MONTHYEARNPL-99-0565, TS Change Request 201 to Licenses DPR-24 & DPR-27,revising Tech Specs 15.3.1.A.3,15.3.3..A & 15.3.3.C for Consistency1999-10-0505 October 1999 TS Change Request 201 to Licenses DPR-24 & DPR-27,revising Tech Specs 15.3.1.A.3,15.3.3..A & 15.3.3.C for Consistency NPL-99-0446, Application for Amends to Licenses DPR-24 & DPR-27,removing Word Plasma from TS 15.3.5 Re Discussion of Type of Display Monitor for sub-cooling Info in CR & Removing Discussion from TS 15.3.7 Re EDG Inoperability1999-08-0404 August 1999 Application for Amends to Licenses DPR-24 & DPR-27,removing Word Plasma from TS 15.3.5 Re Discussion of Type of Display Monitor for sub-cooling Info in CR & Removing Discussion from TS 15.3.7 Re EDG Inoperability NPL-99-0405, Suppl 2 to TS Change Request 211,transmitting Text That Will Be Relocated to Pbnp FSAR with Respect to Manager Supervisory Staff Requirements.Suppl Provided Based on Comments Fromqa Branch of NRC1999-07-15015 July 1999 Suppl 2 to TS Change Request 211,transmitting Text That Will Be Relocated to Pbnp FSAR with Respect to Manager Supervisory Staff Requirements.Suppl Provided Based on Comments Fromqa Branch of NRC NPL-99-0386, Application for Amends to Licenses DPR-24 & DPR-27, Respectively,Removing Ifba Enrichment Curve Methodology1999-07-0101 July 1999 Application for Amends to Licenses DPR-24 & DPR-27, Respectively,Removing Ifba Enrichment Curve Methodology NPL-99-0369, Application for Amends to Licenses DPR-24 & DPR-27 to Reflect Required Changes to TS as Result of Using Upgraded Fuel at plant.Non-proprietary,WCAP-14788 & Proprietary WCAP- WCAP-14787 Repts Encl.Proprietary Rept Withheld1999-06-22022 June 1999 Application for Amends to Licenses DPR-24 & DPR-27 to Reflect Required Changes to TS as Result of Using Upgraded Fuel at plant.Non-proprietary,WCAP-14788 & Proprietary WCAP- WCAP-14787 Repts Encl.Proprietary Rept Withheld NPL-99-0337, To TS Change Request 211,reflecting Administrative Changes in Sections 15.6 & 15.7 by Changing Titles,Increasing Min Operating Crew Shift Staffing & Deleting Duty & Call Superintendent Function1999-06-0909 June 1999 To TS Change Request 211,reflecting Administrative Changes in Sections 15.6 & 15.7 by Changing Titles,Increasing Min Operating Crew Shift Staffing & Deleting Duty & Call Superintendent Function NPL-99-0206, TS Change Request 212 to Licenses DPR-24 & DPR-27,updating References in TS to Reflect Relocation of Referenced Info in UFSAR1999-04-12012 April 1999 TS Change Request 212 to Licenses DPR-24 & DPR-27,updating References in TS to Reflect Relocation of Referenced Info in UFSAR NPL-99-0057, Application for Amends to Licenses DPR-24 & DPR-27,revising TS 15.6 & 15.7 to Reflect Proposed Administrative Control Changes1999-01-29029 January 1999 Application for Amends to Licenses DPR-24 & DPR-27,revising TS 15.6 & 15.7 to Reflect Proposed Administrative Control Changes NPL-98-0766, Application for Amends to Licenses DPR-24 & DPR-27,revising TS to Ensure 4 Kv Bus Undervoltage Input to Reactor Trip Is Controlled IAW Design & Licensing Basis for Facility1998-10-0707 October 1998 Application for Amends to Licenses DPR-24 & DPR-27,revising TS to Ensure 4 Kv Bus Undervoltage Input to Reactor Trip Is Controlled IAW Design & Licensing Basis for Facility NPL-98-0586, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Section 15.4.1 by Removing Requirement to Check Environ Monitors on Monthly Basis1998-10-0505 October 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Section 15.4.1 by Removing Requirement to Check Environ Monitors on Monthly Basis NPL-98-0768, Application for Amends to Licenses DPR-24 & DPR-27,adding Notation Definition Contained in TS Table 15.4.1-1, Min Frequencies for Checks,Calibrations & Tests of Instrument Channels, Per NUREG-14311998-09-28028 September 1998 Application for Amends to Licenses DPR-24 & DPR-27,adding Notation Definition Contained in TS Table 15.4.1-1, Min Frequencies for Checks,Calibrations & Tests of Instrument Channels, Per NUREG-1431 NPL-98-0759, Tech Spec Change Request 209,amending Licenses DPR-24 & DPR-27,removing Explicit Testing Requirements of TS Section 15.4.13, Shock Suppressors (Snubbers)1998-09-23023 September 1998 Tech Spec Change Request 209,amending Licenses DPR-24 & DPR-27,removing Explicit Testing Requirements of TS Section 15.4.13, Shock Suppressors (Snubbers) L-98-613, Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability1998-07-30030 July 1998 Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability NPL-98-0613, Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability1998-07-30030 July 1998 Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability NPL-98-0431, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl1998-05-28028 May 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl L-98-431, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl1998-05-28028 May 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl NPL-98-0303, TS Change 205 to License DPR-27,revising Schedule for Implementing Boron Concentration Changes Related to Planned Conversion of Unit 2 to 18-month Fuel Cycles1998-05-15015 May 1998 TS Change 205 to License DPR-27,revising Schedule for Implementing Boron Concentration Changes Related to Planned Conversion of Unit 2 to 18-month Fuel Cycles NPL-98-0146, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Sections 15.3.6, Containment Sys Bases, 15.3.12, CR Emergency Filtration Including bases,15.4.4, Containment Tests bases,15.4.11, CR Emergency...1998-02-26026 February 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Sections 15.3.6, Containment Sys Bases, 15.3.12, CR Emergency Filtration Including bases,15.4.4, Containment Tests bases,15.4.11, CR Emergency... NPL-97-0484, TS Change Request 199,consisting of Application for Amends to Licenses DPR-24 & DPR-27,removing Requirement in TS to Perform Containment Integrated Leak Rate 60-months from Previous Test1997-08-14014 August 1997 TS Change Request 199,consisting of Application for Amends to Licenses DPR-24 & DPR-27,removing Requirement in TS to Perform Containment Integrated Leak Rate 60-months from Previous Test NPL-97-0315, Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 11997-06-0303 June 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 1 NPL-97-0249, Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 11997-05-0909 May 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 1 NPL-97-0167, Application for Amends to Licenses DPR-24 & DPR-27, Eliminating Provisions for Operation of Units at Below 3.5% Rated Power W/Only One RCP1997-04-14014 April 1997 Application for Amends to Licenses DPR-24 & DPR-27, Eliminating Provisions for Operation of Units at Below 3.5% Rated Power W/Only One RCP NPL-97-0166, Application for Amends to Licenses DPR-24 & DPR-27,changing Title of Corporate Officer Responsible for Nuclear Operations from Vice President-Nuclear Power, to Chief Nuclear Officer Per TS Section 15.6.2.1.c1997-04-14014 April 1997 Application for Amends to Licenses DPR-24 & DPR-27,changing Title of Corporate Officer Responsible for Nuclear Operations from Vice President-Nuclear Power, to Chief Nuclear Officer Per TS Section 15.6.2.1.c L-97-005, Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray, to Incorporate Outage Times Similar to NUREG-1431,Rev 11997-02-13013 February 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray, to Incorporate Outage Times Similar to NUREG-1431,Rev 1 ML20134L9621997-02-12012 February 1997 TS Change Request 196 to Licenses DPR-24 & DPR-27, Respectively,Relocating Turbine Overspeed Protection Surveillances,Limiting Conditions for Operation (Lcos),Per NRC GL 95-10 ML20134A3581997-01-24024 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting Storage of Fuel Assemblies of Higher Enrichment than Currently Authorized ML20134A3061997-01-21021 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting to Update References to 10CFR20 in TS Section 15.6.11, Radiation Protection Program ML20133N3961997-01-16016 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting Boron Concentration Changes to Support 18-month Fuel Cycles ML20132C3631996-12-12012 December 1996 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Auxiliary Cooling Sys,Air Recirculation Fan Coolers & Containment Spray, Per NUREG-1431,Rev 1 ML20129F1591996-09-30030 September 1996 Application for Amends to Licenses DPR-24 & DPR-27 for Plant,Units 1 & 2 to Modify TS Section 15.3.3, ECCS, Auxiliary Cooling Sys,Air Recirculation Fan Coolers & Containment Spray, to Incorporate AOT ML20129C0651996-09-19019 September 1996 Application for Amends to Licenses DPR-24 & DPR-27,revising Seection 15.3.15, Overpressure Mitigating Sys & Section 15.3.1, Rcs. Calculation 96-0182,Rev 1 Which Determined Acceptable LTOP Setpoint for Plant,Encl ML20117D2571996-08-22022 August 1996 TS Change Request 190 to Licenses DPR-24 & DPR-27,reflecting Licensed Power Level for Plant ML20116N1311996-08-15015 August 1996 Application for Amends to Licenses DPR-24 & DPR-27, Supplementing TS Change Request 170,modifying TS 15.3.10, Control Rod & Power Distribution Limits & TS 15.4.1 Operational Safety Review ML20112F7291996-06-0404 June 1996 TS Change Request 188 to Licenses DPR-24 & DPR-27,modifying TS 15.2.3, Limiting Safety Sys Settings & Protective Instrumentation & 15.5.3, Design Features - Reactor ML20117K1831996-06-0404 June 1996 TS Change Request 189 to Licenses DPR-24 & DPR-27,modifying TS to Maintain Safety Margin for Unit 2 W/Replacement Sgs. Util Scheduled to Replace SGs in Unit 2 During Fall 1996 Refueling Outage ML20112E2191996-05-29029 May 1996 Application for Amends to Licenses DPR-24 & DPR-27,revising Section 15.4.4,Containment Tests,Section 15.1, Definitions, 15.3.6, Containment System, & 15.6, Administrative Controls ML20108D1461996-04-29029 April 1996 TS Change Request 173 to Application for Amends to Licenses DPR-24 & DPR-27,respectively,removing Fire Protection Requirements from TSs & Incorporating Requirements Into Fire Protection Evaluation Rept,Per GL 88-12 ML20107N1951996-04-24024 April 1996 Application for Amends to Licenses DPR-24 & DPR-27,removing Items Identified in GLs 89-01 & 95-10 as Being Procedural Details from Pbnp Rets,Section 15.7 & Relocating to Appropriate Documents ML20100L3791996-02-27027 February 1996 Application for Amends to Licenses DPR-24 & DPR-27, Respectively,Consisting of TS Change 186,modifying TS Section 15.4.4, Containment Tests, Spec I.C.1 to State That Type a Tests Be Conducted Per 10CFR50,App J ML20097D6691996-02-0808 February 1996 Application for Amends to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 170,modifying TS 15.3.10, Control Rod & Power Distribution Limits & TS 15.4.1, Operational Safety Review ML20095F7521995-12-13013 December 1995 Application for Amends to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 185 Revising TS to Implement COLR in Accordance W/Gl 88-16, Removal of Cycle-Specific Parameter Limits... & WCAP-14483, ...Expanded Colr ML20094R5061995-11-29029 November 1995 Application for Amends to Licenses DPR-24 & DPR-27 Consisting of Suppl to Change Request 180,modifying 4.16 Kv Degraded voltage,4.16 Kv Loss of Voltage & 480 V Loss of Voltage Protection Functions Setting Limits ML20094M9721995-11-17017 November 1995 Application for Amends to Licenses DPR-24 & DPR-27,revising Health Physics Manager Qualifications ML20094H4811995-11-0909 November 1995 TS Change Request 184 to Licenses DPR-24 & DPR-27,modifying TS Section 15.4.2, ISI & Testing of Safety Class Components, to Incorporate F* SG Tube Repair Criterion. Proprietary B&W Rept Encl.Proprietary B&W Rept Withheld ML20094D3041995-10-23023 October 1995 Application for Amends to Licenses DPR-24 & DPR-27,changing Licensee Name to Wisconsin Energy Co (Wec),In Support of Pending Merger Between NSP & WEC ML20093K1091995-10-19019 October 1995 Application for Amend to Licenses DPR-24 & DPR-27,revising Modified TS 15.3.1.G, Operational Limitation, Spec 3.b,to Reduce RCS Raw Measured Total Flow Rate Limit by 4000 Gpm for Unit 2 ML20092H0071995-09-13013 September 1995 Application for Amend to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 181,revising TS Section 15.3.1.G.3 Re RCS Raw Measured Total Flow Rate.W/O TS ML20085N6961995-06-23023 June 1995 Application for Amend to Licenses DPR-24 & DPR-27,consisting of Change Request 164,modifying TS 15.3.0, General Considerations, to Incorporate Requirements Similar to NUREG-1431 ML20083B0051995-05-0202 May 1995 Application for Amends to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 172,modifying TS Section 15.4.1, Operational Safety Review ML20082R8761995-04-27027 April 1995 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Section 15.3.5, Instrumentation Sys 1999-08-04
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARNPL-99-0565, TS Change Request 201 to Licenses DPR-24 & DPR-27,revising Tech Specs 15.3.1.A.3,15.3.3..A & 15.3.3.C for Consistency1999-10-0505 October 1999 TS Change Request 201 to Licenses DPR-24 & DPR-27,revising Tech Specs 15.3.1.A.3,15.3.3..A & 15.3.3.C for Consistency ML20211A7561999-08-11011 August 1999 Amends 190 & 195 to Licenses DPR-24 & DPR-27,respectively, Revising Sections 15.6 & 15.7 of Pbnp,Units 1 & 2.Rev Reflects Personnel Title Changes,Increases Min Operating Crew Shift Staffing & Rev to Procedure Review NPL-99-0446, Application for Amends to Licenses DPR-24 & DPR-27,removing Word Plasma from TS 15.3.5 Re Discussion of Type of Display Monitor for sub-cooling Info in CR & Removing Discussion from TS 15.3.7 Re EDG Inoperability1999-08-0404 August 1999 Application for Amends to Licenses DPR-24 & DPR-27,removing Word Plasma from TS 15.3.5 Re Discussion of Type of Display Monitor for sub-cooling Info in CR & Removing Discussion from TS 15.3.7 Re EDG Inoperability NPL-99-0405, Suppl 2 to TS Change Request 211,transmitting Text That Will Be Relocated to Pbnp FSAR with Respect to Manager Supervisory Staff Requirements.Suppl Provided Based on Comments Fromqa Branch of NRC1999-07-15015 July 1999 Suppl 2 to TS Change Request 211,transmitting Text That Will Be Relocated to Pbnp FSAR with Respect to Manager Supervisory Staff Requirements.Suppl Provided Based on Comments Fromqa Branch of NRC NPL-99-0386, Application for Amends to Licenses DPR-24 & DPR-27, Respectively,Removing Ifba Enrichment Curve Methodology1999-07-0101 July 1999 Application for Amends to Licenses DPR-24 & DPR-27, Respectively,Removing Ifba Enrichment Curve Methodology NPL-99-0369, Application for Amends to Licenses DPR-24 & DPR-27 to Reflect Required Changes to TS as Result of Using Upgraded Fuel at plant.Non-proprietary,WCAP-14788 & Proprietary WCAP- WCAP-14787 Repts Encl.Proprietary Rept Withheld1999-06-22022 June 1999 Application for Amends to Licenses DPR-24 & DPR-27 to Reflect Required Changes to TS as Result of Using Upgraded Fuel at plant.Non-proprietary,WCAP-14788 & Proprietary WCAP- WCAP-14787 Repts Encl.Proprietary Rept Withheld NPL-99-0337, To TS Change Request 211,reflecting Administrative Changes in Sections 15.6 & 15.7 by Changing Titles,Increasing Min Operating Crew Shift Staffing & Deleting Duty & Call Superintendent Function1999-06-0909 June 1999 To TS Change Request 211,reflecting Administrative Changes in Sections 15.6 & 15.7 by Changing Titles,Increasing Min Operating Crew Shift Staffing & Deleting Duty & Call Superintendent Function ML20206A4951999-04-23023 April 1999 Amends 189 & 194 to Licenses DPR-24 & DPR-27,respectively, Change TS to Provide Specific Numerical Setpoint Limits for Rt,Rcp Trip & Auxiliary Feedwater Initiation on Loss of Power to 4 Kv Buses NPL-99-0206, TS Change Request 212 to Licenses DPR-24 & DPR-27,updating References in TS to Reflect Relocation of Referenced Info in UFSAR1999-04-12012 April 1999 TS Change Request 212 to Licenses DPR-24 & DPR-27,updating References in TS to Reflect Relocation of Referenced Info in UFSAR ML20207L3351999-03-0202 March 1999 Amends 187 & 192 to Licenses DPR-24 & DPR-27,respectively, Modifying TS 15.4.1, Operational Safety Review, by Removing Requirement to Check Environ Monitors on Monthly Basis ML20207D5621999-03-0101 March 1999 Amends 186 & 191 to Licenses DPR-24 & DPR-27,respectively,to Clarify Notation Definition of Refueling Interval, R, in TS Table 15.4.1-1, Minimum Frequencies for Checks, Calibrations & Tests of Instrument Channels NPL-99-0057, Application for Amends to Licenses DPR-24 & DPR-27,revising TS 15.6 & 15.7 to Reflect Proposed Administrative Control Changes1999-01-29029 January 1999 Application for Amends to Licenses DPR-24 & DPR-27,revising TS 15.6 & 15.7 to Reflect Proposed Administrative Control Changes NPL-98-0766, Application for Amends to Licenses DPR-24 & DPR-27,revising TS to Ensure 4 Kv Bus Undervoltage Input to Reactor Trip Is Controlled IAW Design & Licensing Basis for Facility1998-10-0707 October 1998 Application for Amends to Licenses DPR-24 & DPR-27,revising TS to Ensure 4 Kv Bus Undervoltage Input to Reactor Trip Is Controlled IAW Design & Licensing Basis for Facility NPL-98-0586, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Section 15.4.1 by Removing Requirement to Check Environ Monitors on Monthly Basis1998-10-0505 October 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Section 15.4.1 by Removing Requirement to Check Environ Monitors on Monthly Basis NPL-98-0768, Application for Amends to Licenses DPR-24 & DPR-27,adding Notation Definition Contained in TS Table 15.4.1-1, Min Frequencies for Checks,Calibrations & Tests of Instrument Channels, Per NUREG-14311998-09-28028 September 1998 Application for Amends to Licenses DPR-24 & DPR-27,adding Notation Definition Contained in TS Table 15.4.1-1, Min Frequencies for Checks,Calibrations & Tests of Instrument Channels, Per NUREG-1431 NPL-98-0759, Tech Spec Change Request 209,amending Licenses DPR-24 & DPR-27,removing Explicit Testing Requirements of TS Section 15.4.13, Shock Suppressors (Snubbers)1998-09-23023 September 1998 Tech Spec Change Request 209,amending Licenses DPR-24 & DPR-27,removing Explicit Testing Requirements of TS Section 15.4.13, Shock Suppressors (Snubbers) NPL-98-0613, Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability1998-07-30030 July 1998 Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability L-98-613, Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability1998-07-30030 July 1998 Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability ML20236U7171998-07-21021 July 1998 Amend 190 to License DPR-27,revising Schedule for Implementing Boron Concentration Changes from Refueling Outage 24 to Refueling Outage 23 for Planned Conversion of Unit 2 to 18-month Fuel Cycles ML20236T1731998-07-17017 July 1998 Amends 185 & 189 to Licenses DPR-24 & DPR-27,respectively, Revising TS Table 15.4.1-1, Min Frequencies for Checks, Calibrs & Tests of Instrument Channels, to Change Test Frequency of Containment Hrrm,Revise Note 7 & Item 36 ML20236S0111998-07-13013 July 1998 Amends 184 & 188 to Licenses DPR-24 & DPR-27,respectively, Revising TS Section 15.7, RETS, Sections 15.7.3,15.3.4 & 15.7 of RETS Were Moved to licensee-controlled Documents Consistent W/Gl 89-01 L-98-431, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl1998-05-28028 May 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl NPL-98-0431, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl1998-05-28028 May 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl NPL-98-0303, TS Change 205 to License DPR-27,revising Schedule for Implementing Boron Concentration Changes Related to Planned Conversion of Unit 2 to 18-month Fuel Cycles1998-05-15015 May 1998 TS Change 205 to License DPR-27,revising Schedule for Implementing Boron Concentration Changes Related to Planned Conversion of Unit 2 to 18-month Fuel Cycles ML20217K4511998-03-24024 March 1998 Amends 183 & 187 to Licenses DPR-24 & DPR-27,respectively, Allowing Health Physicist to Fulfill TS Requirements Previously Specified for Health Physics Manager ML20248L8611998-03-17017 March 1998 Amends 182 & 186 to Licenses DPR-24 & DPR-27,respectively, Revising Section 15.6.11, Radiation Protection Program, Ref to 10CFR20 NPL-98-0146, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Sections 15.3.6, Containment Sys Bases, 15.3.12, CR Emergency Filtration Including bases,15.4.4, Containment Tests bases,15.4.11, CR Emergency...1998-02-26026 February 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Sections 15.3.6, Containment Sys Bases, 15.3.12, CR Emergency Filtration Including bases,15.4.4, Containment Tests bases,15.4.11, CR Emergency... ML20198T0731997-09-29029 September 1997 Corrected TSs Pages 15.4.2-5 & 15.6.12-1 to Amends 181 & 185,respectively.Amends Issued W/Typographical Error on Pages ML20217D6951997-09-29029 September 1997 Amends 181 & 185 to Licenses DPR-24 & DPR-27,respectively, Changes TSs Re Containment Integrated Leak Rate Testing ML20236R9451997-09-23023 September 1997 Amends 180 & 184 to Licenses DPR-24 & DPR-27,respectively, Changing Amounts of Boric Acid in Refueling Water Storage Tanks,Boric Acid Storage Tanks & Safety Injection Accumulators & Increase Lowest Permissible Concentration ML20210S9641997-09-0404 September 1997 Amends 179 & 183 to Licenses DPR-24 & DPR-27,respectively,to Revise TS 15.5.4, Fuel Storage, to Increase Fuel Assembly Enrichment Limits to 5.0 Weight Percent ML20216G5511997-09-0303 September 1997 Amends 178 & 182 to Licenses DPR-24 & DPR-27,respectively, Revising TS 15.3.1, Reactor Coolant Sys, to Eliminate Provisions for at Power Operation W/Single Reactor Coolant Pump ML20210P9981997-08-25025 August 1997 Amends 177 & 181 to Licenses DPR-24 & DPR-27,respectively, Revising TS Sections 15.6.2, Organization, TS 15.6.5.1, Managers Supervisory Staff, TS 15.6.6, Reportable Event Action & TS 15.6.7 NPL-97-0484, TS Change Request 199,consisting of Application for Amends to Licenses DPR-24 & DPR-27,removing Requirement in TS to Perform Containment Integrated Leak Rate 60-months from Previous Test1997-08-14014 August 1997 TS Change Request 199,consisting of Application for Amends to Licenses DPR-24 & DPR-27,removing Requirement in TS to Perform Containment Integrated Leak Rate 60-months from Previous Test ML20217H4171997-08-0606 August 1997 Amends 175 & 179 to Licenses DPR-24 & DPR-27,respectively, Revising Section 3.A of Facility OL from Licensed Power Level of 1,518 MW Thermal to 1,518.5 MW Thermal ML20198F0191997-08-0606 August 1997 Amends 176 & 180 to Licenses DPR-24 & DPR-27,respectively, Relocating Turbine Overspeed Protection Specs,Limiting Conditions for Operation,Srs & Associated Bases from TS Section 15.3.4 to FSAR ML20148U4631997-07-0101 July 1997 Amends 173 & 177 to Licenses DPR-24 & DPR-27,respectively, Revising Listed TSs & Definitions for Both Units to Incorporate Listed Changes to Facility Into TS & FSAR NPL-97-0315, Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 11997-06-0303 June 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 1 NPL-97-0249, Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 11997-05-0909 May 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 1 NPL-97-0167, Application for Amends to Licenses DPR-24 & DPR-27, Eliminating Provisions for Operation of Units at Below 3.5% Rated Power W/Only One RCP1997-04-14014 April 1997 Application for Amends to Licenses DPR-24 & DPR-27, Eliminating Provisions for Operation of Units at Below 3.5% Rated Power W/Only One RCP NPL-97-0166, Application for Amends to Licenses DPR-24 & DPR-27,changing Title of Corporate Officer Responsible for Nuclear Operations from Vice President-Nuclear Power, to Chief Nuclear Officer Per TS Section 15.6.2.1.c1997-04-14014 April 1997 Application for Amends to Licenses DPR-24 & DPR-27,changing Title of Corporate Officer Responsible for Nuclear Operations from Vice President-Nuclear Power, to Chief Nuclear Officer Per TS Section 15.6.2.1.c ML20138M0481997-02-20020 February 1997 Amends 172 & 176 to Licenses DPR-24 & DPR-27,respectively, Revising RCS Temp Below Which LTOP Sys & Pressurizer PORVs Shall Be Operable,Modify Requirement to Limit Operation of High Pressure Injection Pump from RCS Cold Leg Temp L-97-005, Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray, to Incorporate Outage Times Similar to NUREG-1431,Rev 11997-02-13013 February 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray, to Incorporate Outage Times Similar to NUREG-1431,Rev 1 ML20134L9621997-02-12012 February 1997 TS Change Request 196 to Licenses DPR-24 & DPR-27, Respectively,Relocating Turbine Overspeed Protection Surveillances,Limiting Conditions for Operation (Lcos),Per NRC GL 95-10 ML20134H0231997-02-0505 February 1997 Corrected Tech Spec Pages to Amends 171 & 175 to Licenses DPR-24 & DPR-27.TS Page 4 of 5 Issued with Part of Text Illegible & Page 5 of 5 Inadvertently Omitted ML20134A3581997-01-24024 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting Storage of Fuel Assemblies of Higher Enrichment than Currently Authorized ML20134A1111997-01-23023 January 1997 Corrected TS Pages for Amends 171 & 175 to Licenses DPR-24 & DPR-27,respectively ML20134A3061997-01-21021 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting to Update References to 10CFR20 in TS Section 15.6.11, Radiation Protection Program ML20133N3961997-01-16016 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting Boron Concentration Changes to Support 18-month Fuel Cycles ML20133N4231997-01-16016 January 1997 Amends 171 & 175 to Licenses DPR-24 & DPR-27,respectively, Revising TS Section 15.3.10, Control Rod & Power Distribution Limits 1999-08-04
[Table view] |
Text
>
g:
v
+
c p
1 4
y Wisconsin Electnc POWER COMPANY 23iw Michgan. PO Bok 2046, MAvaukao.WI S32012046 (414)2202345-VPNPD-9 4- 0 33 30CFR50.4
.NRC-94-026 10CFR50.90 March 29, 1994 a
Document Control Desk
-U..S.
NUCLEAR REGULATORY COMMISSION Mail Station F1-137 Washington, DC 20555 Gentlemen:
DOCKETS 50-266 AND 50-301 ROST BENEFICIAL LICENSING ACTION TECHNICAL SPECIFICATIONS CHANGE REOUEST 165 BORIC ACID CONCENTRATION REDUCTIO 4
. POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 In accordance with the requirements of 10 CFR-50.4 and 50.90,
-Wisconsin Electric Power Company (Licensee) hereby requests amendments to Facility Operating Licenses DPR-24 and DPR-27 for Point l Beach Nuclear Plant- (PBNP), Units 1 and 2, respectively, to incorporate changes to the plant Technical' Specifications.
The proposed. changes modify Technical Specifications section 15.3.2,
" Chemical and Volume Control-System,"~by, eliminating the necessity.
of high concentration boric acid and removing the. operability.
- requirements for the associated heat tracing.; The basis for; Section 15~.3.2 and applicable surveillancesJin_ Table.15.4.1-2 are i
also being revised to support the above changes.
The proposed specifications are similar to-those of: Turkey Point Nuclear Plant (Amendments 144/139 dated; July 16,.1991) and-R..E. Ginna Nuclear Power Plant (Amendment 57. dated-December'7, 1993).
Marked-up Technical; Specifications pages,: a safety 7 evaluation, and aLno significant hazards consideration are enclosed.
D The proposed changes will provide cost savings of at least $1'.2 million.through the end of the~ current operating. licenses off both-units.due to reduced boric acid heat" tracing: power; consumption and maintenance. 'Because these cost savings will beLachieved without'a-reduction'in plant safety, we are submittingfthis. change as a high priority Cost-Beneficial Licensing-Action-(CBLA).
4 L
000057
'9404080077-940429 T
.'k PDR ADOCK 05000266
)--
)
P.
PDR A suwiuyof&wsinEwgQ>gwalkr 3
e-Document Control Desk March 29, 1994 Page 2 DESCRIPTION OF CURRENT LICENSE CONDITION The PBNP concentrated boric acid (11.5-12.5_ weight percent) system consists of three 5000 gallon boric acid storage tanks (BASTS) and four boric acid transfer pumps (two per unit), along with their associated piping, valves, and heat tracing circuitry.
One BAST is normally aligned to each unit and the third BAST may be used as.a swing tank and aligned to either unit.
Concentrated boric acid may be injected into the reactor coolant system with the charging pumps through either the emergency, manual, or boric acid blender flow paths, or with the safety injection (SI) pumps.
One 275,000 gallon refueling water storage tank (RWST) per unit is also available as a sourne of 2000 ppm boric acid.
Technical Specifications Section 15.3.2, " Chemical and Volume Control System," defines the conditions of the chemical and_ volume control system (CVCS) necessary to insure safe reactor operation.
Section 15.3.2 presently requires a minimum of 2000 gallons of 211.5 weight percent boric acid solution to be available in the aligned BAST for each operating unit.
This quantity ensures sufficient boric acid is available to bring the unit to cold shutdown.
In order to prevent boric acid precipitation at that concentration, the solution must be maintained at a minimum temperature of 145 F.
Table 15.4.1-2, " Minimum Frequencies For Equipment and Sampling Tests," describes the surveillances and tests to be performed on various equipment throughout the plant.
The proposed changes to the Technical Specifications requirements for the CVCS do not affect the Technical Specifications requirements for the emergency core cooling system (ECCS).
The R
original design of the high head (SI) system used the BASTS as its initial suction source.
Analyses and evaluations performed by-_
Westinghouse and Wisconsin Electric support our 10 CFR 50.59 Safety Evaluation justifying the design change to use the RWST as the initial suction source of SI fluid rather than the BAST.
DESCRIPTION OF PROPOSED CHANGES 1.
Existing Specifications 15.3.2.B, C,
and D are revised to specify boron injection flow path operability for reactor criticality as follows:
u
~
a
4 Document Control Desk March 29, 1994 Page 3 15.3.2 B.
A reactor shall not be taken critical unless the following chemical and volume control system conditions are met:
1.
A minimum of two charging pumps for that reactor shall be operable.
2.
System piping and valves shall be operable to the extent of establishing two flow paths from the boric acid tank (s) and/or the refueling water storage tank to the reactor coolant system.
3.
If the boric acid tank (s) is required to comply with Specification B.2 above:
a.
One boric acid transfer pump shall be operable
)
per flow path from the boric acid tank (s) with one of the BAST flow paths lined up to supply boric acid to the applicable reactor, and b.
The boric acid concentration, minimum volume, and solution temperature'shall satisfy the y
requirements of Table 15.3.2-1.
-l C.
A second reactor shall not be taken critical with one reactor already critical unless the following chemical j
and volume control system conditions are met:
1.
A minimum of two charging pumps for that reactor-shall be operable, j
i 2.
System piping and valves shall be operable to the extent of establishing two flow paths from the' boric acid tank (s) and/or the~ refueling water storage tank (s) to each reactor coolant system.
3.
If the boric acid' tank (s) is required to comply with Specification C.2 above:
a.
One boric acid transfer pump shall be operable per flow path from the borickacid tank (s) with one of the BAST flow paths lined up to_ supply boric acid to the applicable reactor, and i
L
1 1
t Document Control Desk March 29, 1994 Page 4 1
b.
The boric acid concentration, minimum volume, and solution temperature shall satisfy the requirements of Table 15.3.2-1.
D.
During power operation, the requirements of 15.3.2.B and C may be modified to allow the following components to be inoperable for a specified time.
If the system is not restored to meet the requirements of 15.3.2.B or C within the time period specified, the appropriate reactor (s),
except as otherwise noted, shall be placed in the hot shutdown condition within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and borated to a shutdown margin equivalent of at least 1.0% delta k/k at cold shutdown, no xenon conditions.
If the requirements of 15.3.2.B or C are not satisfied within an additional 7 days, the appropriate reactor (s) shall be placed in the cold shutdown condition within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
1.
One of the two operable charging pumps associated
';ith an operating reactor may be removed from service provided a charging pump associated with that reactor is restored to operable status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.
2.
One of the two boron injection flow paths specified in B.2 or C.2 may be out of service provided two boron injection flow paths are restored to operable status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.
3.
One of the boric acid transfer pumps designated in B.3 or C.3 may be out of service provided a boric acid transfer pump is restored to operable status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.
2.
To support the above changes, the basis for Section 15.3.2 is being replaced with the following description:
The chemical and volume control system provides control of the reactor coolant system boron inventory.
This is normally accomplished by using one or more charging pumps in series with one of the two boric acid transfer pumps.
Above cold shutdown conditions, a minimum of two boron injection flow paths are required per unit to insure functional capability in the event that an assumed single active failure renders one of the flow paths inoperable.
The boration volume available through any flow path is sufficient to provide the required shutdown margin at cold shutdown, xenon-free conditions from any expected normal operating condition.
The maximum volume
t Document Control Desk March 29, 1994 Page 5 requirement is associated with boration from just critical, hot zero or full power, peak xenon with control rods at the insertion limit, to xenon-free, cold shutdown with the highest worth control rod assembly fully withdrawn.
This requires approximately 24,100 gallons of 2000 ppm borated water.from the refueling water storage tank (RWST) or the concentrations and volumes of borated water specified in Table 15.3.2-1 from the boric acid storage tanks (BASTS).
Available flow paths from the borated water sources to the charging pumps include, but are not limited to, the following:
1)
BASTS via one boric acid transfer pump through the normal makeup flow path to the suction of the charging pumps.
2)
BASTS via one boric acid transfer pump through the emergency boration flow path to the suction of the charging pumps.
3)
RWST via gravity feed through the motor-operated valve to the suction of the charging pumps.
4)
RWST via gravity feed through the manual valve to the suction of the charging pumps."
Available flow paths from the charging pumps to the reactor coolant system include, but are not limited to, the following:
1)
Charging flow path to the RCS Loop A cold leg.
2)
Charging flow path to the RCS Loop B cold leg.
3)
Seal injection flow path to the reactor coolant pumps.
Boration of the RCS may also be accomplished via the two boric acid flow paths from the RWST and BASTS through the safety injection (SI) syste m.
Use of these flow paths requires the RCS to be initially depressurized below the SI pump shutoff head.
The amount of boric acid injection must be sufficient to compensate for the addition of positive reactivity from the decay of xenon after a reactor trip from full' power in order to maintain the required shutdown margin.
This can be accomplished through the operation of one charging pump at minimum speed taking suction from the RWST.
Also, the time required for boric acid injection allows for the local
m t
' Document Control Desk March 29, 1994 Page 6 alignment of manual valves to provide the necessary flow paths.
The quantity of boric acid specified in Table 15.3.2-1 for each concentration is the quantity necessary per reactor relying on the BAST (s) as a borated water source to borate the reactor coolant to the required cold shutdown concentration at any time in core life.
The vclume requirements listed in Table 15.3.2-1 are based on the lower concentration in each range.
The temperature limits specified in Table 15.3.2-1 are required to maintain solution solubility at the upper concentration in each range.
Heat tracing may be used to maintain solution temperature at or above the limits in' Table 15.3.2-1.
If the solution temperature of either the flow path or the BAST (s) is not maintained at or above the minimum temperature specified, the affected flow path must be declared inoperable and the appropriate actions in Specification 15.3.2.D followed.
3.
The BAST boron concentration surveillance in Table 15.4.1-2 is being revised to add an additional surveillance after each BAST concentration change when the BASTS are being relied upon as a source of borated water.
In addition, BAST and boric acid system piping temperatures will be checked daily when the BASTS are being relied upon as a source of borated water to ensure their temperatures are greater than or equal to-the temperature required in proposed Table 15.3.2-1.
The boric acid heat tracing operability surveillance is being deleted.
BASIS AND JUSTIFICATION on March 31, 1992, the level indication on the "B" BAST became inoperable due to boric acid precipitation.
A corrective action resulting from'this condition was to evaluate the possibility of reducing the boric acid concentration to prevent similar operational problems.
The results of our evaluation indicated that a redefinition of the boration paths in Technical Specifications Section 15.3.2 and a boric acid concentration reduction is possible without adding additional storage capacity or other major modifications.
The justification for the additions included in the
" Description of Proposed Changes" section of this letter is located ir the attached safety evaluation.
4
]
r
Document Control Desk March 29, '1994 Page 7 We have determined that the proposed amendments do not involve a significant hazards consideration, authorize a significant change in the types or total amounts of any effluent release, or result in any significant increase in individual or cumulative occupational exposure.
We therefore conclude that the proposed amendments meet the requirements of 10 CFR 51. 22 (c) (9) and that an environmental impact statement or negative declaration and environmental impact appraisal need not be prepared.
As part of our diesel generator addition project, it is necessary to remove the boric acid heat tracing loads from the Unit 1 "B"
train busses for loading concerns.
The new diesel generators will be tied into these busses during the spring 1995 Unit 1 refueling outage.
Therefore, we request that this Technical Specifications Change Request be approved by March 3, 1995.
Please contact us if you have any questions.
Sincerely,
~
f qf Bob Link Vice President Nuclear Power Enclosures copies to NRC Regional Administrator NRC Resident Inspector Public Service Commission of Wisconsin Subscribed [ day and swo.
to be ore me this 3 67.
5 gw
, 1994. /
- u. -
1 u r, e fotary Publid,/ttite of Wis - si My Commidsion expires
)<
)$Y
/
TECHNICAL SPECIFICATIONS CHANGE REOUEST 165 BAFETY EVALUATION INTRODUCTION Wisconsin Electric Power Company (Licensee) is applying for amendments to Facility Operating Licenses DPR-24 and DPR-27 for Point Beach Nuclear Plant, Units 1 and 2.
The proposed changes modify Technical Specifications Section 15.3.2, " Chemical and Volume control System," by decreasing the boric acid storage tank (BAST) boric acid conc" cration and providing a more detailed description of the bo;.
acid injection paths which allows deleting the operability requirements for the boric acid syste.:
heat tracing.
The basis for section 15.3.2 and applicable surveillances in Table 15.4.1-2 are also being revised to support the above changes.
EVALUATION Point Beach Nuclear Plant (PBNP) has historically experienced operational challenges with its boric acid injection system due to boric acid " freeze-ups" caused by failures of our maintenance intensive heat tracing circuits.
The results of our evaluation indicate that boric acid concentration can be reduced to a level where heat tracing is not required to maintain the boric acid solubility.
The applicable general design criteria (GDC) as defined in the PBNP Final Safety Analysis Report (FSAR) are GDCs 28, 29, and 30.
Criterion 28 requires the reactivity control system to be capable of making and holding the core subcritical'from any hot standby or hot operating condition.
Criterion 29 requires one of the reactivity control systems to be capable of making the core subcritical under any anticipated operating condition sufficiently fast to prevent exceeding acceptable fuel damage limits with shutdown margin to assure subcriticality with the most reactive control rod fully withdrawn.
Criterion 30 requires the reactivity control system to be capable of making the core suberitical under credible accident conditions with appropriate margins for contingencies and limiting any subsequent return to power such that there will be no undue risk to the health and safety of the public.
We have determined that these GDCs remain satisfied with the proposed changes.
The original design of the safety injection (SI) system used engineered safety feature control logic to open the valves
.between the boric acid storage tank (BAST) and the suction of the SI pumps when SI was initiated.
This lined up the BAST as the initial suction source of SI fluid.
When the BAST low-low level setpoint was reached, the suction line from the BAST to SI isolated and the valves from the refueling water storage tank (RWST) opened automatically.
Westinghouse WCAP-12602, " Report For Th9 Reduction of SI System Boron Concentration," and a 10 CFR 50.59 Safety Evaluation Report performed by Wisconsin Electric
justifies the design change to use the refueling water storage tank (RWST) as the initial suction source of SI fluid rather than the BAST.
The affected FSAR Chapter 14 accident analyses include the Loss of Coolant Accident (LOCA) events and the Steamline Break (SLB) events.
The LOCA events are affected with respect to the large-break post-LOCA long-term core cooling subcriticality requirement.
The SLB events are affected with respect to core integrity.
The events were analyzed assuming the elimination of the logic which automatically opened the valves in the flow path from the BASTS to the SI pumps upon the receipt of a safety injection signal and assuming SI pump suction from the RWST.
The results show that we remain within the acceptance criteria of the aforementioned.FSAR Chapter 14 accident analyses.
Proposed Specifications 15.3.2.B.2 and C.2 ensure that two flow paths and associated sources of borated water are available to maintain long term subcriticality.
The specified volume of boric acid in proposed Table 15.3.2-1 is that amount which'is sufficient to bring one unit to cold shutdown from any anticipated operating condition assuming the most reactive control rod to be stuck out.
The existing RWST specification continues to meet this requirement.
The amount of boric acid required in the BASTS if they are chosen as the borated water source is dependent on the boric acid concentration.
Our analysis indicates that 300 lb. of stored boron is sufficient for PBNP's annual fuel cycle.
This conclusion has been confirmed by Westinghouse using the BORDER (boron Design Requirements) methodology.
The BORDER methodology is utilized during the Westinghouse reload core design process.
The minimum temperature requirement in proposed Table 15.3.2-1 provides protection against boron precipitation.
The temperatures specified in proposed Table 15.3.2-1 represent the solubility temperature plus 5*F for boric acid concentrations <5 weight percent and the solubility temperature plus 7.8'F for boric acid concentrations 25 weight percent.
The 7.8'F margin corresponds to the present margin for 12.5 weight percent boric acid solution in our current Technical Specifications.
The lower solubility margin below 5 weight percent boric acid solution was chosen for operational flexibility and due to the proximity of the solubility temperatures to ambient. temperature.
The smaller difference between the solubility and ambient temperatures reduces the driving force to cause a boric acid solution temperature change.
Therefore, boric acid solution temperature will be more easily maintained at concentrations <S weight percent and the reduced solubility margin is considered acceptable.
We have also verified via calculation P-93-014 that for a typical fuel cycle (U1R21) and assuming worse-case conditions, the reactor can be maintained subcritical following a reactor trip.
Specifically, the amount of negative reactivity that can be inserted by one charging pump borating at minimum speed using the RWST as its suction source is greater than the positive reactivity added from the decay of xenon.
The proposed increase in the allowable outage times (A0Ts) from 24 to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is based on the low probability of a design basis accident occurring during this period of inoperability and is consistent with NUREG-0452, Revision 4, "St'ndard Technical Specifications for Westinghouse Pressurized %'ter Reactors."
The proposed change to borate to a shutdown margi.
3f at least 1.0%
delta k/k with no xenon at cold shutdown condit_ons compensates for long-term xenon decay and temperature reduction.
The applicable surveillances in Table 15.4.1-2 are being revised to correspond with the elimination of the boric acid heat tracing operability requirements and adds an additional boric acid concentration surveillance after each boric acid concentration change when the BASTS are being relied upon as a source of borated water.
Heat tracing will no longer be required because the boric acid system solubility temperature will generally be maintalued below ambient temperature.
The proposal now specifies the temperature required to maintain boric acid solubility rather than the means of maintaining boric acid solubility.
Therefore, we may employ various means (heat tracing, increase ambient temperature, select alternate flow path (s)) to meet the boric acid system solubility / operability requirement.
Temperatures will be verified locally through the use of existing boric acid system piping and tank temperature indication.
The boric acid system piping low temperature alarm will remain operational in the control room, goNCLUSTONS The proposed revisions will ensure and enhance the safe and reliable operation of Point Beach Nuclear Plant.
j IECHNICAL BPECIFICATIONS CHANGE REOUEST 165 "NO SIG.NIFICANT HAZARDS CONSIDERATION" In accordance with the requirements of 10 CFR 50.91(a), Wisconsin Electric Power Company (Licensee) has evaluated the proposed changes against the standards of 10 CFR 50.92 and has determined j
that the operation of Point Beach Nuclear Plant, Units 1 and 2, y
in accordance with the proposed amendments, does not present a significant hazards consideration.
The analysis of the requirements of 10 CFR 50.92 and the basis for this conclusion are as follows:
1.
Operation of this facility under the proposed Technical Specifications change will not create a significant increase in the probability or consequences of an accident previously evaluated.
Reduced boron concentration in the boric acid storage tank (BAST) i offset by increasing the volume of boric acid solution that must be contained in the tanks.
The heat tracing requirements are used to ensure that the dissolved boric acid is maintained in solution and available for injection into the RCS to adjust core reactivity throughout core life and to meet GDC requirements.
Chemical analyses of boron concentrations of $4.0 weight percent have shown that the boric acid does not crystallize at temperatures above 57aF.
Ambient temperatures in the areas of the primary auxiliary building where these components are located will normally remain above this temperature.
- Hence, heat tracing will no longer be needed for boric acid concentrations with corresponding solubility temperatures less than ambient temperatures.
The proposed Technical Specifications requirements for boron concentration, volume, and temperature of the BASTS and boration paths ensure that the capability to inject boric acid is maintained.
Since the components (and their function) necessary to achieve a safe shutdown have not been changed or modified, this change does not significantly increase the probability or consequences of any accident previously evaluated.
The proposed changes to the boric acid system Technical Specifications requirements for the chemical and volume control system (CVCS) do not affect the requirements for the emergency core cooling system (ECCS).
The original design of the high head safety injection (SI) system used the BASTS as its initial suction source.
Westinghouse WCAP-12602,
" Report For The Reduction of SI System Boron Concentration,"
atM a 10 CFR 50.59 Safety Evaluation Report performed by Wisconsin Electric justifies the design change to use the refueling water storage tank (RWST) as the initial suction source of SI fluid rather than the BAST. ~The affected FSAR Chapter 14 accident analyses include the Loss of Coolant Accident (LOCA) events and the Steamline Break (SLB) events.
The LOCA events are affected with respect to the large-break e
a
);..
post-LOCA long-term core cooling subcriticality requirement.
The SLB. events are affected with respect to core. integrity.
The events were analyzed assuming the elimination of the logic which automatically opened the valves in the flow path from.the BASTS to the SI pumps upon the receipt of a safety injection signal.
The results show that we remain within.
the acceptance criteria of the aforementioned FSAR Chapter 14 accident analyses.
Therefore, the proposed changes will not create a significant increase in the probability or consequences of an accident previously evaluated.
2.
Operation of this facility under the proposed Technical Specifications change will not create the possibility of a new or different kind of accident from any accident previously evaluated.
The reactivity control function of the boron in the CVCS and SI systems is not being changed.
Therefore,-the proposed changes will not create the possibility of a new or different kind of accident from any accident previously evaluated.
3.
Operation of this facility under the proposed Technical Specifications change will not create a significant reduction in a margin of safety.
The intent of the proposed Technical Specifications is to ensure that two independent flow paths from the borated water source (s) (BASTS and/or RWST) to the reactor coolant system are maintained whenever a. unit is taken critical.
This requires that sufficient quantities of boric acid be stored in the tanks, and that this borated water can be delivered to the reactor coolant system when required.
Although we presently require diverse sources of borated water (BAST HDd RWST), the proposed reduction in diversity will be offset by the significant increase in reliability of the boric acid system due to operation with lower boric acid concentrations and, hence, a much lower probability of boron preciyitation and system " freeze-up."
Reducing the boric acid concentration in the BASTS has been compensated for by increasing the required volume of boric acid.
The proposed Technical Specifications requirements for boric acid concentration and volume include the additional specification of minimum temperature that must be maintained to assure boric acid solubility.
The minimum temperature requirement is more appropriate than the requirement for heat tracing because it is a more precise means of verifying and assuring solubility.
Therefore, the proposed boric acid concentration table, which includes the volume and temperature requirements, is an appropriate substitute for the heat tracing requirements.
Although the heat tracing requirement is being eliminated, the boric acid heat tracing
'l b
system will be available during our transition to the lower boric acid concentration to assist in maintaining boric acid system temperature if necessary.
Since our analyses have shown that the existing FSAR Chapter 14 accident. analyses remain bounded under the proposed specifications, the margin' of safety for the plant is not significantly~ reduced.
t i
4 1