Enttrgy Operations, Inc.

River Bend Station 5485 U. S H+ghway 61 O Eh P.O Box 220 St Francisville LA 70775 l

Tel 504 336 6225 l

Fax 504 635 5068 Rick J King Drector Nuclear Safety & Regulatory Aftaas l

May 1,1998 U.S. Nuclear Regulatory Commission Document Control Desk, OPl-17 Washington, DC 20555 i

Subject:

Radioactive Effluent Release Report for 1997 River Bend Station - Unit 1 License No. NPF-47 l

Docket No. 50-458 l

l File Nos.:

G9.5, G9.25.1.5 l

l RBG-44491 RBFI-98-0116 l

Ladies and Gentlemen:

Enclosed is the River Bend Fiation (RBS) Annual Radioactive Effluent Release Report for the period January 1,1997, through December 31,1997. This report is submitted in accordance with the RBS Technical Specifications, Section 5.6.3.

Should you have any questions regarding the enclosed information, please contact Mr. David L

Lorfing of my staff at (504) 381-4157.

l Sincerely, l

/

f'

/

RJK/WJF/BFT/mbp enclosure

\\\\

9605070159 971231 PDR ADOCK 05000458 1

R PDR f%

Q m

.... ~ <

/

l i

}'

- Radioactive Effluent Release Report for 1997 l

May 1,1998 -

l RBG-44491

- RBF1-98-0116 Page 2 of 2_

)

cc:

U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011.

I NRC Resident Inspector l

PO Box 1050 St. Francisville, LA 70775 l

Mr. David L. Wigginton U.S. Nuclear Regulatory Commission M/S OWFN 13-H-3 Washington,DC 20555 l

a

]

,\\

River Bend Station 1997 Regulatory Guide 1.21 April 27,1998 ANNUAL EFFLUENT RELEASE REPORT PREFARED BY:

driali 6. Mar.ts WM DC)SD REVIEWED BY:

  1. f___

' D /V/3 REVIEWED BY:

s I

l}

O APPROVED BY:

/

'Mhh e 6(fL w

sw g

A.D &Oe//s O

e 9

9

Rsver Iknd Sb io 1997 Reguicto,y Guide 1.21 April 27,1998 TABLE OF CONTENTS PAGE I.

INTRODUCTION 3

II.

SUPPLEMENTAL INFORMATION A.

Regulatory Limits 3

B.

Efiluent Concentration Limits 6

C.

Measurements and Approximations of Total Radioactivity 7

D.

Batch Releases 8

E.

Abnormal Releases 9

F.

Estimate ofTotal Error 9

III.

GASEOUS EFFLUENT

SUMMARY

INFORMATION 10 IV.

LIQUID EFFLUENT

SUMMARY

INFORMATION 10 V.

SOLID WASTE 10 VI.

RADIOLOGICAL IMPACT ON MAN 10 VII.

METEOROLOGICAL DATA 11 VIII. RADIOACTIVE LIQUID EFFLUENT MONITORING i

INSTRUMENTATION OPERABILITY l1 IX.

RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION OPERABILITY l1 X.

LIQUID HOLD UP TANKS 11 XI.

RADIOLOGICAL ENVIRONMENTAL MONITORING 11 XII.

LAND USE CENSUS 11 XIII. OFFSITE DOSE CALCULATION MANUAL (ODCM) 11 XIV. MAJOR CHANGES TO RADIOACTIVE LIQUID, GASEOUS AND SOLID WASTE TREATMENT SYSTEMS 12 XV.

PROCESS CONTROL PROGRAM (PCP) 12 1

L

River Bend Station 1997 RegulcWy ouide 1.21 April 27,1998 I

TABLES Table 1 Radioactive Gaseous Waste Sampling and Analysis Program 13 Table 2 Radioactive Liquid Waste Sampling and Analysis Program 14

' Table 3 Gaseous Emuent - Summation of All Releases 15 Table 4 Gaseous Emuent - Conditionally Elevated Releases 17 Table 5 Gaseous Emuent - Ground Level Releases 19 Table 6 Liquid Emuent - Summation of All Releases 21 Table 7 Solid Waste and Irradiated Fuel Shipments 27 Table 8 Maximum Individual Doses Due to Noble Gaseous Releases 29 Table 9 '

Maximum Individual Doses (Gaseous) Doses Due to Gaseous Releases 30 i

Table 10 Maximum Individual Doses (Liquid) 31 Table 11 Assumptions / Parameters for Doses to Member of the Public Inside Site Boundary 32 Table 12 Doses to Members of the Public on Site from Gaseous Releases 33 Table 13 Meteorological Data - Joint Frequency Tables 35 Table 14 Atmospheric Dispersion Factors 68 2

River nend Statia 1997 Regulatc7y Guide 1.21 Apil 27,1998 1.

INTRODUCTION t

i l

This is the annual Radioactive Efiluent Release Report for the period of January 1,1997 through December 31,1997. This report is submitted in accordance with Technical Specification 5.6.3 of Appendix A to River Bend Station (RBS) License Number NPF-47.

l II. SUPPLEMENTAL INFORMATION A. Regulatory Limits 1.10CFR50, Appendix 1 Limits i

a. Fission and Activation Gases In accordance with Technical Requirement 3.11.2.2, the air dose due to ncble l

gases released in gaseous effluent to areas at and beyond the SITE BOUNDARY shall be limited to:

Do.mm..Ai, =

gamma air dose from radioactive noble gases in millirad (mrad) n 3.17E-8 I Mi(7/Q) Qi 5 5 mrads/qtr

=

i=1

$ 10 mrads/yr Du..Ai, beta air dose from radioactive noble gases in millirad

=

(mrad) n 3.17E-8 E Ni(X/Q) Qi 510 mrads/qtr

=

i=1

$ 20 mrads/yr

b. Radiciodine and Particulate In accordance with Technical Requirement 3.11.2.3, the dose to a MEMBER OF THE PUBLIC from iodine-131, iodine-133, tritium and all radionuclides in particulate form with half-lives greater than 8 days, in gaseous efiluent releases to areas at and beyond the SITE BOUNDARY shall be limited to:
Dasop, Dose in mrem to the organ (t) of a specified age

=

group from radiciodine, tritium, and 8 day particulate via

{

the pathway ofinterest.

n P, (X/Q)o Q, and 3.17E-08 (F.) E

=

4 l=1 n

3.17E-08 (F ) I R;,(D/Q) Qi and

=

!=1 3

i J

]

River Bend $1ction 1997 Regulatory Guide 1.21 Apil 27,1993 n

D, I

Danor, 5 7.5 mrem /qtr

=

z=1

> 15 mrem /yr (above terms defined in the RBS ODCM) c.

Liquid Efiluent in accordance with Technical Requirement 3.11.1.2, the dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluent released to UNRESTRICTED AREAS shall be limited to:

D,,

A,,At Oi

=

(DF) D.

a_gs!

n Drorn,=

ID,,

i=1 Drorn,=

Total dose commitment to the organ (t) due to all releases during the desired time interval in mrem and Drorn Total Body 5 1.5 mrem /qtr 5 3 mrem /yr Drorn Any Organ 5 5 mrem /qtr 5 10 mrem /yr (above terms defined in RBS ODCM) 2.

40CFR190 Limits In accordance with Technical Requirement 3.11.4, the annual (calendar year) dose or dose commitment to any MEMBER OF THE PUBLIC, due to releases of radioactivity and to radiation from uranium fuel cycle i

sources, shall be limited to:

5 25 mrem to the total body or any organ (except the thyroid) 75 mrem to the thyroid 4

River Bend Station 1997 Reguktory ouide 1.21 April 27,1998 l

3.

Miscellaneous Limits i

a.

Technical Requirement 3.11.2.1 - Fission and Activation Gases In accordance with Technical Requirement 3.11.2.1, the dose rate j

l due to radioactive materials released in gaseous effluents from the j

i site to areas at and beyond the SITE BOUNDARY shall be less 1

i than or equal to 500 millirems / year (mrem /yc) to the total body and l

less than or equal to 3000 mrem /yr to the skin:

DRre Dose rate to the total body in mrem /yr

=

l n

I Ki (X/Q) Qi 5 500 mrenvjr and

=

l i=1 DRsxm =

Dose rate to the skin in mrem /yr n

I Li+1.lMi (X/Q) Qi 5 3000 mrem /yr

=

l i= 1 (above terms defined in RBS ODCM) b.

Technical Requirement 3.11.2.1 - Radioiodine and Particulate In accordance with Technical Requirement 3.11.2.1, the dose rate j

due to iodine-131, iodine-133, tritium, and all radionuclides in paniculate form with half-lives greater than 8 days released in gaseous effluents from the site to areas at and beyond the SITE BOUNDARY shall be limited to less than or equal to 1500 mrem /yr to any organ:

l DRason =

Dose rate to the organ i for the age pathway group ofinterest from iodines, tritium, ar d 8 day l

paniculate via the inhalation pathway in mrem /yr.

l n

l I Pi (X/Q)o Qi 51500 mrem /yr

=

i=1 I

(above terms defined in RBS ODCM) 5

p River Bend Static 3 1997 Regulatory Guide 1.31 April 27.1998 Technical Requirement 3.11.1.1 - Liquid Emuent c.

In accordance with Technical Requirement 3.11.1.1, the concentration of radioactive material released in liquid emuent to UNRESTRICTED AREAS shall be limited to the concentrations specified in 10CFR20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2.0E-04 microcuries/ milliliter total activity.

d.

Technical Requirement 3.11.2.5 - Ventilation Exhaust Treatment System

{

In accordance w;th Technical Requirement 3.11.. 5, the VENTILATION EXHAUST TREATMENT SYSTEM shall be used to reduce radioactive materials in gaseous waste prior to their discharge when the projected doses, due to gaseous emuent releases to areas and beyond the SITE BOUNDARY would exceed 0.3 mrem to any organ in a 31-day period.

e.

Technical Specification 3.11.1.3 - Liauid Radwaste Treatment System In accordance with Technical Requirement 3.11.1.3, the liquid radwaste treatment system shall be used to reduce the radioactive materials in liquid waste prior to their discharge when the projected doses, due to the liquid emuent, to UNRESTRICTED AREAS would exceed 0.06 mrem to the total body or 0.2 mrem to any organ in a 31-day period.

B.

Effluent Concentration Limits 1.

Gaseous Releases The concentrations of radioactive gaseous releases are based on the dose rate restrictions in RBS Technical Requirements, rather than the Emuent Concentration Limits (ECL) listed in 10CFR20 Appendix B, Table 2,

]

Column 1.

I 2.

Liquid Releases The Emuent Concentration Limits of radioactive materials in liquid emuent is limited by 10CFR20, Appendix B, Table 2, Column 2.

6 J

River Bend Station 1997 Regulctory Guide 1.31 April 37,1998 C.

Measurements and Approximations of Total Radioactivity 1,

Gaseous Effluent a.

Fission and Activation Gases Periodic grab samples are obtained from the Main Plant Exhaust Duct, Fuel Building Exhaust Vent and Radwaste Building Exhaust Vent. These samples are analyzed utilizing high purity germanium detectors coupled to computerized pulse height analyzers. The sampling and analysis frequencies are described in Table 1.

Sampling and analysis of these effluent streams provide noble gas radionuclide relative abundance which can then be applied to the noble gas gross activity and gross activity release rate to obtain nuclide specific activities and release rates. The noble gas gross activity released within a specific time period is determined by integrating the stack monitor release rate over the considered time period. If no activity was detected between stack grab samples and l

a significant increase in hourly averages was recorded, the nuclide relative abundance of the last sami,le which indicated the presence of activity was utilized to obtain nuclide specific activities.

Correction factors for the monitors are derived and applied for each sampling period whenever noble gas radionuclides are detected in the effluent stream.

b.

Particulate and Iodines Particulates and iodines are continuously sampled from the three release points utilizing a particulate filter and charcoal cartridge in line with a sample pump (stack monitor pump). These filters and charcoal cartridges are removed and analyzed in accordance with the frequencies specified in Table 1. Analysis is performed to identify and quantify radionuclides utilizing high purity germanium detectors coupled to computerized pulse height analyzers. Given the nuclide specific activity concentrations, process flow rate, and time which the sample covered; the nuclide specific activity released to the environment can be obtained. Due to the continuous sampling process, it is assumed that the radioactive material is released to the environment at a constant rate within the sampling period. Sr-89 and Sr-90 are quantitatively analyzed by counting the digested filter precipitate with a gas flow proportional counter.

Gross alpha analysis is performed using a zine sulfide scintillation counter.

7

River Hend Static 1997 Regulatory ouide 1.31 Apr;l 27,1998 c.

Tritium i

Tritium grab samples are obtained from the three release points at the specified fiequencies listed in Table 1 utilizing an ice bath condensation collection method. The collected sample is then analyzed utilizing a Liquid Scintillation Counter. Given the tritium concentration, process flow rate, and time period for which the i

sample is obtained, the tritium activity released to the environment can be determined. Due to the frequency of sampling, it is assumed that the tritium is released to the environment at a constant rate within the time period for which the sample is obtained.

2.

Liquid Efiluent Representative grab samples are obtained from the appropriate sample j

recovery tank and analyzed prior to release of the tank in accordance with the frequencies listed in Table 2. Analysis for gamma emitting nuclides (including dissolved and entrained noble gases)is performed utilizing a high resolution germanium detector coupled to a computerized pulse height analyzer. Tritium concentration is determined utilizing a liquid scintillation counter. Sr-89 and Sr-90 are quantitatively analyzed by counting the precipitate with a gas flow proportional counter. Fe-55 is counted with a liquid scintillation counter after digestion of the iron. Gross alpha analysis is performed using a zinc sulfide scintillation counter.

I Given the nuclide specific activity concentration and total volume of the tank that was released, the activity of each nuclide released to the environment can be determined.

i i

D.

Batch Releases 1.

Liquid 1st and 2nd Quarter 1997

a. Number ofbatch releases 13
b. Total time period for batch releases 1540.06 hr
c. Maximum time period for batch releases 671.98 hr
d. Average time period for batch releases 118.47 hr
e. Minimum time period for a batch release 1.46 hr
f. Average stream flow during periods of release of effluent into a flowing stream ist Qtr 893,000 ft /sec 3

2nd Qtr:

895,000 ft'/sec 3rd and 4th Quarter 1997

a. Number of batch releases 120
b. Total time period for batch releases 601.17 hr 8

River Bend Statics 1997 Regulatory ouide 1.21 April 27,1998

c. Maximum time period for batch releases 10.50 hr
d. Average time period for batch releases 5.01 hr
e. Minimum time period for a batch release 3.88 hr
f. Average stream flow during periods of release of effluent into a flowing stream 3rd Qtr
353,000 ft'/sec 4th Qtr 265,000 ft'/sec 2.

Gaseous All gaseous releases from River Bend Station are considered continuous releases.

E.

Abnormal Releases No abnormal releases during the reporting period ofJanuary 1,1997 through December 31,1997.

F.

Estimate of Total Error 1.

Liquid The maximum error associated with sample collection, laboratory analysis, and discharge volume are collectively estimated to be:

Fission and Activation Products 1 14.2 %

Tritium 14.2 %

Dissolved and Entrained Noble Gases 1 14.2 %

Gross Alpha Radioactivity 1 14.2 %

2.

Gaseous The maximum errors (not including sample line loss) associated with sample flow, process flow, sample collection, monitor accuracy and laboratory analysis are collectively estimated to be:

Noble Gases 1 37.0%

Iodines 1 18.6 %

Particulate 18.6 %

Tritium i 18 2 %

3.

Determination ofTotal Error The total error (i.e., collective error due to sample collection, laboratory analysis, sample flow, process flow, monitor accuracy, etc.) is calculated using the following equation:

l 9

i

1 River Bend Station 1997 Reguictory ouid: 1.31 April 27,1998

\\/ ((Ei)' + (E )' +...(E.)')

Er

=

2 where:

Er total error

=

E,E...E.

individual errors due to sample collection, laboratory

=

i 2

analysis, sample flow, process flow, monitor accuracy, etc.

III.

GASEOUS EFFLUENT

SUMMARY

INFORMATION Refer to Tables 3,4 and 5 for " Summation of All Releases" and "Nuclides Released",

j respectively. It should be noted that an entry of"0.00E+00" Curie (Ci) or microcurie /second (uCi/sec) in this section indicates that the concentration of the particular radionuclide was below the Lower Limit of Detection (LLD) as listed in Table 1.

IV.

LIQUID EFFLUENT

SUMMARY

INFOM1ATION i

Refer to Table 6 for " Summation of All faleases and Nuclides Released" It should be noted that an entry of"0.00E+00" Ci or uCi/ml in this section indicates that the concentration of the particular radionuclide was below the Lower Limit of Detection (LLD) as listed in Table 2.

V.

SOLID WASTE Refer to Table 7, for " Solid Waste and Irradiated Fuel Shipments" VI.

RADIOLOGICAL IMPACT ON MAN The total body, skin, thyroid, and other organ doses to a member of the public from the uranium fuel cycle and direct radiation (40CFR190 compliance) calculated in accordance with the ODCM, was less than 25 mrem for the total body, skin and other organs; and less than 75 mrem for the thyroid.

Doses to the maximally exposed individual offsite were calculated using measured effluent data and annual average meteorological data. These doses can be found in Tables 8 through 10.

In addition, doses were calculated for a maximally exposed member of the public inside the site boundary. Parameters and assumptions utilized to make this determination can be found in Table 11. The results of the calculations can be found in Table 12. The maximally exposed member of the public on site was the private driver who delivers an employee to work and returns later that day to pick him/her up. It should be noted that liquid efiluent pathway dose was not considered since these individuals would not engage in activities that would allow exposure to this pathway.

10

Ri~ct iknd Statia 1997 Regulatory Guide 1.21 Apil 27,1998 VII.

METEOROLOGICAL DATA See Tables 13 and 14 for the cumulative joint frequency distributions and annual average data for continuous releases.

Vill. RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION OPERABILITY The minimum number of channels required to be OPERABLE as described in Table 3.3.11.2-1 of Technical Requirement 3.3.11.2 were, ifinoperable at any time in the period 1/1/97 through 12/31/97, restored to operable status within the required time. Reporting of these inoperable channels in this report is, therefore, not required.

IX.

RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION OPERABILITY The minimum number of channels required to be OPERABLE as described in Table 3.3.11.3-1 of Technical Requirement 3.3.11.3 were, ifinoperable at any time in the period 1/1/97 through 12/31/97, restored to operable status within the required time. Reporting of these inoperable channels in this report is therefore, not required.

X.

LIQUID IIOLD UP TANKS The maximum quantity of radioactive material, excluding tritium and dissolved or entrained noble gases, contained in any unprotected outdoor tank during the period of 1/1/97 through 12/31/97 was less than or equal to the 10 curie limit as required by Technical Specification 5.5.8.b.

XI.

RADIOLOGICAL ENVIRONMENTAL MONITORING There were no changes in radiological environmental monitoring locations during he reporting peiiod 1/1/97 through 12/31/97.

XII.

LAND USE CENSUS The Land Use Census, as required by Technical Requirement 4.12.2, did not identify any location (s) that would yield a calculated dose or dose commitment greater than the values calculated.

l XHL OFFSITE DOSE CALCULATION MANUAL (ODCM)

There were no revisions to the River Bend Station Offsite Dose Calculation Manual (ODCM) for the period 1/1/97 through 12/31/97.

l 11 l

1

(

River Bend Station 1997 Regulatory Guide 1.21 April 27,1998 XIV. MAJOR CIIANGES TO RADIOACTIVE LIQUID, GASEOUS AND SOLID 0

WASTE TREATMENT SYSTEMS J

There were no major cha. s to the radioactive liquid, gaseous, and solid waste treatment systems for the period of 1/1/97 through 12/31/97.

XV.

PROCESS CONTROL PROGRAM (PCP)

There were no changes to the Radwaste Process Control Program Station Procedure (RWS-0204) during the period of 1/1/97 through 12/31/97.

i 12

River Bend Station 1997 Regulatcy Guide 1.21 April 27,1998 TABLE 1 RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS PROGRAM Gaseous Release Sampling Minimum Type of Activity Lower Limit Type Frequency Analysis Analysis of Detection Frequency (LLD) uCi/ml A. Main Plant M

M Principal Gamma Exhaus: Duct Grab Sample Emitters 1.00E-04 H-3 1.00E-06 B. Fuel Buiiding M

M Principal Gamma Ventilation Grab Sample Emitters 1.00E-04 Exhaust Duct H-3 1.00E-06 C. Radwaste M

M Principal Gamma Building Grab Sample Emitters 1.00E-04 Ventilation Exhaust Duct

)

D. All Release Continuous W

I-131 1.00E-12 Types as listed Charcoal Sample in A, B, & C 1

above I-133 1.00E-10 Continuous W

Principal Gamma Particulate Emitters (I-131, 1.00E-Il Sample Others)

Continuous M

Gross Alpha Composite 1.00E-11 Particulate Sample Continuous Q

Sr-89, Sr-90 Composite 1.00E-11 Particulate Sample Continuous Noble Gas Noble Gases Monitor Gross Beta or 1.00E-06 Gamma W = At least once per 7 days M = At least once per 31 days Q = At least once per 92 days 13

River 13end S*.ation 1997 Regulatory Guide 1.21 April 27,1998 TABLE 2 RADIOACTIVE LIQUID WASTE SAMPLING AND ANALYSIS PROGRAM Liquid Release -

Sampling Minimum Type of Activity Lower Limit Type Frequency Analysis Analysis of Detection Frequency (LLD) uCi/mi A. Batch Waste P

P Principal Gamma 5.00E-07 Release (Liquid Each Batch Each Batch Emitters: except Radwaste for Ce-144 5.00E-06 Recovery Sample Tanks) j I-131 1.00E-06 P

M Dissolved and One Batch /M Entrained Gases 1.00E-05 (Gamma Emitters)

P M

H-3 1.00E-05 Each Batch Composite

{

Gross Alpha 1.00E-07 P

Q Sr-89, Sr-90 5.00E-08 Each Batch Composite Fe-55 1.00E-06 i

P = Prior to each radioactive release M = At least once per 31 days Q = At least once per 92 days 1

l 14

)

l Riter Bcnd Statia 1997 Regulatory Guide 1.21 April 27,1998 TABLE 3 Emuent and Waste Disposal Annual Report E Year Caseous Emuent - Sumn.ation of All Releases M Quarters j

Unit Quarter !

Quarter 2 Estimated Total Error %

A. Noble Oases

1. Total Release Ci 2.954E+01 6.436E+01 3.70E +01
2. Average release rate for period uCi/sec 3 80E+00 8.186 E+00
3. Percent of T.R. limrt (1) 6 898E-01 1.486E+00 B lodines
1. Total 1 131 and 1-123 I'I I Curies 2.848E-03 5.601 E-03 1.86E+01 1133 Curies 1.737E-02 2.559E-02 1.86E+01
2. Average release rate for period 1-131 3.66iE44 7.124 E-04 I-133 2.233 E-03 3 255E-03 3.1 131 + I 133 contribution percent of T.R.

1.497E+00 2.797E+00 l

limit i

C. Particulate

1. Particulate with half hves of > 8 days l

Ci 8.747E-04 9.770E44 1.86E+01

2. Average release rate for period uCi/sec 1.124E-04 1.243 E-04
3. Percent of T.R.imut 1.080E-01 1.140E-01
4. Gross alpha radioactivity Ci 0.00E+00 0.00E +00 D Tntium l

l

1. Total Release Ci 2.7%E+00 1.649E+00 1.82E+01
2. Average releue rate for penod g.vsec 3.478E41 2.097E 01
3. Percent of T.R. linut 4

7.500E-02 3 300E-02 (1) Either the gamma att dose linut of 5 mrads'qtr or beta air dose lunit of t o mrads/qtr(T.R. 3.11.2.2.a), which ever is most Imuting.

15

River Bend Static 1997 Regulatc7y Guide 1.21 April 27,1998 TABLE 3 Efiluent and Waste IMsposal Annual Report ],?91 Year

)

Gaseous Emuent - Sununetton of All Releases 2/3 Quarten Urut Quarter 3 Quarter 4 Estimated Total Error %

A. Noble Ga.ws l

1. Total Release Ci 1.203E+02 1.433E+01 3.70E+01
2. Average release rate for period uCi/sec 1.513E+01 1.803 E+00 i
3. Percent of T.R. limit (1) 2.852 E+00 3.399E-01 R lodmes
1. Total 1-131 and 1 133 I^I I Curies 1.506E-02 8.420E-04 1.86E+01 I'

)

Curies 1.044E 02 3.707E-03 1.86 E+0 I

2. Average release rate for period

{

j I-l 31 1.894E-03 1059E-04 uCL'sec I l33 1.313E 03 4.664E-04 3.1 131 + l-133 coritsibution percent of T.R.

6.650E+00 4 430E-01 limit j

i i

C. Particulate

1. Particulate with half hves of > 8 days l

Ci 4.073 E-03 4.729E-04 1.86E+01

2. Averagi sense rate for period uCPsec 5.123 E-04 5.949E-05
3. Percent of T.R.imut 1

l.080E41 7.200E-02

4. Gross alpha radioactivity Ci 0.00E+00 0.00E+00 D Tritium
1. Total Release Ci 1.700E+00 6.882E-01 1.82E+01

]

1 2 Average release rate for penod uCPsec 2.138E-01 8.657E-01 f

\\

l 3. Pumt of 'll lumt f

2.500E-02 1.700E-02 (1) Either the gamma air dose linut of 5 mraddytt or beta air dose imut of 10 mradiqtr (T.R 3.l l.2.2.a), which I

ever is most hmiting.

16

River Ben tion 1997 Regulatory Guide 1.21 April 27,1998 l

l TA%LE4 l

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT j._921 YEAR GASEOUS EFF1 UENT - CONDITIONALLY ELEVATED RELEASES Lq QUARTERS A. FISSION GASES Continuous Mode Batch Mode Nuclides Released Unit Quarter 1 Quarter 2 Quarter !

Quarter 2 Krypton-85M Ci 0.00E+00 5.34E-01 N/A N/A krypton-87 Ci 0.00E+00 5.93 E-03 N/A N/A krypton-88 Ci 0.00E+00 3.05E-01 N/A N/A Xenon-133M Ci 0.00E+00 1.22E-02 N/A N/A Xenon-133 Ci 1.82FA2 2.69E+00 N/A N/A Xenon-135M Ci 1.64E+01 1.36E+01 N/A N/A Xenon-135 Ci 4.24E+00 7.22E+00 N/A N/A Xenon-138 Ci 0.00E+00 2.07E-02 N/A N/A Total For Period Ci 2.06E+01 2.44E+01 N/A N/A B. IODINES Continuous Mode Batch Mode Nuclides Released Unit Quarter !

Quarter 2 Quarter !

Quarter 2 lodine-131 Ci 2.78E-03 5.51E-03 N/A N/A Iodine-133 Ci 1.72FA2 2.54E-02 N/A N/A Total For Period Ci 2.00E-02 3.09E42 N/A N/A C. PARTICULATES Continuous Mode Batch Mode Nuclides Released Unit Quarter 1 Quarter 2 Quarter !

Quarter 2 Manganese-54 Ci 5.80E 05 1.45E-04 N/A N/A Cobalt-58 Ci 7.17E 06 6.19E46 N/A N/A Cobalt-60 Ci 1.40E-05 2.72E 05 N/A N/A Niobiunw95 Ci 0.00E+00 2.12E 06 N/A N/A Strontiunw39 Ci 3.38E 04 3.29E-04 N/A N/A Strontium-90 Ci 7.75 E-07 4.76E-07 N/A N/A Rutheniund106 Ci 1.79E-05 0.00E+00 N/A N/A Silver 110m Ci 5.34E 06 7.89E-06 N/A N/A Ceriuncl41 Ci 2.42E-06 0 00E+00 N/A N/A Bariunpl40 Ci 4.13 E-04 3.86E 04 N/A N/A Total For Period Ci 8.57E-04 9.04E-04 N/A N/A D. TRITIUM Continuous Mode Batch Mode Nuclides Released Unit Quarter !

Quarter 2 Quarter !

Quarter 2 liydrogen-3 Ci 1.73 E+00 1.25E+00 N/A N/A Zeroes in this table indicate that no radwacmity waspresent at deseaabte levels. See Table ifor typicalMinimum Detectable Concentrations 17 1

l River Bend Station 1997 Regulatory Guide 1.21 April 27,1998 TAILE4 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT E YEAR GASEOUS EFFLUENT - CONDITIONALLY ELEVATED RELEASES 2,/f QUARTERS A. FISSION CASES Continuous Mode Batch Mode Nuclides Released Unit Quarter 3 Quarter 4 Quarter 3 Quarter 4 hsyptm87 Ci 5.64E-01 0.00E+00 N/A N/A Krypte88 Ci 7.53 E-01 0.00E+00 N/A N/A Xene133M Ci 2.16 E+00 0.00E+00 N/A N/A Xenon 133 Ci 4.04E+01 3.75 E+00 N/A N/A Xenon-135M Ci 7.22E+00 6.17E-01 N/A N/A Xenon-135 Ci 8.53E+00 1.16E+00 N/A N/A Total for Period Ci 5.97E+0!

5.53 E+00 N/A N/A B. lODINES Continuous Mode Batch Mode Nuclicka Released Unit Quarter 3 Quarter 4 Quaner 3 Quarter 4 lodine-131 Ci 1.50E-02 8.06E-04 N/A N/A lodme-133 Ci 1.03E 02 3.64E-03 N/A N/A Total For Period Ci 2.53 E-02 4.44E 03 N/A N/A C PARTICULATEa Continuous Mode Batch Mode Nuclides Released Urut Quarter 3 Quarter 4 Quarter 3 Quarter 4 Manganese-54 Ci 9.79E-06 8.22E45 N/A N/A fron-59 Ci 1.02E-05 4.52E-06 N/A N/A Cobalt-60 Ci 2.63E-05 1.23E-04 N/A N/A Zinc-65 Ci 4.36E-06 0.00e+00 N/A N/A Strontium-89 Ci 2.07E-04 7.53 E-05 N/A N/A Yttrium-91 Ci 3.58E-03 0.00E+00 N/A N/A Cesiundl37 Ci 3.28E-06 2.77E46 N/A N/A Banum-140 Ci 2.16E-04 9.01E-05 N/A N/A Total For Penod Ci 4 05E 03 3.78E-04 N/A N/A D TRITIUM Continuous Mode Batch Mode Nuclides Released Unit Quarter 3 Quarter 4 Quarter 3 Quarter 4 flydrogen-3 Ci 1.44E+00 4.77E-01 N/A N/A Zeroes in this table indicate that no radionaivity unspresent at derenable levels. See Table ifor OpicalMbumum Detectable Concentrations 18

Riwr Dend Station 1997 Regulatory Guide 1.2i April 27,1998 TABLEO EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT Jj!92 YEAR CASEOUS EFFLUENT - GROUND LEVEL Lq QUARTERS A. FISSION GASES Continuous Mode Batch Mode Nuclides Released Unit Quarter !

Quarter 2 Quarter 1 Quarter 2 Xenon-131M Ci 9.28E.03 0.000E+00 N/A N/A Xenon-133 Ci 3.95 E+00 1.75E+01 N/A N/A Xenon-135M Ci 2.70E-02 8.23E 01 N/A N/A Xenon-135 Ci 4.94E+00 2.16E+01 N/A N/A Total For Period Ci 8.93 E+00 4.00E+01 N/A N/A B. IODINES Continuous Mode Batch Mode Nuclides Released Unit Quarter 1 Quarter 2 Quarter !

Quarter 2 lodine 131 Ci 6.77E45 9.22E-05 N/A N/A lodine-133 Ci 1.52E-04 2.05 E-04 N/A N/A Total For Period Ci 2.19E-04 2.97E-04 N/A N/A C PARTICULATES Continuous Mode Batch Mode Nuclides Released Unit Quarter 1 Quarter 2 Quarter !

Quarter 2 Chrorniurn-51 Ci 6.73E47 0 00E+00 N/A N/A Manganese-54 Ci 1.41 E-05 5.42E 05 N/A N/A Cobalt-60 Ci 3.34E-06 1.88E-05 N/A N/A Strontiunw39 Ci 0.00E+00 1.42E-13 N/A N/A Total for Period Ci 1.81E 05 7.30E-05 N/A N/A D. TRITIUM Continuous Mode Batch Mode i

Nuclides Released Urut Quarter i Quarter 2 Quarter !

Quarter 2 Ilydrogen 3 Ci 9.80E 01 4.03 E-01 N/A N/A Zeroes in this table indicate that na radwactmty unspresent at detectable levels. See Table Ifor typical Afunknum Dnecamble Concentrations 1

\\

l 1

)

i I

19 l

River Bend Station 1997 Rrgulatory Guide 1.21 April 27,1998 l

TABLES i-l EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT M YEAR GASEOUS EFFLUENT - GROUND LEVEL }Li QUARTERS I'

A. FISSION CASES Continuous Mode Batch Mode Nuclides Released Unit Quarter 3 Quarter 4 Quarter 3 Quarter 4 Xenon-133 Ci 1.96E+01 3.25 E+00 N/A N/A Xenon-135M Ci 3.08E 01 3.47FAI N/A N/A Xenon 135 Ci 4.07E+01 5.20E+00 N/A N/A Total For Period Ci 6.06E+01 8.80E+00 N/A N/A B.10 DINES Continuous Mode Batch Mode Nuclides Released Unit Quarter 3 Quarter 4 Quarter 3 Quarter 4 1

i lodine-131 Ci 7.92E-05 3.58E-05 N/A N/A i

lodine 133 Ci 1.61E-04 7.00FA5 N/A N/A Total For Period Ci 2.40E-04 1.06E-04 N/A N/A C PARTICULATES Continuous Made Batch Mode Nuclides Released Urut Quarter 3 Quarter 4 Quarter!

Quarter 4 Manganese-54 Ci 1.04E-05 3.45E45 N/A N/A Cobalt-60 Ci 9 66E-06 6.00E 05 N/A N/A Stronti: m 89 Ci 2.84E-14 0.00E+00 N/A N/A Cesium-137 Ci 1.78E-07 0.00E+00 N/A N/A Total For Period Ci 2 02E 05 9.45E45 N/A N/A D. TRITIUM Continuous Made Batch Mode l

Nuclides Released Urut Quarter 3 Quarter 4 Quarter 3 Quarter 4 Ilydrogen-3 Ci 2.64FAI 2.12E 01 N/A N/A Zevent in this table inucate that no reboncsivity was present at detectable levels. See Table ifor 0picalMmunum Detectable Concanrarions 20

I River Bend Station 1997 Regulclory Guide 1.21 April 27,1998 TAllLE 6 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 VEAR LIQUID EFFLUENT - SUMMATI JN OF ALL RELFASES1G QUARTERS I

l Unit Quarter I Quarter 2 Est. Total Error %

l l

A. Fission and actisation products l 1. Total release (not including tritium, gases, alpha)

Ci 3.736E-03 4.798E-02 iA2+01

2. Average diluted concentration during period uCi'ml 2.85 IE-09 4.391 E-08 l 3. Percent of applicable limit (1) 6.000E-03 5.140E41 l

l

11. Tritium
1. Total release Ci 0.00E+00 8.597E-01 1.42E+01
2. Average diluted concentration during period uCi'ml 0.00E+00 7.866E-07
3. Percent of applicable limit (I) 0.00E+00 7.900E-02 C. Dissolved and entrained gases 1 Totalrelease Ci 0.00E+00 1.067E-02 1.42E+01
2. Average diluted concentration Juring period uCi'ml 0.00E+00 9.765 E-09 j
3. Percent of applicable limit (2) 0.00E +00 5.000E-03 1

D. Gross alpha radioactisity I

l 1 Totalrelease l

Ci 0.00E+00 0.00E+00 1.42E+01 j

Unit Quarter !

Quarter 2 Est. Total Error %

F. Volinne of weste released (prior to dilution)

Liters 8.371E+06 5.228E+0$

8.73 E-01 F. Volume of dilution water Liters 1.302E+09 1.092E+09 5.70 E-01 (1) 101FR20, Appendix D Table 2, Column 2.

(2) Tecimical Requircrment 3.11.1.1 limit of 2.00E-04 uCi'm! for dissolved or entrained noble gases in liquid effluent.

I 21

l i

River llend Station 1997 Reguictory Guide 1.21 April 27,1998 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 YEAR LIQUID EFFLUENT 1/2 QUARTERS TABLE 6 (CONTINt'ED)

A. Flasion & Activation Products Continuous N1 ode Hatch M ale Nuclides Released Unit Quarter !

Quarter 2 Quarter i Quarter 2 Silver Il0M Ci 0.00E+00 0 00E+00 0.00E+00 1.59E-05 Harium-140 Ci 0.00E+00 0.00E+00 0.00E+00 2.19E-05 Cerium-141 Ci 0.00E+00 0.00E+00 0.00E+00 1.12 E-04 Cobalt-58 Ci 0.00E+00 0.00E+00 0.00E+00 2.23E 03 Cobalt-60 Ci 0.00E+00 0.00E+00 0.00E+00 8.71 E-03 Chromium-51 Ci 0.00E+00 0.00E+00 0.00E+00 3.90E-03 Cesium 137 Ci 0.00E+00 0.00E +00 2.00E-06 0.00E+00 Iron-55 Ci 0.00E+00 0.00E+00 0.00E+00 4.39E-04 Iron-59 Ci 0.00E+00 0.00E+00 0.00E+00 8.06E 03 Iodine-131 Ci 0.00E+00 0.00E +00 0.00E+00 2.24E-04 lodine-133 Ci 0.00E+00 0.00E+00 0.00E+00 7.71 E 05

!.anthanum-140 Ci 0.00E400 0.00E+00 -

0.00E+00 7.03 E-03 Manganese-54 Ci 0.00E+00 0.00E+00 0.00E+00 1.40E-02 Molybdenum-99 Cs 0.00E+00 0.00E +00 2.26 E-05 4.03 E-05 Sodiu$-24 Ci 0.00E+00 0.00E+00 3 68E-03 1.56E-05 Niobium-95 Ci 0.00E+00 0.00E+00 0.00E400 2.83 E-04 Niobium-97 Ci 0.00E+00 0.00E+00 0.00E +00 3 25FA4 Neptunium-239 Ci 0.00E+00 0.00E+00 0.00E+00 4 99E-05 Ruthenium-103 Ci 0.00E+00 0.00E+00 0.00E+00 2.00E-04 Ruthenium-105 Ci 0.00E+00 0.00E+00 0.00E+00 2.19E-04 Antim$ny 122 Ci 0.00E+00 0.00E+00 0.00E+00 1.13 E-04 Antimony-124 Ci 0.00E+00 0.00E+00 0.00E+00 7.78 E-04 Antimony 125 Ci 0.00E400 0.00F <00 0.00E+00 2.79FA5 Tin-l l3 Ci 0.00E+00 0.00E+00 0.00E+00 2.54E-04 Strontium-89 Ci 0.00E+00 0.00E+00 0.00E+00 2.09E-05 Strontium-92 Ci 0.00E+00 0.00E+00 0.00E+00 1.54E-05 Technetium 99M Ci 0.00E+00 0.00E+00 3.02E-05 5.06E 05 Zine-65 Ci 0.00E+00 0.00E+00 0.00E+00 6.4 t E-04 Zirconium-95 Ci 0.00E+00 0.00E+00 0.00E+00 1.17E-04 TOTALS Ci 0.00E+00 0.00E+00 3.74E-03 4.80E-02 H.Trithun Continuous Mode Hatch Mode Nuclides Released Unit Quarter !

Quarter 2 Quarter i Quarter 2 liydrogen-3 Ci 0.00E400 0.00E400 0.00E+00 8.60E 01 22 m

River Bend Station 1997 Regulatory Guide 1,21 Artil 27,1998 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 YEAR LIQUID EFFLUENT 1/2 QUARTERS l

TAllLE 6 (CONTINUED) 1 C. INanched & Entrained Gem Continuous hinde htch Alode Nuclides Released Unit Quarter !

Quarter 2 Quarter 1 Quarter 2 Xenon-133 Ci 0.00E+00 0.00E4 00 0.00E+00 5.85 E-03 l

Xenon-133M Ci 0.00E+00 0.00E+00 0.00E+00 1.33 E-04 1

Xenon-135 Ci 0.00E+00 0.00 E+00 0.00E +00 4.69E-03 l

l TOTALS Ci 0.00E+00 0.00E+00 0.00E + 00 1.07E 02 l

Zeroes in this table indicate that no radsocctivity nos present at detecta&!e levels. See Table 2for typical Afinimum Detectable Concentrations D. Gross Alpha Activity Continuous %fode htch Niede Nuclides Released Unit Quarter 1 Quarter 2 Quarter !

Quarter 2 r

Total Release Ci N/A N/A 0.00E+00 0.00E+00 I

i l

f l

l

\\

23 m....

l 4

River Nd Station 1997 Regelatory Guide 1.21 April 27.1998 TABLE 6 EFFLUENT AND WASTE DISPOSAL, ANNUAL REPORT 1991 YEAR LIQUID EFFLUENT - SUMMATION OF All, RELEASESM QUARTERS

'l Umt Quaner 3 Quarter 4 Est. Total Ermr ?.

A. Finnlom and activation pioducts l 1. Total release (not including tritiunt gases, alpha)

Ci 2.753E-01 2.842E 02 1.42E+0!

2. Average diluted concentration during period uCi'ml 2.926E47 2.629E-08
3. Percent of applicable limit (1) to 3.504 E +00 2.590E41 w

i

11. Tritium I. Total release Ci 5.486E+00 1.635E400 1.42E+01
2. Average diluted concentration during period uCiml 5.830E 06 1.513E-06
3. Percent of applicable limit (1) 9 5.860E 01 1.52 = 91

)

C. Dissolved & Entrained Gases 1

1. Total release Ci 1.402E-01 2.235E42 1.42E+01
2. Avdage diluted concentration during period uCi'ml 1.490E-07 2.068E 08
3. Percent of applicable limit (2)

?.

7.500E 02 1.000E42 l). Grosa alpha radioactivity

1. Total release Ci 0.00E+00 0 00E &OO 1.42E+01 Unit Quader 3 Quarter 4 Est. Total Ermr %

E. Volume of waste released (prior to dilution) liters 4 966E+06 1.975E+06 8,73 E-01 F. Volume of dilution water l Liters 9.360E+08 1.079 E +09 5.70E-01 (I) 10CFR20, Appendix 11. Table 2, Column 2.

(3) Technical Requirement 3.11.1.1 limit of 2.00E44 uCi/ml for dissolved or entrained noble gases in liquid effluent.

24

1 River Bend Station 1997 Regulatory Guide 1.21 April 27,1993 EFFLUENT AND WASTE DI5POSAL ANNUAL REPORT 1997 YEAR LIQUID EFFLUENT 3/4 QUARTERS TABLE 6 (CONTIN!'ED)

A. Fission & Arth ation Products Continuous N1 ode flatch N1 ode Nuclides Released Unit Quaner 3 Quarter 4 Quarter 3 Quart (r 4 Silver Il0M Ci 0.00E+00 0.00E +00 6.51 E-04 6.76E-06 Barium 140 Ci 0.00E+00 0.00 E+00 1.28 E-04 0 00E+00 Ceriunel41 Ci 0.00E+00 0 00E+00 3.84E-04

1. l l E-04 Cerium-144 Ci 0.00E+00 0.00E 400 5.38E-04 0 00E+00 Cobalt 57 Ci 0.00E+00 0.00 E+ 00 1.32 E-05 0.00E+00 Cobalt-58 Ci 0.00E+00 0.00E+00 1.15 E-02 8.06E-04 l

Cobah-60 Ci 0.00E4 00 0.00E400 6.16E-02 5.60E-03 ChronuuneS t Ci 0.00E+00 0.00E + 00 1,74E-02 4.30E-03 Cesium-137 Ci 0.00E+00 0.00E +00 1.34E-05 1.40E-05 Iron-55 Ci 000E400 0 00F M 2.22E42 4.66E-03 Iron-59 Ci 0.00E+00 0.00E w 3.37E-02 2.05E-03 lodme-131 Ci 0.00E+00 0.00E+00 1.43 E-03 6.45E 05 lodme 133 Ci 0.00E+00 0.00E +00 1.22E 03 7.37E 05 lodine-135 Ci 0.00E+00 0 00E+00 6.10E-05 0.00E+00 1.anth um-140 Ci 0.00E+00 0.00 E +00 1.40 E-02 7.98E-04 Manganese-54 Ci 0.00E400 0.00 E +00 9.09 E-02 8.22E-03 Manganese-56 Ci 0.00E+00 0.00E+00 3.27E-0 5 0 00E+00 Molybdenum-99 Ci 0.00E-+ 00 0.00E+00 1.52 E-04 2.38 E-04 Sod um-24 Ci 0.00E+00 0.00E + 00 2 48FA5 0.00E+00 Niobium-95 Ci 0.00E+00 0.00E +00 1.13 E-03 5.49 E-05 Niobiunw97 Ci 0.00E400 0 00E400 4.02E-03 1.32E v 4 Nickel-65 Ci 0.00E+00 0.00E+00 5.94E-05 0 00E400 Neptuniunw239 Ci 0.00E+00 0.00E+00 2.26E-04 0.00E+00 Rhodiunwl05 Ci 0.00E+00 0.00E+00 1.27E-03 3.57E-05 Rutheniurn-103 Ci 0.00E+00 0.00E+00 3.99FA4 1.76E-05 Ruthenium-105 Ci 0.00E+00 0.00E

  • 00 1.10FA3 2.84 E-05 Antinu$ny-122 Ci 0.00E+00 0.00E+00 4 33E-04 4.75 E-05 Antimony-124 Ci 0.00E+00 0.00E400 3.82 E-03 2.82 E-04 Antimony 125 Ci 0.00E+00 0.00E400 108E-04 0.00E +00 Tin-l l)

Ci 0.00E+00 0.00 E4 00

1. 55 E-03 1.04E-04 StrontiunwS9 Ci 0.00E+00 0.00E+00 3.58 E-04 1.40E-04 i

Strontium-91 Ci 0.00E400 0.00E+ 00 2.49FA5 0.00E+ 00 I

Strontium-92 Ci 0.00E+00 0 00E+00 1.93 E-04 1.18 E-05 Technetium-99M Ci 0.00E400 0.00E4 00 7.22E-05 1.84E-04 Tungsten-IS7 Ci 0.00E+00 0.00E +00 1.67E-04 0.00E+00

(

25

[

River Hand Station 1997 Regulatory Guide 1.21 Apnl 27,1998 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 YEAR LIQUID EFFLUENT 3/4 QUARTERS TABLE 6(CONTINUED)

A. Plesies & Activation Proderts(contimmed)

Costineens Mode IIstch Mode Nuclides Released Urut Quarter 3 Quarter 4 Quarter 3 Quarter 4 Yttrium-92 Ci 0.00E+00 0.00E+00 4.39E44 0.00E+00 Zinc-65 Ci 0.00E+00 0.00E+00 3.74E 03 4.41E44 Zirconium-95 Ci 0.00E+00 0.00E+00 1.15E-04 0.00E+00 TOTALS Ci 0.00E+00 0.00E+00 2.75E41 2.84E 02 t

B. Trittene Contimeous Mode Batch Mode 3

Nuclides Released Urut Quarter 3 Quarter 4 Quarter 3 Quarter 4 Ilydrogen.3 Ci 0.00E+00 0.00E +00 5.49E+00 1.64E+00 C. DMed & Estrained Cases Coethneses Mode Beach Mode Nuctides Released Unit Quarter 3 Quarter 4 Quarter 3 Quarter 4 krypton-88 Ci 0.00E+00 0.00E+00 5.30E45 0.00E+00 Xenon 131M Ci 0.00E+00 0.00E+00 2.42E 04 0.00E+00 Xenon 133 Ci 0.00E+00 0.00E+00 6.78E 02 1.51E-02 Xenon 133M Ci 0.00E+00 0.00E+00 3.60E 03 7.81E-04 Xenon.135 Ci 0.00E+00 0.00E+00 6.85E 02 6.47E-03 TOTALS Ci 0.00E+00 0.00E+00 1.40E 01 2.24E-02 Zerear in nin enNe he6 cane nat ne en&enairny was prenant at unnea.sNe levels. See TnNe 2for typicalMinuousne D=*=~Al* Concesurnaions I'. Genes Alpha Activity Costimeous Mode Batch Mode s

Nuclides Released Unit Quarur 3 Quarter 4 Quarter 3 Quarter 4 Total Release Ci N/A N/A 0.00E+00 0.00E+00 26

River Bend Station 1997 Regulatory Guide 1.21 April 27,1998 TABL E 7 Effluent and Waste 1)isposal Annual Report 1997 Year Solid Waste and Irradiated Fuel Shipments Reporting Period 01/01/97 to 12/31/9,7 A. Solid Waste Shipped for Burial or Disposal (Not Irradiated Fuel) l

1. Type of Waste Units 12 Month Period Waste Class Estimated Error %

l Spent Resins, Filter m'

5.25E+01 A-U See Below

{

l Sludges, Evaporator Ci 1.91E+02 A-S j

l Bottoms, Etc.

1 Dry Compressible Wastes, m'

7.76E+00 A-U See Below Contaminated Equipment Ci 1.73E+00 A-S Etc.

l Irradiated Components m'

O.00E+00 N/A N/A l

Control Rods Ci 0.00E+00 j

l Etc.

j Other (None) m3 0.00E+00 N/A N/A Ci O.00E+00 Note: Volume considered to be the total disposal volume of the conta'ner.

l Radwaste Estimated Error %:

l Waste types considered are processed solid waste fi.e. resin, filter media) and non-compactible/compactible dry i

active waste.

(

l. Possible Errors a.

Volume b.

Representative Sampling c.

Instrument / Counting d.

Dose to Curie Calculations

2. Volume Error l

Level indication for processed resins can be determined to +/ 0.5 inches. This correlates to approximately i

1.0%. Container manufacturer stated design tolerance allows for 1.0% deviation from container dimensions. Volume error is not applicable to dry active waste.

3. Representative Sampling Error Sampling error for processed resins is based upon obtaining a representative sample from the waste being pcocessed using an iso-lock sampler. Sampling error from dry active waste is based upon obtaining a representative sample from the material being packaged. This error is estimated to be +/- 10% for all waste types, which is consistent with industry standards.
4. Instrument / Counting Error l

The error caused by sample geometry, counting time, sample activity and instrument background is l

estimated to be +/- 10%. The error for radiological survey instrumentation is estimated to be +/- 20%. This error is applicable to all waste types.

i

5. Dose to Curie Calculations Error The Dose to Curie method used to calculate activity suffers from analytical accuracy in that certain important parameters are neglected. These parameters are geometry of package, measuring instrument chr Neristics, build-up, internal attenuation effect, and external media attenuation. An activity correction facte.s applied to provide adjustment for these factors. This error is applicable to all waste types.

'!7

Rivw Bend Station 1997 Reguhory Guide 1.31 April 27,1998

2. Estimates of Major Nuclides by Waste Stream Spent Resins, Filter Studges, Dry Compressible Waste, Contaminated Equip., Etc.

Evaporator Bottoms, Etc.

Isotope Percent Abundance isotope Percent Abundance Co-60 3.79E+01 Fe-55 6.10E+01 Fe-55 5.72E+01 Co-60 2.63 +01 Mn 54 6.llE+00 Mn-54 8.37E+00 Sr-89 7.20E-01 Co-58 1.32E+00 Zn-65 1.26E+00 Ni-63 4.47E-01 Cs-137 -

8.21E-01 Cs-137 5.43E-01 Pu 241 3.00E-02 Cm-242 2.00E-03 Ni-63 6.49E C-14 4.99E-01 H-3 3.00E-02 Pu-241 1.80E-02 C-14 3.36E-01 Sr-90 1.06E-01 Sr-90 1.33E-01 St-89 1.56E+00 Cm 242 2.00E-03 Pu-238 1.00E-03 Determined by Measurement & Correlation.

Determined by Measurement & Correlation.

Packaged in Strong, Tight Liners.

Packaged in Strong, Tight Containers.

No Solidification Agent or Absorbent Used.

No Solidification Agent or Absorbent Used.

Irradiated Components. Control Rods. Etc.

Other None None

3.. Solid Waste Disposition Number of Shioments Mode of Tran3Dortation Destination 35 Truck Barnwell, SC B. Irradiated Fuel Shipments Disposition Number of Shioments Mode of Transportation Destination 0

N/A N/A 28 i

i

River Hend Station 1997 Rrgulatory Guide 1.21 April 27,1998 TABLE 8 Maximum Individual Doses Due to Noble Gas Releases 1997 l

Critical Sector Critical Distance Gamma Dose

  • Beta Dose *

(mrad)

(mrad) ist Quarter WNW 994m 2.13E-02 2.42E-02 And Quarter WNW 994m 7.43E-02 9.98E-02 3rd Quarter WNW 994m 1.22E-01 1.70E-01 4th Quarter WNW 994m 1.70E-02 2.27E-02 Annual Total WNW 994m 2.35E-01 3.17E-01 All age groups equally exposed f

29

River Dend Statim 1997 Regul: tory ouide 1.2 i April 27,1998 TABLE 9 Maximum Individual Doses Due To Gaseous Releases (113, Radiolodines and Particulates) 1997 Significant Organ Dose (mrem)

Critical Critical 8' Critical Critical Critical Sector Distance Age Group Organ Dose 1st Quarter WNW 994m Child Thyroid 1.18E-01 2nd Quarter WNW 994m Child Thyroid 2.13E-01 3rd Quarter WNW 994m Child Thyroid 5.01E-01 4th Quarter WNW 994m Child Thyroid 3.82E-02 Annual Total WNW 994m Child Thyroid 8.71E-01

  • The 994m maximum individual includes a hypothetical "contml cow" at 4.5 miles in the WNW sector 30

River llend Static 1997 Regulatory Guide 1.21 Apil 27,1998 TABLE 10 Maximum Individual Doses (Liquid) 1997 Critical Receptor: Edge of Initial Mixing Zone Total Body Dose (mrem)

Significant Organ Dose (mrem)

Critical Dose Critical Critical Dose Age Age Organ 1st Quarter Adult 2.85B-05 Adult Liver

  • 3.34E-05 2nd Quarter Adult 8.21E-04 Adult GI Tract 1.27E-02 3rd Quarter Adult 1.67E-02 Adult GI Tract 2.53E-01 4th Quarter Adult 5.39E-04 Adult GI Tract 7.72E-03 Annual Total Adult 1.81E-02 Adult GI Tract 2.73E-01
  • The GI Tract was the critical organ for the year. The dose to the GI Tract during ist Quarter was 1.95 E-05.

31

River Bend Stdica 1997 RegulcJcy Guide 1.21 Apil 27,1998 TABLE 11 ASSUMPTIONS / PARAMETERS FOR DOSES TO A MEMBER OF TiiE PUBLIC INSIDE SITE BOUNDARY MEMBER OF LOCATION DISTANCE")

SECTOR DURATION THE PUBLIC METERS (IIR/ YEAR)

Private Drivers North Parking 275 N

1.25E+02*

Lot Lawn Service General Services 115

  • ENE 5.20E+02 Provider Building People Entering Site Without Alligator Bayou 2500 SW 4.00E+01 Consent Casual Drivers Main Admin.

500 WNW 7.60E+01")

Building (1) The approximate distance from main plant vent exhaust to location.

(2) Lawn Service Provider works around the General Services Building lawn eight hours per day, 5 days per week,13 weeks per year.

(3) An individual is assumed to be on site 0.25/hr in the morning and 0.25/hr in the evening, 5 days per week, 50 weeks per year.

a (4) An individual is assumed to be on site 0.5 tu/ day.

(5) Liquid pathways dose is not considered due to the nature of activities that individuals are engaged in.

32 l

I River ikmd Station 1997 Regulatory cuide 1.21 April 27.1998 TABLE 12 DOSES TO MEMBERS OF TIIE PUBLIC ON SITE FROM GASEOUS RELEASES 1997 MEMBER RECEPTOR QUARTER CRITICAL CRITICAL CRITICAL TOTAL OF Tile AGE ORGAN ORGAN BODY LOCATION PUBLIC GROUP DOSE DOSE (MREM)

(MREM)

Private North 1st Adult Thyroid 1.97E-03 1.35E-03 Drivers Parking Quarter Lot at 275 m N 2nd Adult Thyroid 5.16E-03 4.12E-03 Quarter 3rd Adult Thyroid 8.23E-03 6.60E-03 Quarter 4th Adult Thyroid 1.39E-03 1.21 E-03 Quarter Annual Adult Thyroid 1.67E-02

.33E-02 Total j'

t S rvice Services Ist Adult Thyroid 4.10E-04 2.98E-04 r i Building Quarter 115m ENE 2nd Adult Thyroid 1.17E-03 9.89E-04 Quarter 3rd Adult Thyroid 1.91 E-03 1.62E-03 Quarter 4th Adult Thyroid 2.89E-04 2.56E-04 Quarter Annual Adult Thyroid 3.78E-03 3.17E-03 Total 33 I

J

River Dend St: tion 1997 Regul: tory Guide 1.21 April 27,1998 TABLE 12 DOSES TO MEMBERS OF Tile PUBLiC ON SITE FROM GASEOUS RELEASES 1997 MEMBER RECEPTOR QUARTER CRITICAL CRITICAL CRITICAL TOTAL OF TIIE LOCATION AGE ORGAN ORGAN BODY PUBLIC GROUP DOSE DOSE (MREM)

(MREM)

People Alligator 1st Adult Thyroid 1.52 E-05 9.94E-06 Entering Bayou at Quarter Site 2500 m SW Without Consent t

2nd Adult Thyroid 3.71E-05 2.83 E-05 Quarter 3rd Adult Thyroid 5.91 E-05 4.50E-05 Quarter 4th Adult Thyroid 8.88E-06 7.43E-06 Quarter Annual Adult Thyroid 1.20E-04 9.07E-05 Total Casual Main 1st Adult Thyroid 7.07E-04 4.75E-04 Driver Admin. at Quarter 500 m WNW 2nd Adult Thyroid 1.80E-03 1.41E-03 Quarter 3rd Adult Thyroid 2.87E-03 2.25E-03 Quarter 4th Adult Thyroid 4.66E-04 4.01E-04 Quarter Annual Adult Thyroid 5.84E-03 4.54E-03 Total 34

Rim llend Station 1997 Regulatory Guide 1.31 April 27,1998 Table 13 Meteorological Data - Joint Frequency Tables

  1. d w

35

River Bend Station 1997 Regubory Guide 1.21 April 27.1998 i

RIVER BEND STATION JOINT FREQUENCY 7ABLE ALL STABILITT CLASSES FROM 1/ 1/97 0:00 TO 3/31/97 23:00 PRIMARY SENSCAS 30 FOOT WIND SPEED (METERS /SECOW9)

WIND.22.51

.76-1.1 1.6 2.1-3.1-5.1 7.1-10.1-13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

3 1

8 20 33 58 58 0

0 0

0 0 181 NNE 3

5 10 16 37 77 31 0

0 0

0 0 179 NE 4

6 7 10 25 93 19 0

0 0

0 0 164 l

ENE 7 14 13 17 10 28 41 10 0

0 0

0 140 l

E 8 11 4

7 8

5 1

0 0

0 0

0 44 l

ESE 3

8 13 19 21 36 4

0 0

0 0

0 104 i

SE 0

5 4 32 50 75 33 0

0 0

0 0 199

$$E 1

1 1

12 9 33 67 11 0

0 0

0 135 S

0 2

4 14 24 49 59 11 1

0 0

0 164 SSW 0

1 1

18 33 34 47 3

0 0

0 0 137 SW 2

1 5

17 6 27 23 0

0 0

0 0 81 i

WSW 1

4 12 11 16 24 11 0

0 0

0 0 79 W

4 10 4

13 12 18 5

0 0

0 0

0 66 WNW 4

6 3

7 14 20 16 0

0 0

0 0 70 NW 1

15 12 12 13 21 3

0 0

0 0

0 77 NNW 2

6 7 13 18 47 34 7

0 0

0 0 134 TOTAL 43 96 108 238 329 645 452 42 1

0 0

0 1954 NUMBER OF CALMS:

3 NUM8ER OF INVALID HOUR $: 203 NUMBER OF VALID HOURS: 1957 TOTAL HOURS FOR THE PERIOD: 2160

)

RIVER BEND STATION JOINT FREQUENCY TABLE ST3BILITY CLASS A FROM 1/ 1/97 0:00 TO 3/31/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1 1.6 2.1 3.1-5.1-7.1-10.1 13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 O

O O

0 3

5 0

0 0

0 0

8 I

NNE 0

0 0

0 0 10 7

0 0

0 0

0 17 NE O

O O

O 1

16 10 0

0 0

0 0 27 ENE 0

0 0

0 0

8 1

0 0

0 0

0 9

E 0

0 0

0 2

1 0

0 0

0 0

0 3

i ESE 0

0 0

1 1

5 1

0 0

0 0

0 8

j SE O

O 0

0 1

6 8

0 0

0 0

0 15 SSE 0

0 0

0 0

5 9

1 0

0 0

0 15 S

0 0

0 0

0 0

9 0

0 0

0 0

9

$$W 0

0 0

0 0

2 4

0 0

0 0

0 6

SW 0

0 0

0 1

1 2

0 0

0 0

0 4

WSW 0

0 0

0 1

8 2

0 0

0 0

0 11 W

0 0

0 0

0 2

0 0

0 0

0 0

2 WWW 0

0 0

0 1

0 0

0 0

0 0

0 1

NW 0

0 0

0 0

0 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

1 0

0 0

0 1

TCTAL 0 0

0 1

8 67 58 2

0 0

0 0 136 NUM8ER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUM8ER OF VALID HOURS:

136 TOTAL HOURS FOR THE PERIOD:

136 36

River Bend Station 1997 Regulatory Guide 121 April 27.1998 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS B

~ ROM 1/ 1/97 0:00 TO 3/31/97 23:00 PRIMARY SENSORS - 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-.1.1 1.6 2.1-3.1-5.1 7.1 10.1-13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

O 0

0 0

0 3

5 0

0 0

0 0

8 NNE 0

0 0

0 3

9 3

0 0

0 0

0 15 NF 0

0 0

0 0

7 2

0 0

0 0

0 9

ENE O

O O

O O

4 1

0 0

0 0

0 5

E O

O O

O O

0 0

0 0

0 0

0 0

ESE O

O O

O 1

2 1

0 0

0 0

0 4

SE 0

0 0

0 3

8 3

0 0

0 0

0 14 SSE 0

0 0.

0 0

2 4

4 0

0 0

0 10 S

0 0

0 0

0 1

13 3

0 0

0 0 17 SSW 0

0 0

0 4

5 10 0

0 0

0 0 19 SW 0

0 0

0 0

5 8

0 0

0 0

0 13 WSW 0

0 0

1 3 11 6

0 0

0 0

0 21 W

0 0

0 0

2 7

3 0

0 0

0 0 12 WNW 0

0 0

0 0

0 0

0 0

0 0

0 0

NW 0

0 1

0 0

1 0

0 0

0 9

0 2

NNW 0

0 0

0 0

1 2

3 0

0 0

0 6

TOTAL 0 0

1 1

16 66 61 10 0

0 0

0 155 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

155 TOTAL HOURS FOR THE PERIOD:

155 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS C FROM 1/ 1/97 0:00 TO 3/31/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1 1.6-2.1-3.1-5.1 7.1 10.1 13.1 >18 To.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 0

0 3

6 0

0 0

0 0

9 NNE O

0 0

0 1

2 0

0 0

0 0

0 3

NE 0

0 0

0 0

0 0

0 0

0 0

0 0

ENE 0

0 0

0 0

3 2

1 0

0 0

0 6

E 0

0 0

0 0

0 0

0 0

0 0

0 0

ESE 0

0 0

1 1

0 0

0 0

0 0

0 2

SE 0

0 0

0 2

1 1

0 0

0 0

0 4

SSE O

O O

O O

3 2

0 0

0 0

0 5

S 0

0 0

0 0

1 5

2 0

0 0

0 8

SSW 0

0 0

0 2

1 2

0 0

0 0

0 SW 0

0 0

0 0

4 2

0 0

0 0

0 6

WSW 0

0 0

0 5

2 0

0 0

0 0

0 7

W 0

0 0

0 2

5 0

0 0

0 0

0 7

WNW 0

0 0

0 1

3 0

0 0

0 0

0 4

NW 0

0 0

2 1

0 0

0 0

0 0

0 3

NNW 0

0 0

0 0

1 4

0 0

0 0

.....................................................'O...................

TOTAL 0 0

0 3

15 29 24 3

0 0

0 0 74 NUMBER OF CALMS:

0 NUMBER OF INb4 LID HOURS:

0 NUMBER OF VALID HOUR $:

74 TOTAL HOURS FOR T' E PERIOD:

74 A

37

a River Bend Static 1997 Regulatory Guide 1.21 April;7,1998 RIVER BEND S?ATICJ J0lNT FREQUENCY TABLE STABILITY CLASS 0 FROM 1/ 1/97 0:00 To 3/31/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERt/SECOND)

WIND.22.51

.76-1.1-1.6 2.1-3.1-5.1-7.1 10.1 13.1- >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 O

3 8 23 46 39 0

0 0

0 0 119 NNE O

1 0

7 24 46 20 0

0 0

0 0 98 NE O

1 1

0 6 61 7

0 0

0 0

0 76 I

ENE O

1 1

6 4 11 36 9

0 0

0 0 68 E

O 0

0 3

2 1

1 0

0 0

0 0

7 j

ESE O

O 0

3 7 22 2

0 0

0 0

0 34 i

SE 0

1 2

6 23 33 20 0

0 0

0 0 85 SSE O

O 0

2 5 20 52 6

0 0

0 0 85 S

0 0

1 4

9 40 30 6

1 0

0 0 91 SSW 0

0 0

8 15 16 29 3

0 0

0 0 71 SW 0

0 2

8 5 13 to 0

0 0

0 0 38 WSW 0

0 2

7 7

3 3

0 0

0 0

0 22 W

0 1

1 9

8 4

2 0

0 0

0 0 25 WNW 0

1 1

3 11 13 16 0

0 0

0 0 45 NW 0

0 3

4 10 18 3

0 0

0 0

0 38 NNW 0

0 4

4 12 40 27 3

0 0

0 0 90 TOTAL 0 6 21 82 171 387 297 27 1

0 0

0 992 NUMBER OF CALMS:

2 NUMBER OF INVALIO HOURS:

40 NUMBER OF VALID HOUR $:

994 TOTAL HOURS FOR THE PERIOD: 1034 RIVER BEhD STATION j

JOINT FREQJENCY TA8LE l

STABILITY CLASS E FROM 1/ 1/97 0:00 TO 3/31/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WINO.22.51

.76-1.1 1.6 2.1 3.1-5.1 7.1 10.1 13.1 >18 TOT.

{

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

1 0

4 12 10 3

3 0

0 0

0 0 33 HNE 0

1 5

5 9 10 1

0 0

0 0

0 31 NE 1

1 3

5 15 7

0 0

0 0

0 0 32 ENE 1

1 3

3 3

1 1

0 0

0 0

0 13 E

O 1

2 2

4 3

0 0

0 0

0 0 12 ESE 2

3 6

6 11 7

0 0

0 0

0 0 35 SE O

1 0 20 18 26 1

0 0

0 0

0 66 SSE O

O 1

6 2

3 0

0 0

0 0

0 12 S

0 1

1 9 14 7

2 0

0 0

0 0 34 SSW 0

1 0

6 11 10 2

'0 0

0 0

0 30 SW 0

0 2

3 0

4 1

0 0

0 0

0 10 WSW 0

1 4

1 0

0 0

0 0

0 0

0 6

W 0

1 1

2 0

0 0

0 0

0 0

0 4

WNW 0

1 1

4 1

4 0

0 0

0 0

0 11 NW 0

6 0

2 2

2 0

0 0

0 0

0 12 NNW 0

2 0

6 6

5 1

0 0

0 0

0 20 TOTAL 5 21 33 92 106 92 12 0

0 0

0 0 361 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALIO HOUR $:

361 TOTAL HOURS FOR THE PERIOD:

361 38

River Hend Station 1997 Regulctory Guide 1.21 April 37,1998 RWER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS F FROM 1/ 1/97 0:00 TO 0/31/97 23:00 PRIMARY SENSORS - 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1 1.6-2.1 3.1 5.1 7.1-10.1 13.1 >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

1 0

1 0

0 0

0 0

0 0

0 0

2 NNE 1

0 3

3 0

0 0

0 0

0 0

0 7

NE 0

2 1

5 3

2 0

0 0

0 0

0 13 EhE 1

0 0

2 3

1 0

0 0

0 0

0 7

E 2

2 0

2 0

0 0

0 0

0 0

0 6

ESE 1

3 5

6 0

0 0

0 0

0 0

0 15 SE O

2 1

5 3

1 0

0 0

0 0

0 12 SSE 1

0 0

3 2

0 0

0 0

0 0

0 6

S 0

1 2

1 1

0 0

0 0

0 0

0 5

SSW 0

0 0

4 1

0 0

0 0

0 0

0 5

SW 1

0 0

6 0

0 0

0 0

0 0

0 7

WSW 0

1 5

2 0

0 0

0 0

0 0

0 8

W 2

2 1

2 0

0 0

0 0

0 0

0 7

WW 1

2 1

0 0

0 0

0 0

0 0

0 4

NW 0

4 4

3 0

0 0

0 0

0 0

0 11 NNW 0

2 0

3 0

0 0

0 0

0 0

0 5

TOTAL 11 21 24 47 13 4

0 0

0 0

0 0 120 NUM8ER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

120 TOTAL HOURS FDR THE PERIOD:

120 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS 0 FROM 1/ 1/97 0:00 TO 3/31/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1-1.6 2.1 3.1 5.1-7.1-10.1-13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

1 1

0 0

0 0

0 0

0 0

0 0

2 NNE 2

3 2

1 0

0 0

0 0

0 0

0 8

NE 3

2 2

0 0

0 0

0 0

0 0

0 7

ENE 5

12 9

6 0

0 0

0 0

0 0

0 32 E

6 8

2 0

0 0

0 0

0 0

0 0 16 ESE O

2 2

2 0

0 0

0 0

0 0

0 6

SE 0

1 1

1 0

0 0

0 0

0 0

0 3

SSE O

1 0

1 0

0 0

0 0

0 0

0 2

S 0

0 0

0 0

0 0

0 0

0 0

0 0

SSW 0

0 1

0 0

0 0

0 0

0 0

0 1

SW 1

1 1

0 0

0 0

0 0

0 0

0 3

WSW 1

2 1

0 0

0 0

0 0

0 0

0 4

W 2

6 1

0 0

0 0

0 0

0 0

0 9

WW 3

2 0

0 0

0 0

0 0

0 0

0 5

NW 1

5 4

1 C

0 0

0 0

0 0

0 11 NNW 2

2 3

0 0

0 0

0 0

0 0

0 7

TOTAL 27 48 29 12 0

0 0

0 0

0 0

0 116 NUM8ER OF CALMS:

1 NUM8ER OF INVALID HOURS:

0 NUMBER OF VALID HOURS: 117 TOTAL HOURS FOR THE PERIOD:

117 39

)

I l

River Bend Station 1997 R gulatcy Guide 1.21 April 27.1998 RIVER 8END STATION JOINT FREQUENCY TABLE ALL STABILITY CLASSES i

FROM 1/ 1/97 0:00 TO 3/31/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1-1.6-2.1-3.1 5.1-7.1-10.1-13.1 >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.J 7.0 10.0 13.0 18.0

)

N 1

0 1

3 6 35 95 27 0

0 0

0 168 NNE 0

1 6

5 82 99 16 0

0 0

0 209 NE 0

0 3

2 22 121 29 3

0 0

0 181 ENE O

O 1

3 1

8 62 54 11 4

0 0 144 E

0 1

0 3

7 11 10 2

0 2

0 0 36 ESE 0

0 0

4 3

14 86 56 6

0 0

0 169 l

SE O

0 1

1 6 18 77 45 2

0 0

0 151 SSE 0

0 0

3 8 18 65 31 11 0

0 0 136 S

0 0

0 4 12 25 78 25 7

0 0

0 151 SSW 0

0 1

3 4 30 68 28 1

0 0

0 135 SW 0

0 1

1 7 35 48 16 0

0 0

0 108 WSW 0

0 0

4 7 42 27 13 2

0 0

0 95 W

0 1

0 5

12 26 22 5

0 0

0 0 71 WNW 0

1 0

5 5 26 23 13 0

0 0

0 73 NW 0

0 0

4 3 16 23 2

1 0

0 0 49 NNW 0

0 3

3 3 26 65 16 5

0 0

0 121 q

TOTAL 1

4 9 55 91 434 969 379 49 6

0 0 1997 j

NUM8ER OF CALMS:

0

)

NUM8ER OF INVALID HOUR $:

163 NUM8ER OF VALID HOURS: 1997 TOTAL HOURS FOR THE PERIOD: 2160 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS A FROM 1/ 1/97 0:00 TO 3/31/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

WINO.22.51

.76-1.1 1.6-2.1-3.1-5.1 7.1 10.1 13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

O 0

0 0

0 0

3 4

0 0

0 0

7 NNE O

O O

O O

6 6

2 0

0 0

0 14 NE O

0 0

0 0

3 15 8

1 0

0 0 27 ENE O

O O

0 0

0 11 4

0 0

0 0 15 E

O O

0 0

0 1

0 0

0 0

0 0

1 ESE O

0 0

1 0

1 9

4 1

0 0

0 16 SE O

O O

O 1

1 1

8 0

0 0

0 11 SSE O

0 0

0 0

1 8

2 1

0 0

0 12 S

0 0

0 0

0 0

6 1

0 0

0 0

7 SSW 0

0 0

0 0

1 2

4 0

0 0

0 7

SW 0

0 0

0 0

1 1

1 0

0 0

0 3

WSW 0

0 0

0 0

1 9

1 0

0 0

0 11 W

0 0

0 0

0 1

2 0

0 0

0 0

3 WW 0

0 0

0 0

1 0

0 0

0 0

0 1

NW 0

0 0

0 0

0 0

0 0

0 0

0 0

NNW D

0 0

0 0

0 0

1 0

0 0

0 1

TOTAL 0 0

0 1

1 18 73 40 3

0 0

0 136 NUMBER OF CALMS:

0 MUMBER OF INVALID HOURS:

0 NUW8ER OF VALID HOURS:

136 TOTAL HOURS FDR THE PERIOD:

136 40

Riwr Ihmd Station 1997 Regulatory Guide 1.21 April 31.1998 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS 8 FROM 1/ 1/97 0:00 TO 3/31/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

{

WIND.22.51

.76-1.1 1.6 2.1-3.1-5.1-7.1-10.1-13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 i

N 0

0 0

0 0

1 7

2 0

0 0

0 10 NNE O

O 0

0 0

7 2

2 0

0 0

0 11 NE O

O O

0 0

4 4

2 0

0 0

0 10 ENE O

0 0

0 0

1 4

2 0

0 0

0 7

1 E

O O

0 0

0 0

1 0

0 0

0 0

1 ESE 0

0 0

0 2

1 5

0 1

0 0

0 9

SE 0

0 0

0 0

2 3

3 0

0 0

0 8

j SSE O

0 0

0 0

2 5

3 3

0 0

0 13 S

0 0

0 0

0 0 11 3

2 0

0 0 16 SSW 0

0 0

0 0

6 7

2 0

0 0

0 15 SW 0

0 0

0 0

3 3

6 0

0 0

0 12 WSW 0

0 0

1 0

8 8

4 2

0 0

0 23 W

0 0

0 0

1 2

9 1

0 0

0 0 13 WNW 0

0 0

0 0

1 0

0 0

0 0

0 1

NW 0

0 0

1 0

0 0

0 0

0 0

0 f

NNW 0

0 0

0 0

0 2

1 2

0 0

0 5

l TOTAL 0 0

0 2

3 38 71 31 10 0

0 0 155 1

NUM8ER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUM8ER OF VALID HOURS:

155 TOTAL HOURS FOR THE PERIOD:

155 i

RIVER BEND STATION i

J0!NT FREQUENCY TABLE STABILITY CLASS C FROM 1/ 1/97 0:00 To 3/31/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

{

WIND.22.51.76 1.1-1.6-2.*

3.1 5.1 7.1 10.1 13.1 >18 TOT.

l DIR

.50.75 1.0 1.5 2.0 3.t' 5.0 7.0 10.0 13.0 18.0 l

l i

N 0

0 0

0 0

0 6

1 0

0 0

0 7

NNE O

0 0

0 0

3 2

0 U

0 0

0 NE O

0 0

0 0

0 0

0 0

0 0

0 0

l ENE O

O O

0 0

0 3

2 1

0 0

0 6

E 0

0 0

0 0

0 0

0 0

0 0

0 0

(

ESE O

O O

1 0

3 1

0 0

0 0

0 5

SE 9

0 0

0 0

0 1

1 0

0 0

0 2

SSE L

0 0

0 1'

1 3

1 1

0 0

0 7

S 0

0 0

0 0

1 4

0 1

0 0

0 6

SSW 0

0 0

0 0

1 0

3 0

0 0

0 4

SW 0

0 0

0 0

3 3

1 0

0 0

0 7

WSW 0

0 0

0 2

2 2

0 0

0 0

0 6

W 0

0 0

1 0

4 3

0 0

0 0

0 8

WNW 0

0 0

0 0

2 2

0 0

0 0

0 4

NW 0

0 0

0 1

1 0

0 0

0 0

0 2

NNW 0

0 0

0 0

1 4

0 0

0 0

0 5

TOTAL 0 0

0 2

4 22 34 9

3 0

0 0 74 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

74 total N(tlR$ FOR TNE pia 100:

74 41

i I

River Ikul Station 1997 Regulatory Guide 1.21 April 37.1998 RIVER BEND STATION JOINT FREQUENCY TABLE l

STABILITY CLASS 0 1

FROM 1/ 1/97 0:00 TO 3/31/97 23:00 l

PRIMARY SENSORS 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1-1.6-2.1-3.1-5.1 7.1-10.1 13.1- >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 3

4 22 62 18 0

0 0

0 109 NNE O

0 0

4 4 51 74 11 0

0 0

0 144 NE O

0 0

2 0

4 54 18 2

0 0

0 80 ENE 0

0 0

1 1

1 22 37 10 4

0 0 76 E

0 0

0 2

1 1

5 0

0 2

0 0 11 ESE O

O 0

0 1

1 28 30 2

0 0

0 62 SE 0

0 0

0 2

5 23 25 2

0 0

0 57 SSE 0

0 0

2 2

8 39 25 6

0 0

0 82 l

S 0

0 0

2 8 10 41 21 4

0 0

0 86 SSW 0

0 0

1 1

10 32 16 1

0 0

0 61 SW 0

0 0

0 3

13 24 8

0 0

0 0 48 WSW 0

0 0

2 4 16 3

7 0

0 0

0 32 W

0 0

0 0

5 13 8

4 0

0 0

0 30 WNW 0

0 0

2 4

8 14 13 0

0 0

0 41 NW 0

0 0

2 2 12 17 2

1 0

0 0 36 NNW 0

0 2

2 0 15 44 13 3

0 0

0 79 TOTAL 0 0

2 25 42 190 490 248 31 6

0 0 1034 NUMSER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOUR $r 1034 TOTAL HOURS FOR THE PERIOD: 1034 i

RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS E FROM 1/ 1/97 0:00 TO 3/31/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1 1.6-2.1 3.1 5.1-7.1 10.1-13.1- >18 TOT.

D!R

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

1 0

1 0

1 8 14 2

0 0

0 0 27 NNE 0

0 0

0 0 13 15 1

0 0

0 0 29 NE O

1 0

0 1

7 33 0

0 0

0 0 42 ENE O

O 0

1 0

3 11 3

0 0

0 0 18 E

O 1

0 0

3 2

2 2

0 0

0 0 10 ESE O

0 0

1 0

2 29 19 2

0 0

0 $3 SE 0

0 1

0 1

4 31 8

0 0

0 0 45 SSE O

0 0

1 3

5 5

0 0

0 0

0 14 S

0 0

0 0

1 11 13 0

0 0

0 0 25 SSW 0

0 0

0 2

9 23 3

0 0

0 0 37

)

i SW 0

0 1

0 1

2 9

0 0

0 0

0 13 WSW 0

0 0

0 1

6 0

1 0

0 0

0 8

W 0

0 0

2 2

1 0

0 0

0 0

0 5

WWW 0

0 0

2 1

6 5

0 0

0 0

0 14 NW 0

0 0

0 0

0 2

0 0

0 0

0 2

NNW 0

0 1

1 1

4 11 1

0 0

0 0 19 TOTAL 1

2 4

8 18 83 203 40 2

0 0

0 361 NUPSER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

361 TOTAL HOURS FOR THE PER100:

361 I

42

1 River Iknd Station 1997 Rigulatory Ouide 1.21 April 27.1998 RIVER BEND STATION JotNT FREQUENCY TABLE STA81LITY CLASS F FROM 1/ 1/97 0:00 To 3/31/97 23:00 PRIMARY SENSORS 150 FOOT I

WIND SPEED (METERS /SECONO)

WINO.22.51

.76-1.1 1.6 2.1-3.1 5.1 7.1 10.1 13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

O O

O O

O 3

2 0

0 0

0 0

5 NNE 0

0 0

1 0

1 0

0 0

0 0

0 2

NE O

0 0

0 0

2 8

1 0

0 0

0 11 ENE O

O O

1 0

0 9

5 0

0 0

0 15 j

E O

O C

0 1

1 2

0 0

0 0

0 4

ESE O

0 0

0 0

1 11 3

0 0

0 0 15 i

SE O

O 0

0 2

4 8

1 0

0 0

0 15 SSE 0

0 0

0 2

1 3

0 0

0 0

0 6

S 0

0 0

1 3

2 1

0 0

0 0

0 7

SSW 0

0 0

0 0

1 4

0 0

0 0

0 5

SW 0

0 0

1 0

7 6

0 0

0 0

0 14 WSW 0

0 0

0 0

2 4

0 0

0 0

0 6

W 0-0 0

1 1

3 0

0 0

0 0

0 5

WNW 0

0 0

1 0

1 1

0 0

0 0

0 3

NW 0

0 0

0 0

0 3

0 0

0 0

0 3

NNW 0

0 0

0 0

2 2

0 0

0 0

0 4

TOTAL 0 0

0 6

9 31 64 10 0

0 0

0 120 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

120 TOTAL HOURS FOR THE FER100:

1?.0 RIVER BEND STATION JOINT FREQUENCY TABLE STA81LITY CLASS G FROM 1/ 1/97 0:00 TO 3/31/97 23:00 PRIMARY SENSORS 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1-1.6-2.1-3.1 5.1 7.1 10.1-13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 NNE O

O 1

1 1

1 0

0 0

0 0

0 4

NE 0

0 0

1 1

2 7

0 0

0 0

0 11 ENE O

O 1

0 0

3 2

1 0

0 0

0 7

E O

0 0

1 2

6 0

0 0

0 0

0 9

ESE 0

0 0

1 0

5 3

0 0

0 0

0 9

SE O

0 0

1 0

2 10 0

0 0

0 0 13 SSE 0

0 0

0 0

0 2

0 0

0 0

0 2

S 0

0 0

1 0

1 2

0 0

0 0

0 4

SSW 0

0 1

2 1

2 0

0 0

0 0

0 6

SW 0

0 0

0 3

6 2

0 0

0 0

0 11 WSW 0

0 0

1 0

7 1

0 0

0 0

0 9

W 0

1 0

1 3

2 0

0 0

0 0

0 7

WNW 0

1 0

0 0

7 1

0 0

0 0

0 9

NW 0

0 0

1 0

3 1

0 0

0 0

0 5

NNW 0

0 0

0 2

4 2

0 0

0 0

0 8

TOTAL 0 2

3 11 14 52 34 1

0 0

0 0 117 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VAL 10 HOURS:

117 TOTAL HOURS FOR THE PERIOD:

117 43

River Bend Station 1997 Regulatory Guide 1.31 April 27.1991 RIUER BEND STAfl0N JOINT FREQUENCY TABLE ALL STABILITY CLASSES FROM 4/ 1/97 0:00 TO 6/30/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

)

WIND.22.51.76 1.1 1.6-2.1-3.1 5.1-7.1 10.1 13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 4

N 7 10 16 29 17 34 14 2

0 0

0 0 129 NNE 9

8 17 56 29 18 2

0 0

0 0

0 139 NE 8

6 11 32 32 40 3

0 0

0 0

0 132 ENE 7 13 4

12 11 17 5

0 0

0 0

0 69 t

E 5

5 12 31 10 10 2

0 0

0 0

0 75 ESE 3 13 21 18 14 21 0

0 0

0 0

0 90 SE 3 13 24 46 45 49 16 0

0 0

0 1 197 SSE 3

10 13 38 49 54 21 9

2 0

0 0 199 i

S 1

7 8 47 64 92 37 2

0 0

0 0 258 SSW 3

6 10 33 26 43 22 0

0 0

0 0 143 SW 0

8 9 15 12 24 8

0 0

0 0

0 76 WSW 1

5 8 16 17 19 2

0 0

0 0

0 68 W

4 10 4 18 20 21 3

0 0

0 0

0 80 WNW 9

17 14 8 11 22 2

0 0

0 0

0 83 NW 14 43 18 18 16 19 2

0 0

0 0

0 110 NNW 10 17 9 28 18 26 26 1

0 0

0 0 135 TOTAL 87 171 198 445 391 509 165 14 2

0 0

1 1983 s

NUM8ER OF CALMS:

i NUMBER OF INVALID HOUR $:

199 NUMBER OF VALID HOURS: 1985 TOTAL HOURS FOR THE PERIOD: 2184 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLAS$ A FROM 4/ 1/97 0:00 TO 6/30/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1-1.6-2.1-3.1-5.1 7.1 10.1 13.1 >18 TOT.

1 l

O!R

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

O O

O O

0 1

2 0

0 0

0 0

3 i

NNE O

0 0

0 0

5 1

0 0

0 0

0 6

1 NE O

0 0

0 1

15 1

0 0

0 0

0 17 ENE O

O O

0 1

4 0

0 0

0 0

0 5

E O

O O

O 0

2 0

0 0

0 0

0 2

ESE 0

0 0

0 0

5 0

0 0

0 0

0 5

SE O

O O

O 2

13 8

0 0

0 0

0 23 SSE O

O O

O 2

8 4

0 0

0 0

0 14 S

0 0

0 0

0 19 18 1

0 0

0 0 38 SSW 0

0 0

0 0

5 6

0 0

0 0

0 11 SW 0

0 0

0 0

1 2

0 0

0 0

0 3

WSW 0

0 0

0 0

4 0

0 0

0 0

0 4

W 0

0 0

0 0

2 1

0 0

0 0

0 3

WW 0

0 0

0 0

1 0

0 0

0 0

0 1

NW 0

0 0

0 0

0 0

0 0

0 0

0 0

NNW 0

0 0

1 0

0 3

0 0

0 0

0 4

TOTAL 0 0

0 1

6 85 46 1

0 0

0 0 139 NUMBER OF CALMS:

0 NUM8ER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

139 TOTAL HOURS FOR THE PERIOD:

139 44

r River iknd Station 1997 Regulatory Guide 1.21 April 27,1998 RIVER BEND STATION JOINT FRETJETCY 7A8LE STABILITY CLASS 8 FROM 4/ 1/97 0:00 To 6/30/97 23:00 PRIMARY SENSORS - 30 FOOT WIND SPEED (METERS /SSCONO) i WIND.22.51

.76-1.1 1.6-2.1 3.1-5.1 7.1-10.1 13.1 >18 TOT.

l DIR

.50. T5 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

O O

O 0

0 7

6 0

0 0

0 0 13 l

l NNE O

0 1

0 1

1 0

0 0

0 0

0 3

i NE 0

0 0

3 5

6 0

0 0

0 0

0 14 ENE 0

0 0

0 2

2 0

0 0

0 0

0 4

E 0

0 0

3 2

1 0

0 0

0 0

0 6

ESE O

O O

1 4

2 0

0 0

0 0

0 7

SE 0

0 0

0 6

6 1

0 0

0 0

0 13 SSE 0

0 0

1 2

5 1

1 0

0 0

0 10 S

0 0

0 0

4 14 5

1 0

0 0

0 24 SSW 0

0 0

0 4

8 8

0 0

0 0

0 20 SW 0

0 0

0 4

4 4

0 0

0 0

0 12 WSW 0

0 0

0 5

4 0

0 0

0 0

0 9

W 0

0 0

0 6

6 1

0 0

0 0

0 13 WNW 0

0 0

0 1

11 2

0 0

0 0

0 14 NW 0

0 0

0 1

6 1

0 0

0 0

0 8

NNW 0

0 0

0 0

3 8

1 0

0 0

0 12 TOTAL 0 0

1 8 47 86 37 3

0 0

0 0 182 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

182 TOTAL HOURS FOR THE PERIOD:

182 RIVER BENO STATION JOINT FREQUENCY TABLE STABILITY O ASS C FROM 4/ 1/97 0:00 TO 6/30/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (NETERS/SECOND)

WIND.22.51

.76-1.1 1.6 2.1 3.1 5.1 7.1 10.1-13.1 >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 2

2 3

1 0

0 0

0 0

8 NNE O

O O

2 5

0 1

0 0

0 0

0 8

NE O

0 0

4 2

3 0

0 0

0 0

0 9

ENE O

O O

2 0

1 0

0 0

0 0

0 3

E O

0 0

1 0

0 0

0 0

0 0

0 1

ESE O

O O

0 0

1 0

0 0

0 0

0 1

SE 0

0 0

1 4

0 0

0 0

0 0

1 6

$$E 0

0 0

1 1

4 0

0 0

0 0

0 6

S 0

0 0

1 3

6 3

0 0

0 0

0 13 SSW 0

0 0

1 3

2 2

0 0

0 0

0 8

i SW 0

0 0

0 2

5 0

0 0

0 0

0 7

WSW 0

0 0

3 2

2 0

0 0

0 0

0 7

W 0

0 0

2 6

6 0

0 0

0 0

0 14 WNW 0

0 0

0 1

5 0

0 0

0 0

0 6

l NW 0

0 1

1 3

6 1

0 0

0 0

0 12 l

NNW 0

0 0

0 1

5 5

0 0

0 0

0 11 TOTAL 0 0

1 21 35 49 13 0

0 0

0 1 120 j

NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

120 TOTA!. HOURS FOR THE PERIOD:

120 i

45 i

I

l l

River fled Station 1997 ftgulatory Guide 1.31 April 37.19f 8 j

RIVER BENO STATION l

JOINT FREQUENCY TABLE l

STABILITY CLASS D I

FROM 4/ 1/97 0:00 TO 6/30/97 23:00 I

PRIMARY SENSORS - 30 FOOT l

l WIND SPEED (METERS /SECONO) l WIND.22.51

.76 1.1 - 1.6 2.1 3.1 - 5.1 7.1-10.1 - 13.1- >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

3 11 9 17 5

2 0

0 0

0 47 NNE 0

0 1

16 10 6

0 0

0 0

0 0 33 NE O

0 3

11 8

5 1

0 0

0 0

0 28 ENE 0

2 3

6 6

5 5

0 0

0 0

0 27 E

O O

5 17 5

5 2

0 0

0 0

0 34 ESE O

0 5

7 6

8 0

0 0

0 0

0 26 SE O

O 6 23 14 22 5

0 0

0 0

0 70 SSE O

O 2 10 20 25 10 4

0 0

0 0 71 S

0 0

2 6 22 25 8

0 0

0 0

0 63 SSW 0

0 2

9 10 16 6

0 0

0 0

0 43 SW 0

0 2

5 4

12 2

0 0

0 0

0 25 WSW 0

0 0

9 10 8

1 0

0 0

0 0 28 W

0 0

2 12 5

7 1

0 0

0 0

0 27 WNW 0

0 4

7 8

4 0

0 0

0 0

0 23 NW 0

0 1

7 8

5 0

0 0

0 0

0 21 NNW 0

0 1

14 8

16 9

0 0

0 0

0 48 TOTAL 0 2 42 170 153 186 55 6

0 0

0 0 614 NUMBER OF CALMS:

0 NUM8ER OF INVALID HOURS:

0 NUMBER OF VALID HOURS: 614 TOTAL HOURS FOR THE PERIOD:

614 RIVER BENO STATION JOINT FREQUENCY TABLE STABILITY CLASS E FROM 4/ 1/97 0:00 To 6/30/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1 1.6 2.1 3.1-5.1 7.1 10.1 13.1- >18 TOT.

I DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 4

6 10 5

6 0

0 0

0 0

0 31 i

NNE 1

3 7 14 11 6

0 0

0 0

0 0 42 1

NE O

O 7 13 14 11 1

0 0

0 0

0 46 i

ENE 0

6 1

4 2

5 0

0 0

0 0

0 18 l

E 1

3 7

8 3

2 0

0 0

0 0

0 24 j

l ESE 1

7 12 10 4

5 0

0 0

0 0

0 39 i

l SE 2

9 14 21 18 8

1 0

0 0

0 0 73

)

SSE 2

7 9 23 23 12 4

4 2

0 0

0 86

{

S 0

5 4 31 35 28 3

0 0

0 0

0 106

$$W 0

3 6 18 9 12 0

0 0

0 0

0 48 SW 0

6 2

6 1

2 0

0 0

0 0

0 17 WSW 1

2 7

4 0

1 1

0 0

0 0

0 16 W

0 1

0 4

3 0

0 0

0 0

0 0

8 WNW 0

4 4

1 1

1 0

0 0

0 0

0 11 NW 0

2 5

6 3

1 0

0 0

0 0

0 17 NNW 0

1 3

6 7

2 1

0 0

0 0

0 20 TOTAL 8 63 94 1 79 139 102 11 4

2 0

0 0 602 NUMBER OF CALMS:

0-NUM8ER OF INVALID HOURS:

0 NUMBER OF VALID HOURS: 602 TOTAL HOURS FOR THE PERIOD:

602 46

.. ~

River Ihd Station 1997 R gul;AoryGuide 121 April 27.1998 RIVER BEND STATION JolNT FREQUENCY TABLE STABILITY CLASS F FROM 4/ 1/97 0:00 To 6/30/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1 1.6-2.1 3.1 5.1 7.1 10.1 13.1- >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

3 2

2 4

1 0

0 0

0 0

0 0 12 NNE 2

2 4 21 2

0 0

0 0

0 0

0 31 NE 2

1 0

1 1

0 0

0 0

0 0

0 5

ENE 1

3 0

0 0

0 0

0 0

0 0

0 4

E 2

2 0

2 0

0 0

0 0

0 0

0 6

ESE 1

4 3

0 0

0 0

0 0

0 0

0 8

SE 1

3 4

1 1

0 0

0 0

0 0

0 10 SSE O

1 0

2 1

0 0

0 0

0 0

0 4

S 1

2 2

9 0

0 0

0 0

0 0

0 14

$$W 2

2 2

4 0

0 0

0 0

0 0

0 10 SW 0

0 5

3 1

0 0

0 0

0 0

0 9

WW 0

3 1

0 0

0 0

0 0

0 0

0 4

W 3

4 0

0 0

0 0

0 0

0 0

0 7

WNW 1

4 3

0 0

0 0

0 0

0 0

0 8

NW 4

5 4

2 0

0 0

0 0

0 0

0 15 NNW 1

4 2

3 2

0 0

0 0

0 0

0 12 TOTAL 24 42 32 52 9

0 0

0 0

0 0

0 159 NUMBER OF CALMS:

0 NUM8ER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

159 TOTAL HOURS FOR THE PERIOD:

159 RIVER BEND STATION JOINT FREQUENCY TABLE j

STABILITY CLASS G i

FROM 4/ 1/97 0:00 TO 6/30/97 23:00 PRIMARY SENSORS 30 F00T WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1-1.6-2.1 3.1 5.1-7.1 10.1 13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

4 4

5 2

0 0

0 0

0 0

0 0 15 NNE 6

3 4

3 0

0 0

0 0

0 0

0 16 NE 6

5 1

0 1

0 0

0 0

0 0

0 13 ENE 6

2 0

0 0

0 0

0 0

0 0

0 8

E 2

0 0

0 0

0 0

0 0

0 0

0 2

ESE 1

2 1

0 0

0 0

0 0

0 0

0 4

SE 0

1 0

0 0

0 1

0 0

0 0

0 2

SSE 1

2 2

1 0

0 2

0 0

0 0

0 8

S 0

0 0

0 0

0 0

0 0

0 0

0 0

SSW 1

1 0

1 0

0 0

0 0

0 0

0 3

SW 0

2 0

1 0

0 0

0 0

0 0

0 3

WSW 0

0 0

0 0

0 0

0 0

0 0

0 0

1 W

1 5

2 0

0 0

0 0

0 0

0 0

8 WNW 8

9 3

0 0

0 0

0 0

0 0

0 20 NW 10 16 7

2 1

1 0

0 0

0 0

0 37 NNW 9 12 3

4 0

0 0

0 0

0 0

0 28 TOTAL 55 64 28 14 2

1 3

0 0

0 0

0 167 NUMBER OF CALMS:

2 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOUR $

169 TOTAL HOURS FOR THE PERIOD:

169 47 l

i 4

1

River Hend Station 1997 Regulatory Guide 1.31 April 27.1998

)

RIVER 8END STATION l

JOINT FREQUENCY TABLE ALL STABILITY CLASSES 1

FROM 4/ 1/97 0:00 TO 6/30/97 23:00 PRIMARY SENSORS 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1 1.6-2.1-3.1 5.1-7.1-10.1 13.1- >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 1

0 10 7 19 62 3

1 1

0 0 104 NNE O

O 3

3 8 31 39 0

0 0

0 0 84 NE O

2 1

7 20 27 96 9

0 1

0 0 163 ENE O

O 1

6 10 31 49 29 7

0 0

0 133 j

E O

O 3 to 15 28 26 16 3

0 0

1 102 ESE 0

0 1

10 16 39 93 35 0

0 0

1 1 95 SE O

O 1

5 10 45 53 16 4

1 0

0 135 SSE O

1 1

6 20 48 51 9

6 1

0 0 143 S

0 0

1 5 10 72 144 12 1

0 0

0 245 SSW 0

0 4

6 15 52 83 11 1

0 0

0 1 72 SW 1

0 1

6 17 28 31 3

0 0

0 0 87 WSW 0

1 0

8 18 32 30 3

0 0

0 0 92 W

0 0

0 13 14 37 26 2

0 0

0 0 92 WNW 0

0 4

5 16 19 15 1

1 0

0 0 61 NW 1

0 3

8 7 25 25 1

1 0

0 0 71 NNW 0

0 1

4 14 31 37 18 1

0 0

0 106 TOTAL 2 5 25 112 217 564 860 168 26 4

0 2 1985 NUMBER OF CALMS:

0 NUMSER OF INVALIO HOURS:

199 NUMBER OF VALID HOURS: 1985 TOTAL HOURS FOR THE PERIOD: 2184 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS A FROM 4/ 1/97 0:00 TO 6/30/97 2'1:00 PRIMARY SENSORS 150 FOOT WIND SPEED (METERS /SECOND) 3 WIND.22.51 76 1.1-1.6-2.1 3.1 5.1 7.1 10.1-13.1 >18 TOT.

j DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 i

N 0

0 0

0 0

0 3

0 0

0 0

0 3

NNE 0

0 0

0 0

0 6

0 0

0 0

0 6

NE O

O O

O O

1 12 1

0 0

0 0 14 ENE 0

0 0

0 0

1 2

5 0

0 0

0 8

E 0

0 0

0 0

0 5

0 0

0 0

1 6

ESE O

O O

O O

2 7

9 0

0 0

1 19 SE O

0 0

0 0

2 6

3 0

0 0

0 11 SSE O

O O

0 0

2 9

1 0

0 0

0 12 S

0 0

0 0

0 3 26 3

1 0

0 0 33 SSW 0

0 0

0 0

1 8

4 0

0 0

0 13 SW 0

0 0

0 0

0 2

1 0

0 0

0 3

WW 0

0 0

0 0

1 4

0 0

0 0

0 5

)

W 0

0 0

0 0

0 2

1 0

0 0

0 3

WNW 0

0 0

0 0

0 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

0 0

0 0

0 0

NNW 0

0 0

0 1

0 0

2 0

0 0

0 3

TOTAL 0 0

0 0

1 13 92 30 1

0 0

2 139 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

139 TOTAL HOURS FDR THE PERIOD:

139 48

River Dend Static 1997 Regulatory Guide 1,21 April 37.1998 RIVER BEND STATION JolNT FREQUENCY VABLE STA81LITY CLASS B FROM 4/ 1/97 0:00 TO 6/30/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1 1.6 2.1 3.1 5.1 7.1 10.1 13.1 >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 0

0 1

9 2

0 0

0 0 12 NNE O

O 1

0 0

0 1

0 0

0 0

0 2

NE 0

0 0

0 1

5 5

0 0

0 0

0 11 ENE O

O 0

1 0

4 3

1 0

0 0

0 9

E O

O O

O 0

2 4

2 0

0 0

0 8

ESE 0

0 0

0 0

6 4

4 0

0 0

0 14 SE O

0 0

0 0

3 3

1 0

0 0

0 7

SSE 0

0 0

0 1

4 2

1 0

0 0

0 8

S 0

0 0

0 1

9 10 2

0 0

0 0 22 SSW 0

0 0

0 0

6 8

4 0

0 0

0 18 SW D

0 0

0 2

2 10 0

0 0

0 0 14 WSW 0

0 0

0 1

6 2

0 0

0 0

0 9

W 0

0 0

0 0

8 12 0

0 0

0 0 20 WWW 0

0 0

0 0

5 4

1 1

0 0

0 11 NW 0

0 0

0 0

1 3

0 0

0 0

0 4

NNW 0

0 0

0 0

1 5

6 1

0 0

0 13 TOTAL 0 0

1 1

6 63 85 24 2

0 0

0 182 NUMBER OF CALMS:

0 NUM8ER OF INVALIO HOURS:

0 NUMBER OF VALID HOURS:

182 TOTAL HOURS FOR THE PERIOD:

182 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS C FROM 4/ 1/97 0:00 TO 6/30/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1-1.6-2.1 3.1 5.1 7.1 10.1 13.1- >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 2

0 2

3 0

0 0

0 0

7 NNE 0

0 0

0 0

4 1

0 0

0 0

0 5

NE 0

0 0

0 4

4 4

1 0

0 0

0 13 ENE O

0 0

0 1

0 1

0 0

0 0

0 2

E O

O 0

0 1

1 0

1 0

0 0

0 3

ESE O

0 0

0 0

1 1

1 0

0 0

0 3

SE O

O 0

0 0

2 1

0 0

0 0

0 3

$$E O

O O

O 1

2 2

0 0

0 0

0 5

S 0

0 0

0 1

3 6

2 0

0 0

0 12 SSW 0

0 0

0 1

4 3

1 0

0 0

0 9

SW 0

0 0

0 0

4 3

0 0

0 0

0 7

WSW 0

0 0

0 4

3 3

0 0

0 0

0 10 W

0 0

0 0

3 7

2 0

0 0

0 0 12 WW 0

0 0

1 1

2 4

0 0

0 0

0 8

NW 0

0 0

1 1

6 4

0 1

0 0

0 13 NNW 0

0 0

0 0

3 2

3 0

0 0

0 8

TOTAL 0 0

0 4 18 48 40 9

1 0

0 0 120 NUM8ER OF CALMS:

0 NUMBER 0F INVALID HOURS:

0 NUMBER OF VALID HOURS:

120 TOTAL HOURS FOR 1HE PERIDO:

120 49

River Bei Statio 1997 Regulatory Guido 1.21 Apnl27.1998 RIVER BEND STATION J0!N7 FREQUENCY TABLE STABILITY CLASS D FROM 4/ 1/97 0:00 To 6/30/97 23:00 PRIMARY SENSORS - 150 FOOT WINO SPEED (METERS /SECOND)

WIND.22.51.76 1.1-1.6 2.1-3.1-5.1 7.1 10.1-13.1 >18 T07.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 5

6 6 21 1

1 1

0 0 41 NNE O

O 0

3 4

7 3

0 0

0 0

0 17 NE O

1 1

5 9

6 19 4

0 1

0 0 46 ENE 0

.0 0

1 6 12 16 6

6 0

0 0 47 E

O 0

0 3

8 7

6 9

2 0

0 0 35 ESE O

O O

6 7 15 21 13 0

0 0

0 62 SE O

O O

1 5

12 19 8

1 0

0 0 46 SSE O

0 0

3 7 13 17 5

4 0

0 0 49 S

0 0

0 2

3 19 26 3

0 0

0 0 53 SSW 0

0 1

2 2

9 27 1

1 0

0 0 43 SW 0

0 0

3 5

6 10 2

0 0

0 0 26 WSW 0

0 0

3 5

7 17 2

0 0

0 0 34 W

0 0

0 5

7 9

6 1

0 0

0 0 28 WNW 0

0 1

1 6

8 3

0 0

0 0

0 19 NW 0

0 2

4 4

9 9

1 0

0 0

0 29 NNW 0

0 0

2 10 7 14 6

0 0

0 0 39 TOTAL 0 1

5 49 94 152 234 62 15 2

0 0 614 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS: 614 TOTAL HOURS FOR THE PERIOD: 614 RIVER BEND STATION J0!NT FREQUENCY TABLE STABILITY CLASS E FROM 4/ 1/97 0:00 To 6/30/97 23:00 PRIMARY SENSORS 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51 76 1.1 1.6 2.1 3.1 5.1 7.1 10.1 13.1- >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 1

0 7 11 0

0 0

0 0 19 NNE 0

0 0

0 1

11 15 0

0 0

0 0 27 I

NE O

O O

O 5

4 36 2

0 0

0 0 47 I

ENE O

O 1

3 1

9 15 13 1

0 0

0 43 E

0 0

0 4

4 11 10 4

1 0

0 0 34 ESE O

0 1

4 7 13 53 8

0 0

0 0 86 SE 0

0 0

2 2 21 18 1

3 1

0 0 48 SSE 0

0 0

1 7 20 17 2

2 1

0 0 50 S

0 0

0 1

4 26 66 2

0 0

0 0 99 SSW 0

0 2

2 4 21 33 1

0 0

0 0 63 SW 0

0 1

0 4

9 4

0 0

0 0

0 18 WSW 0

1 0

3 4

9 2

1 0

0 0

0 20 W

0 0

0 1

1 4

3 0

0 0

0 0

9 WW 0

0 1

2 2

0 3

0 0

0 0

0 8

i NW 0

0 0

2 0

3 5

0 0

0 0

0 10 NNW 0

0 0

0 1

10 9

1 0

0 0

0 21 TOTAL 0 1

6 26 47 178 300 35 7

2 0

0 602 NUM8ER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS: 602 TOTAL HOURS FOR THE PEkl00: 602 50

Riter llend Station 1997 legulatory Guide 1.21 April 27.1998 RISER BEND STA710N JOINT FREQUENCY TABLE STABILITY CLASS F 1

FROM 4/ 1/97 0:00 TO 6/30/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1 1.6 2.1-3.1 5.1 7.1-10.1 13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 0

1 0

2 0

0 0

0 0

3 NNE O

O 2

0 1

4 5

0 0

0 0

0 12 NE O

O O

1 1

2 16 1

0 0

0 0 21 ENE 0

0 0

1 0

2 11 4

0 0

0 0 18 E

O O

O 1

2 2

1 0

0 0

0 0

6 ESE O

0 0

0 0

1 4

0 0

0 0

0 5

SE O

O 1

2 3

4 3

0 0

0 0

0 13 SSE O

O O

2 3

5 2

0 0

0 0

0 12 S

0 0

0 2

1 5

8 0

0 0

0 0 16 SSW 0

0 1

1 7

8 3

0 0

0 0

0 20 SW 0

0 0

1 1

5 1

0 0

0 0

0 8

WSW 0

0 0

1 2

1 0

0 0

0 0

0 4

W 0

0 0

1 1

2 0

0 0

0 0

0 4

WNW 0

0 1

0 1

1 0

0 0

0 0

0 3

NW 0

0 0

1 0

2 0

0 0

0 0

0 3

NNW 0

0 0

1 1

3 6

0 0

0 0

0 11 TOTAL 0 0

5 15 25 47 62 5

0 0

0 0 159 NUM8ER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

159 1

TOTAL HOURS FOR THE PERIDO:

159 1

RIVER' BEND STATION I

JOINT FREQUENCY TABLE STABILITY CLASS 0 FROM 4/ 1/97 0:00 TO 6/30/97 23:00 1

PRIMARY SENSORS 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1 1.6 2.1 3.1 5.1 7.1 10.1 13.1 >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

O 1

0 2

0 3

13 0

0 0

0 0 19 NNE 0

0 0

0 2

5 8

0 0

0 0

0 15 NE O

1 0

1 0

5 4

0 0

0 0

0 11 ENE 0

0 0

0 2

3 1

0 0

0 0

0 6

E O

O 3

2 0

5 0

0 0

0 0

0 10 ESE O

O 0

0 2

1 3

0 0

0 0

0 6

SE O

O O

O O

1 3

3 0

0 0

0 7

SSE O

1 1

0 1

2 2

0 0

0 0

0 7

S 0

0 1

0 0

7 2

0 0

0 0

0 10 SSW 0

0 0

1 1

3 1

0 0

0 0

0 6

SW 1

0 0

2 5

2 1

0 0

0 0

0 11 WSW 0

0 0

1 2

5 2

0 0

0 0

0 10 W

0 0

0 6

2 7

1 0

0 0

0 0 16 WNW 0

0 1

1 6

3 1

0 0

0 0

0 12 NW 1

0 1

0 2-4 4

0 0

0 0

0 12 NNW 0

0 1

1 1

7 1

0 0

0 0

0 11 TOTAL 2 3

8 17 26 63 47 3

0 0

0 0 169 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

169 TOTAL HOURS FOR THE PER100:

169 51

i River Bend Station 1997 Regulatory Guide 1.21 April 37.1998 RIVER BEND STATION JOINT FREQUENCY TABLE ALL STABILITY CLASSES

(

FROM 7/ 1/97 0:00 TO 9/30/97 23:00 f

PRIMARY SENSORS - 30 FOOT l

WIND SPEED (METERS /SECOND)

I WIND.22.51

.76 1.1 1.6-2.1-3.1-5.1-7.1-10.1-13.1- >18 TOT.

DlR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

(

N 14 20 22 39 34 27 3

0 0

0 0

0 159

(

NNE 13 16 17 51 49 17 1

0 0

0 0

0 164 j

NE 14 24 32 28 26 12 0

0 0

0 0

0 136 ENE 20 14 21 33 16 6

0 0

0 0

0 0 110 E

13 14 27 19 17 1

0 0

0 0

0 0 91 ESE 6 17 20 26 15 6

0 0

0 0

0 0 90 SE 3

6 23 44 14 14 2

0 0

0 0

0 106 j

SSE 2

5 9 25 27 21 2

0 0

0 0

0 91 i

S 4

3 11 22 26 20 10 0

0 0

0 0 96 SSW 4

8 8 28 7 15 5

0 0

0 0

0 75 SW 3

6 16 23 14 8

0 0

0 0

0 0 70 WSW 4

14 16 20 17 21 0

0 0

0 0

0 92 W

9 19 18 19 42 39 0

0 0

0 0

0 146 WNW 10 46 31 42 25 20 0

0 0

0 0

0 174 NW 19 64 29 30 36 27 2

0 0

0 0

0 207 NNW 27 26 21 31 36 43 6

0 0

0 0

0 190 TOTAL 165 302 321 480 401 297 31 0

0 0

0 0 1997 NbkBEit b bELkh$

kk j

NUMBER OF INVALID HOURS: 200 NUMBER OF VAllD HOUR $s 2008 TOTAL HOURS FOR THE PERIOD: 2208 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS A i

FROM 7/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1-1.6-2.1-3.1 5.1 7.1-10.1 13.1- >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 0

0 8

1 0

0 0

0 0

9 NNE 0

0 0

0 0

0 0

0 0

0 0

0 0

NE 0

1 0

0 4

5 0

0 0

0 0

0 10 ENE O

O O

O 3

3 0

0 0

0 0

0 6

E 0

0 0

1 4

0 0

0 0

0 0

0 5

ESE 0

0 0

0 5

6 0

0 0

0 0

0 11 SE O

0 0

0 2

7 1

0 0

0 0

0 10 SSE O

O 0

0 2

4 0

0 0

0 0

0 6

S 0

0 0

1 1

1 7

0 0

0 0

0 10 SSW 0

0 0

0 0

7 1

0 0

0 0

0 8

SW 0

0 0

0 6

2 0

0 0

0 0

0 8

WSW 0

0 0

0 3

8 0

0 0

0 0

0 11 W

0 0

0 0

2 7

0 0

0 0

0 0

9 WNW 0

0 0

0 1

6 0

0 0

0 0

0 7

NW 0

0 0

0 1

3 1

0 0

0 0

0 5

NNW 0

0 0

0 1

5 4

0 0

0 0

0 10 TOTAL 0 1

0 2 35 72 15 0

0 0

0 0 125 NUMBER OF CALMS:

0 NUMBER OF INVALID HOUR $:

0 NUMBER OF VALID HOURS:

125 TOTAL HOURS FOR THE PSRIOD:

125 52

River Iknd Station 1997 Regulatory Guide 1.31 April 37.1998 l

RISER SEND STATION JOINT FREQUENCY TA8LE STA81LITY CLASS 8 FROM 7/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENSORS - 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1 1.6-2.1 3.1-5.1 7.1 10.1 13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 O

O O

3 7

0 0

0 0

0 0 10 NNE O

0 0

0 18 5

0 0

0 0

0 0 23 NE O

0 0

1 11 5

0 0

0 0

0 0 17 ENE O

O O

2 5

0 0

0 0

0 0

0 7

E O

O O

2 3

0 0

0 0

0 0

0 5

ESE O

0 0

3 4

0 0

0 0

0 0

0 7

SE O

.0 0

3 1

1 1

0 0

0 0

0 6

SSE 0

0 0

0 2

1 0

0 0

0 0

0 3

S 0

0 0

0 3

2 2

0 0

0 0

0 7

SSW 0

0 0

0 1

1 3

0 0

0 0

0 5

SW 0

0 0

1 3

1 0

0 0

0 0

0 5

WSW 0

0 0

2 6

8 0

0 0

0 0

0 16 l

W 0

0 0

1 15 28 0

0 0

0 0

0 44 l

WNW 0

0 0

0 9

7 0

0 0

0 0

0 16 l

NW 0

0 0

0 4 14 0

0 0

0 0

0 18 NNW 0

0 0

0 8

9 1

0 0

0 0

0 18 TOTAL 0 0

0 15 96 89 7

0 0

0 0

0 207 NUM8ER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUM8ER OF VALID HOURS: 207 TOTAL NOURS FOR THE PERIOD: 207 J

1 RIVER BEND STATION J0!NT FREQUENCY TA8LE STA81LITY CLASS C FROM 7/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENSORS - 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1 1.6-2.1-3.1 5.1 7.1-10.1 13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 1

3 5

0 0

0 0

0 0

9 NNE 0

0 0

2 7

2 0

0 0

0 0

0 11 NE O

O O

2 3

0 0

0 0

0 0

0 5

ENE O

O O

3 2

0 0

0 0

0 0

0 5

E O

0 0

2 2

0 0

0 0

0 0

0 4

ESE 0

0 0

1 1

0 0

0 0

0 0

0 2

SE 0

0 0

3 1

1 0

0 0

0 0

/

5 SSE 0

0 0

2 0

0 1

0 0

0 0

0 3

S 0

0 0

0 2

0 1

0 0

0 0

0 3

9 SSW 0

0 0

2 0

0 0

0 0

0 0

0 2

l SW 0

0 0

2 2

1 0

0 0

0 0

0 5

WSW 0

0 0

4 3

2 0

0 0

0 0

0 9

W 0

0 0

2 11 3

0 0

0 0

0 0 16 WNW 0

0 0

2 6

4 0

0 0

0 0

0 12 l

NW 0

0 0

7 8

5 0

0 0

0 0

0 15 NNW 0

0 0

2 6

5 1

0 0

0 0

0 14 r

NUM8ER OF CALMS:

0 NUM8ER OF INVALID HOURS:

0 NUM8ER OF VALID HOUR $:

120 TOTAL HOURS FOR THE PERIOD:

  • 20 53

i River Bend Statica 1997 Regulatcy Guide 1.21 Apil 27,1998 RISER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS D FROM 7/ 1/97 0:00 T.1 9/30/97 23:00 PRIMARY SENSORS - 30 FOOT WINO SPEED (METERS /SECONO)

WIND.22.51

.76-1.1 1.6-2.1-3.1 5.1 7.1-10.1-13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 1

4 5 18 4

2 0

0 0

0 0 34 NNE D

1 1

70 13 4

1 0

0 0

0 0 40 NE 0

1 7

9 3

1 0

0 0

0 0

0 21 ENE 1

2 2 16 3

3 0

0 0

0 0

0 27 E

O 0

6 11 5

1 0

0 0

0 0

0 23 i

ESE O

1 7 11 4

0 0

0 0

0 0

0 23 SE O

O 5 10 8

4 0

0 0

0 0

0 27 SSE O

O 2

8 8 11 1

0 0

0 0

0 30 S

0 0

2 2

5 11 0

0 0

0 0

0 20

$$W 0

0 2

7 4

6 1

0 0

0 0

0 20 SW 0

0 2

1 1

3 0

0 0

0 0

0 7

WSW 0

0 4

8 3

3 0

0 0

0 0

0 18 W

0 0

2 11 12 1

0 0

0 0

0 0 26 WNW 0

0 3 18 8

2 0

0 0

0 0

0 31 NW 0

0 3 20 20 4

1 0

0 0

0 0 48 NNW 0

4 2 15 18 21 0

0 0

0 0

0 60

)

TOTAL 1 10 54 172 133 79 6

0 0

0 0

0 455 NUMBER OF CALMS:

0 NUM8ER OF INVALID HOURS:

0 NUNSER OF VALID HOURS: 455 TOTAL COURS FOR THE PERIOD: 455 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS E FROM 7/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1-1.6 2.1-3.1 5.1 7.1 10.1 13.1- >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

.~......................................................................

N O

5 9

9 7

3 0

0 0

0 0

0 33 i

NNE 2

4 9 23 11 6

0 0

0 0

0 0 55 l

NE 1

8 15 13 5

1 0

0 0

0 0

0 43 ENd 2

5 11 10 3

0 0

0 0

0 0

0 31 E

9 5 18 3

3 0

0 0

0 0

0 0 29 i

ESE 1

8 10 11 1

0 0

0 0

0 0

0 31 l

SE 0

3 17 24 1

1 0-0 0

0 0

0 46

$$E 1

2 7 14 15 5

0 0

0 0

0 0 44 S

1 1

6 15 13 6

0 0

0 0

0 0 42 SSW 2

4 7 14 2

1 0

0 0

0 0

0 25 SW 0

1 9 17 2

1 0

0 0

0 0

0 30 w3W 0

7 5

1 0

0 0

0 0

0 0 19 W

n 7

0 3

2 0

0 0

0 0

0 0 22 Whd

(

0 10 1

1 0

0 0

0 0

0 38 NW 5

7 7

3 1

0 0

0 0

0 0 25 NEW 7

7 2

3 0

0 0

0 0

0 24 TOT. i3 75 154 194 72 29 0

0 0

0 0

0 537 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID nUR$: 537 TOTAL HOURS FOR inE PER100: 537

]

54 1

l 1

River Bend Station 1997 R gulatory Guide 1.21 April 27.1998 RlYER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS F FROM 7/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENS0RS - 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1 1.6-2.1-3.1-5.1-7.1 90.1-13.1 >18 TOT.

0!R

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 i

N 5

5 6 16 1

0 0

0 0

0 0

0 33 NNE 3

6 5

5 0

0 0

0 0

0 0

0 19 NE 4

7 9

3 0

0 0

0 0

0 0

0 23 ENE 2

4 8

2 0

0 0

0 0

0 0

0 16 E

5 7

2 0

0 0

0 0

0 0

0 0 14 ESE 2

5 3

0 0

0 0

0 0

0 0

0 10 SE 3

1 0

4 1

0 0

0 0

0 0

0 9

SSE 0

2 0

1 0

0 0

0 0

0 0

0 3

S 1

1 3

3 2

0 0

0 0

0 0

0 10 SSW 2

4 4

5 0

0 0

0 0

0 0

0 15 SW 2

2 3

2 0

0 0

0 0

0 0

0 9

WSW 0

5 2

1 0

0 0

0 0

0 0

0 8

W 3

5 4

2 0

0 0

0 0

0 0

0 14 WNW 2 14 10 3

0 0

0 0

0 0

0 0 29 NW 2 13 8

1 0

0 0

0 0

0 0

0 24 NNW 4

6 5

2 1

0 0

0 0

0 0

0 18

' TOTAL 40 87 72 50 5

0 0

0 0

0 0

0 254 i

f NUMBER OF CALMS:

1 NUM6ER OF INVALID HOURS:

0 NUM8ER 'JF VALID HOURS:

255 TOTAL HOURS FOR THE PERIOD: 255 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS G FROM 7/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND) 1 WIND.22.51

.76-1.1 1.6 2.1-3.1 5.1 7.1 10.1-13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

9 9

3 8

?

0 0

0 0

0 0

0 31

)

l NNE 8

5 2

1 0

0 0

0 0

0 0

0 16 NE 9

7 1

0 0

0 0

0 0

0 0

0 17 ENE 15 3

0 0

0 0

0 0

0 0

0 0 18 E

8 2

1 0

0 0

0 0

0 0

0 0 11 ESE 3

3 C

0 0

0 0

0 0

0 0

0 6

SE O

2 1

0 0

0 0

0 0

0 0

0 3

SSR 1

1 0

0 0

0 0

0 0

0 0

0 2

S 2

1 0

1 0

0 0

0 0

0 0

0 4

SSW 0

0 0

0 0

0 0

0 0

0 0

0 0

SW 1

3 2

0 0

0 0

0 0

0 0

0 6

WSW 4

3 3

0 1

0 0

0 0

0 0

0 11 W

6 7

2 0

0 0

0 0

0 0

0 0 15 WWW 7 26 8

0 0

0 0

0 0

0 0

0 41 NW 16 45 11 0

0 0

0 0

0 0

0 0 72 NNW 22 12 7

5 0

0 0

0 0

0 0

0 46 TOTAL 111 129 41 15 3

0 0

0 0

0 0

0 299 NUMBER OF CALMS:

10 NUMBER OF INVAllo HOURS:

0 NUMBER OF VALID HOURS: 309 TOTAL HOURS FOR THE PERIOD: 309 55

River Bend Station 1997 R:gulatory Guide 1.21 April 27.1998 RIVER BEND STATION JOINT FREQUENCY TABLE ALL STABILITY CLASSES FROM 7/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENSORS 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1-1.6-2.1-3.1-5.1-7.1 10.1-13.1- >18 TOT.

DIR

.50. 75 1.0 1.5 2.U 3.0 5.0 7.0 10.0 13.0 18.0 N

0 1

4 10 16 42 35 1

0 0

0 0 109 NME O

2 5 14 22 37 56 1

0 0

0 0 137 NE 1

1 2 13 15 52 88 0

1 0

0 0 1 73 ENE 1

0 2

8 25 56 62 2

0 0

0 0 156 E

1 0 10 13 21 51 24 2

0 0

0 0 122 ESE 0

0 0 10 21 53 48 4

0 0

0 0 136 SE 0

1 2 16 19 36 37 0

0 0

0 0 111 SSE 0

0 4 12 16 24 17 0

0 0-0 0 73 S

0 0

0 9 13 30 39 2

1 0

0 0 94 SSW 0

0 1

8 17 45 35 2

0 0

0 0 108 SW 0

0 2

6 16 39 16 0

0 0

0 0 79 WSW 0

1 1

15 22 64 24 0

0 0

0 0 127 W

0 3

2 11 17 97 28 0

9 0

0 0 158 WWW 0

0 3 12 18 74 33 0

0 0

0 0 140 NW 0

1 4

9 28 68 22 2

0 0

0 0 134 NNW 0

0 5 11 25 52 56 2

0 0

0 0 151 TOTAL 3 10 47 177 311 820 620 18 2

0 0

0 2008 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS: 200 NUMBER OF VALID HOURS: 2008 TOTAL HOURS FOR THE PERIOD: 2208 RIVER BEND STATION JOINT FRELUENCY TABLE STABILITY CLASS A i

FROM 7/ t/97 0:00 TO 9/30/97 23:00 i

PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

(

WIND.22.51

.76-1.1 1.6 2.1-3.1 5.1 7.1 10.1 13.1 >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

O O

O O

0 0

3 0

0 0

0 0

3 NNE O

O O

0 0

0 6

0 0

0 0

0 6

NE O

O 1

0 0

0 5

9 0

0 0

0 6

ENE O

O O

0 0

2 8

0 0

0 0

0 10 E

O 0

0 0

0 6

4 2

0 0

0 0 12 ESE O

O 0

0 1

5 4

3 0

0 0

0 13 SE O

O O

O O

3 4

0 0

0 0

0 7

SSE O

O 0

0 0

0 0

0 0

0 0

0 0

J S

0 0

0 0

0 0

5 1

1 0

0 0

7 4

SSW 0

0 0

0 2

3 7

0 0

0 0

0 12 SW 0

0 0

0 0

4 2

0 0

0 0

0 6

WSW 0

0 0

J 0

9 7

0 0

0 0

0 16 W

0 0

0 0

0 5

3 0

0 0

0 0

8 WW D

0 0

0 0

0 5

0 0

0 0

0 5

NW 0

0 0

0 0

1 3

1 0

0 0

0 5

NNW 0

0 0

0 0

2 6

1 0

0 0

0 9

TOTAL 0 0

1 0

3 40 72 8

1 0

0 0 125 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

125 TOTAL HOURS FOR THE PERIOD:

125 56

River 13end Statio 1997 Regulatory Guide 1.31 April 27,1998 RIVER BEND STATION JOINT FREQUENCY 7ABLE STABILITY CLASS S FROM 7/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENSORS - 150 FOOT l

WIND SPEED (METERS /SECONO)

WINO.22.51.76 1.1-1.6-2.1-3.1 5.1 7.1-it.1 13.1- >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13 0 18.0 N

0 0

0 0

1 8

2 0

0 0

0 0 11 NNE O

O O

O 1

5 3

0 0

0 0

0 9

NE O

0 0

0 0 16 14 0

0 0

0 0 30 ENE 0

0 0

0 1

10 0

0 0

0 0

0 11 E

O O

O O

O 5

1 0

0 0

0 0

6 ESE 0

0 0

0 3

2 0

1 0

0 0

0 6

SE O

O O

1 1

3 2

0 0

0 0

0 7

SSE O

O 0

0 0

1 0

0 0

0 0

0 1

S 0

0 0

0 0

3 2

0 0

0 0

0 5

SSW 0

0 0

0 1

1 3

1 0

0 0

0 6

SW 0

0 0

0 2

4 0

0 0

0 0

0 6

WSW 0

0 0

0 2

9 8

0 0

0 0

0 19 W

0 0

0 0

2 29 13 0

0 0

0 0 44 WNW 0

0 0

0 0 11 4

0 0

0 0

0 15 NW 0

0 0

0 2 12 4

0 0

0 0

0 18 NNW 0

0 0

0 1

8 3

1 0

0 0

0 13 TOTAL 0 0

0 1

17 127 59 3

0 0

0 0 207 NtaMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS: 207 TOTAL HOURS FOR THE PER100:

207 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS C FROM T/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1 1.6-2.1-3.1 5.1-7.1 10.1-13.1- >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 0

2 2

3 0

0 0

0 0

7 NME O

O O

O 3

1 1

0 0

0 0

0 5

NE 0

0 0

0 2

5 2

0 0

0 0

0 9

ENE O

O O

2 1

3 2

0 0

0 0

0 8

E 0

0 0

1 0

2 2

0 0

0 0

0 5

ESE 0

0 0

1 1

2 1

0 0

0 0

0 5

SE 0

0 0

1 0

0 0

0 0

0 0

0 1

SSE 0

0 0

2 0

0 1

0 0

0 0

0 3

S 0

0 0

1 0

1 1

1 0

0 0

0 4

SSW 0

0 0

0 1

0 0

0 0

0 0

0 1

SW 0

0 0

1 1

1 2

0 0

0 0

0 5

WSW 0

0 0

1 4

3 2

0 0

0 0

0 10 W

0 0

0 1

3 15 1

0 0

0 0

0 20 WNW 0

0 0

1 1

6 3

0 0

0 0

0 11 NW 0

0 0

1 2 10 0

0 0

0 0

0 13 NNW 0

0 0

0 3

6 4

0 0

0 0

0 13 l

TOTAL 0 0

0 13 24 57 25 1

0 0

0 0 120 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMRER OF VALID HOUR $:

120 TOTAL HOURS FOR THE PERIOD:

120 t

57

River Bend Station 1997 Regulatory Guide 1.31 April 37,1998 l

l RIVER BEND STATION l

J0lN7 FREQUENCY TABLE STABILITY CLASS D 4

FROM 7/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1 1.6 2.1 3.1-5.1-7.1 10.1 13.1- >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

1 5

5 11 5

1 0

0 0

0 28 NNE 0

1 2

5 5

8 6

1 0

0 0

0

'8 NE 1

0 0

7 9

7 8

0 1

0 0

0 33 ENE 0

0 0

3 10 15 16 2

0 0

0 0 46 E

O O

5 2

4 6

9 0

0 0

0 0 26 ESE 0

0 0

0 6

9 12 0

0 0

0 0 27 SE O

0 0

5 5

5 11 0

0 0

0 0 26 SSE O

O O

4 3

4 8

0 0

0 0

0 19 s

0 0

0 2

3 2

9 0

0 0

0 0 16 SSW 0

0 0

1 2

4 9

1 0

0 0

0 17 SW 0

0 0

4 0

1 3

0 0

0 0

0 8

WSW 0

0 0

8 4

6 3

0 0

0 0

0 21 W

0 0

V 5

6 13 4

0 0

0 0

0 28 WNW 0

0 1

7 4 17 5

0 0

0 0

0 34 NW 0

1 0

5 11 17 7

1 0

0 0

0 42 NNW 0

0 4

7 9 17 19 0

0 0

0 0 56 TOTAL 1

2 13 70 86 142 134 6

1 0

0 0 455 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUM8ER OF VALID HOURS: 455 TOTAL HOURS FOR THE PERIOo: 455 RIVER BEND STATION J0lHT FREQUENCY TABLE STABILITY CLASS E FRON 7/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1 1.6-2.1-3.1 5.1-7.1 10.1-13.1 >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

1 1

5 8

4 0

0 0

0 0 19 NNE O

0 2

2 8 11 20 0

0 0

0 0 43 NE 0

0 0

4 4 13 37 0

0 0

0 0 58 ENE O

O 2

2 8 17 20 0

0 0

0 0 49 E

O O

3 7

8 20 4

0 0

0 0

0 42 ESE 0

0 0

2 3 27 24 0

0 0

0 0 56 SE O

0 0

4 5 15 15 0

0 0

0 0 39 SSE 0

0 1

2 4 11 8

0 0

0 0

0 26 S

0 0

0 0

3 17 18 0

0 0

0 0 38

$$W 0

0 0

2 1

17 11 0

0 0

0 0 31 SW 0

0 0

0 0 17 5

0 0

0 0

0 22 WSW 0

0 1

4 2 17 4

0 0

0 0

0 28 W

0 1

0 2

4 18 3

0 0

0 0

0 28 WNW 0

0 1

0 4 13 4

0 0

0 0

0 22 NW 0

0 1

0 6

7 6

0 0

0 0

0 20 NNW 0

0 0

1 3

5 7

0 0

0 0

0 16 TOTAL 0 1

12 33 68 233 190 0

0 0

0 0 537 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOUR $: 537 TOTAL HOURS FOR THE PERIOD:

537 58

River Bend Station 1997 Regalctory Ouide 1.31 April 27.1998 RIVER BEND STATION JOIN? FREQUECCY TABLE STABILITY CLASS F FROM 7/ 1/97 0:00 TO 9/30/97 23.:00 PRIMARY SENSORS 150 FOOT WINO SPEED (METERS /SECOND)

WIND.22.51

.76-1.1 1.6-2.1 3.1-5.1-7.1 10.1 13.1 >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

2 1

1 3

7 0

0 0

1 0 14 NNE 0

1 1

3 4

5 12 0

0 0

U 0 26 NE O

1 0

0 0

6 15 0

0 0

0 0 22 ENE O

O O

1 3

6 11 0

0 0

0 0 21 E

O O

1 0

4 7

1 0

0 0

0 0 13 ESE O

0 0

4 5

4 7

0 0

0 0

0 20 SE 0

1 1

2 6

7 5

0 0

0 0

0 22 SSE O

O 1

0 3

1 0

0 0

0 0

0 5

S 0

0 0

3 1

3 4

0 0

0 0

0 11 SSW 0

0 0

3 4

9 4

0 0

0 0

0 20 SW 0

0 0

1 6

4 2

0 0

0 0

0 13 WSW 0

1 0

0 6

6 0

0 0

0 0

0 13 W

0 1

0 1

0 8

1 0

0 0

0 0 11 WNW 0

0 1

1 2

8 7

0 0

0 0

0 19 NW D

0 1

3 2

8 2

0 0

0 0

0 16 NNW 0

0 0

1 3

3 2

0 0

0 0

0 9

TOTAL 0 5

8 24 50 88 80 0

0 0

0 0 255 NUM8ER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUM8ER OF VALID HOURS:

255 TOTAL HOURS FOR THE PERIOD: 255 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS G FROM 7/ 1/97 0:00 TO 9/30/97 23:00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND)

WIND

.22.

51.76 1.1-1.6 2.1-3.1 5.1-7.1 10.1-13.1- >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 a

N 0

1 0

3 2 10 11 0

0 0

0 0 27 NNE 0

0 0

4 1

7 8

0 0

0 0

0 20 NE D

0 1

2 0

5 7

0 0

0 0

15 ENE 1

0 0

0 2

3 5

0 0

0 0

t 11 E

1 0

1 3

5 5

3 0

0 0

0 0 18 ESE.

0 0

0 3

2 4

0 0

0 0

0 0

9 F.

0 0

1 3

2 3

0 0

0 0

0 0

9 SSE O

O 2

4 6

7 0

0 0

0 0

0 19 5

0 0

0 3

6 4

0 0

0 0

0 0 13 SSW 0

0 1

2 6 11 1

0 0

0 0

0 21 SW 0

0 2

0 7

8 2

0 0

0 0

0 19 WSW 0

0 0

2 4 14 0

0 0

0 0

0 20 W

0 1

2 2

2 9

3 0

0 0

0 0 19 WNW 0

0 0

3 7 19 5

0 0

0 0

0 34 NW 0

0 2

0 5 13 0

0 0

0 0

0 20 NNW 0

0 1

2 6 11 15 0

0 0

0

0 35 TOTAL 2 2

13 36 63 133 60 0

0 0

0 0 309 NUMBER OF CALMS:

0 NUM8fR OF INVALID HOUR $3 0

NUMBER OF VALID HOURS: 309 TOTAL HOURS FOR THE PERIOD:

309 59

(

EP

< ~....

River Bend Stadon 1997 Regulatoy Guide 1.21 April 37,1998 RIVER BEND STATION l

JOINT FREQUENCV TABLE l

ALL STABILITY CLASSES FROM 10/ 1/97 0:00 TO 12/31/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1-1.6 2.1 3.1-5.1-7.1 10.1-13.1 >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

8 14 11 51 55 53 36 0

0 0

0 0 228 NNE 13 12 13 38 55 38 12 1

0 0

0 0 182 NE 16 24 11 26 26 13 1

0 0

0 0

0 117 ENE 12 34 17 39 18 9

3 0

0 0

0 0 132 E

8 31 16 38 21 7

0 0

0 0

0 0 121 ESE 5

16 26 28 22 18 2

0 0

0 0

0 117 SE 1

6 12 53 58 84 30 0

0 0

0 0 244 SSE.

5 5

9 15 10 29 40 1

0 0

0 0 114 S

4 4

3 9 18 32 13 1

0 0

0 0 64 SSW 1

4 2 11 17 26 5

1 0

0 0

0 67 SW 0

1 2 12 6 10 7

0 0

0 0

0 38 WSW 1

6 4

9 15 13 3

0 0

0 0

0 51 W

6 17 11 14 10 11 7

0 0

0 0

0 76 WNW 3

16 20 31 20 28 20 3

0 0

0 0 141 NW 4 20 21 30 22 39 29 0

0 0

0 0 165 NNW 11 17 13 53 30 59 41 0

0 U

0 0 224 TOTAL 98 227 191 457 403 469 249 7

0 0

0 0 2101 NUM8ER OF CALMS:

2 NUMBER OF INVALID HOURS:

105 NUM8ER OF VALID HOURS: 2103 TOTAL HOURS FOR THE PERIOD: 2208 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS A FROM 10/ 1/97 0:00 TO 12/31/97 23:00 PRIMARY SENSORS - 30 FOOT WIMD SPEED (METERS /SECOND)

WINO.22.51

.76-1.1 1.6-2.1-3.1 5.1 7.1 10.1 13.1 >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 0

0 2 13 0

0 0

0 0 15 NNE O

O O

O 0

6 7

1 0

0 0

0 1 '.

NE O

O O

O 1

3 0

0 0

0 0

0 4

ENE O

O O

0 6

2 0

0 0

0 0

0 8

E O

O O

2 3

4 0

0 0

0 0

0 9

ESE O

O O

1 7

7 0

0 0

0 b

0 15 SE O

O 0

0 3 21 18 0

0 0

C 0 42 SSE O

0 0

0 0

8 7

0 0

0 0

0 15 S

0 0

0 0

0 2

1 0

0 0

0 0

3 SSW 0

0 0

0 1

3 0

0 0

0 0

0 4

SW 0

0 0

0 1

0 0

0 0

0 0

0 1

WSW 0

0 0

0 3

2 0

0 0

0 0

0 5

W 0

0 0

0 0

0 0

0 0

0 0

0 0

WNW 0

0 0

0 1

0 0

0 0

0 0

0 1

NW 0

0 0

0 0

1 0

0 0

0 0

0 1

NNW 0

0 0

0 0

2 6

0 0

0 0

0 8

I TOTAL 0 0

0 3 26 63 52 1

0 0

0 0 145 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMRER OF VALID HOURS:

14s TOTAL HOURS FOR THE PERIOD.

145 60

River Bend Station 1997 Regulatory Guide 1.21 April 27.1998 RIVER BEND STATION JOINT FREQUENCY TABLE STAdlLITY CLASS B FROM 10/ 1/97 0:00 TO 12/31/97 23:00 PRIMARY SENSORS - 30 FOOT WIND SPEED (METERS /SECOND)

I W!No.22.51

.76-1.1 1.6 2.1 3.1 5.1 7.1-10.1 13.1- >18 TOT.

I DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 0

1 7

9 0

0 0

0 0 17 NNE O

O O

O 1

7 0

0 0

0 0

0 8

NE O

O O

O 2

0 0

0 0

0 0

0 2

ENE s

0 0

1 1

0 0

0 0

0 0

0 2

E O

O O

1 0

2 0

0 0

0 0

0 3

ESE 0

0 0

1 4

0 0

0 0

0 0

0 5

SE O

O O

0 6

8 2

0 0

0 0

0 16 SSE O

0 0

0 0

3 10 0

0 0

0 0 13 S

0 0

0 0

0 7

5 0

0 0

0 0 12 SSW 0

0 0

1 3

1 0

0 0

0 0

0 5

SW 0

0 0

0 2

0 3

0 0

0 0

0 5

WSW 0

0 0

2 5

4 1

0 0

0 0

0 12 W

0 0

0 1

2 4

4 0

0 0

0 0 11 WNW 0

0 0

0 1

5 7

0 0

0 0

0 13 NW 0

0 0

1 1

4 14 0

0 0

0 0 20 NNW 0

0 0

0 1

5 14 0

0 0

0 0 20 TOTAL 0 0

0 8 30 57 69 0

0 0

0 0 164

)

NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

164 TOTAL HOURS FOR THE PERIOD:

164 RIVER BEND STATION JOINT FREQUENCY TAELE STABIL!iY CLASS C FROM 10/ 1/97 0:00 TO 12/31/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1-1.6 2.1-3.1 5.1-7.1-10.1 13.1- >18 TOT.

DlR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 1

1 4

1 0

0 0

0 0

7 NNE O

O 0

0 4

4 1

0 0

0 0

0 9

NE O

0 0

4 2

0 0

0 0

0 0

0 6

ENE 0

0 0

0 0

0 0

0 0

0 0

0 0

-E 0

0 0

1 6

0 0

0 0

0 0

0 7

3 ESE O

0 L

0 3

1 0

0 0

0 0

0 4

SE 0

0 0

0 1

2 1

0 0

0 0

0 4

SSE O

O 0

2.

0 1

6 0

0 0

0 0

9 S

0 0

0 0

3 1

1 0

0 0

0 0

5 SSW 0

0 0

0 1

2 0

0 0

0 0

0 3

SW 0

0 0

1 2

0 1

0 0

0 0

0 4

l WSW D

0 0

1 3

4 0

0 0

0 0

0 8

W 0

0 0

1 2

4 1

0 0

0 0

0 8

WNW D

0 0

0 0

2 4

2 0

0 0

0 8

NW 0

0 0

0 2

9 3

0 0

0 0

0 14 NNW 0

0 0

0 0

3 2

0 0

0 0

0 5

TOTAL 0

-6 0 11 50 37 21 2

0 0

0 0 101 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VA:ID HOURS:

101 TOTAL HOURS FOR THE PERIOD:

101 61

'l

{

River Bend Statica 1997 Reguictory Guide 1.31 April 27,1998 RIVER BEND STATION J0!NT FREQUENCY VA8LE STA81LliY CLASS D FROM 10/ 1/97 0:00 TO 12/31/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1-1.6-2.1 3.1 5.1-7.1-10.1-13.1- >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 I

N O

O 1

10 20 34 12 0

0 0

0 0 77 NNE O

O 0 13 32 13 3

0 0

0 0

0 61 NE O

1 0

5 14 8

0 0

0 0

0 0 28 ENE O

O 2 14 8

3 2

0 0

0 0

0 29 E

O 0

1 16 10 1

0 0

0 0

0 0 28 ESE O

1 2 12 5

7 0

0 0

0 0

0 27 SE 0

1 2 11 18 28 6

0 s

0 0

0 66 SSE O

O 1

2 2 10 15 1

0 0

0 0 31 S

0 0

0 1

5 13 2

0 0

0 0

0 21 SSW 0

0 0

3 5

9 3

1 0

0 0

0 21 SW 0

0 0

2 1

7 2

0 0

0 0

0 12 WSW 0

0 0

5 3

2 2

0 0

0 0

0 12 l

W 0

0 4

5 3

2 0

0 0

0 0 15 WNW 0

0 1

10 14 15 7

1 0

0 0

0 48 NW 0

0 1

4 12 21 12 0

0 0

0 0 50 NNW 0

1 0 14 10 46 19 0

0 0

0 0 90 TOTAL 0 4

12 126 164 220 87 3

0 0

0 0 616 NUM8ER OF CALMS:

0 NUM8ER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

616 TOTAL HOURS FOR THE PERIOD: 616 RIVER BEND STAfl0N JOINT FREQUENCY TABLE STABILITY CLASS E FROM 10/ 1/97 0:00 To 12/31/97 23:00 PRIMARY SENSORS 30 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1-1.6 2.1 3.1 5.1 7.1-10.1-13.*

>18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 5

7 22 33 6

1 0

0 0

0 0 74 NNE 0

3 4 14 17 8

1 0

0 0

0 0 47 NE 1

2 6 13 4

1 1

0 0

0 0

0 28 ENE O

1 6 14 3

4 1

0 0

0 0

0 29 q

E 0 10 8 15 2

0 0

0 0

0 0

0 35 ESE 0

6 11 12 2

3 2

0 0

0 0

0 36 SE O

2 5 38 30 24' 3

0 0

0 0

0 102 SSE O

1 4

7 7

6 2

0 0

0 0

0 27 i

S 0

1 0

4 10 9

4 1

0 0

0 0 29 SSW 0

2 1

2 7 11 2

0 0

0 0

0 25 SW 0

0 0

9 0

3 1

0 0

0 0

0 13 WSW D

3 1

0 1

1 0

0 0

0 0

0 6

y 0

1 3

3 1

0 0

0 0

0 0

0 8

WWW 0

1 3 13 4

6 2

0 0

0 0

0 29 NW 0

1 3 11 5

4 0

0 0

0 0

0 24 NNW 1

0 5 17 15 3

0 0

0 0

0 0 41 TOTAL 2 39 67 194 141 89 20 1

0 0

0 0 553 NUMBER OF CALMS:

0 NUMBEM OF INVALID HOURS:

0 NUMBER OF VALID HOUR 3:

553 TOTAL HOURS FOR THE PER100: 553 i

62

. River Band Station 1997 Regulatory Guide 1.31 April 27.1998 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS F FROM 10/ 1/97 0:00 TO 12/31/97 23:00 PRIMARY SENSORS - 30 FOOT WIND SPEED (METERS /SECONO)

WIND.22.51.76 1.1-1.6 2.1 3.1-5.1-7.1 10.1-13.1- >18 TOT.

0R

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13_0 18.0 N

1 4

3 17 0

0 0

0 0

0 0

0 25 NNE O

2 8 11 1

0 0

0 0

0 0

0 22 NE 1

3 3

4 3

1 0

0 0

0 0.

0 15 ENE 2

5 5

8 0

0 0

0 0

0 0

0 20 E

1 7

6 3'

0 0-0 0

0 0

0 0 17 ESE 1

7 11 2

1 0

0 0

0 0

0 0 22 SE O

2 4

3 0

1 0

0 0

0 0

0 10

$$E O

2 1

2 1

1 0

0 0

0 0

0 7

S 1

1 2

4 0

0 0

0 0

0 0

0 8

SSW 0

0 1

4 0

0 0

0 0

0 0

0 5

SW 0

0 1

0 0

0 0

0 0

0 0

0 1

WSW 0

1 2

1 0

0 0

0 0

0 0

0 4

W 0

4 3

4 0

0 0

0 0

0 0

0 11 WNW 1

2 5

6 0

0 0

0 0

0 0

0 14 NW 0

4 7 11 2

0 0

0 0

0 0

0 24 NNW 0

2 5 15 4

0 0

0 0

0 0

0 26 TOTAL 8 46 67 95 12 3

0 0

0 0

0 0 231 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOUR $t 231 TOTAL HOURS FOR THE PERIOD:

231 RIVER BEND STATION JOINT FREQUENCY TABLE STABILITY CLASS G FROM 10/ 1/97 0:00 TO 12/31/97 23:00 PRIMARY SENSORS - 30 FOOT 1

WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1-1.6 2.1-3.1-5.1 7.1 10.1-13.1 >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

7 5

0 1

0 0

0 0

0 0

0 0 13 NNE 13 7

1 0

0 0

0 0

0 0

0 0 21 NE 14 18 2

0 0

0 0

0 0

0 0

0 34 ENE 10 28 4

2 0

0 0

0 0

0 0

0 44 E

7 14 1

0 0

0 0

0 0

0 0

0 22 ESE 4

2 2

0 0

0 0

0 0

0 0

0 8

SE 1

1 1

1 0

0 0

0 0

0 0

0 4

SSE 5

2 3

2 0

0 0

0 0

0 0

0 12 S

3 2

1 0

0 0

0 0

0 0

0 0

6 SSW 1.

2 0

1 0

0 0

0 0

0 0

0 4

SW 0

1 1

0 0

0 0

0 0

0 0

0 2

WW 1

2 1

0 0

0 0

0 0

0 0

0 4

W 6 12 4

1 0

0 0

0 0

0 0

0 23 WWW 2 13 11 2

0 0

0 0

0 0

0 0 28 NW 4 15 10 3

0 0

0 0

0 0

0 0 32 NNW 10 14 3

7 0

0 0

0 0

0 0

0 34 TOTAL 88 138 45 20 0

0 0

0 0

0 0

0 291 NUMBER OF CALMS:

2 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

293 TOTAL HOURS FOR THE PERIOD 293 63

i River Bend Station 1997 Regubory Guide 1.31 April 27,1998 l

RIVER SEND STATICN JOINT FREQUENCY TABLE ALL STABILITY CLASSES 1

FROM 10/ 1/97 0:00 TO 12/31/97 23:00 PRIMARY SENSORS

  • 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51.76 1.1-1.6-2.1-3.1 5.1 7.1-10.1-13.1- >18 TOT.

D1R

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 4

7 49 130 16 0

0 0

0 206 NNE 0

0 0

6 7 62 79 13 5

0 0

0 1 72 NE O

1 1

6 10 34 86 10 1

0 0

0 149 ENE 0

2 2 10 14 44 83 12 3

0 0

0 170 l

E 0

0 1

3 8 40 61 2

1 0

0 0 116 I

ESE O

O 3

7 8 31 152 60 10 0

0 0 271 SC 0

0 1

6 7 26 80 38 0

0 0

0 158 SSE O

O 1

1 7 26 18 15 1

0 0

0 69 s

0 0

2 3

6 31 42 8

1 0

0 0 93

)

SSW 0

1 2

5 7 24 33 6

0 0

0 0 78 j

SW 0

1 1

3 9 20 20 6

0 0

0 0 60 j

WSW 0

0 1

2 8 30 19 7

0 0

0 0 67 j

W 0

0 0

2 7 31 38 11 1

0 0

0 90 WNW 0

0 1

1 7 41 55 17 5

0 0

0 127 NW 0

0 0

3 4 33 79 13 0

0 0

0 132 NNW 0

0 0

1 5 28 91 20 0

0 0

0 145 TOTAL 0 5

16 63 121 553 1066 254 28 0

0 0 2103 l

NUMBER OF CALMS:

0 NUM8ER OF INVAllD HOURS:

105 f

NUMBER OF VALID HOURS: 2103 TOTAL HOURS FOR THE PERIOD: 2208 l

i I

l I

RIVTR BEND STATION i

JOINT FREQUENCY TABLE STABILITY CLASS A FROM 10/ 1/97 0:00 70 12/31/97 23:00 PRIMARY SENSORS - 150 FOOT l

l WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1-1.6-2.1 3.1 5.1-7.1 10.1 13.1- >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 0

0 0

6 6

0 0

0 0 12 NNE 0

0 0

0 0

0 3

7 4

0 0

0 14 NE O

O O

O 0

2 5

0 1

0 0

0 8

ENE O

O

'O O

1 5

7 0

0 0

0 0 13 E

O O

O O

O 5

6 1

0 0

0 0 12 ESE 0

0 0

0 0

4 18 15 0

0 0

0 37 SE O

0 0

0 0

3 9 13 0

0 0

0 25 SSE D

0 0

0 0

2 1

0 0

0 0

0 3

S 0

0 0

0 0

1 1

1 0

0 0

0 3

SSW 0

0 0

0 0

1 3

0 0

0 0

0 4

SW 0

0 0

0 0

2 0

0 0

0 0

0 2

WSW D

0 0

0 0

2 2

0 0

0 0

0 4

W 0

0 0

0 0

0 0

0 0

0 0

0 0

WWW 0

0 0

0 0

1 0

0 0

0 0

0 1

NW 0

0 0

0 0

0 1

1 0

0 0

0 2

NNW 0

0 0

0 0

0 1

4 0

0 0

0 5

TOTAL 0 0

0 0

1 28 63 48 5

0 0

0 145 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

145 TOTAL HOURS FOR THE PERIOD:

145 l

64

i l

River Bend Station 1997 Rzgula:ory Guide 1.2I April 27,1998 RIVER SEND STATION i

JOINT FREQUE%CY TABLE STA8ILITY CLASS B FROM 10/ 1/97 0:00 TO 12/31/97 23:00 l

PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND) i i

WIND.22.51.76 1.1 1.6 2.1 3.1 5.1 7.1 10.1 13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 O

O O

1 2 10 4

'0 0

0 0 17

)

NNE O

O O

O 1

2 5

0 1

0 0

0 9

1 NE 0

0 0

0 0

3 1

0 0

0 0

0 4

ENE O

O O

0 2

1 0

0 0

0 0

0 3

E O

O O

O O

O 3

0 0

0 0

0 3

ESE O

O O

1 0

2 11 0

0 0

0 0 14 j

SE O

O O

O 0

1 6

4 0

0 0

0 11 SSE O

0 0

0 0

0 1

9 0

6 0

0 10 0

0 0

0 0

3 5

1 0

0 0

0 9

SSW 0

0 0

1 1

3 1

0 0

0 0

0 6

SW 0

0 0

0 1

2 0

3 0

0 0

0 6

WSW 0

0 0

1 0

6 3

2 0

0 0

0 12 W

0 0

0 0

3 2

4 1-1 0

0 0 11 WNW 0

0 0

0 0

2 5

7 0

0 0

0 14 NW 0

0 0

0 0

3 9

7 0

0 0

0 19 NNW 0

0 0

0 1

0 11 4

0 0

0 0 16 I

(

TOTAL 0 0

0 3 10 32 75 42 2

0 0

0 164 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOUR $:

144 TOTAL HOURS FOR THE PER100:

164 i

RIVER BEND STATION j

JOINT FREDUENCY TABLE STABILITY CLASS C FROM 10/ 1/07 0:00 TO 12/31/97 23:00

)

PRIMARY SENSCRS 150 FOOT WIND SPEED (METERS /SECOND)

WIND.22.51

.76-1.1 1.6 2.1 3.1-5.1-7.1-10.1-13.1 >18 TGT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 O

O O

1 1

2 0

0 0

0 0

4 NN5 0

0 0

0 1

4 5

1 0

0 0

0 11 NE 0

0 0

0 3

3 1

0 0

0 0

0 7

ENE 0

0 0

0 0

0 1

0 0

0 0

0 1

E O

O O

O O

O 5

0 0

0 0

0 5

ESE O

O 0

1 0

2 4

1 0

0 0

0 8

SE 0

0 0

1 1

0 0

5 0

0 0

0 7

SSE 0

0 0

0 0

0 1

1 0

0 0

0 2

S 0

0 0

0 1

3 1

1 0

0 0

0 6

SSW 0

0 0

1 0

2 1

0 0

0 0

0 4

SW 0

0 0

0 1

0 1

0 0

0 0

0 2

WSW 0

0 0

0 1

8 1

1 0

0 0

0 11 W

0 0

0 0

0 4

1 0

0 0

0 0

5 WNW D

0 0

0 0 -- 1 5

2 3

0 0

0 11 NW 0

0 0

0 1

3 8

0 0

0 0

0 12 NNW 0

0 0

0 0

1 3

1 0

0 0

0 5

TOTU.

0 0

0 3 10 32 40 13 3

0 0

0 101 NUMBER OF CALMS:

0 i

NUMBER OF INVALID HOURS:

0 l

NUMBER OF VALID HOURS:

101 TOTAL HOURS FOR THE PERIOD:

101 65

River Bend Static 1997 Regulatory Guide 1.21 April 27.1998 RIVER BEND STATION J0!NV FREQUENCY TABLE STABILITY CLASS D FROM 10/ 1/97 0:00 TO 12/31/97 23.00 PRIMARY SENSORS - 150 FOOT WIND SPEED (METERS /SECOND) l WIND.22.51

.76-1.1-1.6-2.1-3.1 5.1-7.1-10.1-13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 1

4 18 35 6

0 0

0 3 64 NNE O

O O

2 3 19 23 3

0 0

0 0 50 NE O

0 0

1 2 11 36 4

0 0

0 0 54 ENE O

O O

3 3

6 17 2

2 0

0 0 33 E

O 0

0 1

2 11 21 1

1 0

0 0 37 ESE O

O 1

4 2

4 29 20 4

0 0

0 64 SE 0

0 0

1 3

6 11 10 0

0 0

0 31 SSE 0

0 1

0 0

3 7

5 1

0 0

0 17 S

0 0

1 1

1 4

13 2

0 0

0 0 22 CSW 0

0 1

0 1

6 9

3 0

0 0

0 20 SW 0

0 0

1 3

3 9

2 0

0 0

0 18 WSW 0

0 0

0 4

1 4

3 0

0 0

0 12 W

0 0

0 0

2 6

6 9

0 0

0 0 25 WNW 0

0 0

1 4 15 17 6

2 0

0 0 45 NW 0

0 0

1 2

9 33 4

0 0

0 0 49 NNW 0

0 0

1 4

16-44 10 0

0 0

0 75 TOTAL 0 0

4 20 40 138 314 90 10 0

0 0 616 NJM8ER OF CALMS:

0 1

WUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

616 TOTAL HOURS FOR THE PERIOD: 616 Rl"ER BEND STATION J0!NT FREQUENCY TABLE STABILITY CLASS E i

FROM 10/ 1/97 0:00 TO 12/31/97 23:00 PRIMARY SENSORS - 150 FOOT WIN 0 SPEED (METERS /SECOND)

WIND.22.51

.76-1.1-1.6 2.1 3.1-5.1 7.1 10.1 13.1- >18 TOT.

DIR

.50. 75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

O O

O 2

0 21 42 0

0 0

0 0 65 NNE O

O O

1 1

15 31 2

0 0

0 0 50 hE O

0 1

3 4

8 18 3

0 0

0 0 37 ENE 0

0 0

4 6 13 26 7

1 0

0 0 57 E

D 0

0 1

4 13 19 0

0 0

0 0 37 ESE O

O O

O 1

9 60 21 6

0 0

0 97 SE 0

0 0

0 1

7 26 6

0 0

0 0 40 SSE O

O O

1 1

7 3

0 0

0 0

0 12 S

0 0

1 1

0 6 13 3

1 0

0 0 25 SSW 0

0 0

1 0

7 15 3

0 0

0 0 26 SL 0

1 0

1 0

6 7

1 0

0 0

0 16 WSW D

0 0

0 1

5 2

1 0

0 0

0 9

W 0

0 0

0 0

4 14 1

0 0

0 0 19 WWW 0

0 1

0 0

7 4

2 0

0 0

0 14 NW 0

0 0

2 0

6 12 1

0 0

0 0 21 NNW 0

0 0

0 0

6 21 1

0 0

0 0 28 TOTAL 0 1

3 17 19 140 313 52 8

0 0

0 553 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS:

553 TOTAL HOURS FOR THE PERIOD: 553 66

k.iver Bend Station 1997 Regulate / Ouide 1.21 April 27.1998 RIVER BENO STATION JOINV FREQUENCY TABLE STABILITY CLASS F FROM 10/ 1/v7 0:00 TO 12/31/97 23:00 PRIMARY SENSORS - 150 Fe3T WIND SPEED (METERS /SECONi)

WIND.22.51

.76-1.1 1.6-2.1-3.1 5.1-7.1 10.1-13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 1

0 4 26 0

0 0

0 0 31 NNE 0

0 0

0 1

9 9

0 0

0 0

0 19 l

NE O

0 0

0 0

2 15 3

0 0

0 0 20 i

ENE O

0 0

1 0 13 13 3

0 0

0 0 30 E

O O

O 1

2 5

2 0

0 0

0 0 10 ESE 0

0 0

0 0

5 20 3

0 0

0 0 28 SE 0

0 0

0 1

4 14 0

0 0

0 0 19 SSE 0

0 0

0 1

3 3

0 0

0 0

0 7

S 0

0 0

1 0

2 5

0 0

0 0

0 8

SSW 0

0 0

0 1

2 2

0 0

0 0

0 5

SW 0

0 0

0 0

2 1

0 0

0 0

0 3

WW 0

0 0

0 0

3 2

0 0

0 0

0 5

W 0

0 0

0 0

5 3

0 0

0 0

0 8

WNW 0

0 0

0

.0 5 11 0

0 0

0 0 16 NW 0

0 0

0 0

6 6

0 0

0 0

0 12 NNW 0

0 0

0 0

1 9

0 0

0 0

0 10 TOTAL 0 0

0 4

6 71 141 9

0 0

0 0 231 NUMBER OF CALMS:

0 NUMBER OF INVALID HOURS:

0 NUM8ER OF VALID HOURS: 231 TOTAL HOURS FOR THE PER100: 231 RIVER BFND STATION JOINT FREQUCdCY TABLE STABILITY CLASS G FROM 10/ 1/97 0:00 TO 12/31/97 23:00 PRIMARY SENSORS - 150 FOOT WINO SPEE0 (METERS /SECONO)

WINO.22.51.76 1.1 1.6-2.1 3.1 5.1 7.1 10.1 13.1 >18 TOT.

DIR

.50.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 N

0 0

0 0

1 3

9 0

0 0

0 0 13 1

NNE 0

0 0

3 0 13 3

0 0

0 0

0 19 l

NE O

1 0

2 1

5 10 0

0 0

0 0 19 l

ENE O

2 2

2 2

6 19 0

0 0

0 0 33 E

0 0

1 0

0 6

5 0

0 0

0 0 12 ESE O

O 2

1 5

5 10 0

0 0

0 0 23 SE O

0 1

4 1

5 14 0

0 0

0 0 25 SSE 0

0 0

0 5 11 2

0 0

0 0

0 18 S

0 0

0 0

4 12 4

0 0

0 0

0 20 SSW 0

1 1

2 4

3 2

0 0

0 0

0 13 SW 0

0 1

4 5

2 0

0 0

0 0 13 WSU C

0 1

1 2

5 5

0 0

0 0

0 14 W

0 0

0 0

2 10 10 0

0 0

0 0 22 WNW 0

0 0

0 3

10 13 0

0 0

0 0 26 NW 0

0 0

0 1

6 10 0

0 0

0 0 17 NNW 0

0 0

0 0

4 2

0 0

0 0

0 6

j TOTAL 0 4

9 16 35 109 120 0

0 0

0 0 293 NUMBER OF CALMS:

0 WUPtBER OF INVALID HOURS:

0 NUMBER OF VALID HOURS: 293 TOTAL HOURS FOR THE PER100: 293 67 l

l J

River Iknd Stdion 1997 Regulatory Guide 1.31 April 27,1998 l

TABLE 14 ATMOSPIIERIC DISPERSION FAC70RS (X/Q FACTORS) (D/Q FACTORS) 1997 68

m' River Hend Static 1997 Rcgulatory Guide 1.21 April 37,1998 4

Table 14 ATMOSPHERIC DISPERSION AND DEPOSITION RATES FOR THE MAXIMUM INDIVIDUAL DOSE CALCULATIONS Analysis Location Ground Level Mixed Mode (meters)

Releases Releases Gamma air dose (3) and 994 m WNW (Containment)

CHUQ - 421.0 CHUQ - 33.1 Beta Air Dose Maximum Receptor

' 994 m WNW CHUQ - 421.0 CHUQ - 33.1 Resident D/Q - 50.3 D/Q - 18.1 Garden l

Meat animal 1

Immersion Milk animal 7,000 m WNW CHUQ - 3.58 CHI /Q

.870 D/Q - 0.38 D 'Q

.223 Other on-site Receptors 115 m ENE CHI /Q - 5977.0 CHI /Q - 407.5 (6)

D/Q - 529.7 D/Q - 46.9 275 m N CHUQ - 1644.0 CHI /Q - 169.1 D/Q - 345.6 D/Q - 68.4 500 WNW CHUQ - 916.7 CHUQ - 105.4 j

D/Q - 148.1 D/Q - 45.6 l

2500 SW CHUQ - 34.45 CHI /Q - 4.65 D/Q - 3.35 D/Q - 1.40 Notes:

(1) All CHI /Q = 10-7 sec/m3 (2) All D/Q = 10-9 m-2 k

l (3) Maximum offsite location (property boundary) with highest CHUQ (unoccupied).

(4) Maximum hypothetical occupied offsite location with highest CHUQ and D/Q.

(5) No milk animal within 5 miles radius, hypothetical location in worst sector.

l (6) Other on-site receptors.

l l

1 l

t 69