@ utoq p
t UNITED STATES j
NUCLEAR RESULATORY COMMISSION t
WASHINGTON, D.C. 20066 0001
'+9 * * * * *,o WISCONSIN ELECTRIC POWER COMPANY DOCKET NO. 50-266 POINT BEACH NUCLEAR PLANT. UNIT 1 h
AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.182 License No. DPR-24 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Wisconsin Electric Power Company (the licensee) dated January 21,1997, as supplemented on December 15,1997, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and I
security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
i 9803240308 980317 PDR ADOCK 05000266 P
l
- l. 2.
Accordingly, the license is amended by changes to the Technical Specifications as '
indicated in the attachment to this license amendment, and paragraph 3.B of Facility Operating License No. DPR-24 is hereby amended to read as follows:
B.
Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 182, are hereby incorporated in the license. The licensee shall operate the facility in accordance with Technical Specifications.
3.
This license amendment is effective immediately upon issuance. The Technical Specifications are to be implemented within 45 days from the date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION sh u-ra;l w n Linda L. Gundrum, Project Manager Project Directorate lil-1 Division of Reactor Projects - Ill/IV Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of issuance: March 17, 1998 i
i
(
@ LEty
~
UNITED STATES p
l g
j NUCLEAR REEULATORY C3MMISSION l
p f
WASHINGTON, D.C. 30856 4 001 i,
l WISCONSIN ELECTRIC POWER COMPANY l
DOCKET NO. 50-301 POINT BEACH NUCLEAR PLANT. UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.186 License No. DPR-27 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Wisconsin Electric Power Company (the licensee) dated January 21,1997, as supplemented on December 15,1997, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; l
B.
The facility will operate in conformity with the application, the provisions of the l
Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; l
D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
l
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 3.B of Facility Operating License No. DPR-27 is hereby amended to read as follows:
B.
Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.186, are hereby incorporated in the license. The licensee shall operate the facility in accordance with Technical Specifications.
3.
This license amendment is effective immediately upon issuance. The Technical Specifications are to be implemented within 45 days from the date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION S
dLuw Linda L. Gundrum, Project Manager Project Directorate lil-1 Division of Reactor Projects - Ill/IV Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of issuance: March 17, 1998 I
i
ATTACHMENT TO LICENSE AMENDMENT NOS.182 AND 186 TO FACILITY OPERATING LICENSE NOS. DPR-24 AND DPR-27 DOCKET NOS. 50-266 AND 50-301 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the enclosed pages. The revised pages are identified by amendment number and contain vertical lines indicating the area of change.
REMOVE INSERT 15.0.11-1 15.6.11-1 15.6.11-2 15.6.11-2 15.6.11-3
i 15.6.11 RADIATION PROTECTION PROGRAM Specific.ation Radiological control procedures shall be written and made available to all station personnel, and shall state permissible radiation exposure levels. The radiation protection program shall meet the requirements of 10 CFR 20.
Paraaraoh 20.1601 - Control of Access to Hiah Radiation Areas As provided in paragraph 20.1601(c) of 10 CFR Part 20, the following controls shall be applied to high radiation areas in place of the controls required by paragraph 20.1601(a) and
(
(b) of 10 CFR Part 20:
]
High Radiation Areas with Dose Rates Not Exceeding 1.0 rem / hour at 30 Centimeters from the Radiation Source or from Any Surface Penetrated by the Radiation; a.
Each entryway to such an area shall be barricaded and conspicuously posted as a high radiation area. Such barricades may be opened as necessary to permit entry or exit of personnel or equipment.
b.
Access to, and activities in, each such area shall be controlled by means of Radiation Work Permit (RWP) or equivalent that includes specification of radiation dose rates in the immediate work area (s) and other appropriate radiation protection equipment and measures.
c.
Individuals qualified in radiation protection procedures (e.g., health physics technicians) and personnel continuously escorted by such individuals may be exempted from the requirement for an RWP or equivalent while performing their assigned duties provided that they are following plant radiation protection procedures for entry to, exit from, and work in such area.
d.
Each individual or group entering such an area shall possess:
1.
A radiation monitoring device that continuously displays radiation dose rates in the area; or 2.
A radiation monitoring device that continuously integrates the radiation i
dose rates in the area and alarms when the device's dose alarm setpoint is reached, with an appropriate alarm setpoint, or 3.
A radiation monitoring device that continuously transmits dose rate i
l and cumulative dose to a remote receiver monitored by radiation l
l protection personnel responsible for controlling personnel radiation exposure within the area, or 15.6.11-1 Unit 1 - Amendment No. 60,68,182 Unit 2 - Amendment No. 66,78,186 l
.o 4.
A self-reading dosimeter (e.g., pocket ionization chamber or electronic dosimeter) and, (i)
Be under the surveillance, as specified in the RWP or equivalent, while in the area, of an individual qualified in radiation protection procedures, equipped with a radiation monitoring device that continuously displays radiation dose rates in the area; who is responsible for controlling personnel exposure within the area, or (ii)
Be under the surveillance as specified in the RWP or equivalent, while in the area, by means of closed circuit television, of personnel qualified in radiation protection procedures, responsible for controlling personnel radiation exposure in the area, and with the means to communicate with and control every individual in the area.
e.
Except for individuals qualified in radiation protection procedures, entry into such areas shall be made only after dose rates in the area have besa determined and entry personnel are knowledgeable of them.
High Radiation Areas with Dose Rates Greater than 1.0 rem / hour at 30 Centimeters from the Radiation Source or from Any Surface Penetrated by the Radiation, but Less than 500 rads / hour at 1 Meter from the Radiation Source or from Any Surface Penetrated by the Radiation:
a.
Each entryway to such an area shall be conspicuously posted as a high radiation area and shall be provided with a locked door or gate that prevents unauthorized entry, and, in addition:
1.
All such door and gate keys shall be maintained under the administrative control of the shift supervisor, radiation protection manager, or his or her designee.
2.
Doors and gates shall remain locked except during periods of personnel or equipment entry or exit.
b.
Access to, and activities in, each such area shall be controlled by means of l
an RWP or equivalent that includes specification of radiation dose rates in the
'~
immediate work area (s) and other appropriate radiation protection equipment and measures.
c.
Individuals qualified in radiation protection procedures may be exempted from the requirement for an RWP or equivalent while performing radiation surveys in such areas provided that they are following plant radiation protection i
procedures for entry to, exit from, and work in such areas.
I 15.6.11-2 4
Unit 1 - Amendment No. 60,68,182 l
Unit 2 - Amendment No. 66,78,186
1 t
d.
Each individual or group entering such an area shall possess:
1.
A radiation monitoring device the continuously integrates the radiation rates in the area and. alarms when the device's dose alarm setpoint is reached, with an appropriate alarm setpoint, or 2.
A radiation monitoring device that continuously transmits dose rate J
and cumulative dose information to a remote receiver monitored by radiation protection personnel responsible for controlling personnel radiation exposure within the area with the means to communicate with and control every individual in the area, or 3.
A self-reading dosimeter (e.g., pocket ionization chamber or electronic dosimeter) and, (i)
Be under the surveillance, as specified in the RWP or equivalent, while in the area, of an individual qualified in radiation protection procedures, equipped with a radiation monitoring device that continuously displays radiation dose rates in the area; who is responsible for controlling personnel exposure within the area, or (ii)
Be under the surveillance as specified in the RWP or equivalent, while in the area, by means of closed circuit television, of personnel qualified in radiation protection procedures, responsible for controlling personnel radiation exposure in the area, and with the means to communicate with and control every individual in the area, or 4.
In those cases where options (2) and (3), above, are impractical or determined to be inconsistent with the "As Low As is Reasonably Achievable" principle, a radiation monitoring device that continuously displays radiation dose rates in the area.
e.
Except for individual qualified in radiation protection procedures, entry into such areas shall be made only after dose rates in the area have been determined and entry personnel are knowledgeable of them.
f.
Such individual areas that are within a larger area that is controlled as a high radiation area, where no enclosure exists for the purpose of locking and where no enclosure can reasonably be constructed around the individual area need not be controlled by a locked door or gate, but shall be barricaded and conspicuous, clearly visible flashing light shall be activated at the area as a waming device.
15.6.11-3 L
Unit 1 - Amendment No. 182 Unit 2 - Amendment No. 186