/.777 -

LICENSEE EVENT REPORT CONTROL BLOCK: l l l l l l l (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6 7

0 1!

8 9 N lC lB lE lP l1 l@l 0l 0l -l 010l 0l 0l 0l -l 0 0@l4LICENSE LICENSEE CODE 14 15 LICENSE NUMBER 25 26 1l1l1!1 TYPE JO

@l57 C Al T 58l@

CON'T L @ 0 l5 l0 l- 10 l3 l2 l568 l@l 0 l 7 l Il 9l 7 9g 0 8l1l5l7l980 g 0 1 SO7RCE 7 8 60 61 DOCK ET NUMB E R 69 EVENT DATE 14 75 REPORT DATE EVENT DESCRIPT'ON AND PROBABLE CONSEQUENCES h o 2 lWhile oerforming a normal reactor startup. the following indicating problems were noted:

o a 11) " Full-in" indication remained on after rod 10-23 had been pulled; 2) No indication l 0 4 lof " Full-in" on rod 42-11; 3) a " Full-in" signal was not being provided to the rod j 0 s l control circuitry (RSCS) by rod 22-11. l 0 6 l Technical Specification 3.1.5.7, 6.9.1.9b l 0 I l l o a I I 7 3 9 80 SYSTEM CAUSE CAUSE COMP. VALVE CODE CODE SUSCODE COVPONENT CODE SUSCOCE SU8COOE 7

o 3 8

lRlBj@ E l@ lG l@

3 10 IlNlSlT R l Uj@ l I l@ l Zl @

11 12 13 18 19 20

_ SEQUENTI AL OCCURRENCE REPORT REVISION LER PO EVENT YE AR REPORT NO. CODE TYPE NO.

O g g,R; I719l 21 22 l-l 23 l0 I4 17 24 I/I lnl1l d -l W 26 27 28 29 30 31 32 T K5 A ON ON PLA T T HOURS S 8 lTT D FOR b B. S PPLIE MAN FAC URER lA JJ l@J4 l@

Z lZ 35 l@ lZ l@ l0 37 0 0l 0l l41 Yl@ l42Y ]@ l43N l@ l Ml 4 5 l 5 l@

36 40 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 1 o lA bad IC chip was found on the rod 10-23 probe buf fer card. This card was replaced It til Ifrom stock. While attempting to replace the bulbs in the " Full-in/ Full-out" indicatori i ,

Ifor rod 42-11, the socket was broken. The socket was replaced from stock. The " Full- l 1 i in" logic signal is fed through a light isolator, a probe card, and on to the RSCS l 1 4 Ilogic board. The light isolator was found burned out, which prevented (Con't) l 3 9 80 STA 5 %PuWER OTHER STATUS ISCOV RY DtSCOVERY DESCRIPTION 1 5 [_C.j h l 0 l 0 0lhl NA l [_A_j@l Operator Surveillance l ACTivlTY CO TENT RELEASED OF RELE ASE AMOUNT OF ACTIVITY LOCA1 '.,* ' OF PE L E ASE i 6 7 3 3

[3] @ W @ l NA 10 11 44 l NA 45 l

  1. EnSONNE L E xpOSURES 80 NUMBER TYPE DWRIPTICN 1 7 l 0l 0 0l@lZl@l' NA l PwSONNe'L% J ,eS
  • NuveER DESCRIPTION @

i 1010101@l NA l

7 8 9 .

80 LOSSCF: O FACILITY 43 - --

/

Type .n t L F. > *'ON '

][

M l dZ9 l@l NA

/ to

- t /

go DESCRIPTION -'F -

e

^

rn 1 a'SSUE]8l 1 9 Ln NA l i lllllllll lll}

10 68 69 80 5 NAitE OF PREPARER A. C. Tollison, Jr. PHONE 919-457-9521 2,