05000254/LER-1997-013-01, :on 970416,RCIC Area High Temperature Switch Would Not Actuate Due to Excess Sealing Varnish Applied by Technician.Caused by Personnel Error.Removed Excess Varnish from Switch,Calibrated & Functionally Tested Switch

From kanterella
(Redirected from ML20141A209)
Jump to navigation Jump to search
:on 970416,RCIC Area High Temperature Switch Would Not Actuate Due to Excess Sealing Varnish Applied by Technician.Caused by Personnel Error.Removed Excess Varnish from Switch,Calibrated & Functionally Tested Switch
ML20141A209
Person / Time
Site: Quad Cities 
Issue date: 05/08/1997
From: Peterson C
COMMONWEALTH EDISON CO.
To:
Shared Package
ML20141A200 List:
References
LER-97-013-01, LER-97-13-1, NUDOCS 9705140186
Download: ML20141A209 (4)


LER-1997-013, on 970416,RCIC Area High Temperature Switch Would Not Actuate Due to Excess Sealing Varnish Applied by Technician.Caused by Personnel Error.Removed Excess Varnish from Switch,Calibrated & Functionally Tested Switch
Event date:
Report date:
2541997013R01 - NRC Website

text