Text

7 Docket Number 50-346 I

Licent.e Number NPF-3 Serial Number 1976

/.ttachment Page 5 1

I DESIGN FEATURES i

\\

l DESIGN PRESSURE AND TEMPERATURE

{

5.2.2 The reactor containment building is designed and shall be saintained for l

a maximum internal pressure of 40 psig and a temperature of 264'F.

i 5.3 REACTOR CORE

\\

l FUEL ASSEMBLIES ff-d n te t >A % o,tt a c Q "5.3.1 Thereactorcorerhallcontainih[fuelassemblieswitheachfuel _

i i

i assembly containing 208 fuel rods clad VAth Zircaloy -4 Each fuel rod shall have a nominal active fuel length of 14Linches and contain a maximum total i

j,veightof2500gramsuranium.

Reload fs.1 shall be similar in physical design ;

Lto the initial core loading and shall have a maximum enrichment of 3.8 vei fgh j

~~~

percent U-2

~

CONTROL RODS I

5.3.2 The reactor core shall contain 53 safety and regulating and 8 axial power shaping (APSR) control rods.

The safety and regulating control rods shall contain a nominal.134 inches of absorber material. The nominal values of absorber material shall be 80 percent silver, 15 percent indium and 5 percent cadsiva. All control reds shall be clad with stainless steel. tubing. The APSRs shall or.tain a nominal 63 inches of absorber material at their lover ends. The r.bsorber material for the APSRs shall be 100 percent Inconel-600.

j r

5.4 REACTOR COOLANT SYSTEM i

f DESIGN PRESSURE AND TEMPERATURE 5.4.1 The reactor coolant synten is designed and shall be maintained i

l.

a.

In accordance with the code requirements specified in Section 5.2 of i

l the FSAR, with allowance for normal degradation pursuant to applicable l

l Surveillance Requirements, f

l b.

For a. pressure of 2500 psig, and c.

For a temperature of 650'F, except for the pressurizer and pressurizer i

surge line which is 670'F.

I l

DAVIS-BESSE, UNIT 1 54 Amendment No. ZZ. 19.113.1 %

9109040251 910929 I35 fDR ADOCK 05000346 PDR

Docket Number 50-346 License Numbet NPF-3 Serial Number 1976 Attachment Page 6 Current Vording:

5.3.1 The reactor core shall contain 177 fuel assemblies with each fuel assembly containing 208 fuel rods clad with Zircaloy-4.

rod shall have a nominal active fuel length of 144 inches and contain a Each fuel maximum total veight of 2500 grams uranium.

Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrichment of 3.8 veight percent U-235.

Proposed Votding:

5.3.1 The reactor shall contain 177 fuel assemblics.

shall consist of a matrix of Zircaloy clad fuel rods with an initialEach assembly composition of natural or slightly enriched uranium dioxide (00 ) as fuel material, vith a maximum enrichment of 3.8 veight percent U-235.

7 Limited substitutions of stainless steel filler tods for fuel rods accordance with approved applications of fuel rod configurations, may in be used.

Fuel assemblies shall be limited to those fuel designs that have been analyzed with applicable NRC Stati approved codes and methods and shown by tests or analyses to comply with all fuel safety design bases.

Each fuel rod shall have a nominal active fuel length of 144 inchus and shall contain a maximum total veight of 2500 grams uranium I

r

__m.

-I