Confirms Recent Verbal Communications Made by Licensee to AEC Staff Re Fuel Densification,Exxon Nuclear Fuel.Informs That Licensee Understanding Is That Particularly Conservative Restrictions on Operation Temporary
ML20107A674
Person / Time
Site: Oyster Creek
Issue date: 08/24/1973
From: Bartnoff S
JERSEY CENTRAL POWER & LIGHT CO.
To: Schemel R
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML18039A986 List: ... further results
References
FOIA-95-258 NUDOCS 9604150074
Download: ML20107A674 (2)


Text

.

y' Q;,3;

)

g r/:-

1 i

e.

y Jer'sey. Central Power :& L'igh t Company h

e.

p n

1

.:?

M Aolsot AVENUE AT PUNCH BOWL Ro Ao e MoRRISToWN. N.J. O

  • 539 8

E, RECEIVED

~

August 24,.1973 SEF4 1973

-1 e 3.. --n be ;r r ysr.

m a-Mr. Robert J. Schemel, Chief

'i eCu 8

Operating Rasctors Branch #1 60 e

    • '.G W

Directorate of Licensing Gt... g g United States Ator.ic Energy Comtr.ission Wnshington, D. C. 20545

)

REFERENCES:

(1) AEC letter from Mr. R. J. Schemel, July 16, 1973 (2) GE Topics) Report, NEDM-10755, Supplement 6 (3) JCPGL Co. letter from Mr. I. R. Finfrock, Jr. to Mr. 3. J. Schemel, August 15, 1973 (4) JCPGL Co. C,yster Crcek Nuc1 car Generating Station FCR No. 4 and Supplements L' car Mr. Schemel:

SUBJECT:

Fuel Densification, EXXON Nuclear Fuci Th - "" - i_c to confim recent verbal comunicatiens tyde by j

Jersey Central Powei G Light Ccmpany to the AEC Staff.

The postulated LOCA analysis has been perfomed, as ree,uested by j

the AEC Staff in c necting held on August 22, 1973 cnd in subscqvent telephone conversstions, to detemine the applicable limit on maximum average planar linear hcat gueration rate (l'/.PUICR) for the EXXON nuclear fuel using the l

following coaditions:

1.

Cap conductance valuct. applicable are those found in Figure 3-10 of Reference (2).

2.

Densificatior effects, as detailed in Reference (1),

are to be included.

3.

The cniculational techniques used are those employed in the analysis presentsd in Referer.ce (4).

4.

All cther requirements of the Interim Acceptance Criterin are to be met.

This enlculation has been performed. The results indicate that a M'.H HGR of 13.4 W/f t ir reqdyrd to reet the 2300eF pf al: dad trrpercture I f nj t. The yt N Nes further postuh.ted _that nn additional consert ative naarpin of WC is 1.zdud N be s wilied to the et.lculeted peak clad ter.ptrature for E.ur.N fuci due to currer.t stait concerns over uncertainty ir the sprny heat b

assi /

960415dO74 960213 PDR FOIA DEKOK95-258

PDR,

(:1

.i a

i Mr. Robert J. Schemel Page II August 24, 1973 a

, transfer coefficients utilized in the calculaticr.. h'hile it is the technical judgment of both Jersey Central Power 4 Light Company and EXXON that the utilization of these coefficients is valid and appropriately conservative in accordancc with the Interim Acceptance Criteria, an additional reduction,of the MAPLHGR to 10.8 KW/ft is dictated by the additional 1000 margin. The application of a MAPLliGR under the conditions defined above results in a calculated PCT of 22000F for EXXON Type III E fuel.

It is understood by Jersey Central Power 6 Light Company that these particularly conservative restrictions on the operation of the EXXON fuel in the Oyster Creek Nucicar Generating Station are temporary in nature and that-a meeting is to be held to resolve the Staff concerns within the next week.

Very truly yours

-W' Nyf'e

, k L s k e

Shep. d Bartnoff

/

ar President j

ph

^

1 1

I l

1

's s

.=.

7

,q

=

.-(.-

).

i e

t y

4 j

1 i^

t l

~

(

14:

Jamas P. O'Re$129

~g 1)}reclaratu of Rogulutory Opurullons Royltus 1 632 Path IsWenuo l

Riny of Pruss1hb Pennsylvania 19400 l

i Vrom Jorticy Contrn) Poder (< Myht Compang Oynter Cycch Nuc)c:st Generating Stat.Jon Hochet ('50.229 Vorhcd River, Rete Jerkey OW31 -

1

!;nbject:t N>nors;.n] Occurrence Repos t 3.jp_,._,

-Tho following its a prc)$sainnry report )>oing cuht:;itt.cd

$n cornpliance v)th the Technica] Speci11ustionu paragraph G.6.2 a

i Pr0)llitillary /spproVOlt

. s 1.

bW

$$2W3.._

g,J. T. Catro)), Jr.

ht t-e cc2 Hr. Is. Giunbust.o i

I h\\

'j3djiUPObb 4

J Abnonnal, f)ccurrence

(-

)

?

' Report No, 73-19 l

e-j i

SUDJECT:

Vlointion of tha Tcchnical Specification, paragraph J.6.c, g

whcrcas the ansximum donunt of rasiloactivity, cxcluding tritluta a noble g150s, and inatopinn W1tl) Ly <3 das)s contained in the rad-wastc storaye tanks external to the radwnnta building exceeded 10 cutles.

1*hla event le considarca to bc an abnottnal vacurrence as defined in the Technical Spect ficationso paragraph 1,153, llot1[1c&llon of thin event, as required by the Technical Specificationsy patarjruph 6.6.2.n, was tuda to Asc Rcgion 1, Directorate of Pegulatort) aparat innn, by tcinphone ots Wednesday, Auguet 23, 1973r at il100 a.m., and by telecopier at 4:15 p,tu.

$1'L'Ukt'RW A routine analysin of the activity contained in the outside i

radsast$ tanks was mado and indicated the total activity to be 11.tI2 curins with 11,28 curies being contained in the Waste Surgc Tank. In reviewing the outelde thnk activitti statun shacen and i

the radiaste logs, an annumption can bc made that the actLVits) hae been in exccan of 10 curies since Friday n>rning, Aurjust 17, The apparent roanon for this acLivity not being detected in samples tokon Friday unurning, Saturday itvinin(1, and Mondat; mornings j

Wd8 d [cdluXe lo YeCirculatn the tank for a sufficient FctiCd of time to elim.inate ans; stratification which ray have been ytesent.

  • luricarassedr9s a

.".-..._p..,

'g.' p.mu*

s 4

{,

)

gauss:

Due to an eppezent' plugging of the wasta cancancratar tube bundic which becare evident Wednesday, August 15, plan.7 wayn initiated tu repince the element. The Haste Surge ' rank, which had edsentiallt) been drainrd, was unod to accot'irradatc Vaste input into the radwasta systcms. In subscquent radlochemical analyses of the watet added to the tank starting on ' Thursday, August 16, at 2:00 p.m. the act1Vity in the tank was found to be primarlist as a result of particulata unatter in suspcnnian, a quantity of particulate taaterial had been known to ha in tha tank from a prior inspection, and a purchase ordor has bcon leeued to an Ouleide conc +tn to clean tha tank and dingosc af thc wantc, Duu to the length of 1me 1equired for thi8 job, thou:h, the tank had not yat baan trade availabic for cicaning, HowcVer, in adding Water to tha tank on Aufwt. 46 and 17, it can he shown b'y comparinon of previous analyne.c of l

l the tark contents, that a quantity of Bolid or particulate

)i material was added WlU) the Water. It Wis this additional rnatcsial that causca a significant increase in the total curl" I

k content of the tank, ny.10:37 a,m., Friday, August 17, apptcxi-cutaly JJ,000 gallon of water had been transferred to the tank.

No additional Waler has been added to tha tank sincc that tienc, l

EU:MDfsu. net 10.y i

With the return of, the Uaste Concentrator to service late i

Saturday night, August 18, overall water inventury in the vatlous radwantn syntatm han slowly bcen accccasing. As sufficient covet is made in the tanks internal to the buiiding, vaste water train i

.s

)

the Surge T.snk wl!1 he transtatted to reduce the ovorall activity, e.

y The aton surrounding ^ the tank has been to-surynyad and 'ro-postcd

'uccordingly. nach opcrators and chendatry techniciann have been udVided that in the (Utura rceirculdblon O! the contents of th0 Surge Tank should be condacted for a 'Bufficient poriod of titx to insura proper reprenentative eutnples an t nubw xnt analysis may be exwpleted.

S, Aft lTY 37917ricnicct Aa noted in tha Technical Spccifications, lit:dting the activit;y stored in tho outside tanks to <10 curies assures that in che evant of a rupturc of the tank.e the resulting activity dis ~

r charged to the bay would not be greater than the maximum activity recowended as the 1 igniting condition for operation for the armual told 1 quantity rcicasca in effluents given in the propm:cd Appendix 1 to 10ctR50. Lue in this cases to tho activity beltog s

i primArily 43 a result; nt particulatc matter in easpeneion, it.1s

(

nut felt that the tcuterial wquid bc dcposited in the bay, but rather would be in the surrounding soil, never to reach the bays shouid tha tank rupturc, Consequent 14o the eignI.t'Icanca af chie event is adnitml.

1

/j //

Prepared by:._.f/' k b

$, 23 lb.

In te ou. =.,

t 1

1

.-s=

m

. g, g g.

'