DRAFT SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION 1

TECHNICAL SPECIFICATIONS TASK FORCE TRAVELER 2

TSTF-582, REVISION 0, RPV WIC ENHANCEMENTS 3

USING THE CONSOLIDATED LINE ITEM IMPROVEMENT PROCESS 4

(EPID L-2019-PMP-0199) 5 6

1.0 INTRODUCTION

7 8

By letter dated August 28, 2019 (Agencywide Documents Access and Management System 9

(ADAMS) Accession No. ML19240A260), the Technical Specifications Task Force (TSTF) 10 submitted Traveler TSTF-582, Revision 0, RPV [Reactor Pressure Vessel] WIC [Water 11 Inventory Control] Enhancements, to the U.S. Nuclear Regulatory Commission (NRC);

12 hereafter referred to as TSTF-582. TSTF-582 proposed changes to the Standard Technical 13 Specifications (STSs) for boiling-water reactor (BWR) General Electric (GE) plant designs.

14 Upon approval, these changes will be incorporated into future revisions of NUREG-1433 and 15 NUREG-14341 and this traveler will be made available to licensees for adoption through the 16 consolidated line item improvement process.

17 18 The proposed changes would revise technical specifications (TSs) related to RPV WIC to 19 incorporate operating experience and to correct editorial errors in TSTF-542, Revision 2, 20 Reactor Pressure Vessel Water Inventory Control (ADAMS Accession No. ML16074A448).

21 TSTF-542, Revision 2, was approved by the NRC on December 20, 2016 (ADAMS Package 22 Accession No. ML16343B066). Upon approval, TSTF-582 will be available to licensees that 23 have already adopted TSTF-542, Revision 2.

24 25 2.0 REGULTORY EVALUATION 26 27 2.1

System Description

28 29 2.1.1 Reactor Pressure Vessel 30 31 The BWR RPVs have penetrations located below the top of active fuel (TAF). These 32 penetrations provide entry for control rods, recirculation flow, reactor water cleanup (RWCU),

33 and shutdown cooling. Since these penetrations are below the TAF, this creates a potential to 34 drain the reactor vessel water inventory and lose effective core cooling. The loss of water 35 inventory and effective core cooling can potentially lead to fuel cladding failure and radioactive 36 release.

37 38 1 U.S. Nuclear Regulatory Commission, Standard Technical Specifications, General Electric, BWR/4 Plants, NUREG-1433, Volume 1, Specifications, and Volume 2, Bases, Revision 4.0, April 2012 (ADAMS Accession Nos. ML12104A192 and ML12104A193, respectively).

U.S. Nuclear Regulatory Commission, Standard Technical Specifications, General Electric BWR/6 Plants, NUREG-1434, Volume 1, Specifications, and Volume 2, Bases, Revision 4.0, April 2012 (ADAMS Accession Nos. ML12104A195 and ML12104A196, respectively).

During operation in Mode 1 (Power Operation - Reactor Mode Switch in Run), Mode 2 (Startup 1

- Reactor Mode Switch in Refuel1 or Startup/Hot Standby), and Mode 3 (Hot Shutdown1 -

2 Reactor Mode Switch in Shutdown and average reactor coolant temperature greater 3

than (>) [200] degrees Fahrenheit (°F)), the STS for instrumentation and emergency core 4

cooling systems (ECCS) require operability of sufficient equipment to ensure large quantities of 5

water will be injected into the vessel should the level decrease below the preselected value.

6 These requirements are designed to mitigate the effects of a loss-of-coolant accident (LOCA),

7 but also provide protection for other accidents and transients that involve a water inventory loss.

8 9

During BWR operation in Mode 4 (Cold Shutdown1 - Reactor Mode Switch in Shutdown and 10 average reactor coolant temperature less than or equal to () [200] °F), and Mode 5 (Refueling2 -

11 Reactor Mode Switch in Shutdown or Refuel), the pressures and temperatures that could cause 12 a significant mass and energy release due to a LOCA that would require an evaluation with 13 respect to Title 10 of the Code of Federal Regulations (10 CFR) Section 50.46, Acceptance 14 criteria for emergency core cooling systems for light-water nuclear power reactors, are not 15 present. During certain phases of refueling (Mode 5), a large volume of water is available above 16 the RPV (i.e., the RPV head is removed), the water level is greater than or equal to () [23] feet 17 over the top of the RPV flange, and the spent fuel storage pool gates are removed, or the upper 18 containment pool is connected to the RPV. This large volume of water provides time for 19 detection and manual operator action to mitigate an RPV draining event. However, at other 20 times during a refueling outage, during Cold Shutdown (Mode 4) or Refueling (Mode 5), there 21 may be a potential for significant drainage paths from certain outage activities, human error, and 22 other events when it is more likely to have some normally available equipment, instrumentation, 23 and systems inoperable due to maintenance and outage activities. This would result in less time 24 for operator action relative to when there are large volumes of water above the RPV.

25 26 In comparison to Modes 1, 2, and 3, Modes 4 and 5 generally do not have the high pressure 27 and temperature necessary for a LOCA from a high energy pipe failure. Thus, in Mode 4 and 5, 28 while the potential sudden loss of large volumes of water from a LOCA are not expected, 29 operators monitor for a BWR RPV water level decrease from potentially significant or 30 unexpected drainage paths. In Modes 4 and 5 these would require less water replacement 31 capability to maintain water above the TAF.

32 33 2.1.2 Emergency Core Cooling System 34 35 In NUREG-1433, the ECCS consists of the following:

36 37 High pressure coolant injection (HPCI) system, 38 Automatic depressurization system, 39 Core spray (CS) system, and 40 Low pressure coolant injection (LPCI) system, an operating mode of the residual 41 heat removal (RHR) system.

42 43 1 All reactor vessel head closure bolts fully tensioned.

2 One or more reactor vessel head closure bolts less than fully tensioned.

In NUREG-1434, the ECCS consists of the following:

1 2

High pressure core spray (HPCS) system, 3

Automatic depressurization system, 4

Low pressure core spray (LPCS) system, and 5

LPCI system, an operating mode of the RHR system.

6 7

The ECCS is designed to limit clad temperature over the complete spectrum of possible break 8

sizes in the nuclear system process barrier, including the design-basis break. The design-basis 9

break is defined as the complete and sudden circumferential rupture of the largest pipe 10 connected to the reactor vessel (i.e., one of the recirculation loop pipelines) with displacement 11 of the ends so that blowdown occurs from both ends.

12 13 During Modes 4 and 5, two ECCS injection/spray subsystems are required to be OPERABLE in 14 accordance with existing STS 3.5.2 limiting condition for operation (LCO).

15 16 2.1.3 Alternating Current Sources 17 18 The design of the Class 1E alternating current (AC) electrical power system provides 19 independence and redundancy to ensure an available source of power to the engineered safety 20 feature (ESF) systems. The Class 1E AC electrical power system includes offsite power 21 sources and onsite standby power sources (i.e., diesel generators (DGs)) that supply electrical 22 power to the plant load groups, with each load group powered by an independent Class 1E 23 4.16 kilovolt (kV) ESF bus. Each ESF bus has connections to offsite power sources and a DG.

24 25 A DG starts automatically on an ECCS signal (i.e., low reactor vessel water level signal or high 26 drywell pressure signal) or on an ESF bus degraded voltage or undervoltage signal. After the 27 DG starts, it automatically ties to its respective bus after offsite power is tripped because of ESF 28 bus undervoltage or degraded voltage, independent of or coincident with a LOCA signal. In the 29 event of a loss of offsite power (LOOP), the ESF electrical loads are automatically connected to 30 the DG in time to provide for safe reactor shutdown and to mitigate the consequences of a 31 design-basis accident such as a LOCA.

32 33 During shutdown conditions, the DG automatic start is tested in accordance with existing 34 STS 3.8.2 Surveillance Requirement (SR) 3.8.2.1.

35 36 NUREG-1433 37 38 LCO 3.8.2 requires the operability of one offsite circuit and one DG to support the onsite 39 Class 1E AC electrical power distribution subsystem(s) required by LCO 3.8.10, Distribution 40 Systems - Shutdown. The LCO 3.8.2 is applicable in Modes 4 and 5 and during movement of 41

[recently] irradiated fuel assemblies in the [secondary] containment.

42 43 NUREG-1434 44 45 LCO 3.8.2 requires the operability of one offsite circuit and one DG to support the Division 1 or 2 46 onsite Class 1E AC electrical power distribution subsystem(s) required by LCO 3.8.10, 47 Distribution Systems - Shutdown, and one offsite circuit or one DG to support the Division 3 48 onsite Class 1E AC electrical power distribution subsystem(s) when required by LCO 3.8.10.

49 The LCO 3.8.2 is applicable in Modes 4 and 5 and during movement of [recently] irradiated fuel 1

assemblies in the [primary and secondary containment].

2 3

2.2 Proposed Changes to Standard Technical Specifications 4

5 The proposed changes include several improvements and address editorial errors in the STS 6

changes approved in TSTF-542. These were identified during the development of plant-specific 7

license amendments to adopt TSTF-542, and during subsequent refueling outages. TSTF-582 8

states that the proposed changes improve consistency, revise impractical requirements, and 9

address issues with multiple-unit sites that share a secondary containment. The proposed 10 changes include revisions to the Drain Time definition and allow manual valve alignment and 11 pump start, by eliminating the STS 3.3.5.2 requirement for a manual ECCS initiation signal to 12 start the required ECCS injection/spray subsystem. Additionally, TSTF-582 proposed 13 corresponding changes to the STS Bases.

14 15 Since TSTF-542, Revision 2, has not yet been incorporated into a revision of NUREG-1433 and 16 NUREG-1434, the changes approved in the TSTF-542, Revision 2, were used as the basis for 17 the proposed changes inTSTF-582. The proposed changes discussed in this safety evaluation 18 (SE) are identical and applicable to both NUREG-1433 and NUREG-1434, unless otherwise 19 stated in this SE.

20 21 2.2.1 Drain Time Definition 22 23 The phrase (e.g., seismic event, loss of normal power, single human error) would be deleted 24 from Item b) of STS 1.1 Drain Time definition. The phrase closed and administratively 25 controlled would replace locked, sealed, and otherwise secured in Item b)1. of STS 1.1 Drain 26 Time definition.

27 28 2.2.2 Reactor Pressure Vessel Water Inventory Control Instrumentation, STS 3.3.5.2 29 30 TSTF 582 proposes to revise STS 3.3.5.2, RPV Water Inventory Control Instrumentation, to 31 eliminate the requirement for a manual ECCS initiation signal to start the required ECCS 32 injection/spray subsystem, and to instead rely on manual valve alignment and pump start.

33 STS 3.3.5.2 Functions, SRs, and Actions that only support manual initiation using an ECCS 34 signal (including interlocks and minimum flow instruments) would be eliminated. Changes are 35 proposed for STS 3.3.5.2 Table 3.3.5.2-1, Actions, and SRs.

36 37 2.2.2.1 Reactor Pressure Vessel Water Inventory Control Instrumentation, Table 3.3.5.2-1 38 39 NUREG-1433 (without setpoint control program) 40 41 Table 3.3.5.2-1, RPV Water Inventory Control Instrumentation (STS 3.3.5.2A (without setpoint 42 control program)), would be revised to delete the CS and LPCI system Functions and the 43 associated requirements (Applicable Modes or Other Specified Conditions, Required Channels 44 per Function, and Conditions Referenced from Required Action A.1) and Note (a), and 45 references to SRs 3.3.5.2.1, 3.3.5.2.2, and 3.3.5.2.3.

46 47 NUREG-1433 (with setpoint control program) 48 49 Table 3.3.5.2-1, RPV Water Inventory Control Instrumentation (STS 3.3.5.2B (with setpoint 50 control program)), would be revised to delete the CS and LPCI system Functions and the 51 associated requirements (Applicable Modes or Other Specified Conditions, Required Channels 1

per Function, and Conditions Referenced from Required Action A.1) and Note (a), and 2

references to SRs 3.3.5.2.1, 3.3.5.2.2, and 3.3.5.2.3.

3 4

NUREG-1434 (without setpoint control program) 5 6

Table 3.3.5.2-1, RPV Water Inventory Control Instrumentation (STS 3.3.5.2A (without setpoint 7

control program)), would be revised to delete the LPCI, LPCS, and HPCS system Functions and 8

the associated requirements (Applicable Modes or Other Specified Conditions, Required 9

Channels per Function, and Conditions Referenced from Required Action A.1) and Notes (a) 10 and (b), and references to SRs 3.3.5.2.1, 3.3.5.2.2, and 3.3.5.2.3.

11 12 NUREG-1434 (with setpoint control program) 13 14 Table 3.3.5.2-1, RPV Water Inventory Control Instrumentation (STS 3.3.5.2B (with setpoint 15 control program)), would be revised to delete LPCI, LPCS, and HPCS system Functions and the 16 associated requirements (Applicable Modes or Other Specified Conditions, Required Channels 17 per Function, and Conditions Referenced from Required Action A.1) and Notes (a) and (b), and 18 references to SRs 3.3.5.2.1, 3.3.5.2.2, and 3.3.5.2.3.

19 20 2.2.2.2 Reactor Pressure Vessel Water Inventory Control Instrumentation, 21 STS 3.3.5.2 Actions 22 23 NUREG-1433 24 25 The Actions tables of both STS 3.3.5.2A and STS 3.3.5.2B would be revised to permit placing 26 an inoperable isolation channel in trip with a Completion Time of Immediately (as proposed 27 Action A.1) as an alternative (joined with an OR) to declaring the associated penetration flow 28 path incapable of automatic isolation (existing Action B.1). Existing Action A.2 is proposed to be 29 revised to add Initiate action to to the required action of Calculate DRAIN TIME. In addition, 30 due to the proposed deletion of the CS and LPCI system Functions, Actions B, C, D, E, F, and 31 G would no longer be necessary and would be deleted. Due to the deletions, the existing 32 Action B is renumbered as Action A, existing Action B.1 is renumbered as Action A.2.1, and 33 existing Action A.2 is renumbered as A.2.2.

34 35 NUREG-1434 36 37 The Actions tables of both STS 3.3.5.2A and STS 3.3.5.2B would be revised to permit placing 38 an inoperable isolation channel in trip with a Completion Time of Immediately (as proposed 39 Action A.1) as an alternative (joined with an OR) to declaring the associated penetration flow 40 path incapable of automatic isolation (existing Action B.1). Existing Action A.2 is proposed to be 41 revised to add Initiate action to to the required action of Calculate DRAIN TIME. In addition, 42 due to the proposed deletion of the LPCS, HPCS, and LPCI system Functions, Actions B, C, D, 43 E, F, and G would no longer be necessary and would be deleted. Due to the deletions, the 44 existing Action B is renumbered as Action A, existing Action B.1 is renumbered as Action A.2.1, 45 and existing Action A.2 is renumbered as A.2.2.

46 47 2.2.2.3 Reactor Pressure Vessel Water Inventory Control Instrumentation, 1

STS 3.3.5.2 Surveillance Requirements 2

3 The Note over SR 3.3.5.2 would be modified to delete Refer to and to determine which SRs 4

apply for each ECCS Function and would add These SRs apply to each Function in 5

Additionally, SR 3.3.5.2.3, Perform Logic System Functional Test, and its specified frequency 6

would be deleted.

7 8

2.2.3 Primary Containment Isolation Instrumentation, STS 3.3.6.1 9

10 The requirement to immediately initiation Action J.2 Initiate action to isolate the Residual Heat 11 Removal (RHR) Shutdown Cooling System of STS 3.3.6.1A, Primary Containment Isolation 12 Instrumentation (without setpoint control program), and STS 3.3.6.1B, Primary Containment 13 Isolation Instrumentation (with setpoint control program) would be deleted.

14 15 2.2.4 Reactor Pressure Vessel Water Inventory Control, STS 3.5.2 16 17 STS 3.5.2 would be revised to allow manual valve alignment and pump start, in place of the 18 requirement for a manual ECCS initiation signal to start the required ECCS injection/spray 19 subsystem. STS 3.5.2 SRs related to manual initiation using the ECCS signal (such as verifying 20 automatic alignment of valves on an initiation signal) would be deleted.

21 22 2.2.4.1 Reactor Pressure Vessel Water Inventory Control, STS 3.5.2, Condition D 23 24 STS 3.5.2, Condition D, which applies when Drain Time is < 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, requires immediate action 25 to isolate each [secondary] containment penetration flow path or to verify that it can be manually 26 isolated from the control room. At some BWR sites, the secondary containment is shared 27 between units and the secondary containment and the secondary containment isolation valves 28 (SCIVs) may be required to be operable per STS 3.6.4.1 and STS 3.6.4.2 for the operating unit 29 while STS 3.5.2 is applicable for a shutdown unit in Modes 4 and 5.

30 31 To accommodate this shared design, a bracketed (i.e., optional) proposed change shown in 32 bold would be made to Required Action D.3, which will state, Initiate action to isolate each 33

[secondary] containment penetration flow path or verify it can be [automatically or] manually 34 isolated from the control room. This will allow automatic closure of SCIVs for sites with a 35 shared secondary containment. Automatic closure of the SCIVs provides protection equivalent 36 to manual isolation of the SCIVs from the control room.

37 38 2.2.4.2 Reactor Pressure Vessel Water Inventory Control, STS 3.5.2, Surveillance 39 Requirements 40 41 SR 3.5.2.5, Verify, for the required ECCS injection/spry subsystem, each manual, 42 power-operated, and automatic valve in the flow path, that is not locked, sealed, or otherwise 43 secured in position, is in the correct position. and its specific frequency would be deleted. Two 44 notes would be added to SR 3.5.2.6 which state Operation may be through the test return line.

45 and Credit may be taken for normal system operation to satisfy this SR. SR 3.5.2.7 would be 46 revised to replace actuates on a manual injection signal with can be manually operated.

47 Additionally, SRs 3.5.2.6, 3.5.2.7, and 3.5.2.8 would be renumbered as SRs 3.5.2.5, 3.5.2.6, 48 and 3.5.2.7.

49 50 2.2.5 Primary Containment Isolation Valves, STS 3.6.1.3 1

2 NUREG-1433 3

4 The proposed revision to the Applicability of STS 3.6.1.3, Primary Containment Isolation Valves 5

(PCIVS), would delete the phrase, When associated instrumentation is required to be 6

OPERABLE per LCO 3.3.6.1, Primary Containment Isolation Instrumentation.

7 8

This change would make STS 3.6.1.3 only applicable in Modes 1, 2, and 3. Condition H, which 9

is only applicable in Modes 4 and 5, and Condition G, which is only applicable during movement 10 of irradiated fuel in the secondary containment, would be deleted.

11 12 The proposed change to STS 3.6.1.3, Condition F would delete in MODE 1, 2, or 3.

13 14 Existing Conditions G and H are shown below. These conditions are proposed to be deleted.

15 16 CONDITION REQUIRED ACTION COMPLETION TIME G. [Required Action and associated Completion Time of Condition A, B, C, D, or E not met for PCIV(s) required to be OPERABLE during movement of [recently]

irradiated fuel assemblies in

[secondary] containment.

G.1 -----------NOTE--------------

LCO 3.0.3 is not applicable.

Suspend movement of

[recently] irradiated fuel assemblies in [secondary]

containment.

Immediately]

H. [Required Action and associated Completion Time of Condition A, B, C, D, or E not met for PCIV(s) required to be OPERABLE during MODE 4 or 5.

H.1 Initiate action to restore valve(s) to OPERABLE status.

Immediately]

17 Notes stating that the SR is Only required to be met in MODES 1, 2, and 3 on SR 3.6.1.3.1, 18 SR 3.6.1.3.2, SR 3.6.1.3.7, SR 3.6.1.3.12, SR 3.6.1.3.13, SR 3.6.1.3.14, and SR 3.6.1.3.15 19 would be deleted.

20 21 2.2.6 Alternating Current Sources - Shutdown, STS 3.8.2 22 23 The proposed revision to STS 3.8.2, AC Sources - Shutdown, SR 3.8.2.1, would no longer 24 require SRs that test automatic DG start to be met in Modes 4 and 5. Note 1 of SR 3.8.2.1 25 would be revised to remove SRs 3.8.1.11, 3.8.1.13, and 3.8.1.19 from the list of SRs that are 26 not required to be performed. Note 2 of SR 3.8.2.1, which states SR 3.8.1.12 and SR 3.8.1.19 27 are not required to be met when associated SCS subsystem(s) are not required to be 28 OPERABLE per LCO 3.5.2, ECCS Shutdown. would be deleted. SR 3.8.2.1 would be revised 29 to add SRs 3.8.1.11, 3.8.1.12, 3.8.1.13, and 3.8.1.19 to the list of SRs that are excepted from 30 the applicability. Additionally, NOTES would be changed to NOTE and the numbering 31 removed, since only one Note would remain in the SR.

32 33 2.2.7 Editorial Changes 1

2 Several editorial changes are proposed as described below.

3 4

In STS 3.5.2, Required Action C.3, the insertion of the acronym for standby gas treatment 5

(SGT) between standby gas treatment and subsystem.

6 7

In STS 3.5.2, Required Action D.3, (SGT) would replace standby gas treatment, which would 8

be deleted.

9 10 NUREG-1433 11 12 SR 3.5.2.2 would be revised to delete low pressure coolant injection (LPCI), and replace it with 13 LPCI.

14 15 NUREG-1434 16 17 STS 3.5.1, ECCS-Operating, Actions Note would be revised to define the acronym HPCS at its 18 first use and to remove the definition from Condition B.

19 20 The proposed revised note is, LCO 3.0.4.b is not applicable to High Pressure Core Spray 21 (HPCS).

22 23 The proposed revised Condition B is, HPCS System inoperable.

24 25 2.3 Applicable Regulatory Requirements and Guidance 26 27 As described in the Commissions Final Policy Statement on Technical Specifications 28 Improvements for Nuclear Power Reactors (58 FR 39132, dated July 22, 1993), the NRC and 29 industry task groups for new STSs recommended that improvements include greater emphasis 30 on human factors principles in order to add clarity and understanding to the text of the STSs, 31 and provide improvements to the Bases of the STSs, which provides the purpose for each 32 requirement in the STSs. The improved vendor-specific STSs were developed and issued by 33 the NRC in September 1992.

34 35 Section IV, The Commission Policy, of the Final Policy Statement on TSs states, in part:

36 37 The purpose of Technical Specifications is to impose those 38 conditions or limitations upon reactor operation necessary to 39 obviate the possibility of an abnormal situation or event giving rise 40 to an immediate threat to the public health and safety by 41 identifying those features that are of controlling importance to 42 safety and establishing on them certain conditions of operation 43 which cannot be changed without prior Commission approval.

44 45

[T]he Commission will also entertain requests to adopt portions 46 of the improved STS [(e.g., TSTF-582)], even if the licensee does 47 not adopt all STS improvements. The Commission encourages 48 all licensees who submit Technical Specification related submittals 49 based on this Policy Statement to emphasize human factors 50 principles.

51 In accordance with this Policy Statement, improved STS have 1

been developed and will be maintained for each NSSS [nuclear 2

steam supply system] owners group. The Commission 3

encourages licensees to use the improved STS as the basis for 4

plant-specific Technical Specifications. [I]t is the Commission 5

intent that the wording and Bases of the improved STS be used 6

to the extent practicable.

7 8

The Summary section of the Final Policy Statement on TS states, in part:

9 10 Implementation of the Policy Statement through implementation of 11 the improved STS is expected to produce an improvement in the 12 safety of nuclear power plants through the use of more 13 operator-oriented Technical Specifications, Improved Technical 14 Specification Bases, reduced action statement induced plant 15 transients, and more efficient use of NRC and industry resources.

16 17 The regulation under 10 CFR 50.36(a)(1) requires that:

18 19 Each applicant for a license authorizing operation of a 20 utilization facility shall include in his application proposed technical 21 specifications in accordance with the requirements of this section.

22 A summary statement of the bases or reasons for such 23 specifications, other than those covering administrative controls, 24 shall also be included in the application, but shall not become part 25 of the technical specifications.

26 27 The regulation under 10 CFR 50.36(b) requires that:

28 29 Each license authorizing operation of a utilization facility will 30 include technical specifications. The technical specifications will 31 be derived from the analyses and evaluation included in the safety 32 analysis report, and amendments thereto, submitted pursuant to 33

[10 CFR] 50.34 [Contents of applications; technical information].

34 The Commission may include such additional technical 35 specifications as the Commission finds appropriate.

36 37 The categories of items required to be in the TSs are listed in 10 CFR 50.36(c).

38 39 The regulation at 10 CFR 50.36(c)(2) requires that TSs include LCOs. Per 10 CFR 40 50.36(c)(2)(i), LCOs are the lowest functional capability or performance levels of equipment 41 required for safe operation of the facility. The regulation also requires that when an LCO of a 42 nuclear reactor is not met, the licensee shall shut down the reactor or follow any remedial action 43 permitted by the TS until the condition can be met.

44 45 The regulation at 10 CFR 50.36(c)(3) requires that TSs include items in the category of SRs, 46 which are requirements relating to test, calibration, or inspection to assure that the necessary 47 quality of systems and components is maintained, that facility operation will be within safety 48 limits, and that the LCOs will be met.

49 50 The NRC staffs guidance for the review of TSs is in Chapter 16.0, Technical Specifications, of 1

NUREG-0800, Revision 3, Standard Review Plan for the Review of Safety Analysis Reports for 2

Nuclear Power Plants: LWR [Light-Water Reactor] Edition (SRP), March 2010 (ADAMS 3

Accession No. ML100351425). As described therein, as part of the regulatory standardization 4

effort, the NRC staff has prepared STSs for each of the LWR nuclear designs. Accordingly, the 5

NRC staffs review includes consideration of whether the proposed changes are consistent with 6

the applicable referenced STSs (i.e., the current STSs), as modified by NRC-approved 7

travelers. In addition, the guidance states that comparing the change to previous STSs can 8

help clarify the STSs intent.

9 10

3.0 TECHNICAL EVALUATION

11 12 3.1 Drain Time Definition, STS 1.1 13 14 TSTF-582 proposed to delete (e.g., seismic event, loss of normal power, single human error) 15 from STS 1.1 Drain Time definition, Item b. The NRC finds the deletion of these examples of 16 common failures acceptable because this level of detail is not required by 10 CFR 50.36(a)(1).

17 A conforming change is proposed to the bases to eliminate discussion of seismic events and 18 snubbers, and to state that the maintenance controls described in NUMARC 93-01 to prevent a 19 loss of inventory, and the licensee commitments to NUREG-0612, Control of Heavy Loads at 20 Nuclear Power Plants, are sufficient to prevent a failure related to maintenance and testing that 21 could result in a draining event.

22 23 TSTF-582 proposed to replace locked, sealed, or otherwise secured with closed and 24 administratively controlled in Item b)1 of the Drain Time definition.

25 26 The current STS definition requirement that closed manual or automatic valves must be locked, 27 sealed, or otherwise secured cannot be practically implemented in a large population of valves, 28 because the penetration flow paths are connected to systems, such as RHR and RWCU, that 29 have tens or hundreds of manual valves, such as vents, drains, and sample connections.

30 These manual valves are normally closed and are controlled under the licensee's administrative 31 processes, such as system operating procedures. Additionally, accessing these valves to meet 32 the current definition would lead to unnecessary radiation dose and foreign material control 33 concerns in the drywell.

34 35 The NRC staff finds that revision of the Drain Time definition, Item b)1 to require that excluded 36 penetration flow paths be isolated by manual or automatic valves that are closed and 37 administratively controlled is acceptable, because accessing these valves to meet the current 38 definition would lead to unnecessary radiation dose and foreign material control concerns in the 39 drywell. The current definition requirement that closed manual or automatic valves must be 40 locked, sealed, or otherwise secured cannot be practically implemented in a large population of 41 valves, because the penetration flow paths are connected to systems, such as RHR and 42 RWCU, that have tens or hundreds of manual valves, such as vents, drains, and sample 43 connections. These manual valves are normally closed and are controlled under the licensee's 44 administrative processes, such as system operating procedures. Administrative controls are 45 acceptable because they are inspectable, are accepted methods to control system configuration 46 during the dynamic conditions of a refueling outage, and provide assurance that the valves 47 would be closed and controlled as needed to prevent flow of reactor coolant through the 48 penetration flow paths in time such that the water inventory in the RPV to would not drain down 49 to below TAF.

50 51 3.2 Reactor Pressure Vessel Water Inventory Control Instrumentation, STS 3.3.5.2 1

2 3.2.1 STS Table 3.3.5.2-1 3

4 The STS 3.3.5.2 functions that only support ECCS manual initiation via the ECCS 5

instrumentation would be removed from Table 3.3.5.2-1 in LCO 3.3.5.2A and LCO 3.3.5.2B.

6 7

NUREG-1433 (with and without setpoint control program) 8 9

Functions 1.a and 2.a, CS System and LPCI System Reactor Steam Dome Pressure - Low 10 (Injection Permissive) 11 12 The low reactor steam dome pressure signals are used as permissives for the low pressure 13 ECCS injection/spray subsystem manual initiation Functions. This function ensures that, prior 14 to opening the injection valves of the low pressure ECCS subsystems, the reactor pressure has 15 fallen to a value below these subsystems maximum design pressure. In Modes 4 and 5, the 16 reactor steam dome pressure is lower than the ECCS maximum design pressure. Therefore, 17 the NRC staff finds that the functions are not necessary to ensure that the required ECCS 18 subsystem can inject into the RPV.

19 20 Functions 1.b and 2.b, CS System and LPCI System Pump Discharge Flow - Low (Bypass) 21 22 The minimum flow instruments protect the associated low pressure ECCS pump from 23 overheating when the pump is operating, and the associated injection valve is not fully open.

24 The minimum flow line valve is opened when low flow is sensed, and the valve is automatically 25 closed when the flow rate is adequate to protect the pump. Under the proposed change, the 26 ECCS pump is started manually by the operator after aligning the valves needed to inject into 27 the RPV. Therefore, the NRC staff finds that the automatic minimum flow protection is not 28 needed.

29 30 Functions 1.c and 2.c, CS System and LPCI System Manual Initiation 31 32 The Manual Initiation push button channels introduce signals into the appropriate ECCS logic to 33 provide manual initiation capability. Under the proposed change, the ECCS is aligned and 34 started by the operators from the control room. Therefore, the NRC staff finds that the manual 35 initiation function is not needed.

36 37 NUREG-1434 (with and without setpoint control program) 38 39 Functions 1.a and 2.a, LPCS System and LPCI System Reactor Steam Dome Pressure - Low 40 (Injection Permissive) 41 42 The low reactor steam dome pressure signals are used as permissives for the low pressure 43 ECCS injection/spray subsystem manual initiation Functions. This function ensures that, prior 44 to opening the injection valves of the low pressure ECCS subsystems, the reactor pressure has 45 fallen to a value below these subsystems maximum design pressure. In Modes 4 and 5, the 46 reactor steam dome pressure is lower than the ECCS maximum design pressure. Therefore, 47 the NRC staff finds that the functions are not necessary to ensure the required ECCS 48 subsystem can inject into the RPV.

49 50 Functions 1.b, 1.c, and 2.b, LPCS and LPCI Systems Pump Discharge Flow - Low (Bypass) 1 2

The minimum flow instruments protect the associated low pressure ECCS pump from 3

overheating when the pump is operating, and the associated injection valve is not fully open.

4 The minimum flow line valve is opened when low flow is sensed, and the valve is automatically 5

closed when the flow rate is adequate to protect the pump. Under the proposed change, the 6

ECCS pump is started manually by the operator after aligning the valves needed to inject into 7

the RPV. Therefore, the NRC staff finds that the automatic minimum flow protection is not 8

needed.

9 10 Functions 1.d and 2.c, LPCS System and LPCI System Manual Initiation 11 12 The Manual Initiation push button channels introduce signals into the appropriate ECCS logic to 13 provide manual initiation capability. Under the proposed change, the ECCS is aligned and 14 started by the operators from the control room. Therefore, the NRC staff finds that the manual 15 initiation function is not needed.

16 17 Function 3.a, HPCS System Reactor Vessel Water Level - High, Level 8 18 19 The high RPV water level 8 signal is used to close the HPCS injection valve to prevent overflow 20 into the main steam lines (MSLs). Under the proposed change, the ECCS pump is started and 21 controlled manually by the operator. Therefore, the NRC staff finds that automatic protection to 22 prevent overflow into the MSLs is not needed.

23 24 Function 3.b, HPCS System Condensate Storage Tank (CST) Level - Low 25 26 Low level in the CST indicates the unavailability of an adequate supply of makeup water from 27 this normal source. Normally, the suction valves between HPCS and the CST are open and 28 water for HPCS injection would be taken from the CST. However, if the water level in the CST 29 falls below a preselected level, first the suppression pool suction valve automatically opens and 30 then the CST suction valve automatically closes. This ensures that an adequate supply of 31 makeup water is available to the HPCS pump. Under the proposed change, the ECCS 32 subsystem is aligned and started manually by the operator in the control room, including 33 selecting the water source for HPCS. Therefore, the NRC staff finds that this automatic swap-34 over to the suppression pool is not needed.

35 36 Function 3.c and 3.d, HPCS Pump Discharge Pressure - High (Bypass) and HPCS System 37 Flow Rate - Low (Bypass) 38 39 The minimum flow instruments are provided to protect the HPCS pump from overheating when 40 the pump is operating, and the associated injection valve is not fully open. The minimum flow 41 line valve is opened when low flow and high pump discharge pressure are sensed, and the 42 valve is automatically closed when the flow rate is adequate to protect the pump, or the 43 discharge pressure is low (indicating that the HPCS pump is not operating). Under the 44 proposed change, the ECCS pump is started manually by the operator after aligning the valves 45 needed to inject into the RPV. Therefore, the NRC staff finds that the automatic minimum flow 46 protection is not needed.

47 48 Function 3.e, HPCS System Manual Initiation 1

2 The Manual Initiation push button channel introduces a signal into the HPCS logic to provide 3

manual initiation capability. Under the proposed change, the ECCS is aligned and started by 4

the operators from the control room. Therefore, the NRC staff finds that the manual initiation 5

function is not needed.

6 7

3.2.1.1 Summary of NRC Staff Evaluation of Proposed Changes to Table 3.3.5.2-1 8

9 The NRC staff finds that the safety features provided by the instrumentation functions for CS 10 and LPCI systems (NUREG-1433) and LPCS, LPCI, and HPCS systems (for NUREG-1434) 11 discussed above are not needed in Modes 4 and 5 when crediting manual alignment and pump 12 start of the required ECCS injection/spray subsystem, because there is no specified safety 13 function being performed that would require the functions to be operable. Therefore, the 14 functions can be deleted from Table 3.3.5.2-1. If any of these functions are needed to satisfy 15 manual alignment and pump start from the control room, the function will remain available 16 although it is not required. The automatic function can be bypassed to allow manual operation.

17 Plant-specific procedures which are inspected in accordance with Inspection Procedure 42700, 18 from IMC 2515, Light-Water Reactor Inspection Program, will ensure that no failed or 19 inoperable instrumentation will prevent ECCS injection/spray subsystem injection when needed 20 in the event of an unplanned drain down event. Proposed SR 3.5.2.7 provides assurance that 21 the required ECCS injection/spray subsystem can be manually operated.

22 23 Manually aligning an ECCS injection/spray subsystem to a water source (CST or suppression 24 pool) and injecting water into the RPV is an uncomplicated action and is similar to other actions 25 performed during refueling outages in that they use procedures to perform these actions.

26 Additionally, a draining event is a slow evolution and there is adequate time to take the 27 necessary actions to manually align and start an ECCS injection/spray subsystem. The ECCS 28 subsystems are routinely used to raise the RPV and refueling pool water level during refueling 29 outages without the use of the ECCS manual initiation function.

30 31 The proposed change makes the treatment of instrumentation for the required ECCS 32 injection/spray subsystem consistent with the treatment of RHR in Modes 4 and 5. Similar to 33 the proposed treatment of the defense-in-depth ECCS subsystem, RHR is manually aligned and 34 controlled by the operator in the control room. The RHR STSs describe the required functional 35 capability of the system, but not the specific instruments and controls needed by the operator to 36 accomplish the function.

37 38 The NRC staff finds it acceptable to remove the SRs and footnotes related to the above noted 39 instrumentation from Table 3.3.5.2-1 because the functions they are surveilling are not 40 necessary to ensure the required ECCS subsystem can inject into the RPV, automatic minimum 41 flow protection, provide automatic protection to prevent overflow into the MSLs, automatic swap-42 over to the suppression pool, automatic minimum flow protection, and the manual initiation 43 function. Instrumentation and controls required to support the needed functions will be available 44 per the operability requirements in the plant-specific TSs in Section 1, Definitions. The NRC 45 staff also finds that proposed changes to Table 3.3.5.2-1 correctly specify the lowest functional 46 capability or performance levels of equipment required for safe operation of the facility in 47 accordance with 10 CFR 50.36(c)(2)(i).

48 49 3.2.2 Reactor Pressure Vessel Water Inventory Control Instrumentation, 1

STS 3.3.5.2 Actions 2

3 STS 3.3.5.2 specifies the instrumentation requirements needed to satisfy the operability 4

requirements of STS 3.5.2. There are two types of required instruments: those related to 5

isolation of a penetration flow path on low water level in the RPV, and those functions that are 6

needed to permit manual initiation of the required ECCS subsystem using the ECCS 7

instrumentation.

8 9

As a result of the proposed deletion of instrumentation in Table 3.3.5.2-1, TSTF-582 proposes 10 to delete from STS 3.3.5.2 Actions B, C, D, and E (NUREG-1433) and Actions B, C, D, E, F, 11 and G (NUREG-1434), which are only applicable when these instrumentation functions are 12 inoperable.

13 14 The NRC staff finds that the proposed revisions to STS 3.3.5.2 to remove Conditions related to 15 instrumentation functions that are deleted from Table 3.3.5.2-1 are acceptable. STS 3.3.5.2 is 16 revised to delete Actions B, C, D, and E (NUREG-1433) and Actions B, C, D, E, F, and G 17 (NUREG-1434), which are only applicable when these instrumentation functions are inoperable.

18 These instrumentation functions are not needed in Modes 4 and 5 when crediting manual 19 alignment and pump start of the required ECCS injection/spray subsystem and therefore can be 20 deleted.

21 22 Both RHR and RWCU serve to isolate the subject systems from the RPV on low water level to 23 terminate a draining event before the water level reaches the TAF. Both functions require two 24 channels in one trip system to be operable and are required to be operable when automatic 25 isolation of the associated penetration flow path(s) is credited as an exclusion when calculating 26 Drain Time. If a channel is inoperable, Action A requires immediately declaring the associated 27 penetration flow path(s) incapable of automatic isolation and initiation of action to recalculate 28 Drain Time. Both functions actuate on a two-out-of-two logic. If a channel is placed in the 29 tripped condition, the remaining operable channel will isolate the associated penetration flow 30 path if needed. If both channels are in trip, the penetration flow path will be automatically 31 isolated, fulfilling the safety function. Therefore, the proposed new Required Action A.1 added 32 to STS 3.3.5.2 would require initiating action immediately to place the channel in trip. This 33 Required Action is joined by a logical OR as an alternative to the existing Required Actions.

34 The NRC staff finds the proposed changes to STS 3.3.5.2 acceptable because instrumentation 35 and controls required to support the needed functions will be available per the operability 36 requirements in Section 1, Definitions, of the individual plant TSs.

37 38 3.2.3 Reactor Pressure Vessel Water Inventory Control Instrumentation, STS 3.3.5.2 39 Surveillance Requirements 40 41 STS 3.3.5.2 would be revised to delete SR 3.3.5.2.3, Logic System Functional Test, and to 42 modify the SR NOTE. SR 3.3.5.2.3, which requires a Logic System Functional Test of the 43 ECCS manual initiation function, is no longer necessary because these instrumentation 44 functions are deleted. The Logic System Functional Test was applicable to Table 3.3.5.2 for 45 CS and LPCI (NUREG-1433) and LPCS, LPCI, and HPCS (NUREG-1434) manual initiation 46 instrumentation. The Note for STS 3.3.5.2 SRs would be revised to state, These SRs apply to 47 each Function in Table 3.3.5.2-1.

48 49 The NRC staff finds the deletion of the logic system functional testing (SR 3.3.5.2.3) associated 50 with manual initiation instrumentation for CS and LPCI (NUREG-1433) and LPCS, LPCI, and 51 HPCS (NUREG-1434) acceptable. If manual operation of the required ECCS injection/spray 1

subsystem is needed to add water to the RPV, it is a simple evolution that involves the 2

manipulation of a small number of components by licensed operators in the control room and is 3

described in plant procedures. Manual operation is acceptable because a draining event is a 4

slow evolution and there is adequate time to take the necessary actions to manually align and 5

start an ECCS injection/spray subsystem.

6 7

The NRC staff determined that the modified NOTEs to SRs 3.3.5.2.1 and 3.3.5.2.2 clarify the 8

applicability of the SRs. Therefore, the NRC staff finds the proposed changes are acceptable 9

because the changes continue to assure that the necessary quality of systems and components 10 is maintained, that facility operation will be within safety limits, and that the associated LCO will 11 continue to be met in accordance with 10 CFR 50.36(c)(3).

12 13 3.3 Primary Containment Isolation Instrumentation, STS 3.3.6.1 14 15 NUREG-1433 (without and with setpoint control program) 16 17 STS 3.3.6.1A and STS 3.3.6.1B, Primary Containment Isolation Instrumentation Action J.2 is 18 proposed for deletion.

19 20 TSTF-542 revised NUREG-1433 and NUREG-1434 STS 3.3.6.1, Primary Containment 21 Isolation Instrumentation, to relocate all functions applicable in Modes 4 and 5 to TS 3.3.5.2, 22 Reactor Pressure Vessel Water Inventory Control Instrumentation. TSTF-542 deleted 23 STS 3.3.6.1, Required Action J.2, Initiate action to isolate the Residual Heat Removal (RHR) 24 Shutdown Cooling System, from NUREG-1434, but did not delete the same action from 25 NUREG-1433.

26 27 The deletion of STS 3.3.6.1, Required Action J.2 was an inadvertent omission from the 28 TSTF-542, NUREG-1433 changes. Because this action is no longer applicable after adoption of 29 TSTF-542, since instrumentation actions for Modes 4 and 5 have been moved to STS 3.3.5.2, 30 the NRC staff finds the deletion of the action from NUREG-1433 acceptable.

31 32 3.4 Reactor Pressure Vessel Water Inventory Control, STS 3.5.2 33 34 STS 3.5.2 would be revised to eliminate the requirement for a manual ECCS initiation signal to 35 start the required ECCS injection/spray subsystem, and to instead rely on manual valve 36 alignment and pump start.

37 38 3.4.1 STS 3.5.2, Condition D 39 40 At some BWR sites1, the secondary containment is shared between units and the secondary 41 containment and the SCIVs may be required to be operable per STS 3.6.4.1 and STS 3.6.4.2 42 for the operating unit while STS 3.5.2 is applicable for a shutdown unit in Modes 4 and 5).

43 STS 3.5.2, Condition D, which applies when Drain Time is < 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, requires immediate action 44 to isolate each [secondary] containment penetration flow path or verify that it can be manually 45 isolated from the control room.

46 47 1 The following sites have a shared secondary containment: Browns Ferry, Brunswick, Dresden, Hatch, LaSalle, Limerick, Peach Bottom, Quad Cities, and Susquehanna.

To accommodate this shared design, a bracketed (i.e., optional) proposed change shown in 1

bold would be made to Required Action D.3 which states, Initiate action to isolate each 2

[secondary] containment penetration flow path or verify it can be [automatically or] manually 3

isolated from the control room.

4 5

At sites with a shared secondary containment, the SCIVs may close automatically. A 6

requirement to verify that the SCIVs can only be manually isolated from the control room is not 7

needed, since automatic closure of the SCIVs provides protection equivalent to manual isolation 8

of the SCIVs from the control room. Therefore, the NRC finds that it is acceptable to include in 9

brackets the option of automatic isolation to address shared secondary containments. The 10 action to be taken when the LCO is not met continues specify the lowest functional capability or 11 performance levels of equipment required for safe operation of the facility in accordance with 12 10 CFR 50.36(c)(2)(i).

13 14 3.4.2 STS 3.5.2, Surveillance Requirements 15 16 STS 3.5.2 is revised to delete SRs related to manual initiation using the ECCS signal (such as 17 verifying automatic alignment of valves on an initiation signal). There are no proposed changes 18 to the SR 3.5.2 Frequency.

19 20 3.4.2.1 SR 3.5.2.5 21 22 SR 3.5.2.5 would be replaced with a new SR 3.5.2.7. SR 3.5.2.5 requires verification that each 23 manual, power operated, and automatic valve in the required ECCS injection/spray subsystem 24 flow path that is not locked, sealed, or otherwise secured in position is in the correct position.

25 The requirement that the ECCS injection/spray subsystem valves continuously be in the correct 26 position is replaced with the requirement that the required ECCS subsystem be capable of 27 manual alignment and initiation from the control room. A manually operated ECCS 28 injection/spray subsystem is proposed as new SR 3.5.2.7.

29 30 As a result of the deletion of SR 3.5.2.5, SR 3.5.2.6, SR 3.5.2.7, and SR 3.5.2.8 would be 31 renumbered as SR 3.5.2.5, SR 3.5.2.6, and SR 3.5.2.7, respectively. The renumbering is 32 acceptable because it appropriately reflects the deletion of SR 3.5.2.5.

33 34 There is no longer a specified correct position for the subsystem valves to support initiation 35 from the ECCS instrumentation. The changes to STS 3.5.2 no longer credit the use of 36 automatic valves that respond to an ECCS signal. The STS 3.5.2 permits the use of operator 37 action to align power operated valves. Licensee control of manual valves will be as needed to 38 support manual alignment and initiation of the ECCS subsystem from the control room.

39 Therefore, the NRC staff finds that replacing SR 3.5.2.5 with SR 3.5.2.7, is acceptable because 40 the changes continue to assure that the necessary quality of systems and components is 41 maintained, that facility operation will be within safety limits, and that the associated LCO will 42 continue to be met in accordance with 10 CFR 50.36(c)(3).

43 44 3.4.2.2 SR 3.5.2.6 (renumbered as SR 3.5.2.5) 1 2

SR 3.5.2.6 requires operating the required ECCS subsystem for at least 10 minutes through the 3

recirculation line. The purpose of the SR is to demonstrate that the subsystem is available to 4

mitigate an event. One of the low pressure ECCS subsystems that can satisfy the LCO 5

requirement is RHR Shutdown Cooling. One RHR Shutdown Cooling subsystem is typically in 6

operation when in Mode 4 or Mode 5, which demonstrates that it is capable of injecting water 7

into the RPV to mitigate an event.

8 9

The change would remove the phrase through the recirculation line from the SR and add two 10 notes. The first proposed Note states that operation may be through the test return line. The 11 second proposed Note states that credit may be taken for normal system operation to satisfy the 12 SR. This Note permits crediting the normal operation of an RHR Shutdown Cooling subsystem 13 to satisfy the SR.

14 15 The NRC staff finds that the revised SR continues to ensure that the ECCS injection/spray 16 subsystem can inject water into the RPV if needed for defense-in-depth, while eliminating 17 unnecessary testing. ECCS injection spray subsystem testing remains 10 minutes; however, 18 the use of test return line terminology versus recirculation line, can prevent operator 19 confusion. The two Notes clarify that operations may be through the return line and that credit 20 is taken for normal operations of RHR System in shutdown cooling mode. Therefore, the NRC 21 staff finds changes to SR 3.5.2.6 (renumbered as SR 3.5.2.5) are acceptable because they are 22 appropriate for ensuring the operability of the equipment and instrumentation specified in 23 LCO 3.5.2. Furthermore, the NRC staff concludes that each of the proposed SRs are 24 acceptable, because the SRs continue to assure that the necessary quality of systems and 25 components is maintained, that facility operation will be within safety limits, and that the 26 associated LCO will continue to be met in accordance with 10 CFR 50.36(c)(3).

27 28 3.4.2.3 SR 3.5.2.8 (renumbered as SR 3.5.2.7) 29 30 SR 3.5.2.8 requires verification that the ECCS injection/spray subsystem actuates on a manual 31 initiation signal. SR 3.5.2.8 would be revised to state, Verify the required ECCS injection/spray 32 subsystem can be manually operated. This proposed change reflects the proposed change to 33 the LCO and is consistent with the approved TSs of plants that requested a variation from 34 TSTF-542 for manual ECCS initiation (e.g., Hatch 1 and 2 approval, ADAMS Accession 35 No. ML18123A368).

36 37 Some plants have in their design the capability to manually initiate with a push button. For 38 plants that do not have a push button manual initiation, the RPV injection function (including 39 pumps and valves) would be tested within this SR. This SR verifies that the required ECCS 40 injection/spray subsystem (including the associated pump switches and valve(s)) can be 41 manually operated to provide additional RPV water inventory, if needed. The NRC staff finds 42 the change to SR 3.5.2.8 (renumbered as SR 3.5.2.7) acceptable because it is appropriate for 43 ensuring the operability of the equipment and instrumentation specified in LCO 3.5.2.

44 Furthermore, the NRC staff concluded that change continues to assure that the necessary 45 quality of systems and components is maintained, that facility operation will be within safety 46 limits, and that the associated LCO will continue to be met in accordance with 10 CFR 47 50.36(c)(3).

48 49 3.5 Primary Containment Isolation Valves, STS 3.6.1.3 1

2 NUREG-1433 3

4 Applicability of STS 3.6.1.3, Primary Containment Isolation Valves (PCIVs), would be revised 5

to delete the phrase, When associated instrumentation is required to be OPERABLE per 6

LCO 3.3.6.1, Primary Containment Isolation Instrumentation. TSTF-542 revised the 7

NUREG-1433 Table 3.3.6.1-1, Function 6.b, "Shutdown Cooling Isolation, Reactor Vessel Water 8

Level - Low, Level 3," to relocate the Modes 4 and 5 applicability to STS 3.3.5.2. As a result, all 9

instruments required by LCO 3.3.6.1 are only applicable in Modes 1, 2, or 3. With this change, 10 STS 3.6.1.3 would only be applicable in Modes 1, 2, and 3.

11 12 Condition H, which is only applicable in Modes 4 and 5, and Condition G, which is only 13 applicable during movement of irradiated fuel in the secondary containment, would be deleted.

14 Condition F, would be revised to delete the reference to Mode 1, 2, and 3. Notes stating that 15 the SR is Only required to be met in MODES 1, 2, and 3, on SR 3.6.1.3.1, SR 3.6.1.3.2, 16 SR 3.6.1.3.7, SR 3.6.1.3.12, SR 3.6.1.3.13, SR 3.6.1.3.14, and SR 3.6.1.3.15 would also be 17 deleted.

18 19 The proposed changes are consistent with the approved TSs of plants that requested a 20 variation from TSTF-542 (e.g., Columbia Generating Station approval, ADAMS Accession 21 No. ML18255A350).

22 23 The NRC staff finds that the proposed changes to LCO 3.6.1.3 are acceptable because the 24 changes correctly specify the lowest functional capability or performance levels of equipment 25 required for safe operation of the facility in accordance with 10 CFR 50.36(c)(2)(i), since the 26 requirements for Shutdown Cooling Isolation instrumentation in Mode 4 and 5 was relocated by 27 the approval of TSTF-542. Additionally, the SR changes continue to assure that the necessary 28 quality of systems and components is maintained, that facility operation will be within safety 29 limits, and that the associated LCO will continue to be met in accordance with 10 CFR 30 50.36(c)(3). The NRC staff finds that the deletion of Conditions H and G and revision to 31 Condition F and deletion of the SR note are acceptable, because these items were only 32 applicable in Modes 4 and 5 consistent with the relocation of requirements approved in 33 TSTF-542.

34 35 3.6 Alternating Current Sources - Shutdown, STS 3.8.2 36 37 SR 3.8.2.1 requires the performance of the SRs in STS 3.8.1, AC Sources - Operating, with 38 some exceptions listed in SR 3.8.2.1 and its Notes 1 and 2. SR 3.8.2.1 would be revised to:

39

1) add SRs 3.8.1.11, 3.8.1.12, 3.8.1.13, and 3.8.1.19 to the list of exceptions; 2) modify Note 1; 40 and 3) delete Note 2.

41 42 The STS 3.8.2 Bases states that the LCO 3.8.2 ensures the capability of supporting systems 43 necessary for avoiding immediate difficulty in the event of an accident during shutdown 44 assuming either a loss of all offsite power or a loss of all onsite DG power. The operability of 45 the required offsite circuit and DG ensures the availability of sufficient AC sources to operate the 46 plant in a safe manner and to mitigate the consequences of postulated events (e.g., fuel 47 handling accidents (FHAs) involving recently irradiated fuel) during shutdown).

48 49 With the approval of TSTF-542, SR 3.8.1.12 verifies, in part, the automatic start of a DG on an 50 ECCS initiation signal. The DG starts automatically on an ECCS initiation signal for low reactor 51 vessel water level conditions in Operating Modes 1 through 3. This ECCS initiation signal also 1

starts certain ECCS equipment automatically. STS 3.5.2, Reactor Pressure Vessel Water 2

Inventory Control (RPV WIC), does not require automatic ECCS initiation to mitigate a draining 3

event in Modes 4 and 5, and the ECCS initiation signal related to the automatic ECCS initiation 4

is removed from the STS. Because the automatic ECCS initiation and related ECCS initial 5

signal in Modes 4 and 5 are eliminated, the automatic start of the DG on an ECCS initiation 6

signal is not required in Modes 4 and 5. The deletion of SR 3.8.2.12 was an inadvertent 7

omission from TSTF-542 changes. The NRC staff finds the deletion of SR 3.8.1.12 from 8

SR 3.8.2.1 is consistent with changes previously found acceptable in the SE approving 9

TSTF-542 and, therefore, acceptable.

10 11 SR 3.8.1.11 and SR 3.8.1.19 test, in part, the automatic start and loading of a DG on a LOOP 12 signal and a LOOP signal in conjunction with an ECCS initiation signal, respectively.

13 SR 3.8.1.13 verifies each DGs non-critical automatic trips are bypassed on actual or simulated 14 loss of voltage signal on the emergency bus concurrent with an actual or simulated ECCS 15 initiation signal. The DG non-critical trips are bypassed during an automatic DG start.

16 17 STS 3.5.2 considered a LOOP that can cause a draining event in Modes 4 and 5. If the Drain 18 Time decreases from 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> to< 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, then STS 3.5.2 Required Action D.1 requires that 19 an additional method of water injection be established to maintain required RPV water level and 20 that the ECCS injection/spray subsystem or the additional method of water injection be capable 21 to operate without offsite power. In addition, in a LOOP event, the STS 3.8.2 requires declaring 22 the affected required features inoperable. In this case, the affected instrumentation or ECCS 23 injection/spray subsystem in STS 3.5.2 will be declared inoperable and the applicable Actions 24 followed. If the required inoperable ECCS injection/spray subsystem cannot be restored to 25 operable status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, then STS 3.5.2 Required Action B.1 requires a method of water 26 injection capable to operate without offsite power.

27 28 The required DG must operate to supply power to the STS 3.5.2 water injection equipment that 29 is to operate without offsite power. Based on its review of the above-mentioned STS 3.5.2 30 Actions statements, the NRC staff finds that STS 3.5.2 provides enough time from the onset of 31 the LOOP event for the operator to manually start the DG required to supply power to the water 32 injection equipment to mitigate the draining event in Modes 4 and 5. In addition, STS 3.5.2 33 does not require the automatic initiation of the ECCS injection/spray subsystem or the additional 34 method of water injection. Therefore, since STS 3.5.2 allows enough time to manually start the 35 DG and the equipment for water injection, the NRC staff finds that the automatic start and 36 loading of the DG are not necessary on a LOOP signal or LOOP concurrent with an ECCS 37 initiation signal to mitigate a draining event in Modes 4 and 5.

38 39 Furthermore, the NRC staff notes that other events postulated in Modes 4 and 5 (e.g., FHA, 40 waste gas tank rupture) and during movement of [recently] irradiated fuel assemblies in the 41

[primary and secondary containment] do not assume a LOOP event or an automatic ECCS 42 initiation.

43 44 In summary, the NRC staff finds that since the DG automatic start is not required to mitigate the 45 consequences of postulated events (e.g., draining event, FHA) in shutdown conditions, testing 46 of the DG non-critical automatic trips bypass is not required to demonstrate the operability of the 47 DG during shutdown conditions. Therefore, the NRC staff finds that the proposed addition of 48 SR 3.8.1.11, SR 3.8.1.12, SR 3.8.13, and SR 3.8.1.19 to the list of SRs that are not applicable 49 for SR 3.8.2.1 is acceptable since testing of the DG automatic start and the bypass of DGs 50 non-critical automatic trips are no longer required to demonstrate the operability of the DG in 1

shutdown conditions.

2 3

Note 1 would be revised to delete SR 3.8.1.11, SR 3.8.1.13, and SR 3.8.1.19 from the list of 4

SRs that are not required to be performed to meet SR 3.8.2.1. As discussed above, it is 5

acceptable to remove these SRs from SR 3.8.2.1. Therefore, the NRC staff finds the deletion of 6

these SRs from Note 1 of SR 3.8.2.1 acceptable since testing of the DG automatic start and the 7

bypass of DGs non-critical automatic trips are no longer required to demonstrate the operability 8

of the DG in shutdown conditions.

9 10 Note 2 of the SR 3.8.2.1 states, SR 3.8.1.12 and SR 3.8.1.19 are not required to be met when 11 associated ECCS subsystem(s) are not required to be OPERABLE per LCO 3.5.2, 12 ECCS Shutdown. TSTF-582 proposed to delete Note 2 from the existing SR 3.8.2.1. Since 13 SR 3.8.1.12 and SR 3.8.1.19 will no longer apply to SR 3.8.2.1, the NRC staff finds the deletion 14 of Note 2 from the existing STS SR 3.8.2.1 acceptable since testing of the DG automatic start 15 and the bypass of DGs non-critical automatic trips are no longer required to demonstrate the 16 operability of the DG in shutdown conditions.

17 18 The NRC staff finds that the proposed changes to SR 3.8.2.1 are acceptable because the DG 19 automatic start is not required in Modes 4 and 5. Therefore, the NRC staff finds that the revised 20 SR 3.8.2.1 will continue to assure that the necessary quality of the onsite standby power 21 systems and components is maintained, that facility operation will be within safety limits, and 22 that the associated LCO 3.8.2 will be met in accordance with 10 CFR 50.36(c)(3).

23 24 3.7 Editorial Changes 25 26 The NRC staff finds that the proposed acronym changes in STS 3.5.2, SR 3.5.22, and 27 STS 3.5.1 are acceptable because they are editorial clarifications and do not substantively 28 change TS requirements.

29 30 3.8 Standard Technical Specification Bases 31 32 The Commissions Final Policy Statement on Technical Specifications Improvements for 33 Nuclear Power Reactors (Commissions Final Policy Statement), dated July 2, 1993 34 (58 FR 39132) provides the following description of the scope and the purpose of the STS 35 Bases:

36 37 Each LCO, Action, and Surveillance Requirement should have 38 supporting Bases. The Bases should at a minimum address the 39 following questions and cite references to appropriate licensing 40 documentation (e.g., Updated Final Safety Analysis Report 41 (FSAR), Topical Report) to support the Bases.

42 43

1. What is the justification for the Technical Specification, i.e.,

44 which Policy Statement criterion requires it to be in the Technical 45 Specifications?

46 47

2. What are the Bases for each LCO, i.e., why was it determined 48 to be the lowest functional capability or performance level for the 49 system or component in question necessary for safe operation of 50 the facility and, what are the reasons for the Applicability of the 51 LCO?

1 2

3. What are the Bases for each Action, i.e., why should this 3

remedial action be taken if the associated LCO cannot be met; 4

how does this Action relate to other Actions associated with the 5

LCO; and what justifies continued operation of the system or 6

component at the reduced state from the state specified in the 7

LCO for the allowed time period?

8 9

4. What are the Bases for each Safety Limit?

10 11

5. What are the Bases for each Surveillance Requirement and 12 Surveillance Frequency; i.e., what specific functional requirement 13 is the surveillance designed to verify? Why is this surveillance 14 necessary at the specified frequency to assure that the system or 15 component function is maintained, that facility operation will be 16 within the Safety Limits, and that the LCO will be met?

17 18 Note: In answering these questions the Bases for each number 19 (e.g., Allowable Value, Response Time, Completion Time, 20 Surveillance Frequency), state, condition, and definition (e.g.,

21 operability) should be clearly specified. As an example, a number 22 might be based on engineering judgment, past experience, or 23 PSA insights; but this should be clearly stated.

24 25 TSTF-582 proposed that a new Action A.1 be added to the Reactor Pressure Vessel Water 26 Inventory Control Instrumentation, STS 3.3.5.2 Actions. The NRC staff determined the 27 proposed STS Bases for Action A.1 describes why this remedial action should be taken if the 28 associated LCO cannot be met, that it relates to other Actions associated with the LCO, and 29 provides justification for continued operation of the system or component at the reduced state 30 from the state specified in the LCO for the allowed time period. The STS Bases explain that the 31 licensee should take immediate action to place the channel in trip when the LCO is not met 32 because the remaining channel will isolate the penetration flow path on low water level. The 33 STS Bases explain that taking immediate action to place the channel in trip relates to 34 immediately declaring the associated flow path(s) incapable of automatic isolation and 35 immediately initiating action to calculate the drain time, because the calculation cannot credit 36 automatic isolation of the affected penetration flow paths. The STS Bases further explain that 37 even though the LCO 3.3.5.2 is not met, the plant can continue to operate in Modes 1, 2, or 3 38 for six hours because there are appropriate compensatory measures for separate Condition 39 entry for each inoperable RPV Water Inventory Control instrumentation channel.

40 41 The other proposed changes would delete or revise the STS Bases consistent with the 42 associated proposed LCO and SR changes and correct typographical errors. The NRC staff 43 finds that the proposed STS Bases deletions are appropriate to reflect the proposed deletions to 44 the LCOs and SRs that are no longer applicable after adoption of TSTF-542. TSTF-542 deleted 45 Operations with a Potential for Draining the Reactor Vessel (OPDRVs). Therefore, information 46 on OPDRVs are not needed. In addition, the correction of typographical errors improves the 47 clarity of the STS Bases. Therefore, the NRC staff finds that the proposed revisions to the STS 48 Bases are consistent with the Commissions Final Policy Statement and 10 CFR 50.36.

49 50

4.0 CONCLUSION

1 2

The NRC staff finds that proposed changes to STS 1.1 Definition and LCOs 3.3.5.2, 3.3.6.1, 3

3.5.2, and 3.6.1.3 correctly specify the lowest functional capability or performance levels of 4

equipment required for safe operation of the facility in accordance with 10 CFR 50.36(c)(2)(i).

5 Also, the NRC staff finds that proposed changes to the Action of LCOs 3.3.5.2A, 3.3.5.2B, and 6

3.6.13 are adequate remedial actions to be taken until each LCO can be met provide protection 7

to the health and safety of the public, thereby satisfying 10 CFR 50.36(c)(2)(i).

8 9

The NRC staff finds that the proposed revisions to SRs 3.3.5.2, 3.5.2, 3.6.1.3, and 3.8.2 10 continue to provide requirements relating to test, calibration, or inspection to assure that the 11 necessary quality of systems and components is maintained, that facility operation will be within 12 safety limits, and that the LCOs will be met in accordance with 10 CFR 50.36(c)(3).

13 Accordingly, the NRC staff finds TSTF-582 changes acceptable.

14 15 Principal Reviewers: Tarico Sweat, NRR/DSS/STSB 16 Gursharan Singh, NRR/DE/EICB 17 Khadijah West, NRR/DE/EICB (prior to joining NRR/DSS/STSB) 18 Adakou Foli, NRR/DE/EEOB 19 Larry Wheeler, NRR/DSS/SCVB 20 21 Date: July 29, 2020 22