Other: ML19338D069, ML19338D073, ML19338F796, ML19338F800, ML19340B623, ML19340B933, ML19340C062, ML19345B102, ML20002B327, ML20003E180, ML20010G148, ML20037D564, ML20041B812, ML20054L849, ML20094B833, ML20099D014, ML20101Q590, ML20108D862, ML20112H308, ML20125E193, ML20126J293, ML20126L925, ML20137E998, ML20137T681, ML20141M903
|
MONTHYEARML19338D0691980-08-29029 August 1980 Forwards Order Requiring Info Supporting Environ Qualification of safety-related Electrical Equipment. Requests Submittal of Info by 801101 Project stage: Other ML19338D0731980-08-29029 August 1980 Order for Mod of License DPR-54 to Add Info Which Fully Responds to NRC Request for Info Re Environ Qualification of safety-related Electrical Equipment.Info Should Be Submitted by 801101 Project stage: Other ML19338F7961980-09-19019 September 1980 Forwards Revised Order for Mod of License Which Requires Submission of Info to Support Environ Qualification of safety-related Electrical Equipment Project stage: Other ML19338F8001980-09-19019 September 1980 Revised Order for Mod of License Requiring Timely Submission of Info Previously Requested Re Environ Qualification of safety-related Electrical Equipment Project stage: Other ML19340B6231980-10-24024 October 1980 Revised Tech Spec Pages Per 801024 Order for Mod of License Re Environ Qualification of safety-related Electrical Equipment Project stage: Other ML19340C0621980-10-31031 October 1980 Forwards Final Response to IE Bulletin 79-01B & Suppls 1-3, Environ Qualification of Class IE Equipment. All Outstanding Items Identified Will Be Reviewed by 820630 Project stage: Other ML19340B9331980-11-0505 November 1980 RO 80-44:providing Addl Info on Inability to Obtain Qualification Documentation for Meletron Pressure Switches. Review Concluded Two Credible Failure Modes,Short & Ground, Would Not Produce Malfunction.Interim Operation Justified Project stage: Other ML19345B1021980-11-12012 November 1980 Forwards Response to IE Bulletin 79-01B, Environ Qualification of Class IE Equipment Project stage: Other ML20002B3271980-12-0505 December 1980 Requests,On Behalf of Util,Extension Until 810108 to Request Hearing Re NRC 801118 Order for Mod to License.Requested Extension Would Allow for Better Understanding of Order Requirements Project stage: Other ML20126L9251980-12-15015 December 1980 Technical Evaluation Rept, Environ Qualification of Safety- Related Electrical Equipment to Harsh Environs Project stage: Other ML19347D4811981-03-17017 March 1981 Forwards Preliminary Results of NRC Review of Environ Qualification of safety-related Electrical Equipment at Facility.Identified Deficiencies & Ramifications Should Be Reviewed & Overall Findings Submitted Project stage: Approval ML20003E1801981-03-27027 March 1981 Advises of Safe Operation of Facility Re Equipment Function, Qualification & Environ Conditions for Electrical Equipment, Per Conditions Identified in 801031 Response to IE Bulletin 79-01B,in Response to NRC Project stage: Other ML18086B7001981-05-29029 May 1981 Forwards Safety Evaluation Re Environ Qualification of safety-related Electrical Equipment & Technical Evaluation Rept, Environ Qualification of Safety-Related Electrical Equipment to Harsh Environs Project stage: Approval ML20126L9191981-05-29029 May 1981 Safety Evaluation Re Environ Qualification of safety-related Electrical Equipment.No Outstanding Items Requiring Immediate Corrective Action.Completion of Corrective Actions by 820630 Will Ensure Compliance W/Nrc 800523 Memorandum Project stage: Approval ML20004F9921981-06-12012 June 1981 Requests Notification within 90 Days of Receipt of Safety Evaluation Re Intention to Pursue Hearing Request Project stage: Approval ML20037D5641981-08-14014 August 1981 Informs of NRC 810731 Recommendation to Extend 820630 Deadline for Hearing Re Environ Qualification of safety- Related Equipment to 830630 W/Limited Provisions for Further Extensions.Response Requested by 810901 Project stage: Other ML20010E6161981-09-0101 September 1981 Affirms NRC Proposing That Util Request for Extension of Time to Request Hearing Be Held in Abeyance for Up to 30 Days After Commission Has Completed Action on Petition to Extend 820630 Deadline for Environ Actions Project stage: Request ML20010G1481981-09-0808 September 1981 Forwards Info Re Environ Qualification of safety-related Electrical Equipment,In Response to NRC .Sys Component Evaluation Worksheets Revised by Encl Info Will Be Submitted by 811101 Project stage: Other ML20039B7301981-12-21021 December 1981 Request for Addl Info Re Equipment Environ Qualification Review of Licensees Resolution of Outstanding Issues from NRC Equipment Environ Qualification Safety Evaluation Repts & TMI Action Plan Installed Equipment Project stage: Request ML20041B8121982-02-17017 February 1982 Responds to NRC Requesting Info Re Pipe Breaks Outside Containment.Calculations for Determining Temp Profiles Encl.Util Not Aware of Beta Attenuation Calculation,However,Beta Dose Calculation Has Been Included Project stage: Other ML20054L8491982-07-0101 July 1982 Forwards Current Schedule for Installation of Qualified Electrical Equipment.Evaluation Worksheets & Test Repts Have Not Been Sent for Item II.D.3, Valve Position Indication, Since Five of Six Units Tested Failed Project stage: Other ML20085J3351983-10-10010 October 1983 Discusses 831013 Meeting to Resolve Deficiencies Noted in Franklin Research Ctr Technical Evaluation Rept Re Environ Qualification of safety-related Electrical Equipment.Agenda & Supporting Documentation Encl Project stage: Meeting ML19306E5041984-03-23023 March 1984 Notification of 840516 Meeting W/Util in Bethesda,Md to Discuss & Resolve All Outstanding Equipment Environ Qualification Issues for Facility.List of Attendees & Viewgraphs Encl Project stage: Meeting ML20094B8331984-08-0202 August 1984 Requests Extension of Qualification Program Completion Schedule to End of June 1985 Refueling Outage for Crosby Lift Indicating Switch Assemblies & Veam Thermocouple Connectors Project stage: Other ML20099D0141984-10-30030 October 1984 Notice of Environ Assessment & Finding of No Significant Impact Re 840802 Request for Extension of Deadline for Final Environ Qualification of Certain Electrical Equipment Important to Safety Project stage: Other ML20099D9351984-11-15015 November 1984 Submits Addl Info Re 841109 Tech Spec Change Request 102 Concerning Overpower & Overtemp Delta Temp Compensation Project stage: Request ML20101A2221984-12-13013 December 1984 Forwards Manufacturer Response Time Test Results to Suppl Info Provided in Re Overtemp & Overtemp delta-T Lag Compensation Project stage: Request ML20101Q5901984-12-28028 December 1984 Forwards Fee for Extension of Deadline for 840802 Environ Qualifications Per .Fee Paid Project stage: Other ML20108D8621985-03-0101 March 1985 Requests Further Extension of 850331 outage-based Equipment Qualification Deadline for Hydrogen/Oxygen Analyzers.Revised Schedule for Completion of Qualification Testing on Hydrogen/Oxygen Analyzers Encl Project stage: Other ML20112H3081985-03-27027 March 1985 Requests Expedited Relief from Current 850331 Equipment Qualification Deadline for Facility Drywell & Oxygen Analyzers Until 851130 Due to Recent Change in Schedule for Upcoming Refueling Outage Project stage: Other ML20112H1641985-03-28028 March 1985 Forwards Rev 2 to Inservice Testing Program,Point Beach Nuclear Plant Units 1 & 2, as Part of Pump Relief Request 9.Requests That NRC Grant Interim Approval for Pump Relief Request Project stage: Request ML20100L0171985-04-0909 April 1985 Forwards Application Fee,Per NRC ,To Cover 850301 Request for Extension of 10CFR50.49 Equipment Qualification Deadline for Drywell Hydrogen & Oxygen Analyzers Currently Installed at Facility Project stage: Request ML20125E1931985-06-0505 June 1985 Advises of Fees Due for 841111 & 850502 Applications for Amends to Licenses DPR-24 & DPR-27 Re Environ Qualification of Water Regulating Valves & Lift Indicating Assemblies.Fees Due Irrespective of NRC Disposition of Application Project stage: Other ML20126J2931985-06-11011 June 1985 Authorizes Implementation of Proposed ASME Code Pump & Valve Inservice Testing Programs to Be Completed No Later than 850801,per 850328 Request for Relief from Requirements Project stage: Other ML20128A0391985-06-28028 June 1985 Submits Supplemental Info Re Questions Raised During Equipment Qualification (EQ) Insp During Wk of 850520. T-drains on Limitorque Motor Operators Replaced W/Plugs.All EQ Procedures Approved & Ready for Use Project stage: Supplement ML20137E9981985-08-16016 August 1985 Notifies of Problems That May Necessitate Extension of Equipment Qualification Deadline for Primary Containment Hydrogen & Oxygen Gas Analyzers,Per 10CFR50.49(h).Revised Testing Schedule for Analyzers Encl Project stage: Other ML20137T6811985-11-27027 November 1985 Provides Status of Environ Qualification Effort for Drywell Hydrogen & Oxygen analyzers.Architect-engineer Determined Equipment Located in Mild Environ Will Remain Operable During & for at Least 180 Days Following LOCA Project stage: Other ML20141M9031986-02-24024 February 1986 Requests Commitment of Necessary Resources to Address Policy Issues Delaying Resolution of Inservice Testing Program Matters.Interim Relief for Several Inservice Testing Requirements Due to Delay Also Requested Project stage: Other 1982-07-01
[Table View] |
Text
__
UNITED STATES OF AMERICA t
NUCLEAR REGULATORY COMMISSION In the Matter of
)
SACRAMENTO MUNIC' PAL UTILITY
)
DISTRICT
)
(Rancho Seco Nuclear Generating
)
Docket No. 50-312 Station)
)
)
REVISED ORDER FOR MODIFICATION OF LICENSE I.
The Sacramento Municipal Utility District (licensee) is the holder of Facility Operating License No. DPR-54, which authorizes the operation of the Rar ho Seco Nuclear Generating Station, at steady state reactor power i
levels not in excess of 2772 megawatts thermal (rated power).
The facility consists of a pressurized water reactor located at the licensec's site in Sacra:-2nto County, California.
II.
On November 4, 1977, the Union of Concerned Scientists (UCS) filed with the Comission a " Petition for Emergency and Remedial Relief." The petition sought action in two areas:
fire protection for electrical cables, and environment 31 qualification of electrical components.
By Memorandum and Order dated April 13,1978 (7 NRC 400), the Commission denied certain aspects of the petition and, with respect to other aspects, ordered the NRC staff to take several related actions. UCS filed a Petition for Reconsideration on May 2,1978.
By Memorandum and Order, dated May 23, 1980, the Commission reaffirmed its April 13, 1978 decision i
- 801027 N
i i'
I regarding the possible sh' utdown of operating reactors.
However, the
~
1 Commission's May 23, 1980 decision directed licensees and tne NRC staff l
to undertake certain actions.
With respect-to environmental-qualification of safety-related electrical equipment, the Commission determined that the provisions of the two l
staff documents - the Division of Operating Reactors " Guidelines for Evaluat 'ng Envircnmental Qualification of Class lE Electrical Equipment l
in Operating Reactors" (00R Guidelines) and NUREG-0588, " Interim' Staff Position on Environmental Qualification of Safety-Related Electrical Ec'aipant," December 1979 "f orm the rec,viremer.ts which licensees. and a;clicants mus: ceet in order to satis #y :hese aspects cf 10 CP. Part i
50, A;;endix A General Design Criterior (3DC Z), which relate to envi-renmental qualification of safety-relatec electrical equipment." The Com:nissien directed, for replacement parts in cperating plants, "unless
-here are sound reasons to the con:rary, the 19N standard in NUREG-05SE will apply." The Comission also directed the staff to co::plete its 1
(
review of the information sought from licensees by Bulletin 79-01E and to complete its review of environmental qualification of safety-related
- electrical equipment in all operating plants, including the publication
. cf Safety Evaluation Reports, by f ebruary 1,1981.
The Cor: mission
.l
.I Bulletin 79-01B was not sent to licensees for plants under review as part of the staff's Systematic' Evaluatior. Program.
The information sought by Bulletin 79-018 was 'recuested from these licensees by a series of letters and neetings auring the months of, February and 14aren, 1980.
y D**D
.1.D
- _co, o
.m -
1 g.
V r,
x imposed a deadline that, "by no later than June 30, 1982 all safety-related electrical equipment in all operating plants shall be qualified to the D0R Guidelines or NUREG-0588."
The Commission requested the staff to, " keep.the Comr.ission and the public apprised of any further findings of incomplete environmental qualification of safety-related electrical equipment, along with corrective actions taken or planned,"
and requested the staff to provide bi-monthly progress reports to the Commission.
The Commission further directed the staff to add certain documentation requirements to each license after the specific requirements were approved by the Commissicn.
The Comrission alse pointed out that the various deadlines imposed in its Order, "dc no; excuse a licensee from the obligation to modify or replace inadequa e equipment promptly."
III.
The infornation developed during this proceeding emphasizes the ir.portance of adequate documentation, the prompt completion of the review of environ-mental qualification of safety-related electrical equipment, and the prompt completion of any plant modification needed to assure conformance with the 00R Guidelines er NUREG-0558.
A significant aspect of this review is the timely submittal of environmental cualification information by
,3 the er.er.ating plant licensees to enable the staff to complete its reyiew
. in accordance with ~ the Commission's Order.
The staff has a program presently underway Ic reevaluate,. using the_ COR Guidelines and NUREG-055E,.the qualifications of safety-related electrical equipmer.t exposed b
~
q q Q
ys 4
0 1
l i
l e
' I
(
t
?
to environments that may exist.following postulated accidents.
These accidents 'are Lcss of-Coolant Accident and Main Steam Line Break
.inside containment, and High. Energy Line Ersaks 'inside and outside containment.
In this connection the licensee was requested by IEE Bulletin 79-018
- oi January 14, 1980 to provide a detailed review of the environmental qualificaticn of Class ~ 1E electrical equipnent.
This review was to include all equipment required to functior. uncer postulated accident conditiens, both inside and outside the pri..ary containment, and re:cgnize all conditicns s;acified in :.e : '.'.e.in.
Evidence of j
cualificatiorc together with reathcds anc j.sti#ication, was requested.
I Clarification was provided by supplemen a' ;nformation, briefings, and in sorte cases, meetings with the licensee.
Timely ccmpletion of the staff's review of envircnmental qualifica:ica o*f electrical equipment and timely. completion of needed modifications by the -licensee is required to provide continuing reasonable assurance of public health and safety.
Such completion is dependent on the protpt receipt of a complete response by the licensee to the staf#'s requests for information.
However, the licensee's response, to da:.e, is incomplete.
e Thefefore, I -have concluded that the public health, safety, and interest c.
L require that -a: firm schedule for the timely submission of all the informatic(p eviously requested by tne staff should be established c~v xrcer ettectives immeciate '
Mu ugp;
~
O IV.
Accordingly, pursuant to the Atomic Energy Act of 1954, as amended, and the Commission's regulations in 10 CFR Parts 2 and 50, IT IS ORDERED THAT EFFECTIVE IMMEDIATELY Facility Operating License No. DPR-54 is hereby amended to add the following provisions:
"Information which fully and completely responds to the staff's request as specified in I & E Bulletin 79-01B, shall be submitted to the Director, Region V, Office of Inspection and Enforcement, by the licensee not later than November 1,1980."
An earlier response is encouraged to facilitate staff review and issuance of the safety evaluation report.
The licensee or any person whose interest may be affected by this Order may request a hearing within 20 days of the date of publication of this Revised Order in the Federal Register.
Any request for a hearing will not stay the effective date of this Order.
Aqy request for a hearing shall be addressed to the Director, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Hashington, D. C.
20555.
A copy of the request should also be sent to the Executive Legal Director, U. S. Nuclear Regulatory Commission, Washington, D. C.
20555, and to David S. Kaplan, Secretary and General Counsel, 6201 S Street, P. O. Box 15830, Sacramento, California 95814, attorney for the licensee.
a t -
.If a hearin9'is held concerning this Order, the issue to be considered at the hearing shall be whether the license should be modified to require submission of information as set forth in Section IV. of the Order.
Operating of the facility on terms consistent with this Order is. not -
stayed by the pendency of any proceedings on the Order.
This Order revises, in its entirety, the Order issued August 29, 1980, and published in the Federal Register September.12,1980, (45 FR 60518).
FOR THE NUCLEAR REGULATORY COMMISSION
[
DarrellG.E(sennut, Director Division of Licensing Effective Date: September 19, 1980=
Bethesda,.Ma ryland'