ML19025A079
ML19025A079 | |
Person / Time | |
---|---|
Site: | University of Texas at Austin |
Issue date: | 01/17/2019 |
From: | Whaley P University of Texas at Austin |
To: | Geoffrey Wertz Document Control Desk, Research and Test Reactors Licensing Projects Branch |
References | |
EPID L-2017-RNW-0032 | |
Download: ML19025A079 (16) | |
Text
COll.EGE OF ENGINEERING THE UNIVERSITY OF TEXAS AT AUSTIN Department ofMechanical Engineering* 1 University Stati011 C2200 *A11Jtin, Texas 78712-0292 Telephone(512)47l-1131 FAX (512)471-8727 01/17/2019 ATTN: Document Control Desk Nuclear Regulatory Commission Washington, DC 20555-0001 Geoffrey A. Wertz Project Manager U.S. Nuclear Regulatory Commission Research and Test Reactor Licensing .Branch
SUBJECT:
Docket No. 50-602, Revision to 09/24/2018 letter (Docket No. 50-602, Facility Operating License Response to 07/26/2018 Request for Additional Information for Proposed Operator Requalification Program)
REFERENCE:
- 1. Docket No. 50-602, Request for Additional Information Re: Operator Requalification Program Review for the Renewal of Operating License No. R-29 for the University of Texas at Austin Research Reactor (EPID No. L-2017-RNW-0032)
- 2. Docket No. 50-602, Facility Operating License Response to 07/26/2018 Request for Additional Information for Proposed Operator Requalification Program (09/24/2018)
- 3. Docket No. 50-602, Facility Operating License No. 50-602, Revision to Previous Response to 07/26/2018 Request for Additional Information for Proposed Operator Requalification Program (11/19/2018)
Sir:
We respectfully withdraw (1) reference 3 (RAI response of 11/19/2018), and (2) the proposed Operator Requalification Program, and submit this RAI response and a revised, proposed Operator Requalification Program dated January 17, 2019 as enclosed. This revision incorporates responses to Request for Additional Information (items 51, 52, and 53),
renumbering within the revised sections, and minor grammatical/editorial changes from the previously submitted Operator Requalification Program.
In response to RAI 51, as previously provided, at least five of the 13 possible items identified (as applicable to the annual operating test) will be included in the annual operating test. (The complete response is in the 09/24/2018 letter, "Docket No. 50-602, Facility Operating License NO. R-29, Response to 07/26/2018 Request for Additional Information for Proposed Operator Requalification Program").
In response to RAI 52, responsibility for personnel administering tests and exams will be assigned by the Director or Associate Director (Level 2 personnel) and personnel administering examinations and tests receive a waiver from the test or examination in accordance with the fil)Z b jJf._/(
guidance of ANSI/ANS-15.4. The NRC staff concern that a licensed operator could be indefinitely exempt from examinations and tests is addressed by including statements that "Personnel administering the {/biennial comprehensive written examinations/annual operating test}: ... Shall not administer sequential {examinations/tests} while participating in the operator requalification program."
In response to RAI 53, as previously noted, the citation does not apply, therefore no change is needed. (The complete response is in the 09/24/2018 letter, "Docket No. 50-602, Facility Operating License NO. R-29, Response to 07/26/2018 Request for Additional Information for Proposed Operator Requalification Program").
If there are any questions please feel free to contact P. M. Whaley at whaley@mail.utexas.edu or 512 232 5374.
Sincerely, P. ~:,.Whale~) , _
c:3i-...,__
-;Z,. ______ -~
.{J. --t:__ 0 ~
I declare under pen,7 y of perjury that the foregoing is true and correct.
W. S. Charlton
(
Enclosure:
Operator Requalification Program The University o Texas TRIGA Mark II Nuclear Reactor Facility, License R-129 Docket 50-602
- OPERAT OR REQUALIFICATION PROGR AM The University of Texas at Austin TRIGA Mark II Nuclear Reactor Facility TS License R-129 Docket 50-602 17 January 2019 Nuclear Engineering Teaching Laboratory 10100 Burnet Rd., Building 159 Austin, Texas 78758
Table of Contents
- 1. Introduction 2
- 2. Schedule 2
- 3. Lectures 2
- 4. On-the-Job Training 3 4.1 Control manipulations 3 4.2 Procedures and principles of operation
- 5 4.3 Facility Changes 5 4.4 Emergency procedures 6
- 5. Evaluation 6 5.1 Comprehensive requalification written examinations* 7 5.2 Annual operating tests 8
- 6. Conditions of Licenses 10 6.1 Participation in Requalification Program 10 6.2 Operational Proficiency 10 6.3 Capabilities for safe and competent execution oflicensed duties 11 6.4 Felony Convictions 13
- 7. Records 13 7.1 Requalification program records 13 7.2 Operator and senior operator licenses 13 7.3 Operating logs 14 2
- 1. Introduction Licensed operators and senior operators at The University of Texas at Austin are required to participate in the Operator Requalification Program. The Operator Requalification Program requires each operator and senior operator participate in a requalification plan implementing periodic requirements. The requalification plan includes scheduled training activities such as lectures, requalification written examinations, operating tests, and on-the-job training requirements.
In accordance with 10CFR55 (§ 55.59, Requalification requirements), the Operator Requalification Program addresses:
- Schedule
- Lectures
- On-the-Job Training
- Evaluation
- Records The Operator Requalification Program also addresses selected items from§ 55.53 (Conditions of Licenses) related to maintenance of operator and senior operator licenses.
Each operator requalification plan is conducted continuously using a 2-year (24 month) cycl~.
For purposes of the Operator Requalification Program, "biennial" or "biennially" means every two years, not to exceed 30 months and "annual" or "annually" means every 12 months not to exceed 18 months. The maximum period for an annual requirement within the Operat9r Requalification Program is established to allow .flexibility in coordinating the requalification program with academic schedules.
- 2. Schedule Each operator requalification plan shall be conducted for a continuous period not to exceed two years and shall be promptly and continuously followed on conclusion by successive operator requalification plans.
- 3. Lectures Preplanned*lectures shall be conducted on a regular and continuing basis when operator and senior operator written examinations or facility operating experience indicate that emphasis in scope and depth of coverage is needed. Where the evaluation of an individual operator's or
- senior operator's knowledge is adequate and performance is proficient, participation in lectures is not required. As described in§ 55.59(c).2 (Lectures), the following subjects are addressed:
- Theory and principles of operation, 3
- General and specific plant operating characteristics,
- Plant instrumentation and control systems,
- Plant protection systems,
- Engineered safety systems (as applicable),
- Normal, abnormal, and emergency operating procedures,
- Radiation control and safety,
- Technical specifications,
- Applicable portipns of title 10, chapter I, Code of Federal Regulations, and
- Emergent issues identified by facility management.
- 4. On-the-Job Training I
On the job training addresses training activities related to:
- Control manipulations,
- Procedures and principles of operation,
- Knowledge of changes to the facility, and
- Emergency procedures.
4.1 Control manipulations Each licensed operator and each licensed senior operator is required to manipulate the controls for specific plant evolutions described in § 55.59. Senior operator licensees are credited* with completion of control manipulations if they* direct the manipulations as they are performed.
Simulation is acceptable for control manipulations related to_ emergency or abnormal condition, and actual manipulation of the plant controls is not.required.
- These rpanipulations may b~ accomplished as part of the Annual Operating Test of section 5.2, in group training sessions conducted as lectures incorporating simulations, or independently; therefore, these control manipulations may be documented as evaluation of the Annual Opei:ating Test, training lecture records, or in console logs. Simulations that are not part of the Annual Operating Test should be documented with the operator or senior operator training records, and sh011ld include (1) the scenario, (2) a summary of simulated actions, and (3) a reference to the appli.cable procedures.
4
4.1.1 Manipulations required to be performed annually:
- Reactor startups to greater than 10 kW,
- Plant shutdown,
- Significant (2::: 10 percent) power changes in manual rod control (this may be integrated with a startup to greater than 10 kW),
- Loss of coolant, including Loss of pool water Cooling system failures
- Loss of instrument (and plant) air, and
- Loss of electrical power (or degraded power sources).
4.1.2 Manipulations required to be performed biennially:
- Loss of protective system channel.
- Control rod drops.
- Inability to drive control rods.
- Fuel cladding failure detected by high activity in pool coolant or continuous air monitor indications.
- Malfunction of an automatic control system that affects reactivity.
- Nuclear instrumentation failure.
4.2 Procedures and principles of operation Each licensed operator and senior operator shall demonstrate satisfactory understanding of the operation of the apparatus and mechanisms associated with control manipulations of this section, as documented in the biennial comprehensive written examination and/or the annual operating test.
4.3 Facility Changes To ensure that each licensed operator and senior operator is cognizant of facility design changes, procedure changes, and facility license changes, such changes will be communicated by the reactor manager to all licensed personnel as they occur.
5
4.4 Emergency procedures Each licensed operator and senior operator shall review the contents of all emergency procedures annually.
- 5. Evaluation Individual licensee knowledge and proficiency shall be evaluated based on the comprehensive ,
- written examination and operating tests. The results of testing will be used to determine if the operator or senior operator has an adequate and proficient level of knowledge and performance and identify weaknesses to be addressed in training as programmatic or emergent issues.
5.1 Biennial comprehensive requalification written examinations Comprehensive written examinations shall be given biennially to determine licensed operators' and senior operators' knowledge of subjects covered in the Operator Requalification Program, and to provide a basis for evaluating knowledge of emergency procedures. Examination questions will be based on the applicable sections of§ 55.41 (Written examination: Operators) and § 55.43 (Written examination: Senior operators) 5.1.1 Personnel administering the biennial Comprehensive written examinations:
- Are designated by the NETL Facility Director or Associate Director
- Receive a waiver from the written examination of operator requalification program, and
- Shall not administer sequential examinations while participating in the operator requalification program.
5.1.2 The comprehensive written examinations shall be:
- Graded on a scale from Oto 100%
- Based on questions derived from a representative sample of the following items (16 for operators, 21 for senior operators): *
(1) Fundamentals ofreactor theory, including fission process, neutron multiplication, source effects, control rod effects, criticality indications, reactivity coefficients, and poison effects.
(2) General qesign features of the core, including core structure, fuel elements, control rods, core instrumentation, and coolant flow.
6
(3) Mechanical components and design features of the reactor core and pool cooling system.
(4) Chill water cooling and auxiliary systems that affect the facility.
(5) Facility operating characteristics during steady state and transient conditions, causes and effects of temperature-based reactivity changes, and operating limitations and reasons for these operating characteristics.
(6) Design, components, and functions ofreactivity control mechanisms and instrumentation.
(7) Design, components, and functions of control and safety systems, including instrumentation, signals, interlocks, failure modes, and automatic and manual features.
(8) Components, capacity, and functions of emergency systems.
(9) Shielding, confinement, and confinement isolation design features.
(10) Administrative, normal, abnormal, and emergency operating prqcedures for the facility.
(11) Purpose and operation of radiation monitoring systems, including alarms and survey equipment.
(12) Radiological safety principles and procedures.
(13) Procedures and equipment available for handling and disposal of radioactive materials and effluents.
(14) Principles of heat transfer thermodynamics and fluid mechanics.
(15) (Senior operators only) Conditions and limitations in the facility license.
(16) (Senior operators only) Facility operating limitations in the technical specifications and their bases.
(17) (Senior operators only) Facility licensee procedures required to obtain authority for design and operating changes in the facility.
(18) (Senior operators only) Radiation hazards that may arise during normal and abnormal situations, including maintenance activities and various contamination conditions.
(19) (Senior operators only) Assessment of facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.
7
(20) (Senior operators only) Procedures and limitations involved in initial core loading, alterations in core configuration, and determination of various internal and external effects on core reactivity.
(21) (Senior operators only) Fuel handling facilities and procedures.
5.1.3 If an operator or senior operator scores less than 80% on the written examination:
(1) The person responsible for preparing and administering the test shall
- Identify performance weaknesses based on the subject areas in Section 3, and
- Prepare subject area examinations to evaluate if the weaknesses have been adequately remediated (2) The examinee shall attend lectures on the subject area identified (3) The examinee shall score at least 80% on the applicable subject.area examinations 5.1.4 If an operator or senior operator scores less than 70% on the comprehensive written or remedial subject area examination, the operator shall be relieved from licensed duties until the training and examination specified in 5.1.3 are complete.
5.2 Annual operating tests The annual operating test will include a systematic observation and evaluation of the performance and competency oflicensed operators and senior operators in UT TRI GA specific evolutions and control manipulations derived from 10CFR55.45 (Operating tests). Satisfactory completion of the operating test will demonstrate to the examiner, to the extent possible, the licensee's understanding of and the ability to perform the actions necessary to accomplish the selected plant evolutions and control manipulation.
5.2.1 Personnel administering the annual operating test:
- Are designated by the NETL Facility Director or Associate Director,
- Receive a waiver from the annual operating test of the operator requalification program, and
- Shall not administer sequential examinations while participating in the operator requalification program.
5.2.2 The annual operating test shall be
- Graded as Satisfactory (S) or Unsatisfactory (U) 8
- Based on a representative sample of at least five of the following 13 items:
(1) Performance of pre-startup procedures for the facility, including operating the controls associated with equipment that could affect reactivity.
(2) Manipulation of console controls as required to operate between shutdown and designated power levels.
(3) Identification of annunciators and c~ndition-indicating signals, including performance of appropriate remedial actions.
(4), Identification of instrumentation systems and the significance of instrument readings.
(5) Observation and safe control of operating behavior characteristics of the facility.
NOTE Simulation is acceptable for control manipulations related to emergency or abnormal condition, and actual manipulation of the
. plant controls is not required.
Successful completion of a simulation requires the licensee demonstrate understanding of the actions to be taken and the applicable procedures to be used.
(6) Performance of control manipulations required to obtain desired operating results during normal, abnormal, and emergency situations.
(7) Safe operation of pool cooling and chill water, and identification of how operation of these systems affects the facility.
(8) Safe operation of systems whose controls could affect reactivity or the release of radioactive materials to the environment.
(9) Demonstration or description of the use and function of radiation monitoring systems, including fixed radiation monitors and alarms; portable survey instruments, and personnel monitoring equipment.
(10) Demonstration of knowledge of significant radiation hazards, including permissible levels in excess of those authorized, and ability to perform other procedures to reduce excessive levels of radiation and to guard against personnel exposure.
9
(11) Demonstration of knowledge of the emergency plan, including, as appropriate, the operator's or senior operator's responsibility to decide whether the plan should be executed and the duties under the plan assigned.
(12) Demonstration of knowledge and ability as appropriate to the operator or senior operator position to assume the responsibilities associated with the safe operation of the reactor.
(13) Demonstration of the operator's or senior operator's ability to function in such a way that procedures are adhered to and that the limitations in the facility operating license and amendments are not violated.
5.2.3 If the operator has performed at an unsatisfactory level, the operator will be relieved from licensed duties until the following items are complete:
- Development of a Remedial Training Program, proposed by the reactor manager and approved by the NETL Director or Associate Director,
- Completion of the approved Remedial Training Program, and
- Successful completion of an operating exam.
- 6. Conditions of Licenses The Operator Requalification Program includes specific requirements to maintain an operator or senior operator license such as the minimum time in performance of licensed duties, and assurance that the licensee is capable of safe and competent performance.
6.1 Participation in the requalification plan Each licensed operator or senior operator shall participate in the Operator Requalification Program, including the requalification plan and other activities required to maintain an operator or senior operator license.
6.1.1 If an operator or senior operator does not participate in the requalification plan, the operator or senior operator license will be suspended. .
6.1.2 A suspended license may be reinstated on successful completion of all current requalification plan requirements.
6.1.3 A license suspended for two years for failure to participate in the requalification plan will 1 be terminated.
10
6.2 Operational Proficiency
\
Each licensed operator or senior operator shall maintain operational proficiency as follows:
6.2.1 Every calendar quarter, each licensed operator or senior operator shall be the operator at the controls while the reactor is operating for at least 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
6.2.2 If a licensed operator or senior operator has not operated for at least 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> in the previous calendar quarter:
- The operator or senior operator license will be suspended, except that
- The operator or senior operator shall operate the reactor under s1J,pervision of a licensed operator or senior operator for at least 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> prior to operating without superv1s1on.
NOTE Since the intent of this requirement is to assure the operator or senior
\
operator has sufficient operating experience for safe operation, the supervision may be performed by a licensed operator or senior operator.
- Prior to releasing the suspension, the reactor manager shall verify that the qualifications and status of the licensee are current and valid.
6.2.3 In the event that facility conditions such as an extended shutdown prevent licensed operators and senior operators from completing at least 4-hours of operation within a quarter, prior to resumption of normal licensed activities all operators and senior operators shall complete a special Facility Retraining Program:
- The Facility Retraining Program shall be approved by the Reactor Oversight Committee
- The Facility Retraining Program shall include (as a minimum):
(1) Observation of subcritical behavior, (2) Approach to critical using subcritical multiplication to predict critical control rod positions, (3) Operation at power levels greater than 1 kW, and (4) A minimum of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of operations with at least one hour shall be as operator at the controls (up to one hour may be as an observer) 11
6.3 Capabilities for safe and competent execution of licensed duties All operators and senior operators will maintain the ability to safely and competently perform licensed duties, including:
6.3 .1 A medical examination every two years; 6.3.2 If the operator or senior operator does not have a medical examination prior to (and no earlier than 60 days prior to) the anniversary of the effective date of the license, the reactor manager, Associate Director or Director shall:
(1) Notify the USNRC, and (2) Suspend the operator or senior operator from licensed activities until such time as the medical examination is complete and indicates the operator or senior operator is medically qualified 6.3.2 Consumption or ingestion of alcoholic beverages within the reactor bay or designated temporary controlled access areas is prohibited; if an operator or senior operator is found to be consuming or ingesting alcoholic beverages within these areas then the reactor manager, Associate Director or Director shall:
(1) Notify the USNRC, and (2) Suspend the operator or senior operator from licensed activities pending investigation and disposition of any required legal/judicial actions.
6.3 .3. Use, possession, or sales of any illegal drugs is prohibited; if an operator or senior operator is found to have used, possessed or sold any illegal drugs while licensed to operate the facility then the reactor manager, Associate Director or the Director shall (1) Notify the USNRC, and (2) Suspend the operator or senior operator from licensed activities pending investigation and disposition of any required legal/judicial actions.
6.3.4 When the consumption or ingestion of alcohol, prescription medicines or drugs, and over the counter medicines or drugs has the potential to adversely affect an operator or senior operator in the performance of licensed duties,
- The affected operator or senior operator shall notify the reactor manager, associate director, and/or the director.
- The reactor manager, associate director, and/or the director shall evaluate whether the abilities of the operator or senior operator have been affected to the exten\ that the ability to safely and competently perform licensed duties is impacted.
12
NOTE Although a formal medical evaluation may be requested and performed at the discretion of the reactor manager, Associate Director, or Director "the potential to adversely affect" is intended to be an informal and conservative assessment. Medical side effects should be reviewed along with observation of changes to the operator's or senior operator's general demeanor, bearing, alertness, and mental acuity.
Operation under the influence" of the substances listed in 6.3.4 has the potential to adversely affect performance and can be verified by a confirmed test results exceeding the lower of the cutoff levels for drugs or alcohol contained in subparts E, F, and G of 10CFR26.
- If performance is a~versely affected, the reactor manager, associate director, or the director shall relieve or suspend the operator or senior operator until the ability to safely and competently perform licensed duties is no longer compromised.
6.4 Felony Convictions 6.4.1 If an operator or senior operator is convicted of a felony while licensed to operate the facility, the licensee shall notify:
- The reactor manager, associate director, and/or the director immediately, and
- The USNRC within 30 days 6.4.2 The Director shall suspend the operator or senior operator from licensed activities pending evaluation that the operator or senior operator is still capable of successfully completing a background check for unescorted access and access to safeguards information.
- 7. Records Each record must be legible throughout the retention period in 7.2. The record may be the original or a reproduced copy or a microform provided that the copy or microform is authenticated by authorized personnel and that the microform is capable of producing a clear copy throughout the required retention period.
7.1 Requalification program records All requalification plan records shall be maintained for the current and previous cycle biennial requalification plan, including:
13
- Documented participation of each licensed operator and senior operator in the requalification plan,
- Copies of written examinations administered, the answers given by the licensee, and the results of evaluations and documentation of operating tests, and
- Any additional training administered in areas in which an operator or senior operator has exhibited deficiencies.
7.2 Operator and senio.r operator licenses Copies of active reactor operator and senior reactor operator licenses are maintained in the control room.
7 .3 Operating logs The operating logs contain records of reactor operator/senior reactor operator at the controls, including reactivity manipulations such as startup, shutdown and power changes as well as start and stop times for operators at the controls. Retention of operating logs is identified in Technical Specifications.
14