PRAIRIE ISLAND SITE NORTHERN STATE 3 POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION TITLE:

NUMBER:

4

]

,f~ M [

DESIGN CHANGE DESCRIPTION /

5AWI 6.1.4 i

SAFETY ASSESSMENT REV:

g i -

Prepared By Effective Date:

lo -IF-%

b4 M7&< N #

Ouality Review By:

Approved By:

4 PLANT M GER 1.0 PURPOSE This Instruction establishes the method for preparing Project Description / Safety Assessment (PD/SA), for design changes and the coordination with 5AWI 3.3.2, Safety Evaluation.

2.0 C_OJ_ TENTS Section Title Page 6.1 General Requirements & Recommendations.................................

3 3

6.2 Project Description Content..................

4 4

6.3 Review and Approval 7

(*

6.4 R evisio n s..............................................................

7 I (

6.5 Required Records.....................................................,

8 List of Figures FIGURE 1 - PROJECT DESCRIPTION / SAFETY ASSESSMENT, PINGP 1214.................

9 List of Tables TABLE 1 - SOU RCE DOCUM ENT INDEX............................................

12

^

TABLE 2 - SIGNIFICANT CHANGES FROM THE PREVIOUS REV'JION...................

13 3.0 APPLICABILITY This Instruction SHALL apply to all design changes.

O U

9809220176 980915 PDR ADOCK 05000282 Page 1 of 13 p

PDR

w i

PRAIRIE ISLAND SITE NORTHERN STATES POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION NUMBER:

TITLE:

g 5AWI 6.1.4

5AWIL DESIGN CHANGE DESCRIPTION /

SAFETY ASSESSMENT REV:

0 4.0 DEFINITIONS

' NOTE (* -

Defin ti ns may als be found under Pl Documents on the Site Information System.

UNREVIEWED SAFETY QUESTION As defined in 10CFR50 and 10CFR72 applies to changes, tests or experiments.

10CFR50.59 (a) (2) and 10CFR72.48 (a) (2) state:

"A proposed change, test, or experiment SHALL be deemed to involve an unreviewed safety question (i) if the probability of occurrence or the consequences of an accident or malfunction of equipment important to safety previously evaluated in the safety analysis report may be increased; or (ii) if a possibility for an accident or malfunction of a different type than any evaluated previously in the safety analysis report may be created; or (iii) if the margin of safety as defined in the basis for any technical specification is reduced."

5.0 RESPONSIBILITIES 5.1 The General Superintendent Engineering (plant & NGS) SHALL be responsible for assuring safety evaluations are completed when necessary.

5.2 The Preparer of the Project Description / Safety Assessment (PD/SA) SHALL be responsible for preparing the PD/SA in accordance with this instruction and SAWI 3.3.2, Safety Evaluations.

5.3 The Reviewer of the PD/SA SHALL be responsible for ensuring the technical adequacy of the PD/SA and its conformance to the requirements of this instruction.

5.4 The Operations Committee SHALL be responsible for reviewing the PD/SA for impact on plant safety.

5.5 The Design Engineering Coordinator (DEC) SHALL maintain an index and computer data base of completed PD/SAs.

O Page 2 of 13

__7

? r PRAIRIE ISLAND SITE NORTHERN STATES POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION TITLE:

NUMBER:

O 5AWi[

DESIGN CHANGE DESCRIPTION /

5AWI 6.1.4 SAFETY ASSESSMENT REv:

o m

l 6.0 REQUIREMENTS AND RECOAIMENDATIONS l

6.1 General Requirements & Rocommendations 6.1.1 This AWI contains requirements for preparation and content of Project Descriptions and Safety Assessments and their use in proposed plant design changes.

6.1.2 5AWI 3.3.2, Safety Evaluation SHALL be used when it is determined to be necessary in the Project Description / Safety Assessment.

6.1.3 The Project Description SHALL include justification if the design change is performed to less than original specifications or design bases.

6.1.4 A Project Description SHALL comprise / coordinate design criteria as design input i

for projects. Large scale projects may accumulate numerous additional inputs as detailed design proceeds. The Project Engineer determines the manner of tracking design inputs not indicated in the Project Description,5AWI 6.1.1, Design input.

6.1.5 If a Preliminary Project Description is desired by management, it should follow the same format as the Project Description to clearly define the plant's needs and technical requirements for the project.

a. When the Preliminary Project Description is prepared, the Project Engineer should:

1.

Obtain concurrence from the Solution Team that the Preliminary Project Description is ready for initial review.

2.

Distribute copies of the unsigned Preilminary Project Description to the Solution Team members,

b. The preliminary Project Description may be revised as necessary to adequately describe project development during the planning phase of the design change. The Preliminary Project Description should be transformed into the final Project Description for inclusion in the Design Change Package.

6.1.6. The Project Engineer should resolve or incorporate comments of the Solution Team into the project's PD/SA.

f je 3 of 13

4 PRAIRIE ISLAND SITE NORTHERN STATES POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION TITLE:

NUMBER:

J g

5AWI 6.1.4 L5 awl; DESIGN CHANGE DESCRIPTION /

SAFETY ASSESSMENT REV: g G.2 Prolect Description content 6.2.1 The preparer SHALL use PINGP 1214 or equivalent to compile the Project Description / Safety Assessment.

6.2.2 The preparer SHALL transfer the electronic file via E-mail to the DEC for i

electronic storage of completed / reviewed PD/SA.

6.2.3 The PD/SA of the first part of a multiple part design change SHALL contain a brief description of each of the parts.

6.2.4 The Project Description SHALL include the following to the extent that they are applicable to the plant design change or part of a plant design change covered by the description:

a.

Title Page l

Use the same title as the IPC approved title, indicate the design change number and the proper part and revision number.

h

b. Jntroduction A summary of the scope, purpose and design objectives for the entire integrated project. Indicate quality classifications such as safety related, fire protection related, or security related. If only portions of a project require special quality requirements, then specifically state the boundaries of the OA classifications.

l c.

Summarv Summarize the significant points of description and Safety Assessment that establish the Safety Assessment conclusion. The summary is written such that the test may be used for completing the USAR/ISFSI SAR change input.

See SAWI 6.1.7, Design Change Review & Approval d.

Scope A detailed and concise definition of the specific work scope covered by the i

design change. Consider mechanical, civil, structural, nuclear, electrical, operational and I&C attributes in the description. This is particularly important when a plant design change is performed in parts. Define the g

i scope of the project by specifying impacted structures, systems, or components.

Pcge 4 of 13

i PRAIRIE IILAND SITE NORTHERN STATES POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION TITLE:

NUMBER:

' O

>15AWil DESIGN CHANGE DESCRIPTION /

5AWI 6.1.4 SAFETY ASSESSMENT Rev:

O e.

Descriotion A description of the plant design change provides sufficient detail to enable staff and a review committees (some of which do not have detailed knowledge of the plant) to understand what structures, systems and components are to be added or modified. The description includes or refers to electrical schematics, logic diagrams, P&lDs, one-line diagrams, general structural layout drawings, sketches, etc., as needed. Also, discuss the design basis possible failure modes considered for the design change, accident review. Refer to SAWI 3.3.2, Safety Evaluations, if a Safety Assessment is required. Consider mechenical, civil, structural, nuclear, electrical, operational and l&C attributes in the description.

1.

Provide important functional design parameters, such as pressures, flows, temperatures, trip setpoints, alarm settings, etc.

2.

Describe design features, operating functions, and interlocks. The reader should be able to understand how the design performs its

(]_

function.

3.

Specify the plant operating problems or needs that are to be addressed, and the regulatory requirements or commitments that are to be satisfied by the project.

f. Oraanizations involves Description of the groups and organizations associated with the plant design change and their scope of involvement. This includes specifying design by consultants, contractors, or other outside design organizations.

1.

For plant design changes subdivided into several parts and assigned to different organizations, preparation of documented division of responsibilities is considered.

2.

The Project Engineer SHALL notify other organizations that are required to approve, or be notified of the plant design change. This notification should include organizations to which commitments impacted by the design change have been made or are affected. This notification should consist of:

[]

a) A description of the design change being made.

Page 5 of 13

o PRAIRIE ISLAND SITE NORTHERN STATES POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION TITLE:

NUMBER:

g 5AWI 6.1.4 5AWt DESIGN CHANGE DESCRIPTION /

SAFETY ASSESSMENT REV:

0 b) A description of the commitment, how the commitment is satisfied, or justification for retracting or altering the commitment The submittal of the letter wouici be through normal NSP

. NOTE:

communications channels with the given agency, and may require agency approval.

g.

Engineerina Considerations & Desian Inouts.

A description of engineering considerations with principal benefits is included. Information comprising design inputs is defined here until otherwise dispositioned by the Project Engineer for design control of complex design changes.

1.

Specify the technical requirements of the project and special considerations that are to be addressed in the project. The Design Change input Applicability checklist (PINGP 1213) SHALL be utilized to identify engineering considerations.

2.

If a Safety Assessment is required, the following 5AWI 3.3.2 content information is also required.

a) A discussion of the effects of the design change.

b) A statement concerning changes to Technical Specs.

3.

Identify how operational holds will be applied in order to ensure adequate holds are placed on the plant to prevent the plant from being placed in a condition requiring the system or component being modified to be operable prior to the modified system or component being turned over for operations. Refer to 5AWI 6.1.5, Design Change implementation Plan, for operational hold codes.

h.

Materials. Codes & S_landards 1.

Specify the codes and standards to be utilized with appropriate edition / addenda, revisions, or date. These SHALL include codes and standards such as ASME, IEEE, ANSI, AWI, AISC, or NFPA. It is not intended that manufacturing or product standards such as NEMA, UL, or ASTM be included. However, regulatory documents such as 10CFR, g

49CFR, NRC Reg Guides, NSP Commitments, NUREGs, and NRC Correspondences should be quoted or referenced as applicable.

Page 6 of 13

l PRAIRIE ISLAND SITE l

NORTHERN STATES POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION TITLE:

NUMBER:

7 O

isAwrL oeSian osanaE oeScaieTion/

5^*i a ' 4 SAFETY ASSESSMENT REv:

0 2.

Discuss the most important specification; i.e., codes, standards, l-materials, components, specifications, etc.

i. Construction / Plant Interface Considerations Discuss potential impacts that construction may have upon the plant from an operations and safety viewpoint. Define construction commitments which will eliminate or mitigate these impacts.

J. Testing i

Specify known construction, pre-operational and operational testing requirements and reason for testing. Specify long term testing required for operational or Technical Specification surveillances, if known.

k.

Safety Assessment Discuss potentialimpacts of this project on nuclear safety as described in (3) the USAR/ISFSI SAR, Tech Specs and Design Basis documentation.

6.3 Review and Approval 6.3.1 The originator signs and dates the Project Description / Safety Assessment.

6.3.2 Project Descriptions / Safety Assessments are reviewed for accuracy by an individual other than the preparer who is knowledgeable of the design change.

Project Descriptions SHALL be signed and dated by the reviewer. This review is not required to serve as design verification (elective) since design verification is normally done on individual design documents in preparation of detailed design output for construction.

6.4 Revisions 6.4.1 Changes to items previously reviewed / approved by the Operations Committee may be approved by the Gen Supt. Engineering (plant) if there is no change in acope or intent.

i 6.4.2 If the revision does change the scope and intent, the entire design change package SHALL be reviewed under the same review criteria as the original.

i v

Page 7 of 13

.. ~.

o PRAIRIE ISLAND SITE NORTHERN STATES POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION TITLE:

NUMBER:

g 5AWI 6.1.4 5 awl; DESIGN CHANGE DESCRIPTION /

SAFETY ASSESSMENT REV:

0 6.5 Required Records The following Records Management System records SHALL be collected, stored and maintained per 5AWI 3.4.0 for the period indicated.

Project Description / Safety Assessment ufe of Plant l

l l

i O

l l

l I

l O

Page 8 of 13

i PRAIRIE ISLAND SITE NORTHERN STATES POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION TITLE:

NUMBER:

O 25AWij DESIGN CHANGE DESCRIPTION /

5AWI 6.1.4 SAFETY ASSESSMENT REv:

o FIGURE 1 - PROJECT DESCRIPTION / SAFETY ASSESSMENT, PINGP 1214 EXAMPLE ONLY USE CURRENT REVISION PINCP 1214, Rev. 0 2;;:WE Design Change #

Pad of Rev.

Title:

Unit i

PROJECT DESCRIPTION / SAFETY ASSESSMENT 5AWI 6.1.4 l

Prepared by:

Date:

i Reviewed by-Date:

O Page 1 of 3 Page 9 of 13

t PRAIRIE ISLAND SITE NORTHERN STATES POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION NUMBER:

TITLE:

g 15AWil DESIGN CHANGE DESCRIPTION /

5 AWI 6.1.4 SAFETY ASSESSMENT REV:

0 FIGURE 1 - PROJECT DESCRIPTION / SAFETY ASSESSMENT, PINGP 1214 [ CONT'D]

EXAMPLE ONLY USE CURRENT REVISION O N e$ao Resanoen: Ofe of PhWd Design Change #

Pad of Rev.

Title:

Unit 1.

INTRODUCTION 2.

SCOPE 3.

DETAILED DESCRIPTION 3.1 General 3.2 System Details 3.3 Operator Interface 4.

ORGANIZATION INVOLVED (Address Training) 5.

ENGINEERING CONSIDERATION 5.1 Mechanical Design Piping Structural 5.2 Electrical and l&C Power instrumentation 5.3 Computer Hardware / Software Design 5.4 Human Factors 5.5 Construction and Testing Electrical / l&C Mechanical 6.

MATERIAL, CODES AND STANDARDS 7.

CONSTRUCTION / PLANT INTERFACE CONSIDERATIONS l

7,1 Plant Conditions 7.2 Special Construction Considerations Mechanical Electrical Page 2 of 3 i

Page 10 of 13

~.

! s PRAIRIE ISLAND SITE NORTHERN STATES POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION TITLE:

NUMBER:

lO J5AWii DESIGN CHANGE DESCRIPTION /

5AWI 6.1.4 f

SAFETY ASSESSMENT REv:

o FIGURE 1.- PROJECT DESCRIPTION / SAFETY ASSESSMENT, PINGP 1214 [ CONT'D]

EXAMPLE ONLY I

l USE CURRENT REVISION PINOP 1214, Rev. O l

NI"n.YM Design Change #

l Part of Rev.

Title:

Unit l

8.

SAFETY ASSESSMENT 8.1 USAR/ISFSI SAR Safety impact 8.2 Tech Spec impact 8.3 Design Basis impact 8.4 Safety Assessment Conclusion 9.

REFERENCES 10.

ATTACHMENTS l

l i O Page 3 of 3 Page 11 of 13

._.. =

a PRAIRIE ISLAND SITE NORTHERN STATES POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION NUMBER:

g TITLE

5AWI 6.1.4 g 35AWis.

DESIGN CHANGE DESCRIPTION!

SAFETY ASSESSMENT REV:

O TABLE 1 - SOURCE DOCUMENT INDEX The following references were used to prepare this Instruction:

AWI Section Source & Section O

l l

9 Page 12 of 13

s PRAIRIE ISLAND SITE NORTHERN STATE 3 POWER COMPANY ADMINISTRATIVE WORK INSTRUCTION