public senice company :e c acb P O. BOX 840 DENVER, COLORADO 80201 l August 11, 1980 Mr. Jerome Saltzman, Chief Antitrust & Indemity Group Nuclear Reactor Regulation U. S. N clear Regulatory Commission Washington, D. C. 20555 Re : Docket No. 50-267, 70, 1278

Dear Mr. Saltzman:

This is to report an incident which occurred at our Ft. St.

Vrain Station on August 4,1980.

Due to a malfunction in the helium circulator system, there was a minute release of radioactivity in the reactor building.

The safety of the employees was not jeopardized and there was no measurable release of radioactivity into the atmosphere.

At no time was there any hazard to the public.

Very truly yours, U .s t o A L s J. A. Gaschler Risk Managerrent Director JAG:ss Db s