ML20035A899

From kanterella
Jump to navigation Jump to search
Responds to Allegations That I&C Technicians Required to Work Excessive Hours in Support of Facility Startup on 910217 & That Technician Insufficiently Trained on Surveillance Procedure.Util Response to Concerns Encl
ML20035A899
Person / Time
Site: Millstone 
Issue date: 07/22/1991
From: Wenzinger E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
AFFILIATION NOT ASSIGNED
Shared Package
ML20035A875 List:
References
FOIA-92-162 NUDOCS 9303300182
Download: ML20035A899 (1)


Text

LOCT[04 'L91.08f47' NRC MILLSTONE OFFICE' P06 1

  • 1 S

UNITr0 STATts

.{

NUCt. EAR REGULATORY COMMISSION i

REGION I h

L e,

475 ALLENoALE RoAo g,gg WG oF FRUsslA, PENNsYLVAN'A tN14tg

.j JUL

  • 21991

)

i

)

k ii This letter refers to several h

concerns t at you provided to us, the first set on March 2,1991, alleged that I&C.

4 technicians were required to work excessive hours in support of the Unit 2 startup on i

February 17_,1991, and that a technician was insufficiently trained on a surveillance procedure. Your second.concem, on March 5,1991, alleged that the procedures used to '

calibrate the replacement feedwater and charging flow transmitters were not appropriate for

- use with the newer Foxboro "sraart" transmitters.

These concerns were referred to the licensee for their evaluation. Attached for your information are their responses to these concerns. ne licensee has made changes to improve the procedure review process and the on-the-job training program to address'your concern-about technician training when procedures undergo significint change. De licensee also i

plans additional training for I&C technicians in the calib: 7 tion process for the "sman" 1

transmitters. 7he other concerns were not substantiated.

The NRC plans no further action in any of these matters. Please advise us if you wish to' pursue further any of these issues. Thank you for informing us of your concerns.

[

t i

Sin ly, l

l a

h ward Wenzinger, Ch'.

Reactor Projects Brant

i

Enclosures:

1. NU letter A09557, dated 7/1/91
2. NU letter A09558, dated 7/1/91 j

i 9303300182 921104 l

PDR FOIA HUBBARD92-162 PDR d

ii

}

1]

x

..