WALK.ER DEPARTMENT OF MECHANICAL ENGINEERING Nuclear Engineering Teaching Laboratory -

Pickle Research Campus R-9000

  • 512-232-5380
  • FAX 512-471-4589 nuclear.engr.utexas.edu
  • wcharlton@austin.utexas.edu ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Geoffrey Wertz, P.E.

Non-Power Production and Utilization Facility Licensing Branch Division of Advance Reactors and Non-Power Utilization Nuclear Reactor Regulation April 16, 2020

SUBJECT:

Docket No. 50°602, Facility Operating License R-129 - Revised Submission ofNeutronic and Thermal Hydraulic Analysis for the University of Texas at Austin Research Reactor

REFERENCE:

October 18, 2018 letter: University-of Texas at Austin - Summary of Site Visit and Request for Schedule for Completion of the Reactor Analyses RE: Renewal of Facility Operating License No.

R-129 for The University of Texas at Austin Research Reactor (EPID NO. L-2017-RNW -0032)

Sir:

Docket No. 50-602, Facility Operating License R-129 - Submission ofNeutronic and Thermal Hydraulic Analysis for the University of Texas at Austin Research Reactor (March 31, 2020)

A technical error was identified in a review of the March 31, 2020 submission. The error has been corrected and is attached; please replace the March 31 submission with the attached material. If you have any questions, Rlease contact me at 512-232-5373 or whaley@mail.utexas.edu.

/".......

//

'}

~~

P. M. Whaley I

I declare under penalty of perjury that the foregoing is true and correct.

W. S. Charlton ATT:

(1)

Analysis of the Neutronic Behavior of the Nuclear Engineering Teaching Laboratory at the University of Texas (2)

Thermal Hydraulic Analysis of the University of Texas (UT) TRI GA Reactor