Text

~~~~

App,,,a ero w u s No.

$e Vogt;e Electric Generating Plant 91403-C 7

/

NUCLEAR OPERATIONS

-c g,g,,,n g,,

O M#

  • '8 '" " **'

' " ~ '

FOR INFORMATION ON

  • 1'h SITE EVACUATION 1.0 PURPOSE The purpose of this procedure is to provide instructions for the early dismissal or evacuation of non-essential personnel including visitors at VEGP in l

the event of an emergency.

q 2.0 RESPONSIBILITIES 2.1 The Emergency-Director shall be responsible for determining the need for early dismissal or evacuation and selecting evacuation routes.

2.2 The Security Coordinator shall be responsible for conducting the evacuation and directing the Security

.~

Force to assist in various stages of the evacuation.

2.3

-The HP Supervisor or Dose Assessment Manager will provide HP support for monitoring and decontamination at the selected offsite relocation center..

l 3.0 PREREQUISITES The Emergenc Director has determined that conditions warrant-earl dismissal or evacuation of-all non-essentia personnel.

4.0 PRECAUTIONS The evacuation should be conducted in an orderly fashion so as to prevent personnel injury.

5.0 PROCEDURE 5.1 EMERGENCY DIRECTOR 5.1.1 The Emergency Director shall order evacuation of non-essential personnel (if feasible) whenever a. Site Area or General Emergency is declared.

l l^ 0 G

9202200452 920116 PDR MOOCK 05000424 4

G PDR mes om I

-..c.m.

....--.-.....r.

-,.-..-,_-,_~.m

-m_.

[Gocrev8L n HLv@oN Pio't no y

91403-0 4

2 of 9 i,

5.1.2 The Emergency Director may also order a specified area dhh{

nyacuation under the following conditions:

5.1.2.1 It is determined by actual observation or by calculation that personnel will receive 100 Mrem, or a dose rate of 2.5 Mem/hr in a normally non-radiologically controlled building.

5.1.2.2 It is determined that there is a threat to the health I

and safety to onsite personnel exists.

5.1.2.3 There is no reason to retain these personnel in the area.

5,1.3 The Emergency Director has the option to (1) send personnel. home from work early before there is a danger of radiation exposure or, (2) evacuate personnel to an offsite relocacion center for monitoring, if a release has occurred and contamination is detected or suspected.

5.1.4 Early releases from work shall be initiated and conducted per Subsection 5.7 of this procedure.

5.1.5 The Emergency Director shall confer with the HP r')

Supervisor (or Dose Assessment Manager if EOF is (y

activated) on wind direction and other factors which will influence the choice of whether to evacuate to the crimary or alternate offsite relocation center.

The Imergency Director shall then decide which relocation center shall be utilized.

5.1.6 The Emergency Director shall notify the Security Coordinator (or Supervisor Nuclear Security - SNS if l

EOF is not activated) and inform him of the impending evacuation.

This will allow Security time to prepare and initiate its evacuation activities.

NOTE If this is a drill, the message should be preceded and followed by the statement:

"THIS IS A DRILL "

5.1.7 The Emergency Director shall make the following announcement over the plant PA system:

" ATTENTION ALL PERSONNEL ATTENTION ALL PERSONNEL

- NON-ESSENTIAL PERSONNEL ARE ORDERED TO EVACUATE.

(~]

FOLLOW THE DIRECTIONS OF SECURITY TO ENTER YOUR

(_/

CAR OR DESIGNATED BUS.

REPORT TO THE RELOCATION CENTER AT (relocation center).

REMAIN THERE UNTIL CLEARED TO LEAVE."

$344k

" ~ ' * *

  • PRoCEDUAE No nEyestoy p,gg g 91403-C 4

3 of 9 j

i 5.1.8 The Emergency Director shall direct Security (SNS) to e

O activate the site siren, and make an announcement on 4

the site siren PA system in accordance with EPIP 91704-C, " Actions For Security During A Radiological Emergency".

5.1.9 The Emergency Director shall notify the Security Coordinator (or SNS if EOF not activated) so that notification of personnel outside the Protected Area may be performed in accordance with "rocedure 91704-C,

" Actions for Security during a Radiological Emergency".

4 5.1.10 The Emergency Director shall receive periodic reports from the Security Coordinator (or SNS) on the progress i

of the evacuation.

5.2 SECURITY COORDINATOR (OR SUPERVISOR NUCLEAR SECURITY

- (SNS) IF EOF IS NOT ACTIVATED) 1 5.2.1 Upon declaration of an Alert, designate one of the Security Officers to be Evacuation Leader (Subsection 5.4) and dis?atch him to the relocation center along with Health ?hysics support.

This will allow setup prior to evacuees arriving.

5.2.2 Upon notification of the impending evacuation from the O

Emergency Director, the Security Coordinator shall perform the following actions:

5.2.1.1 Designate one of the Security Officers to be Evacuation Leader (Suboection 5.4) and dispatch him to the relocation center if not already performed at an Alert.

5.2.1.2 Dispatch Security Officers to plant gates and traffic control points for traffic control.

5.2.1.3 Contact the HP Supervisor or Dose Assessment Manager to ensure that sufficient Health Physica sup3 ort (at least two individuals) has been dispatched to ele relocation center to conduct radiation monitoring and decontamination.

5.2.1.4 Contact the relocation center and inform them of the impending evacuation.

5.2.1.5 Perform protected area accountability"per Procedure 91401-C, " Assembly and Accountability if not already completed.

5.2.1.6 Check with the HP Supervisor or Dose Assessment Manager concerning radiological conditions prior to dispatching Security Officers to check owner controlled areas to O

assure that all non-essential personnel have been evacuated.

?

7c3 45

._ ~_

PRoCEDUAE No.

REVISloN PAQi'No 91403-C 4

4 of 9 5.3 HEALTH PHYSICS 5.3.1 Designated Health Physics staff shall be dispatched to the relocation center at an Alert to allow setup of the center prior to evacuees arriving.

5.3.2 After informing the Evacuation Leader of their arrival at the offsite relocation center, the Health Physics staff shall establish a monitoring point and if necessary, a decontamination point in accordance with Procedure 91306-C, " Contamination Monitoring and Decontamination".

5.4 EVACUATION LEADER U)on his appointment by the SNS, the Evacuation Leader I

siall report to the relocation center and implement the Evacuation Leader Checklist.

5.5 EVACUATING PERSONNEL Upon activation of the evacuation notiiication, personnel shall proceed to the offsite relocation center, taking directions from Security Officers.

5.6 0FFSITE RELOCATION CENTER AND EVACUATION ROUTES 5.6.1 The Emergency Director shall order evacuation to the VEGP Recreation Area, the primary offsite relocation center, if radiological conditions allow its use.

The evacuation route shall be the main plant access road, see Figure 3.

5.6.2 The alternate offsite relocation center is located at Plant Wilson.

The evacuation route shall be the visitors center access road, see Figure 3.

5.7 EARLY DISMISSAL 5.7.1 The Emergency Director may determine that it is desirable to send persons home before there is a danger of radiation exposure.

5.7.2 The Emergency Director shall direct an early dismissal in accordancu with 91102-C, " Duties Of The Emergency Director".

4 5.8

-POST-EVACUATION CONDITIONS 5.8.1 The Security Coordinator shall assure that all personnel have been evacuated, as appropriate, and shall brief the Emergency Director.

roun

_ _ __._. _.._ _._,_ _ m. _.

_,__..___..___.m.__.___.~_.___.

e PHoCEDUXENo.

REVIStoN PAGE No 91403-C 4

5 of 9

,v O

5.8.2 The Security' Coordinator shall collect all accountability forms, relocation center monitoring data and other evacuation records.

5.8.3 The Security coordinator shall ensure that access l

control to the protected area is provided by the Security Department during emergency conditions.

Access will be granted to Emergency Response Personnel and NRC Personnel.

6.0 REFERENCES

6.1 VEGP Emergency Plan 6.2 PROCEDURES 6.2.1 91102-C,

" Duties of The Emergency Director" l

6.2.2 91306-C,

" Contamination Monitoring And i

Decontamination" t

6.2.3 91401-C.

" Assembly And Accountability" 6.2.4 91704-C,

" Actions For Security During A Radiological Emergency"

()

6.3 NUREG-0654, FEMA-REP-1, Rev. 1. " Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants" i

END OF PROCEDURE TEXT O

m.o

~.,.

-s PROCEDU,.c No.

GEVI5 ION PAGE NO-91403-C 4

6 of 9 GROUP LOCATION MAP FOR

(~'

0FFSITE RELOCATION CENTER -

1

's.))

AT RECREATION _ AREA I

//

/

b..,_

//

r I

//

'll l'l

,-~~~

'y

,k s

/

ovenrtow rAmKiwo

'[

(f

/

AnoVNo Loor ANO ALoNG NORTH Slot f

g

/

or RoAo to Gait ANO west siot

/

//

i i

or noAo To roNo t

f I

,1 I

g m st

)

[ f j l f~~~~9 I

l ti If

\\

I l -Pw l

s-I s\\

l i

l I

g

',I l

\\

=;;

I

\\~~;~M,s;;jl4 l

l l/#

\\ts

~~~

J

[

/

p v

/

/

s

\\

/

g

  • Q

, /l

    • N j.

_=

g

/

f l'

j E

,,em.as 4 4

f f w

em. t I

// p maattenth

/f [/

VIHICLE SCAIEN ANo rARKING SE0tNS HE At I,

g

\\ @n.-

  • y',s t s g
  • \\g

\\ s W

g s s s

'g

\\

\\

s g

g g s N

g

\\o

, c,.

4 s

,r ~

5

O" Fi ure 1 S

8.

f i

No Livision p Ac t 46'""~~ ~"" "

91403-0 4

7 of 9 i'

GROUP LOCATION MAP FOR OF75T'ITRELOCATION CENTER-O ATPLANT WILSON o

r T

i t

ir

\\

E R

l u

o MElklAAY I

I 2 0e28 i;

it QEMOIut M

[

ll l

(

m,

A.,

e N,.

i i

m e

D000Er,en Asst,190 Pne AABIABA

/

l' l

l t

v m

.A 80R40seIIIS 11 i

t y

((

=y

=

. +

=

=

=

=

=

=

=

=

S.A,.

,sincep AmeA=4ae a fee Pet?

5 4

(.

(

Figure 2

'e

' casas l'

i p

0

=

O E

1

/ g.

g, 1

//

!!s 4

cu 3

O

\\

~

y\\

I I.

.s k

l 5

L

~

$ l

  1. p.

4 s

e

}'

O i

~

m.

PMociDW t No.

Levi $loN PAGE No 91403-C 4

9 of 9 v'

i Sheet 1 of 1 EVACUATION LEADER CHECKLIST POSITION FILLED BY: On shift Security Officer RESPONSIBILITY:

Supervise activities at the offsite

~

relocation center including monitoring and decontamination of evacuees.

INITIAL ACTIONS:

1.

Upon direction from the SNS, re, ort to the designated I

relocation center along with a Liealth Physics Technician, 2.

Assist the Health Physics Technician to establish a i

decontamination area as necessary.

SUBSEQUENT ACTIONS:

l.*

Provide periodic updates to the SNS (Security coordinator, I

EOF activated) via radio or telephone.

2.*

Direct arriving groups to specific locations (See Figures 1 & 2).

3.*

Supervise the monitoring and decontamination of evacuees.

4.

Request assistance from the SNS (Security Coordinator, EOF i

activated) if required.

r3

  • Continuing Activity V

rotan 1