05000325/LER-1979-095-03, /03L-0:on 791106,Units 1 & 2 Chlorine Detectors Failed to Respond to Test Solution.Cause Not Known.Plant Chlorine Source Moved Outside Exclusion Area Until Detectors Repaired

From kanterella
(Redirected from ML19210E653)
Jump to navigation Jump to search
/03L-0:on 791106,Units 1 & 2 Chlorine Detectors Failed to Respond to Test Solution.Cause Not Known.Plant Chlorine Source Moved Outside Exclusion Area Until Detectors Repaired
ML19210E653
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 11/28/1979
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19210E649 List:
References
LER-79-095-03L, LER-79-95-3L, NUDOCS 7912050470
Download: ML19210E653 (1)


LER-1979-095, /03L-0:on 791106,Units 1 & 2 Chlorine Detectors Failed to Respond to Test Solution.Cause Not Known.Plant Chlorine Source Moved Outside Exclusion Area Until Detectors Repaired
Event date:
Report date:
3251979095R03 - NRC Website

text

(7 77)

LICENSEE EVENT REPORT g

  1. aROt stOCic: p I I

I I I j@

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 0 l010 l-l010 l@!4 il l1 l1 l1 l@l l@

Io ITl I N I C l B l E I P l 1 l@l 0 l o l-l 0 0

7 8 9 UCENSEE CODE le 16 LsCENSE NuMsEH 25 26 LICENSE TYPE Jo 57 CA1 58 CON'T

.0%

t.l@iO s 10 l-10 312 i s l@l11110161719 l@l I

l I

I I

l@

O i

7 3

60 6t DOCKET NUM8ER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEOUENCES h o 2 l While performing PT 46.3PC. Control Buildinst Chlorine Detector Check. neither Unit l

[oTil l 1 nor Unit 2 chlorine detectors 1(2)X-AT-2977, would respond to the test solution.

l l

Lo_lij l MI l

I o 6 EI I

o a

Technical Specification 3.3.5.5, 6.9.1.9b I

E CODE

$ SC E COMPONENT CODE SUSCOdE SU E

l S l G l@ y@ W@ l I Nl Sl Tl Rl Ul@ W@ W @

o 9 7

8 9

10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION LER/RO EVENT YEAR REPORT NO.

CODE TYPE N O.

@,atgr 71 91 l---J l 01 9 si M

I nl il ItI l-l I01 u

,, 21 22 23 24 26 27 28 29 30 31 32 T%N AC O O PL NT MET HOURS S8 i FOR 8.

SUPPLIE MANUFAC RER lXl@lXl@

y@

l Zl@

l 0l 0l 0 01 J@

l Y l@

l Al@

lW 0 l 2 l 5 l@

33 34 35 36 37 40 43 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h

!i o lThe instruments were calibrated and still would,not respond.

A technical represents-1 i i itiva has been requested from the manufacturer to assist in the troubleshooting and -e-I i 2 l Pair of these instruments. The plant chlorine source has been moved outside the ex-lTTi] l clusion area until the chlorine detectors are repaired.

I U_14_l l 7

8 9 80 SA S

% POWER OTHE R STA TUS I O RY DISCOVERY DESCIUPTION [TTT1 I c l@ l0 l010 l@l N/A l

lB l@l Periodic Test I

ACTIVITY CO TENT RELEASED cF RELE ASE AMOUNT OF ACTivlTY LOCATION CF RELEASE

@ (Z_j @ l N/A l N/A l

i 6

7 8 9 10 1:

44 45 80 PERSONNEL EXPC3URES NUMRE R TYPE D E SCRIPTION l0l0l0l@lZl@] N/A I

i 7

PERSON ~Etl N,a5 1497 22 oESCRiPriON@

NuMRER R l0l0 0l@lN/A

~

l 7

d 9 11 12 80 LOSS OF OR OAMAGE,0~TO F ACILITY ^43U 7912050 j

ivPE oESCRi,1 fiTo,,IZl@lN/A 7

8 9 10 80 g S$df @l ESCRIPrlON N/A l lllllllllll l l%L 7

8 9 10 68 69 80 3 on, h.

~

~

UME OF PREPARER PHONE: