05000325/LER-1979-018-03, /03X-1 on 790414:main Steam Relief Valve 1B21-F013J Opened at 520 Psi During Plant Startup.Valve Immediately Reseated.Possible Cause May Be Excessive Pilot or Second Stage Seat Leakage

From kanterella
(Redirected from ML19261D894)
Jump to navigation Jump to search
/03X-1 on 790414:main Steam Relief Valve 1B21-F013J Opened at 520 Psi During Plant Startup.Valve Immediately Reseated.Possible Cause May Be Excessive Pilot or Second Stage Seat Leakage
ML19261D894
Person / Time
Site: Brunswick 
Issue date: 06/26/1979
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19261D893 List:
References
LER-79-018-03X, LER-79-18-3X, NUDOCS 7906280088
Download: ML19261D894 (2)


LER-1979-018, /03X-1 on 790414:main Steam Relief Valve 1B21-F013J Opened at 520 Psi During Plant Startup.Valve Immediately Reseated.Possible Cause May Be Excessive Pilot or Second Stage Seat Leakage
Event date:
Report date:
3251979018R03 - NRC Website

text

h J O U

5 J7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFoRMATION) 1 6

M l N l C l B l E l P l 1 l@l 0 l 0 l - l 0 l 0 0 l 0 l 0 l IO l 0 l@!4 l1 l 1l1 l1 l@l 7

8 9 LICENSEE CODE 14 15 Lir NSE NUMBER 25 26 LICENSE TYPE JO 57 CAT 58 CON'T

"'[n"C l L j@l 0 l 5 l 0 l - l 0 l 3 l 2 l 5 @l 014 l1 l 4 l 7 l 9 l@l 0l6l2 6l 7 9lg o

1 3o 7

8 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h o

2 lDurine olant start-uo and nrosettri>neinn fn11nuing, vafitaling nitenga

,,4n acanm va-o 3

l lief valve 1B21-F013J. opened at 520 osi and immediate1v reseated. The setpoint for 1

O 4

Ithis valve is 1125 osi t 1%.

The result of this event was a reactor scen, dita en n 0

5 l high flux spike on the IRM's.

I O

6 I (Technical Specifications 6.9.2.9b) l O

7 l

l 0

8 l

l 7

8 9 80 SYSTEM

CAUSE

CAUSE COMP.

VALVE CODE CODE SUSCODE COMPONENT CODE SU8 CODE SUSCODE l C l C l@ lE l@ lB l@ l V Al Ll Vl 0l Pl@

Jl@ W @

O 9

7 8

9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION LER/RO EVENT YEAR R EPORT NO.

CODE TYPE NO.

@ REPORT l 7l 9l

_l l 0l 1 8[

l,,,, -

0[3l lX l l_

l 1l 21 22 23 24 26 27 28 29 30 31 32 T KN A ON O PL NT M

HOURS 22 S 8 I FOR b 8.

SUPPLIE MANUFACTURER lBlgl34Z lg l35 Clg l6C lg j 0l 0l 4l l

lY g l Y l g l Nl g lT l0 l2 l0 lg 33 3

37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h lThe valve actuator was removed and sent to Wyle Laboratories for repair by Target-Rock 4 i

o gg Target-Rock attempted to determine the set pressure of the actuator, but could not dueI g lto excessive pilot leakage. The actuator was disassembled and the pilot disc, second l l stage disc, pilot seat, and second stage seat were all found to be steam cut. While l

,i 3

lno specific reason was found for the valve to open at 520 psi, it is suspected (Con't) i 4

7 8 9 80 ST S

% POWER O THER STATUS DIS O RY DISCOVERY DESCRIPTION l C [@ l 0l 0[ 0l@l NA l

l Al@l Reactor Scram l

i s

ACTIVITY CO TENT RELEASE @D OF RELEASE lZ lg[NA l

l NA l

AMOUNT OF ACTIVITY LOCATION OF RELEASE lZl 1

6 7

8 9 10 11 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE

DESCRIPTION

l0]0l0l@lZl@l HA l

1 7

PERSONNEL INJURIES NUMBER

DESCRIPTION

1010101@l NA

??im 022 i

i a

7 8 9 11 12 80 LOSS OF OR OAMAGE TO FACILITY 7006280off g "fEg 3

DESCRIMlON 7

d 0 10 go isSuEo@OESCRIPTION e

lNj l

NA ll l

lllll llj 2

O 7

8 9 10 68 69 80 7.

NAME OF PREPARER

LER CONTINUATION -- RO# 1-79-018 Facility:

BSEP Unit #1 Event Date:

4-14-79 that excessive pilot and/or second stage seat leakage contributed to the leakage. The pilot and second stage seats and discs were resu-faced. The actuator was reassembled, tested, and reset to 1125 psi. Valve testing will continue in accordance with ISI : c quirements.

2210 023