e AFFENDIX A i
NOTICE OF VIDIATION l
Jersey Central Power and Light Company Madison Avenue at Punch Bowl Road Morristown, New Jersey 07960 Docket No. 50-219 License No. DPR-16 4
Based on the results of an NRC inspection conducted on November 17-21, l
i 1975, it appears that certain of your activities were not coeducted in full compliance with conditicas of your license as indicated below:
A.
Contrary to 10 CFR 50.59, " Changes, Tests and Experissets,"
i 10 CFR 50, Appendix B, Criterion V, " Instructions, Procedures and Drawings," the Operational Quality Assurance Plan, Section Y j
and reference Procedure No. 105, "Maint===are Repair and 1
l Modification control," and/or Procedure No. 2006 "Modificat3da, Neuroutine Maintenance and Repair," two (2) penetrations providing for cable runs servicing computer banks were drilled adjacent to I
the reactor control room and into the cable spreading room, a i
vital area. This work was completed without required design review and written safety evaluation or formalized work author-ization on or about November 1, 1975.
l This is an infraction.
1 B.
Contrary to Technical Specification 6.2.A.1 and 6.2.0 and Operating
' pg Procedure No. 304, Revision 0 issued January 22, 1975, Standby Liquid Control valve V-19-24 was observed on November 20, 1975 l
not locked as required and was in addition verified by the cog-nizant shift foreman to be in the open position whereas procedure
{
304 requires the referenced valve to be closed and locked.
We note that corrective action was taken in that the valve was restored to its proper position and locked, and a revised valve i
lineup checklist was completed November 20, 1975.
e i
This is an infraction.
4 k
4 4
t i
I a
9604220207 960213 PDR FOIA DEKOK95-258 PDR
j
.- 2--
i C.
Contrary to 10 CPR 50, Appendix B, Criterion 11 " Quality Assurance 3
Program," and Criterion V, " Instructions, Procedures and Drawings,"
the implementing provisions of the Oyster Creek Operational Quality 4
i - -
1 Assurance Plan,Section II, (Raference JCP41 letter to Division of Reactor Licensing dated May 2, 1974) and ANSI M45.2.3-1973 Section i'
3.2.3 "Pire Protection and Prevention," fire watches had not been specified during and immediately following welding operations.
l Additionally, procedures do not specifically address the usage and control of combustible materials or special work controls to be effected during welding, nor are provisions specified to provide i
portable or installed fire suppression equipment in work areas where welding or'other ignition processes are conducted.
This is an infraction.