a) 1.256

.107

.134_

9100 67.910 Duce 11e in Rae, Maen1 l

0W46L i f a) 1_9ac

_7nt

_73g 94c9 69.118 Ductile in Base Metal GulDED S END TESTS soeccen specimen No. l F eg. N o.

Type No.

F ig. N o.

Type A

QW4623(a)

FB Acceptable

_C__ Ou4623(a)

L Acceptable B

QU4623(a)

FB Acceptable

.D_ 0V4623(a) 1]L_

Acceptable Materials Engineering, Power Division Laboratory Test No.

81-2 per J. Justin Berta Date 1/20/81 We cer'tify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance with the requirements of Section IX of the ASME Code.

FOR INFORMATION ONIY c."="-

/

!~

By Date

/

CODE BrownffRoot,Inc. _._

e ls @

as

CP-0112BB301 o,,,7-22-83 iding Procedure Soecification No 0

Revisions Shielded Metal Arc TYPE Manual WELDING PROCESS (ES) 1.

2.

N/A TYPE N/A BASE METALS (QW 403)

POSTWELD HEAT TREATMENT (QW 407)

P No.

I Gr. No.

I to P No.

Gr. N o.

Type N/A N/A op

.0625" thru.674" IN. Temperature Thickness Range N/A Pipe Dia. Range 2 7/8" and over Time Range

  • A120 G AS (QW--4C8)

FILLER METALS (QW 404)

Shielding Gas 1 N/A N/A 4

N/A Percent Comp.

F No.1.

2.

A No.1 I

2.

N/A Shielding Gas Flow Rate N/A CFH SFA Spec. No.1.

5.1 2.

N/A Purge Gas N/A Flow R te N/A CFH O

AWS Cf ass. No.1 E7018 2.

N/A Trailing Shielding Gas Composition Size of Electrode 1 3/32" 2 N/A IN.

Size of Filter 1.

N/A 2.

N/A IN. ELECTRICAL CH AR ACTE RISTICS (QW-409)

Electrode - Flux Class N/A Current 1 OCRP 2.

N/A N/A Amos Range 1 70-120 2.

N/A Consumable insert 19*27 2.

N/A Volts Range 1.

N/A Tungsten Elec. Size / Type

'OSITION (CW-405)

TECHNIQUE (QW-410) 26 Both N/A elding Position Stringer or Weave Beed 1 2.

Welding Progression Bead Width 1.

3/8" max.

2.

N/A IN. (Max.)

N/A Orifice or Gas Cuo Siza 1 N/A

2. N/A is, FREHEAT (QW 406)

Initial and interpass cleaning: Welding surf aces shall be wire brushec Prehest Temp.

60

  • F (Min-)

or grouna as required to remo ag, scale or other contaminants.

Inter ass. Temp. Range 60-500

  • F Method of bar.k gouging Preheat Maint.

N/A

  • F Oscillation 1.

N/A 2.

N/A IN.

JOINT DESIGN (QW 402)

Contact Tube to work distanca N/A IN.

l Mul tiole Greeve Design U"O

  • V Multiple or Single Layer 1.

Jcint Type CB N/A Cl N/A BS Va5 (Per Sidel 2.

N/A Cacking Mad Type Similar to base material Multiple or single electrodes Sinale Travel Sceed (R angel 1 2.6 - 7.2 2.

N/A ipy Peening Not Allowed Sketch / Comments FOR INFORMATION ONLY l

Precared oy Approved by 9 D 3-9 5

//

/ f/

h--ff="fh 5 %*ul mE P w ect ve wind Engineer o.TE c: 6 G @ N EE h G

HOUSTO N. TEX As

-0112BB301 0

0!'

PROCEDURE QUALIFICATION RECORD

~

esNo.

CP-0112BB301 WELDING PROCESS (ES) 1 Shielded Metal Arc TYPE Manual NA 2-NA TYPE BASE METALS (QW-403)

JOINTS (QW--402)

Mati. Spec. SA-106 To SA-.

A120 a,,,,,

Type or Grade B

NA Angfe:

75' P No.

I Gr.No.

1 To P No. NA a, ua, Land:

1/16" 7

T NA CouponOD 4.50" Thickness

.337" IN. Root r

O. D. Range Qualified 2-7/8" and over Opening:

3/16" y

Deposited Weld Metal Thk.1.

33 7 2.

NA IN. B. S.

Total Thk. Range Qualified

.0625" thru.674" IN.

Mat!.:

A109 Uoint Design used)

I FILLER METALS (CW-.404)

GAS (QW-408)

F. No.1.

4 2.

NA Shielding Gas NA f

A No.1.

1 2.

NA Flow Rate NA CFH NA SF A Spec. No.1 L1 2-NA Purge Gas AWS Class. No.1.

F701R 2-NA Flow Rate NA cpy Size of Electrode 1. 3 /3?"

2 NA IN.

Size of Filter 1.

NA 2_

NA IN. ELECTRICAL CHARACTERISTICS (QW-4091.

Electrode - Flux Class. NA Current 1, DCRP 2,

NA Consumable Insert 1.

NA Amps Range 1 78 - 92 2.

NA Volts Rangel-77 7a 7

4A Name NA Tungsten Elect. Size / Type NA POSITION (QW-405)

TECHNIQUE (QW-410)

Welding Position 2G Stringer or Weeve Bend 1 Stringer 2,

NA Welding Progression NA Bead Width 1.

3/8" 9

NA IN.

Orifice or Gas Cup Size 1.

NA

2. NA IN.

PR EHEAT (QW-406)

Oscittation 1.

NA 2,

NA IN.

Preheat Temp.

90

  • F Multi or Single Layer 1 Multiole NA Interoass Temo. 80 - 275
  • F (Per Side) 2.

POSTWELD HEAT TREATMENT (QW-407)

Multiple or Single Electrodes Single Type NA Travel Speed Range 1.

34" - 7" 2, NA ipy Temperature NA

'F Peening Not Allowed Time Range NA Backgouging method NA TENSILE TEST Specimen l

Dimesions (IN.)

Ultimais Total Ultknste Unit Character of Fanure No.

Fig. No.

Wid1n Thickness Lond Lb.

Stress pel And location 1

OW.462.1(b)

.743

.259

.1924 11980 62,266 Base Metal 2

QW 462.1(b),.739

.245

.1811 11860 65,488 Base Metal GulOEO BEND TESTS R easit Remsit No.

Fig. N o.

Type No.

Fig. N o.

l Type 1

OW 467 3 M F

Sa tis factory 1

QW 462.3 (a)

R Satisfactory l

2 QW 462.3 (a)

F Satis factory 2

QW 462.3 (a)

R Satisfactory Welder's Name Fred Nichols S.S. No.

463-74-9587 Laboratory Test No. CP-014 Test Condue:ed by B&R Materials Engineering Lab.

Address: 3100 C!inton Drive, Houston, Texas per Jimmy Hite Date We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in (Man ure )

9-13-83

//

A*/

Date By

WELD PROCEDURE SPECIFICATION - INTERIM CHANGE NOTICE LATEST ICN No.

I to WPS 11032 Rev. 11 The following Interin Change Notice is being submitted at this cine in order to expedite the revision of a non-essential variable in a Brown & Root, Inc.

Weld Procedure Specification.

ICN No.

1 Changes / Additions:

4/13/84 Date o/6,/

f/22/3.

On page 2 of 2 add the following to Note 1 under the ANSI B31.1 thickness range:

.0625" thru 1.50" - Structural welds (Does not M/

/.

include pressure parts or attachments to pressure p'

parts).

A, ~

PQAM v

c l t < [ %

< !. 6 and/or P NSSS DM ICN No.

Changes / Additions:

Date PWE PQAM PDM and/or P NSSS DM ICN No.

Changes / Additions:

Date FORINFORMATION ONLY PQAM PDM and/or P NSSS DM ICN No.

Changes / Additions:

Date Ph?

PQAM PDM and/or P NSSS DM wr-wy

Brownf'7' Root,Inc. east office sox 100,. oien nose. Texas 7eo43

~

miiaam BRF #11281 September 27, 1983 Mr. J.T. Merritt, Jr.

Texas Utilities Services, Inc.

P.O. Box 1002 Glen Rose, Texas 76043 Texas Utilities Services, Inc.

Comanche Peak Steam Electric Station Approval of Welding Procedure Specification

Dear Mr. Merritt:

)

1 Attached is a copy of Welding Procedure Specificatio i WPS 11032, Rev.11 for review and approval by Texas Utilities Services, Inc.

This Welding Procedure Specification is to be used in conjunction with the following Brown & Root Specifications:

CP-CPM 6.9 WES-031 Please review / approve subject procedure at your earliest convenience.

Very truly yours, BROWN & ROOT, INC.

h%W 1

m

/ D.C. Frankum Project Manager DCF/ WEB /JN/ tin APPROVED:

Attachment cc:

J.T. Merritt

'i m th TAN =Mkr e f4lg3 T. Merritt, Jr.

Date ngr. & Const. Mgr.

. _.,.