LER 81-013/03L-0:on 810528,during Testing of Station Battery Rated Load Test W/Plant in Cold shutdown,125 Volt Batteries 1A & 1B Discharged at Rate Greater than Required.Caused by Error in Reading Procedure.Procedure Will Be Revised
ML20009F046
Person / Time
Site: Cooper Entergy icon.png
Issue date: 06/24/1981
From: Lawrence L
NEBRASKA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20009F041 List:
References
LER-81-013-03L, LER-81-13-3L, NUDOCS 8107280629
Download: ML20009F046 (1)


Text

_, . . .

,..n-NRC F ORM 356 U. S. NUCLE AR REGUL AToRY COMMISSION f 7 !!D LICENSEE EVENT REPORT CONTHOL BLOCK: l l l l l l l (PLE ASE PRINT OR YYPE ALL REoutRED INFoRMATioNI i o l o l 8i l9 IN l LICENSEEE l C CODE l P l R14l 1 15l@l 0 10 l - dCENSE ] 0 l 0NUMBER l 0 l 0 l - l 0 l 250 l 02ti l@lLICENSE 4 l 1TYPE l 1JOl 1l S1l@l l t CA I $8 l@

7 CON'T 7

o i 8

3$n"E60 lL @l0 61 l 510 l 010 l 2 l 918 OOCKET NUMBER 58

@[0151218181 69 EVENT DATE I l@l OlREPORT 74 76 E l 2l 418 80l 1 l@

DATE EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h l 0 l 2 l IWhile performing Surveillance Procedure 6.3.15.2, Station Battery Rated Load Test, j i

l 0 ,3 ; lduring cold shutdown, 125V batteries 1A and 1B were discharged at a rate greater l o 14 I lthan required. The final specific gravity readings for batteries 125V 1A,1B, &

l

[ o I s 1 @50V 1B were not properly taken and recorded. Redundant batteries were available.

l 10161l l

0 7 l I

10181l 80 SYSTEM CAUSE CAUSE COVP. VALVE CODE CODE SUSCODE COMPONENT CODE SU8 CODE SUBCODE O 9 8 9 l v l c lO l.AJ@ LcJ@ In l^ l r ir i a l v i@ WG W @

IO 93 92 13 18 19 20

/

OCCUR RE NCE REPORT REVISION SE QUE N TI AL Rt"JR T NO. CODE TYPE NO.

EVENTVEAR

@ ag,Ro LE R l8 l ll [--J l Ol 11 3l [g_] l 013 l 29 y

30

[---J 31

[0_j 32 i

,,_ 21 22 23 24 26 27 28 ON PL T ET HOURS 22 SB IT FOR b 8. SUPPL R MANUFACTUR R TAKEN A TO y@lH l@ [Z_j@ lZj@ l0 l0 l0 l0 40l @@

31 41 U g 42 lX 43 l@ [44El 3l 5 ( 547l@

JJ J4 35 M CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h I t 10 l l Personnel error in reading procedure. Hydrometer used to take specific gravity l i

l i l i i Ireadines af ter discharee was not of proper rance to register readines. Procedure l

1 i 121 [will be revis(d and will include a QC check of the test. Hydrometers of the proper I

lijall range are being procured.

I li i41 l 80 7 8 9 i  % POWE R OTHER STATUS 015 OV RY DISCOVERY 0ESCRIP1 TON STA s I 1 5 (Sj@ l0l0l0l@l NA l [_Bj@l Engineer Observation l ACTIV.Ty CO TENT AMOUNT OF ACTIVtTY LOCATION OF RELEASE RELE ASED OF.RELE ASE 7

1 6 8 9 h 10 hl 31 NA 44 l l 45 NA 80 l

PERSONNEL EXPOSURES NUMBE R TYPE DESCRIPTION l

I t l 71 l 0 ] 0 l'O l@L7J@l NA PERsONNEi tNJU IES NUunER DESCRiPriONh l 1 a H

l010l0!@l

  • s 11 12 NA 80 t USS OF Of t DAMAGE TO F ACILITY
  • TvPE DE sclaiP TION 1

1 9 (,2]@l NA 8 810728062905000298 810624 WW* .

. Poni IIrv 2 o c..o,n@oe.o LnJ l NA iPnouk S PDR ADOCK PDR l 68 69 lllllllllllll7 80 5 i n 9 to o

L. I. Lawrence PHONE- ENCNi l $

NAVE OF P54EPARER