ho RIVER BEND STATION ENVIRONMENTAL REPORT

]

OPERATING LICENSE O STAGE

\\

l SUPPLEMENT 3

ur"

/"f o

you.

l Acknowledgement of Receipt of Supplement to Environmental Report-73 Operating License Stage River Bend Station Please sign, date, and return this sheet to:

L.

L. Dietrich Lead Licensing Engineer Stone & Webster Engineering Corporation 3 Executive Campus P.O. Box 5200 Cherry Hill, N.J.

08034 2

Receipt of Supplement 3

to the Environmental Report -

j Operating License Stage is acknowledged.

My copy has been brought to current status and superseded pages have been removed and destroyed, as applicable.

Change my address as follows:

)

Please reassign this manual to:

l i

Signature Date Print name of person to whom ER-OLS is assigned Set number O

=_

1 J

a i

~ j 'i RBS ER-OLS T,

i j

s i

+

i SUPPLEMENT 3 INSERTION INSTRUCTIONS RIVER BEND STATION j

4 i

ENVIRONMENTAL REPORT - OPERATING LICENSE STAGE 1

sl 1

~

I j

The following instructions are for the insertion of Supplement 3 into the RBS ER-OLS.

Remove the pages, tables, and/or figures listed in the REMOVE column and replace them with the pages, tables, and/or figures 4

listed in the INSERT column.

Dashes (---) in either column indicate no action required.

f Vertical bars have been placed in the margins of inserted pages and tables to indicate revision locations.

t 1

i c

f l

1 L

I e

6 r

6 4

f l

+

l I

i i

-.,,, -.... - - - -...... ~.

n

4

\\

VOLUHF; 1 REMOVE

, INSERT t

s i

Table 1.3-1, Sheet 1 A

Table 1.3-1, Sheet 1

'iab, " QUESTIONS AND RESPONSES -

CHAPTER 1."

Insert immediately in front of page Q&R 1-i/-(1)

Page 2-1/ii Page 2-i/ii(2)

Page 2.2-19/20 Page 2.2-19/20 Page 2.3-1/la Page 2.3-1/la Page 2.3-5/5a Page 2.3-5/Sa(3)

Page 2.3-17/18 Page 2.3-17/17a Page 2.3-17b/18 w

\\_

II)This tab.sas inadvertently omitted from the Supplement 2 package.

(

Continues to be shown as Supplement 1/ Supplement 2.

Continus to be shown as Supplement 2/ Supplement 1.

1 l

1 l

1 l

l l

0 -

i

-., L.

j

}

VOLUME 2 4

i O REMOVE INSERT 1

i Page 2.5-15/16 Page 2.5-15/16 f~

Page 2.5-16a/16b Page 2.5-21/-

Page 2.5-21/-

Table 2.5-36 (2 sheets)

Table 2.5-36 (2 sheets)

Fig. 2.5-18 Fig. 2.5-18 i

i l

f i

f l

t 4

i a

i' I

I i

)

I I

l

!c i-i t

l@

i. j p

3 1

I 4

VOLUME 3 O

REMOVE INSERT Page Q&R 2-i/ii Page Q&R 2-i/ii Pages Q&R 2.2-1/2 Page Q&R 2.2-1/2 through Q&R 2.2-5/-

Page Q&R 2.3-21/-

Page Q&R 2.3-21/22 Page Q&R 2.3-23/24 Page Q&R 2B-3/4.

Insert immediately after page Q&R 2B-1/2.

Page 3-v/vi Page 3-v/vi Page 3-via/vib Page 3.4-3/4 Page 3.4-3/4 Page 3.4-4a/4b Page 3.4-4c/4d Fig. 3.4-3a Page Q&R 3-i/-

Page Q&R 3-i/-

Page Q&R 3.4-1/-

Pages Q&R 3.4-1/2 and Q&R 3.4-3/-

Page 4-i/ii Page 4-i/ii Page 4-iii/-

Page 4-iii/-

Page 4.2-1/2 Page 4.2-1/2 Page 4.2-2a/2b Page 4.2-3/4 Page 4.2-3/4 Page 4.2-4a/4b Page 4.2-4a/4b Table 4.2-1.

Insert immediately after page 4.2-7/.

Page Q&R 4-i/-

Page Q&R 4-i/-

Page Q&R 4.5-1/.

Insert immediately after page Q&R 4.3-1/.

O i

VOLUME 4 i

i I

a REMOVE INSERT 1

Page 5.5-3/4 Page 5.5-3/4 l

Table 5.8-7 Table 5.8-7(I) i

}

Page 6.2-3/4 Page 6.2-3/4(2) i l

l i

.l f

.I I

n ll i

1 I

i I

1 i

1 i

) Continues to be shown as Supplement 2.

)

Page 6.2-4 continues to be shown as Supplement 2.

}

4 i

l l

i l

}

i 1

l

+

l i

l l

\\

l i

)

RBS ER-OLS L

f ')

TABLE 1.3-1 v

SUBSTANTIVE INFORMATIONAL CHANGES FROM CONSTRUCTION PERMIT STAGE-i ER-OLS Section Change-Reason for Change

(

1.1 Operating date for Unit 1 Financial constraints rescheduled; Unit 2 present-and reduced load growth ly unscheduled.

projections 1.1 30 percent ownership of For CEPCO, to acquire Unit 1 by Cajun Electric needed capacity; for Power Cooperative (CEPCO)

GSU, to acquire the financing necessary for timely completion of River Bend Station 2.1 Additional site acreage Acquired property for acquired access from US Highway 61 2.2, Deletion of transmission a)The siting of and 3.7 line Routes D and E; need to interconnect

(

route designation with Big Cajun No. 2 changes; minor align-plant ment changes in Routes I,

II, III (formerly b) Design improvement B,

C, A, respectively) allowing combination l3 of.500-kV and 230-kV switchyards on origin-ally planned 230-kV site i

2.3, Hydrology study on Assess potential hydro-Appen-Alligator Bayou Crossing logical impact of sub-dix 2B stituting culverts for originally proposed i

bridge

(

2.3, Dewatering operation Temporary suspension of 4.2 performed over two construction during separate periods site preparation i

3.4 High-level platform type Improved safety, cost, n

intake structure design and technology to a low-level screened l

intake 1/'h Supplement 3 1 of 4 April 1982 x-[

r P

C :

i RBS ER-OLS 4

t I

CHAPTER 2 j

ENVIRONMENTAL DESCRIPTIONS TABLE OF CONTENTS I

Section Title Page

2.1 DESCRIPTION

OF THE STATION LOCATION 2.1-1 l

2.2 LAND 2.2-1 2.2.1 The Site and Vicinity 2.2-1 2.2.1.1

.The Site 2.2-1 f

2.2.1.2 The Vicinity 2.2-2 e

2.2.2 Transmission Corridors and offsite Areas 2.2-9 f

s I

2.2.2.1 Transmission Corridor Routes 2.2-9 2.2.2.2 Land Uses Within the Corridors 2.2-10 2.2 2.2.1 Land Use Along Route I 2.2-10

[

2.2.2.2.2 Land Use Along Route II 2.2-11 j

2.2.2.2.3 Land Use Along Route III 2.2-12 2.2.2.3 Land Use Significance 2.2-13 2.2.2.4 Offsite Areas 2.2-13

}

2.2.3 The Region 2.2-14 2.2.3.1 Land Uses 2.2-14 i

O 2.2.3.2 Settlement Patterns 2.2-14 2.2.3.3 Transportation Networks 2.2-17 j

l 2.2.3.4 Agriculture 2.2-17 l

2.2.3.5 Institutions and Public Lands.

2.2-18 1-r 2.3 WATER 2.3-1 e

2.3.1 Hydrology 2.3-1 i

2.3.1.1 Surface Water 2.3-1 2.3.1.2 Groundwater 2.3-7 2.3.1.2.1 Description of the Groundwater Flow System 2.3-7 2.3.1.2.2 Configuration of the Piezometric l

Aquifer' Characteristics 2.3-10a Surface in the Unconfined Aquifer 2.3-10 2.3.1.2.3 2.3.1.2.4 Surface Water / Groundwater 1

Interactions 2.3-11a 1

l-2.3.1.2.5 Historic Regional Decline.in-the Piezometric Surfaces of the Zone 3 i

Aquifer and the Upland Terrace Aquifer 2.3-13 2.3.2 Water Use 2.3-15 i

i i

Supplement 1 2-i.

October.1981 s!

5 i

i i'

[

I

~ _ --,_

i

RBS ER-OLS CHAPTER 2 TABLE OF CONTENTS (CONT)

Section Title Page l

2.3.2.1.2 Private and Municipal Wells Near the Plant Site Area 2.3-15 2.3.2.1.3 Drawdown Created by Pumping Wells at the Plant 2.3-16 2.3.2.1.4 Drawdown in the Upland Terrace Aquifer Due to Construction Dewatering 2.3-18 2.3.2.2 Surface Water Use 2.3-21 2.3.2.2.1 Public Supply 2.3-21 2.3.2.2.2 Industrial Supply 2.3-21 2.3.2.2.3 Irrigation 2.3-22 2.3.2.2.4 Water-Based Transportation 2.3-22 2.3.2.2.5 Water Use Restrictions 2.3-24 2.3.2.2.6 Lentic Waters 2.3-25 2.3.2.2.7 Recreational Water Use 2.3-25 2.3.2.2.8 Sport and Commercial Fisheries 2.3-26 2.3.3 Water Quality 2.3-27 2.3.3.1 Surface Water 2.3-27 2.3.3.1.1 Mississippi River 2.3-27 2.3.3.1.2 Local Drainage Courses 2.3-31 2.3.3.1.3 Existing Surface Water 2

l Quality Stresses 2.3-32 2.3.3.2 Groundwater Quality 2.3-32 2.4 ECOLOGY 2.4-1 2.4.1 Terrestrial Ecology 2.4-1 2.4.1.1 The Site and Vicinity 2.4-1 2.4.1.1.1 General Site Characteristics 2.4-1 2.4.1.1.2 Flora of the Site 2.4-2 2.4.1.1.3 Terrestrial Fauna of the Site 2.4-5 2.4.1.1.3.1 Mammals 2.4-5 2.4.1.1.3.2 Birds 2.4-7 2.4.1.1.3.3 Reptiles and Amphibians 2.4-13 2.4.1.1.4 Threatened or Endangered Species 2.4-17 2.4.1.1.5 Environmental Stress 2.4-17 2.4.1.1.6 Special Use Areas 2.4-19 2.4.1.1.7 Summary of Ecosystem Dynamics 2.4-20 2.4.1.2 Transmission Corridors and Offsite Areas 2.4-21 2.4.1.2.1 Flora of the Transmission Corridors 2.4-22 2.4.1.2.2 Fauna of the Transmission Corridors 2.4-25 2.4.2 Aquatic Ecology 2.4-27 2.4.2.1 Site and Vicinity 2.4-27 Supplement 2 2-ii March 1982

RBS ER-CES

/~'

and vocational-technical schools throughout the state (27).

(,S/

Those schools within 80 km of River Bend Staticn are listed in Table 2.2-17.

State correctional institutions within 80 km of River Bend Staticn are given in Table 2.2-10.

Major public lands intended for recreation or preservation are identified in Tables 2.2-19 and 2.2-20 and Fig. 2.2-8.

Within the 80-km

radius, Homochitto National Forest in Mississippi includes portions of all four counties.

Within the National

Forest, there are two game preserves and a

recreational site for swimming, fishing, and camping.

The Louisiana State Parks dystem includes state parks, commemorative

areas, preservation
areas, and experiment stations (33).

Those within the 80-km radius are identified in Table 2.2-19.

Wildlife areas in which hunting and fishing are permitted are identified in Table 2.2-20(3*,3s).

There are no wildlife refuges within 80 km of River Bend Station.

O 2.2-19 a

RBS ER-OLS References - 2.2 1.

Telephone conversation between J.K.

Jackson and C.S.

Ellis of Stone & Webster Engineering Corporation,

Boston, MA, and J.

Perry, Agent for Woodville District, Illinois Central Gulf Railroad, Slaughter, LA, December 18, 1979.

2.

Telephone conversation between C.S.

Ellis of Stone &

Webster Engineering Corporation,

Boston, MA, and B.

Phipps and J.

Butler of American Telephone Telegraph Long Lines Division, December 21, 1979.

3.

Supplemental Environmental Information Document, River Bend Nuclear Power Station.

Prepared for Cajun Electric Power Cooperative, Inc. by Bovay Engineers, Inc., Baton 3

Rouge, LA, February 1980.

4.

Louisiana Population Estimates by District and Parish, j

Table III, Louisiana Technical University, Division of Business Research, Ruston, LA, February 1979.

5.

Telephone conversation between C.S.

Ellis of Stone &

Webster Engineering Corporation,

Boston, MA, and N. Wagoner, Louisiana Department of Transportation and Development, Baton Rouge, LA, December 26, 1979.

5.

Telephone conversation between C.S.

Ellis of Stone &

Webster Engineering Corporation,

Boston, MA, and Attorney S.P.
Dart, an owner of the former Dipple and Enette Field, St. Francisville, LA, January 22, 1980.

7.

Telephone conversation between C.S.

Ellis of Stone &

Webster Engineering Corporation,

Boston, MA, and C.
Taylor, Maintenance Section, Louisiana Department of Transportation and Development, Baton
Rouge, LA, January 22, 1980.

8.

Telephone conversation between C.S.

Ellis of Stone &

Webster Engineering Corporation, Boston, MA, and

Staff, Redi-Mix
Concrete, St.

Francisville, LA, December 20, 1979.

9.

Telephone conversation between C.S.

Ellis of Stone &

Webster Engineering Corporation,

Boston, MA, and F. Metz, Joan of Arc Co.,

St. Francisville, LA, Decer.cer 20, 1979.

10. Telephone conversation between C.S.

Ellis of Stone

& Webster Engineering Corporation,

Boston, MA, and Supplement 3 2.2-20 April 1982

RBS ER-OLS 2.3 WATER r~x i

)

\\_ /

2.3.1 Hydrology 2.3.1.1 Surface Water River Bend Station is located above the Mississippi River floodplain on

clevated, gently sloping terrain at approximately River Mile 262.

The plant is separated from the river by a natural levee formed above the river bank and by the lower floodplain area which is crossed by Alligator Bayou and its tributaries.

The river locati~on of the station site is midway between Bayou Sara Bend and False River cutoff on a 6-mi reach of straight river channel alignment.

At the station site the channel width is approximately 1,700 ft, but it increases in width downstream to more than 4,000 ft within 4 mi.

Current velocities were examined as part of a hydrographic survey conducted in 1972 (Appendix 2A).

The highest current velocities are on the eastern side of the river where the channel deepens along the bank bounding the site.

A river cross section showing channel current velocities and directions is presented in Appendix 2A, Exhibit 19.

Channel current velocities are similar to those measured at Tarbert g

Landing, Mississippi, about 44 river miles upstream of the

{s )

site.

Main channel velocities during the period 1966-1970 at that location had a range of 3.0 to 9.5 fps.

During the site hydrographic study, the river stage was approximately 8 ft above average annual stage, and velocities varied from slack bank currents to 8.3 fps in the main channel.

The high energy, turbulent character of

~ he flow exerts an t

erosive force on the river channel and bank.

Based on observations by the Army Corps of Engineers, the long-term average bank erosion rate along this portion of the river is about 8 ft per yearct)

As discussed in Section 4.6.2, the U.S.

Army Corps of Engineers will install concrete revetment on the Mississippi River Channel in the site vicinity.

Work is presently scheduled to begin in the fall of 1984.

The design of the 3

cooling tower makeup water intake structure is discussed in Section 3.4.2.1.

Fig. 3.4-4 shows that the intake structure 1

is protected against river-induced erosion by covering the embayment slopes with 2-ft-thick

riprap, which is placed over a 1 1/2-ft-thick gravel base.

Together these measures ensure a continuous plant water supply.

Supplement 3 2.3-1 April 1982

(j).

L C

RBS ER-OLS A cross section showing the topography between the river and z

the plant is presented in Fig.

2.3-1.

A topographic map of the site is provided in Fig. 4.3-1.

A bathymetric survey map showing the river channel contours near the embayment area is presented in Fig.

2.3-2.

The Mississippi River at Bayou Sara (River Mile 265.4) has a drainage area of 1,129,400 sq mi.

Of this

area, about 1 percent (13,000 sq mi) is in Canada, and the rest is located mainly in the central United States.

Tributaries to the river extend into the state of New York in the East and into Wyoming and Montana in the West.

The drainage area is O

Supplement 1 2.3-la October 1981 0

RBS ER-OLS valley with relatively steep slopes.

The channel and valley f3

(

)

become broader in the downstream direction.

Within the Mississippi River floodplain, the bayou flows in a shallow 2

trough between the Mississippi River natural levee and the escarpment bounding the valley.

In that region, the stream flows through a small, standing water body known locally as Needle Lake.

The lake is about 1,700 ft long and 40 ft in average width (about 1.5 acres).

Water depth is normally about 3

ft.

A rise in water level due to local storms floods the surrounding sump area.

Alligator Bayou is subject to short periods of high runoff or storm floods, and extended drought periods of zero flow.

The U.S.

Geological Survey has maintained a crest stage gauge on Alexander Creek from 1953 to the present (noncontinuous).

The drainage area at this point in the creek is 23.9 sq mi.

The estimated flood flow distribution for Alligator Bayou, based on Alexander Creek data, is shown in Fig. 2.3-11.

This figure also shows the estimated flood flows for the West Fork Thompson Creek flow gauge (1950-1970).

During flood flows Alligator Bayou carries an increased sediment load and provides an appreciable amount of sediment deposition within the floodplain area.

Most sedimentation occurs as Alexander Creek leaves the hills and enters the alluvial valley.

Channel length from the headwater to the southern GSU property line is about 18 mi.

(}

A profile of the channel bed is shown in Fig. 2.3-10.

(./

River Access

Road, extending from the plant to the Mississippi River, has been constructed across Alligator Bayou for the purpose of providing access to the intake structure and barge slip area and as a.means of conveyance of heavy construction loads.

This road will remain after plant construction is completed.

Culverts have been placed in this roadway to allow passage of flow through Alligator Bayou to Thompson Creek and the Mississippi River.

Appendix 2B ' presents a

study of the effects of River Access Road construction on Alligator Bayou hydrology.

Section 4.6.2 1

details the effects of plant features on erosion, explaining the various erosion control measures which have been undertaken.

Several small farm ponds are located in the site vicinity.

Locations of these ponds and approximate sizes are presented in Section 4.2.

Local drainage courses subjected to extremely severe assumed meteorological and geological conditions could cause limited flooding at the site.

The design flooding condition is the unlikely event of one-half-the Probable Maximum Flood on Supplement 2 2.3-5 March 1982

%.J i

,,e-+y

,r_m

RBS ER-OLS West Creek and Grants Baycu in combination with the Operational Basis Earthquake and severe winds which could cause flooding to 95.1 ft msl at West Creek.

The plant area 1

i l

i O

Supplement 1 2.3-Sa October 1981 0

RBS ER-OLS (Oj 30,

365, 3,650 and 14,600 days.

A discussion of the input parameters and assumptions used in this analysis is presented in Section 2.4.13.2.5 of the FSAR.

-Fig. 2.3-22 shows that after. 40 yr (14,600 days) of continuous pumping, drawdown of the Zone 3

piezometric surface is predicted to be less that 4 m (13 ft) at a distance of 30 m (100 ft) from the wells and is predicted to be less than 2 m (7 ft) at a distance of 3,050 m (10,000 ft) from the wells.

As a result, a localized cone of depression will form around the wells in the piezometric surface of the Zone 3 Aquifer and will cause a localized reversal of the hydraulic gradient.

It is predicted that pumping the two Zone 3 wells at 6.3 1/s (100 gpm) each for 40 yr will cause approximately 1.8 m (6 ft) of hydraulic-head decline in the St. Francisville 4

water supply wells that are located approximately 4.9 km (16,000 ft) from the plant area (Fig. 2.3-21).

This is equivalent to an annual rate of decline of 0.046 m/yr (0.15 ft/yr).

This is an insignificant amount compared to the regional decline in hydraulic head of 0.9 to 1.2 m/yr (3.0 to 3.9 ft/yr) in the Zone 3 Aquifer due Lo pumpage in 3

Baton Rouge (Section 2.3.1.2).

The three water supply wells operated by the town of St. Francisville are the nearest

/'N wells to the plant in the Zone 3 Aquifer.

The rate of (s-)

hydraulic head decline in the Zone 3 Aquifer at the site from pumpage in St. Francisville is estimated to be small.

Thus the cumulative rate of hydraulic head decline is expected to be on the order of 1.25 m/yr (4.05 ft/yr),

and the majority of this decline is attributed to groundwater withdrawals in the Baton Rouge area.

Ground subsidence at the site due to hydraulic head decline from Baton Rouge groundwater withdrawals is discussed in 3

FSAR Section 2.5.4.1.1.

Evaluations have indicated no measurable subsidence at the site to date; however, a

very conservative projection of possible subsidence at the site for the next 40 yr indicates a value of 0.03 m (0.11 ft).

Assuming a

composite saturated aquifer thickness of 250 m (820 ft), a porosity of 12 percent, and that all aquifer compaction results in porosity decrease, a subsidence of 0.03 m corresponds to a porosity decrease of 0.113 percent.

This porosity loss is not expected to have a noticeable effect on aquifer permeability.

The third well at the plant, labeled No. 72 on Fig. 2.3-20, was emplaced in the Upland Terrace Aquifer to a

depth of 46 m (150 ft).

This well is equipped with a 50-1/s (800-c Supplement 3 2.3-17 April 1982 V

RBS ER-OLS gpm) pump and was installed to provide water for fire protection.

Drawdown of the piezometric surface in the Upland Terrace Aquifer due to pumping this well at 50 1/s (800 gpm) for 12.5 hr, which is the time required to fill the fire I

protection storage

tanks, was analyzed.

Fig. 2.3-22 q

displays the predicted values of drawdown versus distance from the well after 12.5 hr of continuous pumping at 50 1/s (800 gpm).

This figure shows that drawdown at a distance of 305 m (1,000 ft) is predicted to be less than 6 cm (0.2 ft).

It also shows that, beyond a distance of 400 m (1,300 ft) from the well, no drawdown is predicted to occur.

As a

result, a very localized cone of depression will form around this well and will locally reverse the hydraulic gradient in the immediate vicinity of the plant.

The cone of depression is predicted to extend a maximum of 335 m (1,100 ft) from the well after 12.5 hr of pumping.

Therefore, drawdown in the Upland Terrace hquifer due to pumping this well will be contained entirely on the site property.

A discussion of Supplement 3 2.3-17a April 1982

a

.-4-r 2.

.S.

2

+- - ~-

m a

...*.-.6-e 4.s 1

1 RBS FSAR t

f I

m i

I a

i t

I,

!i THIS PAGE INTENTIONALLY BLANK l

L i

i c

s J

4 t

I i

i I

i l

l

)

Supplement-3 2.3-17b April 1982 l

1 I

l I

f l

l l

1 l

t -..

RBS ER-OLS the input parameters and assumptions used in this analysis is presented in FSAR Section 2.4.13.2.5.

2.3.2.1.4 Drawdown in the Upland Terrace Aquifer Due to Cor.struction Dewatering During construction dewatering, which took place from May 1976 to May 1977 and from May 1979 to the time in 1981 when it was no longer required, the piezametric surface in the Upland Terrace Aquifer was lowered so that construction could occur.

The dewatering system was designed and operated by Wellpoint Dewatering Corporation, New York, NY, in accordance with engineer-specified requirements.

The dewatering system consisted of 44 30-cm (12-in) diameter wells that were emplaced to el -35 to -45 ft into the top of the clay layer immediately below the deepest large sand layer in the Upland Terrace Aquifer.

The wells were drilled in a

rectangular pattern around the periphery of the excavation.

Each well was equipped with a 44-1/s (700 gpm) vertical turbine pump.

Inside the rectangular

area, a

series of 30-cm (12-in) diameter sand drains was used to transmit perched water down to the Upland Terrace Aquifer.

Additional descriptive informaticn regarding the excavation and the dewatering system is provided in FSAF Section 2.5.4.5.

The average discharge rate of the dewatering system during the first phase of dewatering, frcm May 1976 to May

1977, was approximately 490 1/s (7,700 gpm).

The maximum discharge rate was approximately 1,370 1/s (21,700 gpm).

Fig. 2.3-23 shows the weekly discharge rate of the dewatering system.

Initially it was necessary to operate the system at a

high discherge rate in order to get the piezometric surface drawn down to a sufficiently low level to allow construction to proceed.

After, this initial period, during which the Upland Terrace Aquifer was being dewatered, it was not necessary to operate the system at as high a discharge rate.

After August

1976, the discharge rate was decreased as the groundwater flow system approached steady-state conditions in response to the pumping stress (Fig. 2.3-23.)

The hydrcgraphs of piezometers and observation wells in the Upland Terrace Aquifer in Fig. 2.3-24 show the response of the aquifer to the operation of the dewatering system.

i Maximum drawdown of the piezametric surface of the Upland Terrace Aquifer occurred in March 1977.

After this time, water levels began to rise and eventually attained i

l 2.3-18 i

RBS ER-CES Grace Episcopal Church, Louisiana's second oldest Protestant church, was built in 1827 in St.

Francisville, Acts of

[)

Incorporation and Investiture followed in 1829.

Shelled

\\_/

during the Civil Kar, the church began a rebuilding program with final restoration in the 1880s.

The church is located in the center of St.

Francisville, approximately 5.7 km (3.5 mi) west-northwest of the site.

Both Propinquity and Grace Episcopal Church in St. Francisville are within the historic district that was nominated for inclusion in the National Register of Historic Places in the Spring of 1979.

The area covers more than four blocks.

Bounded by Royal and Ferdinand Streets, the district includes private homes, a court house, law offices, a

bank, and town hall.

The West Feliciana Historical Society is attempting to extend these boundaries in order to further preserve St. Francisv111e history (33).

The

Cottage, a

series of buildings erected from 1795 to 1859, was originally the hcme of "The Fighting Butler Family."

Andrew Jackson is known to have stopped there after the Battle cf New Orleans.

The Cottage contains much of the original furniture, and 15 plantaticn outbuildings are still standing.

It is situated on US Highway 61, approximately 11.2 km (7.0 mi) ncrth-northwest of the site.

Overnight accommodations are available in the home.

O 70sedown Plantation, listed by the state of Louisiana as a place of historic interest, is located about 5.8 km (3. 6 mi) northwest of the site on State Highway 10.

Rosedcwn Plantation -was a

Spanish grant made in 1789.

Daniel Turnbull built the present Rcsedown in 1835.

The house and the 17th century style gardens at Rosedown are completely restored and stand as a museum of the Old Scuth.

2.5.3.2 Archaeolcgical Significance An archaeological investigation was performed through archival research and foot investigation in December 1971 and was updated on October 9,

1972.

From these investigations it was learned that Indians traversed the area but no archaeological remains were found that were indicative cf long-term village cccupation(3*).

Sites 4 and 5

on Fig. 2.5-18 locate the areas where historic campsite artifacts were found.

Additional information is found in Section 2.5.3.4.

()

2.5-15 n

m-

RBS ER-OLS 2.5.3.3 Natural Landmarks There are no natural landmarks within 16 km (10 mi) of the site listed in the National Register of Natural Landmarks through December 1979.

2.5.3.4 Historic and Archaeological Significance Along Transmission Rights-of-Way The only National Register of Historic Places property within 2 km (1.2 mi) of any of the three transmission corridors is the Port Hudson Battlefield, which is 11.8 km (7.4 mi) south-southwest of River Bend, crossed by Route II.

Section 2.2.2 describes the corridor.

The archaeological significance of this area is discussed in the following paragraphs.

Route II passes within 2 km (1.2 mi) of the Baker Heritage Museum, a site of historic interest recognized by the state of Louisiana and local communities.

The museum is on Mississippi and Adams Streets in Baker, Louisiana, one block east of State Road 19.

The museum includes a general store and rural life exhibits housed in a

turn-of-the-century home cas-37) 3 Eighteen archaeological and historical sites, five of which pertain to the Port Hudson Battlefield

area, are located within 2 km (1.2 mi) of the transmission corridors.

These sites were locr.ted through use of archaeological files and

maps, and subsequent foot investigations and construction surveys by state archaeologists.

The locations attest to the presence of peoples during prehistoric and historic eras and include mounds, campsites, forts,

villages, and house sites.

Table 2.5-36 and Fig. 2.5-18 locate and identify the archaeological and historical sites within 2 km (1.2 mi) of the transmission corridors.

Prior to construction, an archaeological investigation of the River Bend site was performed by Robert W.

Neuman, a

professional archaeologist from Louisiana State University.

His investigation uncovered three campsite areas around Site 5

on Fig. 2.5-18.

However, the artifacts did not indicate long-term village occupation or mound sites.

Several other sites are located partially or totally within the transmission corridors <as>

Among these are the Riddle a

Cemetery at Site 6

(Spot Find No. 1) and the Civil War breastworks at Sites 8, 9,

and 18.

Sites identified as 8

through 11 and 18 are located within the Port Hudson Battlefield site.

Supplement 3 2.5-16 April 1982

..... ~. _ _... _ _ _ _ -. - _. _ _.... _ _. _. _..... _....

. - - _ _ _. =. _ - _ _ _ _ _

r.

i

}

RBS ER-OLS l-L' Prior to the-construction of the original-transmission lines-.

I-near the Port Hudson Battlefield area,.the GSU right-of-way l

. department established the transmission line route in a

e i

2 1

4 4

(:

i i

l i

l y

r

_q i

1 i

i l

t 1

I i

i r

t i

f I

i l

l r

I 1

I

-l 1

t

.I L

i

[:

l i

1 1

i

-Supplement 3

.2.5-16a April 1982 1

4.

I o

i i

1 l

i i

)

.I l

RBS ER-OLS O

i THIS PAGE INTENTIONALLY BLANK l

O l

l Supplement 3 2.5-16b April 1982 l

l i

I RBS ER-OLS

~ ("'S(

33. Telephone conversation between Elizabeth Dart, President

(_,/

of-the West Feliciana Historical

Society, St.

Francisville, LA, and Loretta Garcia, Stone & Webster Engineering Corporation, Boston, MA, January 21,

1980, 1 pm.
34. Neuman, Robert W.

An Archaeological Survey of the River Bend Station, West Feliciana Parish, LA, December 1971.

Addendum, October 9,

1972.

(For Gulf States Utilities Company, Beaumont, TX)

35. Louisiana Office. of Tourism.

A Traveler's Guide to Louisiana, pamphlet.

36. Louisiana Office of Tourism.

Louisiana, What a Way to Get Away, 8th ed.,

tour guide.

37. Capital Economic Development District.

Have a Capital Time in the Capital District, pamphlet, Fall 1974.

38. Neuman, Robert W.

Cultural Resource Survey of the Gulf States Utilities Transmission Line Right-of-Ways, Louisiana, August 1978.

(For Gulf States Utilities Company, Beaumont, TX)

39. Neuman, Robert W.

An Archaeological and Historical Site 3

O Survey of River Bend Station Transmission Line B

[ Route I].

June 1978.

(For Gulf States Utilities Company, Beaumont, TX) i 4

t

O

.x Ov v

RBS ER-OLS TABLE 2.5-36 ARCHAE 01DGICAL AND HISTORICAL SITES WITHIN THE RIVER BEND STATION TRANSMISSION SYSTEM Map Ref.

Survey No.(13 No.(as Site Name

. Location De scri ption.

1 16IV7 Mays Place Camp Approx 1.5 km east of Plain sherds found in s

Webre Station earthen mound 2

16XEF3 Spot Find No. 2 Approx 8.7 km east of Prehistoric campsite; ceramic l:

River Bend, under Route III fragments found 3

16XEF2 Spot Find No. 1 Approx 5.4 km east of Gravel flakes and chips l8 River Bend on Route III on mound site 4

16WF19a Combined switchyards Small concentration of area, onsite sherds (ceramic pots) 5 16WF19b-d Onsite along old Three campsite spoil tram line, just north piles with many sherds of Route I.

6 16WF31 Riddle Cemetery SE of Point J, Cemetery with gravestones adjacent to Route II and unmarked graves l:

7 16WF4 Riddle Mounds Approx 1.5 km east of

'Iwo mounds with site Point J collection done 8

16EF18 Port Hudson No. 2 Approx 300 m south of Civil War breastwork about (Commissary Hill)

Sandy Creek on Route II 1 m high and 40 m long ls 9

16EF19 Port Hudson No. 3 Approx 1.5 km northwest Three Civil War breastworks s

of Point L on Route II 3 to 4 m in height 10 16EF7 Port Hudson Campsite West of Foster Creek Scattered Civil War debris 1GXEF1 and Artillery Ridge, and east of Sandy sites etc Creek, within 2 km NE of Route II 11 16EBR47 Approx 300 m west of Civil war breastwork, Route II and 700 m south 15 m long and 2 m high of Point L

.12 16PC31 Waterloo Just north of False River Historic Town and associates channel and Mississippi landing area, foundations River confluence, within and chimneys visible 2 km of Route I 1 of 2 April 19 82 Supplement 3

L l

'w x

RBS ER-OLS TABLE 2.5-36 (Cont)

Map Ref.

Survey No.(83 No. (a3-Site Name Location Description 13 16WBR3 Smithfield No. 3

,About 1.2 km SW of Mound, 12 m in diameter Point E, along Route I 14 16WBR2 Pitcher Place West of Route I, about Indian mounds in hectare (No. 1 and 2) about 3 km south of site Smithfield No. 3, near Bucche 15 161V2 Peter Hill East side of Bayou W o mounds in plowed Grosse Tete, approx field with pottery 0.6 km north of Route I, finds near Point G 16 16IV18 1.6 km north of Point G, Plain body sherds Route I, on north side collected in plowed of Bayou Grosse Tete field 17 16IV16 South of Rosedale 163 km north of Plain sherds found Plantation Point G near west in low earth mound bank of Bayou Grosse s

Tete, Route I 18 16EBRS2 Approx 400 m south of Civil War breastwork, 2 m Point L on Route II high and 6-8 m wide at base (a3 Map reference numbers refer to Fig. 2.5-18.

(r 3 Survey numbers represent Louisiana State and Louisiana State University site reference numbers.

The "16" stands for Inuisiana and the letters correspond to the parish of the find.

Sources: Neuman, R. W. Cultural Resource Survey of the Gulf States Utilities Transmission Line Right-of-Ways, Iouisiana, August 1978.

Neuman, R. W. An Archaeological Survey of the River Bend Station, West Feliciana Parish, Louisiana, December 1971, with Addendum, October 1972.

4 Consolidated Site Records, Inuisiana Archaeological Survey, archives of the Louisiana Office of Historic and Archaeological Preservation.

f:

Archaeological Site Data, Coastal Environments, Inc., Baton Rouge, LA, archives l:

of the Louisiana Office of Historic and Archaeological Preservation.

Neuman, R. W. An Archaeological and Historical Site Survey of River Bend Station Transmission Line B (Route I].

June 1978.

2 of 2 April 19 82 Supplement 3

e@

f'(q b

N o

b

\\

\\

/$hikhHARD END

/i

\\

gj g

(

s

/k2

/

7 j

wc,,

s w, sy-P., s

=L L w

au

-r-m.z r

s

~

m pgg ) m,

~

x f

e s@

\\

,i f,7

~

e

(

m s

\\

/

43 sq y

+

g "g

sx m,g, 3

s x

m y

x.

ww

\\

7 g

\\

\\

\\

'q$;'5 N

\\

g'

' x Jt t

/lQ T

\\

<@N

'G.4 c

'q $ b,on A

/

s N

/

t' f

/' (N s

s ss e 1;

l x.

h j

I

\\

/

l

'\\ /

[

\\

)

\\+

(

7 w

N

\\\\

f

'(

\\

l bfp l

N, b

c 6

H f-c

)

{

/

l O

/)

\\

S' LEGEND:

./

]

Mc KNIGHT TRANSMISSION LINE ROUTES SWITCHING STATION ROUTEI d

/

ROUTE 11

/

/

I ROUTE Ill j

CA DESIGNATED LINE cr SEGMENT POINTS f

)

{'

st 7,

(

)

f

/

'I h

NOTE wi' THE NUMBERS REFER TO ARCHEOLOGICAL SITES IN y

r TABLE 2.5-36

)k

)

(

>_)

{

6?

,-(

p

~

6 m

j O

5 i

i g

SCALE-MILES

[

O, 5,

10, x,

'E

]

SCALE-KILOMETERS m

'N i~

FIGURE 2.5-18 y

'w A l

< i'.

'D e.

ARCHAEOLOGICAL AND HISTORICAL 2M SITES ALONG THE Y217,., ;,

T TRANSMISSION CORRIDORS x

/

s0 gg A

}\\*\\"*

\\{

IVER BEND STATION c

\\

ENVIRONMENTAL REPORT-OLS 7

SUPPLEMENT 3 APRll 1982

.~

t RBS ER-OLS O

CHAPTER 1 QUESTIONS AND RESPONSES TABLE OF CONTENTS NRC Supplement Q&R Question No.

No.

Page No.

E470.1 2

2.1-1 E310.7 2

2.1-2

[

E470.2 2

2.2-1 E290.6 2

2.2-2 l

E240.1 1

2.3-1 E240.2 1

2.3-2 r

E240.3 1

2.3-3 E240.4 1

2.3-6 E240.5 2

2.3-7 I

l E240.6 1

2.3-8 i

E240.7 1

2.3-9 E240.8 1

2.3-10 I

h E240.9 2

2.3-11

\\s)

E240.10 1

2.3-12

[

E240.11 1

2.3-13 r

E240.12 1

2.3-14 E240.13 1

2.3-15 I

E240.14 2

2.3-16 i

E291.1 2

2.3-17 i

j E291.2 2

2.3-18 E291.3 2

2.3-19 i

E291.4 2

2.3-20 E291.12 2

2.3-21 E240.27 3

2.3-22 i

E240.28 3

2.3-23 E240.34 3

2.3-24 j

E291.13 2

2.4-11 E310.9 2

2.5-1 1

E310.10 2

2.5-2 j

s E451.1 1

2.7-1 E451.2 1

2.7-2 l

E451.3 2

2.7-3 I

Supplement 3 Q&R 2-1 April.1982 O-2 f

a l

I.,,

.__,--,,,,,..,,,-._..,.,-_-.,__....,m..~..

~

RBS ER-OLS CHAPTER 2 QUESTIONS AND RESPONSES TABLE OF CONTENTS NRC Supplement Q&R Question No.

No.

Page No.

E290.1 2

2.9-1 E290.2 2

2.9-2 E290.3 2

2.9-3 E290.4 2

2.9-4 E240.15 1

2B-1 E240.32 3

2B-3 E240.33 3

2B-4 O

Supplement 3 QSP. 2-ii April 1982

I RBS ER-OLS QUESTION.E470.2 (2.2) l

(

r Provide definitive data on agricultural productivity for 160 i

annular sectors to 50 miles (e.g.,

edible crops,

meat, and l

milk).

General production information by parish is not adequate.

l

RESPONSE

Tables 2.2-12a, 2.2-12b, and 2.2-15a show agricultural l2 production by annular sector to a distance of 80 km.

Since the Environmental Report was prepared using metric measurements,~these tables were prepared to conform

and, therefore, only show 144 annular sectors instead of 160 which result when annular sectors are designated in miles.

i s

k i

Supplement 2 Q&R 2.2-1 March 1982 i

i i

RBS ER-OLS QUESTION E290.6 (2.2)

References (p.2.2-20).

Please provide the staff with a copy of Reference 3,

" Supplemental Environmental Information Document," October 1979.

RESPONSE

Copies of this document are provided under separate cover.

l I

l 1

l Supplement 2 Q&R 2.2-2 March 1982 0

t RBS ER-OLS QULSTION E291.12 (2.3.3)

Provide complete reference citing of the Draft Environmental l

Impact Statement for Big Cajun No. 2 - Unit 3.

I

- RESPONSE Copies of the Final Environmental Impact Statement for Big Cajun No. 2 - Unit 3 are provided under separate cover.

1 I

4 1

I i

i I

i t

i 2

i i'

l l

Supplement 2 Q&R 2.3-21 March 1982

-ww-w--

r.,-m.,ww--.-,,,,-=,-----ermm--------

+

,----..ee------.r

- -,c-w,,, - - -,.---,e m

y-,,,w--

ym-,w,--&.--i.----,e,

RBS ER-OLS

.. QUESTION E240.27 (2.3.3.1)

There appears to be a potential for loss of make up water and interruption of normal power generation due to sediment induced cavitation in the intake pumps.

In the ER section 2.3.3.1.1 it is stated that suspended sediment concentrations at Red River Landing and Baton Pouge range from about 10 to 2,500 mg/1.

In the FSAR Section 2.4.11.5 it is stated that by the time influent turbidity consistently exceeds the ambient turbidity

level, sediment deposition within the recession would have begun to affect intake operation.

Discuss operational procedures and the method to be used in determining turbidity.

In light of the significant range of observed suspended sediment concentrations in the Mississippi River, discuss how ambient turbidity is determined.

Also, what are the maximum sediment concentrations at which the intake pumps can operate without incurring cavitation.

Finally, discuss the likelihood of sediment induced cavitation outages.

RESPONSE

The response to this request is provided in revised Section 3.4.1.2.

O i

l l

Supplement 3 Q&R 2.3-22 April 1982

RBS ER-OLS

(#'N t

)

-QUESTION E240.28 (2.3.1.1)

The _ Mississippi River-bathymetric survey results shown in Figure 2.3-2 show a channel upstream of the intake structure with depths up to

-70 feet MSL.

With reference to this figure, locate and describe in detail the sandbar growth discussed in FSAR Section 2.4.11.5 with respect to operability of the intake and discharge facilities.

RESPONSE

^

FSAR Section 2.4.11.5 refers to sandbar growth and sedimentation in the River Bend Station embayment, not the Mississippi River main channel.

Fig. 2.3-2 is not of sufficient detail to present embayment sedimentation characteristics.

The predicted sedimentation characteristics of the embayment are presented in FSAR Appendix 2E, and its potential impact on intake and discharge capability is discussed in revised Section 3.4.1.2.

O 4

+

)

Supplement 3 Q&R 2.3-23 April 1982

'8

--n-

-m---

RBS ER-OLS QUESTION E240.34 (2.3.2.1) lh In your discussion of drawdown due to groundwater pumping at the plant for operational purposes, no mention is made of drawdown due to the cumulative effects of St. Francisville and Baton Rouge withdrawals.

Flease provide this discussion along with an analysis of probable aquifer permeability loss due to compaction / subsidence.

i

RESPONSE

The response to this request is proirided in revised Section 2.3.2.1.3.

O l

Supplement 3 Q&R 2.3-24 April 1982

t RBS ER-OLS

[~')

QUESTION E240.32 (App. 2B)

U Evaluate the effects of flooding of Alligator Bayou on erosion of the natural levee between Alligator Bayou and the Mississippi. River.

Estimate the number of additional days per year of overtopping of the levee due to the emplacement I

of the existing culverts.

Describe what this will do to the rate oE erosion of the levee which existed before the construction of the culvert section.

Discuss the sensitivity of the.results of your analysis to assumed levels of culvert blockage of 25, 50, and 75 percent.

j

RESPONSE

l The response to this request is provided in resised Section 4.2.1 and Table 4.2-1.

i 4

i O

i i

f Supplement 3 Q&R 2B-3 April 1982

~

i

RBS ER-OLS QUESTION E240.33 (App. 2B)

Evaluate the effects of flooding of Alligator Bayou on access to the plant's Mississippi River Intake structure.

Take into account the effect of Mississippi River Flooding on access using River Road.

Estimate the number of days per year, on the average, that access to the intake structure is limited due to flooding.

Also discuss what effect (if any) this limited access will have or the operation of the plant.

Discuss the sensitivity of the results of your analysis to assumed levels of culvert blockage of 25, 50, and 75 percent.

RESPONSE

The response to this request is provided in revised Section 4.2.1.

O Supplement 3 Q&R 2B-4 April 1982

RBS ER-OLS CHAPTER 3 LIST OF TABLES (Cont)

Table Number Title 3.5-8 RADIOACTIVE GASEOUS EFFLUENT FROM SOURCES OTHER THAN OFF GAS (CI/YR/ UNIT) 3.5-9 RADIOACTIVE GASEOUS EFFLUENT FROM THE THREE RELEASE POINTS (CI/YR/ UNIT) 3.6-1 EXPECTED COMPOSITION OF REGENERATION WASTES 3.6-2 EXPECTED COMPOSITION OF DISCHARGES TO MISSISSIPPI RIVER

-3.6-3 EXPECTED CONCENTRATION OF HEAVY METALS IN COOLING TOWER BLOWDOWN 3.6-4 EXPECTED CHEMICAL COMPOSITION OF AUXILIARY BOILER BLOWDOWN 3.6-5 EXPECTED STANDBY DIESEL GENERATOR ENGINE O

EMISSIONS AT 100 PERCENT LOAD 3.7-1 MINIMUM CLEARANCES 4

i l

RBS ER-OLS CHAPTER 3 LIST OF FIGURES Figure Number Title 3.1-1 LOCATION OF GASEOUS RELEASE POINTS

>3.1-2 ARTIST SKETCH 3.1-3 VISUALLY SENSITIVE AND INTENSIVE LAND USE AREAS IN THE VICINITY OF RIVER BEND STATION 3.1-4 SIMULATED VIEWS OF RIVER BEND STATION FROM ST. FRANCISVILLE FERRY LANDING e

3.1-5 SIMULATED VIEWS OF RIVER BEND STAT:OM FROM NEW ROADS FERRY LANDING 3.2-1 STATION FUNDAMENTAL FLOW DIAGRAM 3.3-1 WATER USE DIAGRAM (COMBINED TWO UNIT OPERATION) 3.4-1 HEAT DISSIPATION SYSTEM (ONE UNIT) 3.4-2 CIRCULATING WATER FLUME AND PUMPWELL 3.4-3 INTAKE-DISCHARGE AREA EMBAYMENT DEVELOPMENT 3.4-3a ESTIMATED INITIAL SEDIMENT DEPOSITION LOCATIONS IN EMBAYMENT 3.4-4 MAKEUP WATER INTAKE STRUCTURE PROFILE 3.4-5 DISCHARGE PIPELINES TO MISSISSIPPI RIVER 3.5-1 SOLID WASTE MANAGEMENT SYSTEM 3.5-2 RADIOACTIVE LIQUID WASTE SYSTEM 3.5-3 OFF GAS SYSTEM 3.6-la WATER TREATING SYSTEM P&ID 3.6-lb WATER TREATING SYSTEM P&ID 3.6-1c WATER TREATING SYSTEM P&ID 1

Supplement 3 3-vi April 1982

d i

i RBS ER-OLS I

r 1

5 CHAPTER 3 LI,ST OF FIGURES-(Cont) 6 4

~I i

Figure l

Number Title l

4 3.6-2 WASTE WATER TREATMENT P&ID 4

3.6-3 COOLING TOWER WATER TREATMENT i

i i

l 4

1-l 1

l I

f l

I i

i

,I i

l-I f

Supplement 3 3-via April 1982 4

1 l

j i

i,

RBS ER-OLS O

THIS PAGE INTENTIONALLY BLANK O,

Supplement 3 3-vib April 1982

i I

RBS ER-OLS

(

3.4.1.3 Discharges to Mississippi River The Mississippi River will be subject to liquid discharges during plant operation.

Discharge from the heat dissipation system will consist of blowdown from the main cooling water system.

Additions to this flow are treated liquid radwastes and neutralized demineralizer wastes.

The thermal aspect of r

the discharge is covered in this section.

Sections 3.5 and l

3.6 complete the description of the discharge characteristics.

F The rate of blowdown from the main cooling water system into i

the Mississippi River will be constant depending on the i

number of station units operating.

I Blowdown discharge flow

rate, temperatures, and concentration factors are listed on the basis of monthly averages in Table 3.4-2.

The two-unit discharge is a

coastant 4,400 gpm, with a maximum temperature of 960F.

A i

discussion of thermal plume predictions is contained in Sectirn 5.3. 2.1.

3.4.1.4 Discharges to Air At the design condition, the mechanical-draf t cooling towers require approximately 90 x 106 cfm of ambient air to

(' x) dissipate the waste heat from River Bend Station.

About 1,950 MWt of waste heat will be dissipated to the atmosphere i

from each unit.

Since the air passing through the cooling tower is mechanically

induced, the discharged airflow remains fairly constant.

Exit air temperatures are proportional to the wet-bulb temperature of the ambient air.

The mechanical-draft cooling towers planned for use at the River Bend Station site are expected to provide the only plant effluents with a

potential for influencing local meteorology.

The effluent types of concern are commonly described as visible plumes (fog) and cooling tower drift.

Each of these effluent types and their impacts on local j

weather are described in Section 5.3.3.

i 3.4.2 Component Descriptions 3.4.2.1 Intake System 1

The cooling tower makeup water system is composed of three parts:

river intake screens and

piping, pumphouse, and piping from the pumphouse to the clarifiers at the plant site.

The cooling tower makeup water treatment plant is discussed separately in Section 3.6.

()

3.4-3

RBS ER-OLS The intake screens and piping and a barge slip for barge unloading are located in a

man-made recession on the Mississippi River near River Mile 262 (Fig. 3.4-3).

The recession is approximately 600 ft in length along the river by 450 ft in width, with a dredged bottom at el -12 ft msl.

The recession design is based on model studies conducted by Colorado State University and described in FSAR Appendix 2E.

Four recessions of varying configuration were modeled to determine the characteristics of surface and bottom velocities, sedimentation, surface debris accumulation, recirculation potential, and intake back-flushing.

Bank Recession Model 4 (FSAR Appendix 2E) was selected as the prototype for the River Bend Station embayment on the basis of its preferred performance characteristics.

3 The blowdown discharge line is located downstream of this recession to avoid recirculation.

FSAR Appendix 2E states that an outfall location downstream of Section x = 61.0 ft (model scale) in Bank Recession Model 4 would prevent recirculation.

This is based on studies of velocity patterns at

low, normal, and high iver stages.

Appendix 2E, Fig. VI-38, shows the Model I configuration.

In comparison with FSAR Fig. 2.4-30, the embayment has been constructed about 100 ft downstream of the Model 4 layout, requiring a downstream outfall location of about model scale x = 62 ft.

The

outfall, shown on FSAR Fig. 2.4-30, is at about model scale x = 67 ft and beyond the effect of recirculation.

The entrance to the pumphouse structure is at el +60 ft-6 in msl to protect pumps and motors from the project design flood level with wave runup.

Three pumps, each sized for 16,000 gpm, are housed inside the structure.

The pumps are mounted at floor el +10 ft-O in msl and their columns extend to floor el -15 ft msl at their suction elbows.

River water is conveyed to the pumps by two suction pipelines leading to a

common manifold within the pumphouse structure.

A wedge-wire intake screen is mounted at the entrance to each suction pipeline.

The intake screens are octagonal shaped and are sized so that the average entrance velocity is less than 0.5 fps.

The velocity of the water flowing by the intake screens will be approximately 0.1, 0.2, and 0.7 fps at low, average, and high water river stages, respectively.

These flows will not affect operation of the pumps.

If fouling occurs, the screens will be cleaned by backwashing facilitated by the backwash connection located at el 18 ft mst in the pumphouse structure.

Based on studies presented in FSAR Appendix 2E, the neck-3 shaped portion of the bank along the upstream end of the Supplement 3 3.4-4 April 1982 g

RBS ER-OLS

[)

recession minimizes the amount and rate of sed.iment

\\/

deposition and trash carried into the recession.

FSAR Appendix 2E Fig. VI-56 and VI-58 show the predicted locations in Bank Recession Model 4 of surface debris accumulation and initial sediment deposition, respectively.

Fig. 3.4-3a shows the estimated initial sediment deposition locations for the River Bend Station embayment, based on the Model 4 results.

It can be seen that initial deposition is not in the immediate intake area.

From FSAR Appendix 2E, the predictea yearly sediment transport into the Model 4 recession is about 14 acre-ft.

The distribution of this sediment will not be uniform throughout the embayment, but should tend to follow the pattern of initial deposition.

The base of each intake screen is at el -7.5 ft msl, giving a normal separation of 4.5 ft to the embayment dredged bottom.

With this separation and the estimated sedimentation rate, it is anticipated that monitoring and subsequent sediment removal will be required every other year to minimize any impact to intake operation.

However, the interval between embayment soundings will be modified to correspond to the rate of embayment sedimentation incurred during station operation.

3 As discussed in this appendix, the rate of sedimentation in the recession is dependent on the amount of sediment carried

(N) along the east bank.

Data from water quality sampling sites along the Mississippi River have generally shown that the concentration of sediment is only slightly greater in the river channel than along the

banks, as discussed in Section 2.3.3.1.1.

Therefore, the rate of embayment sedimentation is directly related to the overall river sediment

load, and the seasonal fluctuation in embayment sedimentation can be expected to follow the pattern of river sediment load.

The sediment transport capability of the river flow is proportional to the velocity; therefore, floods carry larger amounts of suspended sediment.

Data from the river reach including the site verify

this, with annual spring floods producing the highest river sediment loads.

Extreme floods such as have occurred in 1973,

1974, and 1975 have the potential to increase the embayment sedimentation rate above the predicted magnitude.

The sedimentation monitoring schedule will consider the impact of extreme floods.

As discussed in Section VII of FSAR Appendix 2E, extreme floods have the potential to modify channel bathymetry and hydraulic characteristics.

The flood of 1973 caused a shift in channel thalweg away from the embayment toward the channel center.

The result was a measured reduction in

/~Lj)

Supplement 3 3.4-4a April 1982

/

RBS ER-OLS post-flood channel velocity near the embayment and a

predicted reduction in embayment sedimentation.

Comparison and analysis of recession monitoring records can identify shifts in the sedimentation rate and will be used to establish the interval between embayment soundings.

Based on makeup water pump design and operating conditions, the potential for loss of makeup water laading to interruption of normal power generation due to sediment-induced cavitation in the intake pumps is considered non-existent.

Cavitation, as normally associated with a pump, can be defined as the formation of vapor bubbles in the low-pressure (suction) end of the pump which collapse in the high-pressure (discharge) end and subject the pump to liquid hammer.

If left uncontrolled, cavitation will lead to undesirable conditions such as pitting and excessive vibration.

To prevent cavitation, the available net positive suction head (NPSH) must be greater than the required NPSH specified by the pump manufacturer.

Since the system design includes provision for more than the minimum required NPSH to be available over the full range of operating conditions, cavitation is not expected to occur.

Turbidity in the working fluid will affect the rate of wear of the pump parts in

contact, but will not lead to 3

cavitation as previously defined.

At higher levels of suspended solids, more abrasion and wear of the metal will

occur, causing a

decreased pump life.

If a makeup water pump fails to produce the required flow, it will be taken out of operation.

A spare full-flow pump is available (F.aR Section 9.2.11.2).

Any interruption of makeup water flow would be temporary and not of sufficient duration to interrupt normal power generation.

The makeup water pumps are capable of operating at the desired rate over the entire range of suspended solids expected in the makeup water without failure due to significant pump abrasion, clogging, or mechanical failure due to high loads or impact shocks.

The ambient suspended solids level of Mississippi River water near St. Francisville averages 163 ppm annually, with a

reported monthly maximum of 463 ppm (Table 3.6-2).

These levels are generally representative of the river water at the depth of the intake structure.

Data are based on a monthly sampling program conducted by USGS at St. Francisville and do not reflect temporary turbidity excursions up to the 2,500 ppm detected by the U.S.

Army Corps of Engineers at Red River Landing and Baton Rouge.

Turbidity, as determined by USGS, will be used to determine ambient levels and trends.

Normally, ambient turbidity Supplcment 3 3.4-4b April 1982 ll

RBS ER-OLS I~ \\

should correlate with turbidity of the water pumped for cooling tower makeup.

Monitoring of sedimentation deposition in the embayment area will be conducted periodically, and sediment removal will occasionally be required.

This will prevent excessive sediment buildup from causing a

higher than ambient level of turbidity in the makeup water.

Turbidity of the makeup water is continuously monitored and recorded at the inlet to each clarifier 3

(Section 3.6.1.2).

Each turbidity analyzer is set to alert the operator of abnormally high turbidity by annunciating on the water treatment system control panel.

Based on the recorder

charts, the operator can determine whether any action is required (such as adjusting the chemical feed or sludge recirculation rate) or if the rise is a transient condition requiring only surveillance.

The expected level of suspended solids in the makeup water under all conditions will not affect operation of the makeup water

pumps, clarifiers, or other system components.

The intake screens and suction piping are supported by 12-in-diameter steel friction piles driven to the Holocene sands.

Fig. 3.4-4 shows a

profile view of the intake screens and suction piping leading to the pumphouse.

The pipe support members between the piles do not extend above el +0.25 ft msl.

The pile memoers support the suction r~~

pipelines to the recession slope, after which the pipelines

(,)

are buried until entering the pumphouse structure.

Riprap is placed to minimize possible erosion of the natural bank which covers the suction pipes.

The barge slip consists of a graded gravel platform with a 10:1 slope.

This unloading facility will allow a barge to be grounded and the cargo directly unloaded.

?

f~

Supplement 3 3.4-4c April 1982 U

w' RBS ER-OLS O

THIS PAGE INTENTIONALLY BLANK O

Supplement 3 3.4-4d April 1982

i

/

i

/

i T

f

\\\\'

PUMP HOUSE 9 MAKEUP WATER

) MAKEUPW ATER STRUCTURE V ALVE CH AMBEb

/

i I;

j f

h

/

/\\/

l 4

/

/

/

/

~'/

/g

/

\\s i

S

,4

/

/

j INTAKE I

SCREENS

/,/

i j

l l

l l

~ _______

BOTTOM CONTOUR _

BARGE SLIP

/

E L.-12 '

O -'

i

~ '

N

-1 m

i i

I s

N P

l

'\\,

,f '

/

t_

'N

\\

J N.,\\r / :

j

/

0 x

O b

y' '\\

gO s

,/'

O gO

/

.~.

7'

-_,J

?~

Sggn J

oO [

copy

$@2 -

\\

/

CHAD.

. g/

/

l ao" DI A. COOLING TOWER 09

/ BLOWDOWN PIPE

$ gt

/

y -

6" DI A. S LU D G E g'

/

ELOWDOWN PIPE FIG. 3.4-5 jNATURAkRIVER BANK I

l

\\x

4/p

  1. O PLANT NORTH

[74

\\

N

\\

x ea x

\\p 0

x

'N 4,,

x 1Nc -

x Rt,,g QER N

N s

\\l 1

1 x

s

\\

x__

Z

'~

INITI AL 1

1 l

SEDIMENT Y

DEPOSITION 0

g 9

go \\tg, f

y g

4 go 0

Y9 sO O',9sh-S O

5,0 100 200 p

O@

g%

SCALE IN FEET

%\\N E BLOWDOWN O

ER FIGURE 3.4-3a 00 3,3 ESTIMATED INITIAL SEDIMENT DEPOSITION LOCATIONS IN EMBAYMENT RIVER BEND STATION ENVIRONMENTAL REPORT-OLS SUPPLEMENT 3 APRIL 1982 jo

4 i

RBS ER-OLS CHAPTER 3 QUESTIONS AND RESPONSES I

4 TABLE OF CONTENTS

.l I

NRC Supplement

-Q&R l

Question No.

No.

Page No.

i E240.16 1

3.3-1 E240.17 1

3.3-2 f

~

E291.5 2

3.4-1 E240.29 3

3.4-2 E240.30 3

3.4-3

?

i E460.1 1

3.5-1 E240.18 1

3.6-1 E240.19 1

3.6-2 E291.6 2

3.6-3 E291.7 2

3.6-4 j

E290.7 2

3.7-1 r

1 i

4 1

j t

i i

i

?'

i i

r i

l i'

i Supplement 3 Q&R 3-i April 1982 4

.~

... -. ~,.. -,

... ~,

L RBS ER-OLS 3

l t

F QUESTION E291.5 (3.4) i Indicate whether thermal and/or chemical treatments will be used in the backwash treatment of the intake structure.

RESPONSE

t

'No design provision is included for thermal and/or chemical j

treatments in the backwash of the intake structure.

i i

t i

i

)

r I

I t

I i

I h

I t

I I

i t

?

i i

?

I t

Supplement 2 Q&R 3.4-1 March 1982 i

1 l

l i

RBS ER-OLS QUESTION E240.29 (FSAR 2.4.11.5/ER-OLS 3.4)

It is stated that sandbars form gradually along the passageway upstream of the makeup water intake structure embayment.

Provide drawings showing the configuration of the embayment and bargeslip, indicating location and aerial extent of candbar growth.

RESPONSE

The response to this request is provided in revised Section 3.4.1.2 and Figure 3.4-3a.

See also response to Question E240.28.

O Supplement 3 Q&R 3.4-2 April 1982 g

RBS ER-OLS.

(~h QUESTION E240.30 (FSAR 2.4.11.5/ER-OLS 3.4) s-It is stated that with periodic maintenance dredging, intake operation is unaffected by sediment and that soundings of the makeup water intake embayment will be performed periodically, but not less thad' once every other year.

Discuss the extent to which sandbar growth can occur during significant floods of fairly long duration such as those.

that occurred in 1973, 1974, and 1975 and how the occurrence of such a flood is accounted for in the scheduling of sediment deposition monitoring.

l

. RESPONSE The response to this request is provided in revised Section 3.4.1.2.

t f

O 4

I UPP ement 3 Q&R 3.4-3 April 1982 l

+

,n_,

.,_,,_.g.

i RBS ER-OLS

[}

CHAPTER 4 V

ENVIRONMENTAL IMPACTS OF CONSTRUCTION TABLE OF CONTENTS

[

Section Title Page 4.1 LAND USE IMPACTS 4.1-1 4.1.1 The Site and Vicinity 4.1-1 4.1.1.1 The Site 4.1-1 4.1.1.2 The Vicinity 4.1-2 4.1.2 Transmission Corridors and Offsite' Areas 4.1-2 4.1.3 Historic and Archaeological Sites 4.1-3 4.1.3.1 The Site and Vicinity 4.1-3 4.1.3.2 Transmission Corridors and Offsite Areas 4.1-3 L

i 4.2 HYDROLOGICAL ALTERATIONS AND WATER USE IMPACTS 4.2-1 4.2.1 Hydrological Alterations 4.2-1 4.2.2 Water Use Impacts 4.2-4a 3

4.2.2.1 Construction Effects on Water Quality 4.2-4a

-s 4.2.2.2 Construction Effects on Water Use 4.2-5 v

)

4.3 ECOLOGICAL IMPACTS 4.3-1 I

4.3.1 Terrestrial Ecosystems 4.3-1

[

4.3.1.1 The Site and Vicinity 4.3-1 i

4.3.1.2 Transmission Corridors and Offsite Areas 4.3-4 4.3.1.2.1 Impact on Vegetation 4.3-4 i

4 4.3.1.2.1.1 Route I 4.3-4 g

4.3.1.2.1.2 Route II 4.3-6 4.3.1.2.1.3 Route III 4.3-8 4.3.1.2.1.4 Summary 4.3-9 4.3.1.2.2 Impact on Wildlife 4.3-10 4.3.2 Aquatic Ecosystems 4.3-11 4

+

4.3.2.1 Site and Vicinity 4.3-11

?

4.3.2.2 Transmission Corridors and Offsite Areas 4.3-14 4.4 SOCIOECONOMIC IMPACTS 4.4-1 4.4.1 Physical 4.4-1 4.4.2 Social and Economic Impacts 4.4-2 4.4.2.1 Income, Taxes, and Employment 4.4-2 4.4.2.2 Construction Work Force Impacts 4.4-4 O

Supplement 3 4-1 April 1982 t

-m w

-,n-, -

RBS ER-OLS CHAPTER 4 TABLE OF CONTENTS (Cont)

S ection Title Page 4.5 RADIATION EXPOSURE TO CONSTRUCTION WORKERS 4.5-1 4.6 MEASURES AND CONTROLS TO LIMIT ADVERSE IMPACTS DURING CONSTRUCTION 4.6-1 4.6.1 Noise 4.6-1 4.6.2 Erosion 4.6-2 4.6.3 Dust 4.6-3 4.6.4 Traffic 4.6-3 4.6.5 Effluents and Wastes 4.6-4 4.6.6 Surface Water 4.6-5 4.6.7 Groundwater 4.6-5 4.6.8 Land Use 4.6-6 4.6.8.1 Site and Vicinity Land-Use Protection /

Restoration 4.6-6 4.6.8.2 Offsite Land-Use Protection 4.6-7 4.6.9 Terrestrial Ecosystems 4.6-7 4.6.10 Aquatic Ecosystems 4.6-8 4.6.11 Socioeconomic Impacts 4.6-8 4.6.12 Radiation Exposure to Construction Workera 4.6-8 4-11

._=

t 1 --

l

~

RBS ER-OLS I

i J

' CHAPTER 4 LIST OF TABLES i;

Table Number Title i

4.2-1 CULVERT BLOCKAGE AT ALLIGATOR BAYOU BASIN a

i t

4.3-1 ONSITE AREAS CLEARED FOR MAJOR CONSTRUCTION 4.3-2 VEGETATION AFFECTED BY ONSITE CONSTRUCTION 1

i I

LIST OF FIGURES Figure Number Title f

4.2-1 SITE AREA PONDS g

4.3-1 AREAS AFFECTED BY CONSTRUCTION i

l i

f i

l 4

i-r l

i i

i l'

i e

i

)

i i

I 1

l t

i

(

l j

I Supplement 3 4-111 April 1982 l

L i

I i

{

t

RBS ER-OLS

(}

4.2 HYDROLOGICAL ALTERATIONS AND WATER USE IMPACTS 4.2.1 Hydrological Alterations Groundwater Alterations No irreversible alterations to the groundwater table in the site area were made during the initial phase of the construction dewatering

program, which took place between May 11, 1976 and May 23, 1977.

During this

period, the groundwater level in the Upland Terrace Aquifer was drawn down -about 60 ft.

Dewatering was accomplished by 44 12-in-dianeter wells, each equipped with a 700-gpm pump.

Maximum dewatering flew was about 21,700 gym (48.3 cf s), and the average value was 7,700 gym (17. 2 cf s).

Groundwater levels after construction are sirilar to the preconstruction levels.

Piezometer readings made at the site 1 yr after completicn of this period of dewatering showed that the cone of depression had disappeared, the natural groundwater gradient had

returned, and the groundwater level had recovered to within 10 ft of the preconstruction level.

A second period of dewatering ccmmenced in May 1979 at an average daily rate of about 3,000 gpm (6.7 cf s).

It is anticipated that the dewatering system will be shut dcwn by April 1981 and will then not te further required during Unit 1 construction.

From the experience gained during the first O-dewatering period, as discussed in Section 2.3.2.1.4, it is estimated that the groundwater level will recover in a

similar manner to the first dewatering period.

Surface Water Alterations Station construction has altered the natural surface water hydrclogical setting.

Features of these alterations are depicted in Fig.

2.1-3.

Dewatering flow was conveyed frcm the plant area to Grants Bayou.

This has caused nc irreversible impact to that stream.

The annual flood fcr Grants Bayou is in excess of 1,000 cfs, and storms frequently cccur in the basin which i

produce streamflows greater than the dewatering flow.

No significant impact to channel characteristics has been detected from the routing of dewatering flow to Grants Bayou.

River Access Road, located between the intake embayment area on the Mississippi Riser and the plant area, is constructed across Alligator Bayou on the ficcdplain of the river.

This road was constructed for the purpose of providing access to the embayment area and for the transpcrtation of heavy

()

4.2-1

RBS ER-OLS construction

loads, and will remain during the operational phase of the plant.

Fourteen 6-ft-diameter corrugated-metal culverts are provided in the road embankment to allow overbank Mississippi River flood flow and Alligator Bayou flow to pass from the upper bayou to the lower bayou according to the preconstruction pattern.

A description of the estimated hydrological impact of construction of River Access Road is provided in Appendix 2B and Section 4.3.2.

In addition to the study presented in Appendix 2B, an analysis was performed to determine, in greater detail, the potential impact of culvert blockage during a storm in the Alligator Bayou basin.

Culvert blockage was assumed at 0,

25, 50, and 75 percent.

Table 4.2-1 presents the results.

It can be seen that culvert blockage slightly increases the overtopping duration.

However, it has a

relatively insignificant effect on Upper and Lower Bayou water levels, because the conveyance of the overtopped portion of River Road is sufficient to carry the peak portion of a site flood with relatively low head at River

Road, stabilizing the bayou water level.
However, overtopping the levee for these intermittent and relatively short periods erodes a

100-to 150-ft-long section of River Road and forms gullies between the road and 3

the Mississippi River.

Erosion is localized and will not impact the overall levee erosion rate in the area.

Additionally, installation of the Army Corps of Engineers revetment in the near future will stabilize the river bank and minimize the impact of levee overtopping.

In an effort to mitigate road

washouts, erosion repair work has been performed to maintain the existing road profile and prevent extension of erosion gullies back into Alligator Bayou.

Based on the performance of the culvert emplacement to date, it is anticipated that a continued program of surveillance and erosion repair will maintain River Road and the surrounding area during the period of station construction.

Alternative drainage schemes at River Access Road may be investigated during plant operation if levee overtopping and erosion prove extensive and not easily controlled by maintenance.

An excavated embayment has been constructed in the Mississippi River along the east bank at about River Mile 262.5.

A barge slip and the plant makeup water intake screens are located in the embayment, which provides protection from main channel debris and navigation.

Access to the embayment area is obtained from the north and south Supplement 3 4.2-2 April 1982

RBS ER-OLS

(~'/

)

by River

Road, which runs parallel to the river along the

\\_

natural levee, and from the east (and the plant area) by River Access Road.

Embayment banks are gently sloped and employ riprap protection to -12 ft mal (about 19 ft below mean low water level) to reduce the effects of river bank erosion.

Riprap stone size is 16 to 20 in.

The natural bank erosion rate (no slope stabilization) is estimated to be 8 ft/yr (Section 2.3).

By agreement with the Army Corps of Engineers, dredged material from embayment construction has been deposited at acceptable bed elevations in the river.

Bottom elevation in the embayment is -12 ft msl.

Periodic dredging of the embayment may be required due to sediment transport in the river (Section 2.3).

The effect on access to the intake structure due to floods on Alexander Creek / Alligator Bayou and the Mississippi River has been evaluated.

River Access Road is the primary access route from the station to the intake structure on the river.

While access to the intake is possible via River Road along the levee, there are currently no plans for use of this route by station personnel.

Therefore, the impact of flooding on River Road access to the intake structure is not a significant concern.

The potential for culvert blockage at River Access Road has

("N no impact on intake structure access.

The levee along the

)

river is at a lower elevation than River Access Road.

Flood g

flow unable to pass through the culverts due to blockage would pond in the Upper Bayou and flow over the levee to the river prior to topping River Access Road and inhibiting intake structure access.

3 River Access Road has a finished grade of 50 ft msl across the bayou and at the intake embayment.

The entryway to the intake structure is at 60.5 ft.msl, 10.5 ft above finished grade.

Based on a study of historical stage (1956-1979) at Bayou

Sara, LA, 3 mi upstream of the site, the following information is applicable to the Mississippi River at the River Bend Station embayment (see Section 2.3 for a detailed description of site hydrology):

Mean annual stage 20.4 ft mal Mean annual flood 38.9 ft msl 10-yr flood 46.4 ft msl 25-yr flood 50.4 ft msl Project design flood 54.5 ft msl Maximum daily recorded stage 52.1 ft mal Maximum monthly average recorded stage 49.2 ft msl Exceeding 40 ft msl 5% (18 days /yr)

Exceeding 45 ft mal 1% (4 days /yr)

[)

Supplement 3 4.2-2a April 1982

\\

J v

a 4

RBS ER-OLS Exceeding 50 ft mal

<1%

gg Based on a

statistical review of the stage data, it is estimated that access to the intake structure via River Access Road may be limited for 1 to 2 days per year.

The data base includes four of the most severe floods in recorded history (1973, 1974, 1975, and 1979); however, the water level at the site exceeded 50 ft ms1 during only two 3

periods in the 24-yr data base, the two greatest Mississippi River floods which occurred in 1973 and 1979.

It is anticipated that the slight potential for limited access to the intake structure will have no impact on station operation.

The intake structure can be accessed by a boat if necessary during a flood period.

Intake system hydrodynamics and flow patterns in the embayment are discussed in Section 5.3.1.

The cooling tower blowdown pipeline and the clarifier sludge discharge pipeline exits the plant area adjacent to one another and cross Alligator Bayou along the south side of River Access Road.

Both pipes exit to the Mississippi River within the riprapped portion of the river embankment, approximately 400 ft downstream from tne centerline of the embayment.

The pipelines are buried in the roadbed and do not interfere with surface water flow in Alligator Bayou and West Creek.

The discharge outfalls are discussed in Section 3.4.

Potential impacts of discharge from these pipelines are discussed in Sections 5.3.2 and 5.5.

The centerline of both outfalls is at

-3 ft msl, about 10 ft below mean low water.

There is no impact to river navigation.

A reach of Wert Creek in the plant area has been relocated to a 2,850-ft-long Fabriform-lined channel to reduce the potential for erosion and plant flooding due to local Supplement 3 4.2-2b April 1982

p RBS ER-OLS i

l storms.

Creek flow is directed into the lined channel by a

drop structure.

Channel slope is approximately 0.002 ft/ft (0.2 percent).

The channel cross section is trapezoidal with a 10-f t depth, bottom width of 50 f t, and 3H : 1V side slopes.

The interface of the downstream end of the lined channel and the existing stream bed is protected by riprap j

to minimize channel undercutting.

Plant construction has resulted in the removal of all but about 750 ft of East Creek, a small debris-clogged drainage course formerly about 3,500 ft long.

An additional 1,150 ft of unlined channel, which drains to East Creek, will convey sewage treatment plant effluent (less than I cfs) and storm water runoff to Grants Bayou.

North Access

Road, constructed to permit plant access to State Highway 965 and US Highway 61, passes over West Creek about 1,500 ft upstream of the drop structure and over West Fork Grants Bayou about 2,000 ft upstream of the plant area.

The bridges at these points have no significant effect on water levels at either stream due to bridge size and height i

above normal and flood levels.

Prior to construction, 24 ponds existed within the site property boundary with a

total surface area of about 28.6 acres.

Five ponds were removed during construction 3

having a combined total surface area of about 1.7 acres.

j Fig. 4.2-1 shows the location of ponds within the site property boundary.

To offset the removal of these ponds, one pond, called the Wildlife Management Lake, will be constructed at the River Bend site.

Normal water surface elevation will be about 50 ft ms1.

This water level will be controlled by a

concrete spillway about 26.5 ft wide located at the tramway bordering Alligator Bayou.

At this water level, the surface area is about 34.2 acres, storage is about 196 acre-ft, and the average. depth is slightly less than 6 ft.

The spillway embankment will be constructed from onsite construction i

spoil material.

Access to the lake will be constructed from River Access Road.

The final plans for future use of the i

lake are being investigated.

A variety of erosion control measures have been implemented i

at the site during, plant construction, including the stockpiling and use of topsoil, seeding, mulching, drainage channels, and energy dissipators.

Site soils are highly erodible.

Sediment deposition due to runoff from the primary spoil pile has occurred in the Wildlife Management Lake and in a

small portion of the floodplain near the

/s

4. 2-3 f

U r

l' 1

RBS ER-OLS tramway entrance to the lake.

Sediment deposition due to runoff from plant construction areas has also occurred in portions of East Creek and West Creek.

The drainage and water quality characteristics of these streams have not been significantly altered.

Mitigative action taken to minimize erosion is discussed in Section 4.6.

During the final phase of plant construction and the initial phase of operation, all areas cleared for construction or used as stockpile and equipment laydown areas will be replanted with vegetative cover to minimize erosion.

Vegetative cover will also be used to restore and stabilize any areas affected by erosion and deposition of eroded sediments.

This will involve the use of grass seed, lime and fertilizer, mulch, binding or mulch anchoring,

topsoil, fill,
sod, flumes, drainage
ditches, and/or energy 3

dissipators, and other appropriate measures as necessary.

All seed will comply with guidelines published in the Louisiana Standard Specifications for Roads and Bridges (28 Onsite erosion will be monitored and controlled as described laboveandinSection4.6.

1 Sediment production (erosion) and deposition caused by construction of the

plant, the intake and outfall structures, the barge
slip, or River Access Road are not expected to have any residual adverse impact upon plant operation, since these and adjoining areas will be restored to minimize erosion and subsequent deposition.

Periodic 1

dredging in the embayment area will be necessary and will result in a temporary increase in suspended solids in the intake water which will be removed by the clarification system (Section 3.6.1.2).

Improvements to the riverbank bordering the River Bend site are planned by the U.S. Army Corps of Engineers to begin in 3

the fall of 1984 and be completed in early 1985 (Section 4.6.2).

No significant adverse operational impact is expected to result from these activities.

Co,nve rsely, the revetments will have a

beneficial effect through stabilization of the riverbank.

The erosion protection provided in the design and construction of the embayment area was engineered to take into account U.S.

Army Corps of Engineers plans and methods for revetment in order to ensure 3

continuity at the connecting points.

Since it was not a factor in the functional design of the embayment

area, revetment construction is not expected to impact plant operation should the improvements be delayed until after plant operation begins.

Supplement 3 4.2-4 April 1982

RBS ER-OLS ps

(

')

There are no significant hydrological alterations offsite or

(.s/

within the transmission corridors due to plant construction.

4.2.2 Water Use Impacts 4.2.2.1 Construction Effects on Water Quality There are no irreversible effects on the regional water quality due to plant construction activities.

The major effect of the construction activities was the temporary increase in the turbidity of East and West

Creeks, due to storm runoff from land areas cleared for construction.

Wastewater from the concrete batch plant has been discharged to Upper West Creek after being treated in the wash pits.

Discharge to the wash pits has been about 500 gpd (0.001 cfs).

Construction waste streams are periodically inspected to ensure compliance with NPDES permits.

A 1

discussion of construction effluent monitoring is included in Section 6.6.

During embayment construction, an increase in the turbidity of flississippi River water, due to dredging

activity, was localized and temporary.

A discussion of sediment added to the river during embayment construction is presented in Section 4.3.A.1.

r^'T t

\\

N.,/

l l

[']

Supplement 3 4.2-4a April 1982

'O

RBS ER-OLS O

THIS PAGE INTENTIONALLY BLANK O

i Supplement 3 4.2-4b April 1982

.___a

RBS ER-OLS TABLE 4.2-1 CULVERT BLOCKAGE AT ALLIGATOR BAYOU BASIN i

Percent Culvert Rainfall Recurrence (years)

Blockage 1

5 10 2

t Ea To l

Es E

To E

Ea To E

O 38.5 33.1 11 39.8 34.8 20 40.2 35.8 23 l

25 38.5 33.1 11 39.9 34.8 20 40.2 35.6-23 i

50 38.5 33.1 13 39.9 34.7 21 40.2 35.5 25 t

75 38.5 33.0 14 40.0 34.7 23 40.3 35.4 26 Es = maximum water surface elevation in Upper Bayou (ft mal)

E

= maximum water surface elevation in Lower Bayou (ft ms1) 2 To = hours of flow overtopping the River Road i

Notes:

1.

Fourteen culverts at River Access Road were considered (as installed) i 2.

Minimum River Road elevation approximately 37.3 ft msl 1

l' t

~

i f

[

i i

?

L u

Supplement 3 1 of 1 April 1982

... ~. -. - - _. -

4 i

RBS ER-OLS I

~*

i i

CHAPTER 4 i

l QUESTIONS AND RESPONSES l

i i

I i

TABLE OF CONTENTS

\\

I NRC Supplement Q&R i

Question No.

No.

Page No.

j

?

I E240.20 1

4.2-1 1

E291.14 2

4.3-1 4

E240.31 3

4.5-1 l

E291.8 2

4.6-1 E291.9 2

4.6-2 i

i 1

4 i

i

O I

t i

i I

i L

4 i

A i

.t I

l t

1, f

Supplement 3 Q&R 4-i April 1982 j

l i

l l

l I

t i

I

}

RBS ER-OLS

}

QUESTION E240.31 (4.5.2)

Discuss the. status of Army Corps of Engineer's plans to construct revetments extending upstream and downstream of the makeup water intake structure.

Also describe potential impacts of this construction if it is delayed until after the plant begins operation.

RESPONSE

The response to this request is provided in revised Sections 2.3.1.1 and 4.2.1.

Supplement.3 Q&R 4.5-1 April 1982

RBS ER-OLS

( ') -

Effluent BOD (5-day) and

<30 mg/l suspended solids The sanitary waste system will discharge an estimated 10,500 gpd (0.016 cfs) of secondary treated effluent into the storm drainage system during normal station operation.

Nonradioactive and oil-stripped floor and equipment drainage will add an estimated 43 gpm (0.1 cfs - intermittent flow expressed as continuous flow) to the storm sewer during normal operation.

The treated effluent stream will frequently represent the total flow in Grants Bayou due to the intermittent nature of natural flow.

It is estimated that station sanitary waste treatment plant effluent will comprise all or most (i.e.,

50 percent or more) of the flow in Upper Grants Bayou at least 70 percent of the time.

For the remainder of the time (up to 30 percent), rainfall runoff from the upper bayou drainage area will exceed the treated effluent flow.

The duration that this will occur will vary according to the length and intensity of each rainfall event.

During periods of high makeup water demand, the well water pumps will operate continuously and an intermittent overflow to the storm sewer system of excess well water is expected to occur at an estimated average continuous rate of 4 gpm.

l/_ I s_/

The water quality of plant effluents discharged to local streams is expected to be within NPDES discharge limitations and will not violate state water quality critera.

Sludge resulting from clarification of the cooling system makeup water will be diluted to a solids concentration of 0.5 to 4.0 percent by weight and discharged to the Mississippi River at an average rate of 540 gpm (1.2 cfs).

The sludge consists of raw river water, coagulated suspended solids, and a small amount of cationic polymer which serves as the electrolyte during flocculation.

Considering the composition of the blowdown, the turbid nature of the river, and the presence of rapid mixing characteristics, it is estimated that the clarifier sludge discharge plume will be indistinguishable in the river within 61 to 91 m (200 to 300 ft) of the outfall.

The U.S.

Environmental Protection Agency and the Louisiana Stream Control Commission have approved the discharge of clarifier sludge to the Mississippi River at River Bend Station (2)

Dredging may be required periodically in the intake embayment due to the heavy sediment load in the Mississippi River.

Disposal will be the same as for embayment construction, that is, dredged material will be'placed below p)

Supplement 2 5.5-3 March 1982

,v e

RBS ER-OLS biota resulting from the thermal component of these discharges is discussed in Section 5.3.2.2.

The impact potential of the chemical constituents of these effluents is discussed here.

The largest plant effluent source is the cooling tower blowdown stream which diacharges to the Mississippi River downstream of the intake embayment.

The chemical makeup of this stream is determined by the ambient river water quality (as treated and concentrated in the cooling system), and by the addition of other effluent streams resulting from station operation.

Table 5.5-2 lists the composition of this blowdown stream based on cooling tower concentration of ambient river water, and significant additions to the stream.

Table 5.5-3 compares estimated concentrations of selected dissolved 2

constituents in the station discharge to their biological 3

effect.

For most constituents, maximum concentrations at the point of discharge are well below toxic levels.

Only for iron, calcium, and copper are potentially harmful levels approached under conditions of maximum concentration.

Since average concentrations of iron and calcium are below these

levels, and the effluent is rapidly diluted to ambient levels, these constituents would have no effect on aquatic life.

Average copper concentrations during station operation slightly exceed the 96 hr TLM for bluegill (Table 5.5-3) at the point of discharge.

However, because of the relatively high river velocities at the discharge (1.3 m/sec-4.3 ft/sec average),

it is unlikely that a fish would remain at the point of discharge long enough to be affected.

Rapid dilution takes place, so that within a short distance of the discharge, concentrations will be well below toxic levels.

Furthermore, only a minor portion (conservatively, less than one half) of the estimated copper discharge considered as dissolved in the blowdown stream will appear in the form 2

harmful to aquatic life (i.e.,

ionic form).

This is based on research in regard to ionic copper removal processes and 3

field test data (3)

Copper concentrations above 2 mg/l (Table 5.5-3) could be discharged during the first few months of station operation, due to high initial erosion / corrosion rates of the condenser tubing.

Elevated levels would also occur at other times during station operation when condenser tubing is replaced, but it is unlikely that the initial maximum concentration would be reached unless all condenser tubing is replaced at the same time.

These high copper concentrations would be Supplement 3 5.5-4 April 1982

)

i RBS ER-OLS 1

TABLE 5.8-7 RESIDENCE DISTRIBUTION FOR PRESENT OPERATING STAFF

- West Felicihna Parish I

St. Francisville 20%

f i

I East Feliciana Parish l

l Norwood 2%

i Jackson 23 l

4%

i East Baton Rouge Parish l

Baton Rouge 32%

2 i

Baker 24%

Zachary 14%

Pride J

72%

[

Point Coupee' Parish New Roads 2%

O Jarreau y

4%

i I

Total 100%

i i

I

?

I i

i 4

I t

Supplement 2 1 of 1 March 1982 l

i i

l i

i I

l i

I

-e p---

eww m

m-wd-T r --

r-7--m--

e-

-e-


mr my g

a w

4e,--+eern i

w y-*

e----

er--c-----w-+

v-e---a--

--ypm-g gagw--y mw-

-g

RBS ER-OLS

(~)

Airborne particulate samples will be collected by drawinq

(_/

air at 3 x 10-2 cu m/ min through a filter.

After passing through the

filter, the air passes through an iodine cartridge.

The dust filters will be changed weekly or as required by dust loading, whichever is more frequent.

After standing for 3 or 4 days to allow the daughter isotopes of radon and thoron to

decay, the filters will be assayed weekly for gross beta activity and examined quarterly for gamma isotopes.

Airborne Iodine The indicator and control sampling stations will utilize iodine cartridges, which will be replaced and assayed weekly 1

for radioactive iodine-131.

6.2.1.1.2 Direct Radiation Porty thermoluminescent dosimeter (TLD) stations will be established to measure offsite exposure due to direct radiation.

An indicator station will be located in each of 16 compass directions surrounding the plant at the restricted area boundary.

Another set of indicator stations will be located within a 6-to 10-km range of the site in each of the 16 compass directions.

Five stations will be located in areas of special

interest, such as local O,-

residences, schools, or milk animal pastures.

These special locations are listed in Table 6.2-2.

Three other stations will be maintained as control stations located at a distance of 15 to 30 km in the southwest, east, and north directions.

The indicator stations will contain two TLDs.

One TLD will be replaced and read. monthly, the other quarterly.

The background stations will contain four TLDs.

Two will be replaced and read monthly, the other two quarterly.

6.2.1.1.3 Ingestion Milk Milk appears to be the most direct and the most sensitive means for monitoring iodine-131 (the limiting isotope) in terrestrial pathways.

The known locations of milk animals within a 5-km radius of the plant in 1980 are listed in Table 2.7-115.

Samples from the three locations with the highest dose potential within a 5-km radius will be taken for gamma isotopic and iodine-131 analysis semimonthly when animals are on pasture, and monthly at other times.

These i

locations are 1,600 m northwest, 1,400 m north, and 1,300 m north-northwest from the station.

A sample from milking

}

6.2-3

+. - - - -

RBS ER-OLS animals at a control location 15 to 30 km from the site in a southwest (least prevalent) wind direction also will be W

analyzed at the same frequency.

Food Products Three samples of broadleaf vegetation grown in the offsite locations of the highest calculated annual average ground-level D/Q will be taken for gamma isotopic analysis on the edible portion of the

plant, if milk samples are not available.

This analysis will be done monthly when crops are available.

Samples of broadleaf vegetation will be obtained from a

40 sq m onsite garden with the highest calculated annual average ground-level D/Q, if offsite samples are not obtainable.

The potential radiological impact of station operation on nearby vegetable crops, including the sweet

potato, was reviewed.

No waterborne pathway to man exists via the sweet potato.

Irrigation and surface and ground waters in the 9

station vicinity do not reach the vegetable croplands, since there is no use of Mississippi River water for sweet potato or other vegetable crop.

Impact to vegetables near the station from normal gaseous releases will be insignificant, as discussed in Section 5.4.

The milk pathway provides a greater potential impact to man, and vegetable sampling will be conducted only if milk samples are not available.

6.2.1.1.4 Liquid Discharges Surface Water River water will be collected at the control station located approximately 4.2 km upriver from the plant liquid discharge

outfalls, at the St. Francisville ferry crossing.

River water will also be collected at a point approximately 3.9 km 3

downstream from the plant liquid discharge outfalls, near Crown-Zellerbach paper mill, where the plant effluent is completely mixed with river water.

Composite samples for gamma isotopic analysis will be collected

monthly, and composite samples for tritium analysis will be collected quarterly.

Drinking Water A

monthly composite sample of the raw intake at the first downriver water supply (Peoples Water Service Company Bayou Lafourche, River Mile 175.5) will be collected and analyzed on the same schedule as that of surface water.

Supplement 2 6.2-4 April 1982