05000325/LER-1982-118-03, /03L-0:on 821026,RTGB Narrow & wide-range Instruments Showed Suppression Pool Level of -29 Inches While Actual Level -26.5 Inches.Caused by Instrumentation Inaccuracies.Instrumentation Recalibr & Pool Level Restored

From kanterella
(Redirected from ML20028B823)
Jump to navigation Jump to search
/03L-0:on 821026,RTGB Narrow & wide-range Instruments Showed Suppression Pool Level of -29 Inches While Actual Level -26.5 Inches.Caused by Instrumentation Inaccuracies.Instrumentation Recalibr & Pool Level Restored
ML20028B823
Person / Time
Site: Brunswick 
Issue date: 11/24/1982
From: Pastva M
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20028B821 List:
References
LER-82-118-03L-01, LER-82-118-3L-1, NUDOCS 8212070012
Download: ML20028B823 (1)


LER-1982-118, /03L-0:on 821026,RTGB Narrow & wide-range Instruments Showed Suppression Pool Level of -29 Inches While Actual Level -26.5 Inches.Caused by Instrumentation Inaccuracies.Instrumentation Recalibr & Pool Level Restored
Event date:
Report date:
3251982118R03 - NRC Website

text

NRC FORM 366 U. S. NUCLEAR REGULATCRY COMMISSION (111V. )

W-LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

l 0 l 1 l l Nl C l B l E l P l 1 l@l 0 l 0 l - l 0 l 0 l 0 l 0 l 0 l - l 0 l 0 l@l 4 l 1 l 1 l 1 l 1 lhl l

l@

7 8 9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE JO 57 CAT 58 CON'T l0l11 l L @l 0l 5 l 0 l - l 0 l 3 l 2 l 5 l@l 1 l 0 l 2 l 6 l 8 l 2 @l 1l 1 l 2 l 4 l 8 l 2 l@

REPO 3 ug 7

8 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h 10121 l During plant operation. performance of the Suporession Pool Level Indicators Oper-I l o l 3 l l ability Test revealed that the RTGB narrow and wide range instruments showed a pool l

l o l 4 l l level of -29" while the actual level was -26.5".

The specified operating range for l

lo ls] l suppression chamber water level is -27" to -31".

This event did not affect the health l 0 6 l and safety of the public. The inoperability of the subiect_RTGB instrumentation is l

10171 l being reported in LER 1-82-117.

l 101811 Technical Specifications 3.6.2.1, 6.9.1.9b l

80 7

8 9 C DE CODE S BC E COMPONENT CODE SUB dE SU E

l S l Hlh Wh Wh l Il Nl Sl Tl Rl Ulh [_T_jh W h O 9 7

8 9

10 11 12 13 18 19 20 SEoVENTIAL OCCURRENCE REPORT REVISION LE R/Ro EVENT YE AR REPORT NO.

CODE TYPE N O.

h Rtg l8 l2 l

[---J l1 l1 l8 l l/l l 01 3 l W

l-l W

yu

,, 21 22 23 24 26 27 28 29 30 31 32 K N ATO ON L NT E

HOURS 22 S8 IT D FOR B.

SU L1 R MANUF CTURER [XJg W g W g y @

l0 l0 l0 l0 l WQ {@

{@

lR l3 l6 l9 l@

33,_

34 3S 36 3/

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h lThe level went out of specification without operator knowledge due to the inaccuracies l i O li li l l in the subject level instrumentation. The instrumentation was recalibrated and I

l suppression pool level was restored to normal. This level instrumentation will be I

i 7 l modified for each unit to provide more reliable indicatioa. A similar event was l

i 3 [i l4 ] l reported in LER 2-82-74.

I 80 7

8 9 SIA S

% POWE R OTHER STATUS OSCO RY DISCOVERY DESCRIPTION NA l l B l@l Periodic Test l

l1 lsl W@ l0 l 6 l 5 l@l A TiVITY CO TENT RELEASED oF RELE ASE AMOUNT OF ACTIVITY LOCATION OF RELEASE NA l l

NA l

W @ [Z,j@l 1 6 7

8 9 to 11 44 45 80 PERSONNEL E XPoSURES NUMBER TYPE

DESCRIPTION

[ 0 l 0 l 0 l@l Z l@l NA l

1 7

,ERSONd'iN,uLS DESCRIPTION @

NuvsER NA l

l0l0l0l@l l

i R i

7 8 3 11 12 80 LOSS OF OR DAMAGE To FACILt TY TYPE

DESCRIPTION

NA l

W @l

9 80 1

8 9 10 g2 2070012 821124 PUBL ICITY NRC USE ONLY pDR ADOCK 05000325 issVEo@ DESCRIPTION IA I

IIIIIIIIIIIIII W

l S

PDR 2 o 7

8 9 10 68 69 80 5 NAME OF PREPARER PHONE:

~