MONTHYEARML20196G4021999-06-18018 June 1999 Comment on FRN Re Rev of NRC Enforcement Policy NUREG-1600, Rev 1 & Amend of 10CFR55.49.Concurs with Need to Provide Examples That May Be Used as Guidance in Determining Appropriate Severity Level for Violations as Listed ML20206H1881999-05-0606 May 1999 Exemption from Requirements of 10CFR50,App K Re ECCS Evaluation Models. Commission Grants Licensee Exemption ML20206M5111999-04-30030 April 1999 Comment Supporting Draft RG DG-1083 Re Content of UFSAR IAW 10CFR50.71(e). Recommends That Listed Approach Be Adopted for Changes to Documents Incorporated by Ref CY-99-007, Comment Supporting Proposed Changes to Improve Insp & Assessment Processes for Overseeing Commercial Nuclear Industry That Were Published in Fr on 990122 & in SECY-99-0071999-02-22022 February 1999 Comment Supporting Proposed Changes to Improve Insp & Assessment Processes for Overseeing Commercial Nuclear Industry That Were Published in Fr on 990122 & in SECY-99-007 TXX-9825, Comment Endorsing NEI Comments on Proposed Rulemaking to 10CFR50.65, Requirements for Monitoring Effectiveness at Npps1998-12-14014 December 1998 Comment Endorsing NEI Comments on Proposed Rulemaking to 10CFR50.65, Requirements for Monitoring Effectiveness at Npps ML20154C4101998-09-30030 September 1998 Comment Re Proposed Rule 10CFR50 Re Reporting Requirements for Nuclear Power Reactors.Comanche Peak Electric Station Endorses NEI Comment Ltr & Agrees with NEI Recommendations & Rationale ML20216E1051998-04-0707 April 1998 Comment Supporting Draft RG DG-1029 Titled Guidelines for Evaluating Electromagnetic & Radio-Frequency Interference in Safety-related Instrumentation & Control Sys ML20217H3611998-03-26026 March 1998 Comment Opposing Draft GL 97-XX, Lab Testing of Nuclear Grade Charcoal, Issued on 980225.Advises That There Will Be Addl Implementation Costs ML20198Q4851998-01-16016 January 1998 Comment Opposing PRM 50-63A by P Crane That Requests NRC Amend Regulations Re Emergency Planning to Require Consideration of Sheltering,Evacuation & Prophylactic Use of Potassium Iodide for General Public ML20211A4871997-09-12012 September 1997 Changes Submittal Date of Response to NRC RAI Re Proposed CPSES risk-informed Inservice Testing Program & Comments on NRC Draft PRA Documents ML20149L0311997-07-21021 July 1997 Comment on Draft Guides DG-1048,DG-1049 & DG-1050.Error Identified in Last Line of DG-1050,item 1.3 of Section Value/Impact Statement.Rev 30 Should Be Rev 11 ML20140A4871997-05-27027 May 1997 Comment Opposing Proposed Rule Re Safety Conscious Work Environ.Util Agrees W/Nuclear Energy Inst Comment Ltr ML20133G5411996-12-0505 December 1996 Transcript of 961205 Meeting in Arlington,Tx Re Comanche Peak Thermo-Lag Fire Barriers. Pp 1-111 ML20135B7881996-11-29029 November 1996 Order Approving Corporate Restructuring of TU to Facilitate Acquistion of Enserch Corp ML20128M8011996-10-0303 October 1996 Comment Opposing Proposed NRC Generic Communication, Primary Water Stress Corrosion Cracking of Control Rod Drive Mechanism & Other Vessel Head Penetrations ML20097D7321996-02-0909 February 1996 Comment Opposing Petition for Rulemaking PRM-50-63 Re CPSES Request for Amend to Its Regulations Dealing W/Emergency Planning to Include Requirement That Emergency Planning Protective Actions for General Public Include Listed Info ML20094Q6421995-11-28028 November 1995 Comment Supporting Petition for RM PRM-50-62 Re Amend to Regulation Re QAPs Permitting NPP Licensees to Change Quality Program Described in SAR W/O NRC Prior Approval If Changes Do Not Potentially Degrade Safety or Change TSs ML20094H4801995-11-0808 November 1995 Comment Supporting Nuclear Energy Inst Comments on Proposed Rules 10CFR60,72,73 & 75 Re Safeguards for Spent Nuclear Fuel or high-level Radwaste ML20091M6441995-08-25025 August 1995 Comment Opposing Proposed Rule Re Review of Revised NRC SALP Program.Believes That NRC Should Reconsider Need for Ipap or SALP in Light of Redundancy ML20086M7921995-07-0707 July 1995 Comment Supporting Proposed GL Process for Changes to Security Plan Without Prior NRC Approval ML20084A0181995-05-19019 May 1995 Comment Suporting Proposed Rule 10CFR50 Re Containment Leakage Testing.Supports NEI Comments ML20077M7311994-12-30030 December 1994 Comments Opposing Proposed Rule 10CFR50 Re Shutdown & Low Power Operations for Nuclear Power Reactors ML20077L8711994-12-22022 December 1994 Comment Supporting Proposed Rule 10CFR50,55 & 73 Re Reduction of Reporting Requirements Imposed on NRC Licensees ML20073B6731994-09-19019 September 1994 Affidavit of Cl Terry Re License Amend Request 94-015 ML20073B6951994-09-19019 September 1994 Affidavit of Cl Terry Authorizing Signing & Filing W/Nrc OL Amend Request 94-016 ML20058E0561993-11-10010 November 1993 Comment on Proposed Rule Re Staff Meetings Open to Public. Believes That NRC Has Done Well in Commitment to Provide Public W/Fullest Practical Access to Its Activities ML20056G3351993-08-27027 August 1993 Comment Opposing Proposed Rule 10CFR2 Re Review of 10CFR2.206 Process ML20045D8321993-06-11011 June 1993 Comment Supporting Proposed Rules 10CFR50 & 54, FSAR Update Submittals. ML20044F3271993-05-21021 May 1993 Comments on Draft NRC Insp Procedure 38703, Commercial Grade Procurement Insp, Fr Vol 58,Number 52.NRC Should Use EPRI Definitions for Critical Characteristics ML20056C0831993-03-19019 March 1993 Texas Utils Electric Co Response to Petitioners Motion to Stay Issuance of Full Power License.* Licensee Urges NRC to Reject Petitioners Motion & to Deny Petitioners Appeal of 921215 Order.Motion Should Be Denied.W/Certificate of Svc ML20056C1881993-03-17017 March 1993 Order.* Directs Util to Respond to Motion by COB 930319 & NRC to Respond by COB 930322.W/Certificate of Svc.Served on 930317 ML20128D9651993-02-0303 February 1993 Memorandum & Order.* Stay Request Filed by Petitioners Denied.W/Certificate of Svc.Served on 930203 ML20128F6221993-02-0303 February 1993 Transcript of 930203 Affirmation/Discussion & Vote Public Meeting in Rockville,Md.Pp 1-2.Related Info Encl ML20128D3391993-02-0202 February 1993 Emergency Motion to Stay Issuance of low-power Ol.* Petitioners Specific Requests Listed.W/Certificate of Svc ML20128D4651993-02-0202 February 1993 Texas Utils Electric Co Response to Emergency Motion to Stay Issuance of low-power Ol.* Petitioner Request Should Be Denied Based on Failure to Meet Heavy Burden Imposed on Party.W/Certificate of Svc ML20128D3461993-01-29029 January 1993 NRC Staff Notification of Issuance of OL for Facility.* Low Power License May Be Issued by 930201.W/Certificate of Svc ML20128D6321993-01-29029 January 1993 Memorandum & Order.* Denies Citizens for Fair Util Regulation for Fr Notice Hearing on Proposed Issuance of OL for Facility.W/Certificate of Svc.Served on 930129 ML20127L9321993-01-26026 January 1993 Affidavit of Re Architzel Re Thermo-Lag Installation at Testing for Unit 2.* Statement of Prof Qualifications Encl ML20128D6111993-01-26026 January 1993 Joint Affidavit of I Barnes & Ft Grubelich Re Borg-Warner Check Valves.* Discusses Issues Re Borg-Warner Check Valves Raised by Cfur & Adequacy of Actions Taken by TU Electric ML20127L9181993-01-26026 January 1993 NRC Staff Reply to Cfur Request for Publication of Proposed Action Re Licensing of Unit 2.* Cfur Request That Notice Re Licensing of Unit 2 Be Published Permitting Parties to Request Hearings Should Be Denied ML20127L9661993-01-26026 January 1993 Affidavit of Rl Pettis Re Borg-Warner Check Valves.* Statement of Prof Qualifications & Certificate of Svc Encl ML20127L9091993-01-25025 January 1993 Tx Util Electric Response to Citizens for Fair Util Regulation Request of 930113.* Request Fails to Raise Worthy Issue & Should Be Denied.W/Certificate of Svc ML20127L8891993-01-21021 January 1993 Order.* License Should File Response to Citizens for Fair Util Regulation Ltr Requesting That Commission Issue Fr Notice Providing for Opportunity for Hearing Re Issuance of OL by 930125.W/Certificate of Svc.Served on 930122 ML20127G9191993-01-19019 January 1993 Order.* Grants Petitioners Extension of Time Until 930122 to File Brief.Replies to Petitioners Brief Shall Be Filed on or Before 930208.W/Certificate of Svc.Served on 930119 ML20127G9441993-01-19019 January 1993 TU Electric Brief in Opposition to Petitioners Appeal of ASLB Memorandum & Order.* Requests That Petitioners Appeal Be Denied & Licensing Board 921215 Memorandum & Order Be Affirmed.W/Certificate of Svc ML20127G8041993-01-15015 January 1993 NRC Staff Response to Appeal of Licensing Board Decision Denying Petition for Leave to Intervene & Request for Hearing Filed by Bi & Di Orr.* Board 921215 Decision Should Be Upheld.Certificate of Svc Encl ML20127G7451993-01-14014 January 1993 NRC Staff Response to Motion of Petitioners RM Dow & SL Dow, (Disposable Workers of Comanche Peak Steam Electric Station),For Leave to File Out of Time & Request for Extension of Time to File Brief.* W/Certificate of Svc ML20127G7941993-01-12012 January 1993 Opposition of TU Electric to Motion for Leave to File Out of Time & Request for Extension of Time to File Brief by SL Dow (Disposable Workers of Comanche Peak Steam Electric Station) & RM Dow.* W/Certificate of Svc ML20127A5931993-01-0808 January 1993 Brief in Support of Petitioner Notice of Appeal.Aslb Erred by Not Admitting Petitioner Contention & Action Should Be Reversed.W/Certificate of Svc ML20127A6371993-01-0707 January 1993 Notice of Appeal.* Appeal Submitted Due to 921215 Memo Denying Petitioner Motion for Rehearing & Petition for Intervention & Request for Hearings.Proceedings Were Terminated by Aslb.W/Certificate of Svc 1999-06-18
[Table view] Category:PLEADINGS
MONTHYEARML20056C0831993-03-19019 March 1993 Texas Utils Electric Co Response to Petitioners Motion to Stay Issuance of Full Power License.* Licensee Urges NRC to Reject Petitioners Motion & to Deny Petitioners Appeal of 921215 Order.Motion Should Be Denied.W/Certificate of Svc ML20128D3391993-02-0202 February 1993 Emergency Motion to Stay Issuance of low-power Ol.* Petitioners Specific Requests Listed.W/Certificate of Svc ML20128D4651993-02-0202 February 1993 Texas Utils Electric Co Response to Emergency Motion to Stay Issuance of low-power Ol.* Petitioner Request Should Be Denied Based on Failure to Meet Heavy Burden Imposed on Party.W/Certificate of Svc ML20127L9091993-01-25025 January 1993 Tx Util Electric Response to Citizens for Fair Util Regulation Request of 930113.* Request Fails to Raise Worthy Issue & Should Be Denied.W/Certificate of Svc ML20127G9441993-01-19019 January 1993 TU Electric Brief in Opposition to Petitioners Appeal of ASLB Memorandum & Order.* Requests That Petitioners Appeal Be Denied & Licensing Board 921215 Memorandum & Order Be Affirmed.W/Certificate of Svc ML20127G7451993-01-14014 January 1993 NRC Staff Response to Motion of Petitioners RM Dow & SL Dow, (Disposable Workers of Comanche Peak Steam Electric Station),For Leave to File Out of Time & Request for Extension of Time to File Brief.* W/Certificate of Svc ML20127G7941993-01-12012 January 1993 Opposition of TU Electric to Motion for Leave to File Out of Time & Request for Extension of Time to File Brief by SL Dow (Disposable Workers of Comanche Peak Steam Electric Station) & RM Dow.* W/Certificate of Svc ML20127A6131993-01-0707 January 1993 Motion for Leave to File Out of Time & Request for Extension of Time to File Brief.* Petitioners Did Not Receive Order in Time to Appeal & Requests 15 Day Extension from Motion Filing Date to Respond.W/Certificate of Svc ML20127A7911992-12-31031 December 1992 Petitioner Amended Motion for Continuance to File Appeal Brief.* Petitioners Requests Until C.O.B. on 930108 to File Appeal Brief.W/Certificate of Svc ML20127A7641992-12-30030 December 1992 Petitioner Motion for Continuance to File Appeal Brief.* Counsel Requests That Petitioners Be Granted Until 930109 to File Brief in Support of Notice of Appeal.W/Certificate of Svc ML20128C9751992-12-0303 December 1992 NRC Staff Response to Motion to Compel Disclosure of Info Secreted by Restrictive Agreements & Notification of Addl Evidence Supporting Petition to Intervene by B Orr,D Orr, J Macktal & Hasan.* W/Certificate of Svc ML20128B8721992-11-27027 November 1992 NRC Staff Response to Motion for Rehearing by RM Dow, Petitioner.* Motion for Rehearing Should Be Denied for Reasons Explained in Encl.W/Certificate of Svc ML20128A0271992-11-25025 November 1992 Texas Utilities Electric Co Answer to Motion to Compel Disclosure of Info Secreted by Restrictive Agreements.* Util Requests That Petitioners 921118 Motion to Compel Be Denied in Entirety.Certificate of Svc Encl ML20127P8181992-11-25025 November 1992 Texas Utilities Electric Co Answer to Notification of Addl Evidence Supporting Petition to Intervene.* Petitioners Notification Procedurally Improper & Substantively Improper & Should Be Rejected by Board.W/Certificate of Svc ML20116M4591992-11-19019 November 1992 TU Electric Opposition to Motion for Rehearing by RM Dow.* RM Dow 921110 Motion for Rehearing Should Be Denied.W/ Certificate of Svc ML20127M4271992-11-15015 November 1992 Motion to Compel Disclosure of Info Secreted by Restrictive Agreements.* Petitioners Bi Orr,Di Orr,Jj Macktal & SMA Hasan Requests That Board Declare Null & Void Any & All Provisions in Settlement Agreements.W/Certificate of Svc ML20116M3181992-11-10010 November 1992 Motion for Prehearing by RM Dow,Petitioner.* Requests Period of Ten Days to File Supplemental Pleading to Original Petition.Certificate of Svc & Statement Encl ML20106D8881992-10-0808 October 1992 Opposition of Util to Motion for Extension of Time to File Brief by SL Dow Doing Business as Disposbale Workers of Plant & RM Dow.* Request for Extension of Time & to Become Party to Proceeding Should Be Rejected.W/Certificate of Svc ML20106D2821992-10-0505 October 1992 Motion for Extension of Time to File Brief by SL Dow Doing Business as Disposable Workers of Comanche Peak Steam Electric Station & RM Dow.* Petitioner Requests 30-day Extension.W/Certificate of Svc ML20101P5891992-06-30030 June 1992 Response of Texas Utils Electric to Comments of Cap Rock Electric Cooperative,Inc. Dispute Strictly Contractual Issue Involving Cap Rock Efforts to Annul Reasonable Notice Provisions of 1990 Power Supply Agreement ML20127K8141992-05-19019 May 1992 Request to Institute Proceeding to Modify,Suspend or Revoke License Held by Util for Unit 1 & for Cause Would Show Commission That Primary Place of Registration for Organization Is Fort Worth,Tarrant County,Tx ML20096A6281992-05-0707 May 1992 Applicants Reply to Opposition cross-motions for Summary Disposition & Responses to Applicants Motion for Summary Disposition.* Applicants Conclude NRC Has No Authority to Retain Antitrust Licensing Conditions.W/Certificate of Svc ML20095C4691992-04-17017 April 1992 TU Electric Answer to Application for Hearings & Oral Argument by M Dow & SL Dow.* Concludes That NRC Should Deny Application for Oral Argument & Hearings on Petition to Intervene & Motion to Reopen.W/Certificate of Svc ML20091E2561992-04-0606 April 1992 Application to Secretary for Hearings & Oral Argument in Support of Motion for Leave to Intervene out-of-time & Motion to Reopen Record Submitted by SL Dow Dba Disposable Workers of Comanche Peak Steam Electric Station & RM Dow.* ML20094K4161992-03-16016 March 1992 TU Electric Answer to Petition to Intervene & Motion & Supplemental Motion to Reopen by M Dow & SL Dow & TU Electric Request for Admonition of Dows.* Concludes That Motion Should Be Dismissed.W/Certificate of Svc ML20091A0461992-03-13013 March 1992 Suppl to Motion to Reopen Record.* Requests That NRC Reopen Record & Suspend License Pending New Hearings on Issue. W/Certificate of Svc ML20090C4241992-02-24024 February 1992 Motion to Reopen Record.* Requests That NRC Reopen Record & Suspend OL for Unit 1 & CP for Unit 2,pending Reopening & Final Decision.W/Certificate of Svc ML20090C4431992-02-21021 February 1992 Petition for Leave to Intervene Out of Time.* Requests That Petition for Leave to Intervene Out of Time Be Granted for Listed Reasons.W/Certificate of Svc ML20086Q3811991-12-26026 December 1991 Case Response to Portions of Motion of R Micky & Dow to Reopen Record.* Submits Responses to Motions to Reopen Record ML20086Q3121991-12-26026 December 1991 Case Motion for Leave to File Response to Portions of Motion of R Micky & Dow to Reopen Record.* Requests That NRC Recognize J Ellis as Case Representative for Filing & Pleading Purposes.W/Limited Notice of Appearance ML20091G2511991-12-0202 December 1991 Licensee Answer to Motion to Reopen Record by M Dow & SL Dow.* Requests That Petitioners Motion Be Denied for Listed Reasons.W/Certificate of Svc & Notices of Appearance ML20086G7381991-11-22022 November 1991 Motion to Reopen Record.* Requests That Licensing Board Reopen Record & Grant Leave to File Motion to Intervene. W/Certificate of Svc ML20006C4811990-02-0101 February 1990 Applicant Answer to Request for Stay by Citizens for Fair Util Regulation (Cfur).* Cfur Failed to Satisfy Burden to Demonstrate Necessity for Stay & Request Should Be Denied. Certificate of Svc Encl ML20006B1691990-01-27027 January 1990 Second Request for Stay Citizens for Fail Util Regulation.* Requests That NRC Stay Fuel Loading & Low Power Operation of Unit 1 Until 900209.Certificate of Svc Encl ML20248J3601989-10-15015 October 1989 Request for Stay Citizens for Fair Util Regulation.* Requests That Commission Retain Authority to Order That Fuel Loading & Low Power License Not Be Immediately Effective,Per Util Intent to Request License.Certificate of Svc Encl ML20246B8671989-08-17017 August 1989 Motion for Reconsideration of NRC Memorandum & Order CLI-89-14.* NRC Should Excuse Itself from Consideration on Matters Re Jj Macktal & Should Refer All Issues on NRC Requested Subpoena to Independent Adjudicatory Body ML20248D6291989-08-0202 August 1989 Jj Macktal Statement Re Motion for Recusation.* Macktal Motion Considered Moot Due to Commission No Longer Having Jurisdiction to Consider Motion Since Macktal Not Party to Proceeding Before Nrc.W/Certificate of Svc ML20247Q3851989-07-26026 July 1989 Withdrawal of Motion to Reopen Record.* Withdraws 890714 Motion to Reopen Record.W/Certificate of Svc ML20245J7331989-07-26026 July 1989 Request of Cap Rock for Reevaluation of Director'S Determination That No Significant Changes in Licensee Activity Warrant Antitrust Review at OL Stage.Certificate of Svc Encl ML20247B5901989-07-19019 July 1989 Motion to Reopen Record.* Requests Board to Reopen Record & Grant Leave to Renew Earlier Motion for Intervention Status. W/Supporting Documentation & Certificate of Svc ML20248D5731989-07-0303 July 1989 Motion for Reconsideration.* Requests Reconsideration of NRC 890122 Order on Basis That NRC Subpoena Filed for Improper Purposes & NRC Lacks Jurisdiction Over Matters Presently Before Dept of Labor ML20248D5541989-07-0303 July 1989 Motion for Recusation.* Requests That NRC Recuse from Deciding on Macktal Cases on Basis That NRC Will Not Be Fair & Impartial Tribunal.W/Certificate of Svc ML20245J9411989-06-30030 June 1989 Response of Texas Utils Electric Co to Request of Cap Rock Electric Cooperative,Inc,For Order Enforcing & Modifying Antitrust License Conditions ML20248D4891989-06-13013 June 1989 Motion for Protective Order.* Requests That Jj Macktal Deposition Be Taken at Stated Address in Washington,Dc & That Testimony Remain Confidential.W/Certificate of Svc ML20011E8571989-02-10010 February 1989 Reply of Cap Rock Electric Cooperative,Inc to Comments of Texas Utils Electric Co.* Texas Utils Response Considered Irrelevant,Mainly Incorrect or Misleading.Certificate of Svc Encl ML20155A8251988-10-0303 October 1988 NRC Staff Response to Citizens for Fair Util Regulation First Suppl to Request for Hearing & Petition for Leave to Intervene.* Petition & Requests for Hearings Should Be Denied.W/Certificate of Svc ML20154Q2021988-09-28028 September 1988 Applicant Reply to Citizens for Fair Util Regulation (Cfur) First Suppl to 880811 Request for Hearing & Petition for Leave to Intervene.* Cfur Request Should Be Denied. Certificate of Svc Encl ML20150E2131988-07-13013 July 1988 Citizens Audit Motion for Stay & Motion for Sua Sponte Relief.* Requests Time to Review Concerns of J Doe & for Relief for Listed Items in Order to Act as Intervenor in Proceeding.W/Certificate of Svc ML20151A6181988-07-12012 July 1988 Motion for Petitioners to Appear Pro Se.* Petitioners Request to Appear Before Board at 880713 Hearing in Order to Present Arguments in Support of Petitioners Motions & for Stay of Proceedings.W/Certificate of Svc ML20150E1831988-07-12012 July 1988 Response of Applicant to Motions to Stay,To Intervene & for Sua Sponte Relief Filed by Various Petitioners.* Papers Filed by Petitioners Should Be Rejected & Denied & Dismissal of Proceedings Be Completed.W/Certificate of Svc 1993-03-19
[Table view] |
Text
_ _ _ _ _ _ - _ _ _ _ _ _ - - .
, , RELIMC C ,
.m g l l
C F('j.Ij:
UNITED STATES OF AMERICA 34 di ~2 I'O I' NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matte of )
)
TEXAS UTILITIES ELECTRIC ) Docket Nos. 50-445 and COMPANY, et al.
) 50-446
) ,
(Comanche Peak Steam Electric ) (Application for l Station, Units 1,and 2 ) ) Operating Licenses)
APPLICANTS' MOTION FOR
SUMMARY
DISPOSITION OF CASE'S ALLEGATIONS l REGARDING CINCHING DOWN OF U-BOLTS I
' Pursuant to 10 C.F.R. $ 2.749, Texas Utilities Electric Company, et al. (" Applicants") hereby move the Atomic Safety and ,
Licensing Board (" Board") for summary disposition of the Citizens Association for Sound Energy's (" CASE") allegations regarding Cinching Down of U-bolts. As demonstrated in the accompanying a f fidavit of R.C. Iotti and J.C. Finneran, Jr. Regarding Cinching Down of U-Bolts (" Affidavit") (Attachment 1) and Statement of Material Facts (Attachment 2), there is no genuine issue of fact to be heard regarding this issue. Applicants urge the Board to so find, to conclude that Applicants are entitled to a favorable decision as a matter of law, and to dismiss this issue from this proceeding.
8407020518 840629 PDR ADOCK 05000445 O PDR
I. BACKGROUND In August, 1982, intervenor CASE deposed Mr. Jack Doyle, a former employee of Applicants, with respect to certain allegations Mr. Doyle had regarding the design of pipe supports at Comancho Peak. Mr. Doyle's deposition was subsequently admitted into the record in this proceeding as his testimony (CASE Exhibit 669; Tr. 3631). One issue raised by Mr. Doyle concerned the impacts of cinching down of U-bolts. CASE Exhibit 669 at p. 201-202, 206-213. All parties presented testimony on this issue, e.g., CASE Exhibit 763 Item 11-14, Applicants Exhibit 142F at 5 and NRC Staff Exhibit 207 at 31-34.
Following litigation of the pipe support design allegations, each of the parties submitted proposed findings addressing, inter alia, allegations regarding cinching down of U-bolts. (See Applicants' Proposed Findings of Fact Concerning Pipe Support Design Questions (August 5, 1983) at 47-50; NRC Staf f's Proposed Findings of Fact ( August 30, 1983) at 53-56; CASE's Proposed Findings of Fact and Conclusions of Law (August 22, 1983),
Section IV; and Applicants' Reply to CASE's Proposed Findings of Fact and Conclusions of Law (September 6, 1983) at 17-19).
In its Memorandum and Order of December 28, 1983 concerning design issues at 25-28 and 33-41, the Board stated that the record was not adequate to provide reasonable assurance that U-bolts would provide the appropriate clamping force to prevent
IO 3-instability without adversely impacting the piping system or the U-bolts. By Memorandum and Order of February 8, 1984 a t 19-26, the Board reaffirmed its earlier decision.
This motion addresses CASE's concerns regarding the impact of cinching down of U-bolts, as set forth in its Proposed Findings of Fact at Section IV and summarized in the Board's December 28, 1983 and February 8, 1984 Orders. In responding to these concerns, Applicants provide the information which they committed to generate as part of Applicants' Plan to Respond to Memorandum and Order (Quality Assurance for Design) (" Applicants' Plan") at 5-6, items 3, 4 and 5 (February 3, 1984).
II. APPLICANTS' MOTION FOR
SUMMARY
DISPOSITION A. General Applicants have previously discussed the legal requirements applicable to motions for summary disposition in their " Motion for Summary Disposition of Certain CASE Allegations Regarding AWS and ASME Code Provisions Related to Welding," filed April 15, 1984 (at 5-8), incorporated herein by reference.
D. CASE's Allegations Regarding Cinching Down of U-bolts Should Be Summarily Dismissed In Section IV of its Proposed Findings, CASE makes allegations regarding this issue which may be categorized into the following three basic areas:
- 1. The stability of cinched-down U-bolt clamping assemblies to include the maintenance of adequate clamping forces (see the December 28, 1983 Memorandum and Order at 27-25 and 33, and the February 8, 1984 Memorandum and Order at 20-23).
D
- 2. The impact of forces and stresses induced in the U-bolt itself (see December 28, 1983 Memorandum and Order at 33-5, and February 8, 1984 Memorandum and Order at 24-5).
- 3. The impact of forces and stresses induced in the pipe by the cinching down practice ( see December 28, 1983 Memorandum and Order at 33-40, and February 8, 1984 Memorandum and Order at 25-6).
In responding to these concerns, Applicants committed to provide the following information (see Applicants' Plan to Respond to Memorandum and Order (Quality Assurance for Design) at 5-6 (items 3, 4 and 5)):
"3. Provide evidence that the use of U-bolt cinching is appropriate to eliminate potential local instability without introducing adverse effects in the piping and the U-bolt itself."
"4. Provide evidence that there are no adverse long-term effects from U-bolts caused by heat-up and cooldown and related friction on the pipe."
"5. Provide evidence of the acceptability of stresses on pipes caused by thermal expansion in local areas around cinched U-bolts."
While the primary method used to obtain this information is testing, Applicants recognized that testing could be performed on only a limited number of test specimens. Therefore, Applicants have also performed finite element analyses to obtain additional data. Affidavit at 3-4. The results of this analytical and testing program and associated evaluation are set forth in the attached Affidavit.1 1 In addition, the Affidavit clears up two apparent misunderstandings that the Board exhibited in its December 28, 1983 Memorandum and Order regarding (1) the use of U-bolts in the plant (Affidavit at 4-5) and (2) the use of SA-307 and SA-36 material as friction type connections loaded in shear (Id. at 5-8) .
fi As set forth more fully below, none of CASE's four concerns raises an issue that reflects a breakdown in Applicants' Quality Assurance ("QA") Program or a safety concern in the plant.
Accordingly, no genuine issue of material fact exists with respect to these allegations, and the Board should find that the Applicants are entitled to judgment as a matter of law.
- 1. The Testing Program In that the tests (and corresponding finite element analyses) rely on assumptions regarding the torque applied to U-bolts in the plant, to assure that the tests and analyses accurately represent plant conditions, Applicants conducted a survey of the torque on a representative sample of cinched down U-bolts (see Affidavit at 9-12). From the data, Applicants established that to bound field conditions for 4, 10 and 32 inch pipe, tests should be conducted with preload (torque on bolts) varying from 5 to 60 ft-los., 10 to 100 ft-lbs., and 20 to 240 ft-lbs., respectively. Id. at 10. In all cases, the likelihood of exceeding.these values in the field is very remote. Id. at 11-12..
Applicants' testing program consisted of seven distinct tests. The objectives and results of the seven tests are s ummarized . below:
ls I
l i a. Torque versus Preload Test ( Affidavit at 12-14. )
The objectives of this test were two fold, viz., (1) to establish the relationship between torque applied to a U-bolt nut and the resulting tension in the U-bolt as a l
function of pipe size, and (2) to determine the strain in a
- pipe as a function of preload on the associated U-bolt.
The results of the torque versus preload test indicate
- that for the range of values of concern, a linear relationship of t = KTD exists between the torque imparted
, to a U-bolt nut and the tension developed in the U-bolt, where t is the applied torque, D is the bolt diameter, T is the tension in the bolt and K is a constant that varies between 0.2 5 and 0.3 5. Also, the test reflected that maximum pipe strains (and stresses) caused by preload of the i
! U-bolt are generally found in the circumferential direction, are compressive in nature, and occur generally below the cross piece.
- b. Friction Test (Id. at 14-18. )
The objective of this test was to determine the force on a U-bolt which is needed to cause slippage between the U-bolt / cross piece assembly and the pipe.
The friction test produced two results, viz., (1) the force required to cause slippage between the U-bolt support assembly and the pipe in the plane of the U-bolt (i.e., the
{
L
force tnat produces rotation about the pipe axis), and (2) the coefficient of friction which exists for the U-bolt / cross piece assembly.
- c. Load Distribution / Strain Measurement Test (Id.
~~
at 18-21.)
The objective of this test was to determine the stiffness of the U-bolt assembly, and accordingly, whether thermal expansion and mechanical loads are directly additive to the preload. Applicants had maintained that while expansion loads are additive to preload, total mechanical loads are not directly additive. The results of this test reflect that the mechanical external loads are not directly additive to preload.
- d. Thermal Cycling / Thermal Gradient Test (Id. at 21-25.)
The objectives of th' test were twofold, viz., (1) to determine the additional load (and resulting stresses) on a support and pipe caused by differential thermal expansion of the pipe with respect to the U-bolt, and (2) to assess the relaxation of the U-bolt preload caused by long-term temperature cycling in order to determine whether material relaxation effects w3uld reduce the preload to the extent that slipping of the U-bolt / cross piece can occur.
This test provided the thermal load data for use in the finite element analyses. Further, the results of the test reflect that (1) the maximum relaxation of each specimen can be predicted with reasonable assurance, and (2) where there 4
i are stresses above approximately 1/2 yield, thermal relaxation will occur rapidly until the stress reaches about 1/2 yield (sufficient to retain an adequate clamping force) and then will stabilize.
- e. Creep Test (Id. at 25-26.)
The objective of this test was to determine whether long-term temperature exposure could result in material relaxation so that preload would be decreased or lost. The results clearly reflect that after the initial relaxation achieved during thermal cycling, no further relaxation occurs, and at temperatures of concern creep is not a problem.
- f. Accelerated Vibration Test (Id. at 26-31.)
The objective of this test was to determine whether normal vibration levels in the plant could cause material relaxation, and consequently, loss of preload. In order to simulate 40 years of accumulative effects of piping vibration, this test was run as an accelerated vibration test utilizing vibratory forces varying in frequency from 5 to 200 Hz at an amplitude equal to the maximum expected OBE force for the pipe tested (4000 lbs.) as well as at lower forces (1000-1500 lbs.). The time duration of this test combined with the amplitude of the vibratory (sinusoidal) force resulted in an overall energy input into the test specimen exceeding by orders of magnitude the energy that would be induced by an earthquake (both operating basis and
l L design basis earthquakes). This test simulates conditions
-far more severe than expected in the plant for normal I vibration levels.
t-The results of.the test reflect that after an initial repositioning of the assembly, .which reduces the preload a
- "relatively small amount, no further decrease in preload was L
observed, indicating that the vibration per se had no effect on relaxation.
- g. Seismic Test (Id. at 31-34. )
The objective of this test (an auxiliary test to the accelerated vibration test, noted above) was to test the i
effect on the U-bolt assembly of the peak force for the safe shutdown earthquake, 7000 lbs. Although due to mechanical l
l failure of the test equipment the test was not capable of
'being totally completed, the results of those portions completed supported determinations in previous tests.
i
! 2. Finite Element Analyses
,Each U-bolt assembly tested was modeled with a finite element analysis utilizing MSC NASTRAN Version 63. Id. at 42.
This computer code was chosen because it is universally recognized and accepted by industry as having the capability of t
~providing analytical solutions that accurately characterize the l ' local stress, gap, friction effects, and plastic material behavior (if any) that are important for assessing the pipe and U-bolt assembly stress, and the support stability. Id. at 42-43.
L
v., , ~
. l ,
~ ;, .. ,
~
10 -
The objectives of the finite element analysis program were (1)eto determin'e lf the pipe would slip, creating an unstable support conditioh when the hanger supp' ort was subjected to the preload, thermal, pressure and mechanical loads that would be expected in the_ Comanche' Peak hanher assemblies; and (2) to calculate pipe and pipe support stresses that could be expected tobeexperiencedbhtheComanchePeakU-boltsupportassemblies and assess their significance. M . at 44-45.
The results of _the analy's ea reflect that (1) the U-bolt assemblies would behave stably at and even below the low preload values evaluated in the analyses (below those values generally expected in the field) (M. at 45-46); (2) maximum stress in the U-bolt as a result of the worst case load combination evaluated compared favorably with test results and demonstrated that stresses in,the U-bolts will not cause any adverse impact (M. at 46-47); and (3) stresses in piping due to preload values expected
'd in the field in conjunction with other loads imposed will not result in,any adverse impact.
M . at 47-49.
3: Stability of U-bolt. Assemblies From the testing and finite element analyses, the U-bolt /crosspiedeassemblycanperformeffectivelyasaclamp provided that sufficient preload,is established in the U-bolt.
M. at 34, 50 nd 71-73. (It should be noted that a clamp also requires preloading.) Further, if the preload level were insufficient, but present in some amount, the U-bolt support would vibrate, but still be capable of supporting the necessary
/
t
-6 loads, thus behaving " stably." Id. at 34 and 74-75. The results of the finite element analyses support the conclusions of the testing in this regard. Id. at 45-46 and 74-75.
To provide further assurance of acceptable preload values, Applicants will conduct a 100 percent inspection of all cinched down U-bolts on struts or snubbers (a total of 380) . Id. at 34.
At the time of the inspections, to remove questions regarding stability, Applicants will assure that each such U-bolt is torqued to a level at which the assembly will be stable in the absolute truest sense, i.e., no rotation, and axial movement, if any, is toward the strut. Id. As previously noted, the results of the tests conducted for vibration, seismic response, creep and thermal cycling confirm the capability to maintain the stability of the assembly when preloaded to observed values.
- 4. Strosses in the U-bolt I From the results of tests, stresses produced in the U-bolts at CPSES would not adversely impact the U-bolts' capability to function. Id. at 3 6-42, and 50. High stresses in the U-bolts occur only if large preload values are applied (i.e., near the maximum used in the tests) to small diameter U-bolts. Id. Large preload values are generally not present in the plant supports, nor are they needed to assure stability of the supports under seismic excitation. Id . a t 4 0-41. In those instances where high preload torques may be initially present, the characteristic relaxation behavior of the material employed ( A-36) will reduce the preload value, and hence, the stresses in the U-bolt, to l
l
acceptable levels.
Id,. Moreover, tests have demonstrated that there is adequate margin between yield and failure of the U-bolts. Id. For instance, these tests showed that for the 1/2-inch U-bolt employed for the 4-inch specimen, the margin is about 2 to 1. Id. The finite ele.'ent analyses in essence confirmed the results of testing. Id. at 46-47.
To allevaite any concern regarding stress in the U-bolts from preload values exceeding those analyzed, as previously noted, Applicants have committed to a 100 percent inspection program of torques of cinched down U-bolts. Id,. at 75.
- 5. Stresses in the Pipe Testing reflects that the maximum torques to the U-bolt pipe assembiles'can potentially result in high but acceptable local pipe stresses. Id. at 3 5 and 50. The finite element analyses confirm that piping strasses resulting frnn U-bolt assemblies and associated loading will not adversely impact plant sa fety . Id . -
at 47-50.
- 6. ASME Code Provisions While'the ASME Code does not provide any direct quantitative guidance regarding local stresses induced by external attachments such aa u-bolt clamp assemblies, the acceptance criteria established and met by. Applicants in this regard conform with the intent of the ASME Code. I d, . at 50-73.
6 M ,.A
____ l
6-IV. CONCLUSION For the reasons set forth above, Applicants request that the Board grant Applicants' motion for summary disposition.
Respectfully submitted, W
Nicholas S. Reynolds William A. Horin Malcolm H. Philips, Jr.
BISHOP, LIBERMAN, COOK, PURCELL & REYNOLDS 1200 Seventeenth Street, N.W.
Washington, D.C. 20036 (202)857-9817 Counsel for Applicants June 29, 1984 l