V CALCULATION "5 " : 0102-00065
. , PACKAGE VECTRA PROJECT NO: 0102-00065 CALC.NO: 0102-00065.F02-004 PROJECT NAME: CLIENT:
Pressure Locking / Thermal Binding Evaluation Detroit Edison - Fermi Unit-2 Plant CALCULATION TITLE: h/h Evaluation of Stem Growth Unseating Load for Valve E4150F001 of Fermi Unit-2 Plant l
I l
PROBLEM STATEMENT OR OBJECTIVE OF TIIE CALCULATION:
The purpose of this Calculation is to determine if stem growth is sufficient to preclude this valve from performing its safety related function.
Safety-Re1ated DOCUMENT AFFECTED REVISION PROJECT ENGINEER NAMES ANDINITIALS REVISION PAGES DESCRIPTION APPROVAL /DATE OF PREPARERS AND CHECKERS j 0 Abb Initial Issue
/ /
2 b dd &
fh'. h5 1
PAGE 1 OF 7 9608130081 960807 QPES 3-2.1.1 PDR ADOCK 05000341 REV.0 P PDR
VECTRA:
Naperville, Illinois 1NEORh1ATloliOffly PROJECT pressure Lockine/ Thermal Bindine Evaluation FILE 0102-00065 OWNER Detroit Edison Comoany CLIENT Detroit Edison Comoanv Fermi Unit 2 0102-00065 F02-004 1.0 Purpose / Objective The purpose of this calculation is to reevaluate the maximum allowed unseating load due to stem growth for valve E4150F001. This is due to the temperature changes between the inside and outside of the valve body. The temperature inside the valve has been increased to 561"F and outside the valve body is 65 F. (Ref.1) 2.0 Methodology The computer sonware program MathCad 5.0 will be used for this calculation and will be treated as a hand calculation.
The methodology for calculating the thrust required to open an MOV subject to thermal binding due to stem growth is based upon calculating the increase in seating thmst due to thermal elongation of the stem. This is done by calculating the free thermal growth of the stem, and then '
using the stiffness of the valve / actuator assembly to convert the change in length to a change in seating thrust. The unseating thrust under the~ thermal binding load is then calculated by l multiplying the thermally bound seating thrust by the ratio of the normal unseating thmst to the I normal seating thmst. The calculations are done using the design inputs as follows:
A. Valve / Actuator Assembly Stiffness Under Thmst Loadine The stem is assumed to move at a constant rate of speed with a constant rate ofincrease in thmst during the period between seating and control switch trip during valve testing. The motor speed during this period is assumed to be known. Then, the stem speed can be calculated from:
Stem Speed = Motor Speed x 1 minwe , Lead 60 seconds OAR :
The motor speed is assumed to be given in revolutions per minute.
The rate ofload increase is calculated directly from the measured values of thmst and time.
Load Rate = '^'" ~ #"'"
CSTrim, - Sentrim, REVISION O PREPARED BY/DATE h kff, oF 7 CHECKED BY/DATE // // /g
~
VECTRA llIFORWTION ONLY Naperville, Illinois ;
PROJEDT' Pr' essure Lockinc/ Thermal Bindine Evaluation FILE 0102-00065 OWNER Detroit Edison Comoany CLIENT Detroit Edison Comoanv. Fermi Unit 2 0102-00065 F02-004 2.0 Methodology,(Cont'd)
The stiffness of the valve / actuator assembly under thrust loading is then obtained from:
Stiffness = Stem Speed i
\
l B. Ratio of Unseatinn Force to Seatine Force The ratio of unseating force to seating force is assumed to be the same for the thermally 3
bound condition as it is for normal valve operation. Using values from an opening test )
performed following a closing test at operating conditions, this ratio is simply: l Unseating Ratio =
MAX#*"
MAXcia,,
where: MAX, =
Maximum Opening Thrust, Ibf.
=
MAXao Maximum Closing Thrust, Ibf.
C. _Slem Eloncation Due to Thermal Expansion The amount of stem elongation due to thermal expansion is calculated by the familiar L x a x aT equation. The stem travel is used as L due to the fact that this the only portion of the total shaft length that sees a change in temperature.
Stem Elongation = Travel x DeltaTemp x TempCoef where: Travel = Valve Stem Travel, in. .
l DeltaTemp =
Change in Temperature, F TempCoef =
Modulus of Thermal Expansion, in/in F l
REVISIs O b9h/, PAGE 3 PREPARED BY/DATE oF 2 CHECKED BY/DATE g // g
- l. -
VECTRA l- .
"anetviiie. iiiinois /// FORMAT /0// 0//Ly PRofEC'T FILE 0102-00065 Pressure Lockinc/ Thermal Bindine Evaluation l
OWNER Detroit Edison Comnany i
CLIENT Detroit Edison Comoany. Fermi Unit 2 l
0102-00065.F02-004 l
2.0 Methodology { Cont'd)
D. Total Force Reauised to Overcome Thermal Bindine Due to Stem Growth The total thrust which is holding the valve closed is now calculated as the sum of the thmst due to normal closing plus the additional thrust due to stem thermal growth.
Final Thrust = Max a , + Stem Elongation x Stiffness The final value for unseating thrust isjust the ratio of the normal unseating thrust to the normal closing thmst times the thermally bound closing thrust.
Final Unseating Thrust = Unseating Ratio x Final Thrust The acceptance criteria recommended for use in this calculation is that the available motor operator thmst capability be at least 120% of that thmst required to unseat the MOV under thermal binding conditions. The 20% margin is provided to allow for uncertainty in the measurements used to calculate the stiffness and the unseating ratio as well as other effects such as valve - to - valve and motor actuator - to - motor actuator variations. All of these effects are random in nature.
The available motor thmst is 26,667 lbf. (Ref. 2).
l 3.0 Assumptions A. Stem Motion The valve stem moves at a constant rate of speed with a constant rate ofincrease in thmst during the period between seating and control switch trip during valve testing. l B. Motor Soeed The motor speed during the period between seating and control switch trip during valve testing is assumed to be known in revolutions per minutg (rpm).
REVISION $
PREPARED BY/DATE d Mk oF 7 CHECKED BY/DATE hg //u/4 -
l .
VECTRA llIFORul/TIOliOfILY
. Naperville, Illinois PRoJfCT Pressure Lockine/ Thermal Bindine Evaluation FILE 0102-00065 ,
OWNER Detroit Edison Comoany I CLIENT Detroit Edison Comoany. Fenni Unit 2 0102-00065 F02-004 3.0 Assumptions,(Cont'd)
C. Ratio of Unseatine Force to Seatine Force The ratio of unseating force to seating force is assumed to be the same for the thermally l bound condition as it is for normal operating conditions observed under testing. I D. Uncertainty Marcin j l
A 20% margin is provided to a!!ow for uncertainty in the measurements taken during testing and the unseating ratio, as well as other effects such as: valve-to-valve variations, motor actuator-to-motor actuator variations and running-to-non-mnning stiffness ,
variations. All of these, except for the running-to-non-running stiffness variations, are !
random in nature.
4.0 References
- 1. Form 4 to VECTRA report number 102-065.F10-001 Rev. O.
- 2. Fax from Paul Otal to Susan Korn,"MOV Torque Switch Setting Calculations Input", for PIS No. #4150F001 of Fermi-2, dated 1/26/96. Fermi Calc.No. 768850, Rev. A excerpt.4 E
%Lddu @O ^ d" h ' <
Md l
- 3. Fax from Ed Cavey to John Kelly, dated 1/25/96: JeadanGJd 2-) g 9
ikhh- u?,$
e VOTES Test #3 dated 3/l8/94 for E4150F001 j e VOTES Post Test Evlauation Data Sheet for Test #3 for Valve E4150F001 1
- Page 37 for DC 2712, Revision H
- 4. Carpenter Stainless Steels, Page 94, Thermal Expansion of Type 410 Sta ss Steels.
REVISION O PAGE 5 PREPARED BY/DATE M/fd CHECKED BY/DATE g f/g /gg
VECTRA Naperville, Illinois ((f[hk[g[/gg g PROJECh pressure Lockine/ Thermal Bindine Evaluation FILE 0102-00065 OWNER Detroit Edison Comoany CLIENT Detroit Edison Comoany. Fermi Unit 2 0102-00065 F02-004 5.0 Desian input:
J Stem Travel (in) Travel = 9.375 in Reference 3 x
Change in Temperature (F) DeltaTemp :500 Reference 1 Mod. of Therm. Exp. (in/in F) TempCoef =.0000065 Reference 4 Reference 3 (Stem material: A182 TP 410)
Max. Static Closing Force (Ibf) Max cjo3e = 36910 lbf ,
Reference 3 Typical Thrust Trace Max. Static Unseating Force (Ibf) Max open : 16548 lbf Reference 3 - # Seating Control Switch Trip Thrust (Ibf) CSTthrust 32157 lbf Reference 3 Control Switch Trip Time (sec)
CSTtime :38.764.see Reference 3 Thrust at Seating (Ibf) Seatthmst .: 1192 lbf Reference 3 Time of Seating (sec) Control Switch Trip Reference 3 Seatt *. :38.607 sec Motor Speed (rpm) MotorSpeed =
Reference 3 min Actuator Overall Ratio OAR = 30.50 Reference 3 Maximum Thrust Stem Lead (in) Lead = .50 in Reference 3 REVISION PAGE 6 PREPARED BY/DATE M/f4 OF 1 CHECKED BY/DATE g %g ,
7-
r 1
l - -
VECTRA
. Naperville, Illinois g/P0R h(([g/[ 0/! Y PRoJE'CT' ' pressure Lockinc/ Thermal Bindine Evaluation FILE 0102-00065 OWNER Detroit Edison Comoany CLIENT Detroit Edison Comoanv. Fermi Unit 2 0102-00065 F02-004 6.0 Calculations:-
I'*
Stem W ::MotorSpeed """- Stem 9g =0.519 5 60 sec OAR sec
, CSTtivust - Seatthrust l Staticrate : Static rate " I 97229
- Ibf t see CSTtime - Seattime Stem speed Stiffness .: Stiffness = 0.000002632 in 1 Static rate Ibf UnsentingRatio : P*" UnseatingRatio = 0 448 Maxclos, StemElongation . : Travel DeltaTemp TempCoef Sf:mElongation =0.03 in I "E"U "
Finalthrust : Maxciose i- Finalthrust = 48486 lbf Stiffncss Finalunseating :UnseatingRatio Finaltluust Finalunseating = 21738 lbf F avail = 26667 lbf Reference 2 F ,y, i - Final unseating
-100 Margin = 22.675 %
Final unseatmg 6.0 Conclusion This valve is capable of performing it safety related function based on the results of this calculation.
I REVISION
./ /
PAGE 7 PREPARED BY/DATE 47/ 'd(#74 oF 7 CHECKED BY/DATE h //Q r <
l
l itc. . Ote2-Oc85.Foz . ,
"~
Alle)- 1 i PageiJ7 l l 1
." , i j 4 I Fax Coy l er Sheet IIIFORWTIOli ONLY \
I !
DETROIT EDISON-FEIG112 l i
! l 1
l l
OATE: Ianuary 26,1996 TIME: 2:03 PM TO: $UE KORN PHONE. 708-778 4 244 i YECTRA PAX: 708-778-4444 l 1
FROM: PAUL OTAL PHONE: 313 586 1739 l FAX: 313-586-4911 4
RE: k4150F001 cc: d.SCHERMAN Number of ; ages including cover sheet: 7 Message OPERA '^0R CAPABILITY CALCULATION i
I i
\
i I
l I i i
i I T0*d TT6P ??S ETE 8 fM3:1 N05103__130 __ ____ __ _ _______ _ _ 02 :PI 966T-9 M r
- h. 22cecs.rc2.ecu N ,.I a E
r y.m.
..e.
-timGfOMEQ@%^.nhai$yJd60GE/48NhND54tDMW
- ~ ~ ' r ~ ; ' m :".s.- _ =r.-- . . . . - . .
3 y 20 t
L. wg .; Jc.. E - .- -
t
?^" W..Q 8200:'rs;n.4l.. : ; :* .:.
PRCUECT ho.
i ' . h*'F M 1. 02/09/94
- , C lu . .
i
'; {~ GALC M V A
.. . Yey? . W~. * .' a' pif .
L .. ..._- .
.. TABLE 1-2.1 l
Ek * '1$$ : l
- ..' FDpgl.2 / '
$g~. l. . 'A'h;55
. t h- G ; b.X l.Y l[Y m , ..' - -
..4. k?il.'M.7tRRE .$ ?: SWTTM SETTIhG CALCILATIMS IAFili i .
_ _ , g.,,,, .
1 ., :.y.:,~.,; -
-a
$$ i 1
. =...;'1-.. . , 4
' MVE DSTA:!
REF AC.
' M--=
l
^
- 3. . !
... .LVE T.YPE , .? [1 ]
MW SIZE i VSIZE - 10' [] ]
. i VALVE M(htfACTmm 4
MANF = POWELL [1 )
- VALW SGIAL, huBG VSER = 656681 [] )
M DIFFERENTIAL PRESSWE ON CLCSE VALVE DISC (PSI) VALVDPC ~ 0.00(.x 5) 1 1
M DIFFERENTIAL FRESSWE W OPEN VALVE DISC (PSI) VALVDP0 - 1169.00 (2 )
j VALW PAOClhG FRICTlW LOAD (LES2 FPACK - 2125 ( 3.4 ]
- t
( '
o 5
~
VALW FACTM FV = 0.400 [.9'&
l VALVE SEAT GUTSIDE DIMTER (INCH) W - B.250 ( 9't S]
. t i STDI WTG DIA%18 (lh01) STDDIA - 2.125 [4 )
i t STDiSPG0 (Th00 MIN] lK.T~: ::.:: - MA (-4-- ]
t STDI THtEAD LEAD (th0UREV) LEAD - 0.5000 [t ]
STDI FACTM DIRECTLY INPUT? IhPUTrS - YES [ NA )
_DlMCT lhPUTiVALUE OF FSGWo.16 D= k Q,,5 FSIN = 0.0198 [ .e'b]
l
- --STDI PITOI (InOES) P = 0.2500 (4 ]
.. 'inLF TNtEAD hGE (DEMEES) ;
ALPHA = 14.50 [3 )
1NtCAO FRICTI,M CWFFICIENT NJ
- 0.150 (3 )
..y . .'Q y 7.t soL c 6 1; w w < c7 A uve Ha.s sw gpa gyn.ams .srof v% vu ( A v s e fat.1) p c THa
( wTnoc. 4'v' (A W'~0 fo'Y.) aAsurm
. si- svia e aoi.
pp oR m rF TMse ~Zwo vs <. vi.s ,4,Lc c row 0 fs2 wit.
s 4:' Lev n Z4/10 Fee I [/'l WG - A c'T M tJ/t t
( graues rhw MON 1s' 2E12.0.
a, S.a & m aerna i.o o r oc 10 v i vot z &.A i
l M [/h.6 N*M M M EY N M O I Mv/ b b SA N5%O N- - GE " ' ' "* ~ ~ #' '"
w iypre_gegyng E EVEe M!@ N@ 123 E t'T W- "
c .(* w R?.r M . & d.,I
. p.E d
.. ...-; - .mn. . . .
7.[* h M I N d M D N rk N hWN 4 y y3 M '
.~. . <. atm. w,-m.,9. 5 as:. p. u, .,y..a 1, . 1
- .~ -
. . - . , ~ , . .
PMXCT m. 1
'j!)'([ .({,g g.'gg.f. .spoo . . e. 02/09/94 T.:.;n. !@-gGALC Mii A.
- 1
.'. 14.2 1
lYib$5f5:$$x$$57.) . , e c. c,gg,.g; ',3 .
,.,j.,,,.-
'*'~A b" . 'b, '* A *
.WfyW:g..;g. .9**.WYW.'*:'i ^ * ' N2 i;*'A'4 i
'. w- -v-. -
.p.s . . t.?v .q%.. c'm +w:. 5
- b. mv TGRour : SWITm SETTIM CAlaUTIOMS 191T
..Q'.* e' - . . . . .'
, g . .;, _'y .. _a ** '
-l VALVE, DRTAltaWTIMED): .Kr m.
. '..~'.?. . !
hillECT IMUT val % OF LIMITIM VALVE 7mLST (LBS) THIN - 45900 (8 )
DIMCT I@tli YALUE Of LIMITIM VALVE TO90VE (FT-LBS) TQiN - 909 [B 5 y gn N 'f*HI N x f' $
& sipop>A6/98= 109 i
yg gy,1gs a s s.c= 7~H M .1 T : H % 'Wu D 1 E"b
( (. . l l
f . g. .$
- k .
i
.~ ..
..,'..l..,. **
.l I
=.f,... .
., W. ' . . .
. 9.Q 4
~'.,
.o- .
- ,. i '. T. *. .
- h[*,i . .Jij (.*., . . . 1. . . , ,
.-* . t ., s .4 . , . . .
- g. a . ,7.'*"*.',,..
- ; . ,..Q d'
'*~****.
j .
I . .M. #,[.J . .. . q ,'r=8, v.- %*. *- . . . -l si. ;. :yy .. .. . .
l
'~
, 1> *
. T * ,q' . .
I f... -
i t
C. ..,;.., . ' '. J f..* "i,
'-..,.1
- .. l
.. I;.%. . * ,. 4 a
..:*.. l
,g
'. 4
) J. .
I M *c'l ERSF/ @!R RI)t P2 WLtl-f FOSIG; iM T?:t T C#,AT CP-8sw
- i Aalc StC'Z,ccc.a; A '.-CC.4 M ecn , l TA.4 4 7 I
R n .g m,
P M* : m. f ,. T~r...M$i@hr.s?diMis%GF1571GCETi$
yM.'.2.ssn..s. .? je-
~ .
5 0F 20 i v: ?. n-t- x~. :? ..-y# ERD'.4 w;1 PRCUECT hD.
VER510MT.1 1 . -
. .; ' . CALC.10 ' 788850 02/09/91
\
s- .
- .'N
..:'W.. 'k .nGLC. REY:. A -
TABLE 1-3.1
! .. 23WW}r'd.g.....& ?? l z.: $ ; 4 FEmla -'
i % g .rs.n.. MM g.. QM SETTM MMTM IM7/Oly 8 ., .
.Gi . .
' y _7 <.-l
.%"'?$
?
.~s. g .y-:y 7 -
i':bM.i
- .W - ;PlS h0:.E4150 M 1
- y. : . p '
.. .+ .
Win (TQt AhDinhEMEEL MTA: REF h0.
WERM.SDilAL AUBER QSER - 195642 [] ]
- I 4
WGATER NRM,FACTlRER 04ANF = LIMITOROUE [] )
~ 0%MTER hanE1. 04 GEL 1 I
[1 )
WDt4TER SPRim PAG IGEL hV6ER PARTHO - 0701-212 [.,# M) 4 i
i TDRQ T RESTRRINitG M YlCE PRESENT MYlCE - 40 (9 ]
i
} N(XIMM SPRlhG PAG SETTIM 7040VE (FT-lBS) SPRIMTQ = 838.C ( 40'3] ,
- . o MTED 107ER WEMRR TIRLGT (lSS) 4 :
( l RATeTrG - 45000 (.6 3)
- MTED IC7tn WEMTD17090UE (FT-LBS) RATETO - 650 ( .& 3]
i i
O(R DIRECTLYlIhPUT? INCAR = YES [M )
ulRECT IhRff;YAL% OF CAR
}
i GARIN - 30.S0 ( .i )
- IS TAR TRAIN SELF.l0CKlhG IN LIMITO70UE SEL lhDEX? GLOCK - G5 ( Ar y]
MINIMMRIMhLILBS) i MINRIM = 50.0 [3 )
1%XIMM RIN PULL (LBS) htXRIM - 160.0 [3 ) .
^ i IND& EEL DINETER (ih01) FDIA = 12.0 (9 ) '
MhD6 EEL GO,R MTIO MqATIO - 25.3000 -
(.& 3)
MhD& EEL CLAR EFFICIEhCT HEFF - 0.3000 ( P .,3) 4 i i
i IHhD6 EEL N(MIMM ALLuiABLE QUTPUT T090% (FT-LBS) i h0VTO - 1900 (.5 3)
NUD& EEL IntlMM >
AtlasABLE INPUT TotOUE (IT-LBS) MLTQ - 250 ( $ 3) i d
. i l
, r. l Q $
i I k ,
l
'i re s tisp ses at a imsa mstansa zz:rt 96st-9 N
r 4
- o. I 1
-mm +g ..-4.g'~:2g.r
.Ww qpp^~ k.. .%35WWW . . ..a ..#.1 .v.ne.:
Q ,; & ?.*Z hy .v+.w.t g%>< Ny H) '?-WE'"
6 W 20 i
{$5?b*??~$.%45$
y..- .u-r.~.:y ,.
- h MECT m.
1 _k . ..t 1.1 ? 02/09/94 i .- A 10 < .. ' '
,N i
' :h*j'i#.
c2.*D.y.seh.'/68850 4TC4LC'JIEY.' Ai..'
4 :-QiWR.,- l ~?
^ TABLE 13.2 .- <-
-w;.m~*.s .c rar~ =g%n; .a.ap %*k.;a.1. '.T s..:.2:.,. .g & ..r. ,'.: g s L,;
u\ hp%.15't - m.~.;:.
'.? : m- <
~ . .. .. -
...; .?y. h.;1,.~y. .v
.p". ;p:
' W=
~
.r.e wm; .
.,.s
... .r.3 .
~
MV 1DillE SWITm SETTihG CALCMA!!QWINPflT
. . '$YSTDI: )9CII "
!, -?
.,....P15. M: E415 W 001 I
REF M.
i WDt4 TOR AhD'NUDofEL LMTA (CtWTihUED):
4 i l i 10ltKE 9173 SETTim GRAPH SLTE M - 0.00264 ],3)[ W ]
TORKE MITm SETTIM GRAPH Y-AX1S INTERCEPT 88 - 0.53808J[ 18~ ] l 4 i j TQttXE SWITM SETTIM IPPER LIMIT LI M ~ 2.75 },3)[ M I l' TORKE SWITCN. ' SETTim LSER LIMIT Li m = 1.00 b)(.1&*] 1
. I g* is 1.0c =
g .7 5
.: J. so z. 4 y t -M5
( AA - l 836 -/ 7 5 j,oc - o.oozbY=17S: A 6'b fo 8 l y. l i t'
. I i ..
! + t . i q
- I l . . =* ,
. '= * .:. -.r.s : n . \ s.. . . . . . . . .. ..
j , ,y . ., . . . .. ...
. . .e e . . . . * . .
yc. .[ *,"~ , alle s*.'. . l *
- r. . ,,},'/ l l
*g'"*?. .* a.Q,.:a.: ., ; Ec2.? . ..'n$
- s. . ..:: .*
*1.-
3
,? -
D ! 6: - ., i ? a . g, .,,, ,
- . p. ./. .-
- ,
a r ' t *l.....
. . :r .. .. ,
i :.' .
\ "..fr i .
t , gg.- '- a e
.T y.a ' t 1 1 . . r. . ]
1 . 1 so a itse ses tit a masa N ms .tss ae:r: essi-e m t
. 'I.,
w i-vN h 562.-ntll % g,j, % g, gg{
^
r
- h p
~ ',' 1 4 --- -_ e - --
l . ..
. I N W'
- s- mw p%.w - s...
a=__w w MAL.4 m ,. ,w&.. .,--nwcmpsi4-
- ,s.+ _ :: .,. .-@&o.,3._..,.
n.m.w.nw.. %W.v.e?
.;.z ,4.AWEQ,- u...p- .
em.w w x.- e 9~ ~ . ~ ,.- : s.' m:.;.m. e- upn,Lhg...
- k?.'
.~ . . '. .: ~
7 W 20 l , .gy. 'T' . .=ff.* . ;.-IQt 1;)
. PRt1ECT AQ.
l :6 ( ,.,D..$i.%.C
. 10WC A .. . MV .768R50 ..'
r M109/.%
- .~ L W
-TAate 1-A.1 ,;-- .l=..
i V z:ph.
- u =.%sp.F_6:_%.iy.Mhil . Sg yd, , "$ f.y.W.y*pyhi. -t - . .. s. . c y, , .-. ?:'
l arl _= . .:. t v.u y .r ,...:. W., . . 'eg -
.}. ,, . ,
j?,Q:(.5 l' K CALClR$7CM JhRff 4
- 7. .i M cry'c.; - . . , w. .i 1
i 9~.:f'.f.Kn..;.. . Y.z;.*.
. is ho: E9soms =-
i < .,' M D S TA L,
~
I - REr m. i \ i *M SDtIAL AUBER () t MER - UB79 m y i M M44tFACTZRER l M MMR!TYPt
- MF = H.K. PORTER (1 )
- ACDC =. DC (2 ~
l MIN.ntM ROXXED VOLTAGE (VOLTS) MINy - 153 y 1 ; [ 3,7 y 1 AQtIhi(L Kl.TAGE (Rt.TS) . , .. . m - 250 t1 ) , . NMR SPEB ;!RWt)
, - t % - M0 [1 )
s MELGli UTKIEKY t ; PE - 0.80 (4 33
- . AM'LICATIQV FACTal
- AF - 0.90 (g3y
- M STALL GFICIEWY
- ; st - o.5500 ( g.,5y i
RAM M tut 0VE (FT-LBF) l , MT - 13.80 G [-t- y
- L5,83)
? 'OC 4 AN b fJN h /4 .5. $~ fo it S-r,.c g i d 2 s.4e g e es T~
a, .
- t . y.,.'.L.
. " N g, 'g' * * ~ 4. AtM l,4rnt.
duow: k' ] 77 7 sTA<.y Depa.a = g z Fe. Lhr.
~~
1%9) IoF .$74cc. ~7~osMui . 1(8a.) - y3.8 8
. i ,g .m .
f (.
. l i. . I l Il 90*d TT6# 99S ETE _
_ E IWhl3d NOSIC3 130 E2:ti 966T-WM
a 0 ' d -'0101 ,$ ic, M .,. g r/. p,,; . A g 'A g,, g 7,g ,g-- ! TC&hll n Eu g sff% # fg rte Ilv% M
.-aars. z d.x 'c K.W * * . 4*..,
0 Mi EO
- .L:".: M- yk .. .JwuQ'* ,
.T.; .^.e L t -
{ .7.: e2003.Q~4u g ,t.)qs % ' ' . . : * *r e .p. r , PL'ECT m. gc'..QWBtSIWiiib.yP..t.-..T.''"'- 02109l94 CALC 10168850.'T . w W: .n.t.4.:>GALCREY.'
,;-;- ...g-n,sc.,q. .g.:.,..A: . , herg;', . . . . =..y .. . .H.:.:. . , .,. ., . c .= . .. - . , .. c $$$, 5h... kb.-...s.. .. ..T.ABL.E.s 'N 4.1..
r.? ..'. .I '
- y. n ~ fY s .
*m
- ..~,'...--mune.wTTmsemm c.uaurims amr ux.: R .;
. ., M . ys.*....-et..T .. . y ,
q- _ ' + $ M : [4]$ W N1 : . :: c.-- : --
. . . ., , .,.p - . . : it -
- p. ., ,
R1TlR @Dl41M RITPUT TmfET AhD TMOLE CAPACITY CALCILATIW DUTFUT: (DEGMCED '
.. t nx.TAGE) t REVISED MillR TURKE (FT-LBS) MIT - 48.12 ,
e : .{. ;
..RNT, = Mr.* MINVIhmV *' :.v- 7.c.;.'.:
- o',. --- - -
.+ .. .s. . . . .t.9
- p. s,.t' ,
' NIH CALCED MTW OERATm OITPUT M70UE (FT-LBS) WTOCUT -
528 WT3xli = G4R
- PE
- AF
- RNT l
( (' l mu cuauTeo mim ootMim amuT TmusT nss.' w
~--
re our - tess? I . wTwoUr - wToouTirs 1$ : t hDTM @EMTm DUTPUT TPOUE CAPACITY (FT LBS) OPTO - 525 I
. WTQ = minian(OPTOCUT.MTETC.SPRIWTO) l - ...,...... i. .
- hlRM WEMTim OUTPUT TWUST CAPACITY (LBS) @TM - 26667 i
eim ~ miniantwTwovr.MTETM.WTQlF5)
.: < - .i-2.ts., g 1. ;s bo.a d. ca .P3 ..n-l ! f u_ ut LR y J. : . .
26' % 7 -
..- !. 0.9 - 29'03c Ws
(.....' .( l,
...a ** .. ** .I , .'t... ." - i.
4 ~
,, .;8 g . .r 1 _LO*d T16t' 995 ETE 2 IWM3.d N05f C3 1 3 C? t'; :ar.ct cNw
01-25-1996 05:25Pt1 ROM "TE E:2 65293 TO 917087 92444 P.01
- 8. . . +- = c a ics . v e z . x u l '
! Dekait EdisadN #"[
I F Fermi 2 Pisawat ; i
\
i
- i Q,_m' il .....:. s IlIFORI4ATl0!l OfILY l l f
i . .. . . ... ,xp . .. . .g ;p n '__ 3_ i i 2 i TTR AMTEisWrYSSIOl%T 5 I CO6 R ; i ! 1
- i
FR.OM: ED CAVEY i . j l MOV COORDINATOR . i (313)-586-5069 FAX-(313)-586-5293 l ! ! l TO:! ' To k KELLY !
, OEcAus La attM > .
! ; i i : o - i i Nd. o; f pages (inc. cover sheet) - / ! l ii Message: l :1 i
- i i i
- i j
t i i , i ! j u., ' unos.r. c..,
',q - l i, , g.g, . ,. i s
er, aw.y ww3g:::;m _ 3. ' ' ,, l
*,1 a -u "i ms,_y 3
pt o a mym a......an %e , , ,,.
, p.. .. .. +. .
i A$' l
. /,'s f. ...
g 4
,.8D.. _ ,
l
- j i' i .. . l
01-25-1995 CS:MFM FPON NTE E:--' .a: m-YDN
*- -- %Mi$d&$$$$f . g-~w s
gg : yg. g#.s. n m W;;%:;J
'r..
s y;mN .. :,%<y,
- - Ju;e -f p. w ..
M. .n;y)+* .K* ,.., . T. HVFO% notj H. 5 .;:.;. .%% f;F Test Results Sumeat-g.a, :~ - s mp.esa.
.,3. . . ? M ".'.M., !
Unit: 2
. p.:.ptggy gygy,rpee m e:- . . . .. . . dy. M . ,,. .e !
D- .witt.*.7.g
. Valve. Tan Humber: E4158F001 r 41uator. .d-.c.- ?v.:.w.:*_ " 4 w-4 c. .c. . 3f. ; ;/. . . ; .y
- 2. ... Test;, Hun 6e: r-3- [:
i m- . ,.:est:.Datet:'
-y . ..... '3/8/94 j i;. ., ~'" 4-Rg[$,M,y:":.k.$i-':.*.q:
- A .
- pr:My:
W_ Y 4mm Ed11topenav<. Full Closed ' 8 l t.;p, le=SBPMMg..,.:F;VPM.. A- - 0 O' 0 hg3 Jpstream.iPressure NPSI) . 0 0 g iDownstream Rressure (PSI). 250.80' volts
....DC I:/~40toGyoitaget.'.:%7c.L'F..- 'A # ~- !
M*g*,- lMN4SM.. tin'i Sett i en-Torque-witebs??@ing 2,500 ; 2.580 T. .. ~oser: Torque;seite t setting.--- --------- .. .. .---- ' I W.$;i P 2-t Mrati4W(secEnds) ~vc:rt. s '.sv:ver. Closing .69 13. 775. tr~i;StrokekTinei <C.'7W itch .m - Opens seconds 13.433 s streke '.47. 51 7.:. .. ClosenToreuesB'fp'asi Sw O.1 r3 i i; Sea .
..v:; m. ting .3 g.T.iner.f .-.- . ,. Opening 13.417 i t .Strokw.:T.ime 'd[ pass Switch -- Opens seconds 12.620 s. Sten.a. '.e. 5:*. ;f;3- Open, Torque .- !
Calibration Range: 13271 t o -36,8 M 1 :, s . ' 3:. .i t '" +;.Pb.rcesi' C i.. ilbs) Clostng
- c. .* i l -2526 Mar Anning F6ree 3 -1495 .
Ave Thfusit. N nnino.Fcree At Start of Wedging -1192
' l t2157
) p ThrurM Maxia 4htust; at-CSTi - . ?.
-36910 -30965 l ~'TTAvatE.wle. Thrust Margin Openzn I
- . ..w..e. c er i Initial ~ Thrust (At Motor Start) g
-35458 !
7" 16548
+ 1392 +.;Dise. Pullout Force Max Running.Fbree 777 ! . ;./.". Ryg R anni n g . F o r ... ce. . .. . _ - . - - - - . .. . . -- - -- - . -- -- - - - -- . .. . - .. . . . . . . .. #~ ../ Motor Currents tamps) i Closing 3 .f..- . f-sf.L 4. R . 2 . 2- .
Inyush:.Cutrenkr..'.
-82.8
- t:
-7. 5 i i f'"' Averag.e-RunningqCurrent . Opening 87.7 1 ~).-p%w %wm_ .ntushi. Cur rent T;:
19.3 f Mk trent.:8u:nnijng. athMalsimus Current Pullout Force 10.9 FG agei -- _ _ ---.-.. . . __..__ ___ __.__ __. i
--' . . ~ . '
f/S 2r.d time to
%e.-~N -Asfl .% Vsi"' -u T,chmentfE5.?..Jestes,tsghten 6koi masntenance performed.Rassedpasses nts t e durung s t;.;g e above ein. OPEA dessen. Monttoring by q%' s.v grust11er desired.a.B,osto.n e M1 r /
I
..~; e. ... i g......u,'
n h g.. 14 s .> l
- a,.'g..v:-
E' n.e
- :. r'p* wy.7.;e.rt:.y.W.
- ef.n.,s, G.;.f.n,,c?:' . b : . d'4%.
^)..<j; - g. .g?.~.; .t. % . ^ yak-jl?-hxcc .hrr 9.J G: '> J'g.:ZWj:&b~D7: s $ b N# n , ,h_.
fi . wt.:--
. %-. ,m. .'.'.9.. .
u ,7.,> L. ,0 ;
. ..-+q;,Wm.$$ ,,; . .m. hd.i.d.5@. f. '- , .
h< ;.- r .m ,,, ::~. .v. ~-,a - - - . g '
~ ~ --- . . , . .S".c c,.
W q
~.s.. ..- n ,- .:?:~u-se.. ; (. :.r,<.i. . . n. . ': : . ~- 3w . n..+ m ,n. . .-. ;.,y . u. , ,,..v..... . .. . .....a.~.
m . cx u..u :g;;.;;z..yg. . :
*wiag. iw.. ,w m -~; .-
l )
.y M4"'.jpD.v, _ . .n. m %,%-? , .. ..~...:. ';.l.M. ,. -.w . .. ~.
L -* g
. w#.&c;;,:mm ; g . .. . (.V2 a... . . . . , ;;. ,. n -
I g$ .-
95 ~:.bw.c.;r ..
- 2. .
b [-}' 2;.*h. * .' '*C'.,.. .f "jt g h, ~a ~ '._ ppgc%r.;&: r. : .- f Eh m'rr=0 m._ M = k$., b. ,
- - - . - - . - - _ _ _ _ _ _ _ __ _ _ __ ^ ~ " ^ ^ " __h._ a _,
ca-2s-1935 ct:=:,3 : , gg y., g.,_ I e ca)e @ l-coCb 5. Fo 2. -oc y 1 ! . . . .l. l N dM hgg
? f IIIFORWTI0llOlyy ,
I l . , .=
' m 7., m: u ncezwt
! M ientae: '
/;
! . lats* .3 //o .. Q Test M. maker: 3 Test kte: 3/tvM -
-4 ;
P.-u. TIER!ItalL c FfhgClosr.T.3,_m.2.. e t N ,- t P'w - . . m. . . - l Open i l
'n Timei 13.7'S seceMs Stroke Time 13.417 mA 37 ,
secemls Npas:: Time 12.829 secoMs l h,passTime! j 13.433 l
-2525 lhs fitx R:nning Term 1992 h-
! thz hunind Tas:=
~
I h l ihs Aug Hunning force 'a7 l j , h g Asamin5jTan:e -1495 l i lbs Dise Pullout Fcree 16540 ths. Tnenst at CST -3Z157 l l ,, j Aal. hAj Ay>s - / 7. 2 ! thximus Thrust -36918 N
}
- htt #A% hv/D- Vf Mai;lable Thrust ftusin -3!965 lbs ferv
- : S. Setting 0/C Z.50W2.5fB
~
I ' I ! . i 4 i , 4 : SpelosPaciPrelod the
' Calthration P.e.nge: 13271 to -36295 lbs. '4 l t -( /
4
. i I
k s l t l I ' Tor:Que %steh Setting Ocen/Close...............: 2.500/2.500 i timat Switch Rotor Aojustment (Y/N)........... : N H 0/ 1 Flaw (gpa) Start /Fintsn........................: 0.- 9 Upstream Downstreas Pressure Pressure(psi) (psi)Start Start/Fintsn............
/Fingsn.........: 0/ B General Cookents: :. i r.<.; t : .#. f.. :. c .
66 a t e t e n a n c e t e < f o r ta e d . R A t t.e d As le f t.' lube s t em. t i gh t s.n pkg. c o r. t a n . anitoring a< p a a 91 : . i n ;; in ; . . des-tred khr n111er amove aan. O vC r.
- w. Soscon /lT.pst ac ts V .
Valve Actuato.-
- V61ve Inf ormation Actuator Type..: LIn1 ve:t.qs tn.
Plant: FERNI S1:e...........: SMF i ;/c i t 4 . ., . . . Unit.: 2! ! r! . ' h u e. A4ts: * *# O u i i-
- 1. :. . i
- .T a e Hu m be r . t. . . . . : Ea150F001 Gers.G m.......: i <% . . s;... . . ..
t . .. . J,. ,., ..J T fe....;...!.....: GATE Order c........: 2- Jm ,P .1 ...
' Fun s. cud
- "- .."- z e. . . . :. . .l. . . . . : 10 25631 lbs Worm OcAr Teeth: 34
. rget Thrust. . . : ' t'E R T Gear Ratto.....: 3Q.% He.r se ': ow.s I rientation Spring Pacu n eeB/ !
ocation. . .l......: . . . .HPCI
- RM > TURBINE 5 tem Matermal...: A182 TY410 i
b/[.'[. 4 tem Diaseter...: 4.08
! hreads 1pett: Inen 2.125 4inenes { - -- _ h . .,y, c osipe :Rev.: 2
- e. r l ratston etto.: 114.3 x 10E6 psi Signal Conditioner CAltr. cat:rm he Dete.
dS seri I t..: 3.746E-0003 pv/v/1b (.';t
? ,Senstttvaty
- y. n .s .
s.d. A.j ,, ;i.1~ir &. '-d. . i . - I lm - - - - - - - _ - - - - - _
1 u
- i I
j
. . [hk . .p g}g g'T "';
- N .
fgQl - f g; ). _p :h'.sn >
,L] - - . --4}. --- - a _..p..cg2.a._ :: . ~ ~ ~ - -- - - - - . _ . _ , _ . ._o b;1;. .: . 1: , p. : '2 '?
}
- . eGSl ~
ev e. . ' , . w m.n y:p a.. iMM.'. . ... y yQt
^ .o ; '. - Description .
W .Lebirldi.~ , L . Time Current (as s) !! :
' . .U .>(msecs) .
({oice :(1bs)ncorrected). 6 .t.' . . .Notor Start 9:
. 'D .G?.;;.M P 178.t: .
32i.. .f. . . e .. T T 8 .' ? h: N.] p://c,.'*:g 3:e.. - 54 ~: A .J atf2 ,5&ly; gS? Jilost" Motion(Current Region (Hear Middle) 91 "- ' t... Inrush Hammerblow/ Start of Peak Sten Decompression
~
yt[Jd.y'jE ;; 72 4
~
F 4 5' m ; C
. , . 60 79F ':'M~35101:/. ~ ' ' 9 tm
- 9.5~ Stem Compression Fully Retieved m 5' . . .
/ ~ ~ .~.
40
' O 9.5 Zeroing Point for CF Cattbration #3 Stem Takers up Disc Clearar.ce 76H7 CF . - -05 771 2501 10.5 Maximum Force at Disc Putlout, n.
09 825 16548 19.3 i.'! 2: 839 9320 23.2 Opening Running Condition (Hear Begin'g) it] l
. .-4 PUS ~.
013 1721 1164 11.0 Opening Running Condition (Hear t~nd) 014 ' - 11812 849 11.0 849 10.5 . - O p e n T o r q u e i< y p a s s S w i t c h Opent. 012 12998 -0 15.9 Open Limit Swatch Opens 016 13S95 -2.7 Motor Start CB . 6988 1059 Inrush Current Peak s7011 1476 -82.3 i on (Hear Middlei I 2 17216 -973 -4.2 Lost Closing Motion Runninij ReitCon <lition (Hear De.i n n' q : 18133 -1633 - 7.1 Closino Running Centti tion t He a r C r..:1 p 4 -6.6 4 C5 28405 -973 Close Turque la y pa s s s w a t e t. O p.e n s 30421 -1083 -6.1 Dise Notion Stops / Start or W ed y a . e* C7 --1192 -6.6 - Gli 30607 --321S7 -42.7 C1ose iornuo Sunt b O pe.: - <.. C :e ) J0764 C14 4S.2
-9PS 30770 -33177 lia 1 mum Ih c .:s t .ea1oe 30806 -36910 H.d C16 3 ->~ a n" c '3 3W' gg o ~ t' S i !
m . b .D
" "
- e..'..L %. ,%.. , ,,,y _.
g e
- 17. R
c -
. 01-2f-;i.M 03: T Pf1 FPOM l'TE E: ----- 70 51?Oa7 e iaa.2- P.es .. ....a..... * .:. + - .9. u 1~-
j - - a:
^
h...{a l Q 'g.gg e se g g S g $ $ ij@sJfA .
%:..u..u pW W...;:... d:..r We.g.?.e gQ M.* 'Z , ;
l Task.3" _[ i !- T&9: EU5i!."1 he .6 09
.p l .
! ygm - Y: lk e NIMIMTI0li OfILY s l i ODE.3Dtiot
./c-;;. : . 4( Qq f,;
v-
..:e! 1.li g.. . .t
( A, g
;: t .- 3 .. .
1
.Oq. iJ. . .., ...3 s wApe. .;
a =ww tes;r . ; g@#h. j ?r . WiHB
.. h% .s.cr*?{ w.w-W m. '
r (m/ . o 1, *: *- a.. ?
- l *' ..-l .
(.,.g . sus ssss sus
,- ns es ns y I I ' . u.e i i ,
1 []Igitt : n.u , A.
! \
I MlDE..' INU i - l f irrtut': 13.N.I f j k l < (ar F 3: = j a p 401.N e , 2 l : , : i * ' l
. I'.u.e s.> . ,k y ,,,3,,,,.
n.* .,- i , m ! . , . . '- 4. m.; , . 7 7
- n: ::.. ..:
n
*n t . . . F ;. ,. m :
i Tims in S-A 8.825 bliinti'bs hoge: Ett to -3685!5 lis. ; l
- - p- .
. g. .-o.:3 .;:, . , . s . c.
j. 2.500/2.500 . crqu:r Saidteh"Settino Open/C!ose...............: N 101t. Switett Rotor: Adjustment (Y/H)............: 0/ 0 i low -(gpsk Start /Ftnish........................: 0/ 0 i pstream Pressure ups:,). Start / Finish...........: 0/ 0 i cam 2trean Pressure. (pst) Start /Fintsh.........: i emeraliConsents:.: maintenance performed. Raised T/S E:.d ti::e tio get ! l S?lof t;.f: lube stem 4 tighten oke - estred thrust oston /. .T !abov Fillier.e min. OPER, design. Non: or:ng by passes during this test. l,
.>:; y l. Valve Actuator ! Ac tu a si '.*f o 4 -g.yilve Infornat nV Lon Actuator Type..: LIMI VCitage Tvpe: DC size...........: sne-1 voies.... ..: m m w:? FERMI.Z.,. ace.;;.:- '.14 .
Max. Thrust Rate: 4 19%;000 42 lbs 4mp catino..: 17.0
'800 .c ..Humber......: E'4150F001 Sert z.1 W.......: N o .a .
- 50.0
....... ....: GATE Order W........: 373E72-A S t a r *: 5 0.ced. s r.a.u e : .
kun Torque..: ,12. 0! i W...... ....: 19"l
;t4hrust..'.;J!+.2 5631 Ibs Worm Gear Teeth: 34 Hors e : f' owe r. : 1*33 tfom .~. .r. re ' VERTer .
Gear Ratio.....: 30.5 0007-1 Spring Pack N I
~ oc innut.. . . . :: HPCI RM P TURBINE -
Itse*natertal'. iameter.2.v r. :. 2.125; 9182 TY418- inches -- ; l 0 ,
. ad.s,rpe,r,s.{nch,t.4t , , . .;8n:dW: . z.uw .. .'
- soniRatioss4114.3?re.10E6.-psi . Sigt.al Conditioner Calibration Due Date OS/08/94 SetsarD.r.s WS.uSenstttvity..:,o .3. 746E-8883 t M'er P- g~v/v/lb ' -
+ . . ; .. 'l a A; m;s wr4. y ,.~ . .y;
- w. r......~.';.y
.m.u.f ; 4;.M.ijA e .~ . .
u,. . l ; y , .
.k rc ~ wg,("'. - ..-ke. .g e:. . s : ,;.: .. ' . . - ; M;--y . , ; . ,* 7+ ;
- a. ./ ,.:./..a:gi,3 >.n..
. .W . .*g. .::. +.
g.. ., a.. ....;.
.~ '
01-25-13 s gg: ;;M l FP0t1 rnE EF2 m TO 937c3777;a, , ,,. 06 l j . , ,, , , , , i .** - . . a.
" alt. 6102. M5fM ,i. . . . n .' x.:..... 'l .WQJ~ ~
h::.Qh:. 4.;lp 9 C . .xM : c.. ;NUv,
.: . ..::*+ h0W .:-
- -u. W: l
;'**i;. % aiS,.......
M P.. 4 .' ?. ;' *; - .. l + i~ 9 : M.s x....: . . :x , . . n. . ;. m... ..a p.&W.~Q,. s.e.uw.. p.;.a:
.?. .n. :- , . www..w. .. .. .m-
- " I IIIFORMATION.ONLY
)
Q&fk:.;:;y.
.G ? @M: yl !M :'
top E4sstest i .
-(
p bd: 1 ! l, 4 C . 3/B/94 ~ l I . ly . i
~3 s l :55 .
l ', l
^"
L-
- i. g
. .t:. .. .
7:. - 133. 5 7 W l l-jM _ ! l I E 2 3. -
- ( ..= !>'l IMl t
f i ll
. .l . l i ; -. . .q -
- i- 'r !
(NJ M ^ d -_ -' g gase ... i.: l , i Force >;= :-E5! i:- j g) m j- - : - . 4 t 1U : .
. .. .:.. . i;w. . , . LEM.u.
k.. 1.r=.- ' I
.,... , .- ., . t -
j r*. i.Li
;] c ,1 i
Y-fXPfB Ori i T*me in Seconds 1.lEB l
- h. .e .- .E. Q . :.T.,u. . .'.. :.. .
e {5 ?. (. Q .?I k... f.;S..$ i T::5..s. w. . - n y .:d, n .:.,: . . Valve Actuator i Act
.v Actuator Type..: LIMI Voltige i 6?4 . .. 9 a: n* EIn format' ion f .N:alv w Plant s. FERNU-4,-Nff'a i: * ..
Size...........: SMB-1 Max Thrust Rate: 195642 45000 lbs volts....I Amp rato
.:e Unit.
N""an .Humber. s 8 J. ;.4' ... . Y.. E4150F991 2;.fTE:: :.\qi .f.. Serial N........: N.......: Nos. i seet ! yJe. . ..& . .:. 4 s. s GATE Order 373272-4 Start toi Run Torgs j
+ 1. i"llze..;.........:.19" Worm Gear Teeth: 34 'arget ThrustJ...: 75631 lbs Gear Ratto.....: 30.5 Horse) Pm !
5pring Pach N 0007-1 '
.s .i ^*.i l I
Jrientation...~.;ar'UERT' -r.W. HPCI RM O TURBIHE i k
*tg kat on. Rater ,DL'heetark-s f. lW.'s/ a A184LTY419 u.sh Estici. inchesi ' x *. .. 3. ;. .-- 'ho t M . voads;perebetts%44*99 Toad c pemA 7N.M w d.nf. C/".0' .. .
l !
! t w.44 Wan1 EcK3.' x: .10E6's pst's . -. : r Signal Conditioner Cals.bration Due; Dat 3 >
ks@d.c/IW:2.ttt.-?n::,'f.p%;-L' '. . '. . I
= % . d .~. '.-:;- 'l k ..
E e > u^#h.83 :WW. gqxM% 4ffir-l.;.Q,.g.. i "
. .-i . , ... f .. n,,,., -t a -, canyd;:e:.. . -a4.C'e* .,'a.; 'ij ';.' "- * **
J.Le
.e ,..:an: .u '~ " ..=1. ~5. L. %..7.'* L,,y *?i., * .,.'a*- ." ". *{.' ,^ .*'-r . . ,l 3 *.vy{
pN k k Y;UJ.D.J.i "th' ~.'.** w;;. b.4 ,,,.:.i. M "+ I .. L % h?%9Wh&q$&.- *$,v :R:si .w- c .
'$$NbN.b. h:.3. . . .;.. .
a m.s.m_:,...
.i
- 01-25-1996 cs
- :s=n ::cn r: ::: su c- --
;y.W23& %2E.5*N $Y b YYY -
rM. Y i ROST-TEST.EFAIRA253NDATA SHEECR25INGNONEOTATIPu-
"' - l M
g + n m~~ -M N 4 ;::. ?, i?' dW CU' a (S'.5~:N W !I9 S ".l ' [. ~~ 5 5 5 M M l 7'8): T
~ m d-u-5. n [~ d...$t?.T 4'Zr..i.~ W.S' f -.. .. e -
I l = ' . q M.N';VLWM*FN TYPE h0RIENT:~,~-';.A, .6,w m a 66,::pss:a..u m.. dN, , : t t . .-. I l 'if DE$r R* DON .c .-w.m l DESIGN.h M-0:d STATIC TEST . l DYNAMICTEST [ e u g mz nan s.wmm _ -w a :a - w a v w.w. > . -,. - a.- ...< a , & .'Lk,bl NQ:2. %9_H%e.'& C~5 .GQ:n v.N,?,vl . %. . : . .-
.,.\
Q
.n E Fo 9 A t FZ.'o$. W.m . . n .
!8 WRNO. me-mGBBS5EggBMBER D .4. W .9 5 EllEMEiEEEliiilii
- c. D 33 n ..*~ *vo p :..;
l h: 7HRUST CALC
- . '.Ew.xam M e,5 rW o9.r.M m e . sa a r = e -
zzygm o 7 MEDPCAlf
- Dc. -% B 5 .
TWh a*td'aussiipaussmo i3i
==a vo t iv e ev A 'wm l = = - ! =. *: r e .-e>" .~. . v a- .'
STEM MATEMAL.i L
- A 1 R ~Z. -
F4. ' 6 67.TY M o.
~
i ,5 ?. 5 0 $,n $$$W? \g. N Y %e r Qf m $ m $
-~ 5 Eh lI ? ? " [' $. . . 2, a.s wu , , m. v- : :-
g n.- .. .
= ux was otA. . g. ... z. , i 2. sv - ' =.=' w -: . . . . ,
! ~ 1.r.w.wmm:.mu.a. 4.n :.+ ==n :w .... . c A-z. .- 1rm..+e m m www.:m . na.g r.cm u. VEL
- IRAg w. w-..a.,.h3.. ,
y
.r *. g'd. 8. . . .1Sk,n. C. . . . ~"
- ;.=.;
t
,.955
[. l
. aaen,;,-A% ;n- t.n:..,::? a.n u~m' m r u ..- M . W * - !g . CSI-THRUST :-: P "C . _.m__ _ Tu "3'2 I t- 7 ,
, 5:.: MAXDAUM nlRUST L =- C . ~~ ' 'a 4. Q l o
- i .'-, AVE. RUNNING 4 .' . . .C--- - W=w- Z =; -- n m ~.g. r^.. . l % 5 \ .7,:. m . . ; :. . ~ G d "h__.ct j c:p. FLOW CUTOFF j r: Q.J "_ _G- _ .
s m.- , THRUST -: . - . . as<- r __ .= _ w - - - - -- I s CAL.iBhATION .n .g . ~g. /.e,s s.A w i l 'i W'/5 oo o
$ EXTR,iPOLNDON "J:wsg- -
5.t i OklFCE AREA .1. ~ \ 5"3 .M ., L~3'b:. w2 -- m 2 .. % :. t
-gr.. E '~ ~Ei C- G & rr_ E i ' E " . .j ymp(m rwNG)i u r,. l \ * * - '- -- '="==^^'^^^2 y" = w ='-
PRESSURE AT
" . . CtrmNGMEDP / O b['+-- ' N WM MNAEAM I i.Ib ?. M 57s. 9 % M o 41* . 5 %=Mi4 %& ik>h?i-: 3.H. :M jig.55'.ih?l}*%ve*.
ni T, S.O.'t'3. 6 CAIrULATEJN>L;
~ w.T. . w : re m . 1 4 W r, &,E s: - # 0 ;o 3 O. . 3. .... ~w% .aWih ; p. ,.3. ., . , . . .. ca = .w:.._ ,W. . ' MIN:Z_;6: ?.Y$5?$.'
- .2.e.
- 7.;,' a$$-rhjQ-0:
'f h .rrA v.;ed. '.=w:rhj-f 5*bhii$$ , ?$ ~~. ,
t M w s y:gsgg1 .Bh:rm WWRu sR.W.c.n.: 22 . - . ggsch.w ggi.'g.V:WG 'm, . msc;.g cAI.ci e d.W.. . ~ MIN.H.,.".0MAAXdq m E m M= Ww.9 2 p . 1,9a g m.a,g .n - [OiW$u.?5or:~ 7w.. . . . . . .
.s. f. :,:g.g.,
y .i
- @f.Me_Pl!.1grf3,,.e,;g'.y ; . gout sa. =:3<.,=MW. e.o !y- ix -3,-;g .W .~'
- h. . . .-m .-
d PACYING1 DAD i' ~ ~-- i * - ;;- I '? .5~ w' M
$,i ^ -- _ " .~ _'_**. " - C4. : ,
y * - - * - %m %= ~ , .-. - 4 -~' MIN REQ'D -: wa W "i 2 f W!i: 7Wutjg'y": AT %%2ES-- ~ - ~$ 9.O L N..'..C,.
-a m, _ . _ _ _ _ _--- . . - . . ~/. ..-.' ' 24~-A
y. _ . . . . . , , , , , . ..,, ,g, ,4,, pc. m -+ ~L 4 s ll/Fogjpygyg, Page 37;of 41, lg ?
' ,{ ' sj
(
** VALVE DWG# SIZE TYPE STEM MTR. O A R. LEAD STR MEAN MEAN RE'.2LSTR._ ,i l $
PlS OP. TIME '
~
o TRAV~ TIME CL . IO s
..... NUMBER - .* -. - _ . _ . _ _ _ _ _ _ . _ . . _ - - . _ . . _ _ _ . p) ,_g g g) _ pg g) _
g g 113 _l ';.l y 18 938 1.700 78 8 05 105 103 103 87 ; ,~.. j4
- 8- E1150F605A V15 2110 P1 1704 18 GA .
78 G , 05 105 104 104r 88 113 18 GA 18 938 1.700
. E1150F605B V15 2085 P1-1704 [i.d . .t ..
3 365 ' 46 Q., 0 5 29 27 9 23 23 33 g
"*** E1150F608 V8-3407 P12187 _ 20 GA 17 375 20 1.725 881j 1 61 5 54 3 54 1 45 63 ; !~ ' g -a.- E1150F611A V8-4613 P1 11142 20 GA 20 88 5 1 61 5 54 1 54 45 63_
V8-4614 P1 11M2 _20 GA _1 725 'C* 4 1 ,, . E1150F6118l 29 7 05 11 9 12 11 9 10 13 m
*** V8 2019 PI-1273 12 GA 11 5 3.440 's.
E2150F004A 05 11 9 12 2 12 10 13 m P1-1273 12 GA 11 5 3.440 29 7
. .. . i E2150F004B V8 2020 05 11 3 11 2 11 1 9 12 J d V8 2021 P1-158 12 GA 11 5 3.330 27 6 q E2150F005A 8 12 ! y P 1-158 12 GA 11 5 3.405 27 6 05 11 2 11 ,10 5 w- E2150F0058 V8 202L 025 56 8 13 9 11 17 pj E2150F015A V8-200 P 1-932 10 GL 5'7fP5 1.700 115_ f 4_ '
115 0 25 56 8 16 .! 16 2 13 19 E2150F0150 V8 2034 P1932 10 GL 17f3-tr 1 700 14 9 12 2 18 L .. E2150F031A 98 4633 Pl.1123 3 GA 3 625 1.700 52 0 29 23 3 15 2 15 2 12 18 f GA 3 625 1.700 52 0 29 23 3 15 4 g
,g E2150F0318 V8-2032 P1 1123 3 05 51 48 3 48 4 41 56 E2150F036A V8 2007 P1 133 20 GA 20 625 1 700 '35 20625 1.700 35 , 05 51 49 5 49 7 42 ~ 58 i E2150F036B V8 2003 P1 133 20 GA '
10 GA 9.375 1.900 30 4 -05 18 14 4 14 3 12 17
' E4150F001 V17 2022 P1-943 I i-j 9
4 34 9 05 11 5 11 2 11 3 14 "i E4150F002 V17-2020 P1 152 10 GA 9.375 3 405 10 GA 9.375 1900 19 2 05 11 4 9 38 9 17 6 12 6 E4150F003 V17 2021 P1 3348 h 17 5 05 18 16 4 16 5 13 19 E4150F004 vfl 2191 P 1 134ft0 16 GA 16 25 1.900 va 2i94
~
i't 15HY ~1 T Ed~ 12625 1.900 22 3 ~ Oi ~178 ~13 3' '1H 11 16 ! E4150F006 13 20 V8 2193 P1 130 14 GA 12 625 1.900 25 7 0$ 20 5~ 16 4 16 9 e E4150F007 1 900 123 0 25 124 105 106 89 123 'l GL 8 10
-l E4150F008 V8 2198 ' P1-875 47 1.900 78 8 -05 154 1 40 8 . 40 6 34 -~-d-~ ' E4150F011 - V8:2200' P1-941 10 GA' -10 875 io 3 375 1.900 16 6 02 8 53 8 75 8 55 6 to E4150F012 V821% P t.13479 4 GL ,i .133 94 3 92 8 78 104 71 b i- 16- GL-- - . 15 1.900 _.140 _0 25 V112006- P1-5055 J .j ' I ~9 E4160F021 --
22 6 19 27 2 GL 1 36 100 0 17 25 8 22 8 E4150F022 V112008 P1 -5120 1_.900 15 6 13 18 V8 2204 P1-13481 16 GA 16 25 1.900 17 5 05 18 15 4 E4150FO41 E4150fD42 V8 2202 PI-13481 18 GA 16 25 1.900 17 5 05 18 14 9 15 3 12 18- 'P] $* 1,900 :102 0 17 26 3 24 7 24 20 29 seg E4150F059 V8 2216 P1 12 a6 2 GL 1 36 Calc , clot-60005 ID200V w l tltkn, n 1% f, ofy :{ f*
ci-II-:ss at:m wm ire ,_ mg - - - - - TO 3r7a37 3444 3- P.07
- VIU E' .
,p;. * = . .
wie clo2-t4cWRIc l V'pj;,y.
- p. ;. ~ .G@*. ' f. j: ' 1' -
Tag: 1415151181 Mo01,2,Pqej7cC9
.iTd :1 "} .
1
; . E.58 c.%.* ' ' %. ,6 . . :. .... . ...:.. . .
l .. 5k. .. w$. $... .: i.&}$'$$ o m n .:.:.y:w:.W o a n . W--u.m.
... .: u;,,: . n.:s x l.
me.- u....
-m . 2:. -p. . , .:-n . !.,/
r
."I .1.g. M cc.-:if f.'8 7: 'W "
j . ' ' M>: / ..,
'~
i
; h V l . . )-
(c,.Fh?:
.r,yeURE.b - g
- - =6 ; l l '. l,.( N olts M ; .
> a - . , . :
- + ,e,,.. ': .o '
t .I
..t*-.5.e. .,.s . . . ;
F. ?,. 4, i ; -
- v l y I rsg
- 8.514 l.~
'9 .i IIT. Se=s. : 3.7%H!!!!3 p.M!b~ 7, l
fleter gi : 6.701 , d l . , l 18tc = 451BB ns .. i ; i i '.Y - J 6,. l 4 a a
>..I 6 a i a E ..A : 8.999 3 .1 . .
8 . 4
- - I!. : se ;9 e
W - 1. O. l .seeems .seen. , l d' Force (Iks) .
.]'
i i- I
.l, .t..- .,-.. . ; I .
i. , .'. I i C-Clamp Calibratqr C19 43 - l Calibration Libration.Devicte Device Serial Huscer. . . . . . . : 12/01/93 Cal Date............: libration DeV1 e Sensitivity.........: 0.41%8 ov/w/uin aseter................: 114.266 1 .'f5 5 i n
- .-i . ffective Stem D1 son lasticity / Ratto.............: TCF = 1.034 X 10E6 :91 :
- crque Correc ton eFactor...............: Force Sensitivity. . . : 0.00237 pv/v/15 . .( ...C4113tation Delvic J
j dr '. ' Mtuat i D w votf.*: ' . . Valve Actuator Vol tag e.i Type j .}p* v.. ,914 . 4~:;*V ant:; ve' Ir formation Actuator Type..: t.1 MI , Volts.. ....
- I Size...........
- SMB-1 .
- 96Vnit.:.2 Mas Thrust Rate: 1945000 642 lbs- Amp racin ..
Hom. S age . . ! Serial W.......:
.H( Tc . Hunner. .GA .. i.. E l E4 50F001
- Start torque 4 3 ........!.... Order N........: 37 272-A . Run Torttue..l
- r e.. .
- ryet: b.......i 18"ust.r.. 25631 ;.; lbs Worm Gear Teeth: 34 . .
4
- ear Ratio.....: 38.5 i: Horse Peer.(
1entation...:.s.3 0 RT. pring Pack N 0007-1 . i' av. ation. . .r. .l. . t JHP I RM ) TURBINE , se: Material.l.. -) A18 'TY410 5 inches
; l l ;d"O
- tencDiameter.l.. . :
reads:per nens.t . . . . . toadsc evi r ::N . , . 4;3:x'18E6 psi 4 Pois <R tio. ials.or.42c :",.. . Signal Conditioner Calibratio,n Due Da; e et TESE t * , 5 M4 #:W f s ;-i . . t
. . f. Mt t.,.y , d .. , .
- )
E k"Ai,M::} .*W YI.k.w:.c5.$. ;.i.@ . :.d.:.~ ~ . I
'92M .'.'kl ,'.
w- $
, . , _ ~'
1 x:: ,^.{ ,Fg,s,s {. . . .. ., .- s. . j S. wm ~' YEP- ..Y * .'
- I cl.ht, .}}