631 Park Avenue
1-
King of Prussia, Pennsylvania 19400CT g C Jgg
,
j
Jersey Cenerst Power and Light company
Docket Es. 50-219
Attention: k . Ivan R. Fimfrock
ti - ae No. DFR-16
.
Vice President Generatien
j
Hadisse Avemme at Pisach Bowl Reed
j
Morristems, New Jersey 07960
I
Gentlemen:
l
Sis refers to the special inapa**h ese6astad by k. eseemnan of this
.
i
office em September 10-12, 1973 of eetivities methorized by ABC License
!
No. err-16 and to the discussions of our findings held by Mr. Greenman
with Mr. Carroll and others of your staff at the eenclusion of the in-
.
opection.
i
j
Areas examined during this inspection are described in the Regulatory
j
Operations Inspection Report which is anciesed with this letter. Within
l
these areas, the inspection consisted of selective aminations of pro-
l
j
cedures and representative records, interviews with personnel, and ob.
'
I
servations by the inspector.
,
!
During this inspection, it was found that certain of your activities
appeared to be in violation of AEC requirenants. W e iten and refer-
,
,
ences to the pertinent requirements are listed in the enclosure to this
,
,
'
letter. h is letter constitutes a notice sent to you pursuant to the
.
4
l
provisions of Section 2.201 of the AEC's " Rules of Practice", Part 2,
Title 10, Code of Federal Regulations. Section 2.201 requires you to
submit to this office within 20 days of your receipt of this notice, a
l
vritten statement of exp1 mation in reply, including:
(1) corrective
1
!
steps which have been or will be taken by you, and the results achieved;
l
(2) corrective steps which will be taken to avoid further violations;
and (3) the date when full compliance will be achieved.
I
t
With respect to the inoperability of the startup tramoformers which are
!
required pursuant to Technical Specificatian 3.7.A.2', your couTective
l
action was described in your letter to the Directorate of Liammoing dated
l
Septeu6er 18,1973; therefore, ao reply is seguired with respect to this
Bewever, in addition to the need for eersective action betag taken
l
matter.
and described in the abose soferenced latter, se are consermed about the
'
l
l
1sg>1====tattaa of your Quality Assersmos Progren that passaitted these
deficiencias to enour. Wely, in yoner reply to this letter.
.'
i
please dancribe in particular, thama actimes tahma or pid to tauprove
l
the effectiveness of your Quality Assurance end centrol, and the dates
j
i
l
uhan these acticas will be accongildead.
^
f.
l
Cabson
O'Reilly
'
!
Greenma her
aphton
k
10/26/73
4
72 -
9604120214 960213
I.
DEKCK95-258
.I
_.
.
-
.
.
.
-
.
.
,
.
Jersey Central Power and Light company
License No. DPR-16
Page 2
This letter also confirms the meeting to be held at this office on
November 5,1973 at 10:00 a.m., with Mr. W. Kuhn, President, seneral
Publie Utilities Corp., Dr. 8. Bertneff, PreaMane, Jersey Central Power
and Light Company, and other senior representativas of the JtTf4L Co.
conseeming the results and signifiaance of the large sunbar of de-
fielencies identified during our ausmented inspection progran at the
Oyster Creek facility.
Should you have any questians eonearning this inspection, we will be
pleased to discuss them with you.
Sincerely,
James P. O'Reilly
Director
Enclosures:
1.
Description of Violations
2.
RO Inspection Report No. 50-219/73-15
cc:
Mr. J. T. Carroll, Plant Superintendent
i
Oyster Laeek Nuclear Station
Jersey Central Power and Light Company
Forked River, New Jersey 08731
4
.
i
bec:
RO Chief, FS&EB (1 w/encls.)
RO:HQ (5 w/encis.)
l
DL (4 w/encis., plus 9 cys. of Report only)
'
!
DR Central Files (1 w/ enc 18.)
RS (3 w/encls.)
R0 Files (1 w/encls.)
i
PDR (1 v/encis.)
l
Local PDR (1 w/encls.)
'
NSIC (1 w/encis.)
i
DTIE (1 w/encis.)
8
!
State of NewJersey (1 w/encls.)
'
I
i
!
!
!
l
,
- - .
.
-
.
.
- -