ML20133C463

From kanterella
Jump to navigation Jump to search
Testimony of RB Childers Re Welding Inspector Concerns
ML20133C463
Person / Time
Site: Catawba, 05000000
Issue date: 09/20/1983
From: Childers R
DUKE POWER CO.
To:
Shared Package
ML20132B649 List:
References
FOIA-84-722 NUDOCS 8507200503
Download: ML20133C463 (3)


Text

,

Applicants' Exhibit UNITED STATES OF AMERICA y,

l NUCLEAR REGULATORY COMMISSION 1

1 BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of

)

)

I DUKE POWER COMPANY, et al. )

Docket Nos.

50-413 1

--)

50-414 (Catawba Nuclear Station,

)

Units 1 and 2)

)

TESTIMONY OF RICHARD B. CHILDERS 1

Q.

STATE YOUR NAME AND YOUR WORK ADDRESS.

2 A.

Richard B.

Childers, Catawba Nuclear Project, P.O.

Box 223, 3

Clover, SC 29710.

4 Q.

WHAT IS YOUR PRESENT JOB WITH DUKE POWER COMPANY?

5 A.

I am a Senior Welding Inspector, Visual, MT, and PT Inspection in 6

the Turbine and' Auxiliary Buildings.

7 Q.

SUMMARIZE YOUR EXPERIENCE AND QUALIFICATIONS, INCLUDING 8

OTHER DUKE AND NON-DUKE

JOBS, EDUCATION, 9

CERTIFICATIONS, AND COMPANY SPONSORED COURSES AND 10 TRAINING.

11 A.

I attended Rock Hill High School, and York Technical College, with 12 1 year of welding.

I worked at the Westinghouse Turbine Plant for 13 9

months welding; Mac-Fab.,

Inc.

for 2

years as welding 14 supervisor; Daniel Construction for 6 years welding; and Duke 15 Power for about 7 years (since 1981 as a senior welding inspector).

16 Currently I am a Level II MT and Level II PT Inspector.

I s..

8507200503 850524 PDR FOIA 4

BELLB4-722 PDR I

, ll /t/_ 7g 3 rsi

f A

r 1.

Q.

ARE YOU FAMILIAR WITH WHAT IS COMMONLY REFERRED TO AS k

2 THE WELDING INSPECTOR CONCERNS WHICH WERE EXPRESSED IN 3

LATE 1981/EARLY 1982?

4 A.

Yes.

~5 Q.

WHAT IS YOUR UNDERSTANDING OF WHAT THESE CONCERNS 6

WERE?

7 A.

My understanding of these concerns is that they were focus on a 8

belief that our higher supervision was not supporting the Welding 9

Inspectors.

10 Q.

DID YOU EXPRESS ANY CONCERNS AS A WELDING INSPECTOR TO 11 ANY OF THE TASK FORCES OR TO DUKE POWER MANAGEMENT?

12 A.

No.

13 Q.

WERE THERE ANY CHANGES MADE IN THE QA PROGRAM AFTER 14 THE WELDING INSPECTOR CONCERNS AND THE TASK FORCE 15 INVESTIGATION OF THESE CONCERNS?

16 A.

Yes.

17 Q.

DESCRIBE THE CHANGES OF WHICH YOU ARE AWARE IN THE QA 18 PROGRAM.

19 A.

While there were several changes made, one that comes to mind was 20 that Art Allum was put in Charles Baldwin's position.

21 Q.

THE WELDING INSPECTGh CONCERNS HAVE BEEN 22 CHARACTERIZED AS CCW INT ABOUT THE QUALITY AND 23 SAFETY OF CONSTRUCTION AT CATAWBA.

DO YOU AGREE OR 24 DISAGREE WITH THAT CHARACTERIZATION?

l 25 A.

I disagree with the characterization.

I believe that the plant is 26 built with great quality and safety.

27 Q.

DO YOU BELIEVE THAT THE CATAWBA PROJECT IS BEING 28 CONSTRUCTED SAFELY?,

A..

r 1

A.

I believe that Catawba is being built safely.

2 Q.

IN YOUR VIEW, HAS THE QA PROGRAM BEEN EFFECTIVE WHILE 3

YOU HAVE WORKED AS AN INSPECTOR AT CATAWBA?

4 A.

Yes.

5 Q.

ARE YOU AWARE OF ANY DEFICIENCIES IN CONSTRUCTION OR IN 6

THE QA PROGRAM WHICH WOULD CAUSE YOU TO QUESTION 7

WHETHER CATAWBA IS SAFELY BUILT?

8 A.

No.

9 Q.

IS THERE ANYTHING ELSE YOU WOULD LIKE TO ADD TO YOUR 10 TESTIMONY?

11 A.

No.

12 Q.

DO YOU CURRENTLY HAVE ANY CONCERNS ABOUT THE 13 FUNCTIONING OF THE QA PROGRAM?

14 A.

NO.

4

\\

15 16 17 18 I hereby certify that I have read and understand this document, and 19 believe it to be my true, accurate and complete testimony.

20 21 22 Itz/a j d MI A 23 Richard B. Childers 24 25 Sworn to and subscribed before me l

26 this p g.A day of September,1983.

l 27 l

28 4

29 L 1-, b]

J 30 Notary Pub 11c 31 32 Commission Expires #2u1 1,

/f f.3 f.