Ro:On 800501 & 0617,minute Releases of Radioactivity Occurred in Reactor Bldg.Caused by Malfunction in Helium Circulator Sys.No Radiation Was Released Into Atmosphere. Public & Personnel Health & Safety Were Not Jeopardized
ML19318A899
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 06/18/1980
From: Gaschler J
PUBLIC SERVICE CO. OF COLORADO
To:
References
NUDOCS 8006240335
Download: ML19318A899 (1)


Text

. . . .

-.. a i w

U\ -

Pubue service company oe conomeo P.O.80X 840 OENVER. COLORADO 80201 l

l 4j d

._ Aw_) June 18, 1980 .

l 2

Mr. Jerome Saltzman, Chief Antitrust & Indemnity Group Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Re Docket No. 50-267, 70, 1278

Dear Mr. Saltzman:

This is to report two similar incidents which occurred at our Ft. St. Vrain Station on May 1 and June 17, 1980.

  • Due to a malfunction in the helium circulator system, there was a minute release of radioactivty in the reactor building. The safety of the employees was not jeopard:.ted and there was no radiation released into tne atmosphere. At no time was there any hazard to the public.

Very truly yours, c MY'u J. A. Gaschler Risk Management Director JAG:ss l

l Dool 5