05000325/LER-1979-088-03, /03L-0:on 791025,HPCI Injection Valve F006 Could Not Be Operated from Rtgb.Caused by Misplaced Drive Gear Key Due to Missing Lockwire in Drive Gear.Operator Reassembled Correctly & Tested.Cause for Missing Lockwire Unknown

From kanterella
(Redirected from ML19210D270)
Jump to navigation Jump to search
/03L-0:on 791025,HPCI Injection Valve F006 Could Not Be Operated from Rtgb.Caused by Misplaced Drive Gear Key Due to Missing Lockwire in Drive Gear.Operator Reassembled Correctly & Tested.Cause for Missing Lockwire Unknown
ML19210D270
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 11/19/1979
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19210D267 List:
References
LER-79-088-03L, LER-79-88-3L, NUDOCS 7911260216
Download: ML19210D270 (2)


LER-1979-088, /03L-0:on 791025,HPCI Injection Valve F006 Could Not Be Operated from Rtgb.Caused by Misplaced Drive Gear Key Due to Missing Lockwire in Drive Gear.Operator Reassembled Correctly & Tested.Cause for Missing Lockwire Unknown
Event date:
Report date:
3251979088R03 - NRC Website

text

u. s. nucLeart estuutn e vn v Luwvissaavre NRC FORM 366 (7-77) y

=

LICENSEE EVENT REPORT CONTROL BLOCK:

l l

l l

l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

lNlClBlElPl1l@l0l0l-l0 0 l 0 l 0 l 0 l-l 0 l 0 l@l 4 l 1 l 1 l 1 l 1 l@l l

l@

o 1

7 8 9 LICENSEE CGDE 14 15 LICENSE NuMSEM 26 46 L6 CENSE TYPE JO 51 CA T Sd CON'T 3[C"7 L}@l0l5l0l-l0l3l2l5 @l1l0l2l5l7l9 @

l l

l l

l l@

o i

,c F

8 60 61 DOCK ET NUMS E R bd 69 EVENT DATE 14 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h El While performing PT 9.2, HPCI System Component Test, the control operator noticed l

that the HPCI injection valve F006 could not be operated from the RTGB.

o 3 l I

o d

l I

L o

s I

I o I c l I, l

o 7ll o

a l Technical Specification 3.5.1, 6.9.1.9b 80 7

8 9 S$EE Co'oE SuSC$$E COMPONENT Co0E SUB E

S E

^*

S j Fl@ lE l@ l B l@ l Vl Al Ll Vl 0l P @ g@ l z l@

O 9 7

8 9

10 11 12 13 18 19 20 SEoUENTIAL OCCURRENCE REPORT REvtSION LER Ro EVENT YE AR REPORT NO.

CODE TYPE No.

h yo l 7l 9l l-l l0 8l 8l l/l 10l3l Lj l-l l0l RE AT

_ 21 22 23 24 26 27 M

23 30 31 32 TK N A TO O PL NT VET HOURS SS 8 FC b S.

SL P* LIE R MANUFACTURER l B l@l Z l@

[J_j@

[2_j@

l0l0 010l [y_j @

Yl@

lNl@

l 1, l 2 l 0 l 0 l@

33 34 25 26 31 40 48 42 43 44 47 cAUSE DESCRIPTION AND CORRECTIVE ACTIONS h An investigation of the valve operator determined that lockwire was missing from l

i o

i i

l the drive gear with resultant loosening of the set screw which allowed the drive i

g*

gear key to come out of its keyway. The operator was reassembled correctly and l

gl tested. No reason could be determined for the missing lockwire. (Cont'd) l L'_L*.J l 80 7

8 9 h

STA S

% POWER oTHER STATUS blS o RY DISCOVERY DESCRIPTION J@ l0 5 l 0 l@l N/Al l B l@[ Periodic Test l

i s

i M

4 80 Co' TENT A TIVITY RELE ASED OF RELEASE AMOUNT oF ACTIVITY LOCATION oF RELEASE l,,1, [,6,,.] [Z,,j h [,,Z,,.j@l N/Al N/A l

PEnSoNNEt ExPoSOES oEsCRiPTioNh 17q1 i0 i

NUveER TvPE fiTTl l 0l 0I Ol@l Z l@l N/A

' ' I I

Ps RSoNNE L INJURIES Q

3 NU YR E R CESCRIPTioN l

y l0l0lOl@l N/A oo c

m 80 7

8 9 11 12

'?vn ' " ^C, PVo'N '' " @

7911260 2 / 6

"^

W @l N/A i 9 7

il 3 to go issue @oESCRieTioNh NRC USE ONLY l

N/A l

llll1llllllll}

2 o 68 69 80 5 8 9 10 WAME OF PREPARER PHONE.

LER CONTINUATION - RO# l-79-88 Facility:

BSEP Unit No. 1 Event Date:

10-25-79 There is no record of previous corrective maintenance on this operator. The maintenance instruction cove. ring reassembly of the subject components was recently cevised proviuing detailed instructions on reassembly. This is con-sidered an isolated event.

1TQ) jj}

lO

n 96