Figure: 25 TAC §289.252(jj)(2)
(2)
Isotope quantities (for use in subsection (gg) of this section).
RADIONUCLIDES Limit Unsealed Sources Sealed Sources 103 104 105 1010 1012 Pr-141 Gd-152 Bi-209m U-232 Pu-240 Cm-245 Cf-252 Ce-142 Dy-154 Po-208 U-233 Pu-241 Cm-246 Es-254 Nd-144 Dy-156 Po-209 U-234 Pu-242 Cm-247 Nd-145 Tb-159 Po-210 U-235 Pu-244 Cm-248 Sm-146 Ho-165 Ra-226 U-236 Am-241 Bk-247 Sm-147 Hf-174 Ac-227 Np-235 Am-242m Bk-249 Sm-148 W-180 Th-228 Np-237 Am-243 Cf-248 Gd-148 Pt-190 Th-229 Pu-236 Cm-242 Cf-249 Gd-150 Pb-210 Th-230 Pu-238 Cm-243 Cf-250 Gd-151 Bi-209 Pa-231 Pu-239 Cm-244 Cf-251 0.01
µCi 0.01 mCi 0.1 mCi 1.0 mCi 100 Ci 10 kCi and any alpha-emitting radionuclide not listed above or mixtures of unknown alpha emitters of unknown composition.
Be-10 Fe-60 Rh-102 Te-123 Sm-145 Lu-175 Ir-199m Al-26 Zn-70 Pd-107 Te-130 Nd-150 Lu-176 Pt-192 Si-32 Ge-68 Ag-108m I-129 Eu-150 Lu-177m Pt-198 Ar-39 Ge-76 Cd-113m La-137 Tb-157 Hf-172 Hg-194 K-40 Kr-81 Cd-116 La-138 Tb-158 Hf-182 Pb-202 Ar-42 Sr-90 Sn-121m Ce-139 Dy-159 Ta-179 Pb-205 Ca-48 Zr-96 Sn-123 Pm-143 Ho-166m Re-184m Bi-208 Ti-44 Mo-100 Sn-124 Pm-144 Lu-173 Re-187 Ra-228 V-49 Tc-98 Sn-126 Pm-145 Lu-174 Re-189 Np-236 V-50 Rh-101 Te-121m Pm-146 Lu-174m Os-194 Bk-248 0.1
µCi 0.1 mCi 1.0 mCi 10 mCi 1.0 kCi 100 kCi and any other alpha-emitting radionuclides not listed above or mixtures of beta emitters of unknown composition.
Na-22 Ru-106 Cs-134 Eu-152 Bi-210 U (natural)
Co-60 Ag-110m Ce-144 Eu-154 Th (natural) 1.0
µCi 1.0 mCi 10 mCi 100 mCi 10 kCi 1 MCi Cl-36 Ni-63 Rb-87 Cd-109 Ba-133 Gd-153 Tm-171 Ca-45 Zn-65 Zr-93 In-115 Ba-135 Eu-155 W-181 Mn-54 Se-75 Nb-93m Sb-125 Cs-137 Tm-170 Tl-204 10
µCi 10 mCi 100 mCi 1.0 Ci 100 kCi 10 MCi C-14, Co-57 Kr-85 Tc-99 Ir-194 U-238 Fe-55 Ni-59 Tc-97 Pt-193, Th-232 100
µCi 100 mCi 1.0 Ci 10 Ci 1.0MCi 100 MCi H-3 1.0 mCi 1 Ci 10 Ci 100 Ci 10 MCi 1000 MCi
Figure: 25 TAC §289.252(jj)(7)
Radioactive Material*
Release Fraction Quantity (curies)
Radioactive Material*
Release Fraction Quantity (curies)
Radioactive Material*
Release Fraction Quantity (curies)
Ac-228 (89) 0.001 4,000 In-114m (49) 0.01 1,000 V-48 (23) 0.01 7,000 Am-241 (95) 0.001 2
Ir-192 (77) 0.001 40,000 Xe-133 (54) 1.0 900,000 Am-242 (95) 0.001 2
Fe-55 (26) 0.01 40,000 Y-91 (39) 0.01 2,000 Am-243 (95) 0.001 2
Fe-59 (26) 0.01 7,000 Zn-65 (30) 0.01 5,000 Sb-124 (51) 0.01 4,000 Kr-85 (36) 1.0 6,000,000 Zr-93 (40) 0.01 400 Sb-126 (51) 0.01 6,000 Pb-210 (82) 0.01 8
Zr-95 (40) 0.01 5,000 Ba-133 (56) 0.01 10,000 Mn-56 (25) 0.01 60,000 Any other Ba-140 (56) 0.01 30,000 Hg-203 (80) 0.01 10,000
- emitter 0.01 10,000 Bi-207 (83) 0.01 5,000 Mo-99 (42) 0.01 30,000 Mixed fission Bi-210 (83) 0.01 600 Np-237 (93) 0.001 2
products 0.01 1,000 Cd-109 (48) 0.01 1,000 Ni-63 (28) 0.01 20,000 Mixed Cd-113 (48) 0.01 80 Nb-94 (41) 0.01 300 corrosion Ca-45 (20) 0.01 20,000 P-32 (15) 0.5 100 products 0.01 10,000 Cf-252 (98) 0.001 9(20mg)
P-33 (15) 0.5 1,000 Contaminated C-14 (6)**
0.01 50,000 Po-210 (84) 0.01 10 equipment, Ce-141 (58) 0.01 10,000 K-42 (19) 0.01 9,000 0.001 10,000 Ce-144 (58) 0.01 300 Pm-145 (61) 0.01 4,000 Irradiated Cs-134 (55) 0.01 2,000 Pm-147 (61) 0.01 4,000 material, Cs-137 (55) 0.01 3,000 Ra-226 (88) 0.001 100 any form Cl-36 (17) 0.5 100 Ru-106 (44) 0.01 200 other than Cr-51 (24) 0.01 300,000 Sm-151 (62) 0.01 4,000 solid non-Co-60 (27) 0.001 5,000 Sc-46 (21) 0.01 3,000 combustible 0.01 1,000 Cu-64 (29) 0.01 200,000 Se-75 (34) 0.01 10,000 Irradiated Cm-242 (96) 0.001 60 Ag-110m (47) 0.01 1,000 material, Cm-243 (96) 0.001 3
Na-22 (11) 0.01 9,000 solid non-Cm-244 (96) 0.001 4
Na-24 (11) 0.01 10,000 combustible 0.001 10,000 Cm-245 (96) 0.001 2
Sr-89 (38) 0.01 3,000 Mixed Eu-152 (63) 0.01 500 Sr-90 (38) 0.01 90 radioactive Eu-154 (63) 0.01 400 S-35 (16) 0.5 900 waste, -
0.01 1,000 Eu-155 (63) 0.01 3,000 Tc-99 (43) 0.01 10,000 Packaged Ge-68 (32) 0.01 2,000 Tc-99m (43) 0.01 400,000 waste, Gd-153 (64) 0.01 5,000 Te-127m(52) 0.01 5,000 Au-198 (79) 0.01 30,000 Te-129m(52) 0.01 5,000 0.001 10,000 Hf-172 (72) 0.01 400 Tb-160 (65) 0.01 4,000 Any other Hf-181 (72) 0.01 7,000 Tm-170 (69) 0.01 4,000 emitter 0.001 2
Ho-166 (67) 0.01 100 Sn-113 (50) 0.01 10,000 Contaminated H-3 (1) 0.5 20,000 Sn-123 (50) 0.01 3,000 equipment 0.0001 20 I-125 (53) 0.5 10 Sn-126 (50) 0.01 1,000 Packaged I-131 (53) 0.5 10 Ti-44 (22) 0.01 100 waste ***
0.0001 20
Figure: 25 TAC §289.252(jj)(7)
For combinations of radionuclides, consideration of the need for an emergency plan is required if the sum of the ratios of the quantity of each radionuclide authorized to the quantity listed for that radionuclide in this paragraph exceeds one. ( ) indicates atomic number.
Non CO forms only.
Waste packaged in Type B containers does not require an emergency plan.
Figure: 25 TAC §289.253(ee)(3)
CAUTION ONE 2 CURIE CS 137 RADIOACTIVE SOURCE ABANDONED 3-3-75 AT 8400 FT. PLUG BACK DEPTH 8200 FT.
DO NOT RE-ENTER THIS WELL BEFORE CONTACTING RADIATION CONTROL TEXAS DEPARTMENT OF STATE HEALTH SERVICES X.Y.Z. OIL COMPANY UNIVERSITY NO. 1234
Figure: 25 TAC §289.253(ee)(5)
Name of Record/Document Rule Cross-Reference (this section unless otherwise noted)
Time Interval for Keeping Record/Document (A)
(B)
(C)
(D)
(E)
(F)
(G)
(H)
(I)
(J)
(K)
(L)
(M)
(N)
(O)
(P)
Inspection records Agreement with well operator, owner, drilling contractor, or land owner Survey instrument calibration Leak test Quarterly inventory Utilization record Certification document Inspection and maintenance Training and Testing Current operating, safety, and emergency procedures Personnel monitoring Radiation surveys Current License or Certificate of Registration Receipt, transfer, and disposal Shipping papers for transportation Current 25 TAC §289.253 of this title and other applicable sections as listed in the license or certificate of registration (d)(4)
(e)
(i)
(j)
(k)
(l)
(m)
(o)
(p)
(q)
(r)
(bb)
(cc)
(cc) 3 years after each annual internal inspection 5 years following completion of the well logging service operation or tracer study 3 years 3 years 3 years 3 years 3 years 3 years 3 years after employee terminates employment with the licensee or registrant Until termination of license or certificate of registration Until disposal is authorized by the agency 3 years after completion of the survey Until termination of license or certificate of registration Until disposal is authorized by the agency 3 years Until termination of license or certificate of registration
Rule Cross Reference Name of Records/Documents Time Interval for Keeping Records/Documents
Records of receipt, transfer, and disposal of radioactive material Until disposal is authorized by the agency
§289.202(bbb)
Records of leak tests for specific devices and sealed sources 3 years
Current applicable sections of this chapter as listed in the radioactive material license Until termination of the radioactive material license
Copy of the current radioactive material license Until termination of the radioactive material license
Current operating, safety, and emergency procedures Until termination of the radioactive material license
Qualifications of RSO Duration of employment
Qualifications of authorized users Duration of employment
§289.256(f)(3)(C)(iii)
Qualifications of authorized medical physicist Duration of employment
Qualifications of authorized nuclear pharmacist, if applicable Duration of employment
Authority of RSO Duration of employment
Qualifications and dates of service for temporary RSO 3 years
RSC meetings 3 years
Written directives 3 years
Procedures for administrations requiring a written directive Until termination of the radioactive material license
Calibration of instruments (dose calibrators) 3 years
Calibration of survey instruments 3 years
Dosage determinations of unsealed radioactive material for medical use 3 years
Physical inventory for all sealed source/brachytherapy inventory 3 years
§289.256(bb)(3)
Surveys for ambient radiation exposure rate 3 years
§289.256(cc)(3)
§289.256(eee)(2)
Patient release 3 years after date of release
§289.256(dd)(3)
Mobile nuclear medicine service client letters Duration of licensee/client relationship
§289.256(dd)(3)
Mobile nuclear medicine service surveys 3 years
§289.256(ee)(2)
Decay in storage/disposal 3 years
§289.256(ii)(4)
Molybdenum-99 concentrations 3 years
§289.256(ll)(2)
Safety instructions - unsealed radioactive materials 3 years
Rule Cross Reference Name of Records/Documents Time Interval for Keeping Records/Documents
§289.256(ss)(3)
Surveys after sealed source implant and removal 3 years
§289.256(tt)(3)
Brachytherapy sealed sources accountability 3 years
§289.256(uu)(2)
Safety instructions - brachytherapy 3 years
§289.256(ww)(4)
Calibration measurements of brachytherapy sealed sources 3 years
§289.256(xx)(2)
Strontium 90 activity of source Duration of life of source
§289.256(bbb)(2)
Service provider documentation 3 years
§289.256(fff)(4)
Installation, maintenance, adjustment and repair-remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units 3 years
Dosimetry equipment calibration, intercomparison and comparison Until termination of the radioactive material license
§289.256(jjj)(7)
Calibration - teletherapy units 3 years
§289.256(kkk)(9)
Calibration - remote afterloader units 3 years
§289.256(lll)(7)
Calibration - gamma stereotactic radiosurgery units 3 years
§289.256(mmm)(2)
Written procedures for spot checks-teletherapy units Until licensee no longer possesses unit
§289.256(mmm)(6)
Spot checks-teletherapy units Until licensee no longer possesses unit
§289.256(nnn)(2)
Written procedures for spot checks -
remote afterloaders 3 years
§289.256(nnn)(6)
Spot checks-remote afterloader 3 years
§289.256(ooo)(2)
Written procedures for spot checks-gamma stereotactic radiosurgery units 3 years
§289.256(ooo)(8)
Spot checks-gamma stereotactic radiosurgery units 3 years
§289.256(ppp)(5)
Technical requirements for mobile remote afterloader units 3 years
§289.256(qqq)(3)
Radiation surveys Duration of the use of the unit
§289.256(rrr)(3)
Five-year inspection for teletherapy and gamma stereotactic radiosurgery units Duration of the use of the unit
§289.256(uuu)(9)
Annotated report - medical event Until termination of the radioactive material license
Annotated report - dose to embryo/fetus or nursing child Until termination of the radioactive material license
Figure: 25 TAC §289.257(ee)(4)(A) 1 (i)
A B(i) 1 i
where B(i) is the activity of radionuclide i, and A1(i) is the A1 value for radionuclide i.
Figure: 25 TAC §289.257(ee)(4)(B) 1 (i)
A B(i) 2 i
where B(i) is the activity of radionuclide i in normal form and A2(i) is the A2 value for radionuclide i.
Figure: 25 TAC §289.257(ee)(4)(C) where B(i) is the activity of radionuclide i as special form radioactive material, A1(i) is the A1 value for radionuclide i, C(j) is the activity of radionuclide j as normal form radioactive material, and A2(j) is the A2 value for radionuclide j.
Figure: 25 TAC §289.257(ee)(4)(D)
(i)
A f(i) 1
=
mixture for A
1 i
1
where f(i) is the fraction of activity of radionuclide i in the mixture and A1(i) is the appropriate A1 value for radionuclide i.
Figure: 25 TAC §289.257(ee)(4)(E)
(i)
A f(i) 1
=
mixture for A
2 i
2
where f(i) is the fraction of activity of radionuclide i in the mixture and A2(i) is the appropriate A2 value for radionuclide i.
Figure: 25 TAC §289.257(ee)(4)(F)
Exempt activity concentration for mixture (i)
A f(i) 1
=
i
]
[
where f(i) is the fraction of activity concentration of radionuclide i in the mixture, and [A](i) is the activity concentration for exempt material containing radionuclide i.
Figure: 25 TAC §289.257(ee)(4)(G)
Exempt consignment activity limit for mixture (i)
A f(i) 1
=
i
where f(i) is the fraction of activity of radionuclide i in the mixture, and A is the activity limit for exempt consignments for radionuclide i.
Figure: 25 TAC §289.257(ee)(6)
Table 257 A1 and A2 Values for Radionuclides Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Ac-225 (a)
Actinium (89) 8.0X10-1 2.2X101 6.0X10-3 1.6X10-1 2.1X103 5.8X104 Ac-227 (a) 9.0X10-1 2.4X101 9.0X10-5 2.4X10-3 2.7 7.2X101 Ac-228 6.0X10-1 1.6X101 5.0X10-1 1.4X101 8.4X104 2.2X106 Ag-105 Silver (47) 2.0 5.4X101 2.0 5.4X101 1.1X103 3.0X104 Ag-108m (a) 7.0X10-1 1.9X101 7.0X10-1 1.9X101 9.7X10-1 2.6X101 Ag-110m (a) 4.0X10-1 1.1X101 4.0X10-1 1.1X101 1.8X102 4.7X103 Ag-111 2.0 5.4X101 6.0X10-1 1.6X101 5.8X103 1.6X105 Al-26 Aluminum (13) 1.0X10-1 2.7 1.0X10-1 2.7 7.0X10-4 1.9X10-2 Am-241 Americium (95) 1.0X101 2.7X102 1.0X10-3 2.7X10-2 1.3X10-1 3.4 Am-242m (a) 1.0X101 2.7X102 1.0X10-3 2.7X10-2 3.6X10-1 1.0X101 Am-243 (a) 5.0 1.4X102 1.0X10-3 2.7X10-2 7.4X10-3 2.0X10-1 Ar-37 Argon (18) 4.0X101 1.1X103 4.0X101 1.1X103 3.7X103 9.9X104 Ar-39 4.0X101 1.1X103 2.0X101 5.4X102 1.3 3.4X101 Ar-41 3.0X10-1 8.1 3.0X10-1 8.1 1.5X106 4.2X107 As-72 Arsenic (33) 3.0X10-1 8.1 3.0X10-1 8.1 6.2X104 1.7X106 As-73 4.0X101 1.1X103 4.0X101 1.1X103 8.2X102 2.2X104 As-74 1.0 2.7X101 9.0X10-1 2.4X101 3.7X103 9.9X104 As-76 3.0X10-1 8.1 3.0X10-1 8.1 5.8X104 1.6X106
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
As-77 2.0X101 5.4X102 7.0X10-1 1.9X101 3.9X104 1.0X106 At-211 (a)
Astatine (85) 2.0X101 5.4X102 5.0X10-1 1.4X101 7.6X104 2.1X106 Au-193 Gold (79) 7.0 1.9X102 2.0 5.4X101 3.4X104 9.2X105 Au-194 1.0 2.7X101 1.0 2.7X101 1.5X104 4.1X105 Au-195 1.0X101 2.7X102 6.0 1.6X102 1.4X102 3.7X103 Au-198 1.0 2.7X101 6.0X10-1 1.6X101 9.0X103 2.4X105 Au-199 1.0X101 2.7X102 6.0X10-1 1.6X101 7.7X103 2.1X105 Ba-131 (a)
Barium (56) 2.0 5.4X101 2.0 5.4X101 3.1X103 8.4X104 Ba-133 3.0 8.1X101 3.0 8.1X101 9.4 2.6X102 Ba-133m 2.0X101 5.4X102 6.0X10-1 1.6X101 2.2X104 6.1X105 Ba-140 (a) 5.0X10-1 1.4X101 3.0X10-1 8.1 2.7X103 7.3X104 Be-7 Beryllium (4) 2.0X101 5.4X102 2.0X101 5.4X102 1.3X104 3.5X105 Be-10 4.0X101 1.1X103 6.0X10-1 1.6X101 8.3X10-4 2.2X10-2 Bi-205 Bismuth (83) 7.0X10-1 1.9X101 7.0X10-1 1.9X101 1.5X103 4.2X104 Bi-206 3.0X10-1 8.1 3.0X10-1 8.1 3.8X103 1.0X105 Bi-207 7.0X10-1 1.9X101 7.0X10-1 1.9X101 1.9 5.2X101 Bi-210 1.0 2.7X101 6.0X10-1 1.6X101 4.6X103 1.2X105 Bi-210m (a) 6.0X10-1 1.6X101 2.0X10-2 5.4X10-1 2.1X10-5 5.7X10-4 Bi-212 (a) 7.0X10-1 1.9X101 6.0X10-1 1.6X101 5.4X105 1.5X107 Bk-247 Berkelium (97) 8.0 2.2X102 8.0X10-4 2.2X10-2 3.8X10-2
1.0 Figure
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Bk-249 (a) 4.0X101 1.1X103 3.0X10-1 8.1 6.1X101 1.6X103 Br-76 Bromine (35) 4.0X10-1 1.1X101 4.0X10-1 1.1X101 9.4X104 2.5X106 Br-77 3.0 8.1X101 3.0 8.1X101 2.6X104 7.1X105 Br-82 4.0X10-1 1.1X101 4.0X10-1 1.1X101 4.0X104 1.1X106 C-11 Carbon (6) 1.0 2.7X101 6.0X10-1 1.6X101 3.1X107 8.4X108 C-14 4.0X101 1.1X103 3.0 8.1X101 1.6X10-1 4.5 Ca-41 Calcium (20)
Unlimited Unlimited Unlimited Unlimited 3.1X10-3 8.5X10-2 Ca-45 4.0X101 1.1X103 1.0 2.7X101 6.6X102 1.8X104 Ca-47 (a) 3.0 8.1X101 3.0X10-1 8.1 2.3X104 6.1X105 Cd-109 Cadmium (48) 3.0X101 8.1X102 2.0 5.4X101 9.6X101 2.6X103 Cd-113m 4.0X101 1.1X103 5.0X10-1 1.4X101 8.3 2.2X102 Cd-115 (a) 3.0 8.1X101 4.0X10-1 1.1X101 1.9X104 5.1X105 Cd-115m 5.0X10-1 1.4X101 5.0X10-1 1.4X101 9.4X102 2.5X104 Ce-139 Cerium (58) 7.0 1.9X102 2.0 5.4X101 2.5X102 6.8X103 Ce-141 2.0X101 5.4X102 6.0X10-1 1.6X101 1.1X103 2.8X104 Ce-143 9.0X10-1 2.4X101 6.0X10-1 1.6X101 2.5X104 6.6X105 Ce-144 (a) 2.0X10-1 5.4 2.0X10-1 5.4 1.2X102 3.2X103 Cf-248 Californium (98) 4.0X101 1.1X103 6.0X10-3 1.6X10-1 5.8X101 1.6X103 Cf-249 3.0 8.1X101 8.0X10-4 2.2X10-2 1.5X10-1 4.1 Cf-250 2.0X101 5.4X102 2.0X10-3 5.4X10-2 4.0 1.1X102
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Cf-251 7.0 1.9X102 7.0X10-4 1.9X10-2 5.9X10-2 1.6 Cf-252 1.0X10-2 2.7 3.0X10-3 8.1X10-2 2.0X101 5.4X102 Cf-253 (a) 4.0X101 1.1X103 4.0X10-2 1.1 1.1X103 2.9X104 Cf-254 1.0X10-3 2.7X10-2 1.0X10-3 2.7X10-2 3.1X102 8.5X103 Cl-36 Chlorine (17) 1.0X101 2.7X102 6.0X10-1 1.6X101 1.2X10-3 3.3X10-2 Cl-38 2.0X10-1 5.4 2.0X10-1 5.4 4.9X106 1.3X108 Cm-240 Curium (96) 4.0X101 1.1X103 2.0X10-2 5.4X10-1 7.5X102 2.0X104 Cm-241 2.0 5.4X101 1.0 2.7X101 6.1X102 1.7X104 Cm-242 4.0X101 1.1X103 1.0X10-2 2.7X10-1 1.2X102 3.3X103 Cm-243 9.0 2.4X102 1.0X10-3 2.7X10-2 1.9X10-3 5.2X101 Cm-244 2.0X101 5.4X102 2.0X10-3 5.4X10-2 3.0 8.1X101 Cm-245 9.0 2.4X102 9.0X10-4 2.4X10-2 6.4X10-3 1.7X10-1 Cm-246 9.0 2.4X102 9.0X10-4 2.4X10-2 1.1X10-2 3.1X10-1 Cm-247 (a) 3.0 8.1X101 1.0X10-3 2.7X10-2 3.4X10-6 9.3X10-5 Cm-248 2.0X10-2 5.4X10-1 3.0X10-4 8.1X10-3 1.6X10-4 4.2X10-3 Co-55 Cobalt (27) 5.0X10-1 1.4X101 5.0X10-1 1.4X101 1.1X105 3.1X106 Co-56 3.0X10-1 8.1 3.0X10-1 8.1 1.1X103 3.0X104 Co-57 1.0X101 2.7X102 1.0X101 2.7X102 3.1X102 8.4X103 Co-58 1.0 2.7X101 1.0 2.7X101 1.2X103 3.2X104 Co-58m 4.0X101 1.1X103 4.0X101 1.1X103 2.2X105 5.9X106
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Co-60 4.0X10-1 1.1X101 4.0X10-1 1.1X101 4.2X101 1.1X103 Cr-51 Chromium (24) 3.0X101 8.1X102 3.0X101 8.1X102 3.4X103 9.2X104 Cs-129 Cesium (55) 4.0 1.1X102 4.0 1.1X102 2.8X104 7.6X105 Cs-131 3.0X101 8.1X102 3.0X101 8.1X102 3.8X103 1.0X105 Cs-132 1.0 2.7X101 1.0 2.7X101 5.7X103 1.5X105 Cs-134 7.0X10-1 1.9X101 7.0X10-1 1.9X101 4.8X101 1.3X103 Cs-134m 4.0X101 1.1X103 6.0X10-1 1.6X101 3.0X105 8.0X106 Cs-135 4.0X101 1.1X103 1.0 2.7X101 4.3X10-5 1.2X10-3 Cs-136 5.0X10-1 1.4X101 5.0X10-1 1.4X101 2.7X103 7.3X104 Cs-137 (a) 2.0 5.4X101 6.0X10-1 1.6X101 3.2 8.7X101 Cu-64 Copper (29) 6.0 1.6X102 1.0 2.7X101 1.4X105 3.9X106 Cu-67 1.0X101 2.7X102 7.0X10-1 1.9X101 2.8X104 7.6X105 Dy-159 Dysprosium (66) 2.0X101 5.4X102 2.0X101 5.4X102 2.1X102 5.7X103 Dy-165 9.0X10-1 2.4X101 6.0X10-1 1.6X101 3.0X105 8.2X106 Dy-166 (a) 9.0X10-1 2.4X101 3.0X10-1 8.1 8.6X103 2.3X105 Er-169 Erbium (68) 4.0X101 1.1X103 1.0 2.7X101 3.1X103 8.3X104 Er-171 8.0X10-1 2.2X101 5.0X10-1 1.4X101 9.0X104 2.4X106 Eu-147 Europium (63) 2.0 5.4X101 2.0 5.4X101 1.4X103 3.7X104 Eu-148 5.0X10-1 1.4X101 5.0X10-1 1.4X101 6.0X102 1.6X104 Eu-149 2.0X101 5.4X102 2.0X101 5.4X102 3.5X102 9.4X103
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Eu-150 (short lived) 2.0 5.4X101 7.0X10-1 1.9X101 6.1X104 1.6X106 Eu-150 (long lived) 7.0X10-1 1.9X101 7.0X10-1 1.9X101 6.1X104 1.6X106 Eu-152 1.0 2.7X101 1.0 2.7X101 6.5 1.8X102 Eu-152m 8.0X10-1 2.2X101 8.0X10-1 2.2X101 8.2X104 2.2X106 Eu-154 9.0X10-1 2.4X101 6.0X10-1 1.6X101 9.8 2.6X102 Eu-155 2.0X101 5.4X102 3.0 8.1X101 1.8X101 4.9X102 Eu-156 7.0X10-1 1.9X101 7.0X10-1 1.9X101 2.0X103 5.5X104 F-18 Fluorine (9) 1.0 2.7X101 6.0X10-1 1.6X101 3.5X106 9.5X107 Fe-52 (a)
Iron (26) 3.0X10-1 8.1 3.0X10-1 8.1 2.7X105 7.3X106 Fe-55 4.0X101 1.1X103 4.0X101 1.1X103 8.8X101 2.4X103 Fe-59 9.0X10-1 2.4X101 9.0X10-1 2.4X101 1.8X103 5.0X104 Fe-60 (a) 4.0X101 1.1X103 2.0X10-1 5.4 7.4X10-4 2.0X10-2 Ga-67 Gallium (31) 7.0 1.9X102 3.0 8.1X101 2.2X104 6.0X105 Ga-68 5.0X10-1 1.4X101 5.0X10-1 1.4X101 1.5X106 4.1X107 Ga-72 4.0X10-1 1.1X101 4.0X10-1 1.1X101 1.1X105 3.1X106 Gd-146 (a)
Gadolinium (64) 5.0X10-1 1.4X101 5.0X10-1 1.4X101 6.9X102 1.9X104 Gd-148 2.0X101 5.4X102 2.0X10-3 5.4X10-2 1.2 3.2X101 Gd-153 1.0X101 2.7X102 9.0 2.4X102 1.3X102 3.5X103 Gd-159 3.0 8.1X101 6.0X10-1 1.6X101 3.9X104 1.1X106 Ge-68 (a)
Germanium (32) 5.0X10-1 1.4X101 5.0X10-1 1.4X101 2.6X102 7.1X103
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Ge-71 4.0X101 1.1X103 4.0X101 1.1X103 5.8X103 1.6X105 Ge-77 3.0X10-1 8.1 3.0X10-1 8.1 1.3X105 3.6X106 Hf-172 (a)
Hafnium (72) 6.0X10-1 1.6X101 6.0X10-1 1.6X101 4.1X101 1.1X103 Hf-175 3.0 8.1X101 3.0 8.1X101 3.9X102 1.1X104 Hf-181 2.0 5.4X101 5.0X10-1 1.4X101 6.3X102 1.7X104 Hf-182 Unlimited Unlimited Unlimited Unlimited 8.1X10-6 2.2X10-4 Hg-194 (a)
Mercury (80) 1.0 2.7X101 1.0 2.7X101 1.3X10-1 3.5 Hg-195m (a) 3.0 8.1X101 7.0X10-1 1.9X101 1.5X104 4.0X105 Hg-197 2.0X101 5.4X102 1.0X101 2.7X102 9.2X103 2.5X105 Hg-197m 1.0X101 2.7X102 4.0X10-1 1.1X101 2.5X104 6.7X105 Hg-203 5.0 1.4X102 1.0 2.7X101 5.1X102 1.4X104 Ho-166 Holmium (67) 4.0X10-1 1.1X101 4.0X10-1 1.1X101 2.6X104 7.0X105 Ho-166m 6.0X10-1 1.6X101 5.0X10-1 1.4X101 6.6X10-2 1.8 I-123 Iodine (53) 6.0 1.6X102 3.0 8.1X101 7.1X104 1.9X106 I-124 1.0 2.7X101 1.0 2.7X101 9.3X103 2.5X105 I-125 2.0X101 5.4X102 3.0 8.1X101 6.4X102 1.7X104 I-126 2.0 5.4X101 1.0 2.7X101 2.9X103 8.0X104 I-129 Unlimited Unlimited Unlimited Unlimited 6.5X10-6 1.8X10-4 I-131 3.0 8.1X101 7.0X10-1 1.9X101 4.6X103 1.2X105 I-132 4.0X10-1 1.1X101 4.0X10-1 1.1X101 3.8X105 1.0X107
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
I-133 7.0X10-1 1.9X101 6.0X10-1 1.6X101 4.2X104 1.1X106 I-134 3.0X10-1 8.1 3.0X10-1 8.1 9.9X105 2.7X107 I-135 (a) 6.0X10-1 1.6X101 6.0X10-1 1.6X101 1.3X105 3.5X106 In-111 Indium (49) 3.0 8.1X101 3.0 8.1X101 1.5X104 4.2X105 In-113m 4.0 1.1X102 2.0 5.4X101 6.2X105 1.7X107 In-114m (a) 1.0X101 2.7X102 5.0X10-1 1.4X101 8.6X102 2.3X104 In-115m 7.0 1.9X102 1.0 2.7X101 2.2X105 6.1X106 Ir-189 (a)
Iridium (77) 1.0X101 2.7X102 1.0X101 2.7X102 1.9X103 5.2X104 Ir-190 7.0X10-1 1.9X101 7.0X10-1 1.9X101 2.3X103 6.2X104 Ir-192 (c) 1.0 (c) 2.7x101 6.0X10-1 1.6X101 3.4X102 9.2X103 Ir-194 3.0X10-1 8.1 3.0X10-1 8.1 3.1X104 8.4X105 K-40 Potassium (19) 9.0X10-1 2.4X101 9.0X10-1 2.4X101 2.4X10-7 6.4X10-6 K-42 2.0X10-1 5.4 2.0X10-1 5.4 2.2X105 6.0X106 K-43 7.0X10-1 1.9X101 6.0X10-1 1.6X101 1.2X105 3.3X106 Kr-79 Krypton (36) 4.0 1.1X102 2.0 5.4X101 4.2X104 1.1X106 Kr-81 4.0X101 1.1X103 4.0X101 1.1X103 7.8X10-4 2.1X10-2 Kr-85 1.0X101 2.7X102 1.0X101 2.7X102 1.5X101 3.9X102 Kr-85m 8.0 2.2X102 3.0 8.1X101 3.0X105 8.2X106 Kr-87 2.0X10-1 5.4 2.0X10-1 5.4 1.0X106 2.8X107 La-137 Lanthanum (57) 3.0X101 8.1X102 6.0 1.6X102 1.6X10-3 4.4X10-2
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
La-140 4.0X10-1 1.1X101 4.0X10-1 1.1X101 2.1X104 5.6X105 Lu-172 Lutetium (71) 6.0X10-1 1.6X101 6.0X10-1 1.6X101 4.2X103 1.1X105 Lu-173 8.0 2.2X102 8.0 2.2X102 5.6X101 1.5X103 Lu-174 9.0 2.4X102 9.0 2.4X102 2.3X101 6.2X102 Lu-174m 2.0X101 5.4X102 1.0X101 2.7X102 2.0X102 5.3X103 Lu-177 3.0X101 8.1X102 7.0X10-1 1.9X101 4.1X103 1.1X105 Mg-28 (a)
Magnesium (12) 3.0X10-1 8.1 3.0X10-1 8.1 2.0X105 5.4X106 Mn-52 Manganese (25) 3.0X10-1 8.1 3.0X10-1 8.1 1.6X104 4.4X105 Mn-53 Unlimited Unlimited Unlimited Unlimited 6.8X10-5 1.8X10-3 Mn-54 1.0 2.7X101 1.0 2.7X101 2.9X102 7.7X103 Mn-56 3.0X10-1 8.1 3.0X10-1 8.1 8.0X105 2.2X107 Mo-93 Molybdenum (42) 4.0X101 1.1X103 2.0X101 5.4X102 4.1X10-2 1.1 Mo-99 (a) (h) 1.0 2.7X101 6.0X10-1 1.6X101 1.8X104 4.8X105 N-13 Nitrogen (7) 9.0X10-1 2.4X101 6.0X10-1 1.6X101 5.4X107 1.5X109 Na-22 Sodium (11) 5.0X10-1 1.4X101 5.0X10-1 1.4X101 2.3X102 6.3X103 Na-24 2.0X10-1 5.4 2.0X10-1 5.4 3.2X105 8.7X106 Nb-93m Niobium (41) 4.0X101 1.1X103 3.0X101 8.1X102 8.8 2.4X102 Nb-94 7.0X10-1 1.9X101 7.0X10-1 1.9X101 6.9X10-3 1.9X10-1 Nb-95 1.0 2.7X101 1.0 2.7X101 1.5X103 3.9X104 Nb-97 9.0X10-1 2.4X101 6.0X10-1 1.6X101 9.9X105 2.7X107
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Nd-147 Neodymium (60) 6.0 1.6X102 6.0X10-1 1.6X101 3.0X103 8.1X104 Nd-149 6.0X10-1 1.6X101 5.0X10-1 1.4X101 4.5X105 1.2X107 Ni-59 Nickel (28)
Unlimited Unlimited Unlimited Unlimited 3.0X10-3 8.0X10-2 Ni-63 4.0X101 1.1X103 3.0X101 8.1X102 2.1 5.7X101 Ni-65 4.0X10-1 1.1X101 4.0X10-1 1.1X101 7.1X105 1.9X107 Np-235 Neptunium (93) 4.0X101 1.1X103 4.0X101 1.1X103 5.2X101 1.4X103 Np-236 (short-lived) 2.0X101 5.4X102 2.0 5.4X101 4.7X10-4 1.3X10-2 Np-236 (long-lived) 9.0X100 2.4X102 2.0X10-2 5.4X10-1 4.7X10-4 1.3X10-2 Np-237 2.0X101 5.4X102 2.0X10-3 5.4X10-2 2.6X10-5 7.1X10-4 Np-239 7.0 1.9X102 4.0X10-1 1.1X101 8.6X103 2.3X105 Os-185 Osmium (76) 1.0 2.7X101 1.0 2.7X101 2.8X102 7.5X103 Os-191 1.0X101 2.7X102 2.0 5.4X101 1.6X103 4.4X104 Os-191m 4.0X101 1.1X103 3.0X101 8.1X102 4.6X104 1.3X106 Os-193 2.0 5.4X101 6.0X10-1 1.6X101 2.0X104 5.3X105 Os-194 (a) 3.0X10-1 8.1 3.0X10-1 8.1 1.1X101 3.1X102 P-32 Phosphorus (15) 5.0X10-1 1.4X101 5.0X10-1 1.4X101 1.1X104 2.9X105 P-33 4.0X101 1.1X103 1.0 2.7X101 5.8X103 1.6X105 Pa-230 (a)
Protactinium (91) 2.0 5.4X101 7.0X10-2 1.9 1.2X103 3.3X104 Pa-231 4.0 1.1X102 4.0X10-4 1.1X10-2 1.7X10-3 4.7X10-2 Pa-233 5.0 1.4X102 7.0X10-1 1.9X101 7.7X102 2.1X104
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Pb-201 Lead (82) 1.0 2.7X101 1.0 2.7X101 6.2X104 1.7X106 Pb-202 4.0X101 1.1X103 2.0X101 5.4X102 1.2X10-4 3.4X10-3 Pb-203 4.0 1.1X102 3.0 8.1X101 1.1X104 3.0X105 Pb-205 Unlimited Unlimited Unlimited Unlimited 4.5X10-6 1.2X10-4 Pb-210 (a) 1.0 2.7X101 5.0X10-2 1.4 2.8 7.6X101 Pb-212 (a) 7.0X10-1 1.9X101 2.0X10-1 5.4 5.1X104 1.4X106 Pd-103 (a)
Palladium (46) 4.0X101 1.1X103 4.0X101 1.1X103 2.8X103 7.5X104 Pd-107 Unlimited Unlimited Unlimited Unlimited 1.9X10-5 5.1X10-4 Pd-109 2.0 5.4X101 5.0X10-1 1.4X101 7.9X104 2.1X106 Pm-143 Promethium (61) 3.0 8.1X101 3.0 8.1X101 1.3X102 3.4X103 Pm-144 7.0X10-1 1.9X101 7.0X10-1 1.9X101 9.2X101 2.5X103 Pm-145 3.0X101 8.1X102 1.0X101 2.7X102 5.2 1.4X102 Pm-147 4.0X101 1.1X103 2.0 5.4X101 3.4X101 9.3X102 Pm-148m (a) 8.0X10-1 2.2X101 7.0X10-1 1.9X101 7.9X102 2.1X104 Pm-149 2.0 5.4X101 6.0X10-1 1.6X101 1.5X104 4.0X105 Pm-151 2.0 5.4X101 6.0X10-1 1.6X101 2.7X104 7.3X105 Po-210 Polonium (84) 4.0X101 1.1X103 2.0X10-2 5.4X10-1 1.7X102 4.5X103 Pr-142 Praseodymium (59) 4.0X10-1 1.1X101 4.0X10-1 1.1X101 4.3X104 1.2X106 Pr-143 3.0 8.1X101 6.0X10-1 1.6X101 2.5X103 6.7X104 Pt-188 (a)
Platinum (78) 1.0 2.7X101 8.0X10-1 2.2X101 2.5X103 6.8X104
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Pt-191 4.0 1.1X102 3.0 8.1X101 8.7X103 2.4X105 Pt-193 4.0X101 1.1X103 4.0X101 1.1X103 1.4 3.7X101 Pt-193m 4.0X101 1.1X103 5.0X10-1 1.4X101 5.8X103 1.6X105 Pt-195m 1.0X101 2.7X102 5.0X10-1 1.4X101 6.2X103 1.7X105 Pt-197 2.0X101 5.4X102 6.0X10-1 1.6X101 3.2X104 8.7X105 Pt-197m 1.0X101 2.7X102 6.0X10-1 1.6X101 3.7X105 1.0X107 Pu-236 Plutonium (94) 3.0X101 8.1X102 3.0X10-3 8.1X10-2 2.0X101 5.3X102 Pu-237 2.0X101 5.4X102 2.0X101 5.4X102 4.5X102 1.2X104 Pu-238 1.0X101 2.7X102 1.0X10-3 2.7X10-2 6.3X10-1 1.7X101 Pu-239 1.0X101 2.7X102 1.0X10-3 2.7X10-2 2.3X10-3 6.2X10-2 Pu-240 1.0X101 2.7X102 1.0X10-3 2.7X10-2 8.4X10-3 2.3X10-1 Pu-241 (a) 4.0X101 1.1X103 6.0X10-2 1.6 3.8 1.0X102 Pu-242 1.0X101 2.7X102 1.0X10-3 2.7X10-2 1.5X10-4 3.9X10-3 Pu-244 (a) 4.0X10-1 1.1X101 1.0X10-3 2.7X10-2 6.7X10-7 1.8X10-5 Ra-223 (a)
Radium (88) 4.0X10-1 1.1X101 7.0X10-3 1.9X10-1 1.9X103 5.1X104 Ra-224 (a) 4.0X10-1 1.1X101 2.0X10-2 5.4X10-1 5.9X103 1.6X105 Ra-225 (a) 2.0X10-1 5.4 4.0X10-3 1.1X10-1 1.5X103 3.9X104 Ra-226 (a) 2.0X10-1 5.4 3.0X10-3 8.1X10-2 3.7X10-2 1.0 Ra-228 (a) 6.0X10-1 1.6X101 2.0X10-2 5.4X10-1 1.0X101 2.7X102 Rb-81 Rubidium (37) 2.0 5.4X101 8.0X10-1 2.2X101 3.1X105 8.4X106
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Rb-83 (a) 2.0 5.4X101 2.0 5.4X101 6.8X102 1.8X104 Rb-84 1.0 2.7X101 1.0 2.7X101 1.8X103 4.7X104 Rb-86 5.0X10-1 1.4X101 5.0X10-1 1.4X101 3.0X103 8.1X104 Rb-87 Unlimited Unlimited Unlimited Unlimited 3.2X10-9 8.6X10-8 Rb(nat)
Unlimited Unlimited Unlimited Unlimited 6.7X106 1.8X108 Re-184 Rhenium (75) 1.0 2.7X101 1.0 2.7X101 6.9X102 1.9X104 Re-184m 3.0 8.1X101 1.0 2.7X101 1.6X102 4.3X103 Re-186 2.0 5.4X101 6.0X10-1 1.6X101 6.9X103 1.9X105 Re-187 Unlimited Unlimited Unlimited Unlimited 1.4X10-9 3.8X10-8 Re-188 4.0X10-1 1.1X101 4.0X10-1 1.1X101 3.6X104 9.8X105 Re-189 (a) 3.0 8.1X101 6.0X10-1 1.6X101 2.5X104 6.8X105 Re(nat)
Unlimited Unlimited Unlimited Unlimited 0.0 2.4X10-8 Rh-99 Rhodium (45) 2.0 5.4X101 2.0 5.4X101 3.0X103 8.2X104 Rh-101 4.0 1.1X102 3.0 8.1X101 4.1X101 1.1X103 Rh-102 5.0X10-1 1.4X101 5.0X10-1 1.4X101 4.5X101 1.2X103 Rh-102m 2.0 5.4X101 2.0 5.4X101 2.3X102 6.2X103 Rh-103m 4.0X101 1.1X103 4.0X101 1.1X103 1.2X106 3.3X107 Rh-105 1.0X101 2.7X102 8.0X10-1 2.2X101 3.1X104 8.4X105 Rn-222 (a)
Radon (86) 3.0X10-1 8.1 4.0X10-3 1.1X10-1 5.7X103 1.5X105 Ru-97 Ruthenium (44) 5.0 1.4X102 5.0 1.4X102 1.7X104 4.6X105
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Ru-103 (a) 2.0 5.4X101 2.0 5.4X101 1.2X103 3.2X104 Ru-105 1.0 2.7X101 6.0X10-1 1.6X101 2.5X105 6.7X106 Ru-106 (a) 2.0X10-1 5.4 2.0X10-1 5.4 1.2X102 3.3X103 S-35 Sulfur (16) 4.0X101 1.1X103 3.0 8.1X101 1.6X103 4.3X104 Sb-122 Antimony (51) 4.0X10-1 1.1X101 4.0X10-1 1.1X101 1.5X104 4.0X105 Sb-124 6.0X10-1 1.6X101 6.0X10-1 1.6X101 6.5X102 1.7X104 Sb-125 2.0 5.4X101 1.0 2.7X101 3.9X101 1.0X103 Sb-126 4.0X10-1 1.1X101 4.0X10-1 1.1X101 3.1X103 8.4X104 Sc-44 Scandium (21) 5.0X10-1 1.4X101 5.0X10-1 1.4X101 6.7X105 1.8X107 Sc-46 5.0X10-1 1.4X101 5.0X10-1 1.4X101 1.3X103 3.4X104 Sc-47 1.0X101 2.7X102 7.0X10-1 1.9X101 3.1X104 8.3X105 Sc-48 3.0X10-1 8.1 3.0X10-1 8.1 5.5X104 1.5X106 Se-75 Selenium (34) 3.0 8.1X101 3.0 8.1X101 5.4X102 1.5X104 Se-79 4.0X101 1.1X103 2.0 5.4X101 2.6X10-3 7.0X10-2 Si-31 Silicon (14) 6.0X10-1 1.6X101 6.0X10-1 1.6X101 1.4X106 3.9X107 Si-32 4.0X101 1.1X103 5.0X10-1 1.4X101 3.9 1.1X102 Sm-145 Samarium (62) 1.0X101 2.7X102 1.0X101 2.7X102 9.8X101 2.6X103 Sm-147 Unlimited Unlimited Unlimited Unlimited 8.5X10-1 2.3X10-8 Sm-151 4.0X101 1.1X103 1.0X101 2.7X102 9.7X10-1 2.6X101 Sm-153 9.0 2.4X102 6.0X10-1 1.6X101 1.6X104 4.4X105
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Sn-113 (a)
Tin (50) 4.0 1.1X102 2.0 5.4X101 3.7X102 1.0X104 Sn-117m 7.0 1.9X102 4.0X10-1 1.1X101 3.0X103 8.2X104 Sn-119m 4.0X101 1.1X103 3.0X101 8.1X102 1.4X102 3.7X103 Sn-121m (a) 4.0X101 1.1X103 9.0X10-1 2.4X101 2.0 5.4X101 Sn-123 8.0X10-1 2.2X101 6.0X10-1 1.6X101 3.0X102 8.2X103 Sn-125 4.0X10-1 1.1X101 4.0X10-1 1.1X101 4.0X103 1.1X105 Sn-126 (a) 6.0X10-1 1.6X101 4.0X10-1 1.1X101 1.0X10-3 2.8X10-2 Sr-82 (a)
Strontium (38) 2.0X10-1 5.4 2.0X10-1 5.4 2.3X103 6.2X104 Sr-85 2.0 5.4X101 2.0 5.4X101 8.8X102 2.4X104 Sr-85m 5.0 1.4X102 5.0 1.4X102 1.2X106 3.3X107 Sr-87m 3.0 8.1X101 3.0 8.1X101 4.8X105 1.3X107 Sr-89 6.0X10-1 1.6X101 6.0X10-1 1.6X101 1.1X103 2.9X104 Sr-90 (a) 3.0X10-1 8.1 3.0X10-1 8.1 5.1 1.4X102 Sr-91 (a) 3.0X10-1 8.1 3.0X10-1 8.1 1.3X105 3.6X106 Sr-92 (a) 1.0 2.7X101 3.0X10-1 8.1 4.7X105 1.3X107 T(H-3)
Tritium (1) 4.0X101 1.1X103 4.0X101 1.1X103 3.6X102 9.7X103 Ta-178 (long-lived)
Tantalum (73) 1.0 2.7X101 8.0X10-1 2.2X101 4.2X106 1.1X108 Ta-179 3.0X101 8.1X102 3.0X101 8.1X102 4.1X101 1.1X103 Ta-182 9.0X10-1 2.4X101 5.0X10-1 1.4X101 2.3X102 6.2X103 Tb-157 Terbium (65) 4.0X101 1.1X103 4.0X101 1.1X103 5.6X10-1 1.5X101
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Tb-158 1.0 2.7X101 1.0 2.7X101 5.6X10-1 1.5X101 Tb-160 1.0 2.7X101 6.0X10-1 1.6X101 4.2X102 1.1X104 Tc-95m (a)
Technetium (43) 2.0 5.4X101 2.0 5.4X101 8.3X102 2.2X104 Tc-96 4.0X10-1 1.1X101 4.0X10-1 1.1X101 1.2X104 3.2X105 Tc-96m (a) 4.0X10-1 1.1X101 4.0X10-1 1.1X101 1.4X106 3.8X107 Tc-97 Unlimited Unlimited Unlimited Unlimited 5.2X10-5 1.4X10-3 Tc-97m 4.0X101 1.1X103 1.0 2.7X101 5.6X102 1.5X104 Tc-98 8.0X10-1 2.2X101 7.0X10-1 1.9X101 3.2X10-5 8.7X10-4 Tc-99 4.0X101 1.1X103 9.0X10-1 2.4X101 6.3X10-4 1.7X10-2 Tc-99m 1.0X101 2.7X102 4.0 1.1X102 1.9X105 5.3X106 Te-121 Tellurium (52) 2.0 5.4X101 2.0 5.4X101 2.4X103 6.4X104 Te-121m 5.0 1.4X102 3.0 8.1X101 2.6X102 7.0X103 Te-123m 8.0 2.2X102 1.0 2.7X101 3.3X102 8.9X103 Te-125m 2.0X101 5.4X102 9.0X10-1 2.4X101 6.7X102 1.8X104 Te-127 2.0X101 5.4X102 7.0X10-1 1.9X101 9.8X104 2.6X106 Te-127m (a) 2.0X101 5.4X102 5.0X10-1 1.4X101 3.5X102 9.4X103 Te-129 7.0X10-1 1.9X101 6.0X10-1 1.6X101 7.7X105 2.1X107 Te-129m (a) 8.0X10-1 2.2X101 4.0X10-1 1.1X101 1.1X103 3.0X104 Te-131m (a) 7.0X10-1 1.9X101 5.0X10-1 1.4X101 3.0X104 8.0X105 Te-132 (a) 5.0X10-1 1.4X101 4.0X10-1 1.1X101 1.1X104 3.0X105
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Th-227 Thorium (90) 1.0X101 2.7X102 5.0X10-3 1.4X10-1 1.1X103 3.1X104 Th-228 (a) 5.0X10-1 1.4X101 1.0X10-3 2.7X10-2 3.0X101 8.2X102 Th-229 5.0 1.4X102 5.0X10-4 1.4X10-2 7.9X10-3 2.1X10-1 Th-230 1.0X101 2.7X102 1.0X10-3 2.7X10-2 7.6X10-4 2.1X10-2 Th-231 4.0X101 1.1X103 2.0X10-2 5.4X10-1 2.0X104 5.3X105 Th-232 Unlimited Unlimited Unlimited Unlimited 4.0X10-9 1.1X10-7 Th-234 (a) 3.0X10-1 8.1 3.0X10-1 8.1 8.6X102 2.3X104 Th(nat)
Unlimited Unlimited Unlimited Unlimited 8.1X10-9 2.2X10-7 Ti-44 (a)
Titanium (22) 5.0X10-1 1.4X101 4.0X10-1 1.1X101 6.4 1.7X102 Tl-200 Thallium (81) 9.0X10-1 2.4X101 9.0X10-1 2.4X101 2.2X104 6.0X105 Tl-201 1.0X101 2.7X102 4.0 1.1X102 7.9X103 2.1X105 Tl-202 2.0 5.4X101 2.0 5.4X101 2.0X103 5.3X104 Tl-204 1.0X101 2.7X102 7.0X10-1 1.9X101 1.7X101 4.6X102 Tm-167 Thulium (69) 7.0 1.9X102 8.0X10-1 2.2X101 3.1X103 8.5X104 Tm-170 3.0 8.1X101 6.0X10-1 1.6X101 2.2X102 6.0X103 Tm-171 4.0X101 1.1X103 4.0X101 1.1X103 4.0X101 1.1X103 U-230 (fast lung absorption) (a)(d)
Uranium (92) 4.0X101 1.1X103 1.0X10-1 2.7 1.0X103 2.7X104 U-230 (medium lung absorption) (a)(e) 4.0X101 1.1X103 4.0X10-3 1.1X10-1 1.0X103 2.7X104 U-230 (slow lung 3.0X101 8.1X102 3.0X10-3 8.1X10-2 1.0X103 2.7X104
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g) absorption) (a)(f)
U-232 (fast lung absorption) (d) 4.0X101 1.1X103 1.0X10-2 2.7X10-1 8.3X10-1 2.2X101 U-232 (medium lung absorption) (e) 4.0X101 1.1X103 7.0X10-3 1.9X10-1 8.3X10-1 2.2X101 U-232 (slow lung absorption) (f) 1.0X101 2.7X102 1.0X10-3 2.7X10-2 8.3X10-1 2.2X101 U-233 (fast lung absorption) (d) 4.0X101 1.1X103 9.0X10-2 2.4 3.6X10-4 9.7X10-3 U-233 (medium lung absorption) (e) 4.0X101 1.1X103 2.0X10-2 5.4X10-1 3.6X10-4 9.7X10-3 U-233 (slow lung absorption) (f) 4.0X101 1.1X103 6.0X10-3 1.6X10-1 3.6X10-4 9.7X10-3 U-234 (fast lung absorption) (d) 4.0X101 1.1X103 9.0X10-2 2.4 2.3X10-4 6.2X10-3 U-234 (medium lung absorption) (e) 4.0X101 1.1X103 2.0X10-2 5.4X10-1 2.3X10-4 6.2X10-3 U-234 (slow lung absorption) (f) 4.0X101 1.1X103 6.0X10-3 1.6X10-1 2.3X10-4 6.2X10-3 U-235 (all lung absorption types)
(a),(d),(e),(f)
Unlimited Unlimited Unlimited Unlimited 8.0X10-8 2.2X10-6 U-236 (fast lung absorption) (d)
Unlimited Unlimited Unlimited Unlimited 2.4X10-6 6.5X10-5
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
U-236 (medium lung absorption) (e) 4.0X101 1.1X103 2.0X10-2 5.4X10-1 2.4X10-6 6.5X10-5 U-236 (slow lung absorption) (f) 4.0X101 1.1X103 6.0X10-3 1.6X10-1 2.4X10-6 6.5X10-5 U-238 (all lung absorption types)
(d),(e),(f)
Unlimited Unlimited Unlimited Unlimited 1.2X10-8 3.4X10-7 U (nat)
Unlimited Unlimited Unlimited Unlimited 2.6X10-8 7.1X10-7 U (enriched to 20%
or less) (g)
Unlimited Unlimited Unlimited Unlimited See Table 257-6 See Table 257-6 U (dep)
Unlimited Unlimited Unlimited Unlimited See Table 257-6 See Table 257-5 V-48 Vanadium (23) 4.0X10-1 1.1X101 4.0X10-1 1.1X101 6.3X103 1.7X105 V-49 4.0X101 1.1X103 4.0X101 1.1X103 3.0X102 8.1X103 W-178 (a)
Tungsten (74) 9.0 2.4X102 5.0 1.4X102 1.3X103 3.4X104 W-181 3.0X101 8.1X102 3.0X101 8.1X102 2.2X102 6.0X103 W-185 4.0X101 1.1X103 8.0X10-1 2.2X101 3.5X102 9.4X103 W-187 2.0 5.4X101 6.0X10-1 1.6X101 2.6X104 7.0X105 W-188 (a) 4.0X10-1 1.1X101 3.0X10-1 8.1 3.7X102 1.0X104 Xe-122 (a)
Xenon (54) 4.0X10-1 1.1X101 4.0X10-1 1.1X101 4.8X104 1.3X106 Xe-123 2.0 5.4X101 7.0X10-1 1.9X101 4.4X105 1.2X107 Xe-127 4.0 1.1X102 2.0 5.4X101 1.0X103 2.8X104 Xe-131m 4.0X101 1.1X103 4.0X101 1.1X103 3.1X103 8.4X104
Figure: 25 TAC §289.257(ee)(6)
Symbol of Radionuclide Element and atomic number A1 (TBq) A1(Ci)b A2 (TBq) A2(Ci)b Specific activity (TBq/g)
(Ci/g)
Xe-133 2.0X101 5.4X102 1.0X101 2.7X102 6.9X103 1.9X105 Xe-135 3.0 8.1X101 2.0 5.4X101 9.5X104 2.6X106 Y-87 (a)
Yttrium (39) 1.0 2.7X101 1.0 2.7X101 1.7X104 4.5X105 Y-88 4.0X10-1 1.1X101 4.0X10-1 1.1X101 5.2X102 1.4X104 Y-90 3.0X10-1 8.1 3.0X10-1 8.1 2.0X104 5.4X105 Y-91 6.0X10-1 1.6X101 6.0X10-1 1.6X101 9.1X102 2.5X104 Y-91m 2.0 5.4X101 2.0 5.4X101 1.5X106 4.2X107 Y-92 2.0X10-1 5.4 2.0X10-1 5.4 3.6X105 9.6X106 Y-93 3.0X10-1 8.1 3.0X10-1 8.1 1.2X105 3.3X106 Yb-169 Ytterbium (70) 4.0 1.1X102 1.0 2.7X101 8.9X102 2.4X104 Yb-175 3.0X101 8.1X102 9.0X10-1 2.4X101 6.6X103 1.8X105 Zn-65 Zinc (30) 2.0 5.4X101 2.0 5.4X101 3.0X102 8.2X103 Zn-69 3.0 8.1X101 6.0X10-1 1.6X101 1.8X106 4.9X107 Zn-69m (a) 3.0 8.1X101 6.0X10-1 1.6X101 1.2X105 3.3X106 Zr-88 Zirconium (40) 3.0 8.1X101 3.0 8.1X101 6.6X102 1.8X104 Zr-93 Unlimited Unlimited Unlimited Unlimited 9.3X10-5 2.5X10-3 Zr-95 (a) 2.0 5.4X101 8.0X10-1 2.2X101 7.9X102 2.1X104 Zr-97 (a) 4.0X10-1 1.1X101 4.0X10-1 1.1X101 7.1X104 1.9X106 a A1 and/or A2 values include contributions from daughter nuclides with half-lives less than 10 days, as listed in the following:
Figure: 25 TAC §289.257(ee)(6)
Mg-28 Al-28 Ca-47 Sc-47 Ti-44 Sc-44 Fe-52 Mn-52m Fe-60 Co-60m Zn-69m Zn-69 Ge-68 Ga-68 Rb-83 Kr-83m Sr-82 Rb-82 Sr-90 Y-90 Sr-91 Y-91m Sr-92 Y-92 Y-87 Sr-87m Zr-95 Nb-95m Zr-97 Nb-97m, Nb-97 Mo-99 Tc-99m Tc-95m Tc-95 Tc-96m Tc-96 Ru-103 Rh-103m Ru-106 Rh-106 Pd-103 Rh-103m Ag-108m Ag-108 Ag-110m Ag-110 Cd-115 In-115m In-114m In-114 Sn-113 In-113m
Figure: 25 TAC §289.257(ee)(6)
Sn-121m Sn-121 Sn-126 Sb-126m Te-127m Te-127 Te-129m Te-129 Te-131m Te-131 Te-132 I-132 I-135 Xe-135m Xe-122 I-122 Cs-137 Ba-137m Ba-131 Cs-131 Ba-140 La-140 Ce-144 Pr-144m, Pr-144 Pm-148m Pm-148 Gd-146 Eu-146 Dy-166 Ho-166 Hf-172 Lu-172 W-178 Ta-178 W-188 Re-188 Re-189 Os-189m Os-194 Ir-194 Ir-189 Os-189m Pt-188 Ir-188 Hg-194 Au-194 Hg-195m Hg-195 Pb-210 Bi-210 Pb-212 Bi-212, Tl-208, Po-212
Figure: 25 TAC §289.257(ee)(6)
Bi-210m Tl-206 Bi-212 Tl-208, Po-212 At-211 Po-211 Rn-222 Po-218, Pb-214, At-218, Bi-214, Po-214 Ra-223 Rn-219, Po-215, Pb-211, Bi-211, Po-211, Tl-207 Ra-224 Rn-220, Po-216, Pb-212, Bi-212, Tl-208, Po-212 Ra-225 Ac-225, Fr-221, At-217, Bi-213, Tl-209, Po-213, Pb-209 Ra-226 Rn-222, Po-218, Pb-214, At-218, Bi-214, Po-214 Ra-228 Ac-228 Ac-225 Fr-221, At-217, Bi-213, Tl-209, Po-213, Pb-209 Ac-227 Fr-223 Th-228 Ra-224, Rn-220, Po-216, Pb-212, Bi-212, Tl-208, Po-212 Th-234 Pa-234m, Pa-234 Pa-230 Ac-226, Th-226, Fr-222, Ra-222, Rn-218, Po-214 U-230 Th-226, Ra-222, Rn-218, Po-214 U-235 Th-231 Pu-241 U-237 Pu-244 U-240, Np-240m Am-242m Am-242, Np-238 Am-243 Np-239 Cm-247 Pu-243 Bk-249 Am-245 Cf-253 Cm-249 b The values of A1 and A2 in Curies (Ci) are approximate and for information only; the regulatory standard units are Terabecquerels (TBq), (see subsection (ee)(1) of this section - Determination of A1 and A2).
Figure: 25 TAC §289.257(ee)(6) c The activity of Ir-192 in special form may be determined from a measurement of the rate of decay or a measurement of the radiation level at a prescribed distance from the source.
d These values apply only to compounds of uranium that take the chemical form of UF6, UO2F2 and UO2(NO3)2 in both normal and accident conditions of transport.
e These values apply only to compounds of uranium that take the chemical form of UO3, UF4, UCl4 and hexavalent compounds in both normal and accident conditions of transport.
f These values apply to all compounds of uranium other than those specified in notes (d) and (e) of this table.
g These values apply to unirradiated uranium only.
- h. A2 = 0.74 TBq (20 Ci) for Mo-99 for domestic use.
Figure: 25 TAC §289.257(ee)(7)
Table 257 Exempt Material Activity Concentrations and Exempt Consignment Activity Limits for Radionuclides Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Ac-225 Actinium (89) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Ac-227 1.0X10-1 2.7X10-12 1.0X103 2.7X10-8 Ac-228 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Ag-105 Silver (47) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Ag-108m (b) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Ag-110m 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Ag-111 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Al-26 Aluminum (13) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Am-241 Americium (95) 1.0 2.7X10-11 1.0X104 2.7X10-7 Am-242m (b) 1.0 2.7X10-11 1.0X104 2.7X10-7 Am-243 (b) 1.0 2.7X10-11 1.0X103 2.7X10-8 Ar-37 Argon (18) 1.0X106 2.7X10-5 1.0X108 2.7X10-3 Ar-39 1.0X107 2.7X10-4 1.0X104 2.7X10-7 Ar-41 1.0X102 2.7X10-9 1.0X109 2.7X10-2 As-72 Arsenic (33) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 As-73 1.0X103 2.7X10-8 1.0X107 2.7X10-4
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
As-74 1.0X101 2.7X10-10 1.0X106 2.7X10-5 As-76 1.0X102 2.7X10-9 1.0X105 2.7X10-6 As-77 1.0X103 2.7X10-8 1.0X106 2.7X10-5 At-211 Astatine (85) 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Au-193 Gold (79) 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Au-194 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Au-195 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Au-198 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Au-199 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Ba-131 Barium (56) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Ba-133 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Ba-133m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Ba-140 (b) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Be-7 Beryllium (4) 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Be-10 1.0X104 2.7X10-7 1.0X106 2.7X10-5 Bi-205 Bismuth (83) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Bi-206 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Bi-207 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Bi-210 1.0X103 2.7X10-8 1.0X106 2.7X10-5
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Bi-210m 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Bi-212 (b) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Bk-247 Berkelium (97) 1.0 2.7X10-11 1.0X104 2.7X10-7 Bk-249 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Br-76 Bromine (35) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Br-77 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Br-82 1.0X101 2.7X10-10 1.0X106 2.7X10-5 C-11 Carbon (6) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 C-14 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Ca-41 Calcium (20) 1.0X105 2.7X10-6 1.0X107 2.7X10-4 Ca-45 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Ca-47 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Cd-109 Cadmium (48) 1.0X104 2.7X10-7 1.0X106 2.7X10-5 Cd-113m 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Cd-115 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Cd-115m 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Ce-139 Cerium (58) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Ce-141 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Ce-143 1.0X102 2.7X10-9 1.0X106 2.7X10-5
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Ce-144 (b) 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Cf-248 Californium (98) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Cf-249 1.0 2.7X10-11 1.0X103 2.7X10-8 Cf-250 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Cf-251 1.0 2.7X10-11 1.0X103 2.7X10-8 Cf-252 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Cf-253 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Cf-254 1.0 2.7X10-11 1.0X103 2.7X10-8 Cl-36 Chlorine (17) 1.0X104 2.7X10-7 1.0X106 2.7X10-5 Cl-38 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Cm-240 Curium (96) 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Cm-241 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Cm-242 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Cm-243 1.0 2.7X10-11 1.0X104 2.7X10-7 Cm-244 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Cm-245 1.0 2.7X10-11 1.0X103 2.7X10-8 Cm-246 1.0 2.7X10-11 1.0X103 2.7X10-8 Cm-247 1.0 2.7X10-11 1.0X104 2.7X10-7 Cm-248 1.0 2.7X10-11 1.0X103 2.7X10-8
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Co-55 Cobalt (27) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Co-56 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Co-57 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Co-58 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Co-58m 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Co-60 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Cr-51 Chromium (24) 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Cs-129 Cesium (55) 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Cs-131 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Cs-132 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Cs-134 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Cs-134m 1.0X103 2.7X10-8 1.0X105 2.7X10-6 Cs-135 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Cs-136 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Cs-137 (b) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Cu-64 Copper (29) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Cu-67 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Dy-159 Dysprosium (66) 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Dy-165 1.0X103 2.7X10-8 1.0X106 2.7X10-5
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Dy-166 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Er-169 Erbium (68) 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Er-171 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Eu-147 Europium (63) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Eu-148 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Eu-149 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Eu-150 (short lived) 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Eu-150 (long lived) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Eu-152 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Eu-152m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Eu-154 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Eu-155 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Eu-156 1.0X101 2.7X10-10 1.0X106 2.7X10-5 F-18 Fluorine (9) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Fe-52 Iron (26) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Fe-55 1.0X104 2.7X10-7 1.0X106 2.7X10-5 Fe-59 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Fe-60 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Ga-67 Gallium (31) 1.0X102 2.7X10-9 1.0X106 2.7X10-5
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Ga-68 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Ga-72 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Gd-146 Gadolinium (64) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Gd-148 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Gd-153 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Gd-159 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Ge-68 Germanium (32) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Ge-71 1.0X104 2.7X10-7 1.0X108 2.7X10-3 Ge-77 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Hf-172 Hafnium (72) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Hf-175 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Hf-181 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Hf-182 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Hg-194 Mercury (80) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Hg-195m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Hg-197 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Hg-197m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Hg-203 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Ho-166 Holmium (67) 1.0X103 2.7X10-8 1.0X105 2.7X10-6
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Ho-166m 1.0X101 2.7X10-10 1.0X106 2.7X10-5 I-123 Iodine (53) 1.0X102 2.7X10-9 1.0X107 2.7X10-4 I-124 1.0X101 2.7X10-10 1.0X106 2.7X10-5 I-125 1.0X103 2.7X10-8 1.0X106 2.7X10-5 I-126 1.0X102 2.7X10-9 1.0X106 2.7X10-5 I-129 1.0X102 2.7X10-9 1.0X105 2.7X10-6 I-131 1.0X102 2.7X10-9 1.0X106 2.7X10-5 I-132 1.0X101 2.7X10-10 1.0X105 2.7X10-6 I-133 1.0X101 2.7X10-10 1.0X106 2.7X10-5 I-134 1.0X101 2.7X10-10 1.0X105 2.7X10-6 I-135 1.0X101 2.7X10-10 1.0X106 2.7X10-5 In-111 Indium (49) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 In-113m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 In-114m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 In-115m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Ir-189 Iridium (77) 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Ir-190 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Ir-192 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Ir-194 1.0X102 2.7X10-9 1.0X105 2.7X10-6
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
K-40 Potassium (19) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 K-42 1.0X102 2.7X10-9 1.0X106 2.7X10-5 K-43 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Kr-79 Krypton (36) 1.0X103 2.7X10-8 1.0X105 2.7X10-6 Kr-81 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Kr-85 1.0X105 2.7X10-6 1.0X104 2.7X10-7 Kr-85m 1.0X103 2.7X10-8 1.0X1010 2.7X10-1 Kr-87 1.0X102 2.7X10-9 1.0X109 2.7X10-2 La-137 Lanthanum (57) 1.0X103 2.7X10-8 1.0X107 2.7X10-4 La-140 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Lu-172 Lutetium (71) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Lu-173 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Lu-174 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Lu-174m 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Lu-177 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Mg-28 Magnesium (12) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Mn-52 Manganese (25) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Mn-53 1.0X104 2.7X10-7 1.0X109 2.7X10-2 Mn-54 1.0X101 2.7X10-10 1.0X106 2.7X10-5
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Mn-56 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Mo-93 Molybdenum (42) 1.0X103 2.7X10-8 1.0X108 2.7X10-3 Mo-99 1.0X102 2.7X10-9 1.0X106 2.7X10-5 N-13 Nitrogen (7) 1.0X102 2.7X10-9 1.0X109 2.7X10-2 Na-22 Sodium (11) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Na-24 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Nb-93m Niobium (41) 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Nb-94 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Nb-95 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Nb-97 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Nd-147 Neodymium (60) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Nd-149 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Ni-59 Nickel (28) 1.0X104 2.7X10-7 1.0X108 2.7X10-3 Ni-63 1.0X105 2.7X10-6 1.0X108 2.7X10-3 Ni-65 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Np-235 Neptunium (93) 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Np-236 (short-lived) 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Np-236 (long-lived) 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Np-237 (b) 1.0 2.7X10-11 1.0X103 2.7X10-8
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Np-239 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Os-185 Osmium (76) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Os-191 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Os-191m 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Os-193 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Os-194 1.0X102 2.7X10-9 1.0X105 2.7X10-6 P-32 Phosphorus (15) 1.0X103 2.7X10-8 1.0X105 2.7X10-6 P-33 1.0X105 2.7X10-6 1.0X108 2.7X10-3 Pa-230 Protactinium (91) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Pa-231 1.0 2.7X10-11 1.0X103 2.7X10-8 Pa-233 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Pb-201 Lead (82) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Pb-202 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Pb-203 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Pb-205 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Pb-210 (b) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Pb-212 (b) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Pd-103 Palladium (46) 1.0X103 2.7X10-8 1.0X108 2.7X10-3 Pd-107 1.0X105 2.7X10-6 1.0X108 2.7X10-3
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Pd-109 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Pm-143 Promethium (61) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Pm-144 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Pm-145 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Pm-147 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Pm-148m 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Pm-149 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Pm-151 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Po-210 Polonium (84) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Pr-142 Praseodymium (59) 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Pr-143 1.0X104 2.7X10-7 1.0X106 2.7X10-5 Pt-188 Platinum (78) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Pt-191 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Pt-193 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Pt-193m 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Pt-195m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Pt-197 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Pt-197m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Pu-236 Plutonium (94) 1.0X101 2.7X10-10 1.0X104 2.7X10-7
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Pu-237 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Pu-238 1.0 2.7X10-11 1.0X104 2.7X10-7 Pu-239 1.0 2.7X10-11 1.0X104 2.7X10-7 Pu-240 1.0 2.7X10-11 1.0X103 2.7X10-8 Pu-241 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Pu-242 1.0 2.7X10-11 1.0X104 2.7X10-7 Pu-244 1.0 2.7X10-11 1.0X104 2.7X10-7 Ra-223 (b)
Radium (88) 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Ra-224 (b) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Ra-225 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Ra-226 (b) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Ra-228 (b) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Rb-81 Rubidium (37) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Rb-83 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Rb-84 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Rb-86 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Rb-87 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Rb(nat) 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Re-184 Rhenium (75) 1.0X101 2.7X10-10 1.0X106 2.7X10-5
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Re-184m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Re-186 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Re-187 1.0X106 2.7X10-5 1.0X109 2.7X10-2 Re-188 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Re-189 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Re(nat) 1.0X106 2.7X10-5 1.0X109 2.7X10-2 Rh-99 Rhodium (45) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Rh-101 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Rh-102 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Rh-102m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Rh-103m 1.0X104 2.7X10-7 1.0X108 2.7X10-3 Rh-105 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Rn-222 (b)
Radon (86) 1.0X101 2.7X10-10 1.0X108 2.7X10-3 Ru-97 Ruthenium (44) 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Ru-103 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Ru-105 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Ru-106 (b) 1.0X102 2.7X10-9 1.0X105 2.7X10-6 S-35 Sulfur (16) 1.0X105 2.7X10-6 1.0X108 2.7X10-3 Sb-122 Antimony (51) 1.0X102 2.7X10-9 1.0X104 2.7X10-7
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Sb-124 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Sb-125 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Sb-126 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Sc-44 Scandium (21) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Sc-46 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Sc-47 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Sc-48 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Se-75 Selenium (34) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Se-79 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Si-31 Silicon (14) 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Si-32 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Sm-145 Samarium (62) 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Sm-147 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Sm-151 1.0X104 2.7X10-7 1.0X108 2.7X10-3 Sm-153 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Sn-113 Tin (50) 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Sn-117m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Sn-119m 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Sn-121m 1.0X103 2.7X10-8 1.0X107 2.7X10-4
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Sn-123 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Sn-125 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Sn-126 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Sr-82 Strontium (38) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Sr-85 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Sr-85m 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Sr-87m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Sr-89 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Sr-90 (b) 1.0X102 2.7X10-9 1.0X104 2.7X10-7 Sr-91 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Sr-92 1.0X101 2.7X10-10 1.0X106 2.7X10-5 T(H-3)
Tritium (1) 1.0X106 2.7X10-5 1.0X109 2.7X10-2 Ta-178 (long-lived)
Tantalum (73) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Ta-179 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Ta-182 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Tb-157 Terbium (65) 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Tb-158 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Tb-160 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Tc-95m Technetium (43) 1.0X101 2.7X10-10 1.0X106 2.7X10-5
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Tc-96 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Tc-96m 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Tc-97 1.0X103 2.7X10-8 1.0X108 2.7X10-3 Tc-97m 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Tc-98 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Tc-99 1.0X104 2.7X10-7 1.0X107 2.7X10-4 Tc-99m 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Te-121 Tellurium (52) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Te-121m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Te-123m 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Te-125m 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Te-127 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Te-127m 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Te-129 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Te-129m 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Te-131m 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Te-132 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Th-227 Thorium (90) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Th-228 (b) 1.0 2.7X10-11 1.0X104 2.7X10-7
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Th-229 (b) 1.0 2.7X10-11 1.0X103 2.7X10-8 Th-230 1.0 2.7X10-11 1.0X104 2.7X10-7 Th-231 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Th-232 1.0X101 2.7X10-10 1.0X104 2.7X10-7 Th-234 (b) 1.0X103 2.7X10-8 1.0X105 2.7X10-6 Th (nat) (b) 1.0 2.7X10-11 1.0X103 2.7X10-8 Ti-44 Titanium (22) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 Tl-200 Thallium (81) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Tl-201 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Tl-202 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Tl-204 1.0X104 2.7X10-7 1.0X104 2.7X10-7 Tm-167 Thulium (69) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Tm-170 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Tm-171 1.0X104 2.7X10-7 1.0X108 2.7X10-3 U-230 (fast lung absorption) (b),(d)
Uranium (92) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 U-230 (medium lung absorption) (e) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 U-230 (slow lung absorption) (f) 1.0X101 2.7X10-10 1.0X104 2.7X10-7
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
U-232 (fast lung absorption) (b),(d) 1.0 2.7X10-11 1.0X103 2.7X10-8 U-232 (medium lung absorption) (e) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 U-232 (slow lung absorption) (f) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 U-233 (fast lung absorption) (d) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 U-233 (medium lung absorption) (e) 1.0X102 2.7X10-9 1.0X105 2.7X10-6 U-233 (slow lung absorption) (f) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 U-234 (fast lung absorption) (d) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 U-234 (medium lung absorption) (e) 1.0X102 2.7X10-9 1.0X105 2.7X10-6 U-234 (slow lung absorption) (f) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 U-235 (all lung absorption types)
(b),(d),(e),(f) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 U-236 (fast lung absorption) (d) 1.0X101 2.7X10-10 1.0X104 2.7X10-7
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
U-236 (medium lung absorption) (e) 1.0X102 2.7X10-9 1.0X105 2.7X10-6 U-236 (slow lung absorption) (f) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 U-238 (all lung absorption types)
(b),(d),(e),(f) 1.0X101 2.7X10-10 1.0X104 2.7X10-7 U (nat) (b) 1.0 2.7X10-11 1.0X103 2.7X10-8 U (enriched to 20% or less) (g) 1.0 2.7X10-11 1.0X103 2.7X10-8 U (dep) 1.0 2.7X10-11 1.0X103 2.7X10-8 V-48 Vanadium (23) 1.0X101 2.7X10-10 1.0X105 2.7X10-6 V-49 1.0X104 2.7X10-7 1.0X107 2.7X10-4 W-178 Tungsten (74) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 W-181 1.0X103 2.7X10-8 1.0X107 2.7X10-4 W-185 1.0X104 2.7X10-7 1.0X107 2.7X10-4 W-187 1.0X102 2.7X10-9 1.0X106 2.7X10-5 W-188 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Xe-122 Xenon (54) 1.0X102 2.7X10-9 1.0X109 2.7X10-2 Xe-123 1.0X102 2.7X10-9 1.0X109 2.7X10-2 Xe-127 1.0X103 2.7X10-8 1.0X105 2.7X10-6
Figure: 25 TAC §289.257(ee)(7)
Symbol of radionuclide Element and atomic number Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limit for exempt consignment (Bq)
Activity limit for exempt consignment (Ci)
Xe-131m 1.0X104 2.7X10-7 1.0X104 2.7X10-7 Xe-133 1.0X103 2.7X10-8 1.0X104 2.7X10-7 Xe-135 1.0X103 2.7X10-8 1.0X1010 2.7X10-1 Y-87 Yttrium (39) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Y-88 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Y-90 1.0X103 2.7X10-8 1.0X105 2.7X10-6 Y-91 1.0X103 2.7X10-8 1.0X106 2.7X10-5 Y-91m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Y-92 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Y-93 1.0X102 2.7X10-9 1.0X105 2.7X10-6 Yb-169 Ytterbium (70) 1.0X102 2.7X10-9 1.0X107 2.7X10-4 Yb-175 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Zn-65 Zinc (30) 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Zn-69 1.0X104 2.7X10-7 1.0X106 2.7X10-5 Zn-69m 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Zr-88 Zirconium (40) 1.0X102 2.7X10-9 1.0X106 2.7X10-5 Zr-93 (b) 1.0X103 2.7X10-8 1.0X107 2.7X10-4 Zr-95 1.0X101 2.7X10-10 1.0X106 2.7X10-5 Zr-97 (b) 1.0X101 2.7X10-10 1.0X105 2.7X10-6
Figure: 25 TAC §289.257(ee)(7) a[Reserved]
b Parent nuclides and their progeny included in secular equilibrium are listed in the following:
Sr-90 Y-90 Zr-93 Nb-93m Zr-97 Nb-97 Ru-106 Rh-106 Cs-137 Ba-137m Ce-144 Pr-144 Ba-140 La-140 Bi-212 Tl-208 (0.36), Po-212 (0.64)
Pb-210 Bi-210, Po-210 Pb-212 Bi-212, Tl-208 (0.36), Po-212 (0.64)
Rn-222 Po-218, Pb-214, Bi-214, Po-214 Ra-223 Rn-219, Po-215, Pb-211, Bi-211, Tl-207 Ra-224 Rn-220, Po-216, Pb-212, Bi-212, Tl-208(0.36), Po-212 (0.64)
Ra-226 Rn-222, Po-218, Pb-214, Bi-214, Po-214, Pb-210, Bi-210, Po-210 Ra-228 Ac-228 Th-228 Ra-224, Rn-220, Po-216, Pb-212, Bi-212, Tl-208 (0.36), Po-212 (0.64)
Th-229 Ra-225, Ac-225, Fr-221, At-217, Bi-213, Po-213, Pb-209 Th-nat Ra-228, Ac-228, Th-228, Ra-224, Rn-220, Po-216, Pb-212, Bi-212, Tl-208 0.36), Po-212 (0.64)
Th-234 Pa-234m U-230 Th-226, Ra-222, Rn-218, Po-214 U-232 Th-228, Ra-224, Rn-220, Po-216, Pb-212, Bi-212, Tl-208 (0.36), Po-212 (0.64)
U-235 Th-231 U-238 Th-234, Pa-234m U-nat Th-234, Pa-234m, U-234, Th-230, Ra-226, Rn-222, Po-218, Pb-214, Bi-214, Po-214, Pb-210, Bi-210, Po-210 U-240 Np-240m Np-237 Pa-233 Am-242m Am-242 Am-243 Np-239
Figure: 25 TAC §289.257(ee)(7) c[Reserved]
d These values apply only to compounds of uranium that take the chemical form of UF6, UO2F2 and UO2(NO3)2 in both normal and accident conditions of transport.
e These values apply only to compounds of uranium that take the chemical form of UO3, UF4, UCl4 and hexavalent compounds in both normal and accident conditions of transport.
f These values apply to all compounds of uranium other than those specified in notes (d) and (e) of this table.
g These values apply to unirradiated uranium only.
THIS PORTION OF THE PAGE LEFT INTENTIONALLY BLANK
Figure: 25 TAC §289.257(ee)(8)
Table 257-5: General Values For A1 And A2 Contents A1 A2 Activity concentration for exempt material (Bq/g)
Activity concentration for exempt material (Ci/g)
Activity limits for exempt consignments (Bq)
Activity limits for exempt consignments (Ci)
(TBq)
(Ci)
(TBq)
(Ci)
Only beta or gamma emitting radionuclides are known to be present 1 x 10-1 2.7 x 100 2 x 10 -2 5.4 x 10-1 1 x 101 2.7 x10-10 1 x 104 2.7 x10-7 Alpha emitting nuclides, but no neutron emitters, are known to be presenta 2 x 10-1 5.4 x 100 9 x 10-5 2.4 x 10-3 1 x 10-1 2.7 x10-12 1 x 103 2.7 x10-8 Neutron emitting nuclides are known to be present or no relevant data are available 1 x 10-3 2.7 x 10-2 9 x 10-5 2.4 x 10-3 1 x 10-1 2.7 x 10-12 1 x 103 2.7 x 10-8 a If beta or gamma emitting nuclides are known to be present, the A1 value of 0.1 TBq (2.7 Ci) should be used.